In electrical engineering, a switch is an electrical component that can disconnect or connect the conducting path in an electrical circuit, interrupting the electric current or diverting it from one conductor to another.[1][2] The most common type of switch is an electromechanical device consisting of one or more sets of movable electrical contacts connected to external circuits. When a pair of contacts is touching current can pass between them, while when the contacts are separated no current can flow.

Switches are made in many different configurations; they may have multiple sets of contacts controlled by the same knob or actuator, and the contacts may operate simultaneously, sequentially, or alternately. A switch may be operated manually, for example, a light switch or a keyboard button, or may function as a sensing element to sense the position of a machine part, liquid level, pressure, or temperature, such as a thermostat. Many specialized forms exist, such as the toggle switch, rotary switch, mercury switch, push-button switch, reversing switch, relay, and circuit breaker. A common use is control of lighting, where multiple switches may be wired into one circuit to allow convenient control of light fixtures. Switches in high-powered circuits must have special construction to prevent destructive arcing when they are opened.

Description edit

 
Electrical switches. Top, left to right: circuit breaker, mercury switch, wafer switch, DIP switch, surface mount switch, reed switch. Bottom, left to right: wall switch (U.S. style), miniature toggle switch, in‑line switch, push-button switch, rocker switch, microswitch.
 
Three push button switches (Tactile Switches). Major scale is inches.

The most familiar form of switch is a manually operated electromechanical device with one or more sets of electrical contacts, which are connected to external circuits. Each set of contacts can be in one of two states: either "closed" meaning the contacts are touching and electricity can flow between them, or "open", meaning the contacts are separated and the switch is nonconducting. The mechanism actuating the transition between these two states (open or closed) is usually (there are other types of actions) either an "alternate action" (flip the switch for continuous "on" or "off") or "momentary" (push for "on" and release for "off") type.

A switch may be directly manipulated by a human as a control signal to a system, such as a computer keyboard button, or to control power flow in a circuit, such as a light switch. Automatically operated switches can be used to control the motions of machines, for example, to indicate that a garage door has reached its full open position or that a machine tool is in a position to accept another workpiece. Switches may be operated by process variables such as pressure, temperature, flow, current, voltage, and force, acting as sensors in a process and used to automatically control a system. For example, a thermostat is a temperature-operated switch used to control a heating process. A switch that is operated by another electrical circuit is called a relay. Large switches may be remotely operated by a motor drive mechanism. Some switches are used to isolate electric power from a system, providing a visible point of isolation that can be padlocked if necessary to prevent accidental operation of a machine during maintenance, or to prevent electric shock.

An ideal switch would have no voltage drop when closed, and would have no limits on voltage or current rating. It would have zero rise time and fall time during state changes, and would change state without "bouncing" between on and off positions.

Practical switches fall short of this ideal; as the result of roughness and oxide films, they exhibit contact resistance, limits on the current and voltage they can handle, finite switching time, etc. The ideal switch is often used in circuit analysis as it greatly simplifies the system of equations to be solved, but this can lead to a less accurate solution. Theoretical treatment of the effects of non-ideal properties is required in the design of large networks of switches, as for example used in telephone exchanges.

Contacts edit

 
A toggle switch in the "on" position

In the simplest case, a switch has two conductive pieces, often metal, called contacts, connected to an external circuit, that touch to complete (make) the circuit, and separate to open (break) the circuit. The contact material is chosen for its resistance to corrosion, because most metals form insulating oxides that would prevent the switch from working. Contact materials are also chosen on the basis of electrical conductivity, hardness (resistance to abrasive wear), mechanical strength, low cost and low toxicity. The formation of oxide layers at contact surface, as well as surface roughness and contact pressure, determine the contact resistance, and wetting current of a mechanical switch. Sometimes the contacts are plated with noble metals, for their excellent conductivity and resistance to corrosion. They may be designed to wipe against each other to clean off any contamination. Nonmetallic conductors, such as conductive plastic, are sometimes used. To prevent the formation of insulating oxides, a minimum wetting current may be specified for a given switch design.

Contact terminology edit

 
Triple-pole single-throw (TPST or 3PST) knife switch used to short the windings of a 3‑phase wind turbine for braking purposes. Here the switch is shown in the open position.

In electronics, switches are classified according to the arrangement of their contacts. A pair of contacts is said to be "closed" when current can flow from one to the other. When the contacts are separated by an insulating air gap, they are said to be "open", and no current can flow between them at normal voltages. The terms "make" for closure of contacts and "break" for opening of contacts are also widely used.

The terms pole and throw are also used to describe switch contact variations. The number of "poles" is the number of electrically separate switches which are controlled by a single physical actuator. For example, a "2-pole" switch has two separate, parallel sets of contacts that open and close in unison via the same mechanism. The number of "throws" is the number of separate wiring path choices other than "open" that the switch can adopt for each pole. A single-throw switch has one pair of contacts that can either be closed or open. A double-throw switch has a contact that can be connected to either of two other contacts, a triple-throw has a contact which can be connected to one of three other contacts, etc.[3]

In a switch where the contacts remain in one state unless actuated, such as a push-button switch, the contacts can either be normally open (abbreviated "n.o." or "no") until closed by operation of the switch, or normally closed ("n.c." or "nc")[nb 1] and opened by the switch action. A switch with both types of contact is called a changeover switch or double-throw switch. These may be "make-before-break" ("MBB" or shorting) which momentarily connects both circuits, or may be "break-before-make" ("BBM" or non-shorting) which interrupts one circuit before closing the other.

These terms have given rise to abbreviations for the types of switch which are used in the electronics industry such as "single-pole, single-throw" (SPST) (the simplest type, "on or off") or "single-pole, double-throw" (SPDT), connecting either of two terminals to the common terminal. In electrical power wiring (i.e., house and building wiring by electricians), names generally involve the suffix "-way"; however, these terms differ between British English and American English (i.e., the terms two way and three way are used with different meanings).

Electronics specification and abbreviation Expansion
of
abbreviation
British
mains
wiring
name
American
electrical
wiring
name
Description Schematic Symbol IEC 60617
SPST
(1P1T)
Single pole, single throw One-way Two-way A simple on-off switch: The two terminals are either connected together or disconnected from each other. An example is a light switch.    
SPST-NO

Form A[4]

Single pole, single throw, normally open A simple on-off switch. The two terminals are normally disconnected (open) and are closed when the switch is activated. An example is a pushbutton switch.
SPST-NC
Form B[4]
Single pole, single throw, normally closed A simple on-off switch. The two terminals are normally connected together (closed) and are open when the switch is activated. An example is a pushbutton switch.  
SPDT
Form C[4]
Single pole, double throw Two-way Three-way A simple break-before-make changeover switch: C (COM, Common) is connected either to L1 or to L2.    
SPCO
SPTT, c.o.
Single pole changeover
or
single pole, centre off or
single pole, triple throw
    Similar to SPDT. Some suppliers use SPCO/SPTT for switches with a stable off position in the centre and SPDT for those without.  
        Serial switch or two-circuit switch[citation needed]    
DPST
(2P1T)
Double pole, single throw Double pole Double pole Equivalent to two SPST switches controlled by a single mechanism.    
DPDT
(2P2T)
Double pole, double throw Equivalent to two SPDT switches controlled by a single mechanism.    
DPCO Double pole changeover
or double pole, centre off
    Schematically equivalent to DPDT. Some suppliers use DPCO for switches with a stable center position and DPDT for those without. A DPDT/DPCO switch with a center position can be "off" in the center, not connected to either L1 or L2, or "on", connected to both L1 and L2 at the same time. The positions of such switches are commonly referenced as "on-off-on" and "on-on-on" respectively.  
    Intermediate switch Four-way switch DPDT switch internally wired for polarity-reversal applications: only four rather than six wires are brought outside the switch housing. Also called cross switch, crossover switch or reversing switch.[citation needed]    
2P6T Two pole, six throw Changeover switch with a COM (Common), which can connect to L1, L2, L3, L4, L5, or L6; with a second switch (2P, two pole) controlled by a single mechanism.    

Switches with larger numbers of poles or throws can be described by replacing the "S" or "D" with a number (e.g. 3PST, SP4T, etc.) or in some cases the letter "T" (for "triple") or "Q" (for "quadruple"). In the rest of this article the terms SPST, SPDT and intermediate will be used to avoid the ambiguity.

Contact bounce edit

Bounce edit

 
Oscilloscope snapshot showing voltage fluctuations caused by a switch bouncing between on and off (even swinging above Vhigh and below Vlow) many times over 2.6 ms before settling

Contact bounce (also called chatter) is a common problem with mechanical switches, relays and battery contacts, which arises as the result of electrical contact resistance (ECR) phenomena at interfaces. Switch and relay contacts are usually made of springy metals. When the contacts strike together, their momentum and elasticity act together to cause them to bounce apart one or more times before making steady contact. The result is a rapidly pulsed electric current instead of a clean transition from zero to full current. The effect is usually unimportant in power circuits, but causes problems in some analogue and logic circuits that respond fast enough to misinterpret the on‑off pulses as a data stream.[5] In the design of micro-contacts, controlling surface structure (surface roughness) and minimizing the formation of passivated layers on metallic surfaces are instrumental in inhibiting chatter.

In the Hammond organ, multiple wires are pressed together under the piano keys of the manuals. Their bouncing and non-synchronous closing of the switches is known as Hammond Click and compositions exist that use and emphasize this feature. Some electronic organs have a switchable replica of this sound effect.[6]

Debouncing edit

 
SPST switch bounce filter using a Schmitt trigger and capacitor

The effects of contact bounce can be eliminated by:

  • Use of mercury-wetted contacts, but these are now infrequently used because of the hazards of mercury.
  • Alternatively, contact circuit voltages can be low-pass filtered to reduce or eliminate multiple pulses from appearing.
  • In digital systems, multiple samples of the contact state can be taken at a low rate and examined for a steady sequence, so that contacts can settle before the contact level is considered reliable and acted upon. See Keyboard technology § Debouncing.
  • Bounce in SPDT ("single-pole, double-throw") switch contacts signals can be filtered out using an SR flip-flop (latch) or Schmitt trigger.

All of these methods are referred to as 'debouncing'.

Arcs and quenching edit

When the power being switched is sufficiently large, the electron flow across opening switch contacts is sufficient to ionize the air molecules across the tiny gap between the contacts as the switch is opened, forming a gas plasma, also known as an electric arc. The plasma is of low resistance and is able to sustain power flow, even with the separation distance between the switch contacts steadily increasing. The plasma is also very hot and is capable of eroding the metal surfaces of the switch contacts (the same true for vacuum switches). Electric current arcing causes significant degradation of the contacts and also significant electromagnetic interference (EMI), requiring the use of arc suppression methods.[7]

Where the voltage is sufficiently high, an arc can also form as the switch is closed and the contacts approach. If the voltage potential is sufficient to exceed the breakdown voltage of the air separating the contacts, an arc forms which is sustained until the switch closes completely and the switch surfaces make contact.

In either case, the standard method for minimizing arc formation and preventing contact damage is to use a fast-moving switch mechanism, typically using a spring-operated tipping-point mechanism to assure quick motion of switch contacts, regardless of the speed at which the switch control is operated by the user. Movement of the switch control lever applies tension to a spring until a tipping point is reached, and the contacts suddenly snap open or closed as the spring tension is released.

As the power being switched increases, other methods are used to minimize or prevent arc formation. A plasma is hot and will rise due to convection air currents. The arc can be quenched with a series of non-conductive blades spanning the distance between switch contacts, and as the arc rises, its length increases as it forms ridges rising into the spaces between the blades, until the arc is too long to stay sustained and is extinguished. A puffer may be used to blow a sudden high velocity burst of gas across the switch contacts, which rapidly extends the length of the arc to extinguish it quickly.

Extremely large switches often have switch contacts surrounded by something other than air to more rapidly extinguish the arc. For example, the switch contacts may operate in a vacuum, immersed in mineral oil, or in sulfur hexafluoride.

In AC power service, the current periodically passes through zero; this effect makes it harder to sustain an arc on opening. Manufacturers may rate switches with lower voltage or current rating when used in DC circuits.

Power switching edit

When a switch is designed to switch significant power, the transitional state of the switch as well as the ability to withstand continuous operating currents must be considered. When a switch is in the on state, its resistance is near zero and very little power is dropped in the contacts; when a switch is in the off state, its resistance is extremely high and even less power is dropped in the contacts. However, when the switch is flicked, the resistance must pass through a state where a quarter of the load's rated power[citation needed] (or worse if the load is not purely resistive) is briefly dropped in the switch.

For this reason, power switches intended to interrupt a load current have spring mechanisms to make sure the transition between on and off is as short as possible regardless of the speed at which the user moves the rocker.

Power switches usually come in two types. A momentary on‑off switch (such as on a laser pointer) usually takes the form of a button and only closes the circuit when the button is depressed. A regular on‑off switch (such as on a flashlight) has a constant on-off feature. Dual-action switches incorporate both of these features.

Inductive loads edit

When a strongly inductive load such as an electric motor is switched off, the current cannot drop instantaneously to zero; a spark will jump across the opening contacts. Switches for inductive loads must be rated to handle these cases. The spark will cause electromagnetic interference if not suppressed; a snubber network of a resistor and capacitor in series will quell the spark.[8]

Incandescent loads edit

 
A "T-rated" wall switch (the T is for Tungsten filament)[9] that is suited for incandescent loads

When turned on, an incandescent lamp draws a large inrush current of about ten times the steady-state current; as the filament heats up, its resistance rises and the current decreases to a steady-state value. A switch designed for an incandescent lamp load can withstand this inrush current.[9]

Wetting current edit

Wetting current is the minimum current needing to flow through a mechanical switch while it is operated to break through any film of oxidation that may have been deposited on the switch contacts.[10] The film of oxidation occurs often in areas with high humidity. Providing a sufficient amount of wetting current is a crucial step in designing systems that use delicate switches with small contact pressure as sensor inputs. Failing to do this might result in switches remaining electrically "open" due to contact oxidation.

Actuator edit

The moving part that applies the operating force to the contacts is called the actuator, and may be a toggle or dolly, a rocker, a push-button or any type of mechanical linkage (see photo).

Biased switches edit

A switch normally maintains its set position once operated. A biased switch contains a mechanism that springs it into another position when released by an operator. The momentary push-button switch is a type of biased switch. The most common type is a "push-to-make" (or normally-open or NO) switch, which makes contact when the button is pressed and breaks when the button is released. Each key of a computer keyboard, for example, is a normally-open "push-to-make" switch. A "push-to-break" (or normally-closed or NC) switch, on the other hand, breaks contact when the button is pressed and makes contact when it is released. An example of a push-to-break switch is a button used to release a door held closed by an electromagnet. The interior lamp of a household refrigerator is controlled by a switch that is held open when the door is closed.

Rotary switch edit

 
A three-deck stacked rotary switch. Any number of switching elements may be stacked in this manner, by using a longer shaft and additional spacing standoffs between each switching element.

A rotary switch operates with a twisting motion of the operating handle with at least two positions. One or more positions of the switch may be momentary (biased with a spring), requiring the operator to hold the switch in the position. Other positions may have a detent to hold the position when released. A rotary switch may have multiple levels or "decks" in order to allow it to control multiple circuits.

One form of rotary switch consists of a spindle or "rotor" that has a contact arm or "spoke" which projects from its surface like a cam. It has an array of terminals, arranged in a circle around the rotor, each of which serves as a contact for the "spoke" through which any one of a number of different electrical circuits can be connected to the rotor. The switch is layered to allow the use of multiple poles, each layer is equivalent to one pole. Usually such a switch has a detent mechanism so it "clicks" from one active position to another rather than stalls in an intermediate position. Thus a rotary switch provides greater pole and throw capabilities than simpler switches do.

Other types use a cam mechanism to operate multiple independent sets of contacts.

Rotary switches were used as channel selectors on television receivers until the early 1970s, as range selectors on electrical metering equipment, as band selectors on multi-band radios and other similar purposes. In industry, rotary switches are used for control of measuring instruments, switchgear, or in control circuits. For example, a radio controlled overhead crane may have a large multi-circuit rotary switch to transfer hard-wired control signals from the local manual controls in the cab to the outputs of the remote control receiver.

Toggle switch edit

 
A toggle switch with four inputs and outputs
 
Bank of toggle switches on a Data General Nova minicomputer front panel
 
Toggle switches with the shared cover preventing certain forbidden combinations

A toggle switch or tumbler switch is a class of electrical switches that are manually actuated by a mechanical lever, handle, or rocking mechanism.

Toggle switches are available in many different styles and sizes, and are used in numerous applications. Many are designed to provide the simultaneous actuation of multiple sets of electrical contacts, or the control of large amounts of electric current or mains voltages.

The word "toggle" is a reference to a kind of mechanism or joint consisting of two arms, which are almost in line with each other, connected with an elbow-like pivot. However, the phrase "toggle switch" is applied to a switch with a short handle and a positive snap-action, whether it actually contains a toggle mechanism or not. Similarly, a switch where a definitive click is heard, is called a "positive on-off switch".[11] A very common use of this type of switch is to switch lights or other electrical equipment on or off. Multiple toggle switches may be mechanically interlocked to prevent forbidden combinations.

In some contexts, particularly computing, a toggle switch, or the action of toggling, is understood in the different sense of a mechanical or software switch that alternates between two states each time it is activated, regardless of mechanical construction. For example, the caps lock key on a computer causes all letters to be generated in capitals after it is pressed once; pressing it again reverts to lower-case letters.

Special types edit

 
Opened float switch of a dirty-water pump

Switches can be designed to respond to any type of mechanical stimulus: for example, vibration (the trembler switch), tilt, air pressure, fluid level (a float switch), the turning of a key (key switch), linear or rotary movement (a limit switch or microswitch), or presence of a magnetic field (the reed switch). Many switches are operated automatically by changes in some environmental condition or by motion of machinery. A limit switch is used, for example, in machine tools to interlock operation with the proper position of tools. In heating or cooling systems a sail switch ensures that air flow is adequate in a duct. Pressure switches respond to fluid pressure.

Mercury tilt switch edit

The mercury switch consists of a drop of mercury inside a glass bulb with two or more contacts. The two contacts pass through the glass, and are connected by the mercury when the bulb is tilted to make the mercury roll on to them.

This type of switch performs much better than the ball tilt switch, as the liquid metal connection is unaffected by dirt, debris and oxidation, it wets the contacts ensuring a very low resistance bounce-free connection, and movement and vibration do not produce a poor contact. These types can be used for precision works.

It can also be used where arcing is dangerous (such as in the presence of explosive vapour) as the entire unit is sealed.

Knife switch edit

 
A high-voltage disconnect switch used in an electrical substation. Such switches are used mostly to isolate circuits, and usually cannot break load current. High-voltage switches are available for the highest transmission voltages, up to 1 million volts. This switch is gang-operated so that all three phases are interrupted at the same time.

Knife switches consist of a flat metal blade, hinged at one end, with an insulating handle for operation, and a fixed contact. When the switch is closed, current flows through the hinged pivot and blade and through the fixed contact. Such switches are usually not enclosed. The knife and contacts are typically formed of copper, steel, or brass, depending on the application. Fixed contacts may be backed up with a spring. Several parallel blades can be operated at the same time by one handle. The parts may be mounted on an insulating base with terminals for wiring, or may be directly bolted to an insulated switch board in a large assembly. Since the electrical contacts are exposed, the switch is used only where people cannot accidentally come in contact with the switch or where the voltage is so low as to not present a hazard.

Knife switches are made in many sizes from miniature switches to large devices used to carry thousands of amperes. In electrical transmission and distribution, gang-operated switches are used in circuits up to the highest voltages.

The disadvantages of the knife switch are the slow opening speed and the proximity of the operator to exposed live parts. Metal-enclosed safety disconnect switches are used for isolation of circuits in industrial power distribution. Sometimes spring-loaded auxiliary blades are fitted which momentarily carry the full current during opening, then quickly part to rapidly extinguish the arc.

Reversing switch edit

A DPDT switch has six connections, but since polarity reversal is a very common usage of DPDT switches, some variations of the DPDT switch are internally wired specifically for polarity reversal. These crossover switches only have four terminals rather than six. Two of the terminals are inputs and two are outputs. When connected to a battery or other DC source, the 4-way switch selects from either normal or reversed polarity. Such switches can also be used as intermediate switches in a multiway switching system for control of lamps by more than two switches.

Light switches edit

In building wiring, light switches are installed at convenient locations to control lighting and occasionally other circuits. By use of multiple-pole switches, multiway switching control of a lamp can be obtained from two or more places, such as the ends of a corridor or stairwell. A wireless light switch allows remote control of lamps for convenience; some lamps include a touch switch which electronically controls the lamp if touched anywhere. In public buildings several types of vandal resistant switches are used to prevent unauthorized use.

Slide switches edit

Slide switches are mechanical switches using a slider that moves (slides) from the open (off) position to the closed (on) position.

Electronic switches edit

The term switch has since spread to a variety of solid state electronics that perform a switching function, but which are controlled electronically by active devices rather than purely mechanically. These are categorized in the article electronic switch. Electromechanical switches (such as the traditional relay, electromechanical crossbar, and Strowger switch) bridge the categorization.

Other switches edit

See also edit

Notes edit

  1. ^ The abbreviation N.C. (for "Normally closed") is also used to mean "Not connected" in the context of connector or part pins.

References edit

  1. ^ "Switch". The Free Dictionary. Farlex. 2008. Retrieved 2008-12-27.
  2. ^ "Switch". The American Heritage Dictionary, College Edition. Houghton Mifflin. 1979. p. 1301.
  3. ^ RF Switch 2011-04-23 at the Wayback Machine Explanation by Herley – General Microwave
  4. ^ a b c . Archived from the original on 2017-07-05.
  5. ^ Walker, PMB, Chambers Science and Technology Dictionary, Edinburgh, 1988, ISBN 1-85296-150-3
  6. ^ Features of Technics E-33
  7. ^ "Lab Note #105 Contact Life – Unsuppressed vs. Suppressed Arcing" (PDF). Arc Suppression Technologies. April 2011. from the original on December 3, 2013. Retrieved February 5, 2012. (3.6 Mb)
  8. ^ "Cornell Dubilier Capacitors - CDE (En-US)" (PDF). (PDF) from the original on 2017-02-15. Retrieved 2017-10-05.
  9. ^ a b Fardo, Stephen; Patrick, Dale (2009-01-01). Electrical Power Systems Technology. The Fairmont Press, Inc. p. 337. ISBN 9780881735864. from the original on 2017-12-24. Retrieved 2015-01-26.
  10. ^ Gregory K. McMillan (ed) Process/Industrial Instruments and Controls Handbook (5th Edition) (McGraw Hill, 1999) ISBN 0-07-012582-1 page 7.26
  11. ^ Gladstone, Bernard (1978). The New York Times complete manual of home repair. Times Books. p. 399. ISBN 9780812908923. from the original on 2014-03-29.

External links edit

  •   Media related to Electric switches at Wikimedia Commons

switch, this, article, about, electrical, component, video, game, console, nintendo, nintendo, other, uses, disambiguation, toggle, button, redirects, here, graphical, widget, cycle, button, electrical, engineering, switch, electrical, component, that, disconn. This article is about an electrical component For the video game console by Nintendo see Nintendo Switch For other uses see Switch disambiguation Toggle button redirects here For the graphical widget see Cycle button In electrical engineering a switch is an electrical component that can disconnect or connect the conducting path in an electrical circuit interrupting the electric current or diverting it from one conductor to another 1 2 The most common type of switch is an electromechanical device consisting of one or more sets of movable electrical contacts connected to external circuits When a pair of contacts is touching current can pass between them while when the contacts are separated no current can flow Switches are made in many different configurations they may have multiple sets of contacts controlled by the same knob or actuator and the contacts may operate simultaneously sequentially or alternately A switch may be operated manually for example a light switch or a keyboard button or may function as a sensing element to sense the position of a machine part liquid level pressure or temperature such as a thermostat Many specialized forms exist such as the toggle switch rotary switch mercury switch push button switch reversing switch relay and circuit breaker A common use is control of lighting where multiple switches may be wired into one circuit to allow convenient control of light fixtures Switches in high powered circuits must have special construction to prevent destructive arcing when they are opened Contents 1 Description 2 Contacts 2 1 Contact terminology 2 2 Contact bounce 2 2 1 Bounce 2 2 2 Debouncing 2 3 Arcs and quenching 2 4 Power switching 2 5 Inductive loads 2 6 Incandescent loads 2 7 Wetting current 3 Actuator 3 1 Biased switches 3 2 Rotary switch 3 3 Toggle switch 4 Special types 4 1 Mercury tilt switch 4 2 Knife switch 4 3 Reversing switch 5 Light switches 6 Slide switches 7 Electronic switches 8 Other switches 9 See also 10 Notes 11 References 12 External linksDescription edit nbsp Electrical switches Top left to right circuit breaker mercury switch wafer switch DIP switch surface mount switch reed switch Bottom left to right wall switch U S style miniature toggle switch in line switch push button switch rocker switch microswitch nbsp Three push button switches Tactile Switches Major scale is inches The most familiar form of switch is a manually operated electromechanical device with one or more sets of electrical contacts which are connected to external circuits Each set of contacts can be in one of two states either closed meaning the contacts are touching and electricity can flow between them or open meaning the contacts are separated and the switch is nonconducting The mechanism actuating the transition between these two states open or closed is usually there are other types of actions either an alternate action flip the switch for continuous on or off or momentary push for on and release for off type A switch may be directly manipulated by a human as a control signal to a system such as a computer keyboard button or to control power flow in a circuit such as a light switch Automatically operated switches can be used to control the motions of machines for example to indicate that a garage door has reached its full open position or that a machine tool is in a position to accept another workpiece Switches may be operated by process variables such as pressure temperature flow current voltage and force acting as sensors in a process and used to automatically control a system For example a thermostat is a temperature operated switch used to control a heating process A switch that is operated by another electrical circuit is called a relay Large switches may be remotely operated by a motor drive mechanism Some switches are used to isolate electric power from a system providing a visible point of isolation that can be padlocked if necessary to prevent accidental operation of a machine during maintenance or to prevent electric shock An ideal switch would have no voltage drop when closed and would have no limits on voltage or current rating It would have zero rise time and fall time during state changes and would change state without bouncing between on and off positions Practical switches fall short of this ideal as the result of roughness and oxide films they exhibit contact resistance limits on the current and voltage they can handle finite switching time etc The ideal switch is often used in circuit analysis as it greatly simplifies the system of equations to be solved but this can lead to a less accurate solution Theoretical treatment of the effects of non ideal properties is required in the design of large networks of switches as for example used in telephone exchanges Contacts edit nbsp A toggle switch in the on positionIn the simplest case a switch has two conductive pieces often metal called contacts connected to an external circuit that touch to complete make the circuit and separate to open break the circuit The contact material is chosen for its resistance to corrosion because most metals form insulating oxides that would prevent the switch from working Contact materials are also chosen on the basis of electrical conductivity hardness resistance to abrasive wear mechanical strength low cost and low toxicity The formation of oxide layers at contact surface as well as surface roughness and contact pressure determine the contact resistance and wetting current of a mechanical switch Sometimes the contacts are plated with noble metals for their excellent conductivity and resistance to corrosion They may be designed to wipe against each other to clean off any contamination Nonmetallic conductors such as conductive plastic are sometimes used To prevent the formation of insulating oxides a minimum wetting current may be specified for a given switch design Contact terminology edit nbsp Triple pole single throw TPST or 3PST knife switch used to short the windings of a 3 phase wind turbine for braking purposes Here the switch is shown in the open position In electronics switches are classified according to the arrangement of their contacts A pair of contacts is said to be closed when current can flow from one to the other When the contacts are separated by an insulating air gap they are said to be open and no current can flow between them at normal voltages The terms make for closure of contacts and break for opening of contacts are also widely used The terms pole and throw are also used to describe switch contact variations The number of poles is the number of electrically separate switches which are controlled by a single physical actuator For example a 2 pole switch has two separate parallel sets of contacts that open and close in unison via the same mechanism The number of throws is the number of separate wiring path choices other than open that the switch can adopt for each pole A single throw switch has one pair of contacts that can either be closed or open A double throw switch has a contact that can be connected to either of two other contacts a triple throw has a contact which can be connected to one of three other contacts etc 3 In a switch where the contacts remain in one state unless actuated such as a push button switch the contacts can either be normally open abbreviated n o or no until closed by operation of the switch or normally closed n c or nc nb 1 and opened by the switch action A switch with both types of contact is called a changeover switch or double throw switch These may be make before break MBB or shorting which momentarily connects both circuits or may be break before make BBM or non shorting which interrupts one circuit before closing the other These terms have given rise to abbreviations for the types of switch which are used in the electronics industry such as single pole single throw SPST the simplest type on or off or single pole double throw SPDT connecting either of two terminals to the common terminal In electrical power wiring i e house and building wiring by electricians names generally involve the suffix way however these terms differ between British English and American English i e the terms two way and three way are used with different meanings Electronics specification and abbreviation Expansion ofabbreviation Britishmains wiringname American electricalwiringname Description Schematic Symbol IEC 60617SPST 1P1T Single pole single throw One way Two way A simple on off switch The two terminals are either connected together or disconnected from each other An example is a light switch nbsp nbsp SPST NO Form A 4 Single pole single throw normally open A simple on off switch The two terminals are normally disconnected open and are closed when the switch is activated An example is a pushbutton switch SPST NCForm B 4 Single pole single throw normally closed A simple on off switch The two terminals are normally connected together closed and are open when the switch is activated An example is a pushbutton switch nbsp SPDTForm C 4 Single pole double throw Two way Three way A simple break before make changeover switch C COM Common is connected either to L1 or to L2 nbsp nbsp SPCOSPTT c o Single pole changeoverorsingle pole centre off orsingle pole triple throw Similar to SPDT Some suppliers use SPCO SPTT for switches with a stable off position in the centre and SPDT for those without Serial switch or two circuit switch citation needed nbsp DPST 2P1T Double pole single throw Double pole Double pole Equivalent to two SPST switches controlled by a single mechanism nbsp nbsp DPDT 2P2T Double pole double throw Equivalent to two SPDT switches controlled by a single mechanism nbsp nbsp DPCO Double pole changeover or double pole centre off Schematically equivalent to DPDT Some suppliers use DPCO for switches with a stable center position and DPDT for those without A DPDT DPCO switch with a center position can be off in the center not connected to either L1 or L2 or on connected to both L1 and L2 at the same time The positions of such switches are commonly referenced as on off on and on on on respectively Intermediate switch Four way switch DPDT switch internally wired for polarity reversal applications only four rather than six wires are brought outside the switch housing Also called cross switch crossover switch or reversing switch citation needed nbsp nbsp 2P6T Two pole six throw Changeover switch with a COM Common which can connect to L1 L2 L3 L4 L5 or L6 with a second switch 2P two pole controlled by a single mechanism nbsp Switches with larger numbers of poles or throws can be described by replacing the S or D with a number e g 3PST SP4T etc or in some cases the letter T for triple or Q for quadruple In the rest of this article the terms SPST SPDT and intermediate will be used to avoid the ambiguity Contact bounce edit Bounce edit nbsp Oscilloscope snapshot showing voltage fluctuations caused by a switch bouncing between on and off even swinging above Vhigh and below Vlow many times over 2 6 ms before settlingContact bounce also called chatter is a common problem with mechanical switches relays and battery contacts which arises as the result of electrical contact resistance ECR phenomena at interfaces Switch and relay contacts are usually made of springy metals When the contacts strike together their momentum and elasticity act together to cause them to bounce apart one or more times before making steady contact The result is a rapidly pulsed electric current instead of a clean transition from zero to full current The effect is usually unimportant in power circuits but causes problems in some analogue and logic circuits that respond fast enough to misinterpret the on off pulses as a data stream 5 In the design of micro contacts controlling surface structure surface roughness and minimizing the formation of passivated layers on metallic surfaces are instrumental in inhibiting chatter In the Hammond organ multiple wires are pressed together under the piano keys of the manuals Their bouncing and non synchronous closing of the switches is known as Hammond Click and compositions exist that use and emphasize this feature Some electronic organs have a switchable replica of this sound effect 6 Debouncing edit nbsp SPST switch bounce filter using a Schmitt trigger and capacitorThe effects of contact bounce can be eliminated by Use of mercury wetted contacts but these are now infrequently used because of the hazards of mercury Alternatively contact circuit voltages can be low pass filtered to reduce or eliminate multiple pulses from appearing In digital systems multiple samples of the contact state can be taken at a low rate and examined for a steady sequence so that contacts can settle before the contact level is considered reliable and acted upon See Keyboard technology Debouncing Bounce in SPDT single pole double throw switch contacts signals can be filtered out using an SR flip flop latch or Schmitt trigger All of these methods are referred to as debouncing Arcs and quenching edit When the power being switched is sufficiently large the electron flow across opening switch contacts is sufficient to ionize the air molecules across the tiny gap between the contacts as the switch is opened forming a gas plasma also known as an electric arc The plasma is of low resistance and is able to sustain power flow even with the separation distance between the switch contacts steadily increasing The plasma is also very hot and is capable of eroding the metal surfaces of the switch contacts the same true for vacuum switches Electric current arcing causes significant degradation of the contacts and also significant electromagnetic interference EMI requiring the use of arc suppression methods 7 Where the voltage is sufficiently high an arc can also form as the switch is closed and the contacts approach If the voltage potential is sufficient to exceed the breakdown voltage of the air separating the contacts an arc forms which is sustained until the switch closes completely and the switch surfaces make contact In either case the standard method for minimizing arc formation and preventing contact damage is to use a fast moving switch mechanism typically using a spring operated tipping point mechanism to assure quick motion of switch contacts regardless of the speed at which the switch control is operated by the user Movement of the switch control lever applies tension to a spring until a tipping point is reached and the contacts suddenly snap open or closed as the spring tension is released As the power being switched increases other methods are used to minimize or prevent arc formation A plasma is hot and will rise due to convection air currents The arc can be quenched with a series of non conductive blades spanning the distance between switch contacts and as the arc rises its length increases as it forms ridges rising into the spaces between the blades until the arc is too long to stay sustained and is extinguished A puffer may be used to blow a sudden high velocity burst of gas across the switch contacts which rapidly extends the length of the arc to extinguish it quickly Extremely large switches often have switch contacts surrounded by something other than air to more rapidly extinguish the arc For example the switch contacts may operate in a vacuum immersed in mineral oil or in sulfur hexafluoride In AC power service the current periodically passes through zero this effect makes it harder to sustain an arc on opening Manufacturers may rate switches with lower voltage or current rating when used in DC circuits Power switching edit See also Power management integrated circuit Solid state electronics and Solid state relay When a switch is designed to switch significant power the transitional state of the switch as well as the ability to withstand continuous operating currents must be considered When a switch is in the on state its resistance is near zero and very little power is dropped in the contacts when a switch is in the off state its resistance is extremely high and even less power is dropped in the contacts However when the switch is flicked the resistance must pass through a state where a quarter of the load s rated power citation needed or worse if the load is not purely resistive is briefly dropped in the switch For this reason power switches intended to interrupt a load current have spring mechanisms to make sure the transition between on and off is as short as possible regardless of the speed at which the user moves the rocker Power switches usually come in two types A momentary on off switch such as on a laser pointer usually takes the form of a button and only closes the circuit when the button is depressed A regular on off switch such as on a flashlight has a constant on off feature Dual action switches incorporate both of these features Inductive loads edit When a strongly inductive load such as an electric motor is switched off the current cannot drop instantaneously to zero a spark will jump across the opening contacts Switches for inductive loads must be rated to handle these cases The spark will cause electromagnetic interference if not suppressed a snubber network of a resistor and capacitor in series will quell the spark 8 Incandescent loads edit nbsp A T rated wall switch the T is for Tungsten filament 9 that is suited for incandescent loadsWhen turned on an incandescent lamp draws a large inrush current of about ten times the steady state current as the filament heats up its resistance rises and the current decreases to a steady state value A switch designed for an incandescent lamp load can withstand this inrush current 9 Wetting current edit Main article Wetting current Wetting current is the minimum current needing to flow through a mechanical switch while it is operated to break through any film of oxidation that may have been deposited on the switch contacts 10 The film of oxidation occurs often in areas with high humidity Providing a sufficient amount of wetting current is a crucial step in designing systems that use delicate switches with small contact pressure as sensor inputs Failing to do this might result in switches remaining electrically open due to contact oxidation Actuator editThe moving part that applies the operating force to the contacts is called the actuator and may be a toggle or dolly a rocker a push button or any type of mechanical linkage see photo Biased switches edit A switch normally maintains its set position once operated A biased switch contains a mechanism that springs it into another position when released by an operator The momentary push button switch is a type of biased switch The most common type is a push to make or normally open or NO switch which makes contact when the button is pressed and breaks when the button is released Each key of a computer keyboard for example is a normally open push to make switch A push to break or normally closed or NC switch on the other hand breaks contact when the button is pressed and makes contact when it is released An example of a push to break switch is a button used to release a door held closed by an electromagnet The interior lamp of a household refrigerator is controlled by a switch that is held open when the door is closed Rotary switch edit Main article Rotary switch nbsp A three deck stacked rotary switch Any number of switching elements may be stacked in this manner by using a longer shaft and additional spacing standoffs between each switching element A rotary switch operates with a twisting motion of the operating handle with at least two positions One or more positions of the switch may be momentary biased with a spring requiring the operator to hold the switch in the position Other positions may have a detent to hold the position when released A rotary switch may have multiple levels or decks in order to allow it to control multiple circuits One form of rotary switch consists of a spindle or rotor that has a contact arm or spoke which projects from its surface like a cam It has an array of terminals arranged in a circle around the rotor each of which serves as a contact for the spoke through which any one of a number of different electrical circuits can be connected to the rotor The switch is layered to allow the use of multiple poles each layer is equivalent to one pole Usually such a switch has a detent mechanism so it clicks from one active position to another rather than stalls in an intermediate position Thus a rotary switch provides greater pole and throw capabilities than simpler switches do Other types use a cam mechanism to operate multiple independent sets of contacts Rotary switches were used as channel selectors on television receivers until the early 1970s as range selectors on electrical metering equipment as band selectors on multi band radios and other similar purposes In industry rotary switches are used for control of measuring instruments switchgear or in control circuits For example a radio controlled overhead crane may have a large multi circuit rotary switch to transfer hard wired control signals from the local manual controls in the cab to the outputs of the remote control receiver Toggle switch edit nbsp A toggle switch with four inputs and outputs nbsp Bank of toggle switches on a Data General Nova minicomputer front panel nbsp Toggle switches with the shared cover preventing certain forbidden combinationsA toggle switch or tumbler switch is a class of electrical switches that are manually actuated by a mechanical lever handle or rocking mechanism Toggle switches are available in many different styles and sizes and are used in numerous applications Many are designed to provide the simultaneous actuation of multiple sets of electrical contacts or the control of large amounts of electric current or mains voltages The word toggle is a reference to a kind of mechanism or joint consisting of two arms which are almost in line with each other connected with an elbow like pivot However the phrase toggle switch is applied to a switch with a short handle and a positive snap action whether it actually contains a toggle mechanism or not Similarly a switch where a definitive click is heard is called a positive on off switch 11 A very common use of this type of switch is to switch lights or other electrical equipment on or off Multiple toggle switches may be mechanically interlocked to prevent forbidden combinations In some contexts particularly computing a toggle switch or the action of toggling is understood in the different sense of a mechanical or software switch that alternates between two states each time it is activated regardless of mechanical construction For example the caps lock key on a computer causes all letters to be generated in capitals after it is pressed once pressing it again reverts to lower case letters Special types edit nbsp Opened float switch of a dirty water pumpSwitches can be designed to respond to any type of mechanical stimulus for example vibration the trembler switch tilt air pressure fluid level a float switch the turning of a key key switch linear or rotary movement a limit switch or microswitch or presence of a magnetic field the reed switch Many switches are operated automatically by changes in some environmental condition or by motion of machinery A limit switch is used for example in machine tools to interlock operation with the proper position of tools In heating or cooling systems a sail switch ensures that air flow is adequate in a duct Pressure switches respond to fluid pressure Mercury tilt switch edit Main article Mercury switch The mercury switch consists of a drop of mercury inside a glass bulb with two or more contacts The two contacts pass through the glass and are connected by the mercury when the bulb is tilted to make the mercury roll on to them This type of switch performs much better than the ball tilt switch as the liquid metal connection is unaffected by dirt debris and oxidation it wets the contacts ensuring a very low resistance bounce free connection and movement and vibration do not produce a poor contact These types can be used for precision works It can also be used where arcing is dangerous such as in the presence of explosive vapour as the entire unit is sealed Knife switch edit Main article Knife switch nbsp A high voltage disconnect switch used in an electrical substation Such switches are used mostly to isolate circuits and usually cannot break load current High voltage switches are available for the highest transmission voltages up to 1 million volts This switch is gang operated so that all three phases are interrupted at the same time Knife switches consist of a flat metal blade hinged at one end with an insulating handle for operation and a fixed contact When the switch is closed current flows through the hinged pivot and blade and through the fixed contact Such switches are usually not enclosed The knife and contacts are typically formed of copper steel or brass depending on the application Fixed contacts may be backed up with a spring Several parallel blades can be operated at the same time by one handle The parts may be mounted on an insulating base with terminals for wiring or may be directly bolted to an insulated switch board in a large assembly Since the electrical contacts are exposed the switch is used only where people cannot accidentally come in contact with the switch or where the voltage is so low as to not present a hazard Knife switches are made in many sizes from miniature switches to large devices used to carry thousands of amperes In electrical transmission and distribution gang operated switches are used in circuits up to the highest voltages The disadvantages of the knife switch are the slow opening speed and the proximity of the operator to exposed live parts Metal enclosed safety disconnect switches are used for isolation of circuits in industrial power distribution Sometimes spring loaded auxiliary blades are fitted which momentarily carry the full current during opening then quickly part to rapidly extinguish the arc Reversing switch editA DPDT switch has six connections but since polarity reversal is a very common usage of DPDT switches some variations of the DPDT switch are internally wired specifically for polarity reversal These crossover switches only have four terminals rather than six Two of the terminals are inputs and two are outputs When connected to a battery or other DC source the 4 way switch selects from either normal or reversed polarity Such switches can also be used as intermediate switches in a multiway switching system for control of lamps by more than two switches See also Commutator electric Auto polarity digital multimeter and H bridgeLight switches editMain article Light switch In building wiring light switches are installed at convenient locations to control lighting and occasionally other circuits By use of multiple pole switches multiway switching control of a lamp can be obtained from two or more places such as the ends of a corridor or stairwell A wireless light switch allows remote control of lamps for convenience some lamps include a touch switch which electronically controls the lamp if touched anywhere In public buildings several types of vandal resistant switches are used to prevent unauthorized use Slide switches editSlide switches are mechanical switches using a slider that moves slides from the open off position to the closed on position Electronic switches editMain article Electronic switch See also Digital electronics MOSFET and Transistor Transistor as a switch The term switch has since spread to a variety of solid state electronics that perform a switching function but which are controlled electronically by active devices rather than purely mechanically These are categorized in the article electronic switch Electromechanical switches such as the traditional relay electromechanical crossbar and Strowger switch bridge the categorization Other switches editCentrifugal switch Company switch Crossbar switch Dead man s switch Fireman s switch Hall effect switch Inertial switch Isolator switch Key switch Kill switch Latching switch Light switch Load control switch Membrane switch MEMS switch Optical switch Piezo switch Pull switch Push switch Railroad switch Sense switch Slotted optical switch Stepping switch Strowger switch Thermal switch Time switch Touch switch Transfer switch Wire switches Zero speed switchSee also editCircuit breaker Commutator electric Contact resistance DIN rail Electric switchboard Fuse cutout RF switch matrix Switch access SwitchgearNotes edit The abbreviation N C for Normally closed is also used to mean Not connected in the context of connector or part pins References edit Switch The Free Dictionary Farlex 2008 Retrieved 2008 12 27 Switch The American Heritage Dictionary College Edition Houghton Mifflin 1979 p 1301 RF Switch Archived 2011 04 23 at the Wayback Machine Explanation by Herley General Microwave a b c Engineer s Relay Handbook 5th edition Chapter 1 6 by RSIA formerly NARM Archived from the original on 2017 07 05 Walker PMB Chambers Science and Technology Dictionary Edinburgh 1988 ISBN 1 85296 150 3 Features of Technics E 33 Lab Note 105 Contact Life Unsuppressed vs Suppressed Arcing PDF Arc Suppression Technologies April 2011 Archived from the original on December 3 2013 Retrieved February 5 2012 3 6 Mb Cornell Dubilier Capacitors CDE En US PDF Archived PDF from the original on 2017 02 15 Retrieved 2017 10 05 a b Fardo Stephen Patrick Dale 2009 01 01 Electrical Power Systems Technology The Fairmont Press Inc p 337 ISBN 9780881735864 Archived from the original on 2017 12 24 Retrieved 2015 01 26 Gregory K McMillan ed Process Industrial Instruments and Controls Handbook 5th Edition McGraw Hill 1999 ISBN 0 07 012582 1 page 7 26 Gladstone Bernard 1978 The New York Times complete manual of home repair Times Books p 399 ISBN 9780812908923 Archived from the original on 2014 03 29 External links edit nbsp Media related to Electric switches at Wikimedia Commons Retrieved from https en wikipedia org w index php title Switch amp oldid 1207576179, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.