fbpx
Wikipedia

Coaxial cable

Coaxial cable, or coax (pronounced /ˈk.æks/) is a type of electrical cable consisting of an inner conductor surrounded by a concentric conducting shield, with the two separated by a dielectric (insulating material); many coaxial cables also have a protective outer sheath or jacket. The term coaxial refers to the inner conductor and the outer shield sharing a geometric axis.

RG-59 flexible coaxial cable composed of:
  1. Outer plastic sheath
  2. Woven copper shield
  3. Inner dielectric insulator
  4. Copper core

Coaxial cable is a type of transmission line, used to carry high-frequency electrical signals with low losses. It is used in such applications as telephone trunk lines, broadband internet networking cables, high-speed computer data busses, cable television signals, and connecting radio transmitters and receivers to their antennas. It differs from other shielded cables because the dimensions of the cable and connectors are controlled to give a precise, constant conductor spacing, which is needed for it to function efficiently as a transmission line.

In his 1880 British patent, Oliver Heaviside showed how coaxial cable could eliminate signal interference between parallel cables.

Coaxial cable was used in the first (1858) and following transatlantic cable installations, but its theory was not described until 1880 by English physicist, engineer, and mathematician Oliver Heaviside, who patented the design in that year (British patent No. 1,407).[1]

Applications

Coaxial cable is used as a transmission line for radio frequency signals. Its applications include feedlines connecting radio transmitters and receivers to their antennas, computer network (e.g., Ethernet) connections, digital audio (S/PDIF), and distribution of cable television signals. One advantage of coaxial over other types of radio transmission line is that in an ideal coaxial cable the electromagnetic field carrying the signal exists only in the space between the inner and outer conductors. This allows coaxial cable runs to be installed next to metal objects such as gutters without the power losses that occur in other types of transmission lines. Coaxial cable also provides protection of the signal from external electromagnetic interference.

Description

 
Coaxial cable cutaway (not to scale)

Coaxial cable conducts electrical signal using an inner conductor (usually a solid copper, stranded copper or copper plated steel wire) surrounded by an insulating layer and all enclosed by a shield, typically one to four layers of woven metallic braid and metallic tape. The cable is protected by an outer insulating jacket. Normally, the outside of the shield is kept at ground potential and a signal carrying voltage is applied to the center conductor. When using differential signaling, coaxial cable provides an advantage of equal push-pull currents on the inner conductor and inside of the outer conductor that restrict the signal's electric and magnetic fields to the dielectric, with little leakage outside the shield.[citation needed] Further, electric and magnetic fields outside the cable are largely kept from interfering with signals inside the cable, if unequal currents are filtered out at the receiving end of the line. This property makes coaxial cable a good choice both for carrying weak signals that cannot tolerate interference from the environment, and for stronger electrical signals that must not be allowed to radiate or couple into adjacent structures or circuits.[2] Larger diameter cables and cables with multiple shields have less leakage.

Common applications of coaxial cable include video and CATV distribution, RF and microwave transmission, and computer and instrumentation data connections.[3]

The characteristic impedance of the cable (Z0) is determined by the dielectric constant of the inner insulator and the radii of the inner and outer conductors. In radio frequency systems, where the cable length is comparable to the wavelength of the signals transmitted, a uniform cable characteristic impedance is important to minimize loss. The source and load impedances are chosen to match the impedance of the cable to ensure maximum power transfer and minimum standing wave ratio. Other important properties of coaxial cable include attenuation as a function of frequency, voltage handling capability, and shield quality.[2]

Construction

Coaxial cable design choices affect physical size, frequency performance, attenuation, power handling capabilities, flexibility, strength, and cost. The inner conductor might be solid or stranded; stranded is more flexible. To get better high-frequency performance, the inner conductor may be silver-plated. Copper-plated steel wire is often used as an inner conductor for cable used in the cable TV industry.[4]

The insulator surrounding the inner conductor may be solid plastic, a foam plastic, or air with spacers supporting the inner wire. The properties of the dielectric insulator determine some of the electrical properties of the cable. A common choice is a solid polyethylene (PE) insulator, used in lower-loss cables. Solid Teflon (PTFE) is also used as an insulator, and exclusively in plenum-rated cables.[citation needed] Some coaxial lines use air (or some other gas) and have spacers to keep the inner conductor from touching the shield.

Many conventional coaxial cables use braided copper wire forming the shield. This allows the cable to be flexible, but it also means there are gaps in the shield layer, and the inner dimension of the shield varies slightly because the braid cannot be flat. Sometimes the braid is silver-plated. For better shield performance, some cables have a double-layer shield.[4] The shield might be just two braids, but it is more common now to have a thin foil shield covered by a wire braid. Some cables may invest in more than two shield layers, such as "quad-shield", which uses four alternating layers of foil and braid. Other shield designs sacrifice flexibility for better performance; some shields are a solid metal tube. Those cables cannot be bent sharply, as the shield will kink, causing losses in the cable. When a foil shield is used a small wire conductor incorporated into the foil makes soldering the shield termination easier.[examples needed]

For high-power radio-frequency transmission up to about 1 GHz, coaxial cable with a solid copper outer conductor is available in sizes of 0.25 inch upward. The outer conductor is corrugated like a bellows to permit flexibility and the inner conductor is held in position by a plastic spiral to approximate an air dielectric.[4] One brand name for such cable is Heliax.[5]

Coaxial cables require an internal structure of an insulating (dielectric) material to maintain the spacing between the center conductor and shield. The dielectric losses increase in this order: Ideal dielectric (no loss), vacuum, air, polytetrafluoroethylene (PTFE), polyethylene foam, and solid polyethylene. An inhomogeneous dielectric needs to be compensated by a non-circular conductor to avoid current hot-spots.

While many cables have a solid dielectric, many others have a foam dielectric that contains as much air or other gas as possible to reduce the losses by allowing the use of a larger diameter center conductor. Foam coax will have about 15% less attenuation but some types of foam dielectric can absorb moisture—especially at its many surfaces—in humid environments, significantly increasing the loss. Supports shaped like stars or spokes are even better but more expensive and very susceptible to moisture infiltration. Still more expensive were the air-spaced coaxials used for some inter-city communications in the mid-20th century. The center conductor was suspended by polyethylene discs every few centimeters. In some low-loss coaxial cables such as the RG-62 type, the inner conductor is supported by a spiral strand of polyethylene, so that an air space exists between most of the conductor and the inside of the jacket. The lower dielectric constant of air allows for a greater inner diameter at the same impedance and a greater outer diameter at the same cutoff frequency, lowering ohmic losses. Inner conductors are sometimes silver-plated to smooth the surface and reduce losses due to skin effect.[4] A rough surface extends the current path and concentrates the current at peaks, thus increasing ohmic loss.

The insulating jacket can be made from many materials. A common choice is PVC, but some applications may require fire-resistant materials. Outdoor applications may require the jacket to resist ultraviolet light, oxidation, rodent damage, or direct burial. Flooded coaxial cables use a water-blocking gel to protect the cable from water infiltration through minor cuts in the jacket. For internal chassis connections the insulating jacket may be omitted.[examples needed]

Signal propagation

Twin-lead transmission lines have the property that the electromagnetic wave propagating down the line extends into the space surrounding the parallel wires. These lines have low loss, but also have undesirable characteristics. They cannot be bent, tightly twisted, or otherwise shaped without changing their characteristic impedance, causing reflection of the signal back toward the source. They also cannot be buried or run along or attached to anything conductive, as the extended fields will induce currents in the nearby conductors causing unwanted radiation and detuning of the line. Standoff insulators are used to keep them away from parallel metal surfaces. Coaxial lines largely solve this problem by confining virtually all of the electromagnetic wave to the area inside the cable. Coaxial lines can therefore be bent and moderately twisted without negative effects, and they can be strapped to conductive supports without inducing unwanted currents in them, so long as provisions are made to ensure differential signalling push-pull currents in the cable.

In radio-frequency applications up to a few gigahertz, the wave propagates primarily in the transverse electric magnetic (TEM) mode, which means that the electric and magnetic fields are both perpendicular to the direction of propagation. However, above a certain cutoff frequency, transverse electric (TE) or transverse magnetic (TM) modes can also propagate, as they do in a hollow waveguide. It is usually undesirable to transmit signals above the cutoff frequency, since it may cause multiple modes with different phase velocities to propagate, interfering with each other. The outer diameter is roughly inversely proportional to the cutoff frequency. A propagating surface-wave mode that only involves the central conductor also exists, but is effectively suppressed in coaxial cable of conventional geometry and common impedance. Electric field lines for this TM mode have a longitudinal component and require line lengths of a half-wavelength or longer.

Coaxial cable may be viewed as a type of waveguide. Power is transmitted through the radial electric field and the circumferential magnetic field in the TEM mode. This is the dominant mode from zero frequency (DC) to an upper limit determined by the electrical dimensions of the cable.[6]

Connectors

 
A male F-type connector used with common RG-6 cable
 
A male N-type connector

Coaxial connectors are designed to maintain a coaxial form across the connection and have the same impedance as the attached cable.[4] Connectors are usually plated with high-conductivity metals such as silver or tarnish-resistant gold. Due to the skin effect, the RF signal is only carried by the plating at higher frequencies and does not penetrate to the connector body. Silver however tarnishes quickly and the silver sulfide that is produced is poorly conductive, degrading connector performance, making silver a poor choice for this application.[7]

Important parameters

Coaxial cable is a particular kind of transmission line, so the circuit models developed for general transmission lines are appropriate. See Telegrapher's equation.

 
Schematic representation of the elementary components of a transmission line
 
Schematic representation of a coaxial transmission line, showing the characteristic impedance  

Physical parameters

In the following section, these symbols are used:

  • Length of the cable,  
  • Outside diameter of inner conductor,  
  • Inside diameter of the shield,  
  • Dielectric constant of the insulator,   The dielectric constant is often quoted as the relative dielectric constant   referred to the dielectric constant of free space     When the insulator is a mixture of different dielectric materials (e.g., polyethylene foam is a mixture of polyethylene and air), then the term effective dielectric constant   is often used.
  • Magnetic permeability of the insulator,   Permeability is often quoted as the relative permeability   referred to the permeability of free space     The relative permeability will almost always be 1.

Fundamental electrical parameters

 
 
  • Series resistance per unit length, in ohms per metre. The resistance per unit length is just the resistance of inner conductor and the shield at low frequencies. At higher frequencies, skin effect increases the effective resistance by confining the conduction to a thin layer of each conductor.
  • Shunt conductance per unit length, in siemens per metre. The shunt conductance is usually very small because insulators with good dielectric properties are used (a very low loss tangent). At high frequencies, a dielectric can have a significant resistive loss.

Derived electrical parameters

 
Where R is the resistance per unit length, L is the inductance per unit length, G is the conductance per unit length of the dielectric, C is the capacitance per unit length, and s = = j2πf is the frequency. The "per unit length" dimensions cancel out in the impedance formula.
At DC the two reactive terms are zero, so the impedance is real-valued, and is extremely high. It looks like
 
With increasing frequency, the reactive components take effect and the impedance of the line is complex-valued. At very low frequencies (audio range, of interest to telephone systems) G is typically much smaller than sC, so the impedance at low frequencies is
 
which has a phase value of -45 degrees.
At higher frequencies, the reactive terms usually dominate R and G, and the cable impedance again becomes real-valued. That value is Zo, the characteristic impedance of the cable:
 
Assuming the dielectric properties of the material inside the cable do not vary appreciably over the operating range of the cable, the characteristic impedance is frequency independent above about five times the shield cutoff frequency. For typical coaxial cables, the shield cutoff frequency is 600 Hz (for RG-6A) to 2,000 Hz (for RG-58C).[9]
The parameters L and C are determined from the ratio of the inner (d) and outer (D) diameters and the dielectric constant (ε). The characteristic impedance is given by[10]
 
  • Attenuation (loss) per unit length, in decibels per meter. This is dependent on the loss in the dielectric material filling the cable, and resistive losses in the center conductor and outer shield. These losses are frequency dependent, the losses becoming higher as the frequency increases. Skin effect losses in the conductors can be reduced by increasing the diameter of the cable. A cable with twice the diameter will have half the skin effect resistance. Ignoring dielectric and other losses, the larger cable would halve the dB/meter loss. In designing a system, engineers consider not only the loss in the cable but also the loss in the connectors.
  • Velocity of propagation, in meters per second. The velocity of propagation depends on the dielectric constant and permeability (which is usually 1).
 
  • Single-mode band. In coaxial cable, the dominant mode (the mode with the lowest cutoff frequency) is the TEM mode,[6] which has a cutoff frequency of zero; it propagates all the way down to DC. The mode with the next lowest cutoff is the TE11 mode. This mode has one 'wave' (two reversals of polarity) in going around the circumference of the cable. To a good approximation, the condition for the TE11 mode to propagate is that the wavelength in the dielectric is no longer than the average circumference of the insulator; that is that the frequency is at least
 
Hence, the cable is single-mode from DC up to this frequency, and might in practice be used up to 90%[11] of this frequency.
  • Peak Voltage. The peak voltage is set by the breakdown voltage of the insulator.:[12]
 
where
Vp is the peak voltge
Ed is the insulator's breakdown voltage in volts per meter
d is the inner diameter in meters
D is the outer diameter in meters
The calculated peak voltage is often reduced by a safety factor.

Choice of impedance

The best coaxial cable impedances were experimentally determined at Bell Laboratories in 1929 to be 77 Ω for low-attenuation, 60 Ω for high-voltage, and 30 Ω for high-power. For a coaxial cable with air dielectric and a shield of a given inner diameter, the attenuation is minimized by choosing the diameter of the inner conductor to give a characteristic impedance of 76.7 Ω.[13] When more common dielectrics are considered, the lowest insertion loss impedance drops down to a value between 52 and 64 Ω. Maximum power handling is achieved at 30 Ω.[14]

The approximate impedance required to match a centre-fed dipole antenna in free space (i.e., a dipole without ground reflections) is 73 Ω, so 75 Ω coax was commonly used for connecting shortwave antennas to receivers. These typically involve such low levels of RF power that power-handling and high-voltage breakdown characteristics are unimportant when compared to attenuation. Likewise with CATV, although many broadcast TV installations and CATV headends use 300 Ω folded dipole antennas to receive off-the-air signals, 75 Ω coax makes a convenient 4:1 balun transformer for these as well as possessing low attenuation.

The arithmetic mean between 30 Ω and 77 Ω is 53.5 Ω; the geometric mean is 48 Ω. The selection of 50 Ω as a compromise between power-handling capability and attenuation is in general cited as the reason for the number.[13] 50 Ω also works out tolerably well because it corresponds approximately to the feedpoint impedance of a half-wave dipole, mounted approximately a half-wave above "normal" ground (ideally 73 Ω, but reduced for low-hanging horizontal wires).

RG-62 is a 93 Ω coaxial cable originally used in mainframe computer networks in the 1970s and early 1980s (it was the cable used to connect IBM 3270 terminals to IBM 3274/3174 terminal cluster controllers). Later, some manufacturers of LAN equipment, such as Datapoint for ARCNET, adopted RG-62 as their coaxial cable standard. The cable has the lowest capacitance per unit-length when compared to other coaxial cables of similar size.

All of the components of a coaxial system should have the same impedance to avoid internal reflections at connections between components (see Impedance matching). Such reflections may cause signal attenuation. They introduce standing waves, which increase losses and can even result in cable dielectric breakdown with high-power transmission. In analog video or TV systems, reflections cause ghosting in the image; multiple reflections may cause the original signal to be followed by more than one echo. If a coaxial cable is open (not connected at the end), the termination has nearly infinite resistance, which causes reflections. If the coaxial cable is short-circuited, the termination resistance is nearly zero, which causes reflections with the opposite polarity. Reflections will be nearly eliminated if the coaxial cable is terminated in a pure resistance equal to its impedance.

Coaxial characteristic impedance derivation

Taking the characteristic impedance at high frequencies,

 

One should also know the inductance and capacitance of the two concentric cylindrical conductors which is the coaxial cable. By definition   and getting the electric field by the formula of electric field of an infinite line,

 

where   is charge,  is the permittivity of free space,   is the radial distance and   is the unit vector in the direction away from the axis. The voltage, V, is

 

where   is the inner diameter of the outer conductor and   is the diameter of the inner conductor. The capacitance can then be solved by substitution,

 

and the inductance is taken from Ampere's Law for two concentric conductors (coaxial wire) and with the definition of inductance,

  and  

where   is magnetic induction,   is the permeability of free space,   is the magnetic flux and   is the differential surface. Taking the inductance per meter,

 ,

Substituting the derived capacitance and inductance, and generalizing them to the case where a dielectric of permeability   and permittivity   is used in between the inner and outer conductors,

 [15]

Issues

Signal leakage

Signal leakage is the passage of electromagnetic fields through the shield of a cable and occurs in both directions. Ingress is the passage of an outside signal into the cable and can result in noise and disruption of the desired signal. Egress is the passage of signal intended to remain within the cable into the outside world and can result in a weaker signal at the end of the cable and radio frequency interference to nearby devices. Severe leakage usually results from improperly installed connectors or faults in the cable shield.

For example, in the United States, signal leakage from cable television systems is regulated by the FCC, since cable signals use the same frequencies as aeronautical and radionavigation bands. CATV operators may also choose to monitor their networks for leakage to prevent ingress. Outside signals entering the cable can cause unwanted noise and picture ghosting. Excessive noise can overwhelm the signal, making it useless. In-channel ingress can be digitally removed by ingress cancellation.

An ideal shield would be a perfect conductor with no holes, gaps, or bumps connected to a perfect ground. However, a smooth solid highly conductive shield would be heavy, inflexible, and expensive. Such coax is used for straight-line feeds to commercial radio broadcast towers. More economical cables must make compromises between shield efficacy, flexibility, and cost, such as the corrugated surface of flexible hardline, flexible braid, or foil shields. Since shields cannot be perfect conductors, current flowing on the inside of the shield produces an electromagnetic field on the outer surface of the shield.

Consider the skin effect. The magnitude of an alternating current in a conductor decays exponentially with distance beneath the surface, with the depth of penetration being proportional to the square root of the resistivity. This means that, in a shield of finite thickness, some small amount of current will still be flowing on the opposite surface of the conductor. With a perfect conductor (i.e., zero resistivity), all of the current would flow at the surface, with no penetration into and through the conductor. Real cables have a shield made of an imperfect, although usually very good, conductor, so there must always be some leakage.

The gaps or holes, allow some of the electromagnetic field to penetrate to the other side. For example, braided shields have many small gaps. The gaps are smaller when using a foil (solid metal) shield, but there is still a seam running the length of the cable. Foil becomes increasingly rigid with increasing thickness, so a thin foil layer is often surrounded by a layer of braided metal, which offers greater flexibility for a given cross-section.

Signal leakage can be severe if there is poor contact at the interface to connectors at either end of the cable or if there is a break in the shield.

To greatly reduce signal leakage into or out of the cable, by a factor of 1000, or even 10,000, superscreened cables are often used in critical applications, such as for neutron flux counters in nuclear reactors.

Superscreened cables for nuclear use are defined in IEC 96-4-1, 1990, however as there have been long gaps in the construction of nuclear power stations in Europe, many existing installations are using superscreened cables to the UK standard AESS(TRG) 71181[16] which is referenced in IEC 61917.[17]

Ground loops

A continuous current, even if small, along the imperfect shield of a coaxial cable can cause visible or audible interference. In CATV systems distributing analog signals the potential difference between the coaxial network and the electrical grounding system of a house can cause a visible "hum bar" in the picture. This appears as a wide horizontal distortion bar in the picture that scrolls slowly upward. Such differences in potential can be reduced by proper bonding to a common ground at the house. See ground loop.

Noise

External fields create a voltage across the inductance of the outside of the outer conductor between sender and receiver. The effect is less when there are several parallel cables, as this reduces the inductance and, therefore, the voltage. Because the outer conductor carries the reference potential for the signal on the inner conductor, the receiving circuit measures the wrong voltage.

Transformer effect

The transformer effect is sometimes used to mitigate the effect of currents induced in the shield. The inner and outer conductors form the primary and secondary winding of the transformer, and the effect is enhanced in some high-quality cables that have an outer layer of mu-metal. Because of this 1:1 transformer, the aforementioned voltage across the outer conductor is transformed onto the inner conductor so that the two voltages can be cancelled by the receiver. Many senders and receivers have means to reduce the leakage even further. They increase the transformer effect by passing the whole cable through a ferrite core one or more times.

Common mode current and radiation

Common mode current occurs when stray currents in the shield flow in the same direction as the current in the center conductor, causing the coax to radiate. They are the opposite of the desired "push-pull" differential signalling currents, where the signal currents on the inner and outer conductor are equal and opposite.

Most of the shield effect in coax results from opposing currents in the center conductor and shield creating opposite magnetic fields that cancel, and thus do not radiate. The same effect helps ladder line. However, ladder line is extremely sensitive to surrounding metal objects, which can enter the fields before they completely cancel. Coax does not have this problem, since the field is enclosed in the shield. However, it is still possible for a field to form between the shield and other connected objects, such as the antenna the coax feeds. The current formed by the field between the antenna and the coax shield would flow in the same direction as the current in the center conductor, and thus not be canceled. Energy would radiate from the coax itself, affecting the radiation pattern of the antenna. With sufficient power, this could be a hazard to people near the cable. A properly placed and properly sized balun can prevent common-mode radiation in coax. An isolating transformer or blocking capacitor can be used to couple a coaxial cable to equipment, where it is desirable to pass radio-frequency signals but to block direct current or low-frequency power.

Higher impedance at audio frequencies

The characteristic impedance formula above is a good approximation at radio frequencies however for frequencies below 100 kHz (such as audio) it becomes important to use the complete telegrapher's equation:

 

Applying this formula to typical 75 ohm coax we find the measured impedance across the audio spectrum will range from ~150 ohms to ~5K ohms, much higher than nominal. The velocity of propagation also slows considerably. Thus we can expect coax cable impedances to be consistent at RF frequencies but variable across audio frequencies. This effect was manifested when trying to send a plain voice signal across the transatlantic telegraph cable, with poor results.[18][19]

Standards

Most coaxial cables have a characteristic impedance of either 50, 52, 75, or 93 Ω. The RF industry uses standard type-names for coaxial cables. Thanks to television, RG-6 is the most commonly used coaxial cable for home use, and the majority of connections outside Europe are by F connectors.

A series of standard types of coaxial cable were specified for military uses, in the form "RG-#" or "RG-#/U". They date from World War II and were listed in MIL-HDBK-216 published in 1962. These designations are now obsolete. The RG designation stands for Radio Guide; the U designation stands for Universal. The current military standard is MIL-SPEC MIL-C-17. MIL-C-17 numbers, such as "M17/75-RG214", are given for military cables and manufacturer's catalog numbers for civilian applications. However, the RG-series designations were so common for generations that they are still used, although critical users should be aware that since the handbook is withdrawn there is no standard to guarantee the electrical and physical characteristics of a cable described as "RG-# type". The RG designators are mostly used to identify compatible connectors that fit the inner conductor, dielectric, and jacket dimensions of the old RG-series cables.

Type Impedance
(ohms)
Core (mm) Dielectric Outside diameter Shields Remarks Max. attenuation, 750 MHz
(dB/100 ft)
Type VF (in) (mm) (in) (mm)
RG-6/U 75 1.024 PF 0.75 0.185 4.7 0.270 6.86 Double Low loss at high frequency for cable television, satellite television and cable modems 5.65
RG-6/UQ 75 1.024 PF 0.75 0.185 4.7 0.298 7.57 Quad This is "quad shield RG-6". It has four layers of shielding; regular RG-6 has only one or two 5.65[20]
RG-7 75 1.30 PF 0.225 5.72 0.320 8.13 Double Low loss at high frequency for cable television, satellite television and cable modems 4.57
RG-8/U 50 2.17 PE 0.285 7.2 0.405 10.3 Amateur radio; Thicknet (10BASE5) is similar 5.97[21]
RG-8X 50 1.47 PF 0.82 0.155 3.9 0.242 6.1 Single A thinner version, with some of the electrical characteristics of RG-8U in a diameter similar to RG-59.[22] 10.95[21]
RG-9/U 51 PE 0.420 10.7
RG-11/U 75 1.63 PE 0.66–0.85 0.285 7.2 0.412 10.5 Dual/triple/quad Low loss at high frequency for cable and satellite television. Used for long drops and underground conduit, similar to RG7 but generally lower loss.[23][24] 3.65
RG-56/U 48 1.4859 0.308 7.82 Dual braid shielded Rated to 8000 volts, rubber dielectric
RG-58/U 50 0.81 PE 0.66 0.116 2.9 0.195 5.0 Single Used for radiocommunication and amateur radio, thin Ethernet (10BASE2) and NIM electronics, Loss 1.056 dB/m @ 2.4 GHz. Common.[25] 13.10[21]
RG-59/U 75 0.64 PE 0.66 0.146 3.7 0.242 6.1 Single Used to carry baseband video in closed-circuit television, previously used for cable television. In general, it has poor shielding but will carry an HQ HD signal or video over short distances.[26] 9.71[21]
RG-59A/U 75 0.762 PF 0.78 0.146 3.7 0.242 6.1 Single Similar physical characteristics as RG-59 and RG-59/U, but with a higher velocity factor. 8.9@700 MHz 8.9[27]
3C-2V 75 0.50 PE 0.85 3.0 5.4 Single Used to carry television, video observation systems, and other. PVC jacket.
5C-2V 75 0.80 PE 0.82±0.02 0.181 4.6 0.256 6.5 Double Used for interior lines for monitoring system, CCTV feeder lines, wiring between the camera and control unit and video signal transmission. PVC jacket.
RG-60/U 50 1.024 PE 0.425 10.8 Single Used for high-definition cable TV and high-speed cable Internet.
RG-62/U 92 PF 0.84 0.242 6.1 Single Used for ARCNET and automotive radio antennas.[28]
RG-62A 93 ASP 0.242 6.1 Single Used for NIM electronics
RG-63 125 1.2 PE 0.405 10.29 Double braid Used for aerospace 4.6
RG-142/U 50 0.94 PTFE 0.116 2.95 0.195 4.95 Double braid Used for test equipment 9.6
RG-174/U 50 0.5

(7×0.16)

PE 0.66 0.059 1.5 0.100 2.55 Single Common for Wi-Fi pigtails: more flexible but higher loss than RG58; used with LEMO 00 connectors in NIM electronics. 23.57[21]
RG-178/U 50 0.31

(7×0.1)

PTFE 0.69 0.033 0.84 0.071 1.8 Single Used for high-frequency signal transmission. 42.7 @ 900 MHz,[29] Core material: Ag-plated Cu-clad Steel 42.7[30]
RG-179/U 75 0.31

(7×0.1)

PTFE 0.67 0.063 1.6 0.098 2.5 Single VGA RGBHV,[31] Core material: Ag-plated Cu
RG-180B/U 95 0.31 PTFE 0.102 2.59 0.145 3.68 Single silver-covered copper VGA RGBHV, Core material: Ag-plated Cu-clad steel
RG-188A/U 50 0.5

(7×0.16)

PTFE 0.70 0.06 1.52 0.1 2.54 Single 26.2 @ 1000 MHz, Core material: Ag-plated Cu-clad steel 26.2[32]
RG-195 95 0.305 PTFE 0.102 2.59 0.145 3.68 Single PTFE jacket suitable for direct burial, Core material: Ag-plated Cu-clad steel [33]
RG-213/U 50 2.26

(7×0.75)

PE 0.66 0.285 7.2 0.405 10.3 Single For radiocommunication and amateur radio, EMC test antenna cables. Typically lower loss than RG58. Common.[34] 5.98[21]
RG-214/U 50 2.26

(7×0.75)

PE 0.66 0.285 7.2 0.425 10.8 Double Used for high-frequency signal transmission.[35] 6.7[21]
RG-218 50 4.963 PE 0.66 0.660 (0.680?) 16.76 (17.27?) 0.870 22 Single Large diameter, not very flexible, low-loss (2.5 dB/100 ft @ 400 MHz), 11 kV dielectric withstand. 2.83[21]
RG-223/U 50 0.88 PE 0.66 0.0815 2.07 0.212 5.4 Double Silver-plated shields. 11.46[21]
RG-316/U 50 0.51

(7×0.17)

PTFE 0.695 0.060 1.5 0.098 2.6 Single Used with LEMO 00 connectors in NIM electronics[36] 22.45[21]
RG-400/U 50 1.0

(19×0.20)

PTFE 2.95 4.95 Double [37] 12.57[21]
RG-402/U 50 0.93 PTFE 3.0 0.141 3.58 Single silver-plated copper Semi-rigid, 0.91 dB/m@5 GHz 27.7
RG-405/U 50 0.51 PTFE 1.68 0.0865 2.20 Single silver-plated copper-clad steel Semi-rigid, 1.51 dB/m@5 GHz 46.0
H155 50 1.41

(19×0.28)

PF 0.79 0.0984 2.5 0.2126 5.4 Double Lower loss at high frequency for radiocommunication and amateur radio
H500 50 2.5 PF 0.81 0.1772 4.5 0.386 9.8 Double Low loss at high frequency for radiocommunication and amateur radio, 4.45 @ 1000 MHz 4.45[38]
LMR-100 50 0.46 PE 0.66 0.0417 1.06 0.110 2.79 Double Low loss communications, 1.36 dB/meter @ 2.4 GHz 20.7[21]
LMR-195 50 0.94 PF 0.80 0.073 1.85 0.195 4.95 Double Low loss communications, 0.620 dB/meter @ 2.4 GHz 10.1[21]
LMR-200
HDF-200
CFD-200
50 1.12 PF 0.83 0.116 2.95 0.195 4.95 Double Low-loss communications, 0.554 dB/meter @ 2.4 GHz 9.0[21]
LMR-240
EMR-240
50 1.42 PF 0.84 0.150 3.81 0.240 6.1 Double Amateur radio, low-loss replacement for RG-8X[39] 6.9[21]
LMR-300 50 1.78 PF 0.82 0.190 4.83 0.300 7.62 Foil, Braid Low-loss communications 5.5[21]
LMR-400
HDF-400
CFD-400
EMR-400
50 2.74 PF 0.85 0.285 7.24 0.405 10.29 Double Low-loss communications, 0.223 dB/meter @ 2.4 GHz,[40] Core material: Cu-clad Al 3.5[21]
LMR-500 50 3.61 PF 0.86 0.370 9.4 0.500 12.7 Double Low-loss communications, Core material: Cu-clad Al 2.8[21]
LMR-600 50 4.47 PF 0.87 0.455 11.56 0.590 14.99 Double Low-loss communications, 0.144 dB/meter @ 2.4 GHz, Core material: Cu-clad Al 2.3[21]
LMR-900 50 6.65 PF 0.87 0.680 17.27 0.870 22.10 Double Low-loss communications, 0.098 dB/meter @ 2.4 GHz, Core material: BC tube 1.5[21]
LMR-1200 50 8.86 PF 0.88 0.920 23.37 1.200 30.48 Double Low-loss communications, 0.075 dB/meter @ 2.4 GHz, Core material: BC tube 1.3[21]
LMR-1700 50 13.39 PF 0.89 1.350 34.29 1.670 42.42 Double Low-loss communications, 0.056 dB/meter @ 2.4 GHz, Core material: BC tube 0.8[21]
LDF4-50A[5] 50 4.83 FPE 0.88 0.51 12.96 0.55 13.97 corrugated copper Heliax Cellflex low-loss semi-flexible 1.90
AVA5-50 50 9.45 FPE 0.88 0.95 24.1 1.000 25.4 corrugated copper Heliax Cellflex low-loss semi-flexible 0.98
AVA7-50 50 18.6 FPE 0.92 1.75 44.5 1.825 46.4 corrugated copper Heliax Cellflex low-loss semi-flexible 0.58
HCA214-50J 50 22.7 Air 0.95 1.96 49.9 2.37 60.2 corrugated copper Semi-flexible hardline 0.50
HCA300-50J 50 29.3 Air 0.96 2.50 63.5 2.99 76.0 corrugated copper Semi-flexible hardline 0.39
HCA400-50J 50 34.8 Air 0.96 2.96 75.3 3.56 90.5 corrugated copper Semi-flexible hardline 0.33
HCA495-50J 50 45.0 Air 0.97 3.86 98.1 4.53 115.1 corrugated copper Semi-flexible hardline 0.25
HCA550-50J 50 58.0 Air 0.96 5.00 127.1 5.79 147.1 corrugated copper Semi-flexible hardline 0.20
HCA618-50J 50 67.0 Air 0.97 5.78 147.0 6.65 169 corrugated copper Semi-flexible hardline 0.17
HCA800-50J 50 88.5 Air 0.97 7.67 195.0 8.78 223.0 corrugated copper Semi-flexible hardline 650 MHz max.
HCA900-50T 50 99.4 Air 0.98 8.53 216.7 9.75 247.7 corrugated aluminum Semi-flexible hardline 560 MHz max.
QR-320 75 1.80 PF 0.395 10.03 Single Low-loss line, which replaced RG-11 in most applications 3.34
QR-540 75 3.15 PF 0.610 15.49 Single Low-loss hard line 1.85
QR-715 75 4.22 PF 0.785 19.94 Single Low-loss hard line 1.49
QR-860 75 5.16 PF 0.960 24.38 Single Low-loss hard line 1.24
QR-1125 75 6.68 PF 1.225 31.12 Single Low-loss hard line 1.01
Type Impedance
(ohms)
Core (mm) Dielectric Outside diameter Shields Remarks Max. attenuation, 750 MHz
(dB/100 ft)
Type VF (in) (mm) (in) (mm)

Dielectric material codes

VF is the Velocity Factor; it is determined by the effective   and  [42]

  • VF for solid PE is about 0.66
  • VF for foam PE is about 0.78 to 0.88
  • VF for air is about 1.00
  • VF for solid PTFE is about 0.70
  • VF for foam PTFE is about 0.84

There are also other designation schemes for coaxial cables such as the URM, CT, BT, RA, PSF and WF series.

 
RG-6 coaxial cable
 
RG-142 coaxial cable
 
RG-405 semi-rigid coaxial cable
 
High-end coaxial audio cable (S/PDIF)

Uses

Short coaxial cables are commonly used to connect home video equipment, in ham radio setups, and in NIM. While formerly common for implementing computer networks, in particular Ethernet ("thick" 10BASE5 and "thin" 10BASE2), twisted pair cables have replaced them in most applications except in the growing consumer cable modem market for broadband Internet access.

Long distance coaxial cable was used in the 20th century to connect radio networks, television networks, and Long Distance telephone networks though this has largely been superseded by later methods (fibre optics, T1/E1, satellite).

Shorter coaxials still carry cable television signals to the majority of television receivers, and this purpose consumes the majority of coaxial cable production. In 1980s and early 1990s coaxial cable was also used in computer networking, most prominently in Ethernet networks, where it was later in late 1990s to early 2000s replaced by UTP cables in North America and STP cables in Western Europe, both with 8P8C modular connectors.

Micro coaxial cables are used in a range of consumer devices, military equipment, and also in ultra-sound scanning equipment.

The most common impedances that are widely used are 50 or 52 ohms, and 75 ohms, although other impedances are available for specific applications. The 50 / 52 ohm cables are widely used for industrial and commercial two-way radio frequency applications (including radio, and telecommunications), although 75 ohms is commonly used for broadcast television and radio.

Coax cable is often used to carry data/signals from an antenna to a receiver—from a satellite dish to a satellite receiver, from a television antenna to a television receiver, from a radio mast to a radio receiver, etc. In many cases, the same single coax cable carries power in the opposite direction, to the antenna, to power the low-noise amplifier. In some cases a single coax cable carries (unidirectional) power and bidirectional data/signals, as in DiSEqC.

Types

Hard line

 
1+58 in (41 mm) flexible line with (mostly) air dielectric
 
1+58 in (41 mm) Heliax coaxial cable with Cellflex FPE foamed polyethylene dielectric

Hard line is used in broadcasting as well as many other forms of radio communication. It is a coaxial cable constructed using round copper, silver or gold tubing or a combination of such metals as a shield. Some lower-quality hard line may use aluminum shielding. Aluminum, however, is easily oxidized and unlike silver oxide, aluminum oxide drastically loses effective conductivity. Therefore, all connections must be air and water tight. The center conductor may consist of solid copper, or copper-plated aluminum. Since skin effect is an issue with RF, copper plating provides sufficient surface for an effective conductor. Most varieties of hardline used for external chassis or when exposed to the elements have a PVC jacket; however, some internal applications may omit the insulation jacket. Hard line can be very thick, typically at least a half inch or 13 mm and up to several times that, and has low loss even at high power. These large-scale hard lines are almost always used in the connection between a transmitter on the ground and the antenna or aerial on a tower. Hard line may also be known by trademarked names such as Heliax (CommScope),[43] or Cablewave (RFS/Cablewave).[44] Larger varieties of hardline may have a center conductor that is constructed from either rigid or corrugated copper tubing. The dielectric in hard line may consist of polyethylene foam, air, or a pressurized gas such as nitrogen or desiccated air (dried air). In gas-charged lines, hard plastics such as nylon are used as spacers to separate the inner and outer conductors. The addition of these gases into the dielectric space reduces moisture contamination, provides a stable dielectric constant, and provides a reduced risk of internal arcing. Gas-filled hardlines are usually used on high-power RF transmitters such as television or radio broadcasting, military transmitters, and high-power amateur radio applications but may also be used on some critical lower-power applications such as those in the microwave bands. However, in the microwave region, waveguide is more often used than hard line for transmitter-to-antenna, or antenna-to-receiver applications. The various shields used in hard line also differ; some forms use rigid tubing, or pipe, while others may use a corrugated tubing, which makes bending easier, as well as reduces kinking when the cable is bent to conform. Smaller varieties of hard line may be used internally in some high-frequency applications, in particular in equipment within the microwave range, to reduce interference between stages of the device.

Radiating

Radiating or leaky cable is another form of coaxial cable which is constructed in a similar fashion to hard line, however it is constructed with tuned slots cut into the shield. These slots are tuned to the specific RF wavelength of operation or tuned to a specific radio frequency band. This type of cable is to provide a tuned bi-directional "desired" leakage effect between transmitter and receiver. It is often used in elevator shafts, US Navy Ships, underground transportation tunnels and in other areas where an antenna is not feasible. One example of this type of cable is Radiax (CommScope).[45]

RG-6

RG-6 is available in four different types designed for various applications. In addition, the core may be copper clad steel (CCS) or bare solid copper (BC). "Plain" or "house" RG-6 is designed for indoor or external house wiring. "Flooded" cable is infused with waterblocking gel for use in underground conduit or direct burial. "Messenger" may contain some waterproofing but is distinguished by the addition of a steel messenger wire along its length to carry the tension involved in an aerial drop from a utility pole. "Plenum" cabling is expensive and comes with a special Teflon-based outer jacket designed for use in ventilation ducts to meet fire codes. It was developed since the plastics used as the outer jacket and inner insulation in many "Plain" or "house" cabling gives off poisonous gas when burned.

Triaxial cable

Triaxial cable or triax is coaxial cable with a third layer of shielding, insulation and sheathing. The outer shield, which is earthed (grounded), protects the inner shield from electromagnetic interference from outside sources.

Twin-axial cable

Twin-axial cable or twinax is a balanced, twisted pair within a cylindrical shield. It allows a nearly perfect differential signalling which is both shielded and balanced to pass through. Multi-conductor coaxial cable is also sometimes used.

Semi-rigid

 
Semi-rigid coax assembly
 
Semi-rigid coax installed in an Agilent N9344C 20GHz spectrum analyser

Semi-rigid cable is a coaxial form using a solid copper outer sheath. This type of coax offers superior screening compared to cables with a braided outer conductor, especially at higher frequencies. The major disadvantage is that the cable, as its name implies, is not very flexible, and is not intended to be flexed after initial forming. (See § Hard line)

Conformable cable is a flexible reformable alternative to semi-rigid coaxial cable used where flexibility is required. Conformable cable can be stripped and formed by hand without the need for specialized tools, similar to standard coaxial cable.

Rigid line

Rigid line is a coaxial line formed by two copper tubes maintained concentric every other meter using PTFE-supports. Rigid lines cannot be bent, so they often need elbows. Interconnection with rigid line is done with an inner bullet/inner support and a flange or connection kit. Typically, rigid lines are connected using standardised EIA RF Connectors whose bullet and flange sizes match the standard line diameters. For each outer diameter, either 75 or 50 ohm inner tubes can be obtained. Rigid line is commonly used indoors for interconnection between high-power transmitters and other RF-components, but more rugged rigid line with weatherproof flanges is used outdoors on antenna masts, etc. In the interests of saving weight and costs, on masts and similar structures the outer line is often aluminium, and special care must be taken to prevent corrosion. With a flange connector, it is also possible to go from rigid line to hard line. Many broadcasting antennas and antenna splitters use the flanged rigid line interface even when connecting to flexible coaxial cables and hard line. Rigid line is produced in a number of different sizes:

Size Outer conductor Inner conductor
Outer diameter (not flanged) Inner diameter Outer diameter Inner diameter
7/8" 22.2 mm 20 mm 8.7 mm 7.4 mm
1 5/8" 41.3 mm 38.8 mm 16.9 mm 15.0 mm
3 1/8" 79.4 mm 76.9 mm 33.4 mm 31.3 mm
4 1/2" 106 mm 103 mm 44.8 mm 42.8 mm
6 1/8" 155.6 mm 151.9 mm 66.0 mm 64.0 mm

Cables used in the UK

At the start of analog satellite TV broadcasts in the UK by Sky, a 75 ohm cable referred to as RG6 was used. This cable had a 1 mm copper core, air-spaced polyethylene dielectric and copper braid on an aluminum foil shield. When installed outdoors without protection, the cable was affected by UV radiation, which cracked the PVC outer sheath and allowed moisture ingress. The combination of copper, aluminum, moisture and air caused rapid corrosion, sometimes resulting in a 'snake swallowed an egg' appearance. Consequently, despite the higher cost, the RG6 cable was dropped in favor of CT100 when Sky launched its digital broadcasts.

From around 1999 to 2005 (when CT100 manufacturer Raydex went out of business), CT100 remained the 75 ohm cable of choice for satellite TV and especially Sky. It had an air-spaced polyethylene dielectric, a 1 mm solid copper core and copper braid on copper foil shield. CT63 was a thinner cable in 'shotgun' style, meaning that it was two cables molded together and was used mainly by Sky for the twin connection required by the Sky+ satellite TV receiver, which incorporated a hard drive recording system and a second, independent tuner.

In 2005, these cables were replaced by WF100 and WF65, respectively, manufactured by Webro and having a similar construction but a foam dielectric that provided the same electrical performance as air-spaced but was more robust and less likely to be crushed.

At the same time, with the price of copper steadily rising, the original RG6 was dropped in favor of a construction that used a copper-clad steel core and aluminum braid on aluminum foil. Its lower price made it attractive to aerial installers looking for a replacement for the so-called low-loss cable traditionally used for UK terrestrial aerial installations. This cable had been manufactured with a decreasing number of strands of braid, as the price of copper increased, such that the shielding performance of cheaper brands had fallen to as low as 40 percent. With the advent of digital terrestrial transmissions in the UK, this low-loss cable was no longer suitable.

The new RG6 still performed well at high frequencies because of the skin effect in the copper cladding. However, the aluminum shield had a high DC resistance and the steel core an even higher one. The result is that this type of cable could not reliably be used in satellite TV installations, where it was required to carry a significant amount of current, because the voltage drop affected the operation of the low noise block downconverter (LNB) on the dish.

A problem with all the aforementioned cables, when passing current, is that electrolytic corrosion can occur in the connections unless moisture and air are excluded. Consequently, various solutions to exclude moisture have been proposed. The first was to seal the connection by wrapping it with self-amalgamating rubberized tape, which bonds to itself when activated by stretching. The second proposal, by the American Channel Master company (now owned by Andrews corp.) at least as early as 1999, was to apply silicone grease to the wires making connection. The third proposal was to fit a self-sealing plug to the cable. All of these methods are reasonably successful if implemented correctly.

Interference and troubleshooting

Coaxial cable insulation may degrade, requiring replacement of the cable, especially if it has been exposed to the elements on a continuous basis. The shield is normally grounded, and if even a single thread of the braid or filament of foil touches the center conductor, the signal will be shorted causing significant or total signal loss. This most often occurs at improperly installed end connectors and splices. Also, the connector or splice must be properly attached to the shield, as this provides the path to ground for the interfering signal.

Despite being shielded, interference can occur on coaxial cable lines. Susceptibility to interference has little relationship to broad cable type designations (e.g. RG-59, RG-6) but is strongly related to the composition and configuration of the cable's shielding. For cable television, with frequencies extending well into the UHF range, a foil shield is normally provided, and will provide total coverage as well as high effectiveness against high-frequency interference. Foil shielding is ordinarily accompanied by a tinned copper or aluminum braid shield, with anywhere from 60 to 95% coverage. The braid is important to shield effectiveness because (1) it is more effective than foil at preventing low-frequency interference, (2) it provides higher conductivity to ground than foil, and (3) it makes attaching a connector easier and more reliable. "Quad-shield" cable, using two low-coverage aluminum braid shields and two layers of foil, is often used in situations involving troublesome interference, but is less effective than a single layer of foil and single high-coverage copper braid shield such as is found on broadcast-quality precision video cable.

In the United States and some other countries, cable television distribution systems use extensive networks of outdoor coaxial cable, often with in-line distribution amplifiers. Leakage of signals into and out of cable TV systems can cause interference to cable subscribers and to over-the-air radio services using the same frequencies as those of the cable system.

History

 
Early coaxial antenna feedline of 50 kW radio station WNBC, New York, 1930s
 
AT&T coaxial cable trunkline installed between East Coast and Midwest in 1948. Each of the 8 coaxial subcables could carry 480 telephone calls or one television channel.

See also

References

  1. ^ Nahin, Paul J. (2002). Oliver Heaviside: The Life, Work, and Times of an Electrical Genius of the Victorian Age. ISBN 0-8018-6909-9.
  2. ^ a b Silver, H. Ward N0AX; Wilson, Mark J. K1RO, eds. (2010). "Chapter 20: Transmission Lines". The ARRL Handbook for Radio Communications (87th ed.). The American Radio Relay League. ISBN 978-0-87259-144-8.
  3. ^ van der Burgt, Martin J. (PDF). Belden. p. 4. Archived from the original (PDF) on 28 July 2011. Retrieved 11 July 2011.
  4. ^ a b c d e "5: Transmission Media". The ARRL UHF/Microwave Experimenter's Manual. Newington, CT: American Radio Relay League. 1990. pp. 5.19–5.21. ISBN 0872593126.
  5. ^ a b (PDF). Archived from the original (PDF) on 2017-07-13. Retrieved May 25, 2017.
  6. ^ a b Jackson, John David (1962). Classical Electrodynamics (PDF). New York: John Wiley & Sons, Inc. p. 244. (PDF) from the original on 2021-10-27.
  7. ^ "White Bronze, Copper-Tin-Zinc Tri-metal: Expanding Applications and New Developments in a Changing Landscape" (PDF). National Association for Surface Finishing. June 2013. (PDF) from the original on 2022-03-06.
  8. ^ Pozar, David M. (1993). Microwave Engineering. Addison-Wesley Publishing Company. ISBN 0201504189.
  9. ^ Ott, Henry W. (1976). Noise Reduction Techniques in Electronic Systems. ISBN 0-471-65726-3.
  10. ^ Elmore, William C.; Heald, Mark A. (1985). Physics of Waves. ISBN 0-486-64926-1.
  11. ^ Kizer, George Maurice (1990). Microwave communication. Iowa State University Press. p. 312. ISBN 978-0-8138-0026-4.
  12. ^ . Archived from the original on 14 July 2014.
  13. ^ a b . Microwaves 101. 13 January 2009. Archived from the original on 14 July 2014.
  14. ^ . Microwaves 101. 14 September 2008. Archived from the original on 28 January 2012.
  15. ^ . RF Cafe. Archived from the original on 2012-01-19. Retrieved 2012-01-25.
  16. ^ "AESS(TRG) 71181 Part 2, May 1977 Superscreened co-axial cables for the nuclear power industry". May 1977. {{cite journal}}: Cite journal requires |journal= (help)
  17. ^ "IEC 61917 Cables, cable assemblies and connectors – Introduction to electromagnetic (EMC) screening measurements First edition 1998-06" (PDF).[permanent dead link]
  18. ^ Silver, H. Ward; Ford, Steven R.; Wilson, Mark J., eds. (2015). "23.1.2". ARRL Antenna Book for Radio Communications (23rd ed.). Netwon, CT: ARRL. ISBN 978-1-62595-044-4.
  19. ^ Brown, Jim (2008). "Transmission Lines at Audio Frequencies, and a Bit of History" (PDF). The Audio Systems Group, Inc. Retrieved 2023-01-16.
  20. ^ . madaboutcable.com. Archived from the original on 2010-08-13. Retrieved 2011-06-28.
  21. ^ a b c d e f g h i j k l m n o p q r s t u v "Times Microwave Coax Loss Calculator". Retrieved 2011-10-26.
  22. ^ http://www.dxengineering.com/pdf/Belden%20RG8X%20Date%209258.pdf[bare URL PDF]
  23. ^ . madaboutcable.com. Archived from the original on 2010-08-11. Retrieved 2011-03-29.
  24. ^ (PDF). belden.com. Archived from the original (PDF) on 2018-02-24. Retrieved 2018-02-23.
  25. ^ . madaboutcable.com. Archived from the original on 2010-08-09. Retrieved 2011-03-29.
  26. ^ . madaboutcable.com. Archived from the original on 2010-08-11. Retrieved 2011-03-29.
  27. ^ "Cable Velocity Factor and Loss Data". febo.com.
  28. ^ . madaboutcable.com. Archived from the original on 2010-08-11. Retrieved 2011-03-29.
  29. ^ . madaboutcable.com. Archived from the original on 2011-09-28. Retrieved 2011-04-11.
  30. ^ "RG178 Mini-Coax".
  31. ^ . madaboutcable.com. Archived from the original on 2012-03-30. Retrieved 2011-06-28.
  32. ^ http://www.wellshow.com/spec/cable/Harbour-RG188.pdf[bare URL PDF]
  33. ^ . Archived from the original on 2021-08-17. Retrieved 2021-08-17.
  34. ^ . madaboutcable.com. Archived from the original on 2011-09-26. Retrieved 2011-06-28.
  35. ^ . madaboutcable.com. Archived from the original on 2010-10-08. Retrieved 2011-03-29.
  36. ^ . madaboutcable.com. Archived from the original on 2010-08-11. Retrieved 2011-06-28.
  37. ^ . madaboutcable.com. Archived from the original on 2011-09-28. Retrieved 2011-06-28.
  38. ^ http://www.dnd.hu/uploads/termek_doc/Belden_h500pe_en.pdf[bare URL PDF]
  39. ^ (PDF). Archived from the original (PDF) on 2011-10-18. Retrieved 2011-10-26.
  40. ^ . Archived from the original on 2008-12-07. Retrieved 2009-02-06.
  41. ^ . RF Cafe. Archived from the original on 2012-01-03. Retrieved 2012-01-25.
  42. ^ . Microwaves 101. 2010-03-30. Archived from the original on 2012-01-14. Retrieved 2012-01-25.
  43. ^ . Archived from the original on 2016-06-28. Retrieved 2016-06-28.
  44. ^ . Archived from the original on 2007-12-02. Retrieved 2007-12-04.
  45. ^ . Archived from the original on 2016-05-30. Retrieved 2016-06-28.
  46. ^ "Coaxial cable used in first Transatlantic telegraph cable". Harper's Weekly (38): 447–448. May 12, 1894. ISBN 9780801869099.
  47. ^ Nahin, Paul J. (13 November 2002). "3: The First Theory of the Electric Telegraph". Oliver Heaviside. ISBN 9780801869099.
  48. ^ Feldenkirchen, Wilfried (1994). Werner von Siemens - Inventor and International Entrepreneur. ISBN 0-8142-0658-1.
  49. ^ U.S. Patent 1,835,031
  50. ^ . earlytelevision.org. Archived from the original on 2007-12-03.
  51. ^ Huurdeman, Anton A. (31 July 2003). "Copper-Line Transmission". The worldwide history of telecommunications. ISBN 9780471205050.
  52. ^ . Time. December 14, 1936. Archived from the original on 2007-10-13.
  53. ^ "Gallery: An illustrated history of the transoceanic cable". Boing Boing.
  54. ^ Tozer, Edwin Paul J. (2004). Broadcast engineer's reference book. ISBN 9780240519081.
  55. ^ "Coaxial feeder or RF coax cable". Radio-electronics.com.
  56. ^ Teachout, Terry. "The New-Media Crisis of 1949". Wall Street Journal. Retrieved 19 January 2015.
  57. ^ "1956 TAT-1 Silver Commemorative Dish". Atlantic-cable.com.
  58. ^ Huurdeman, Anton A. (31 July 2003). The worldwide history of telecommunications. ISBN 9780471205050.
  59. ^ . National Archives of Australia. Archived from the original on 4 August 2017. Retrieved 14 September 2013.
  60. ^ The Australasian Engineer. 1962. p. 33.

External links

  • RF Transmission Lines and Fittings. Military Standardization Handbook MIL-HDBK-216, U.S. Department of Defense, 4 January 1962.
  • Cables, Radio Frequency, Flexible and Rigid Details Specification MIL-DTL-17H, 19 August 2005 (superseding MIL-C-17G, 9 March 1990).
  • "The Electromagnetic Theory of Coaxial Transmission Lines and Cylindrical Shields". Bell System Technical Journal. 13 (4). October 1934.
  • Brooke Clarke, "Transmission Line Zo vs. Frequency"


coaxial, cable, coax, redirects, here, coaxing, persuasion, coax, pronounced, type, electrical, cable, consisting, inner, conductor, surrounded, concentric, conducting, shield, with, separated, dielectric, insulating, material, many, coaxial, cables, also, hav. Coax redirects here For the act of coaxing see Persuasion Coaxial cable or coax pronounced ˈ k oʊ ae k s is a type of electrical cable consisting of an inner conductor surrounded by a concentric conducting shield with the two separated by a dielectric insulating material many coaxial cables also have a protective outer sheath or jacket The term coaxial refers to the inner conductor and the outer shield sharing a geometric axis RG 59 flexible coaxial cable composed of Outer plastic sheathWoven copper shieldInner dielectric insulatorCopper core Coaxial cable is a type of transmission line used to carry high frequency electrical signals with low losses It is used in such applications as telephone trunk lines broadband internet networking cables high speed computer data busses cable television signals and connecting radio transmitters and receivers to their antennas It differs from other shielded cables because the dimensions of the cable and connectors are controlled to give a precise constant conductor spacing which is needed for it to function efficiently as a transmission line In his 1880 British patent Oliver Heaviside showed how coaxial cable could eliminate signal interference between parallel cables Coaxial cable was used in the first 1858 and following transatlantic cable installations but its theory was not described until 1880 by English physicist engineer and mathematician Oliver Heaviside who patented the design in that year British patent No 1 407 1 Contents 1 Applications 2 Description 3 Construction 4 Signal propagation 5 Connectors 6 Important parameters 6 1 Physical parameters 6 2 Fundamental electrical parameters 6 3 Derived electrical parameters 6 4 Choice of impedance 7 Coaxial characteristic impedance derivation 8 Issues 8 1 Signal leakage 8 2 Ground loops 8 3 Noise 8 3 1 Transformer effect 8 4 Common mode current and radiation 8 5 Higher impedance at audio frequencies 9 Standards 10 Uses 11 Types 11 1 Hard line 11 2 Radiating 11 3 RG 6 11 4 Triaxial cable 11 5 Twin axial cable 11 6 Semi rigid 11 7 Rigid line 11 8 Cables used in the UK 12 Interference and troubleshooting 13 History 14 See also 15 References 16 External linksApplications EditCoaxial cable is used as a transmission line for radio frequency signals Its applications include feedlines connecting radio transmitters and receivers to their antennas computer network e g Ethernet connections digital audio S PDIF and distribution of cable television signals One advantage of coaxial over other types of radio transmission line is that in an ideal coaxial cable the electromagnetic field carrying the signal exists only in the space between the inner and outer conductors This allows coaxial cable runs to be installed next to metal objects such as gutters without the power losses that occur in other types of transmission lines Coaxial cable also provides protection of the signal from external electromagnetic interference Description Edit Coaxial cable cutaway not to scale Coaxial cable conducts electrical signal using an inner conductor usually a solid copper stranded copper or copper plated steel wire surrounded by an insulating layer and all enclosed by a shield typically one to four layers of woven metallic braid and metallic tape The cable is protected by an outer insulating jacket Normally the outside of the shield is kept at ground potential and a signal carrying voltage is applied to the center conductor When using differential signaling coaxial cable provides an advantage of equal push pull currents on the inner conductor and inside of the outer conductor that restrict the signal s electric and magnetic fields to the dielectric with little leakage outside the shield citation needed Further electric and magnetic fields outside the cable are largely kept from interfering with signals inside the cable if unequal currents are filtered out at the receiving end of the line This property makes coaxial cable a good choice both for carrying weak signals that cannot tolerate interference from the environment and for stronger electrical signals that must not be allowed to radiate or couple into adjacent structures or circuits 2 Larger diameter cables and cables with multiple shields have less leakage Common applications of coaxial cable include video and CATV distribution RF and microwave transmission and computer and instrumentation data connections 3 The characteristic impedance of the cable Z0 is determined by the dielectric constant of the inner insulator and the radii of the inner and outer conductors In radio frequency systems where the cable length is comparable to the wavelength of the signals transmitted a uniform cable characteristic impedance is important to minimize loss The source and load impedances are chosen to match the impedance of the cable to ensure maximum power transfer and minimum standing wave ratio Other important properties of coaxial cable include attenuation as a function of frequency voltage handling capability and shield quality 2 Construction EditCoaxial cable design choices affect physical size frequency performance attenuation power handling capabilities flexibility strength and cost The inner conductor might be solid or stranded stranded is more flexible To get better high frequency performance the inner conductor may be silver plated Copper plated steel wire is often used as an inner conductor for cable used in the cable TV industry 4 The insulator surrounding the inner conductor may be solid plastic a foam plastic or air with spacers supporting the inner wire The properties of the dielectric insulator determine some of the electrical properties of the cable A common choice is a solid polyethylene PE insulator used in lower loss cables Solid Teflon PTFE is also used as an insulator and exclusively in plenum rated cables citation needed Some coaxial lines use air or some other gas and have spacers to keep the inner conductor from touching the shield Many conventional coaxial cables use braided copper wire forming the shield This allows the cable to be flexible but it also means there are gaps in the shield layer and the inner dimension of the shield varies slightly because the braid cannot be flat Sometimes the braid is silver plated For better shield performance some cables have a double layer shield 4 The shield might be just two braids but it is more common now to have a thin foil shield covered by a wire braid Some cables may invest in more than two shield layers such as quad shield which uses four alternating layers of foil and braid Other shield designs sacrifice flexibility for better performance some shields are a solid metal tube Those cables cannot be bent sharply as the shield will kink causing losses in the cable When a foil shield is used a small wire conductor incorporated into the foil makes soldering the shield termination easier examples needed For high power radio frequency transmission up to about 1 GHz coaxial cable with a solid copper outer conductor is available in sizes of 0 25 inch upward The outer conductor is corrugated like a bellows to permit flexibility and the inner conductor is held in position by a plastic spiral to approximate an air dielectric 4 One brand name for such cable is Heliax 5 Coaxial cables require an internal structure of an insulating dielectric material to maintain the spacing between the center conductor and shield The dielectric losses increase in this order Ideal dielectric no loss vacuum air polytetrafluoroethylene PTFE polyethylene foam and solid polyethylene An inhomogeneous dielectric needs to be compensated by a non circular conductor to avoid current hot spots While many cables have a solid dielectric many others have a foam dielectric that contains as much air or other gas as possible to reduce the losses by allowing the use of a larger diameter center conductor Foam coax will have about 15 less attenuation but some types of foam dielectric can absorb moisture especially at its many surfaces in humid environments significantly increasing the loss Supports shaped like stars or spokes are even better but more expensive and very susceptible to moisture infiltration Still more expensive were the air spaced coaxials used for some inter city communications in the mid 20th century The center conductor was suspended by polyethylene discs every few centimeters In some low loss coaxial cables such as the RG 62 type the inner conductor is supported by a spiral strand of polyethylene so that an air space exists between most of the conductor and the inside of the jacket The lower dielectric constant of air allows for a greater inner diameter at the same impedance and a greater outer diameter at the same cutoff frequency lowering ohmic losses Inner conductors are sometimes silver plated to smooth the surface and reduce losses due to skin effect 4 A rough surface extends the current path and concentrates the current at peaks thus increasing ohmic loss The insulating jacket can be made from many materials A common choice is PVC but some applications may require fire resistant materials Outdoor applications may require the jacket to resist ultraviolet light oxidation rodent damage or direct burial Flooded coaxial cables use a water blocking gel to protect the cable from water infiltration through minor cuts in the jacket For internal chassis connections the insulating jacket may be omitted examples needed Signal propagation EditThis section needs additional citations for verification Please help improve this article by adding citations to reliable sources in this section Unsourced material may be challenged and removed March 2016 Learn how and when to remove this template message Twin lead transmission lines have the property that the electromagnetic wave propagating down the line extends into the space surrounding the parallel wires These lines have low loss but also have undesirable characteristics They cannot be bent tightly twisted or otherwise shaped without changing their characteristic impedance causing reflection of the signal back toward the source They also cannot be buried or run along or attached to anything conductive as the extended fields will induce currents in the nearby conductors causing unwanted radiation and detuning of the line Standoff insulators are used to keep them away from parallel metal surfaces Coaxial lines largely solve this problem by confining virtually all of the electromagnetic wave to the area inside the cable Coaxial lines can therefore be bent and moderately twisted without negative effects and they can be strapped to conductive supports without inducing unwanted currents in them so long as provisions are made to ensure differential signalling push pull currents in the cable In radio frequency applications up to a few gigahertz the wave propagates primarily in the transverse electric magnetic TEM mode which means that the electric and magnetic fields are both perpendicular to the direction of propagation However above a certain cutoff frequency transverse electric TE or transverse magnetic TM modes can also propagate as they do in a hollow waveguide It is usually undesirable to transmit signals above the cutoff frequency since it may cause multiple modes with different phase velocities to propagate interfering with each other The outer diameter is roughly inversely proportional to the cutoff frequency A propagating surface wave mode that only involves the central conductor also exists but is effectively suppressed in coaxial cable of conventional geometry and common impedance Electric field lines for this TM mode have a longitudinal component and require line lengths of a half wavelength or longer Coaxial cable may be viewed as a type of waveguide Power is transmitted through the radial electric field and the circumferential magnetic field in the TEM mode This is the dominant mode from zero frequency DC to an upper limit determined by the electrical dimensions of the cable 6 Connectors EditMain article RF connector A male F type connector used with common RG 6 cable A male N type connector Coaxial connectors are designed to maintain a coaxial form across the connection and have the same impedance as the attached cable 4 Connectors are usually plated with high conductivity metals such as silver or tarnish resistant gold Due to the skin effect the RF signal is only carried by the plating at higher frequencies and does not penetrate to the connector body Silver however tarnishes quickly and the silver sulfide that is produced is poorly conductive degrading connector performance making silver a poor choice for this application 7 Important parameters EditCoaxial cable is a particular kind of transmission line so the circuit models developed for general transmission lines are appropriate See Telegrapher s equation Schematic representation of the elementary components of a transmission line Schematic representation of a coaxial transmission line showing the characteristic impedance Z 0 displaystyle Z 0 Physical parameters Edit In the following section these symbols are used Length of the cable ℓ displaystyle ell Outside diameter of inner conductor d displaystyle d Inside diameter of the shield D displaystyle D Dielectric constant of the insulator ϵ displaystyle epsilon The dielectric constant is often quoted as the relative dielectric constant ϵ r displaystyle epsilon mathsf r referred to the dielectric constant of free space ϵ o displaystyle epsilon mathsf o ϵ ϵ r ϵ o displaystyle epsilon epsilon mathsf r epsilon mathsf o When the insulator is a mixture of different dielectric materials e g polyethylene foam is a mixture of polyethylene and air then the term effective dielectric constant ϵ e f f displaystyle epsilon mathsf eff is often used Magnetic permeability of the insulator m displaystyle mu Permeability is often quoted as the relative permeability m r displaystyle mu mathsf r referred to the permeability of free space m o displaystyle mu mathsf o m m r m o displaystyle mu mu mathsf r mu mathsf o The relative permeability will almost always be 1 Fundamental electrical parameters Edit Shunt capacitance per unit length in farads per metre 8 C ℓ 2 p ϵ ln D d 2 p ϵ o ϵ r ln D d displaystyle frac C ell frac 2 pi epsilon ln left frac D d right frac 2 pi epsilon mathsf o epsilon mathsf r ln left frac D d right dd Series inductance per unit length in henrys per metre L ℓ m 2 p ln D d m o m r 2 p ln D d displaystyle frac L ell frac mu 2 pi ln left frac D d right frac mu mathsf o mu mathsf r 2 pi ln left frac D d right dd Series resistance per unit length in ohms per metre The resistance per unit length is just the resistance of inner conductor and the shield at low frequencies At higher frequencies skin effect increases the effective resistance by confining the conduction to a thin layer of each conductor Shunt conductance per unit length in siemens per metre The shunt conductance is usually very small because insulators with good dielectric properties are used a very low loss tangent At high frequencies a dielectric can have a significant resistive loss Derived electrical parameters Edit Characteristic impedance in ohms W The complex impedance Z o of an infinite length of transmission line is Z o R s L G s C displaystyle Z mathsf o sqrt frac R sL G sC dd Where R is the resistance per unit length L is the inductance per unit length G is the conductance per unit length of the dielectric C is the capacitance per unit length and s jw j2pf is the frequency The per unit length dimensions cancel out in the impedance formula At DC the two reactive terms are zero so the impedance is real valued and is extremely high It looks likeZ D C R G displaystyle Z mathsf DC sqrt frac R G dd With increasing frequency the reactive components take effect and the impedance of the line is complex valued At very low frequencies audio range of interest to telephone systems G is typically much smaller than sC so the impedance at low frequencies isZ L o w F r e q R s C displaystyle Z mathsf LowFreq approx sqrt frac R sC dd which has a phase value of 45 degrees At higher frequencies the reactive terms usually dominate R and G and the cable impedance again becomes real valued That value is Zo the characteristic impedance of the cable Z o s L s C L C displaystyle Z mathsf o sqrt frac sL sC sqrt frac L C dd Assuming the dielectric properties of the material inside the cable do not vary appreciably over the operating range of the cable the characteristic impedance is frequency independent above about five times the shield cutoff frequency For typical coaxial cables the shield cutoff frequency is 600 Hz for RG 6A to 2 000 Hz for RG 58C 9 The parameters L and C are determined from the ratio of the inner d and outer D diameters and the dielectric constant e The characteristic impedance is given by 10 Z o 1 2 p m ϵ ln D d 59 96 W ϵ r ln D d 138 W ϵ r log 10 D d displaystyle Z mathsf o frac 1 2 pi sqrt frac mu epsilon ln left frac D d right approx frac 59 96 mathsf Omega sqrt epsilon mathsf r ln left frac D d right approx frac 138 mathsf Omega sqrt epsilon mathsf r log 10 left frac D d right dd Attenuation loss per unit length in decibels per meter This is dependent on the loss in the dielectric material filling the cable and resistive losses in the center conductor and outer shield These losses are frequency dependent the losses becoming higher as the frequency increases Skin effect losses in the conductors can be reduced by increasing the diameter of the cable A cable with twice the diameter will have half the skin effect resistance Ignoring dielectric and other losses the larger cable would halve the dB meter loss In designing a system engineers consider not only the loss in the cable but also the loss in the connectors Velocity of propagation in meters per second The velocity of propagation depends on the dielectric constant and permeability which is usually 1 v 1 ϵ m c ϵ r m r displaystyle v frac 1 sqrt epsilon mu frac c sqrt epsilon mathsf r mu mathsf r dd Single mode band In coaxial cable the dominant mode the mode with the lowest cutoff frequency is the TEM mode 6 which has a cutoff frequency of zero it propagates all the way down to DC The mode with the next lowest cutoff is the TE11 mode This mode has one wave two reversals of polarity in going around the circumference of the cable To a good approximation the condition for the TE11 mode to propagate is that the wavelength in the dielectric is no longer than the average circumference of the insulator that is that the frequency is at leastf c 1 p D d 2 m ϵ c p D d 2 m r ϵ r displaystyle f mathsf c approx frac 1 pi left frac D d 2 right sqrt mu epsilon frac c pi left frac D d 2 right sqrt mu mathsf r epsilon mathsf r dd Hence the cable is single mode from DC up to this frequency and might in practice be used up to 90 11 of this frequency Peak Voltage The peak voltage is set by the breakdown voltage of the insulator 12 V p E d d 2 ln D d displaystyle V mathsf p E mathsf d frac d 2 ln left frac D d right whereV p is the peak voltge E d is the insulator s breakdown voltage in volts per meter d is the inner diameter in meters D is the outer diameter in meters dd dd The calculated peak voltage is often reduced by a safety factor Choice of impedance Edit The best coaxial cable impedances were experimentally determined at Bell Laboratories in 1929 to be 77 W for low attenuation 60 W for high voltage and 30 W for high power For a coaxial cable with air dielectric and a shield of a given inner diameter the attenuation is minimized by choosing the diameter of the inner conductor to give a characteristic impedance of 76 7 W 13 When more common dielectrics are considered the lowest insertion loss impedance drops down to a value between 52 and 64 W Maximum power handling is achieved at 30 W 14 The approximate impedance required to match a centre fed dipole antenna in free space i e a dipole without ground reflections is 73 W so 75 W coax was commonly used for connecting shortwave antennas to receivers These typically involve such low levels of RF power that power handling and high voltage breakdown characteristics are unimportant when compared to attenuation Likewise with CATV although many broadcast TV installations and CATV headends use 300 W folded dipole antennas to receive off the air signals 75 W coax makes a convenient 4 1 balun transformer for these as well as possessing low attenuation The arithmetic mean between 30 W and 77 W is 53 5 W the geometric mean is 48 W The selection of 50 W as a compromise between power handling capability and attenuation is in general cited as the reason for the number 13 50 W also works out tolerably well because it corresponds approximately to the feedpoint impedance of a half wave dipole mounted approximately a half wave above normal ground ideally 73 W but reduced for low hanging horizontal wires RG 62 is a 93 W coaxial cable originally used in mainframe computer networks in the 1970s and early 1980s it was the cable used to connect IBM 3270 terminals to IBM 3274 3174 terminal cluster controllers Later some manufacturers of LAN equipment such as Datapoint for ARCNET adopted RG 62 as their coaxial cable standard The cable has the lowest capacitance per unit length when compared to other coaxial cables of similar size All of the components of a coaxial system should have the same impedance to avoid internal reflections at connections between components see Impedance matching Such reflections may cause signal attenuation They introduce standing waves which increase losses and can even result in cable dielectric breakdown with high power transmission In analog video or TV systems reflections cause ghosting in the image multiple reflections may cause the original signal to be followed by more than one echo If a coaxial cable is open not connected at the end the termination has nearly infinite resistance which causes reflections If the coaxial cable is short circuited the termination resistance is nearly zero which causes reflections with the opposite polarity Reflections will be nearly eliminated if the coaxial cable is terminated in a pure resistance equal to its impedance Coaxial characteristic impedance derivation EditTaking the characteristic impedance at high frequencies Z 0 L C displaystyle Z 0 sqrt frac L C One should also know the inductance and capacitance of the two concentric cylindrical conductors which is the coaxial cable By definition C Q V displaystyle C Q V and getting the electric field by the formula of electric field of an infinite line E Q 2 p ϵ o r r displaystyle vec E frac Q 2 pi epsilon o frac hat r r where Q displaystyle Q is charge ϵ o displaystyle epsilon o is the permittivity of free space r displaystyle r is the radial distance and r displaystyle hat r is the unit vector in the direction away from the axis The voltage V isV d 2 D 2 E r d r d 2 D 2 Q 2 p ϵ o r d r Q 2 p ϵ o ln D d displaystyle V int d 2 D 2 E cdot hat r dr int d 2 D 2 frac Q 2 pi epsilon o r dr frac Q 2 pi epsilon o ln frac D d where D displaystyle D is the inner diameter of the outer conductor and d displaystyle d is the diameter of the inner conductor The capacitance can then be solved by substitution C Q V 2 p ϵ o ln D d displaystyle C frac Q V frac 2 pi epsilon o ln frac D d and the inductance is taken from Ampere s Law for two concentric conductors coaxial wire and with the definition of inductance B m o I 2 p r displaystyle B frac mu o I 2 pi r and L ϕ I B I d S displaystyle L frac phi I int frac B I dS where B displaystyle B is magnetic induction m o displaystyle mu o is the permeability of free space ϕ displaystyle phi is the magnetic flux and d S displaystyle dS is the differential surface Taking the inductance per meter L d D m o 2 p r d r m o 2 p ln D d displaystyle L int limits d D frac mu o 2 pi r dr frac mu o 2 pi ln frac D d Substituting the derived capacitance and inductance and generalizing them to the case where a dielectric of permeability m displaystyle mu and permittivity ϵ displaystyle epsilon is used in between the inner and outer conductors Z 0 L C 1 2 p m ϵ ln D d displaystyle Z 0 sqrt frac L C frac 1 2 pi sqrt frac mu epsilon ln frac D d 15 Issues EditSignal leakage Edit Signal leakage is the passage of electromagnetic fields through the shield of a cable and occurs in both directions Ingress is the passage of an outside signal into the cable and can result in noise and disruption of the desired signal Egress is the passage of signal intended to remain within the cable into the outside world and can result in a weaker signal at the end of the cable and radio frequency interference to nearby devices Severe leakage usually results from improperly installed connectors or faults in the cable shield For example in the United States signal leakage from cable television systems is regulated by the FCC since cable signals use the same frequencies as aeronautical and radionavigation bands CATV operators may also choose to monitor their networks for leakage to prevent ingress Outside signals entering the cable can cause unwanted noise and picture ghosting Excessive noise can overwhelm the signal making it useless In channel ingress can be digitally removed by ingress cancellation An ideal shield would be a perfect conductor with no holes gaps or bumps connected to a perfect ground However a smooth solid highly conductive shield would be heavy inflexible and expensive Such coax is used for straight line feeds to commercial radio broadcast towers More economical cables must make compromises between shield efficacy flexibility and cost such as the corrugated surface of flexible hardline flexible braid or foil shields Since shields cannot be perfect conductors current flowing on the inside of the shield produces an electromagnetic field on the outer surface of the shield Consider the skin effect The magnitude of an alternating current in a conductor decays exponentially with distance beneath the surface with the depth of penetration being proportional to the square root of the resistivity This means that in a shield of finite thickness some small amount of current will still be flowing on the opposite surface of the conductor With a perfect conductor i e zero resistivity all of the current would flow at the surface with no penetration into and through the conductor Real cables have a shield made of an imperfect although usually very good conductor so there must always be some leakage The gaps or holes allow some of the electromagnetic field to penetrate to the other side For example braided shields have many small gaps The gaps are smaller when using a foil solid metal shield but there is still a seam running the length of the cable Foil becomes increasingly rigid with increasing thickness so a thin foil layer is often surrounded by a layer of braided metal which offers greater flexibility for a given cross section Signal leakage can be severe if there is poor contact at the interface to connectors at either end of the cable or if there is a break in the shield To greatly reduce signal leakage into or out of the cable by a factor of 1000 or even 10 000 superscreened cables are often used in critical applications such as for neutron flux counters in nuclear reactors Superscreened cables for nuclear use are defined in IEC 96 4 1 1990 however as there have been long gaps in the construction of nuclear power stations in Europe many existing installations are using superscreened cables to the UK standard AESS TRG 71181 16 which is referenced in IEC 61917 17 Ground loops Edit A continuous current even if small along the imperfect shield of a coaxial cable can cause visible or audible interference In CATV systems distributing analog signals the potential difference between the coaxial network and the electrical grounding system of a house can cause a visible hum bar in the picture This appears as a wide horizontal distortion bar in the picture that scrolls slowly upward Such differences in potential can be reduced by proper bonding to a common ground at the house See ground loop Noise Edit External fields create a voltage across the inductance of the outside of the outer conductor between sender and receiver The effect is less when there are several parallel cables as this reduces the inductance and therefore the voltage Because the outer conductor carries the reference potential for the signal on the inner conductor the receiving circuit measures the wrong voltage Transformer effect Edit The transformer effect is sometimes used to mitigate the effect of currents induced in the shield The inner and outer conductors form the primary and secondary winding of the transformer and the effect is enhanced in some high quality cables that have an outer layer of mu metal Because of this 1 1 transformer the aforementioned voltage across the outer conductor is transformed onto the inner conductor so that the two voltages can be cancelled by the receiver Many senders and receivers have means to reduce the leakage even further They increase the transformer effect by passing the whole cable through a ferrite core one or more times Common mode current and radiation Edit Common mode current occurs when stray currents in the shield flow in the same direction as the current in the center conductor causing the coax to radiate They are the opposite of the desired push pull differential signalling currents where the signal currents on the inner and outer conductor are equal and opposite Most of the shield effect in coax results from opposing currents in the center conductor and shield creating opposite magnetic fields that cancel and thus do not radiate The same effect helps ladder line However ladder line is extremely sensitive to surrounding metal objects which can enter the fields before they completely cancel Coax does not have this problem since the field is enclosed in the shield However it is still possible for a field to form between the shield and other connected objects such as the antenna the coax feeds The current formed by the field between the antenna and the coax shield would flow in the same direction as the current in the center conductor and thus not be canceled Energy would radiate from the coax itself affecting the radiation pattern of the antenna With sufficient power this could be a hazard to people near the cable A properly placed and properly sized balun can prevent common mode radiation in coax An isolating transformer or blocking capacitor can be used to couple a coaxial cable to equipment where it is desirable to pass radio frequency signals but to block direct current or low frequency power Higher impedance at audio frequencies Edit The characteristic impedance formula above is a good approximation at radio frequencies however for frequencies below 100 kHz such as audio it becomes important to use the complete telegrapher s equation Z o R j w L G j w C displaystyle Z text o sqrt frac R j omega L G j omega C Applying this formula to typical 75 ohm coax we find the measured impedance across the audio spectrum will range from 150 ohms to 5K ohms much higher than nominal The velocity of propagation also slows considerably Thus we can expect coax cable impedances to be consistent at RF frequencies but variable across audio frequencies This effect was manifested when trying to send a plain voice signal across the transatlantic telegraph cable with poor results 18 19 Standards EditThis section includes a list of general references but it lacks sufficient corresponding inline citations Please help to improve this section by introducing more precise citations June 2009 Learn how and when to remove this template message Most coaxial cables have a characteristic impedance of either 50 52 75 or 93 W The RF industry uses standard type names for coaxial cables Thanks to television RG 6 is the most commonly used coaxial cable for home use and the majority of connections outside Europe are by F connectors A series of standard types of coaxial cable were specified for military uses in the form RG or RG U They date from World War II and were listed in MIL HDBK 216 published in 1962 These designations are now obsolete The RG designation stands for Radio Guide the U designation stands for Universal The current military standard is MIL SPEC MIL C 17 MIL C 17 numbers such as M17 75 RG214 are given for military cables and manufacturer s catalog numbers for civilian applications However the RG series designations were so common for generations that they are still used although critical users should be aware that since the handbook is withdrawn there is no standard to guarantee the electrical and physical characteristics of a cable described as RG type The RG designators are mostly used to identify compatible connectors that fit the inner conductor dielectric and jacket dimensions of the old RG series cables Type Impedance ohms Core mm Dielectric Outside diameter Shields Remarks Max attenuation 750 MHz dB 100 ft Type VF in mm in mm RG 6 U 75 1 024 PF 0 75 0 185 4 7 0 270 6 86 Double Low loss at high frequency for cable television satellite television and cable modems 5 65RG 6 UQ 75 1 024 PF 0 75 0 185 4 7 0 298 7 57 Quad This is quad shield RG 6 It has four layers of shielding regular RG 6 has only one or two 5 65 20 RG 7 75 1 30 PF 0 225 5 72 0 320 8 13 Double Low loss at high frequency for cable television satellite television and cable modems 4 57RG 8 U 50 2 17 PE 0 285 7 2 0 405 10 3 Amateur radio Thicknet 10BASE5 is similar 5 97 21 RG 8X 50 1 47 PF 0 82 0 155 3 9 0 242 6 1 Single A thinner version with some of the electrical characteristics of RG 8U in a diameter similar to RG 59 22 10 95 21 RG 9 U 51 PE 0 420 10 7RG 11 U 75 1 63 PE 0 66 0 85 0 285 7 2 0 412 10 5 Dual triple quad Low loss at high frequency for cable and satellite television Used for long drops and underground conduit similar to RG7 but generally lower loss 23 24 3 65RG 56 U 48 1 4859 0 308 7 82 Dual braid shielded Rated to 8000 volts rubber dielectricRG 58 U 50 0 81 PE 0 66 0 116 2 9 0 195 5 0 Single Used for radiocommunication and amateur radio thin Ethernet 10BASE2 and NIM electronics Loss 1 056 dB m 2 4 GHz Common 25 13 10 21 RG 59 U 75 0 64 PE 0 66 0 146 3 7 0 242 6 1 Single Used to carry baseband video in closed circuit television previously used for cable television In general it has poor shielding but will carry an HQ HD signal or video over short distances 26 9 71 21 RG 59A U 75 0 762 PF 0 78 0 146 3 7 0 242 6 1 Single Similar physical characteristics as RG 59 and RG 59 U but with a higher velocity factor 8 9 700 MHz 8 9 27 3C 2V 75 0 50 PE 0 85 3 0 5 4 Single Used to carry television video observation systems and other PVC jacket 5C 2V 75 0 80 PE 0 82 0 02 0 181 4 6 0 256 6 5 Double Used for interior lines for monitoring system CCTV feeder lines wiring between the camera and control unit and video signal transmission PVC jacket RG 60 U 50 1 024 PE 0 425 10 8 Single Used for high definition cable TV and high speed cable Internet RG 62 U 92 PF 0 84 0 242 6 1 Single Used for ARCNET and automotive radio antennas 28 RG 62A 93 ASP 0 242 6 1 Single Used for NIM electronicsRG 63 125 1 2 PE 0 405 10 29 Double braid Used for aerospace 4 6RG 142 U 50 0 94 PTFE 0 116 2 95 0 195 4 95 Double braid Used for test equipment 9 6RG 174 U 50 0 5 7 0 16 PE 0 66 0 059 1 5 0 100 2 55 Single Common for Wi Fi pigtails more flexible but higher loss than RG58 used with LEMO 00 connectors in NIM electronics 23 57 21 RG 178 U 50 0 31 7 0 1 PTFE 0 69 0 033 0 84 0 071 1 8 Single Used for high frequency signal transmission 42 7 900 MHz 29 Core material Ag plated Cu clad Steel 42 7 30 RG 179 U 75 0 31 7 0 1 PTFE 0 67 0 063 1 6 0 098 2 5 Single VGA RGBHV 31 Core material Ag plated CuRG 180B U 95 0 31 PTFE 0 102 2 59 0 145 3 68 Single silver covered copper VGA RGBHV Core material Ag plated Cu clad steelRG 188A U 50 0 5 7 0 16 PTFE 0 70 0 06 1 52 0 1 2 54 Single 26 2 1000 MHz Core material Ag plated Cu clad steel 26 2 32 RG 195 95 0 305 PTFE 0 102 2 59 0 145 3 68 Single PTFE jacket suitable for direct burial Core material Ag plated Cu clad steel 33 RG 213 U 50 2 26 7 0 75 PE 0 66 0 285 7 2 0 405 10 3 Single For radiocommunication and amateur radio EMC test antenna cables Typically lower loss than RG58 Common 34 5 98 21 RG 214 U 50 2 26 7 0 75 PE 0 66 0 285 7 2 0 425 10 8 Double Used for high frequency signal transmission 35 6 7 21 RG 218 50 4 963 PE 0 66 0 660 0 680 16 76 17 27 0 870 22 Single Large diameter not very flexible low loss 2 5 dB 100 ft 400 MHz 11 kV dielectric withstand 2 83 21 RG 223 U 50 0 88 PE 0 66 0 0815 2 07 0 212 5 4 Double Silver plated shields Sample RG 223 Datasheet 11 46 21 RG 316 U 50 0 51 7 0 17 PTFE 0 695 0 060 1 5 0 098 2 6 Single Used with LEMO 00 connectors in NIM electronics 36 22 45 21 RG 400 U 50 1 0 19 0 20 PTFE 2 95 4 95 Double 37 12 57 21 RG 402 U 50 0 93 PTFE 3 0 0 141 3 58 Single silver plated copper Semi rigid 0 91 dB m 5 GHz 27 7RG 405 U 50 0 51 PTFE 1 68 0 0865 2 20 Single silver plated copper clad steel Semi rigid 1 51 dB m 5 GHz 46 0H155 50 1 41 19 0 28 PF 0 79 0 0984 2 5 0 2126 5 4 Double Lower loss at high frequency for radiocommunication and amateur radioH500 50 2 5 PF 0 81 0 1772 4 5 0 386 9 8 Double Low loss at high frequency for radiocommunication and amateur radio 4 45 1000 MHz 4 45 38 LMR 100 50 0 46 PE 0 66 0 0417 1 06 0 110 2 79 Double Low loss communications 1 36 dB meter 2 4 GHz 20 7 21 LMR 195 50 0 94 PF 0 80 0 073 1 85 0 195 4 95 Double Low loss communications 0 620 dB meter 2 4 GHz 10 1 21 LMR 200HDF 200CFD 200 50 1 12 PF 0 83 0 116 2 95 0 195 4 95 Double Low loss communications 0 554 dB meter 2 4 GHz 9 0 21 LMR 240EMR 240 50 1 42 PF 0 84 0 150 3 81 0 240 6 1 Double Amateur radio low loss replacement for RG 8X 39 6 9 21 LMR 300 50 1 78 PF 0 82 0 190 4 83 0 300 7 62 Foil Braid Low loss communications 5 5 21 LMR 400HDF 400CFD 400EMR 400 50 2 74 PF 0 85 0 285 7 24 0 405 10 29 Double Low loss communications 0 223 dB meter 2 4 GHz 40 Core material Cu clad Al 3 5 21 LMR 500 50 3 61 PF 0 86 0 370 9 4 0 500 12 7 Double Low loss communications Core material Cu clad Al 2 8 21 LMR 600 50 4 47 PF 0 87 0 455 11 56 0 590 14 99 Double Low loss communications 0 144 dB meter 2 4 GHz Core material Cu clad Al 2 3 21 LMR 900 50 6 65 PF 0 87 0 680 17 27 0 870 22 10 Double Low loss communications 0 098 dB meter 2 4 GHz Core material BC tube 1 5 21 LMR 1200 50 8 86 PF 0 88 0 920 23 37 1 200 30 48 Double Low loss communications 0 075 dB meter 2 4 GHz Core material BC tube 1 3 21 LMR 1700 50 13 39 PF 0 89 1 350 34 29 1 670 42 42 Double Low loss communications 0 056 dB meter 2 4 GHz Core material BC tube 0 8 21 LDF4 50A 5 50 4 83 FPE 0 88 0 51 12 96 0 55 13 97 corrugated copper Heliax Cellflex low loss semi flexible 1 90AVA5 50 50 9 45 FPE 0 88 0 95 24 1 1 000 25 4 corrugated copper Heliax Cellflex low loss semi flexible 0 98AVA7 50 50 18 6 FPE 0 92 1 75 44 5 1 825 46 4 corrugated copper Heliax Cellflex low loss semi flexible 0 58HCA214 50J 50 22 7 Air 0 95 1 96 49 9 2 37 60 2 corrugated copper Semi flexible hardline 0 50HCA300 50J 50 29 3 Air 0 96 2 50 63 5 2 99 76 0 corrugated copper Semi flexible hardline 0 39HCA400 50J 50 34 8 Air 0 96 2 96 75 3 3 56 90 5 corrugated copper Semi flexible hardline 0 33HCA495 50J 50 45 0 Air 0 97 3 86 98 1 4 53 115 1 corrugated copper Semi flexible hardline 0 25HCA550 50J 50 58 0 Air 0 96 5 00 127 1 5 79 147 1 corrugated copper Semi flexible hardline 0 20HCA618 50J 50 67 0 Air 0 97 5 78 147 0 6 65 169 corrugated copper Semi flexible hardline 0 17HCA800 50J 50 88 5 Air 0 97 7 67 195 0 8 78 223 0 corrugated copper Semi flexible hardline 650 MHz max HCA900 50T 50 99 4 Air 0 98 8 53 216 7 9 75 247 7 corrugated aluminum Semi flexible hardline 560 MHz max QR 320 75 1 80 PF 0 395 10 03 Single Low loss line which replaced RG 11 in most applications 3 34QR 540 75 3 15 PF 0 610 15 49 Single Low loss hard line 1 85QR 715 75 4 22 PF 0 785 19 94 Single Low loss hard line 1 49QR 860 75 5 16 PF 0 960 24 38 Single Low loss hard line 1 24QR 1125 75 6 68 PF 1 225 31 12 Single Low loss hard line 1 01Type Impedance ohms Core mm Dielectric Outside diameter Shields Remarks Max attenuation 750 MHz dB 100 ft Type VF in mm in mm Dielectric material codes FPE is foamed polyethylene PE is solid polyethylene PF is polyethylene foam PTFE is polytetrafluoroethylene ASP is air space polyethylene 41 VF is the Velocity Factor it is determined by the effective ϵ r displaystyle epsilon r and m r displaystyle mu r 42 VF for solid PE is about 0 66 VF for foam PE is about 0 78 to 0 88 VF for air is about 1 00 VF for solid PTFE is about 0 70 VF for foam PTFE is about 0 84There are also other designation schemes for coaxial cables such as the URM CT BT RA PSF and WF series RG 6 coaxial cable RG 142 coaxial cable RG 405 semi rigid coaxial cable High end coaxial audio cable S PDIF Uses EditThis section does not cite any sources Please help improve this section by adding citations to reliable sources Unsourced material may be challenged and removed June 2009 Learn how and when to remove this template message Short coaxial cables are commonly used to connect home video equipment in ham radio setups and in NIM While formerly common for implementing computer networks in particular Ethernet thick 10BASE5 and thin 10BASE2 twisted pair cables have replaced them in most applications except in the growing consumer cable modem market for broadband Internet access Long distance coaxial cable was used in the 20th century to connect radio networks television networks and Long Distance telephone networks though this has largely been superseded by later methods fibre optics T1 E1 satellite Shorter coaxials still carry cable television signals to the majority of television receivers and this purpose consumes the majority of coaxial cable production In 1980s and early 1990s coaxial cable was also used in computer networking most prominently in Ethernet networks where it was later in late 1990s to early 2000s replaced by UTP cables in North America and STP cables in Western Europe both with 8P8C modular connectors Micro coaxial cables are used in a range of consumer devices military equipment and also in ultra sound scanning equipment The most common impedances that are widely used are 50 or 52 ohms and 75 ohms although other impedances are available for specific applications The 50 52 ohm cables are widely used for industrial and commercial two way radio frequency applications including radio and telecommunications although 75 ohms is commonly used for broadcast television and radio Coax cable is often used to carry data signals from an antenna to a receiver from a satellite dish to a satellite receiver from a television antenna to a television receiver from a radio mast to a radio receiver etc In many cases the same single coax cable carries power in the opposite direction to the antenna to power the low noise amplifier In some cases a single coax cable carries unidirectional power and bidirectional data signals as in DiSEqC Types EditHard line Edit 1 5 8 in 41 mm flexible line with mostly air dielectric 1 5 8 in 41 mm Heliax coaxial cable with Cellflex FPE foamed polyethylene dielectric Hard line is used in broadcasting as well as many other forms of radio communication It is a coaxial cable constructed using round copper silver or gold tubing or a combination of such metals as a shield Some lower quality hard line may use aluminum shielding Aluminum however is easily oxidized and unlike silver oxide aluminum oxide drastically loses effective conductivity Therefore all connections must be air and water tight The center conductor may consist of solid copper or copper plated aluminum Since skin effect is an issue with RF copper plating provides sufficient surface for an effective conductor Most varieties of hardline used for external chassis or when exposed to the elements have a PVC jacket however some internal applications may omit the insulation jacket Hard line can be very thick typically at least a half inch or 13 mm and up to several times that and has low loss even at high power These large scale hard lines are almost always used in the connection between a transmitter on the ground and the antenna or aerial on a tower Hard line may also be known by trademarked names such as Heliax CommScope 43 or Cablewave RFS Cablewave 44 Larger varieties of hardline may have a center conductor that is constructed from either rigid or corrugated copper tubing The dielectric in hard line may consist of polyethylene foam air or a pressurized gas such as nitrogen or desiccated air dried air In gas charged lines hard plastics such as nylon are used as spacers to separate the inner and outer conductors The addition of these gases into the dielectric space reduces moisture contamination provides a stable dielectric constant and provides a reduced risk of internal arcing Gas filled hardlines are usually used on high power RF transmitters such as television or radio broadcasting military transmitters and high power amateur radio applications but may also be used on some critical lower power applications such as those in the microwave bands However in the microwave region waveguide is more often used than hard line for transmitter to antenna or antenna to receiver applications The various shields used in hard line also differ some forms use rigid tubing or pipe while others may use a corrugated tubing which makes bending easier as well as reduces kinking when the cable is bent to conform Smaller varieties of hard line may be used internally in some high frequency applications in particular in equipment within the microwave range to reduce interference between stages of the device Radiating Edit Main article Leaky feeder Radiating or leaky cable is another form of coaxial cable which is constructed in a similar fashion to hard line however it is constructed with tuned slots cut into the shield These slots are tuned to the specific RF wavelength of operation or tuned to a specific radio frequency band This type of cable is to provide a tuned bi directional desired leakage effect between transmitter and receiver It is often used in elevator shafts US Navy Ships underground transportation tunnels and in other areas where an antenna is not feasible One example of this type of cable is Radiax CommScope 45 RG 6 Edit Main article RG 6 RG 6 is available in four different types designed for various applications In addition the core may be copper clad steel CCS or bare solid copper BC Plain or house RG 6 is designed for indoor or external house wiring Flooded cable is infused with waterblocking gel for use in underground conduit or direct burial Messenger may contain some waterproofing but is distinguished by the addition of a steel messenger wire along its length to carry the tension involved in an aerial drop from a utility pole Plenum cabling is expensive and comes with a special Teflon based outer jacket designed for use in ventilation ducts to meet fire codes It was developed since the plastics used as the outer jacket and inner insulation in many Plain or house cabling gives off poisonous gas when burned Triaxial cable Edit Main article Triaxial cable Triaxial cable or triax is coaxial cable with a third layer of shielding insulation and sheathing The outer shield which is earthed grounded protects the inner shield from electromagnetic interference from outside sources Twin axial cable Edit Main article Twinaxial cabling Twin axial cable or twinax is a balanced twisted pair within a cylindrical shield It allows a nearly perfect differential signalling which is both shielded and balanced to pass through Multi conductor coaxial cable is also sometimes used Semi rigid Edit Semi rigid coax assembly Semi rigid coax installed in an Agilent N9344C 20GHz spectrum analyser Semi rigid cable is a coaxial form using a solid copper outer sheath This type of coax offers superior screening compared to cables with a braided outer conductor especially at higher frequencies The major disadvantage is that the cable as its name implies is not very flexible and is not intended to be flexed after initial forming See Hard line Conformable cable is a flexible reformable alternative to semi rigid coaxial cable used where flexibility is required Conformable cable can be stripped and formed by hand without the need for specialized tools similar to standard coaxial cable Rigid line Edit Rigid line is a coaxial line formed by two copper tubes maintained concentric every other meter using PTFE supports Rigid lines cannot be bent so they often need elbows Interconnection with rigid line is done with an inner bullet inner support and a flange or connection kit Typically rigid lines are connected using standardised EIA RF Connectors whose bullet and flange sizes match the standard line diameters For each outer diameter either 75 or 50 ohm inner tubes can be obtained Rigid line is commonly used indoors for interconnection between high power transmitters and other RF components but more rugged rigid line with weatherproof flanges is used outdoors on antenna masts etc In the interests of saving weight and costs on masts and similar structures the outer line is often aluminium and special care must be taken to prevent corrosion With a flange connector it is also possible to go from rigid line to hard line Many broadcasting antennas and antenna splitters use the flanged rigid line interface even when connecting to flexible coaxial cables and hard line Rigid line is produced in a number of different sizes Size Outer conductor Inner conductorOuter diameter not flanged Inner diameter Outer diameter Inner diameter7 8 22 2 mm 20 mm 8 7 mm 7 4 mm1 5 8 41 3 mm 38 8 mm 16 9 mm 15 0 mm3 1 8 79 4 mm 76 9 mm 33 4 mm 31 3 mm4 1 2 106 mm 103 mm 44 8 mm 42 8 mm6 1 8 155 6 mm 151 9 mm 66 0 mm 64 0 mmCables used in the UK Edit This section does not cite any sources Please help improve this section by adding citations to reliable sources Unsourced material may be challenged and removed February 2017 Learn how and when to remove this template message At the start of analog satellite TV broadcasts in the UK by Sky a 75 ohm cable referred to as RG6 was used This cable had a 1 mm copper core air spaced polyethylene dielectric and copper braid on an aluminum foil shield When installed outdoors without protection the cable was affected by UV radiation which cracked the PVC outer sheath and allowed moisture ingress The combination of copper aluminum moisture and air caused rapid corrosion sometimes resulting in a snake swallowed an egg appearance Consequently despite the higher cost the RG6 cable was dropped in favor of CT100 when Sky launched its digital broadcasts From around 1999 to 2005 when CT100 manufacturer Raydex went out of business CT100 remained the 75 ohm cable of choice for satellite TV and especially Sky It had an air spaced polyethylene dielectric a 1 mm solid copper core and copper braid on copper foil shield CT63 was a thinner cable in shotgun style meaning that it was two cables molded together and was used mainly by Sky for the twin connection required by the Sky satellite TV receiver which incorporated a hard drive recording system and a second independent tuner In 2005 these cables were replaced by WF100 and WF65 respectively manufactured by Webro and having a similar construction but a foam dielectric that provided the same electrical performance as air spaced but was more robust and less likely to be crushed At the same time with the price of copper steadily rising the original RG6 was dropped in favor of a construction that used a copper clad steel core and aluminum braid on aluminum foil Its lower price made it attractive to aerial installers looking for a replacement for the so called low loss cable traditionally used for UK terrestrial aerial installations This cable had been manufactured with a decreasing number of strands of braid as the price of copper increased such that the shielding performance of cheaper brands had fallen to as low as 40 percent With the advent of digital terrestrial transmissions in the UK this low loss cable was no longer suitable The new RG6 still performed well at high frequencies because of the skin effect in the copper cladding However the aluminum shield had a high DC resistance and the steel core an even higher one The result is that this type of cable could not reliably be used in satellite TV installations where it was required to carry a significant amount of current because the voltage drop affected the operation of the low noise block downconverter LNB on the dish A problem with all the aforementioned cables when passing current is that electrolytic corrosion can occur in the connections unless moisture and air are excluded Consequently various solutions to exclude moisture have been proposed The first was to seal the connection by wrapping it with self amalgamating rubberized tape which bonds to itself when activated by stretching The second proposal by the American Channel Master company now owned by Andrews corp at least as early as 1999 was to apply silicone grease to the wires making connection The third proposal was to fit a self sealing plug to the cable All of these methods are reasonably successful if implemented correctly Interference and troubleshooting EditThis section does not cite any sources Please help improve this section by adding citations to reliable sources Unsourced material may be challenged and removed June 2009 Learn how and when to remove this template message Coaxial cable insulation may degrade requiring replacement of the cable especially if it has been exposed to the elements on a continuous basis The shield is normally grounded and if even a single thread of the braid or filament of foil touches the center conductor the signal will be shorted causing significant or total signal loss This most often occurs at improperly installed end connectors and splices Also the connector or splice must be properly attached to the shield as this provides the path to ground for the interfering signal Despite being shielded interference can occur on coaxial cable lines Susceptibility to interference has little relationship to broad cable type designations e g RG 59 RG 6 but is strongly related to the composition and configuration of the cable s shielding For cable television with frequencies extending well into the UHF range a foil shield is normally provided and will provide total coverage as well as high effectiveness against high frequency interference Foil shielding is ordinarily accompanied by a tinned copper or aluminum braid shield with anywhere from 60 to 95 coverage The braid is important to shield effectiveness because 1 it is more effective than foil at preventing low frequency interference 2 it provides higher conductivity to ground than foil and 3 it makes attaching a connector easier and more reliable Quad shield cable using two low coverage aluminum braid shields and two layers of foil is often used in situations involving troublesome interference but is less effective than a single layer of foil and single high coverage copper braid shield such as is found on broadcast quality precision video cable In the United States and some other countries cable television distribution systems use extensive networks of outdoor coaxial cable often with in line distribution amplifiers Leakage of signals into and out of cable TV systems can cause interference to cable subscribers and to over the air radio services using the same frequencies as those of the cable system History Edit Early coaxial antenna feedline of 50 kW radio station WNBC New York 1930s AT amp T coaxial cable trunkline installed between East Coast and Midwest in 1948 Each of the 8 coaxial subcables could carry 480 telephone calls or one television channel 1858 Coaxial cable used in first 1858 transatlantic cable 46 1880 Coaxial cable patented in England by Oliver Heaviside patent no 1 407 47 1884 Siemens amp Halske patent coaxial cable in Germany Patent No 28 978 27 March 1884 48 1894 Nikola Tesla U S Patent 514 167 1929 First modern coaxial cable patented by Lloyd Espenschied and Herman Affel of AT amp T s Bell Telephone Laboratories 49 1936 First closed circuit transmission of TV pictures on coaxial cable from the 1936 Summer Olympics in Berlin to Leipzig 50 1936 Underwater coaxial cable installed between Apollo Bay near Melbourne Australia and Stanley Tasmania The 300 km 190 mi cable can carry one 8 5 kHz broadcast channel and seven telephone channels 51 1936 AT amp T installs experimental coaxial telephone and television cable between New York and Philadelphia with automatic booster stations every ten miles 16 km Completed in December it can transmit 240 telephone calls simultaneously 52 53 1936 Coaxial cable laid by the General Post Office now BT between London and Birmingham providing 40 telephone channels 54 55 1941 First commercial use in USA by AT amp T between Minneapolis Minnesota and Stevens Point Wisconsin L1 system with capacity of one TV channel or 480 telephone circuits 1949 On January 11 eight stations on the US East Coast and seven Midwestern stations are linked via a long distance coaxial cable 56 1956 First transatlantic telephone coaxial cable laid TAT 1 57 58 1962 960 km 600 mi Sydney Melbourne co axial cable commissioned carrying 3 x 1 260 simultaneous telephone connections and or simultaneous inter city television transmission 59 60 See also EditBalanced line BNC Connector LEMO Connector Radio frequency power transmissionReferences Edit Nahin Paul J 2002 Oliver Heaviside The Life Work and Times of an Electrical Genius of the Victorian Age ISBN 0 8018 6909 9 a b Silver H Ward N0AX Wilson Mark J K1RO eds 2010 Chapter 20 Transmission Lines The ARRL Handbook for Radio Communications 87th ed The American Radio Relay League ISBN 978 0 87259 144 8 van der Burgt Martin J Coaxial Cables and Applications PDF Belden p 4 Archived from the original PDF on 28 July 2011 Retrieved 11 July 2011 a b c d e 5 Transmission Media The ARRL UHF Microwave Experimenter s Manual Newington CT American Radio Relay League 1990 pp 5 19 5 21 ISBN 0872593126 a b CommScope product specifications LDF4 50A PDF Archived from the original PDF on 2017 07 13 Retrieved May 25 2017 a b Jackson John David 1962 Classical Electrodynamics PDF New York John Wiley amp Sons Inc p 244 Archived PDF from the original on 2021 10 27 White Bronze Copper Tin Zinc Tri metal Expanding Applications and New Developments in a Changing Landscape PDF National Association for Surface Finishing June 2013 Archived PDF from the original on 2022 03 06 Pozar David M 1993 Microwave Engineering Addison Wesley Publishing Company ISBN 0201504189 Ott Henry W 1976 Noise Reduction Techniques in Electronic Systems ISBN 0 471 65726 3 Elmore William C Heald Mark A 1985 Physics of Waves ISBN 0 486 64926 1 Kizer George Maurice 1990 Microwave communication Iowa State University Press p 312 ISBN 978 0 8138 0026 4 Coax power handling Archived from the original on 14 July 2014 a b Why 50 Ohms Microwaves 101 13 January 2009 Archived from the original on 14 July 2014 Coax power handling Microwaves 101 14 September 2008 Archived from the original on 28 January 2012 Coaxial Cable Equations Formulas RF Cafe Archived from the original on 2012 01 19 Retrieved 2012 01 25 AESS TRG 71181 Part 2 May 1977 Superscreened co axial cables for the nuclear power industry May 1977 a href Template Cite journal html title Template Cite journal cite journal a Cite journal requires journal help IEC 61917 Cables cable assemblies and connectors Introduction to electromagnetic EMC screening measurements First edition 1998 06 PDF permanent dead link Silver H Ward Ford Steven R Wilson Mark J eds 2015 23 1 2 ARRL Antenna Book for Radio Communications 23rd ed Netwon CT ARRL ISBN 978 1 62595 044 4 Brown Jim 2008 Transmission Lines at Audio Frequencies and a Bit of History PDF The Audio Systems Group Inc Retrieved 2023 01 16 Coaxial Cable Specifications for RG 6 madaboutcable com Archived from the original on 2010 08 13 Retrieved 2011 06 28 a b c d e f g h i j k l m n o p q r s t u v Times Microwave Coax Loss Calculator Retrieved 2011 10 26 http www dxengineering com pdf Belden 20RG8X 20Date 209258 pdf bare URL PDF Coaxial Cable Specifications for RG 11 madaboutcable com Archived from the original on 2010 08 11 Retrieved 2011 03 29 Belden 7731A RG11 Coax PDF belden com Archived from the original PDF on 2018 02 24 Retrieved 2018 02 23 Coaxial Cable Specifications for RG 58 madaboutcable com Archived from the original on 2010 08 09 Retrieved 2011 03 29 Coaxial Cable Specifications for RG 59 madaboutcable com Archived from the original on 2010 08 11 Retrieved 2011 03 29 Cable Velocity Factor and Loss Data febo com Coaxial Cable Specifications for RG 62 madaboutcable com Archived from the original on 2010 08 11 Retrieved 2011 03 29 Coaxial Cable Specifications for RG 178 madaboutcable com Archived from the original on 2011 09 28 Retrieved 2011 04 11 RG178 Mini Coax Coaxial Cable Specifications for 5 Core RG 179 RGBHV madaboutcable com Archived from the original on 2012 03 30 Retrieved 2011 06 28 http www wellshow com spec cable Harbour RG188 pdf bare URL PDF RG195 Coax Cable Allied Wire amp Cable Archived from the original on 2021 08 17 Retrieved 2021 08 17 Coaxial Cable Specifications for RG 213 madaboutcable com Archived from the original on 2011 09 26 Retrieved 2011 06 28 Coaxial Cable Specifications for RG 214 madaboutcable com Archived from the original on 2010 10 08 Retrieved 2011 03 29 Coaxial Cable Specifications for RG 316 madaboutcable com Archived from the original on 2010 08 11 Retrieved 2011 06 28 Coaxial Cable Specifications for RG 400 madaboutcable com Archived from the original on 2011 09 28 Retrieved 2011 06 28 http www dnd hu uploads termek doc Belden h500pe en pdf bare URL PDF Times Microwave LMR 240 Data Sheet PDF Archived from the original PDF on 2011 10 18 Retrieved 2011 10 26 Radio City Inc Archived from the original on 2008 12 07 Retrieved 2009 02 06 Coaxial Cable Specifications Cables Chart RF Cafe Archived from the original on 2012 01 03 Retrieved 2012 01 25 Phase Velocity Microwaves 101 2010 03 30 Archived from the original on 2012 01 14 Retrieved 2012 01 25 CommScope Heliax Archived from the original on 2016 06 28 Retrieved 2016 06 28 Cablewave Radio Frequency Systems Archived from the original on 2007 12 02 Retrieved 2007 12 04 CommScope Radiax Archived from the original on 2016 05 30 Retrieved 2016 06 28 Coaxial cable used in first Transatlantic telegraph cable Harper s Weekly 38 447 448 May 12 1894 ISBN 9780801869099 Nahin Paul J 13 November 2002 3 The First Theory of the Electric Telegraph Oliver Heaviside ISBN 9780801869099 Feldenkirchen Wilfried 1994 Werner von Siemens Inventor and International Entrepreneur ISBN 0 8142 0658 1 U S Patent 1 835 031 Early Electronic Television The 1936 Berlin Olympics earlytelevision org Archived from the original on 2007 12 03 Huurdeman Anton A 31 July 2003 Copper Line Transmission The worldwide history of telecommunications ISBN 9780471205050 Coaxial Debut Time December 14 1936 Archived from the original on 2007 10 13 Gallery An illustrated history of the transoceanic cable Boing Boing Tozer Edwin Paul J 2004 Broadcast engineer s reference book ISBN 9780240519081 Coaxial feeder or RF coax cable Radio electronics com Teachout Terry The New Media Crisis of 1949 Wall Street Journal Retrieved 19 January 2015 1956 TAT 1 Silver Commemorative Dish Atlantic cable com Huurdeman Anton A 31 July 2003 The worldwide history of telecommunications ISBN 9780471205050 Australia s Prime Ministers National Archives of Australia Archived from the original on 4 August 2017 Retrieved 14 September 2013 The Australasian Engineer 1962 p 33 External links Edit Wikimedia Commons has media related to Coaxial cables RF Transmission Lines and Fittings Military Standardization Handbook MIL HDBK 216 U S Department of Defense 4 January 1962 1 Cables Radio Frequency Flexible and Rigid Details Specification MIL DTL 17H 19 August 2005 superseding MIL C 17G 9 March 1990 2 The Electromagnetic Theory of Coaxial Transmission Lines and Cylindrical Shields Bell System Technical Journal 13 4 October 1934 Brooke Clarke Transmission Line Zo vs Frequency Retrieved from https en wikipedia org w index php title Coaxial cable amp oldid 1149360070, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.