An electrical grid is an interconnected network for electricity delivery from producers to consumers. Electrical grids vary in size and can cover whole countries or continents. It consists of:[1]

General layout of electricity networks. Voltages and depictions of electrical lines are typical for Germany and other European systems.

Grids are nearly always synchronous, meaning all distribution areas operate with three phase alternating current (AC) frequencies synchronized (so that voltage swings occur at almost the same time). This allows transmission of AC power throughout the area, connecting a large number of electricity generators and consumers and potentially enabling more efficient electricity markets and redundant generation.

The combined transmission and distribution network is part of electricity delivery, known as the "power grid" in North America, or just "the grid." In the United Kingdom, India, Tanzania, Myanmar, Malaysia and New Zealand, the network is known as the National Grid.

Although electrical grids are widespread, as of 2016, 1.4 billion people worldwide were not connected to an electricity grid.[2] As electrification increases, the number of people with access to grid electricity is growing. About 840 million people (mostly in Africa), which is ca. 11% of the World's population, had no access to grid electricity in 2017, down from 1.2 billion in 2010.[3]

Electrical grids can be prone to malicious intrusion or attack; thus, there is a need for electric grid security. Also as electric grids modernize and introduce computer technology, cyber threats start to become a security risk.[4] Particular concerns relate to the more complex computer systems needed to manage grids.[5]

History edit

Early electric energy was produced near the device or service requiring that energy. In the 1880s, electricity competed with steam, hydraulics, and especially coal gas. Coal gas was first produced on customer's premises but later evolved into gasification plants that enjoyed economies of scale. In the industrialized world, cities had networks of piped gas, used for lighting. But gas lamps produced poor light, wasted heat, made rooms hot and smokey, and gave off hydrogen and carbon monoxide. They also posed a fire hazard. In the 1880s electric lighting soon became advantageous compared to gas lighting.

Electric utility companies established central stations to take advantage of economies of scale and moved to centralized power generation, distribution, and system management.[6] After the war of the currents was settled in favor of AC power, with long-distance power transmission it became possible to interconnect stations to balance the loads and improve load factors. Historically, transmission and distribution lines were owned by the same company, but starting in the 1990s, many countries have liberalized the regulation of the electricity market in ways that have led to the separation of the electricity transmission business from the distribution business.[7]

In the United Kingdom, Charles Merz, of the Merz & McLellan consulting partnership, built the Neptune Bank Power Station near Newcastle upon Tyne in 1901,[8] and by 1912 had developed into the largest integrated power system in Europe.[9] Merz was appointed head of a parliamentary committee and his findings led to the Williamson Report of 1918, which in turn created the Electricity (Supply) Act 1919. The bill was the first step towards an integrated electricity system. The Electricity (Supply) Act 1926 led to the setting up of the National Grid.[10] The Central Electricity Board standardized the nation's electricity supply and established the first synchronized AC grid, running at 132 kilovolts and 50 hertz. This started operating as a national system, the National Grid, in 1938.

In France, electrification began in the 1900s, with 700 communes in 1919, and 36,528 in 1938. At the same time, these close networks began to interconnect: Paris in 1907 at 12 kV, the Pyrénées in 1923 at 150 kV, and finally almost all of the country interconnected by 1938 at 220 kV. In 1946, the grid was the world's most dense. That year the state nationalised the industry, by uniting the private companies as Électricité de France. The frequency was standardised at 50 Hz, and the 225 kV network replaced 110 kV and 120 kV. Since 1956, service voltage has been standardised at 220/380 V, replacing the previous 127/220 V. During the 1970s, the 400 kV network, the new European standard, was implemented.

In the United States in the 1920s, utilities formed joint-operations to share peak load coverage and backup power. In 1934, with the passage of the Public Utility Holding Company Act (USA), electric utilities were recognized as public goods of importance and were given outlined restrictions and regulatory oversight of their operations. The Energy Policy Act of 1992 required transmission line owners to allow electric generation companies open access to their network[6][11] and led to a restructuring of how the electric industry operated in an effort to create competition in power generation. No longer were electric utilities built as vertical monopolies, where generation, transmission and distribution were handled by a single company. Now, the three stages could be split among various companies, in an effort to provide fair access to high voltage transmission.[12]: 21  The Energy Policy Act of 2005 allowed incentives and loan guarantees for alternative energy production and advance innovative technologies that avoided greenhouse emissions.

Soviet Union was the first country to implement a large-scale electrification program: in 10 years between 1930 and 1940 the country's electricity output increased from 2.6 billion kWh to 13.5 billion kWh (see GOELRO). The USSR continued to pursue electrification and grid intergration with its ally countries. World's largest electric grid "Mir" (see ru:Мир (энергосистема)) encompassed 9 countries from East Germany to Mongolia between ca. 1960 and 1990. It achieved power of 400,000 MW.

In China, electrification began in the 1950s.[13] In August 1961, the electrification of the Baoji-Fengzhou section of the Baocheng Railway was completed and delivered for operation, becoming China's first electrified railway.[14] From 1958 to 1998, China's electrified railway reached 6,200 miles (10,000 kilometres).[15] As of the end of 2017, this number has reached 54,000 miles (87,000 kilometres).[16] In the current railway electrification system of China, State Grid Corporation of China 2021-12-21 at the Wayback Machine is an important power supplier. In 2019, it completed the power supply project of China's important electrified railways in its operating areas, such as Jingtong Railway, Haoji Railway, Zhengzhou–Wanzhou high-speed railway, et cetera, providing power supply guarantee for 110 traction stations, and its cumulative power line construction length reached 6,586 kilometres.[17]

Components edit

Generation edit

 
Turbo generator
 
Diagram of an electric power system, generation system in red

Electricity generation is the process of generating electric power from sources of primary energy typically at power stations. Usually this is done with electromechanical generators driven by heat engines or the kinetic energy of water or wind. Other energy sources include solar photovoltaics and geothermal power.

The sum of the power outputs of generators on the grid is the production of the grid, typically measured in gigawatts (GW).

Transmission edit

 
500 kV Three-phase electric power Transmission Lines at Grand Coulee Dam; four circuits are shown; two additional circuits are obscured by trees on the right; the entire 7079 MW generation capacity of the dam is accommodated by these six circuits.

Electric power transmission is the bulk movement of electrical energy from a generating site, via a web of interconnected lines, to an electrical substation, from which is connected to the distribution system. This networked system of connections is distinct from the local wiring between high-voltage substations and customers.

Because the power is often generated far from where it is consumed, the transmission system can cover great distances. For a given amount of power, transmission efficiency is greater at higher voltages and lower currents. Therefore, voltages are stepped up at the generating station, and stepped down at local substations for distribution to customers.

Most transmission is three-phase. Three phase, compared to single phase, can deliver much more power for a given amount of wire, since the neutral and ground wires are shared.[18] Further, three-phase generators and motors are more efficient than their single-phase counterparts.

However, for conventional conductors one of the main losses are resistive losses which are a square law on current, and depend on distance. High voltage AC transmission lines can lose 1-4% per hundred miles.[19] However, high-voltage direct current can have half the losses of AC. Over very long distances, these efficiencies can offset the additional cost of the required AC/DC converter stations at each end.

 
Network diagram of a high voltage transmission system, showing the interconnection between the different voltage levels. This diagram depicts the electrical structure[20] of the network, rather than its physical geography.

Transmission networks are complex with redundant pathways. The physical layout is often forced by what land is available and its geology. Most transmission grids offer the reliability that more complex mesh networks provide. Redundancy allows line failures to occur and power is simply rerouted while repairs are done.

Substations edit

Substations may perform many different functions but usually transform voltage from low to high (step up) and from high to low (step down). Between the generator and the final consumer, the voltage may be transformed several times.[21]

The three main types of substations, by function, are:[22]

  • Step-up substation: these use transformers to raise the voltage coming from the generators and power plants so that power can be transmitted long distances more efficiently, with smaller currents.
  • Step-down substation: these transformers lower the voltage coming from the transmission lines which can be used in industry or sent to a distribution substation.
  • Distribution substation: these transform the voltage lower again for the distribution to end users.

Aside from transformers, other major components or functions of substations include:

  • Circuit breakers: used to automatically break a circuit and isolate a fault in the system.[23]
  • Switches: to control the flow of electricity, and isolate equipment.[24]
  • The substation busbar: typically a set of three conductors, one for each phase of current. The substation is organized around the buses, and they are connected to incoming lines, transformers, protection equipment, switches, and the outgoing lines.[23]
  • Lightning arresters
  • Capacitors for power factor correction
  • Synchronous condensers for power factor correction and grid stability

Electric power distribution edit

Distribution is the final stage in the delivery of power; it carries electricity from the transmission system to individual consumers. Substations connect to the transmission system and lower the transmission voltage to medium voltage ranging between kV and 35 kV. Primary distribution lines carry this medium voltage power to distribution transformers located near the customer's premises. Distribution transformers again lower the voltage to the utilization voltage. Customers demanding a much larger amount of power may be connected directly to the primary distribution level or the subtransmission level.[25]

Distribution networks are divided into two types, radial or network.[26]

In cities and towns of North America, the grid tends to follow the classic radially fed design. A substation receives its power from the transmission network, the power is stepped down with a transformer and sent to a bus from which feeders fan out in all directions across the countryside. These feeders carry three-phase power, and tend to follow the major streets near the substation. As the distance from the substation grows, the fanout continues as smaller laterals spread out to cover areas missed by the feeders. This tree-like structure grows outward from the substation, but for reliability reasons, usually contains at least one unused backup connection to a nearby substation. This connection can be enabled in case of an emergency, so that a portion of a substation's service territory can be alternatively fed by another substation.

Storage edit

 
Simplified electrical grid with energy storage
 
Simplified grid energy flow with and without idealized energy storage for the course of one day

Grid energy storage (also called large-scale energy storage) is a collection of methods used for energy storage on a large scale within an electrical power grid. Electrical energy is stored during times when electricity is plentiful and inexpensive (especially from intermittent power sources such as renewable electricity from wind power, tidal power and solar power) or when demand is low, and later returned to the grid when demand is high, and electricity prices tend to be higher.

As of 2020, the largest form of grid energy storage is dammed hydroelectricity, with both conventional hydroelectric generation as well as pumped storage hydroelectricity.

Developments in battery storage have enabled commercially viable projects to store energy during peak production and release during peak demand, and for use when production unexpectedly falls giving time for slower responding resources to be brought online.

Two alternatives to grid storage are the use of peaking power plants to fill in supply gaps and demand response to shift load to other times.

Functionalities edit

Demand edit

The demand, or load on an electrical grid is the total electrical power being removed by the users of the grid.

The graph of the demand over time is called the demand curve.

Baseload is the minimum load on the grid over any given period, peak demand is the maximum load. Historically, baseload was commonly met by equipment that was relatively cheap to run, that ran continuously for weeks or months at a time, but globally this is becoming less common. The extra peak demand requirements are sometimes produced by expensive peaking plants that are generators optimised to come on-line quickly but these too are becoming less common.

However, if the demand of electricity exceed the capacity of a local power grid, it will cause safety issue like burning out.[27]

Voltage edit

Grids are designed to supply electricity to their customers at largely constant voltages. This has to be achieved with varying demand, variable reactive loads, and even nonlinear loads, with electricity provided by generators and distribution and transmission equipment that are not perfectly reliable.[28] Often grids use tap changers on transformers near to the consumers to adjust the voltage and keep it within specification.

Frequency edit

In a synchronous grid all the generators must run at the same frequency, and must stay very nearly in phase with each other and the grid. Generation and consumption must be balanced across the entire grid, because energy is consumed as it is produced. For rotating generators, a local governor regulates the driving torque, maintaining almost constant rotation speed as loading changes. Energy is stored in the immediate short term by the rotational kinetic energy of the generators.

Although the speed is kept largely constant, small deviations from the nominal system frequency are very important in regulating individual generators and are used as a way of assessing the equilibrium of the grid as a whole. When the grid is lightly loaded the grid frequency runs above the nominal frequency, and this is taken as an indication by Automatic Generation Control systems across the network that generators should reduce their output. Conversely, when the grid is heavily loaded, the frequency naturally slows, and governors adjust their generators so that more power is output (droop speed control). When generators have identical droop speed control settings it ensures that multiple parallel generators with the same settings share load in proportion to their rating.

In addition, there's often central control, which can change the parameters of the AGC systems over timescales of a minute or longer to further adjust the regional network flows and the operating frequency of the grid.

For timekeeping purposes, the nominal frequency will be allowed to vary in the short term, but is adjusted to prevent line-operated clocks from gaining or losing significant time over the course of a whole 24 hour period.

An entire synchronous grid runs at the same frequency, neighbouring grids would not be synchronised even if they run at the same nominal frequency. High-voltage direct current lines or variable-frequency transformers can be used to connect two alternating current interconnection networks which are not synchronized with each other. This provides the benefit of interconnection without the need to synchronize an even wider area. For example, compare the wide area synchronous grid map of Europe with the map of HVDC lines.

Capacity and firm capacity edit

The sum of the maximum power outputs (nameplate capacity) of the generators attached to an electrical grid might be considered to be the capacity of the grid.

However, in practice, they are never run flat out simultaneously. Typically, some generators are kept running at lower output powers (spinning reserve) to deal with failures as well as variation in demand. In addition generators can be off-line for maintenance or other reasons, such as availability of energy inputs (fuel, water, wind, sun etc.) or pollution constraints.

Firm capacity is the maximum power output on a grid that is immediately available over a given time period, and is a far more useful figure.

Production edit

Most grid codes specify that the load is shared between the generators in merit order according to their marginal cost (i.e. cheapest first) and sometimes their environmental impact. Thus cheap electricity providers tend to be run flat out almost all the time, and the more expensive producers are only run when necessary.

Handling failure edit

Failures are usually associated with generators or power transmission lines tripping circuit breakers due to faults leading to a loss of generation capacity for customers, or excess demand. This will often cause the frequency to reduce, and the remaining generators will react and together attempt to stabilize above the minimum. If that is not possible then a number of scenarios can occur.

A large failure in one part of the grid — unless quickly compensated for — can cause current to re-route itself to flow from the remaining generators to consumers over transmission lines of insufficient capacity, causing further failures. One downside to a widely connected grid is thus the possibility of cascading failure and widespread power outage. A central authority is usually designated to facilitate communication and develop protocols to maintain a stable grid. For example, the North American Electric Reliability Corporation gained binding powers in the United States in 2006, and has advisory powers in the applicable parts of Canada and Mexico. The U.S. government has also designated National Interest Electric Transmission Corridors, where it believes transmission bottlenecks have developed.

Brownout edit

 
A brownout near Tokyo Tower in Tokyo, Japan

A brownout is an intentional or unintentional drop in voltage in an electrical power supply system. Intentional brownouts are used for load reduction in an emergency.[29] The reduction lasts for minutes or hours, as opposed to short-term voltage sag (or dip). The term brownout comes from the dimming experienced by incandescent lighting when the voltage sags. A voltage reduction may be an effect of disruption of an electrical grid, or may occasionally be imposed in an effort to reduce load and prevent a power outage, known as a blackout.[30]

Blackout edit

A power outage (also called a power cut, a power out, a power blackout, power failure or a blackout) is a loss of the electric power to a particular area.

Power failures can be caused by faults at power stations, damage to electric transmission lines, substations or other parts of the distribution system, a short circuit, cascading failure, fuse or circuit breaker operation, and human error.

Power failures are particularly critical at sites where the environment and public safety are at risk. Institutions such as hospitals, sewage treatment plants, mines, shelters and the like will usually have backup power sources such as standby generators, which will automatically start up when electrical power is lost. Other critical systems, such as telecommunication, are also required to have emergency power. The battery room of a telephone exchange usually has arrays of lead–acid batteries for backup and also a socket for connecting a generator during extended periods of outage.

Load shedding edit

Electrical generation and transmission systems may not always meet peak demand requirements— the greatest amount of electricity required by all utility customers within a given region. In these situations, overall demand must be lowered, either by turning off service to some devices or cutting back the supply voltage (brownouts), in order to prevent uncontrolled service disruptions such as power outages (widespread blackouts) or equipment damage. Utilities may impose load shedding on service areas via targeted blackouts, rolling blackouts or by agreements with specific high-use industrial consumers to turn off equipment at times of system-wide peak demand.

Black start edit

 
Toronto during the Northeast blackout of 2003, which required black-starting of generating stations.

A black start is the process of restoring an electric power station or a part of an electric grid to operation without relying on the external electric power transmission network to recover from a total or partial shutdown.[31]

Normally, the electric power used within the plant is provided from the station's own generators. If all of the plant's main generators are shut down, station service power is provided by drawing power from the grid through the plant's transmission line. However, during a wide-area outage, off-site power from the grid is not available. In the absence of grid power, a so-called black start needs to be performed to bootstrap the power grid into operation.

To provide a black start, some power stations have small diesel generators, normally called the black start diesel generator (BSDG), which can be used to start larger generators (of several megawatts capacity), which in turn can be used to start the main power station generators. Generating plants using steam turbines require station service power of up to 10% of their capacity for boiler feedwater pumps, boiler forced-draft combustion air blowers, and for fuel preparation. It is uneconomical to provide such a large standby capacity at each station, so black-start power must be provided over designated tie lines from another station. Often hydroelectric power plants are designated as the black-start sources to restore network interconnections. A hydroelectric station needs very little initial power to start (just enough to open the intake gates and provide excitation current to the generator field coils), and can put a large block of power on line very quickly to allow start-up of fossil-fuel or nuclear stations. Certain types of combustion turbine can be configured for black start, providing another option in places without suitable hydroelectric plants.[32] In 2017 a utility in Southern California has successfully demonstrated the use of a battery energy storage system to provide a black start, firing up a combined cycle gas turbine from an idle state.[33]

Scale edit

Microgrid edit

A microgrid is a local grid that is usually part of the regional wide-area synchronous grid but which can disconnect and operate autonomously.[34] It might do this in times when the main grid is affected by outages. This is known as islanding, and it might run indefinitely on its own resources.

Compared to larger grids, microgrids typically use a lower voltage distribution network and distributed generators.[35] Microgrids may not only be more resilient, but may be cheaper to implement in isolated areas.

A design goal is that a local area produces all of the energy it uses.[34]

Example implementations include:

  • Hajjah and Lahj, Yemen: community-owned solar microgrids.[36]
  • Île d'Yeu pilot program: sixty-four solar panels with a peak capacity of 23.7 kW on five houses and a battery with a storage capacity of 15 kWh.[37][38]
  • Les Anglais, Haiti:[39] includes energy theft detection.[40]
  • Mpeketoni, Kenya: a community-based diesel-powered micro-grid system.[41]
  • Stone Edge Farm Winery: micro-turbine, fuel-cell, multiple battery, hydrogen electrolyzer, and PV enabled winery in Sonoma, California.[42][43]

Wide area synchronous grid edit

A wide area synchronous grid, also known as an "interconnection" in North America, directly connects many generators delivering AC power with the same relative frequency to many consumers. For example, there are four major interconnections in North America (the Western Interconnection, the Eastern Interconnection, the Quebec Interconnection and the Texas Interconnection). In Europe one large grid connects most of continental Europe.

A wide area synchronous grid (also called an "interconnection" in North America) is an electrical grid at a regional scale or greater that operates at a synchronized frequency and is electrically tied together during normal system conditions. These are also known as synchronous zones, the largest of which is the synchronous grid of Continental Europe (ENTSO-E) with 667 gigawatts (GW) of generation, and the widest region served being that of the IPS/UPS system serving countries of the former Soviet Union. Synchronous grids with ample capacity facilitate electricity market trading across wide areas. In the ENTSO-E in 2008, over 350,000 megawatt hours were sold per day on the European Energy Exchange (EEX).[44]

Each of the interconnects in North America are run at a nominal 60 Hz, while those of Europe run at 50 Hz. Neighbouring interconnections with the same frequency and standards can be synchronized and directly connected to form a larger interconnection, or they may share power without synchronization via high-voltage direct current power transmission lines (DC ties), or with variable-frequency transformers (VFTs), which permit a controlled flow of energy while also functionally isolating the independent AC frequencies of each side.

The benefits of synchronous zones include pooling of generation, resulting in lower generation costs; pooling of load, resulting in significant equalizing effects; common provisioning of reserves, resulting in cheaper primary and secondary reserve power costs; opening of the market, resulting in possibility of long-term contracts and short term power exchanges; and mutual assistance in the event of disturbances.[45]

One disadvantage of a wide-area synchronous grid is that problems in one part can have repercussions across the whole grid. For example, in 2018 Kosovo used more power than it generated due to a dispute with Serbia, leading to the phase across the whole synchronous grid of Continental Europe lagging behind what it should have been. The frequency dropped to 49.996 Hz. This caused certain kinds of clocks to become six minutes slow.[46]

Super grid edit

 
One conceptual plan of a super grid linking renewable sources across North Africa, the Middle East and Europe. (DESERTEC)[47]

A super grid or supergrid is a wide-area transmission network that is intended to make possible the trade of high volumes of electricity across great distances. It is sometimes also referred to as a mega grid. Super grids can support a global energy transition by smoothing local fluctuations of wind energy and solar energy. In this context they are considered as a key technology to mitigate global warming. Super grids typically use High-voltage direct current (HVDC) to transmit electricity long distances. The latest generation of HVDC power lines can transmit energy with losses of only 1.6% per 1000 km.[48]

Electric utilities between regions are many times interconnected for improved economy and reliability. Electrical interconnectors allow for economies of scale, allowing energy to be purchased from large, efficient sources. Utilities can draw power from generator reserves from a different region to ensure continuing, reliable power and diversify their loads. Interconnection also allows regions to have access to cheap bulk energy by receiving power from different sources. For example, one region may be producing cheap hydro power during high water seasons, but in low water seasons, another area may be producing cheaper power through wind, allowing both regions to access cheaper energy sources from one another during different times of the year. Neighboring utilities also help others to maintain the overall system frequency and also help manage tie transfers between utility regions.[12]

Electricity Interconnection Level (EIL) of a grid is the ratio of the total interconnector power to the grid divided by the installed production capacity of the grid. Within the EU, it has set a target of national grids reaching 10% by 2020, and 15% by 2030.[49]

Trends edit

Demand response edit

Demand response is a grid management technique where retail or wholesale customers are requested or incentivised either electronically or manually to reduce their load. Currently, transmission grid operators use demand response to request load reduction from major energy users such as industrial plants.[50] Technologies such as smart metering can encourage customers to use power when electricity is plentiful by allowing for variable pricing.

Aging infrastructure edit

Despite the novel institutional arrangements and network designs of the electrical grid, its power delivery infrastructures suffer aging across the developed world. Contributing factors to the current state of the electric grid and its consequences include:

  • Aging equipment – older equipment has higher failure rates, leading to customer interruption rates affecting the economy and society; also, older assets and facilities lead to higher inspection maintenance costs and further repair and restoration costs.
  • Obsolete system layout – older areas require serious additional substation sites and rights-of-way that cannot be obtained in the current area and are forced to use existing, insufficient facilities.
  • Outdated engineering – traditional tools for power delivery planning and engineering are ineffective in addressing current problems of aged equipment, obsolete system layouts, and modern deregulated loading levels.
  • Old cultural value – planning, engineering, operating of system using concepts and procedures that worked in vertically integrated industry exacerbate the problem under a deregulated industry.[51]

Distributed generation edit

With everything interconnected, and open competition occurring in a free market economy, it starts to make sense to allow and even encourage distributed generation (DG). Smaller generators, usually not owned by the utility, can be brought on-line to help supply the need for power. The smaller generation facility might be a home-owner with excess power from their solar panel or wind turbine. It might be a small office with a diesel generator. These resources can be brought on-line either at the utility's behest, or by owner of the generation in an effort to sell electricity. Many small generators are allowed to sell electricity back to the grid for the same price they would pay to buy it.

As the 21st century progresses, the electric utility industry seeks to take advantage of novel approaches to meet growing energy demand. Utilities are under pressure to evolve their classic topologies to accommodate distributed generation. As generation becomes more common from rooftop solar and wind generators, the differences between distribution and transmission grids will continue to blur. In July 2017 the CEO of Mercedes-Benz said that the energy industry needs to work better with companies from other industries to form a "total ecosystem", to integrate central and distributed energy resources (DER) to give customers what they want. The electrical grid was originally constructed so that electricity would flow from power providers to consumers. However, with the introduction of DER, power needs to flow both ways on the electric grid, because customers may have power sources such as solar panels.[52]

Smart grid edit

The smart grid would be an enhancement of the 20th century electrical grid, using two-way communications and distributed so-called intelligent devices. Two-way flows of electricity and information could improve the delivery network. Research is mainly focused on three systems of a smart grid – the infrastructure system, the management system, and the protection system.[53]

The infrastructure system is the energy, information, and communication infrastructure underlying of the smart grid that supports:

  • Advanced electricity generation, delivery, and consumption
  • Advanced information metering, monitoring, and management
  • Advanced communication technologies

A smart grid would allow the power industry to observe and control parts of the system at higher resolution in time and space.[54] One of the purposes of the smart grid is real time information exchange to make operation as efficient as possible. It would allow management of the grid on all time scales from high-frequency switching devices on a microsecond scale, to wind and solar output variations on a minute scale, to the future effects of the carbon emissions generated by power production on a decade scale.

The management system is the subsystem in smart grid that provides advanced management and control services. Most of the existing works aim to improve energy efficiency, demand profile, utility, cost, and emission, based on the infrastructure by using optimization, machine learning, and game theory. Within the advanced infrastructure framework of smart grid, more and more new management services and applications are expected to emerge and eventually revolutionize consumers' daily lives.

The protection system of a smart grid provides grid reliability analysis, failure protection, and security and privacy protection services. While the additional communication infrastructure of a smart grid provides additional protective and security mechanisms, it also presents a risk of external attack and internal failures. In a report on cyber security of smart grid technology first produced in 2010, and later updated in 2014, the US National Institute of Standards and Technology pointed out that the ability to collect more data about energy use from customer smart meters also raises major privacy concerns, since the information stored at the meter, which is potentially vulnerable to data breaches, can be mined for personal details about customers.[55]

In the U.S., the Energy Policy Act of 2005 and Title XIII of the Energy Independence and Security Act of 2007 are providing funding to encourage smart grid development. The objective is to enable utilities to better predict their needs, and in some cases involve consumers in a time-of-use tariff. Funds have also been allocated to develop more robust energy control technologies.[56][57]

Grid defection edit

As there is some resistance in the electric utility sector to the concepts of distributed generation with various renewable energy sources and microscale cogen units, several authors have warned that mass-scale grid defection[definition needed] is possible because consumers can produce electricity using off grid systems primarily made up of solar photovoltaic technology.[58][59][60]

The Rocky Mountain Institute has proposed that there may be widescale grid defection.[61] This is backed up by studies in the Midwest.[62] However, the paper points out that grid defection may be less likely in countries like Germany which have greater power demands in winter.[63]

See also edit

References edit

  1. ^ Kaplan, S. M. (2009). Smart Grid. Electrical Power Transmission: Background and Policy Issues. The Capital.Net, Government Series. Pp. 1-42.
  2. ^ Overland, Indra (1 April 2016). "Energy: The missing link in globalization". Energy Research & Social Science. 14: 122–130. doi:10.1016/j.erss.2016.01.009. from the original on 5 February 2018. [...] if all countries in the world were to make do with their own resources, there would be even more energy poverty in the world than there is now. Currently, 1.4 billion people are not connected to an electricity grid [...]
  3. ^ Odarno, Lily (14 August 2019). "Closing Sub-Saharan Africa's Electricity Access Gap: Why Cities Must Be Part of the Solution". {{cite journal}}: Cite journal requires |journal= (help)
  4. ^ Douris, Constance. "As Cyber Threats To The Electric Grid Rise, Utilities And Regulators Seek Solutions". Forbes. Retrieved 27 September 2018.
  5. ^ Overland, Indra (1 March 2019). "The geopolitics of renewable energy: Debunking four emerging myths". Energy Research & Social Science. 49: 36–40. doi:10.1016/j.erss.2018.10.018. ISSN 2214-6296.
  6. ^ a b Borberly, A. and Kreider, J. F. (2001). Distributed Generation: The Power Paradigm for the New Millennium. CRC Press, Boca Raton, FL. 400 pgs.
  7. ^ "A Primer on Electric Utilities, Deregulation, and Restructuring of U.S. Electricity Markets" (PDF). United States Department of Energy Federal Energy Management Program (FEMP). May 2002. Retrieved 30 October 2018. {{cite journal}}: Cite journal requires |journal= (help)
  8. ^ Mr Alan Shaw (29 September 2005). "Kelvin to Weir, and on to GB SYS 2005" (PDF). Royal Society of Edinburgh. (PDF) from the original on 4 March 2009.
  9. ^ . North Northumberland Online. Archived from the original on 2016-04-12. Retrieved 2013-10-06.
  10. ^ . The National Trust. Archived from the original on 29 June 2011.
  11. ^ Mazer, A. (2007). Electric Power Planning for Regulated and Deregulated Markets. John, Wiley, and Sons, Inc., Hoboken, NJ. 313pgs.
  12. ^ a b . (2001). Glover J. D., Sarma M. S., Overbye T. J. (2010) Power System and Analysis 5th Edition. Cengage Learning. Pg 10.
  13. ^ People's Republic of China Year Book. Xinhua Publishing House. 1989. p. 190.
  14. ^ China Report: Economic affairs. Foreign Broadcast Information Service, Joint Publications Research Service. 1984. p. 54.
  15. ^ . Xinhuanet.com. 3 October 2018. Archived from the original on 18 October 2018.
  16. ^ Avishek G Dastidar (13 September 2018). "After initial questions, government clears 100% Railways electrification". The Indian Express.
  17. ^ . National Development and Reform Commission. 6 January 2020. Archived from the original on 3 March 2021. Retrieved 24 June 2020.
  18. ^ Sajip, Jahnavi. "Why Do We Use Three-Phase Power?". www.ny-engineers.com. Retrieved 22 April 2021.
  19. ^ (PDF). www.aep.com. Archived from the original (PDF) on 4 June 2011. Retrieved 11 January 2022.{{cite web}}: CS1 maint: archived copy as title (link)
  20. ^ Cuffe, Paul; Keane, Andrew (2017). "Visualizing the Electrical Structure of Power Systems". IEEE Systems Journal. 11 (3): 1810–1821. Bibcode:2017ISysJ..11.1810C. doi:10.1109/JSYST.2015.2427994. hdl:10197/7108. ISSN 1932-8184. S2CID 10085130.
  21. ^ "The basic things about substations you MUST know in the middle of the night!". EEP - Electrical Engineering Portal. 9 January 2019. Retrieved 23 April 2021.
  22. ^ "Electrical substation". energyeducation.ca. University of Calgary. Retrieved 23 April 2021.
  23. ^ a b Hayes, Brian (2005). Infrastructure : a field guide to the industrial landscape (1st ed.). New York: W.W. Norton. ISBN 0-393-05997-9.
  24. ^ Hillhouse, Grady. "How Do Substations Work?". Practical Engineering. Retrieved 23 April 2021.
  25. ^ "How Power Grids Work". HowStuffWorks. April 2000. Retrieved 18 March 2016.
  26. ^ Sallam, Abdelhay A. & Malik, Om P. (May 2011). Electric Distribution Systems. IEEE Computer Society Press. p. 21. ISBN 9780470276822.
  27. ^ Wang, Yingcheng; Gladwin, Daniel (January 2021). "Power Management Analysis of a Photovoltaic and Battery Energy Storage-Based Smart Electrical Car Park Providing Ancillary Grid Services". Energies. 14 (24): 8433. doi:10.3390/en14248433. ISSN 1996-1073.
  28. ^ "Archived copy" (PDF). (PDF) from the original on 8 May 2018. Retrieved 28 August 2017.{{cite web}}: CS1 maint: archived copy as title (link)
  29. ^ Steven Warren Blume Electric power system basics: for the nonelectrical professional. John Wiley & Sons, 2007 ISBN 0470129875 p. 199
  30. ^ Alan Wyatt, Electric Power Challenges and Choices, The Book Press Limited, Toronto, 1986 ISBN 0-920650-00-7 page 63
  31. ^ Knight, U.G. Power Systems in Emergencies - From Contingency Planning to Crisis Management John Wiley & Sons 2001 ISBN 978-0-471-49016-6 section 7.5 The 'Black Start' Situation
  32. ^ Philip P. Walsh, Paul Fletcher Gas turbine performance, John Wiley and Sons, 2004 ISBN 0-632-06434-X, page 486
  33. ^ "California battery's black start capability hailed as 'major accomplishment in the energy industry'". 17 May 2017.
  34. ^ a b "How Microgrids Work". Energy.gov. Retrieved 19 April 2021.
  35. ^ Khaitan, Siddhartha Kumar; Venkatraman, Ramakrishnan. "A Survey of Techniques for Designing and Managing Microgrids". Retrieved 19 April 2021.
  36. ^ . Archived from the original on 2021-05-04. Retrieved 2021-04-19.
  37. ^ Spaes, Joel (3 July 2020). "Harmon'Yeu, première communauté énergétique à l'Île d'Yeu, signée Engie". www.pv-magazine.fr. Retrieved 27 January 2021.
  38. ^ Wakim, Nabil (16 December 2020). "A L'Île-d'Yeu, soleil pour tous… ou presque". www.lemonde.fr. Retrieved 27 January 2021.
  39. ^ Buevich, Maxim; Schnitzer, Dan; Escalada, Tristan; Jacquiau-Chamski, Arthur; Rowe, Anthony (2014). "Fine-grained remote monitoring, control and pre-paid electrical service in rural microgrids". IPSN-14 Proceedings of the 13th International Symposium on Information Processing in Sensor Networks. pp. 1–11. doi:10.1109/IPSN.2014.6846736. ISBN 978-1-4799-3146-0. S2CID 8593041.
  40. ^ Buevich, Maxim; Zhang, Xiao; Schnitzer, Dan; Escalada, Tristan; Jacquiau-Chamski, Arthur; Thacker, Jon; Rowe, Anthony (1 January 2015). "Short Paper: Microgrid Losses". Proceedings of the 2nd ACM International Conference on Embedded Systems for Energy-Efficient Built Environments. BuildSys '15. pp. 95–98. doi:10.1145/2821650.2821676. ISBN 9781450339810. S2CID 2742485.
  41. ^ Kirubi, et al. "Community-Based Electric Micro-Grids Can Contribute to Rural Development: Evidence from Kenya." World Development, vol. 37, no. 7, 2009, pp. 1208–1221.
  42. ^ "Microgrid at Stone Edge Farm Wins California Environmental Honor". Microgrid Knowledge. 18 January 2018. Retrieved 28 June 2018.
  43. ^ "Stone Edge Farm — A Sandbox For Microgrid Development | CleanTechnica". cleantechnica.com. 24 November 2017. Retrieved 28 June 2018.
  44. ^ (PDF). Leipzig: Market Surveillance (HÜSt) group of the European Energy Exchange. 30 October 2008: 4. Archived from the original (PDF) on 10 July 2011. Retrieved 6 December 2008. {{cite journal}}: Cite journal requires |journal= (help)
  45. ^ Haubrich, Hans-Jürgen; Denzel, Dieter (23 October 2008). (PDF). Operation of Interconnected Power Systems (PDF). Aachen: Institute for Electrical Equipment and Power Plants (IAEW) at RWTH Aachen University. p. 3. Archived from the original (PDF) on 19 July 2011. Retrieved 6 December 2008. (See "Operation of Power Systems" link for title page and table of contents.)
  46. ^ "Serbia, Kosovo power grid row delays European clocks". Reuters. 7 March 2018.
  47. ^ Cooper, Christopher; Sovacool, Benjamin K. (February 2013). "Miracle or mirage? The promise and peril of desert energy part 1". Renewable energy. 50: 628–636. doi:10.1016/j.renene.2012.07.027.
  48. ^ . Global Energy Interconnection (GEIDCO). Archived from the original on 1 February 2020. Retrieved 26 January 2020.
  49. ^ Mezősi, András; Pató, Zsuzsanna; Szabó, László (2016). "Assessment of the EU 10% interconnection target in the context of CO2 mitigation†". Climate Policy. 16 (5): 658–672. doi:10.1080/14693062.2016.1160864.
  50. ^ . Reuters. 13 August 2008. Archived from the original on 19 February 2009. Retrieved 22 November 2008. Demand response can be achieved at the wholesale level with major energy users such as industrial plants curtailing power use and receiving payment for participating.
  51. ^ Willis, H. L., Welch, G. V., and Schrieber, R. R. (2001). Aging Power Delivery Infrastructures. New York: Marcel Dekker, Inc. 551 pgs.
  52. ^ Randolph, Kevin (21 July 2017). "In order to integrate the grid, disparate industries need to work together". Daily Energy Insider. Retrieved 3 August 2017.
  53. ^ Smart Grid - The New and Improved Power Grid: A Survey; IEEE Communications Surveys and Tutorials 2011; X. Fang, S. Misra, G. Xue, and D. Yang; doi:10.1109/SURV.2011.101911.00087.
  54. ^ Alexandra Von Meier (2013). Electrical Engineer 137A: Electric Power Systems. Lecture 2:Introduction to Electric Power Systems, Slide 33.
  55. ^ Nunez, Christina (14 December 2012). "Who’s Watching? Privacy Concerns Persist as Smart Meters Roll Out 2018-03-16 at the Wayback Machine". National Geographic. nationalgeographic.com. Retrieved 16 March 2018.
  56. ^ . Archived from the original on 19 December 2015. Retrieved 23 December 2007.
  57. ^ DOE Provides up to $51.8 Million to Modernize the U.S. Electric Grid System 20 September 2008 at the Wayback Machine, 27 June 2007, U.S. Department of Energy (DOE)
  58. ^ Kantamneni, Abhilash; Winkler, Richelle; Gauchia, Lucia; Pearce, Joshua M. (2016). "free open access Emerging economic viability of grid defection in a northern climate using solar hybrid systems". Energy Policy. 95: 378–389. doi:10.1016/j.enpol.2016.05.013.
  59. ^ Khalilpour, R.; Vassallo, A. (2015). "Leaving the grid: An ambition or a real choice?". Energy Policy. 82: 207–221. doi:10.1016/j.enpol.2015.03.005.
  60. ^ Kumagai, J (2014). "The rise of the personal power plant". IEEE Spectrum. 51 (6): 54–59. doi:10.1109/mspec.2014.6821622. S2CID 36554641.
  61. ^ The Economics of Grid Defection - Rocky Mountain Institute . Archived from the original on 12 August 2016. Retrieved 13 August 2016.
  62. ^ Andy Balaskovitz Net metering changes could drive people off grid, Michigan researchers say 15 June 2016 at the Wayback Machine - MidWest Energy News
  63. ^ "Grid defection and why we don't want it". 16 June 2015.

External links edit

electrical, grid, other, uses, grid, disambiguation, power, grid, redirects, here, board, game, power, grid, electrical, grid, interconnected, network, electricity, delivery, from, producers, consumers, vary, size, cover, whole, countries, continents, consists. For other uses see Grid disambiguation Power grid redirects here For the board game see Power Grid An electrical grid is an interconnected network for electricity delivery from producers to consumers Electrical grids vary in size and can cover whole countries or continents It consists of 1 power stations often located near source of energy and away from heavily populated areas electrical substations to step voltage up or down electric power transmission to carry power long distances electric power distribution to individual customers where voltage is stepped down again to the required service voltage s General layout of electricity networks Voltages and depictions of electrical lines are typical for Germany and other European systems Grids are nearly always synchronous meaning all distribution areas operate with three phase alternating current AC frequencies synchronized so that voltage swings occur at almost the same time This allows transmission of AC power throughout the area connecting a large number of electricity generators and consumers and potentially enabling more efficient electricity markets and redundant generation The combined transmission and distribution network is part of electricity delivery known as the power grid in North America or just the grid In the United Kingdom India Tanzania Myanmar Malaysia and New Zealand the network is known as the National Grid Although electrical grids are widespread as of 2016 update 1 4 billion people worldwide were not connected to an electricity grid 2 As electrification increases the number of people with access to grid electricity is growing About 840 million people mostly in Africa which is ca 11 of the World s population had no access to grid electricity in 2017 down from 1 2 billion in 2010 3 Electrical grids can be prone to malicious intrusion or attack thus there is a need for electric grid security Also as electric grids modernize and introduce computer technology cyber threats start to become a security risk 4 Particular concerns relate to the more complex computer systems needed to manage grids 5 Contents 1 History 2 Components 2 1 Generation 2 2 Transmission 2 3 Substations 2 4 Electric power distribution 2 5 Storage 3 Functionalities 3 1 Demand 3 2 Voltage 3 3 Frequency 3 4 Capacity and firm capacity 3 5 Production 3 6 Handling failure 3 6 1 Brownout 3 6 2 Blackout 3 6 3 Load shedding 3 6 4 Black start 4 Scale 4 1 Microgrid 4 2 Wide area synchronous grid 4 3 Super grid 5 Trends 5 1 Demand response 5 2 Aging infrastructure 5 3 Distributed generation 5 4 Smart grid 5 5 Grid defection 6 See also 7 References 8 External linksHistory editEarly electric energy was produced near the device or service requiring that energy In the 1880s electricity competed with steam hydraulics and especially coal gas Coal gas was first produced on customer s premises but later evolved into gasification plants that enjoyed economies of scale In the industrialized world cities had networks of piped gas used for lighting But gas lamps produced poor light wasted heat made rooms hot and smokey and gave off hydrogen and carbon monoxide They also posed a fire hazard In the 1880s electric lighting soon became advantageous compared to gas lighting Electric utility companies established central stations to take advantage of economies of scale and moved to centralized power generation distribution and system management 6 After the war of the currents was settled in favor of AC power with long distance power transmission it became possible to interconnect stations to balance the loads and improve load factors Historically transmission and distribution lines were owned by the same company but starting in the 1990s many countries have liberalized the regulation of the electricity market in ways that have led to the separation of the electricity transmission business from the distribution business 7 In the United Kingdom Charles Merz of the Merz amp McLellan consulting partnership built the Neptune Bank Power Station near Newcastle upon Tyne in 1901 8 and by 1912 had developed into the largest integrated power system in Europe 9 Merz was appointed head of a parliamentary committee and his findings led to the Williamson Report of 1918 which in turn created the Electricity Supply Act 1919 The bill was the first step towards an integrated electricity system The Electricity Supply Act 1926 led to the setting up of the National Grid 10 The Central Electricity Board standardized the nation s electricity supply and established the first synchronized AC grid running at 132 kilovolts and 50 hertz This started operating as a national system the National Grid in 1938 In France electrification began in the 1900s with 700 communes in 1919 and 36 528 in 1938 At the same time these close networks began to interconnect Paris in 1907 at 12 kV the Pyrenees in 1923 at 150 kV and finally almost all of the country interconnected by 1938 at 220 kV In 1946 the grid was the world s most dense That year the state nationalised the industry by uniting the private companies as Electricite de France The frequency was standardised at 50 Hz and the 225 kV network replaced 110 kV and 120 kV Since 1956 service voltage has been standardised at 220 380 V replacing the previous 127 220 V During the 1970s the 400 kV network the new European standard was implemented In the United States in the 1920s utilities formed joint operations to share peak load coverage and backup power In 1934 with the passage of the Public Utility Holding Company Act USA electric utilities were recognized as public goods of importance and were given outlined restrictions and regulatory oversight of their operations The Energy Policy Act of 1992 required transmission line owners to allow electric generation companies open access to their network 6 11 and led to a restructuring of how the electric industry operated in an effort to create competition in power generation No longer were electric utilities built as vertical monopolies where generation transmission and distribution were handled by a single company Now the three stages could be split among various companies in an effort to provide fair access to high voltage transmission 12 21 The Energy Policy Act of 2005 allowed incentives and loan guarantees for alternative energy production and advance innovative technologies that avoided greenhouse emissions Soviet Union was the first country to implement a large scale electrification program in 10 years between 1930 and 1940 the country s electricity output increased from 2 6 billion kWh to 13 5 billion kWh see GOELRO The USSR continued to pursue electrification and grid intergration with its ally countries World s largest electric grid Mir see ru Mir energosistema encompassed 9 countries from East Germany to Mongolia between ca 1960 and 1990 It achieved power of 400 000 MW In China electrification began in the 1950s 13 In August 1961 the electrification of the Baoji Fengzhou section of the Baocheng Railway was completed and delivered for operation becoming China s first electrified railway 14 From 1958 to 1998 China s electrified railway reached 6 200 miles 10 000 kilometres 15 As of the end of 2017 this number has reached 54 000 miles 87 000 kilometres 16 In the current railway electrification system of China State Grid Corporation of China Archived 2021 12 21 at the Wayback Machine is an important power supplier In 2019 it completed the power supply project of China s important electrified railways in its operating areas such as Jingtong Railway Haoji Railway Zhengzhou Wanzhou high speed railway et cetera providing power supply guarantee for 110 traction stations and its cumulative power line construction length reached 6 586 kilometres 17 Components editGeneration edit Main article Electricity generation nbsp Turbo generator nbsp Diagram of an electric power system generation system in redElectricity generation is the process of generating electric power from sources of primary energy typically at power stations Usually this is done with electromechanical generators driven by heat engines or the kinetic energy of water or wind Other energy sources include solar photovoltaics and geothermal power The sum of the power outputs of generators on the grid is the production of the grid typically measured in gigawatts GW Transmission edit Main article Electric power transmission nbsp 500 kV Three phase electric power Transmission Lines at Grand Coulee Dam four circuits are shown two additional circuits are obscured by trees on the right the entire 7079 MW generation capacity of the dam is accommodated by these six circuits Electric power transmission is the bulk movement of electrical energy from a generating site via a web of interconnected lines to an electrical substation from which is connected to the distribution system This networked system of connections is distinct from the local wiring between high voltage substations and customers Because the power is often generated far from where it is consumed the transmission system can cover great distances For a given amount of power transmission efficiency is greater at higher voltages and lower currents Therefore voltages are stepped up at the generating station and stepped down at local substations for distribution to customers Most transmission is three phase Three phase compared to single phase can deliver much more power for a given amount of wire since the neutral and ground wires are shared 18 Further three phase generators and motors are more efficient than their single phase counterparts However for conventional conductors one of the main losses are resistive losses which are a square law on current and depend on distance High voltage AC transmission lines can lose 1 4 per hundred miles 19 However high voltage direct current can have half the losses of AC Over very long distances these efficiencies can offset the additional cost of the required AC DC converter stations at each end nbsp Network diagram of a high voltage transmission system showing the interconnection between the different voltage levels This diagram depicts the electrical structure 20 of the network rather than its physical geography Transmission networks are complex with redundant pathways The physical layout is often forced by what land is available and its geology Most transmission grids offer the reliability that more complex mesh networks provide Redundancy allows line failures to occur and power is simply rerouted while repairs are done Substations edit Main article Electrical substation Substations may perform many different functions but usually transform voltage from low to high step up and from high to low step down Between the generator and the final consumer the voltage may be transformed several times 21 The three main types of substations by function are 22 Step up substation these use transformers to raise the voltage coming from the generators and power plants so that power can be transmitted long distances more efficiently with smaller currents Step down substation these transformers lower the voltage coming from the transmission lines which can be used in industry or sent to a distribution substation Distribution substation these transform the voltage lower again for the distribution to end users Aside from transformers other major components or functions of substations include Circuit breakers used to automatically break a circuit and isolate a fault in the system 23 Switches to control the flow of electricity and isolate equipment 24 The substation busbar typically a set of three conductors one for each phase of current The substation is organized around the buses and they are connected to incoming lines transformers protection equipment switches and the outgoing lines 23 Lightning arresters Capacitors for power factor correction Synchronous condensers for power factor correction and grid stabilityElectric power distribution edit Main article Electric power distribution Distribution is the final stage in the delivery of power it carries electricity from the transmission system to individual consumers Substations connect to the transmission system and lower the transmission voltage to medium voltage ranging between 2 kV and 35 kV Primary distribution lines carry this medium voltage power to distribution transformers located near the customer s premises Distribution transformers again lower the voltage to the utilization voltage Customers demanding a much larger amount of power may be connected directly to the primary distribution level or the subtransmission level 25 Distribution networks are divided into two types radial or network 26 In cities and towns of North America the grid tends to follow the classic radially fed design A substation receives its power from the transmission network the power is stepped down with a transformer and sent to a bus from which feeders fan out in all directions across the countryside These feeders carry three phase power and tend to follow the major streets near the substation As the distance from the substation grows the fanout continues as smaller laterals spread out to cover areas missed by the feeders This tree like structure grows outward from the substation but for reliability reasons usually contains at least one unused backup connection to a nearby substation This connection can be enabled in case of an emergency so that a portion of a substation s service territory can be alternatively fed by another substation Storage edit Main article Grid energy storage nbsp Simplified electrical grid with energy storage nbsp Simplified grid energy flow with and without idealized energy storage for the course of one dayGrid energy storage also called large scale energy storage is a collection of methods used for energy storage on a large scale within an electrical power grid Electrical energy is stored during times when electricity is plentiful and inexpensive especially from intermittent power sources such as renewable electricity from wind power tidal power and solar power or when demand is low and later returned to the grid when demand is high and electricity prices tend to be higher As of 2020 update the largest form of grid energy storage is dammed hydroelectricity with both conventional hydroelectric generation as well as pumped storage hydroelectricity Developments in battery storage have enabled commercially viable projects to store energy during peak production and release during peak demand and for use when production unexpectedly falls giving time for slower responding resources to be brought online Two alternatives to grid storage are the use of peaking power plants to fill in supply gaps and demand response to shift load to other times Functionalities editDemand edit The demand or load on an electrical grid is the total electrical power being removed by the users of the grid The graph of the demand over time is called the demand curve Baseload is the minimum load on the grid over any given period peak demand is the maximum load Historically baseload was commonly met by equipment that was relatively cheap to run that ran continuously for weeks or months at a time but globally this is becoming less common The extra peak demand requirements are sometimes produced by expensive peaking plants that are generators optimised to come on line quickly but these too are becoming less common However if the demand of electricity exceed the capacity of a local power grid it will cause safety issue like burning out 27 Voltage edit Grids are designed to supply electricity to their customers at largely constant voltages This has to be achieved with varying demand variable reactive loads and even nonlinear loads with electricity provided by generators and distribution and transmission equipment that are not perfectly reliable 28 Often grids use tap changers on transformers near to the consumers to adjust the voltage and keep it within specification Frequency edit Main article Utility frequency In a synchronous grid all the generators must run at the same frequency and must stay very nearly in phase with each other and the grid Generation and consumption must be balanced across the entire grid because energy is consumed as it is produced For rotating generators a local governor regulates the driving torque maintaining almost constant rotation speed as loading changes Energy is stored in the immediate short term by the rotational kinetic energy of the generators Although the speed is kept largely constant small deviations from the nominal system frequency are very important in regulating individual generators and are used as a way of assessing the equilibrium of the grid as a whole When the grid is lightly loaded the grid frequency runs above the nominal frequency and this is taken as an indication by Automatic Generation Control systems across the network that generators should reduce their output Conversely when the grid is heavily loaded the frequency naturally slows and governors adjust their generators so that more power is output droop speed control When generators have identical droop speed control settings it ensures that multiple parallel generators with the same settings share load in proportion to their rating In addition there s often central control which can change the parameters of the AGC systems over timescales of a minute or longer to further adjust the regional network flows and the operating frequency of the grid For timekeeping purposes the nominal frequency will be allowed to vary in the short term but is adjusted to prevent line operated clocks from gaining or losing significant time over the course of a whole 24 hour period An entire synchronous grid runs at the same frequency neighbouring grids would not be synchronised even if they run at the same nominal frequency High voltage direct current lines or variable frequency transformers can be used to connect two alternating current interconnection networks which are not synchronized with each other This provides the benefit of interconnection without the need to synchronize an even wider area For example compare the wide area synchronous grid map of Europe with the map of HVDC lines Capacity and firm capacity edit The sum of the maximum power outputs nameplate capacity of the generators attached to an electrical grid might be considered to be the capacity of the grid However in practice they are never run flat out simultaneously Typically some generators are kept running at lower output powers spinning reserve to deal with failures as well as variation in demand In addition generators can be off line for maintenance or other reasons such as availability of energy inputs fuel water wind sun etc or pollution constraints Firm capacity is the maximum power output on a grid that is immediately available over a given time period and is a far more useful figure Production edit Most grid codes specify that the load is shared between the generators in merit order according to their marginal cost i e cheapest first and sometimes their environmental impact Thus cheap electricity providers tend to be run flat out almost all the time and the more expensive producers are only run when necessary Handling failure edit Failures are usually associated with generators or power transmission lines tripping circuit breakers due to faults leading to a loss of generation capacity for customers or excess demand This will often cause the frequency to reduce and the remaining generators will react and together attempt to stabilize above the minimum If that is not possible then a number of scenarios can occur A large failure in one part of the grid unless quickly compensated for can cause current to re route itself to flow from the remaining generators to consumers over transmission lines of insufficient capacity causing further failures One downside to a widely connected grid is thus the possibility of cascading failure and widespread power outage A central authority is usually designated to facilitate communication and develop protocols to maintain a stable grid For example the North American Electric Reliability Corporation gained binding powers in the United States in 2006 and has advisory powers in the applicable parts of Canada and Mexico The U S government has also designated National Interest Electric Transmission Corridors where it believes transmission bottlenecks have developed Brownout edit Main article Brownout electricity nbsp A brownout near Tokyo Tower in Tokyo JapanA brownout is an intentional or unintentional drop in voltage in an electrical power supply system Intentional brownouts are used for load reduction in an emergency 29 The reduction lasts for minutes or hours as opposed to short term voltage sag or dip The term brownout comes from the dimming experienced by incandescent lighting when the voltage sags A voltage reduction may be an effect of disruption of an electrical grid or may occasionally be imposed in an effort to reduce load and prevent a power outage known as a blackout 30 Blackout edit Main article Power outage A power outage also called a power cut a power out a power blackout power failure or a blackout is a loss of the electric power to a particular area Power failures can be caused by faults at power stations damage to electric transmission lines substations or other parts of the distribution system a short circuit cascading failure fuse or circuit breaker operation and human error Power failures are particularly critical at sites where the environment and public safety are at risk Institutions such as hospitals sewage treatment plants mines shelters and the like will usually have backup power sources such as standby generators which will automatically start up when electrical power is lost Other critical systems such as telecommunication are also required to have emergency power The battery room of a telephone exchange usually has arrays of lead acid batteries for backup and also a socket for connecting a generator during extended periods of outage Load shedding edit Main article Demand response Electrical generation and transmission systems may not always meet peak demand requirements the greatest amount of electricity required by all utility customers within a given region In these situations overall demand must be lowered either by turning off service to some devices or cutting back the supply voltage brownouts in order to prevent uncontrolled service disruptions such as power outages widespread blackouts or equipment damage Utilities may impose load shedding on service areas via targeted blackouts rolling blackouts or by agreements with specific high use industrial consumers to turn off equipment at times of system wide peak demand Black start edit Main article Black start nbsp Toronto during the Northeast blackout of 2003 which required black starting of generating stations A black start is the process of restoring an electric power station or a part of an electric grid to operation without relying on the external electric power transmission network to recover from a total or partial shutdown 31 Normally the electric power used within the plant is provided from the station s own generators If all of the plant s main generators are shut down station service power is provided by drawing power from the grid through the plant s transmission line However during a wide area outage off site power from the grid is not available In the absence of grid power a so called black start needs to be performed to bootstrap the power grid into operation To provide a black start some power stations have small diesel generators normally called the black start diesel generator BSDG which can be used to start larger generators of several megawatts capacity which in turn can be used to start the main power station generators Generating plants using steam turbines require station service power of up to 10 of their capacity for boiler feedwater pumps boiler forced draft combustion air blowers and for fuel preparation It is uneconomical to provide such a large standby capacity at each station so black start power must be provided over designated tie lines from another station Often hydroelectric power plants are designated as the black start sources to restore network interconnections A hydroelectric station needs very little initial power to start just enough to open the intake gates and provide excitation current to the generator field coils and can put a large block of power on line very quickly to allow start up of fossil fuel or nuclear stations Certain types of combustion turbine can be configured for black start providing another option in places without suitable hydroelectric plants 32 In 2017 a utility in Southern California has successfully demonstrated the use of a battery energy storage system to provide a black start firing up a combined cycle gas turbine from an idle state 33 Scale editMicrogrid edit Main article Microgrid A microgrid is a local grid that is usually part of the regional wide area synchronous grid but which can disconnect and operate autonomously 34 It might do this in times when the main grid is affected by outages This is known as islanding and it might run indefinitely on its own resources Compared to larger grids microgrids typically use a lower voltage distribution network and distributed generators 35 Microgrids may not only be more resilient but may be cheaper to implement in isolated areas A design goal is that a local area produces all of the energy it uses 34 Example implementations include Hajjah and Lahj Yemen community owned solar microgrids 36 Ile d Yeu pilot program sixty four solar panels with a peak capacity of 23 7 kW on five houses and a battery with a storage capacity of 15 kWh 37 38 Les Anglais Haiti 39 includes energy theft detection 40 Mpeketoni Kenya a community based diesel powered micro grid system 41 Stone Edge Farm Winery micro turbine fuel cell multiple battery hydrogen electrolyzer and PV enabled winery in Sonoma California 42 43 Wide area synchronous grid edit Main article Wide area synchronous grid A wide area synchronous grid also known as an interconnection in North America directly connects many generators delivering AC power with the same relative frequency to many consumers For example there are four major interconnections in North America the Western Interconnection the Eastern Interconnection the Quebec Interconnection and the Texas Interconnection In Europe one large grid connects most of continental Europe A wide area synchronous grid also called an interconnection in North America is an electrical grid at a regional scale or greater that operates at a synchronized frequency and is electrically tied together during normal system conditions These are also known as synchronous zones the largest of which is the synchronous grid of Continental Europe ENTSO E with 667 gigawatts GW of generation and the widest region served being that of the IPS UPS system serving countries of the former Soviet Union Synchronous grids with ample capacity facilitate electricity market trading across wide areas In the ENTSO E in 2008 over 350 000 megawatt hours were sold per day on the European Energy Exchange EEX 44 Each of the interconnects in North America are run at a nominal 60 Hz while those of Europe run at 50 Hz Neighbouring interconnections with the same frequency and standards can be synchronized and directly connected to form a larger interconnection or they may share power without synchronization via high voltage direct current power transmission lines DC ties or with variable frequency transformers VFTs which permit a controlled flow of energy while also functionally isolating the independent AC frequencies of each side The benefits of synchronous zones include pooling of generation resulting in lower generation costs pooling of load resulting in significant equalizing effects common provisioning of reserves resulting in cheaper primary and secondary reserve power costs opening of the market resulting in possibility of long term contracts and short term power exchanges and mutual assistance in the event of disturbances 45 One disadvantage of a wide area synchronous grid is that problems in one part can have repercussions across the whole grid For example in 2018 Kosovo used more power than it generated due to a dispute with Serbia leading to the phase across the whole synchronous grid of Continental Europe lagging behind what it should have been The frequency dropped to 49 996 Hz This caused certain kinds of clocks to become six minutes slow 46 nbsp The synchronous grids of Europe nbsp The two major and three minor interconnections of North America nbsp Major WASGs around the worldSuper grid edit Main article Super grid nbsp One conceptual plan of a super grid linking renewable sources across North Africa the Middle East and Europe DESERTEC 47 A super grid or supergrid is a wide area transmission network that is intended to make possible the trade of high volumes of electricity across great distances It is sometimes also referred to as a mega grid Super grids can support a global energy transition by smoothing local fluctuations of wind energy and solar energy In this context they are considered as a key technology to mitigate global warming Super grids typically use High voltage direct current HVDC to transmit electricity long distances The latest generation of HVDC power lines can transmit energy with losses of only 1 6 per 1000 km 48 Electric utilities between regions are many times interconnected for improved economy and reliability Electrical interconnectors allow for economies of scale allowing energy to be purchased from large efficient sources Utilities can draw power from generator reserves from a different region to ensure continuing reliable power and diversify their loads Interconnection also allows regions to have access to cheap bulk energy by receiving power from different sources For example one region may be producing cheap hydro power during high water seasons but in low water seasons another area may be producing cheaper power through wind allowing both regions to access cheaper energy sources from one another during different times of the year Neighboring utilities also help others to maintain the overall system frequency and also help manage tie transfers between utility regions 12 Electricity Interconnection Level EIL of a grid is the ratio of the total interconnector power to the grid divided by the installed production capacity of the grid Within the EU it has set a target of national grids reaching 10 by 2020 and 15 by 2030 49 Trends editDemand response edit Demand response is a grid management technique where retail or wholesale customers are requested or incentivised either electronically or manually to reduce their load Currently transmission grid operators use demand response to request load reduction from major energy users such as industrial plants 50 Technologies such as smart metering can encourage customers to use power when electricity is plentiful by allowing for variable pricing Aging infrastructure edit Despite the novel institutional arrangements and network designs of the electrical grid its power delivery infrastructures suffer aging across the developed world Contributing factors to the current state of the electric grid and its consequences include Aging equipment older equipment has higher failure rates leading to customer interruption rates affecting the economy and society also older assets and facilities lead to higher inspection maintenance costs and further repair and restoration costs Obsolete system layout older areas require serious additional substation sites and rights of way that cannot be obtained in the current area and are forced to use existing insufficient facilities Outdated engineering traditional tools for power delivery planning and engineering are ineffective in addressing current problems of aged equipment obsolete system layouts and modern deregulated loading levels Old cultural value planning engineering operating of system using concepts and procedures that worked in vertically integrated industry exacerbate the problem under a deregulated industry 51 Distributed generation edit With everything interconnected and open competition occurring in a free market economy it starts to make sense to allow and even encourage distributed generation DG Smaller generators usually not owned by the utility can be brought on line to help supply the need for power The smaller generation facility might be a home owner with excess power from their solar panel or wind turbine It might be a small office with a diesel generator These resources can be brought on line either at the utility s behest or by owner of the generation in an effort to sell electricity Many small generators are allowed to sell electricity back to the grid for the same price they would pay to buy it As the 21st century progresses the electric utility industry seeks to take advantage of novel approaches to meet growing energy demand Utilities are under pressure to evolve their classic topologies to accommodate distributed generation As generation becomes more common from rooftop solar and wind generators the differences between distribution and transmission grids will continue to blur In July 2017 the CEO of Mercedes Benz said that the energy industry needs to work better with companies from other industries to form a total ecosystem to integrate central and distributed energy resources DER to give customers what they want The electrical grid was originally constructed so that electricity would flow from power providers to consumers However with the introduction of DER power needs to flow both ways on the electric grid because customers may have power sources such as solar panels 52 Smart grid edit Main article Smart grid The smart grid would be an enhancement of the 20th century electrical grid using two way communications and distributed so called intelligent devices Two way flows of electricity and information could improve the delivery network Research is mainly focused on three systems of a smart grid the infrastructure system the management system and the protection system 53 The infrastructure system is the energy information and communication infrastructure underlying of the smart grid that supports Advanced electricity generation delivery and consumption Advanced information metering monitoring and management Advanced communication technologiesA smart grid would allow the power industry to observe and control parts of the system at higher resolution in time and space 54 One of the purposes of the smart grid is real time information exchange to make operation as efficient as possible It would allow management of the grid on all time scales from high frequency switching devices on a microsecond scale to wind and solar output variations on a minute scale to the future effects of the carbon emissions generated by power production on a decade scale The management system is the subsystem in smart grid that provides advanced management and control services Most of the existing works aim to improve energy efficiency demand profile utility cost and emission based on the infrastructure by using optimization machine learning and game theory Within the advanced infrastructure framework of smart grid more and more new management services and applications are expected to emerge and eventually revolutionize consumers daily lives The protection system of a smart grid provides grid reliability analysis failure protection and security and privacy protection services While the additional communication infrastructure of a smart grid provides additional protective and security mechanisms it also presents a risk of external attack and internal failures In a report on cyber security of smart grid technology first produced in 2010 and later updated in 2014 the US National Institute of Standards and Technology pointed out that the ability to collect more data about energy use from customer smart meters also raises major privacy concerns since the information stored at the meter which is potentially vulnerable to data breaches can be mined for personal details about customers 55 In the U S the Energy Policy Act of 2005 and Title XIII of the Energy Independence and Security Act of 2007 are providing funding to encourage smart grid development The objective is to enable utilities to better predict their needs and in some cases involve consumers in a time of use tariff Funds have also been allocated to develop more robust energy control technologies 56 57 Grid defection edit As there is some resistance in the electric utility sector to the concepts of distributed generation with various renewable energy sources and microscale cogen units several authors have warned that mass scale grid defection definition needed is possible because consumers can produce electricity using off grid systems primarily made up of solar photovoltaic technology 58 59 60 The Rocky Mountain Institute has proposed that there may be widescale grid defection 61 This is backed up by studies in the Midwest 62 However the paper points out that grid defection may be less likely in countries like Germany which have greater power demands in winter 63 See also editGrid code a specification for grid connected equipment North American power transmission grid North American Electric Reliability Corporation NERC Rural Electrification ActReferences edit Kaplan S M 2009 Smart Grid Electrical Power Transmission Background and Policy Issues The Capital Net Government Series Pp 1 42 Overland Indra 1 April 2016 Energy The missing link in globalization Energy Research amp Social Science 14 122 130 doi 10 1016 j erss 2016 01 009 Archived from the original on 5 February 2018 if all countries in the world were to make do with their own resources there would be even more energy poverty in the world than there is now Currently 1 4 billion people are not connected to an electricity grid Odarno Lily 14 August 2019 Closing Sub Saharan Africa s Electricity Access Gap Why Cities Must Be Part of the Solution a href Template Cite journal html title Template Cite journal cite journal a Cite journal requires journal help Douris Constance As Cyber Threats To The Electric Grid Rise Utilities And Regulators Seek Solutions Forbes Retrieved 27 September 2018 Overland Indra 1 March 2019 The geopolitics of renewable energy Debunking four emerging myths Energy Research amp Social Science 49 36 40 doi 10 1016 j erss 2018 10 018 ISSN 2214 6296 a b Borberly A and Kreider J F 2001 Distributed Generation The Power Paradigm for the New Millennium CRC Press Boca Raton FL 400 pgs A Primer on Electric Utilities Deregulation and Restructuring of U S Electricity Markets PDF United States Department of Energy Federal Energy Management Program FEMP May 2002 Retrieved 30 October 2018 a href Template Cite journal html title Template Cite journal cite journal a Cite journal requires journal help Mr Alan Shaw 29 September 2005 Kelvin to Weir and on to GB SYS 2005 PDF Royal Society of Edinburgh Archived PDF from the original on 4 March 2009 Survey of Belford 1995 North Northumberland Online Archived from the original on 2016 04 12 Retrieved 2013 10 06 Lighting by electricity The National Trust Archived from the original on 29 June 2011 Mazer A 2007 Electric Power Planning for Regulated and Deregulated Markets John Wiley and Sons Inc Hoboken NJ 313pgs a b 2001 Glover J D Sarma M S Overbye T J 2010 Power System and Analysis 5th Edition Cengage Learning Pg 10 People s Republic of China Year Book Xinhua Publishing House 1989 p 190 China Report Economic affairs Foreign Broadcast Information Service Joint Publications Research Service 1984 p 54 Hong Kong Express Rail Link officially opens Xinhuanet com 3 October 2018 Archived from the original on 18 October 2018 Avishek G Dastidar 13 September 2018 After initial questions government clears 100 Railways electrification The Indian Express Beijing Zhangjiakou intercity railway opens National Development and Reform Commission 6 January 2020 Archived from the original on 3 March 2021 Retrieved 24 June 2020 Sajip Jahnavi Why Do We Use Three Phase Power www ny engineers com Retrieved 22 April 2021 Archived copy PDF www aep com Archived from the original PDF on 4 June 2011 Retrieved 11 January 2022 a href Template Cite web html title Template Cite web cite web a CS1 maint archived copy as title link Cuffe Paul Keane Andrew 2017 Visualizing the Electrical Structure of Power Systems IEEE Systems Journal 11 3 1810 1821 Bibcode 2017ISysJ 11 1810C doi 10 1109 JSYST 2015 2427994 hdl 10197 7108 ISSN 1932 8184 S2CID 10085130 The basic things about substations you MUST know in the middle of the night EEP Electrical Engineering Portal 9 January 2019 Retrieved 23 April 2021 Electrical substation energyeducation ca University of Calgary Retrieved 23 April 2021 a b Hayes Brian 2005 Infrastructure a field guide to the industrial landscape 1st ed New York W W Norton ISBN 0 393 05997 9 Hillhouse Grady How Do Substations Work Practical Engineering Retrieved 23 April 2021 How Power Grids Work HowStuffWorks April 2000 Retrieved 18 March 2016 Sallam Abdelhay A amp Malik Om P May 2011 Electric Distribution Systems IEEE Computer Society Press p 21 ISBN 9780470276822 Wang Yingcheng Gladwin Daniel January 2021 Power Management Analysis of a Photovoltaic and Battery Energy Storage Based Smart Electrical Car Park Providing Ancillary Grid Services Energies 14 24 8433 doi 10 3390 en14248433 ISSN 1996 1073 Archived copy PDF Archived PDF from the original on 8 May 2018 Retrieved 28 August 2017 a href Template Cite web html title Template Cite web cite web a CS1 maint archived copy as title link Steven Warren Blume Electric power system basics for the nonelectrical professional John Wiley amp Sons 2007 ISBN 0470129875 p 199 Alan Wyatt Electric Power Challenges and Choices The Book Press Limited Toronto 1986 ISBN 0 920650 00 7 page 63 Knight U G Power Systems in Emergencies From Contingency Planning to Crisis Management John Wiley amp Sons 2001 ISBN 978 0 471 49016 6 section 7 5 The Black Start Situation Philip P Walsh Paul Fletcher Gas turbine performance John Wiley and Sons 2004 ISBN 0 632 06434 X page 486 California battery s black start capability hailed as major accomplishment in the energy industry 17 May 2017 a b How Microgrids Work Energy gov Retrieved 19 April 2021 Khaitan Siddhartha Kumar Venkatraman Ramakrishnan A Survey of Techniques for Designing and Managing Microgrids Retrieved 19 April 2021 UNDP Yemen wins acclaimed international Ashden Awards for Humanitarian Energy Archived from the original on 2021 05 04 Retrieved 2021 04 19 Spaes Joel 3 July 2020 Harmon Yeu premiere communaute energetique a l Ile d Yeu signee Engie www pv magazine fr Retrieved 27 January 2021 Wakim Nabil 16 December 2020 A L Ile d Yeu soleil pour tous ou presque www lemonde fr Retrieved 27 January 2021 Buevich Maxim Schnitzer Dan Escalada Tristan Jacquiau Chamski Arthur Rowe Anthony 2014 Fine grained remote monitoring control and pre paid electrical service in rural microgrids IPSN 14 Proceedings of the 13th International Symposium on Information Processing in Sensor Networks pp 1 11 doi 10 1109 IPSN 2014 6846736 ISBN 978 1 4799 3146 0 S2CID 8593041 Buevich Maxim Zhang Xiao Schnitzer Dan Escalada Tristan Jacquiau Chamski Arthur Thacker Jon Rowe Anthony 1 January 2015 Short Paper Microgrid Losses Proceedings of the 2nd ACM International Conference on Embedded Systems for Energy Efficient Built Environments BuildSys 15 pp 95 98 doi 10 1145 2821650 2821676 ISBN 9781450339810 S2CID 2742485 Kirubi et al Community Based Electric Micro Grids Can Contribute to Rural Development Evidence from Kenya World Development vol 37 no 7 2009 pp 1208 1221 Microgrid at Stone Edge Farm Wins California Environmental Honor Microgrid Knowledge 18 January 2018 Retrieved 28 June 2018 Stone Edge Farm A Sandbox For Microgrid Development CleanTechnica cleantechnica com 24 November 2017 Retrieved 28 June 2018 EEX Market Monitor Q3 2008 PDF Leipzig Market Surveillance HUSt group of the European Energy Exchange 30 October 2008 4 Archived from the original PDF on 10 July 2011 Retrieved 6 December 2008 a href Template Cite journal html title Template Cite journal cite journal a Cite journal requires journal help Haubrich Hans Jurgen Denzel Dieter 23 October 2008 Characteristics of interconnected operation PDF Operation of Interconnected Power Systems PDF Aachen Institute for Electrical Equipment and Power Plants IAEW at RWTH Aachen University p 3 Archived from the original PDF on 19 July 2011 Retrieved 6 December 2008 See Operation of Power Systems link for title page and table of contents Serbia Kosovo power grid row delays European clocks Reuters 7 March 2018 Cooper Christopher Sovacool Benjamin K February 2013 Miracle or mirage The promise and peril of desert energy part 1 Renewable energy 50 628 636 doi 10 1016 j renene 2012 07 027 UHV Grid Global Energy Interconnection GEIDCO Archived from the original on 1 February 2020 Retrieved 26 January 2020 Mezosi Andras Pato Zsuzsanna Szabo Laszlo 2016 Assessment of the EU 10 interconnection target in the context of CO2 mitigation Climate Policy 16 5 658 672 doi 10 1080 14693062 2016 1160864 Industry Cross Section Develops Action Plans at PJM Demand Response Symposium Reuters 13 August 2008 Archived from the original on 19 February 2009 Retrieved 22 November 2008 Demand response can be achieved at the wholesale level with major energy users such as industrial plants curtailing power use and receiving payment for participating Willis H L Welch G V and Schrieber R R 2001 Aging Power Delivery Infrastructures New York Marcel Dekker Inc 551 pgs Randolph Kevin 21 July 2017 In order to integrate the grid disparate industries need to work together Daily Energy Insider Retrieved 3 August 2017 Smart Grid The New and Improved Power Grid A Survey IEEE Communications Surveys and Tutorials 2011 X Fang S Misra G Xue and D Yang doi 10 1109 SURV 2011 101911 00087 Alexandra Von Meier 2013 Electrical Engineer 137A Electric Power Systems Lecture 2 Introduction to Electric Power Systems Slide 33 Nunez Christina 14 December 2012 Who s Watching Privacy Concerns Persist as Smart Meters Roll Out Archived 2018 03 16 at the Wayback Machine National Geographic nationalgeographic com Retrieved 16 March 2018 U S Energy Independence and Security Act of 2007 Archived from the original on 19 December 2015 Retrieved 23 December 2007 DOE Provides up to 51 8 Million to Modernize the U S Electric Grid System Archived 20 September 2008 at the Wayback Machine 27 June 2007 U S Department of Energy DOE Kantamneni Abhilash Winkler Richelle Gauchia Lucia Pearce Joshua M 2016 free open access Emerging economic viability of grid defection in a northern climate using solar hybrid systems Energy Policy 95 378 389 doi 10 1016 j enpol 2016 05 013 Khalilpour R Vassallo A 2015 Leaving the grid An ambition or a real choice Energy Policy 82 207 221 doi 10 1016 j enpol 2015 03 005 Kumagai J 2014 The rise of the personal power plant IEEE Spectrum 51 6 54 59 doi 10 1109 mspec 2014 6821622 S2CID 36554641 The Economics of Grid Defection Rocky Mountain Institute The Economics of Grid Defection Archived from the original on 12 August 2016 Retrieved 13 August 2016 Andy Balaskovitz Net metering changes could drive people off grid Michigan researchers say Archived 15 June 2016 at the Wayback Machine MidWest Energy News Grid defection and why we don t want it 16 June 2015 External links edit nbsp Wikimedia Commons has media related to Power grids Map of U S generation and transmission Archived 2019 09 20 at the Wayback Machine U S electric system is made up of interconnections and balancing authorities U S Energy Information Administration EIA Open Infrastructure Map is a view of the world s hidden power infrastructure mapped in the OpenStreetMap database Retrieved from https en wikipedia org w index php title Electrical grid amp oldid 1186490939, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.