Components of an electrical circuit are electrically connected if an electric current can run between them through an electrical conductor. An electrical connector is an electromechanical device used to create an electrical connection between parts of an electrical circuit, or between different electrical circuits, thereby joining them into a larger circuit.[1] Most electrical connectors have a gender – i.e. the male component, called a plug, connects to the female component, or socket. The connection may be removable (as for portable equipment), require a tool for assembly and removal, or serve as a permanent electrical joint between two points.[2] An adapter can be used to join dissimilar connectors.

Schematic symbols for male and female connectors (see Gender of connectors and fasteners)
This rear panel of an integrated amplifier features a variety of electrical connectors
Connectors on the back of a 2018 computer

Thousands of configurations of connectors are manufactured for power, data, and audiovisual applications.[3] Electrical connectors can be divided into four basic categories, differentiated by their function:[4]

In computing, electrical connectors are considered a physical interface and constitute part of the physical layer in the OSI model of networking.

Physical construction

In addition to the classes mentioned above, connectors are characterised by their pinout, method of connection, materials, size, contact resistance, insulation, mechanical durability, ingress protection, lifetime (number of cycles), and ease of use.

It is usually desirable for a connector to be easy to identify visually, rapid to assemble, inexpensive, and require only simple tooling. In some cases an equipment manufacturer might choose a connector specifically because it is not compatible with those from other sources, allowing control of what may be connected. No single connector has all the ideal properties for every application; the proliferation of types is a result of the diverse yet specific requirements of manufacturers.[7]: 6 

Materials

Electrical connectors essentially consist of two classes of materials: conductors and insulators. Properties important to conductor materials are contact resistance, conductivity, mechanical strength, formability, and resilience.[8] Insulators must have a high electrical resistance, withstand high temperatures, and be easy to manufacture for a precise fit.

Electrodes in connectors are usually made of copper alloys, due to their good conductivity and malleability.[7]: 15  Alternatives include brass, phosphor bronze, and beryllium copper. The base electrode metal is often coated with another inert metal such as gold, nickel, or tin.[8] The use of a coating material with good conductivity, mechanical robustness and corrosion resistance helps to reduce the influence of passivating oxide layers and surface adsorbates, which limit metal-to-metal contact patches and contribute to contact resistance. For example, copper alloys have favorable mechanical properties for electrodes, but are hard to solder and prone to corrosion. Thus, copper pins are usually coated with gold to alleviate these pitfalls, especially for analog signals and high reliability applications.[9][10]

Contact carriers that hold the parts of a connector together are usually made of plastic, due to its insulating properties. Housings or backshells can be made of molded plastic and metal.[7]: 15  Connector bodies for high-temperature use, such as thermocouples or associated with large incandescent lamps, may be made of fired ceramic material.

Failure modes

The majority of connector failures result in intermittent connections or open contacts:[11][12]

Failure mode Relative probability
Open circuit 61%
Poor contact 23%
Short circuit 16%

Connectors are purely passive components – that is, they do not enhance the function of a circuit – so connectors should affect the function of a circuit as little as possible. Insecure mounting of connectors (primarily chassis-mounted) can contribute significantly to the risk of failure, especially when subjected to extreme shock or vibration.[11] Other causes of failure are connectors inadequately rated for the applied current and voltage, connectors with inadequate ingress protection, and threaded backshells that are worn or damaged.

High temperatures can also cause failure in connectors, resulting in an "avalanche" of failures – ambient temperature increases, leading to a decrease in insulation resistance and increase in conductor resistance; this increase generates more heat, and the cycle repeats.[11]

Fretting (so-called dynamic corrosion) is a common failure mode in electrical connectors that have not been specifically designed to prevent it, especially in those that are frequently mated and de-mated.[13] Surface corrosion is a risk for many metal parts in connectors, and can cause contacts to form a thin surface layer that increases resistance, thus contributing to heat buildup and intermittent connections.[14] However, remating or reseating a connector can alleviate the issue of surface corrosion, since each cycle scrapes a microscopic layer off the surface of the contact(s), exposing a fresh, unoxidised surface.

Circular connectors

Many connectors used for industrial and high-reliability applications are circular in cross section, with a cylindrical housing and circular contact interface geometries. This is in contrast to the rectangular design of some connectors, e.g. USB or blade connectors. They are commonly used for easier engagement and disengagement, tight environmental sealing, and rugged mechanical performance.[15] They are widely used in military, aerospace, industrial machinery, and rail, where MIL-DTL-5015 and MIL-DTL-38999 are commonly specified. Fields such as sound engineering and radio communication also use circular connectors, such as XLR and BNC. AC power plugs are also commonly circular, for example, Schuko plugs and IEC 60309.

 
NMEA 2000 cabling using M12 connectors

The M12 connector, specified in IEC 61076-2-101, is a circular electrical plug/receptacle pair with 12mm OD mating threads, used in NMEA 2000, DeviceNet, IO-Link, some kinds of Industrial Ethernet, etc.[16][17]

A disadvantage of the circular design is its inefficient use of panel space when used in arrays, when compared to rectangular connectors.

Circular connectors commonly use backshells, which provide physical and electromagnetic protection, whilst sometimes also providing a method for locking the connector into a receptacle.[18] In some cases, this backshell provides a hermetic seal, or some degree of ingress protection, through the use of grommets, O-rings, or potting.[15]

Hybrid connectors

Hybrid connectors allow the intermixing of many connector types, usually by way of a housing with inserts.[19] These housings may also allow intermixing of electrical and non-electrical interfaces, examples of the latter being pneumatic line connectors, and optical fiber connectors. Because hybrid connectors are modular in nature, they tend to simplify assembly, repair, and future modifications. They also allow the creation of composite cable assemblies that can reduce equipment installation time by reducing the number of individual cable and connector assemblies.

Mechanical features

Pin sequence

Some connectors are designed such that certain pins make contact before others when inserted, and break first on disconnection.[1] This is often used in power connectors to protect equipment, e.g. connecting safety ground first. It is also employed for digital signals, as a method to sequence connections properly in hot swapping.

Keying

Examples of keyed connectors
 
XLR connector, showing the notch for alignment
 
A 4-pin Mini-DIN S-Video cable, with notches and a rectangular alignment pin

Many connectors are keyed with some mechanical component (sometimes called a keyway), which prevents mating in an incorrect orientation.[20] This can be used to prevent mechanical damage to connectors, from being jammed in at the wrong angle or into the wrong connector, or to prevent incompatible or dangerous electrical connections, such as plugging an audio cable into a power outlet.[1] Keying also prevents otherwise symmetrical connectors from being connected in the wrong orientation or polarity. Keying is particularly important for situations where there are many similar connectors, such as in signal electronics.[7]: 26  For instance, XLR connectors have a notch to ensure proper orientation, while Mini-DIN plugs have a plastic projection that fits into a corresponding hole in the socket (they also have a notched metal skirt to provide secondary keying).[21]

Locking mechanisms

Some connector housings are designed with locking mechanisms to prevent inadvertent disconnection or poor environmental sealing.[1] Locking mechanism designs include locking levers of various sorts, jackscrews, screw-in shells, push-pull connector, and toggle or bayonet systems. Some connectors, particularly those with large numbers of contacts, require high forces to connect and disconnect. Locking levers and jackscrews and screw-in shells for such connectors frequently serve both to retain the connector when connected and to provide the force needed for connection and disconnection. Depending on application requirements, housings with locking mechanisms may be tested under various environmental simulations that include physical shock and vibration, water spray, dust, etc. to ensure the integrity of the electrical connection and housing seals.

Backshells

Backshells are a common accessory for industrial and high-reliability connectors, especially circular connectors.[18] Backshells typically protect the connector and/or cable from environmental or mechanical stress, or shield it from electromagnetic interference.[22] Many types of backshells are available for different purposes, including various sizes, shapes, materials, and levels of protection. Backshells usually lock onto the cable with a clamp or moulded boot, and may be threaded for attachment to a mating receptacle.[23] Backshells for military and aerospace use are regulated by SAE AS85049 within the USA.[24]

Hyperboloid contacts

To deliver ensured signal stability in extreme environments, traditional pin and socket design may become inadequate. Hyperboloid contacts are designed to withstand more extreme physical demands, such as vibration and shock.[20] They also require around 40% less insertion force[25] – as low as 0.3 newtons (1 ozf) per contact,[26] – which extends the lifespan, and in some cases offers an alternative to zero insertion force connectors.[27][25]

In a connector with hyperboloid contacts, each female contact has several equally spaced longitudinal wires twisted into a hyperbolic shape. These wires are highly resilient to strain, but still somewhat elastic, hence they essentially function as linear springs.[28][29] As the male pin is inserted, axial wires in the socket half are deflected, wrapping themselves around the pin to provide a number of contact points. The internal wires that form the hyperboloid structure are usually anchored at each end by bending the tip into a groove or notch in the housing.[30]

Whilst hyperboloid contacts may be the only option to make a reliable connection in some circumstances, they have the disadvantage of taking up greater volume in a connector, which can cause problems for high-density connectors.[25] They are also significantly more expensive than traditional pin and socket contacts, which has limited their uptake since their invention in the 1920s by Wilhelm Harold Frederick.[31] In the 1950s, Francois Bonhomme popularised hyperboloid contacts with his "Hypertac" connector, which was later acquired by Smiths Group. During the following decades, the connectors steadily gained popularity, and are still used for medical, industrial, military, aerospace, and rail applications (particularly trains in Europe).[28]

Pogo pins

 
Pogo pin connectors

Pogo pin or spring loaded connectors are commonly used in consumer and industrial products, where mechanical resilience and ease of use are priorities.[32] The connector consists of a barrel, a spring, and a plunger. They are in applications such as the MagSafe connector where a quick disconnect is desired for safety. Because they rely on spring pressure, not friction, they can be more durable and less damaging than traditional pin and socket design, leading to their use in in-circuit testing.[33]

Crown spring connectors

 
Typical crown spring plug and its female socket

Crown spring connectors are commonly used for higher current flows and industrial applications. They have a high number of contact points, which provides a more electrically reliable connection than traditional pin and socket connectors.[34]

Methods of connection

Plug and socket connectors
 
Male MIL-DTL-5015 plug
 
 
Male serial port connector
 
Mating surfaces of a hermaphroditic connector

Whilst technically inaccurate, electrical connectors can be viewed as a type of adapter to convert between two connection methods, which are permanently connected at one end and (usually) detachable at the other end.[7]: 40  By definition, each end of this "adapter" has a different connection method – e.g. the solder tabs on a male phone connector, and the male phone connector itself.[3] In this example, the solder tabs connected to the cable represent the permanent connection, whilst the male connector portion interfaces with a female socket forming a detachable connection.

There are many ways of applying a connector to a cable or device. Some of these methods can be accomplished without specialized tools. Other methods, while requiring a special tool, can assemble connectors much faster and more reliably, and make repairs easier.

The number of times a connector can connect and disconnect with its counterpart while meeting all its specifications is termed as mating cycles and is an indirect measure of connector lifespan. The material used for connector contact, plating type and thickness is a major factor that determines the mating cycles.[35]

Plug and socket connectors

Plug and socket connectors are usually made up of a male plug (typically pin contacts) and a female socket (typically receptacle contacts). Often, but not always, sockets are permanently fixed to a device as in a chassis connector (see above), and plugs are attached to a cable.

Plugs generally have one or more pins or prongs that are inserted into openings in the mating socket. The connection between the mating metal parts must be sufficiently tight to make a good electrical connection and complete the circuit. An alternative type of plug and socket connection uses hyperboloid contacts, which makes a more reliable electrical connection. When working with multi-pin connectors, it is helpful to have a pinout diagram to identify the wire or circuit node connected to each pin.

Some connector styles may combine pin and socket connection types in a single unit, referred to as a hermaphroditic connector.[6]: 56  These connectors includes mating with both male and female aspects, involving complementary paired identical parts each containing both protrusions and indentations. These mating surfaces are mounted into identical fittings that freely mate with any other, without regard for gender (provided that the size and type match).

Sometimes both ends of a cable are terminated with the same gender of connector, as in many Ethernet patch cables. In other applications the two ends are terminated differently, either with male and female of the same connector (as in an extension cord), or with incompatible connectors, which is sometimes called an adapter cable.

Plugs and sockets are widely used in various connector systems including blade connectors, breadboards, XLR connectors, car power outlets, banana connectors, and phone connectors.

Jacks and plugs

 

A jack is a connector that installs on the surface of a bulkhead or enclosure, and mates with its reciprocal, the plug.[36] According to the American Society of Mechanical Engineers,[37] the stationary (more fixed) connector of a pair is classified as a jack (denoted J), usually attached to a piece of equipment as in a chassis-mount or panel-mount connector. The movable (less fixed) connector is classified as a plug (denoted P),[37] designed to attach to a wire, cable or removable electrical assembly.[38] This convention is currently defined in ASME Y14.44-2008, which supersedes IEEE 200-1975, which in turn derives from the long-withdrawn MIL-STD-16 (from the 1950s), highlighting the heritage of this connector naming convention.[36] IEEE 315-1975 works alongside ASME Y14.44-2008 to define jacks and plugs.

The term jack occurs in several related terms:

  • The registered jack or modular jack in RJ11, RJ45 and other similar connectors used for telecommunication and computer networking
  • The telephone jack of manual telephone switchboards, which is the socket fitting the original 14 inch (6.35 mm) telephone plug
  • The 14 inch (6.35 mm) phone jack common to many electronic applications in various configurations, sometimes referred to as a headphone jack
  • The RCA jack, also known as a phono jack, common to consumer audiovisual electronics
  • The EIAJ jack for consumer appliances requiring a power supply of less than 18.0 volts

Crimp-on connectors

 
A wire and connector being crimped together with a crimping tool

Crimped connectors are a type of solderless connection, using mechanical friction and uniform deformation to secure a connector to a pre-stripped wire (usually stranded).[1] Crimping is used in splice connectors, crimped multipin plugs and sockets, and crimped coaxial connectors. Crimping usually requires a specialised crimping tool, but the connectors are quick and easy to install and are a common alternative to solder connections or insulation displacement connectors. Effective crimp connections deform the metal of the connector past its yield point so that the compressed wire causes tension in the surrounding connector, and these forces counter each other to create a high degree of static friction. Due to the elastic element in crimped connections, they are highly resistant to vibration and thermal shock.[39]

Crimped contacts are permanent (i.e. the connectors and wire ends cannot be reused).[40]

Crimped plug-and-socket connectors can be classified as rear release or front release. This relates to the side of the connector where the pins are anchored:[20]

  • Front release contacts are released from the front (contact side) of the connector, and removed from the rear. The removal tool engages with the front portion of the contact and pushes it through to the back of the connector.
  • Rear release contacts are released and removed from the rear (wire side) of the connector. The removal tool releases the contacts from the rear and pulls the contact out of the retainer.

Soldered connectors

Many plug and socket connectors are attached to a wire or cable by soldering conductors to electrodes on the back of the connector. Soldered joints in connectors are robust and reliable if executed correctly, but are usually slower to make than crimped connections.[1] When wires are to be soldered to the back of a connector, a backshell is often used to protect the connection and add strain relief. Metal solder buckets or solder cups are provided, which consist of a cylindrical cavity that an installer fills with solder before inserting the wire.[41]

When creating soldered connections, it is possible to melt the dielectric between pins or wires. This can cause problems because the thermal conductivity of metals causes heat to quickly distribute through the cable and connector, and when this heat melts plastic dielectric, it can cause short circuits or "flared" (conical) insulation.[40] Solder joints are also more prone to mechanical failure than crimped joints when subjected to vibration and compression.[42]

Insulation-displacement connectors

Since stripping insulation from wires is time-consuming, many connectors intended for rapid assembly use insulation-displacement connectors which cut the insulation as the wire is inserted.[1] These generally take the form of a fork-shaped opening in the terminal, into which the insulated wire is pressed, which cut through the insulation to contact the conductor. To make these connections reliably on a production line, special tools accurately control the forces applied during assembly. On small scales, these tools tend to cost more than tools for crimped connections.

Insulation displacement connectors are usually used with small conductors for signal purposes and at low voltage. Power conductors carrying more than a few amperes are more reliably terminated with other means, though "hot tap" press-on connectors find some use in automotive applications for additions to existing wiring.

A common example is the multi-conductor flat ribbon cable used in computer disk drives; to terminate each of the many (approximately 40) wires individually would be slow and error-prone, but an insulation displacement connector can terminate all the wires in a single action. Another very common use is so-called punch-down blocks used for terminating unshielded twisted pair wiring.

 
Binding posts on a bi-amplified loudspeaker

Binding posts

Binding posts are a single-wire connection method, where stripped wire is screwed or clamped to a metal electrode. Such connectors are frequently used in electronic test equipment and audio. Many binding posts also accept a banana plug.

Screw terminals

Screw connections are frequently used for semi-permanent wiring and connections inside devices, due to their simple but reliable construction. The basic principle of all screw terminals involves the tip of a bolt clamping onto a stripped conductor. They can be used to join multiple conductors,[43] to connect wires to a printed circuit board, or to terminate a cable into a plug or socket.[7]: 50  The clamping screw may act in the longitudinal axis (parallel to the wire) or the transverse axis (perpendicular to the wire), or both. Some disadvantages are that connecting wires is more difficult than simply plugging in a cable, and screw terminals are generally not very well protected from contact with persons or foreign conducting materials.

 
Terminal blocks of various types

Terminal blocks (also called terminal boards or strips) provide a convenient means of connecting individual electrical wires without a splice or physically joining the ends. Since terminal blocks are readily available for a wide range of wire sizes and terminal quantity, they are one of the most flexible types of electrical connector available. One type of terminal block accepts wires that are prepared only by stripping a short length of insulation from the end. Another type, often called barrier strips, accepts wires that have ring or spade terminal lugs crimped onto the wires.

Printed circuit board (PCB) mounted screw terminals let individual wires connect to a PCB through leads soldered to the board.

Ring and spade connectors

 
Ring style wire-end crimp connectors

The connectors in the top row of the image are known as ring terminals and spade terminals (sometimes called fork or split ring terminals). Electrical contact is made by the flat surface of the ring or spade, while mechanically they are attached by passing a screw or bolt through them. The spade terminal form factor facilitates connections since the screw or bolt can be left partially screwed in as the spade terminal is removed or attached. Their sizes can be determined by the gauge of the conducting wire, and the interior and exterior diameters.

In the case of insulated crimp connectors, the crimped area lies under an insulating sleeve through which the pressing force acts. During crimping, the extended end of this insulating sleeve is simultaneously pressed around the insulated area of the cable, creating strain relief. The insulating sleeve of insulated connectors has a color that indicates the wire's cross-section area. Colors are standardized according to DIN 46245:

  • Red for cross-section areas from 0.5 to 1 mm²
  • Blue for cross-section areas from 1.5 to 2.5 mm²
  • Yellow for cross-section areas over 4 to 6 mm²

Blade connectors

 
Blade connectors (lower half of photo). Ring and spade terminals (upper half). Bullet terminals, male and female (right-center, with blue wires)

A blade connector is a type of single wire, plug-and-socket connection device using a flat conductive blade (plug) that is inserted into a receptacle. Wires are typically attached to male or female blade connector terminals by either crimping or soldering. Insulated and uninsulated varieties are available. In some cases the blade is an integral manufactured part of a component (such as a switch or a speaker unit), and the reciprocal connector terminal is pushed onto the device's connector terminal.

Other connection methods


See also

Connectors

References

  1. ^ a b c d e f g "Electrical Connectors Information". Engineering360. IEEE GlobalSpec. Retrieved 30 June 2019.
  2. ^ Mroczkowski, Robert S. (1998). "Ch 1". Electrical Connector Handbook: Theory and Applications. McGraw Hill. ISBN 0-07-041401-7.
  3. ^ a b Elliott, Brian S. (2007). "Chapter 9: Connectors". Electromechanical Devices & Components (2nd ed.). McGraw-Hill Professional. ISBN 978-0-07-147752-9.
  4. ^ SFUptownMaker. "Connector Basics". SparkFun. Retrieved 30 June 2019.
  5. ^ David, Larry (17 March 2012). "Engineering Definitions – 'Com' to 'Con'". Electronic Engineering Dictionary Terms. Connector. Retrieved 30 June 2019.
  6. ^ a b Horowitz, Paul; Hill, Winfield (1989). The Art of Electronics (2nd ed.). Cambridge University Press. ISBN 0-521-37095-7.
  7. ^ a b c d e f Connectors – Technologies and Trends (PDF). ZVEI – German Electrical and Electronic Manufacturers’ Association. August 2016.
  8. ^ a b "Molex Connectors Explained, as used in Pinball". Marvin's Marvelous Mechanical Museum. 4 March 2005. Retrieved 1 July 2019.
  9. ^ Endres, Herbert (19 December 2011). "Gold or Tin versus Gold and Tin?". Molex. Retrieved 1 July 2019.
  10. ^ AMP Incorporated (29 July 1996). (PDF). Tyco Electronic Corporation. Archived from the original (PDF) on 29 March 2018. Retrieved 1 July 2019. Gold is generally specified as a contact coating for low level signal voltage and current applications, and where high reliability is a major consideration
  11. ^ a b c "Connectors: Failure Mechanisms and Anomalies" (PDF). Naval Sea Systems Command. Retrieved 1 July 2019.
  12. ^ Normalized failure mode distributions were originally compiled from a combination of: MIL-HDBK-978, “NASA Parts Application Handbook”, 1991; MIL-HDBK-338, “Electronic Reliability Design Handbook”, 1994; “Reliability Toolkit: Commercial Practices Edition", Reliability Analysis Center (RAC), 1998; and “Failure Mode, Effects, and Criticality Analysis (FMECA)”, RAC, 1993.
  13. ^ "Ribbon Cable Interconnect Solutions" (PDF). TE Connectivity. April 2012. p. 30. Retrieved 1 July 2019. By its design the traditional failure mode in tin plated connections, fretting corrosion, is prevented.
  14. ^ Mroczkowski, Dr. Robert S. (15 October 2004). "A Perspective on Connector Reliability" (PDF). IEEE. connNtext. Retrieved 1 July 2019.
  15. ^ a b "Essential Connector Terms and Definitions for Specifiers of Interconnect Wiring Systems" (PDF). Glenair, Inc. 2004. Retrieved 2019-06-25.
  16. ^ "Field Guide: Industrial Ethernet Connectivity". 2017.
  17. ^ Dietmar Röring. "M12 versus RJ45 Ethernet connection systems". 2014.
  18. ^ a b "Backshells by Amphenol Socapex" (PDF). RS Components Ltd. Amphenol Socapex. 2 November 2016. Retrieved 26 June 2019.
  19. ^ "Hybrid connector". Telecommunications: Glossary of Telecommunication Terms (FS1037C). National Telecommunications and Information Administration. 23 August 1996.
  20. ^ a b c Worley, Jon (31 July 2018). "Circular Connector Terminology Guide". NYK Component Solutions. Retrieved 2018-10-15.
  21. ^ Evans, Bill (2011). Live sound fundamentals. Course Technology. pp. 24, 29. ISBN 978-1-4354-5494-1.
  22. ^ "How to Select the Proper Backshell" (PDF). CDM Electronics. 12 June 2012. Retrieved 26 June 2019.
  23. ^ David, Larry (17 March 2012). "Back Shell Definition". Electronic Engineering Dictionary Terms. Retrieved 30 June 2019.
  24. ^ "How to select a backshell" (PDF). Amphenol Corporation. BackShellWorld.com. 6 September 2008. Retrieved 26 June 2019.
  25. ^ a b c Lascelles, Robert (8 June 2015). "Modern Hyperboloid Contacts for Circular I/O Connectors". ConnectorSupplier.com. Retrieved 27 June 2019.
  26. ^ "IEH Hyperboloid Connectors" (PDF). IEH Corporation. October 2017. Retrieved 27 June 2019.
  27. ^ "Our Technology". IEH Corporation. Retrieved 26 June 2019.
  28. ^ a b David Brearley (9 October 2015). "Would you trust your life to a 50-year old connector design?". Connector Tips. Retrieved 27 June 2019.
  29. ^ SU application 1125684A1, Pustynskij Nikolaj, "Hyperboloid-shaped socket for connection device", published 1983 .
  30. ^ GB application 2366097A, Donald Richard Lacoy, "Hyperboloid electrical socket", published 27 February 2002 .
  31. ^ US patent 1833145A, Wilhelm Harold Frederick, "Connecter", published 7 July 1925 .
  32. ^ "Basic Pogo Pin Intro". C.C.P. Contact Probes Co. Retrieved 3 July 2019.
  33. ^ "Welcome to Qualmax". Qualmax. Retrieved 3 July 2019.
  34. ^ Slade, Paul G. (2014). Electrical Contacts: Principles and Applications (2nd ed.). CRC Press. p. 408. ISBN 978-1-4398-8130-9.
  35. ^ "Learn More about Connector Mating Cycles". www.amphenol-icc.com. Retrieved 2021-08-23.
  36. ^ a b Huggins, John S. (15 July 2009). "Jack/Plug – Jack, Plug, Male, Female Connectors". An Engineer's Review. Retrieved 1 July 2019.
  37. ^ a b . ASME, Fairfield, NJ. 2008. Archived from the original on 2010-03-13. Retrieved 2012-02-03. the stationary (more fixed) connector of a mating pair shall be designated J or X ... The movable (less fixed) connector of a mating pair shall be designated P
  38. ^ Graphic Symbols for Electrical and Electronics Diagrams (Including Reference Designation Letters): IEEE-315-1975 (Reaffirmed 1993): Section 22. IEEE and ANSI, New York, NY. 1993.
  39. ^ "Crimp vs Solder: Pros and Cons". RF Connectors. 1 December 2004. Retrieved 1 July 2019.
  40. ^ a b "Crimp vs. Solder" (PDF). Aviel Electronics Catalog. 2013. Retrieved 1 July 2019.
  41. ^ "Field Installable: The secret to mastering connectors". Design Spark. RS Components. 16 March 2017. Solder connectors. Retrieved 1 July 2019.
  42. ^ Simon, Andre. "Solder Vs Crimping". High Performance Academy. Retrieved 1 July 2019.
  43. ^ "Datasheet 563: Cable Connector" (PDF). Clipsal. Retrieved 1 July 2019.
General
  • Foreman, Chris, "Sound System Design", Handbook for Sound Engineers, Third Edition, Glen M. Ballou, Ed., Elsevier Inc., 2002, pp. 1171–72.

External links

  Media related to Electrical connectors at Wikimedia Commons

electrical, connector, components, electrical, circuit, electrically, connected, electric, current, between, them, through, electrical, conductor, electrical, connector, electromechanical, device, used, create, electrical, connection, between, parts, electrica. Components of an electrical circuit are electrically connected if an electric current can run between them through an electrical conductor An electrical connector is an electromechanical device used to create an electrical connection between parts of an electrical circuit or between different electrical circuits thereby joining them into a larger circuit 1 Most electrical connectors have a gender i e the male component called a plug connects to the female component or socket The connection may be removable as for portable equipment require a tool for assembly and removal or serve as a permanent electrical joint between two points 2 An adapter can be used to join dissimilar connectors Schematic symbols for male and female connectors see Gender of connectors and fasteners This rear panel of an integrated amplifier features a variety of electrical connectors Connectors on the back of a 2018 computer Thousands of configurations of connectors are manufactured for power data and audiovisual applications 3 Electrical connectors can be divided into four basic categories differentiated by their function 4 inline or cable connectors permanently attached to a cable so it can be plugged into another terminal either a stationary instrument or another cable 5 Chassis or panel connectors permanently attached to a piece of equipment so users can connect a cable to a stationary device PCB mount connectors soldered to a printed circuit board providing a point for cable or wire attachment 6 56 e g pin headers screw terminals board to board connectors Splice or butt connectors primarily insulation displacement connectors that permanently join two lengths of wire or cableIn computing electrical connectors are considered a physical interface and constitute part of the physical layer in the OSI model of networking Contents 1 Physical construction 1 1 Materials 1 2 Failure modes 1 3 Circular connectors 1 4 Hybrid connectors 2 Mechanical features 2 1 Pin sequence 2 2 Keying 2 3 Locking mechanisms 2 4 Backshells 2 5 Hyperboloid contacts 2 6 Pogo pins 2 7 Crown spring connectors 3 Methods of connection 3 1 Plug and socket connectors 3 1 1 Jacks and plugs 3 2 Crimp on connectors 3 3 Soldered connectors 3 4 Insulation displacement connectors 3 5 Binding posts 3 6 Screw terminals 3 7 Ring and spade connectors 3 8 Blade connectors 3 9 Other connection methods 4 See also 4 1 Connectors 5 References 6 External linksPhysical construction EditIn addition to the classes mentioned above connectors are characterised by their pinout method of connection materials size contact resistance insulation mechanical durability ingress protection lifetime number of cycles and ease of use It is usually desirable for a connector to be easy to identify visually rapid to assemble inexpensive and require only simple tooling In some cases an equipment manufacturer might choose a connector specifically because it is not compatible with those from other sources allowing control of what may be connected No single connector has all the ideal properties for every application the proliferation of types is a result of the diverse yet specific requirements of manufacturers 7 6 Materials Edit Electrical connectors essentially consist of two classes of materials conductors and insulators Properties important to conductor materials are contact resistance conductivity mechanical strength formability and resilience 8 Insulators must have a high electrical resistance withstand high temperatures and be easy to manufacture for a precise fit Electrodes in connectors are usually made of copper alloys due to their good conductivity and malleability 7 15 Alternatives include brass phosphor bronze and beryllium copper The base electrode metal is often coated with another inert metal such as gold nickel or tin 8 The use of a coating material with good conductivity mechanical robustness and corrosion resistance helps to reduce the influence of passivating oxide layers and surface adsorbates which limit metal to metal contact patches and contribute to contact resistance For example copper alloys have favorable mechanical properties for electrodes but are hard to solder and prone to corrosion Thus copper pins are usually coated with gold to alleviate these pitfalls especially for analog signals and high reliability applications 9 10 Contact carriers that hold the parts of a connector together are usually made of plastic due to its insulating properties Housings or backshells can be made of molded plastic and metal 7 15 Connector bodies for high temperature use such as thermocouples or associated with large incandescent lamps may be made of fired ceramic material Failure modes Edit The majority of connector failures result in intermittent connections or open contacts 11 12 Failure mode Relative probabilityOpen circuit 61 Poor contact 23 Short circuit 16 Connectors are purely passive components that is they do not enhance the function of a circuit so connectors should affect the function of a circuit as little as possible Insecure mounting of connectors primarily chassis mounted can contribute significantly to the risk of failure especially when subjected to extreme shock or vibration 11 Other causes of failure are connectors inadequately rated for the applied current and voltage connectors with inadequate ingress protection and threaded backshells that are worn or damaged High temperatures can also cause failure in connectors resulting in an avalanche of failures ambient temperature increases leading to a decrease in insulation resistance and increase in conductor resistance this increase generates more heat and the cycle repeats 11 Fretting so called dynamic corrosion is a common failure mode in electrical connectors that have not been specifically designed to prevent it especially in those that are frequently mated and de mated 13 Surface corrosion is a risk for many metal parts in connectors and can cause contacts to form a thin surface layer that increases resistance thus contributing to heat buildup and intermittent connections 14 However remating or reseating a connector can alleviate the issue of surface corrosion since each cycle scrapes a microscopic layer off the surface of the contact s exposing a fresh unoxidised surface Circular connectors Edit Many connectors used for industrial and high reliability applications are circular in cross section with a cylindrical housing and circular contact interface geometries This is in contrast to the rectangular design of some connectors e g USB or blade connectors They are commonly used for easier engagement and disengagement tight environmental sealing and rugged mechanical performance 15 They are widely used in military aerospace industrial machinery and rail where MIL DTL 5015 and MIL DTL 38999 are commonly specified Fields such as sound engineering and radio communication also use circular connectors such as XLR and BNC AC power plugs are also commonly circular for example Schuko plugs and IEC 60309 NMEA 2000 cabling using M12 connectors The M12 connector specified in IEC 61076 2 101 is a circular electrical plug receptacle pair with 12mm OD mating threads used in NMEA 2000 DeviceNet IO Link some kinds of Industrial Ethernet etc 16 17 A disadvantage of the circular design is its inefficient use of panel space when used in arrays when compared to rectangular connectors Circular connectors commonly use backshells which provide physical and electromagnetic protection whilst sometimes also providing a method for locking the connector into a receptacle 18 In some cases this backshell provides a hermetic seal or some degree of ingress protection through the use of grommets O rings or potting 15 Hybrid connectors Edit Hybrid connectors allow the intermixing of many connector types usually by way of a housing with inserts 19 These housings may also allow intermixing of electrical and non electrical interfaces examples of the latter being pneumatic line connectors and optical fiber connectors Because hybrid connectors are modular in nature they tend to simplify assembly repair and future modifications They also allow the creation of composite cable assemblies that can reduce equipment installation time by reducing the number of individual cable and connector assemblies Mechanical features EditPin sequence Edit Some connectors are designed such that certain pins make contact before others when inserted and break first on disconnection 1 This is often used in power connectors to protect equipment e g connecting safety ground first It is also employed for digital signals as a method to sequence connections properly in hot swapping Keying Edit Examples of keyed connectors XLR connector showing the notch for alignment A 4 pin Mini DIN S Video cable with notches and a rectangular alignment pin Many connectors are keyed with some mechanical component sometimes called a keyway which prevents mating in an incorrect orientation 20 This can be used to prevent mechanical damage to connectors from being jammed in at the wrong angle or into the wrong connector or to prevent incompatible or dangerous electrical connections such as plugging an audio cable into a power outlet 1 Keying also prevents otherwise symmetrical connectors from being connected in the wrong orientation or polarity Keying is particularly important for situations where there are many similar connectors such as in signal electronics 7 26 For instance XLR connectors have a notch to ensure proper orientation while Mini DIN plugs have a plastic projection that fits into a corresponding hole in the socket they also have a notched metal skirt to provide secondary keying 21 Locking mechanisms Edit Some connector housings are designed with locking mechanisms to prevent inadvertent disconnection or poor environmental sealing 1 Locking mechanism designs include locking levers of various sorts jackscrews screw in shells push pull connector and toggle or bayonet systems Some connectors particularly those with large numbers of contacts require high forces to connect and disconnect Locking levers and jackscrews and screw in shells for such connectors frequently serve both to retain the connector when connected and to provide the force needed for connection and disconnection Depending on application requirements housings with locking mechanisms may be tested under various environmental simulations that include physical shock and vibration water spray dust etc to ensure the integrity of the electrical connection and housing seals Backshells Edit Backshells are a common accessory for industrial and high reliability connectors especially circular connectors 18 Backshells typically protect the connector and or cable from environmental or mechanical stress or shield it from electromagnetic interference 22 Many types of backshells are available for different purposes including various sizes shapes materials and levels of protection Backshells usually lock onto the cable with a clamp or moulded boot and may be threaded for attachment to a mating receptacle 23 Backshells for military and aerospace use are regulated by SAE AS85049 within the USA 24 Hyperboloid contacts Edit To deliver ensured signal stability in extreme environments traditional pin and socket design may become inadequate Hyperboloid contacts are designed to withstand more extreme physical demands such as vibration and shock 20 They also require around 40 less insertion force 25 as low as 0 3 newtons 1 ozf per contact 26 which extends the lifespan and in some cases offers an alternative to zero insertion force connectors 27 25 In a connector with hyperboloid contacts each female contact has several equally spaced longitudinal wires twisted into a hyperbolic shape These wires are highly resilient to strain but still somewhat elastic hence they essentially function as linear springs 28 29 As the male pin is inserted axial wires in the socket half are deflected wrapping themselves around the pin to provide a number of contact points The internal wires that form the hyperboloid structure are usually anchored at each end by bending the tip into a groove or notch in the housing 30 Whilst hyperboloid contacts may be the only option to make a reliable connection in some circumstances they have the disadvantage of taking up greater volume in a connector which can cause problems for high density connectors 25 They are also significantly more expensive than traditional pin and socket contacts which has limited their uptake since their invention in the 1920s by Wilhelm Harold Frederick 31 In the 1950s Francois Bonhomme popularised hyperboloid contacts with his Hypertac connector which was later acquired by Smiths Group During the following decades the connectors steadily gained popularity and are still used for medical industrial military aerospace and rail applications particularly trains in Europe 28 Pogo pins Edit Main article Pogo pin Pogo pin connectors Pogo pin or spring loaded connectors are commonly used in consumer and industrial products where mechanical resilience and ease of use are priorities 32 The connector consists of a barrel a spring and a plunger They are in applications such as the MagSafe connector where a quick disconnect is desired for safety Because they rely on spring pressure not friction they can be more durable and less damaging than traditional pin and socket design leading to their use in in circuit testing 33 Crown spring connectors Edit Typical crown spring plug and its female socket Crown spring connectors are commonly used for higher current flows and industrial applications They have a high number of contact points which provides a more electrically reliable connection than traditional pin and socket connectors 34 Methods of connection EditPlug and socket connectors Male MIL DTL 5015 plug Female VGA connector Male serial port connector Mating surfaces of a hermaphroditic connector Whilst technically inaccurate electrical connectors can be viewed as a type of adapter to convert between two connection methods which are permanently connected at one end and usually detachable at the other end 7 40 By definition each end of this adapter has a different connection method e g the solder tabs on a male phone connector and the male phone connector itself 3 In this example the solder tabs connected to the cable represent the permanent connection whilst the male connector portion interfaces with a female socket forming a detachable connection There are many ways of applying a connector to a cable or device Some of these methods can be accomplished without specialized tools Other methods while requiring a special tool can assemble connectors much faster and more reliably and make repairs easier The number of times a connector can connect and disconnect with its counterpart while meeting all its specifications is termed as mating cycles and is an indirect measure of connector lifespan The material used for connector contact plating type and thickness is a major factor that determines the mating cycles 35 Plug and socket connectors Edit See also Gender of connectors and fasteners and Pinout Plug and socket connectors are usually made up of a male plug typically pin contacts and a female socket typically receptacle contacts Often but not always sockets are permanently fixed to a device as in a chassis connector see above and plugs are attached to a cable Plugs generally have one or more pins or prongs that are inserted into openings in the mating socket The connection between the mating metal parts must be sufficiently tight to make a good electrical connection and complete the circuit An alternative type of plug and socket connection uses hyperboloid contacts which makes a more reliable electrical connection When working with multi pin connectors it is helpful to have a pinout diagram to identify the wire or circuit node connected to each pin Some connector styles may combine pin and socket connection types in a single unit referred to as a hermaphroditic connector 6 56 These connectors includes mating with both male and female aspects involving complementary paired identical parts each containing both protrusions and indentations These mating surfaces are mounted into identical fittings that freely mate with any other without regard for gender provided that the size and type match Sometimes both ends of a cable are terminated with the same gender of connector as in many Ethernet patch cables In other applications the two ends are terminated differently either with male and female of the same connector as in an extension cord or with incompatible connectors which is sometimes called an adapter cable Plugs and sockets are widely used in various connector systems including blade connectors breadboards XLR connectors car power outlets banana connectors and phone connectors Jacks and plugs Edit Male phone plug A jack is a connector that installs on the surface of a bulkhead or enclosure and mates with its reciprocal the plug 36 According to the American Society of Mechanical Engineers 37 the stationary more fixed connector of a pair is classified as a jack denoted J usually attached to a piece of equipment as in a chassis mount or panel mount connector The movable less fixed connector is classified as a plug denoted P 37 designed to attach to a wire cable or removable electrical assembly 38 This convention is currently defined in ASME Y14 44 2008 which supersedes IEEE 200 1975 which in turn derives from the long withdrawn MIL STD 16 from the 1950s highlighting the heritage of this connector naming convention 36 IEEE 315 1975 works alongside ASME Y14 44 2008 to define jacks and plugs The term jack occurs in several related terms The registered jack or modular jack in RJ11 RJ45 and other similar connectors used for telecommunication and computer networking The telephone jack of manual telephone switchboards which is the socket fitting the original 1 4 inch 6 35 mm telephone plug The 1 4 inch 6 35 mm phone jack common to many electronic applications in various configurations sometimes referred to as a headphone jack The RCA jack also known as a phono jack common to consumer audiovisual electronics The EIAJ jack for consumer appliances requiring a power supply of less than 18 0 voltsCrimp on connectors Edit A wire and connector being crimped together with a crimping tool Main article Crimp electrical Crimped connectors are a type of solderless connection using mechanical friction and uniform deformation to secure a connector to a pre stripped wire usually stranded 1 Crimping is used in splice connectors crimped multipin plugs and sockets and crimped coaxial connectors Crimping usually requires a specialised crimping tool but the connectors are quick and easy to install and are a common alternative to solder connections or insulation displacement connectors Effective crimp connections deform the metal of the connector past its yield point so that the compressed wire causes tension in the surrounding connector and these forces counter each other to create a high degree of static friction Due to the elastic element in crimped connections they are highly resistant to vibration and thermal shock 39 Crimped contacts are permanent i e the connectors and wire ends cannot be reused 40 Crimped plug and socket connectors can be classified as rear release or front release This relates to the side of the connector where the pins are anchored 20 Front release contacts are released from the front contact side of the connector and removed from the rear The removal tool engages with the front portion of the contact and pushes it through to the back of the connector Rear release contacts are released and removed from the rear wire side of the connector The removal tool releases the contacts from the rear and pulls the contact out of the retainer Soldered connectors Edit See also Soldering Many plug and socket connectors are attached to a wire or cable by soldering conductors to electrodes on the back of the connector Soldered joints in connectors are robust and reliable if executed correctly but are usually slower to make than crimped connections 1 When wires are to be soldered to the back of a connector a backshell is often used to protect the connection and add strain relief Metal solder buckets or solder cups are provided which consist of a cylindrical cavity that an installer fills with solder before inserting the wire 41 When creating soldered connections it is possible to melt the dielectric between pins or wires This can cause problems because the thermal conductivity of metals causes heat to quickly distribute through the cable and connector and when this heat melts plastic dielectric it can cause short circuits or flared conical insulation 40 Solder joints are also more prone to mechanical failure than crimped joints when subjected to vibration and compression 42 Insulation displacement connectors Edit Main article Insulation displacement connector Since stripping insulation from wires is time consuming many connectors intended for rapid assembly use insulation displacement connectors which cut the insulation as the wire is inserted 1 These generally take the form of a fork shaped opening in the terminal into which the insulated wire is pressed which cut through the insulation to contact the conductor To make these connections reliably on a production line special tools accurately control the forces applied during assembly On small scales these tools tend to cost more than tools for crimped connections Insulation displacement connectors are usually used with small conductors for signal purposes and at low voltage Power conductors carrying more than a few amperes are more reliably terminated with other means though hot tap press on connectors find some use in automotive applications for additions to existing wiring A common example is the multi conductor flat ribbon cable used in computer disk drives to terminate each of the many approximately 40 wires individually would be slow and error prone but an insulation displacement connector can terminate all the wires in a single action Another very common use is so called punch down blocks used for terminating unshielded twisted pair wiring Binding posts on a bi amplified loudspeaker Binding posts Edit Main article Binding post Binding posts are a single wire connection method where stripped wire is screwed or clamped to a metal electrode Such connectors are frequently used in electronic test equipment and audio Many binding posts also accept a banana plug Screw terminals Edit Main article Screw terminal Screw connections are frequently used for semi permanent wiring and connections inside devices due to their simple but reliable construction The basic principle of all screw terminals involves the tip of a bolt clamping onto a stripped conductor They can be used to join multiple conductors 43 to connect wires to a printed circuit board or to terminate a cable into a plug or socket 7 50 The clamping screw may act in the longitudinal axis parallel to the wire or the transverse axis perpendicular to the wire or both Some disadvantages are that connecting wires is more difficult than simply plugging in a cable and screw terminals are generally not very well protected from contact with persons or foreign conducting materials Terminal blocks of various types Terminal blocks also called terminal boards or strips provide a convenient means of connecting individual electrical wires without a splice or physically joining the ends Since terminal blocks are readily available for a wide range of wire sizes and terminal quantity they are one of the most flexible types of electrical connector available One type of terminal block accepts wires that are prepared only by stripping a short length of insulation from the end Another type often called barrier strips accepts wires that have ring or spade terminal lugs crimped onto the wires Printed circuit board PCB mounted screw terminals let individual wires connect to a PCB through leads soldered to the board Ring and spade connectors Edit Ring style wire end crimp connectors The connectors in the top row of the image are known as ring terminals and spade terminals sometimes called fork or split ring terminals Electrical contact is made by the flat surface of the ring or spade while mechanically they are attached by passing a screw or bolt through them The spade terminal form factor facilitates connections since the screw or bolt can be left partially screwed in as the spade terminal is removed or attached Their sizes can be determined by the gauge of the conducting wire and the interior and exterior diameters In the case of insulated crimp connectors the crimped area lies under an insulating sleeve through which the pressing force acts During crimping the extended end of this insulating sleeve is simultaneously pressed around the insulated area of the cable creating strain relief The insulating sleeve of insulated connectors has a color that indicates the wire s cross section area Colors are standardized according to DIN 46245 Red for cross section areas from 0 5 to 1 mm Blue for cross section areas from 1 5 to 2 5 mm Yellow for cross section areas over 4 to 6 mm Blade connectors Edit Blade connectors lower half of photo Ring and spade terminals upper half Bullet terminals male and female right center with blue wires A blade connector is a type of single wire plug and socket connection device using a flat conductive blade plug that is inserted into a receptacle Wires are typically attached to male or female blade connector terminals by either crimping or soldering Insulated and uninsulated varieties are available In some cases the blade is an integral manufactured part of a component such as a switch or a speaker unit and the reciprocal connector terminal is pushed onto the device s connector terminal Other connection methods Edit Crocodile alligator clips conductive clamps used for temporary connections e g jumper cables Board to board connectors e g card edge connectors or FPGA mezzanine connectors Twist on wire connectors e g wire nuts used in low voltage power circuits for wires up to about 10 AWG Wire wrapping used in older circuit boardsSee also EditAdapter Bent pin analysis Cable gland Electrical contacts Electrical network Electrical splice Electrical termination Gender of connectors and fasteners InCa3D Lightbulb socket Pothead for a termination on a high voltage electric power cable Tee connector Tube socket Wire nut Connectors Edit AC power plugs and sockets Audio and video connector Banana connector Battery holder Battery terminals Coaxial power connector Computer port hardware Crocodile clip DC connector DIN connector Dock connector D sub connectors Edge connector Elastomeric connector IEC appliance couplers IEC 60320 JST connector Mini DIN connector Optical fiber connector Phone connector audio Pin header RCA connector RJ XX connector Flexible electronicsReferences Edit a b c d e f g Electrical Connectors Information Engineering360 IEEE GlobalSpec Retrieved 30 June 2019 Mroczkowski Robert S 1998 Ch 1 Electrical Connector Handbook Theory and Applications McGraw Hill ISBN 0 07 041401 7 a b Elliott Brian S 2007 Chapter 9 Connectors Electromechanical Devices amp Components 2nd ed McGraw Hill Professional ISBN 978 0 07 147752 9 SFUptownMaker Connector Basics SparkFun Retrieved 30 June 2019 David Larry 17 March 2012 Engineering Definitions Com to Con Electronic Engineering Dictionary Terms Connector Retrieved 30 June 2019 a b Horowitz Paul Hill Winfield 1989 The Art of Electronics 2nd ed Cambridge University Press ISBN 0 521 37095 7 a b c d e f Connectors Technologies and Trends PDF ZVEI German Electrical and Electronic Manufacturers Association August 2016 a b Molex Connectors Explained as used in Pinball Marvin s Marvelous Mechanical Museum 4 March 2005 Retrieved 1 July 2019 Endres Herbert 19 December 2011 Gold or Tin versus Gold and Tin Molex Retrieved 1 July 2019 AMP Incorporated 29 July 1996 Golden Rules Guidelines For The Use Of Gold On Connector Contacts PDF Tyco Electronic Corporation Archived from the original PDF on 29 March 2018 Retrieved 1 July 2019 Gold is generally specified as a contact coating for low level signal voltage and current applications and where high reliability is a major consideration a b c Connectors Failure Mechanisms and Anomalies PDF Naval Sea Systems Command Retrieved 1 July 2019 Normalized failure mode distributions were originally compiled from a combination of MIL HDBK 978 NASA Parts Application Handbook 1991 MIL HDBK 338 Electronic Reliability Design Handbook 1994 Reliability Toolkit Commercial Practices Edition Reliability Analysis Center RAC 1998 and Failure Mode Effects and Criticality Analysis FMECA RAC 1993 Ribbon Cable Interconnect Solutions PDF TE Connectivity April 2012 p 30 Retrieved 1 July 2019 By its design the traditional failure mode in tin plated connections fretting corrosion is prevented Mroczkowski Dr Robert S 15 October 2004 A Perspective on Connector Reliability PDF IEEE connNtext Retrieved 1 July 2019 a b Essential Connector Terms and Definitions for Specifiers of Interconnect Wiring Systems PDF Glenair Inc 2004 Retrieved 2019 06 25 Field Guide Industrial Ethernet Connectivity 2017 Dietmar Roring M12 versus RJ45 Ethernet connection systems 2014 a b Backshells by Amphenol Socapex PDF RS Components Ltd Amphenol Socapex 2 November 2016 Retrieved 26 June 2019 Hybrid connector Telecommunications Glossary of Telecommunication Terms FS1037C National Telecommunications and Information Administration 23 August 1996 a b c Worley Jon 31 July 2018 Circular Connector Terminology Guide NYK Component Solutions Retrieved 2018 10 15 Evans Bill 2011 Live sound fundamentals Course Technology pp 24 29 ISBN 978 1 4354 5494 1 How to Select the Proper Backshell PDF CDM Electronics 12 June 2012 Retrieved 26 June 2019 David Larry 17 March 2012 Back Shell Definition Electronic Engineering Dictionary Terms Retrieved 30 June 2019 How to select a backshell PDF Amphenol Corporation BackShellWorld com 6 September 2008 Retrieved 26 June 2019 a b c Lascelles Robert 8 June 2015 Modern Hyperboloid Contacts for Circular I O Connectors ConnectorSupplier com Retrieved 27 June 2019 IEH Hyperboloid Connectors PDF IEH Corporation October 2017 Retrieved 27 June 2019 Our Technology IEH Corporation Retrieved 26 June 2019 a b David Brearley 9 October 2015 Would you trust your life to a 50 year old connector design Connector Tips Retrieved 27 June 2019 SU application 1125684A1 Pustynskij Nikolaj Hyperboloid shaped socket for connection device published 1983 GB application 2366097A Donald Richard Lacoy Hyperboloid electrical socket published 27 February 2002 US patent 1833145A Wilhelm Harold Frederick Connecter published 7 July 1925 Basic Pogo Pin Intro C C P Contact Probes Co Retrieved 3 July 2019 Welcome to Qualmax Qualmax Retrieved 3 July 2019 Slade Paul G 2014 Electrical Contacts Principles and Applications 2nd ed CRC Press p 408 ISBN 978 1 4398 8130 9 Learn More about Connector Mating Cycles www amphenol icc com Retrieved 2021 08 23 a b Huggins John S 15 July 2009 Jack Plug Jack Plug Male Female Connectors An Engineer s Review Retrieved 1 July 2019 a b Reference Designations for Electrical and Electronics Parts and Equipment ASME Y14 44 2008 Section 2 1 5 3 2 ASME Fairfield NJ 2008 Archived from the original on 2010 03 13 Retrieved 2012 02 03 the stationary more fixed connector of a mating pair shall be designated J or X The movable less fixed connector of a mating pair shall be designated P Graphic Symbols for Electrical and Electronics Diagrams Including Reference Designation Letters IEEE 315 1975 Reaffirmed 1993 Section 22 IEEE and ANSI New York NY 1993 Crimp vs Solder Pros and Cons RF Connectors 1 December 2004 Retrieved 1 July 2019 a b Crimp vs Solder PDF Aviel Electronics Catalog 2013 Retrieved 1 July 2019 Field Installable The secret to mastering connectors Design Spark RS Components 16 March 2017 Solder connectors Retrieved 1 July 2019 Simon Andre Solder Vs Crimping High Performance Academy Retrieved 1 July 2019 Datasheet 563 Cable Connector PDF Clipsal Retrieved 1 July 2019 GeneralForeman Chris Sound System Design Handbook for Sound Engineers Third Edition Glen M Ballou Ed Elsevier Inc 2002 pp 1171 72 External links Edit Media related to Electrical connectors at Wikimedia Commons Retrieved from https en wikipedia org w index php title Electrical connector amp oldid 1125451284, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.