Standard RAID levels

In computer storage, the standard RAID levels comprise a basic set of RAID ("redundant array of independent disks" or "redundant array of inexpensive disks") configurations that employ the techniques of striping, mirroring, or parity to create large reliable data stores from multiple general-purpose computer hard disk drives (HDDs). The most common types are RAID 0 (striping), RAID 1 (mirroring) and its variants, RAID 5 (distributed parity), and RAID 6 (dual parity). Multiple RAID levels can also be combined or nested, for instance RAID 10 (striping of mirrors) or RAID 01 (mirroring stripe sets). RAID levels and their associated data formats are standardized by the Storage Networking Industry Association (SNIA) in the Common RAID Disk Drive Format (DDF) standard.[1] The numerical values only serve as identifiers and do not signify performance, reliability, generation, or any other metric.

While most RAID levels can provide good protection against and recovery from hardware defects or defective sectors/read errors (hard errors), they do not provide any protection against data loss due to catastrophic failures (fire, water) or soft errors such as user error, software malfunction, or malware infection. For valuable data, RAID is only one building block of a larger data loss prevention and recovery scheme – it cannot replace a backup plan.

RAID 0 edit

 
Diagram of a RAID 0 setup

RAID 0 (also known as a stripe set or striped volume) splits ("stripes") data evenly across two or more disks, without parity information, redundancy, or fault tolerance. Since RAID 0 provides no fault tolerance or redundancy, the failure of one drive will cause the entire array to fail; as a result of having data striped across all disks, the failure will result in total data loss. This configuration is typically implemented having speed as the intended goal.[2][3] RAID 0 is normally used to increase performance, although it can also be used as a way to create a large logical volume out of two or more physical disks.[4]

A RAID 0 setup can be created with disks of differing sizes, but the storage space added to the array by each disk is limited to the size of the smallest disk. For example, if a 120 GB disk is striped together with a 320 GB disk, the size of the array will be 120 GB × 2 = 240 GB. However, some RAID implementations would allow the remaining 200 GB to be used for other purposes.

The diagram in this section shows how the data is distributed into stripes on two disks, with A1:A2 as the first stripe, A3:A4 as the second one, etc. Once the stripe size is defined during the creation of a RAID 0 array, it needs to be maintained at all times. Since the stripes are accessed in parallel, an n-drive RAID 0 array appears as a single large disk with a data rate n times higher than the single-disk rate.

Performance edit

A RAID 0 array of n drives provides data read and write transfer rates up to n times as high as the individual drive rates, but with no data redundancy. As a result, RAID 0 is primarily used in applications that require high performance and are able to tolerate lower reliability, such as in scientific computing[5] or computer gaming.[6]

Some benchmarks of desktop applications show RAID 0 performance to be marginally better than a single drive.[7][8] Another article examined these claims and concluded that "striping does not always increase performance (in certain situations it will actually be slower than a non-RAID setup), but in most situations it will yield a significant improvement in performance".[9][10] Synthetic benchmarks show different levels of performance improvements when multiple HDDs or SSDs are used in a RAID 0 setup, compared with single-drive performance. However, some synthetic benchmarks also show a drop in performance for the same comparison.[11][12]

RAID 1 edit

 
Diagram of a RAID 1 setup

RAID 1 consists of an exact copy (or mirror) of a set of data on two or more disks; a classic RAID 1 mirrored pair contains two disks. This configuration offers no parity, striping, or spanning of disk space across multiple disks, since the data is mirrored on all disks belonging to the array, and the array can only be as big as the smallest member disk. This layout is useful when read performance or reliability is more important than write performance or the resulting data storage capacity.[13][14]

The array will continue to operate so long as at least one member drive is operational.[15]

Performance edit

Any read request can be serviced and handled by any drive in the array; thus, depending on the nature of I/O load, random read performance of a RAID 1 array may equal up to the sum of each member's performance,[a] while the write performance remains at the level of a single disk. However, if disks with different speeds are used in a RAID 1 array, overall write performance is equal to the speed of the slowest disk.[14][15]

Synthetic benchmarks show varying levels of performance improvements when multiple HDDs or SSDs are used in a RAID 1 setup, compared with single-drive performance. However, some synthetic benchmarks also show a drop in performance for the same comparison.[11][12]

RAID 2 edit

 
Diagram of a RAID 2 setup

RAID 2, which is rarely used in practice, stripes data at the bit (rather than block) level, and uses a Hamming code for error correction. The disks are synchronized by the controller to spin at the same angular orientation (they reach index at the same time[16]), so it generally cannot service multiple requests simultaneously.[17][18] However, depending with a high rate Hamming code, many spindles would operate in parallel to simultaneously transfer data so that "very high data transfer rates" are possible[19] as for example in the Thinking Machines' DataVault where 32 data bits were transmitted simultaneously. The IBM 353[20] also observed a similar usage of Hamming code and was capable of transmitting 64 data bits simultaneously, along with 8 ECC bits.

With all hard disk drives implementing internal error correction, the complexity of an external Hamming code offered little advantage over parity so RAID 2 has been rarely implemented; it is the only original level of RAID that is not currently used.[17][18]

RAID 3 edit

 
Diagram of a RAID 3 setup of six-byte blocks and two parity bytes, shown are two blocks of data in different colors.

RAID 3, which is rarely used in practice, consists of byte-level striping with a dedicated parity disk. One of the characteristics of RAID 3 is that it generally cannot service multiple requests simultaneously, which happens because any single block of data will, by definition, be spread across all members of the set and will reside in the same physical location on each disk. Therefore, any I/O operation requires activity on every disk and usually requires synchronized spindles.

This makes it suitable for applications that demand the highest transfer rates in long sequential reads and writes, for example uncompressed video editing. Applications that make small reads and writes from random disk locations will get the worst performance out of this level.[18]

The requirement that all disks spin synchronously (in a lockstep) added design considerations that provided no significant advantages over other RAID levels. Both RAID 3 and RAID 4 were quickly replaced by RAID 5.[21] RAID 3 was usually implemented in hardware, and the performance issues were addressed by using large disk caches.[18]

RAID 4 edit

 
Diagram 1: A RAID 4 setup with dedicated parity disk with each color representing the group of blocks in the respective parity block (a stripe)

RAID 4 consists of block-level striping with a dedicated parity disk. As a result of its layout, RAID 4 provides good performance of random reads, while the performance of random writes is low due to the need to write all parity data to a single disk,[22] unless the filesystem is RAID-4-aware and compensates for that.

An advantage of RAID 4 is that it can be quickly extended online, without parity recomputation, as long as the newly added disks are completely filled with 0-bytes.

In diagram 1, a read request for block A1 would be serviced by disk 0. A simultaneous read request for block B1 would have to wait, but a read request for B2 could be serviced concurrently by disk 1.

RAID 5 edit

 
Diagram of a RAID 5 layout with each color representing the group of data blocks and associated parity block (a stripe). This diagram shows Left Asynchronous layout

RAID 5 consists of block-level striping with distributed parity. Unlike in RAID 4, parity information is distributed among the drives. It requires that all drives but one be present to operate. Upon failure of a single drive, subsequent reads can be calculated from the distributed parity such that no data is lost.[5] RAID 5 requires at least three disks.[23]

There are many layouts of data and parity in a RAID 5 disk drive array depending upon the sequence of writing across the disks,[24] that is:

  1. the sequence of data blocks written, left to right or right to left on the disk array, of disks 0 to N.
  2. the location of the parity block at the beginning or end of the stripe.
  3. the location of the first block of a stripe with respect to parity of the previous stripe.

The figure shows 1) data blocks written left to right, 2) the parity block at the end of the stripe and 3) the first block of the next stripe not on the same disk as the parity block of the previous stripe. It can be designated as a Left Asynchronous RAID 5 layout[24] and this is the only layout identified in the last edition of The Raid Book[25] published by the defunct Raid Advisory Board.[26] In a Synchronous layout the data first block of the next stripe is written on the same drive as the parity block of the previous stripe.

In comparison to RAID 4, RAID 5's distributed parity evens out the stress of a dedicated parity disk among all RAID members. Additionally, write performance is increased since all RAID members participate in the serving of write requests. Although it will not be as efficient as a striping (RAID 0) setup, because parity must still be written, this is no longer a bottleneck.[27]

Since parity calculation is performed on the full stripe, small changes to the array experience write amplification[citation needed]: in the worst case when a single, logical sector is to be written, the original sector and the according parity sector need to be read, the original data is removed from the parity, the new data calculated into the parity and both the new data sector and the new parity sector are written.

RAID 6 edit

 
Diagram of a RAID 6 setup, which is identical to RAID 5 other than the addition of a second parity block

RAID 6 extends RAID 5 by adding another parity block; thus, it uses block-level striping with two parity blocks distributed across all member disks.[28]

As in RAID 5, there are many layouts of RAID 6 disk arrays depending upon the direction the data blocks are written, the location of the parity blocks with respect to the data blocks and whether or not the first data block of a subsequent stripe is written to the same drive as the last parity block of the prior stripe. The figure to the right is just one of many such layouts.

According to the Storage Networking Industry Association (SNIA), the definition of RAID 6 is: "Any form of RAID that can continue to execute read and write requests to all of a RAID array's virtual disks in the presence of any two concurrent disk failures. Several methods, including dual check data computations (parity and Reed–Solomon), orthogonal dual parity check data and diagonal parity, have been used to implement RAID Level 6."[29]

Performance edit

RAID 6 does not have a performance penalty for read operations, but it does have a performance penalty on write operations because of the overhead associated with parity calculations. Performance varies greatly depending on how RAID 6 is implemented in the manufacturer's storage architecture—in software, firmware, or by using firmware and specialized ASICs for intensive parity calculations. RAID 6 can read up to the same speed as RAID 5 with the same number of physical drives.[30]

When either diagonal or orthogonal dual parity is used, a second parity calculation is necessary for write operations. This doubles CPU overhead for RAID-6 writes, versus single-parity RAID levels. When a Reed Solomon code is used, the second parity calculation is unnecessary.[citation needed] Reed Solomon has the advantage of allowing all redundancy information to be contained within a given stripe.[clarification needed]

General parity system edit

It is possible to support a far greater number of drives by choosing the parity function more carefully. The issue we face is to ensure that a system of equations over the finite field   has a unique solution, so we will turn to the theory of polynomial equations. Consider the Galois field   with  . This field is isomorphic to a polynomial field   for a suitable irreducible polynomial   of degree   over  . We will represent the data elements   as polynomials   in the Galois field. Let   correspond to the stripes of data across hard drives encoded as field elements in this manner. We will use   to denote addition in the field, and concatenation to denote multiplication. The reuse of   is intentional: this is because addition in the finite field   represents to the XOR operator, so computing the sum of two elements is equivalent to computing XOR on the polynomial coefficients.

A generator of a field is an element of the field such that   is different for each non-negative  . This means each element of the field, except the value  , can be written as a power of   A finite field is guaranteed to have at least one generator. Pick one such generator  , and define   and   as follows:

 
 

As before, the first checksum   is just the XOR of each stripe, though interpreted now as a polynomial. The effect of   can be thought of as the action of a carefully chosen linear feedback shift register on the data chunk.[31] Unlike the bit shift in the simplified example, which could only be applied   times before the encoding began to repeat, applying the operator   multiple times is guaranteed to produce   unique invertible functions, which will allow a chunk length of   to support up to   data pieces.

If one data chunk is lost, the situation is similar to the one before. In the case of two lost data chunks, we can compute the recovery formulas algebraically. Suppose that   and   are the lost values with  , then, using the other values of  , we find constants   and  :

 
 

We can solve for   in the second equation and plug it into the first to find  , and then  .

Unlike P, The computation of Q is relatively CPU intensive, as it involves polynomial multiplication in  . This can be mitigated with a hardware implementation or by using an FPGA.

The above Vandermonde matrix solution can be extended to triple parity, but for beyond a Cauchy matrix construction is required.[32]

Comparison edit

The following table provides an overview of some considerations for standard RAID levels. In each case, array space efficiency is given as an expression in terms of the number of drives, n; this expression designates a fractional value between zero and one, representing the fraction of the sum of the drives' capacities that is available for use. For example, if three drives are arranged in RAID 3, this gives an array space efficiency of 1 − 1/n = 1 − 1/3 = 2/3 ≈ 67%; thus, if each drive in this example has a capacity of 250 GB, then the array has a total capacity of 750 GB but the capacity that is usable for data storage is only 500 GB. Different RAID configurations can also detect failure during so called data scrubbing.

Historically disks were subject to lower reliability and RAID levels were also used to detect which disk in the array had failed in addition to that a disk had failed. Though as noted by Patterson et al. even at the inception of RAID many (though not all) disks were already capable of finding internal errors using error correcting codes. In particular it is/was sufficient to have a mirrored set of disks to detect a failure, but two disks were not sufficient to detect which had failed in a disk array without error correcting features.[33] Modern RAID arrays depend for the most part on a disk's ability to identify itself as faulty which can be detected as part of a scrub. The redundant information is used to reconstruct the missing data, rather than to identify the faulted drive. Drives are considered to have faulted if they experience an unrecoverable read error, which occurs after a drive has retried many times to read data and failed. Enterprise drives may also report failure in far fewer tries than consumer drives as part of TLER to ensure a read request is fulfilled in a timely manner.[34]

Level Description Minimum number of drives[b] Space efficiency Fault tolerance Fault isolation Read performance Write performance
as factor of single disk
RAID 0 Block-level striping without parity or mirroring 2 1 None Drive Firmware Only n n
RAID 1 Mirroring without parity or striping 2 1/n n − 1 drive failures Drive Firmware or voting if n > 2 n[a][15] 1[c][15]
RAID 2 Bit-level striping with Hamming code for error correction 3 1 − 1/n log2 (n + 1) One drive failure[d] Drive Firmware and Parity Depends[clarification needed] Depends[clarification needed]
RAID 3 Byte-level striping with dedicated parity 3 1 − 1/n One drive failure Drive Firmware and Parity n − 1 n − 1[e]
RAID 4 Block-level striping with dedicated parity 3 1 − 1/n One drive failure Drive Firmware and Parity n − 1 n − 1[e][citation needed]
RAID 5 Block-level striping with distributed parity 3 1 − 1/n One drive failure Drive Firmware and Parity n[e] single sector: 1/4[f]
full stripe: n − 1[e][citation needed]
RAID 6 Block-level striping with double distributed parity 4 1 − 2/n Two drive failures Drive Firmware and Parity n[e] single sector: 1/6[f]
full stripe: n − 2[e][citation needed]

System implications edit

In measurement of the I/O performance of five filesystems with five storage configurations—single SSD, RAID 0, RAID 1, RAID 10, and RAID 5 it was shown that F2FS on RAID 0 and RAID 5 with eight SSDs outperforms EXT4 by 5 times and 50 times, respectively. The measurements also suggest that the RAID controller can be a significant bottleneck in building a RAID system with high speed SSDs.[36]

Nested RAID edit

Combinations of two or more standard RAID levels. They are also known as RAID 0+1 or RAID 01, RAID 0+3 or RAID 03, RAID 1+0 or RAID 10, RAID 5+0 or RAID 50, RAID 6+0 or RAID 60, and RAID 10+0 or RAID 100.

Non-standard variants edit

In addition to standard and nested RAID levels, alternatives include non-standard RAID levels, and non-RAID drive architectures. Non-RAID drive architectures are referred to by similar terms and acronyms, notably JBOD ("just a bunch of disks"), SPAN/BIG, and MAID ("massive array of idle disks").

Notes edit

  1. ^ a b Theoretical maximum, as low as single-disk performance in practice
  2. ^ Assumes a non-degenerate minimum number of drives
  3. ^ If disks with different speeds are used in a RAID 1 array, overall write performance is equal to the speed of the slowest disk.
  4. ^ RAID 2 can recover from one drive failure or repair corrupt data or parity when a corrupted bit's corresponding data and parity are good.
  5. ^ a b c d e f Assumes hardware capable of performing associated calculations fast enough
  6. ^ a b When modifying less than a stripe of data, RAID 5 and 6 requires the use of read-modify-write (RMW) or reconstruct-write (RCW) to reduce a small-write penalty. RMW writes data after reading the current stripe (so that it can have a difference to update the parity with); the spinaround time gives a fractional factor of 2, and the number of disks to write gives another factor of 2 in RAID 5 and 3 in RAID 6. RCW writes immediately, than reconstructs the parity by reading all associated stripes from other disks. RCW is usually faster than RMW when the number of disks is small, but has the downside of waking up all disks (additional start-stop cycles may shorten lifespan). RCW is the only possible write method for a degraded stripe.[35]

References edit

  1. ^ "Common raid Disk Data Format (DDF)". SNIA.org. Storage Networking Industry Association. Retrieved 2013-04-23.
  2. ^ "RAID 0 Data Recovery". DataRecovery.net. Retrieved 2015-04-30.
  3. ^ "Understanding RAID". CRU-Inc.com. Retrieved 2015-04-30.
  4. ^ "How to Combine Multiple Hard Drives Into One Volume for Cheap, High-Capacity Storage". LifeHacker.com. 2013-02-26. Retrieved 2015-04-30.
  5. ^ a b Chen, Peter; Lee, Edward; Gibson, Garth; Katz, Randy; Patterson, David (1994). "RAID: High-Performance, Reliable Secondary Storage". ACM Computing Surveys. 26 (2): 145–185. CiteSeerX 10.1.1.41.3889. doi:10.1145/176979.176981. S2CID 207178693.
  6. ^ de Kooter, Sebastiaan (2015-04-13). "Gaming storage shootout 2015: SSD, HDD or RAID 0, which is best?". GamePlayInside.com. Retrieved 2015-09-22.
  7. ^ "Western Digital's Raptors in RAID-0: Are two drives better than one?". AnandTech.com. AnandTech. July 1, 2004. Retrieved 2007-11-24.
  8. ^ "Hitachi Deskstar 7K1000: Two Terabyte RAID Redux". AnandTech.com. AnandTech. April 23, 2007. Retrieved 2007-11-24.
  9. ^ "RAID 0: Hype or blessing?". Tweakers.net. Persgroep Online Services. August 7, 2004. Retrieved 2008-07-23.
  10. ^ "Does RAID0 Really Increase Disk Performance?". HardwareSecrets.com. November 1, 2006.
  11. ^ a b Larabel, Michael (2014-10-22). "Btrfs RAID HDD Testing on Ubuntu Linux 14.10". Phoronix. Retrieved 2015-09-19.
  12. ^ a b Larabel, Michael (2014-10-29). "Btrfs on 4 × Intel SSDs In RAID 0/1/5/6/10". Phoronix. Retrieved 2015-09-19.
  13. ^ "FreeBSD Handbook: 19.3. RAID 1 – Mirroring". FreeBSD.org. 2014-03-23. Retrieved 2014-06-11.
  14. ^ a b "Which RAID Level is Right for Me?: RAID 1 (Mirroring)". Adaptec.com. Adaptec. Retrieved 2014-01-02.
  15. ^ a b c d "Selecting the Best RAID Level: RAID 1 Arrays (Sun StorageTek SAS RAID HBA Installation Guide)". Docs.Oracle.com. Oracle Corporation. 2010-12-23. Retrieved 2014-01-02.
  16. ^ "RAID 2". Techopedia. 27 February 2012. Retrieved 11 December 2019.
  17. ^ a b Vadala, Derek (2003). Managing RAID on Linux. O'Reilly Series (illustrated ed.). O'Reilly. p. 6. ISBN 9781565927308.
  18. ^ a b c d Marcus, Evan; Stern, Hal (2003). Blueprints for high availability (2, illustrated ed.). John Wiley and Sons. p. 167. ISBN 9780471430261.
  19. ^ The RAIDbook, 4th Edition, The RAID Advisory Board, June 1995, p.101
  20. ^ "IBM Stretch (aka IBM 7030 Data Processing System)". www.brouhaha.com. Retrieved 2023-09-13.
  21. ^ Meyers, Michael; Jernigan, Scott (2003). Mike Meyers' A+ Guide to Managing and Troubleshooting PCs (illustrated ed.). McGraw-Hill Professional. p. 321. ISBN 9780072231465.
  22. ^ Natarajan, Ramesh (2011-11-21). "RAID 2, RAID 3, RAID 4 and RAID 6 Explained with Diagrams". TheGeekStuff.com. Retrieved 2015-01-02.
  23. ^ "RAID 5 Data Recovery FAQ". VantageTech.com. Vantage Technologies. Retrieved 2014-07-16.
  24. ^ a b "RAID Information - Linux RAID-5 Algorithms". Ashford computer Consulting Service. Retrieved February 16, 2021.
  25. ^ Massigilia, Paul (February 1997). The RAID Book, 6th Edition. RAID Advisory Board. pp. 101–129.
  26. ^ . RAID Advisory Board. April 6, 2001. Archived from the original on 2001-04-06. Retrieved February 16, 2021. Last valid archived webpage at Wayback Machine
  27. ^ Koren, Israel. "Basic RAID Organizations". ECS.UMass.edu. University of Massachusetts. Retrieved 2014-11-04.
  28. ^ "Sun StorageTek SAS RAID HBA Installation Guide, Appendix F: Selecting the Best RAID Level: RAID 6 Arrays". Docs.Oracle.com. 2010-12-23. Retrieved 2015-08-27.
  29. ^ "Dictionary R". SNIA.org. Storage Networking Industry Association. Retrieved 2007-11-24.
  30. ^ Faith, Rickard E. (13 May 2009). "A Comparison of Software RAID Types". {{cite journal}}: Cite journal requires |journal= (help)
  31. ^ Anvin, H. Peter (May 21, 2009). "The Mathematics of RAID-6" (PDF). Kernel.org. Linux Kernel Organization. Retrieved November 4, 2009.
  32. ^ "bcachefs-tools: raid.c". GitHub. 27 May 2023.
  33. ^ Patterson, David A.; Gibson, Garth; Katz, Randy H. (1988). "A case for redundant arrays of inexpensive disks (RAID)" (PDF). Proceedings of the 1988 ACM SIGMOD international conference on Management of data - SIGMOD '88. p. 112. doi:10.1145/50202.50214. ISBN 0897912683. S2CID 52859427. Retrieved 25 June 2022. A single parity disk can detect a single error, but to correct an error we need enough check disks to identify the disk with the error. [...] Most check disks in the level 2 RAID are used to determine which disk failed, for only one redundant parity disk is needed to detect an error. These extra disks are truly "redundant" since most disk controllers can already detect If a dusk failed either through special signals provided in the disk interface or the extra checking information at the end of a sector
  34. ^ "Enterprise vs Desktop Harddrives" (PDF). Intel.com. Intel. p. 10.
  35. ^ Thomasian, Alexander (February 2005). "Reconstruct versus read-modify writes in RAID". Information Processing Letters. 93 (4): 163–168. doi:10.1016/j.ipl.2004.10.009.
  36. ^ Park, Chanhyun; Lee, Seongjin; Won, Youjip (2014). "An Analysis on Empirical Performance of SSD-Based RAID". Information Sciences and Systems 2014. pp. 395–405. doi:10.1007/978-3-319-09465-6_41. ISBN 978-3-319-09464-9. {{cite book}}: |journal= ignored (help)

Further reading edit

  • . Support.Dell.com. Dell. 2009. Archived from the original on 2009-02-20. Retrieved 2016-04-15.
  • Redundant Arrays of Inexpensive Disks (RAIDs), chapter 38 from the Operating Systems: Three Easy Pieces book by Remzi H. Arpaci-Dusseau and Andrea C. Arpaci-Dusseau

External links edit

  • IBM summary on RAID levels
  • RAID 5 parity explanation and checking tool
  • RAID Calculator for Standard RAID Levels and Other RAID Tools
  • Sun StorEdge 3000 Family Configuration Service 2.5 User's Guide: RAID Basics

standard, raid, levels, computer, storage, standard, raid, levels, comprise, basic, raid, redundant, array, independent, disks, redundant, array, inexpensive, disks, configurations, that, employ, techniques, striping, mirroring, parity, create, large, reliable. In computer storage the standard RAID levels comprise a basic set of RAID redundant array of independent disks or redundant array of inexpensive disks configurations that employ the techniques of striping mirroring or parity to create large reliable data stores from multiple general purpose computer hard disk drives HDDs The most common types are RAID 0 striping RAID 1 mirroring and its variants RAID 5 distributed parity and RAID 6 dual parity Multiple RAID levels can also be combined or nested for instance RAID 10 striping of mirrors or RAID 01 mirroring stripe sets RAID levels and their associated data formats are standardized by the Storage Networking Industry Association SNIA in the Common RAID Disk Drive Format DDF standard 1 The numerical values only serve as identifiers and do not signify performance reliability generation or any other metric While most RAID levels can provide good protection against and recovery from hardware defects or defective sectors read errors hard errors they do not provide any protection against data loss due to catastrophic failures fire water or soft errors such as user error software malfunction or malware infection For valuable data RAID is only one building block of a larger data loss prevention and recovery scheme it cannot replace a backup plan Contents 1 RAID 0 1 1 Performance 2 RAID 1 2 1 Performance 3 RAID 2 4 RAID 3 5 RAID 4 6 RAID 5 7 RAID 6 7 1 Performance 7 2 General parity system 8 Comparison 9 System implications 10 Nested RAID 11 Non standard variants 12 Notes 13 References 14 Further reading 15 External linksRAID 0 editSee also JBOD nbsp Diagram of a RAID 0 setupRAID 0 also known as a stripe set or striped volume splits stripes data evenly across two or more disks without parity information redundancy or fault tolerance Since RAID 0 provides no fault tolerance or redundancy the failure of one drive will cause the entire array to fail as a result of having data striped across all disks the failure will result in total data loss This configuration is typically implemented having speed as the intended goal 2 3 RAID 0 is normally used to increase performance although it can also be used as a way to create a large logical volume out of two or more physical disks 4 A RAID 0 setup can be created with disks of differing sizes but the storage space added to the array by each disk is limited to the size of the smallest disk For example if a 120 GB disk is striped together with a 320 GB disk the size of the array will be 120 GB 2 240 GB However some RAID implementations would allow the remaining 200 GB to be used for other purposes The diagram in this section shows how the data is distributed into stripes on two disks with A1 A2 as the first stripe A3 A4 as the second one etc Once the stripe size is defined during the creation of a RAID 0 array it needs to be maintained at all times Since the stripes are accessed in parallel an n drive RAID 0 array appears as a single large disk with a data rate n times higher than the single disk rate Performance edit A RAID 0 array of n drives provides data read and write transfer rates up to n times as high as the individual drive rates but with no data redundancy As a result RAID 0 is primarily used in applications that require high performance and are able to tolerate lower reliability such as in scientific computing 5 or computer gaming 6 Some benchmarks of desktop applications show RAID 0 performance to be marginally better than a single drive 7 8 Another article examined these claims and concluded that striping does not always increase performance in certain situations it will actually be slower than a non RAID setup but in most situations it will yield a significant improvement in performance 9 10 Synthetic benchmarks show different levels of performance improvements when multiple HDDs or SSDs are used in a RAID 0 setup compared with single drive performance However some synthetic benchmarks also show a drop in performance for the same comparison 11 12 RAID 1 editSee also RAID 1E nbsp Diagram of a RAID 1 setupRAID 1 consists of an exact copy or mirror of a set of data on two or more disks a classic RAID 1 mirrored pair contains two disks This configuration offers no parity striping or spanning of disk space across multiple disks since the data is mirrored on all disks belonging to the array and the array can only be as big as the smallest member disk This layout is useful when read performance or reliability is more important than write performance or the resulting data storage capacity 13 14 The array will continue to operate so long as at least one member drive is operational 15 Performance edit Any read request can be serviced and handled by any drive in the array thus depending on the nature of I O load random read performance of a RAID 1 array may equal up to the sum of each member s performance a while the write performance remains at the level of a single disk However if disks with different speeds are used in a RAID 1 array overall write performance is equal to the speed of the slowest disk 14 15 Synthetic benchmarks show varying levels of performance improvements when multiple HDDs or SSDs are used in a RAID 1 setup compared with single drive performance However some synthetic benchmarks also show a drop in performance for the same comparison 11 12 RAID 2 edit nbsp Diagram of a RAID 2 setupRAID 2 which is rarely used in practice stripes data at the bit rather than block level and uses a Hamming code for error correction The disks are synchronized by the controller to spin at the same angular orientation they reach index at the same time 16 so it generally cannot service multiple requests simultaneously 17 18 However depending with a high rate Hamming code many spindles would operate in parallel to simultaneously transfer data so that very high data transfer rates are possible 19 as for example in the Thinking Machines DataVault where 32 data bits were transmitted simultaneously The IBM 353 20 also observed a similar usage of Hamming code and was capable of transmitting 64 data bits simultaneously along with 8 ECC bits With all hard disk drives implementing internal error correction the complexity of an external Hamming code offered little advantage over parity so RAID 2 has been rarely implemented it is the only original level of RAID that is not currently used 17 18 RAID 3 edit nbsp Diagram of a RAID 3 setup of six byte blocks and two parity bytes shown are two blocks of data in different colors RAID 3 which is rarely used in practice consists of byte level striping with a dedicated parity disk One of the characteristics of RAID 3 is that it generally cannot service multiple requests simultaneously which happens because any single block of data will by definition be spread across all members of the set and will reside in the same physical location on each disk Therefore any I O operation requires activity on every disk and usually requires synchronized spindles This makes it suitable for applications that demand the highest transfer rates in long sequential reads and writes for example uncompressed video editing Applications that make small reads and writes from random disk locations will get the worst performance out of this level 18 The requirement that all disks spin synchronously in a lockstep added design considerations that provided no significant advantages over other RAID levels Both RAID 3 and RAID 4 were quickly replaced by RAID 5 21 RAID 3 was usually implemented in hardware and the performance issues were addressed by using large disk caches 18 RAID 4 edit nbsp Diagram 1 A RAID 4 setup with dedicated parity disk with each color representing the group of blocks in the respective parity block a stripe RAID 4 consists of block level striping with a dedicated parity disk As a result of its layout RAID 4 provides good performance of random reads while the performance of random writes is low due to the need to write all parity data to a single disk 22 unless the filesystem is RAID 4 aware and compensates for that An advantage of RAID 4 is that it can be quickly extended online without parity recomputation as long as the newly added disks are completely filled with 0 bytes In diagram 1 a read request for block A1 would be serviced by disk 0 A simultaneous read request for block B1 would have to wait but a read request for B2 could be serviced concurrently by disk 1 RAID 5 edit nbsp Diagram of a RAID 5 layout with each color representing the group of data blocks and associated parity block a stripe This diagram shows Left Asynchronous layoutRAID 5 consists of block level striping with distributed parity Unlike in RAID 4 parity information is distributed among the drives It requires that all drives but one be present to operate Upon failure of a single drive subsequent reads can be calculated from the distributed parity such that no data is lost 5 RAID 5 requires at least three disks 23 There are many layouts of data and parity in a RAID 5 disk drive array depending upon the sequence of writing across the disks 24 that is the sequence of data blocks written left to right or right to left on the disk array of disks 0 to N the location of the parity block at the beginning or end of the stripe the location of the first block of a stripe with respect to parity of the previous stripe The figure shows 1 data blocks written left to right 2 the parity block at the end of the stripe and 3 the first block of the next stripe not on the same disk as the parity block of the previous stripe It can be designated as a Left Asynchronous RAID 5 layout 24 and this is the only layout identified in the last edition of The Raid Book 25 published by the defunct Raid Advisory Board 26 In a Synchronous layout the data first block of the next stripe is written on the same drive as the parity block of the previous stripe In comparison to RAID 4 RAID 5 s distributed parity evens out the stress of a dedicated parity disk among all RAID members Additionally write performance is increased since all RAID members participate in the serving of write requests Although it will not be as efficient as a striping RAID 0 setup because parity must still be written this is no longer a bottleneck 27 Since parity calculation is performed on the full stripe small changes to the array experience write amplification citation needed in the worst case when a single logical sector is to be written the original sector and the according parity sector need to be read the original data is removed from the parity the new data calculated into the parity and both the new data sector and the new parity sector are written RAID 6 edit nbsp Diagram of a RAID 6 setup which is identical to RAID 5 other than the addition of a second parity blockRAID 6 extends RAID 5 by adding another parity block thus it uses block level striping with two parity blocks distributed across all member disks 28 As in RAID 5 there are many layouts of RAID 6 disk arrays depending upon the direction the data blocks are written the location of the parity blocks with respect to the data blocks and whether or not the first data block of a subsequent stripe is written to the same drive as the last parity block of the prior stripe The figure to the right is just one of many such layouts According to the Storage Networking Industry Association SNIA the definition of RAID 6 is Any form of RAID that can continue to execute read and write requests to all of a RAID array s virtual disks in the presence of any two concurrent disk failures Several methods including dual check data computations parity and Reed Solomon orthogonal dual parity check data and diagonal parity have been used to implement RAID Level 6 29 Performance edit RAID 6 does not have a performance penalty for read operations but it does have a performance penalty on write operations because of the overhead associated with parity calculations Performance varies greatly depending on how RAID 6 is implemented in the manufacturer s storage architecture in software firmware or by using firmware and specialized ASICs for intensive parity calculations RAID 6 can read up to the same speed as RAID 5 with the same number of physical drives 30 When either diagonal or orthogonal dual parity is used a second parity calculation is necessary for write operations This doubles CPU overhead for RAID 6 writes versus single parity RAID levels When a Reed Solomon code is used the second parity calculation is unnecessary citation needed Reed Solomon has the advantage of allowing all redundancy information to be contained within a given stripe clarification needed General parity system edit It is possible to support a far greater number of drives by choosing the parity function more carefully The issue we face is to ensure that a system of equations over the finite field Z 2 displaystyle mathbb Z 2 nbsp has a unique solution so we will turn to the theory of polynomial equations Consider the Galois field G F m displaystyle GF m nbsp with m 2 k displaystyle m 2 k nbsp This field is isomorphic to a polynomial field F 2 x p x displaystyle F 2 x p x nbsp for a suitable irreducible polynomial p x displaystyle p x nbsp of degree k displaystyle k nbsp over Z 2 displaystyle mathbb Z 2 nbsp We will represent the data elements D displaystyle D nbsp as polynomials D d k 1 x k 1 d k 2 x k 2 d 1 x d 0 displaystyle mathbf D d k 1 x k 1 d k 2 x k 2 d 1 x d 0 nbsp in the Galois field Let D 0 D n 1 G F m displaystyle mathbf D 0 mathbf D n 1 in GF m nbsp correspond to the stripes of data across hard drives encoded as field elements in this manner We will use displaystyle oplus nbsp to denote addition in the field and concatenation to denote multiplication The reuse of displaystyle oplus nbsp is intentional this is because addition in the finite field Z 2 displaystyle mathbb Z 2 nbsp represents to the XOR operator so computing the sum of two elements is equivalent to computing XOR on the polynomial coefficients A generator of a field is an element of the field such that g i displaystyle g i nbsp is different for each non negative i lt m 1 displaystyle i lt m 1 nbsp This means each element of the field except the value 0 displaystyle 0 nbsp can be written as a power of g displaystyle g nbsp A finite field is guaranteed to have at least one generator Pick one such generator g displaystyle g nbsp and define P displaystyle mathbf P nbsp and Q displaystyle mathbf Q nbsp as follows P i D i D 0 D 1 D 2 D n 1 displaystyle mathbf P bigoplus i mathbf D i mathbf D 0 oplus mathbf D 1 oplus mathbf D 2 oplus oplus mathbf D n 1 nbsp Q i g i D i g 0 D 0 g 1 D 1 g 2 D 2 g n 1 D n 1 displaystyle mathbf Q bigoplus i g i mathbf D i g 0 mathbf D 0 oplus g 1 mathbf D 1 oplus g 2 mathbf D 2 oplus oplus g n 1 mathbf D n 1 nbsp As before the first checksum P displaystyle mathbf P nbsp is just the XOR of each stripe though interpreted now as a polynomial The effect of g i displaystyle g i nbsp can be thought of as the action of a carefully chosen linear feedback shift register on the data chunk 31 Unlike the bit shift in the simplified example which could only be applied k displaystyle k nbsp times before the encoding began to repeat applying the operator g displaystyle g nbsp multiple times is guaranteed to produce m 2 k 1 displaystyle m 2 k 1 nbsp unique invertible functions which will allow a chunk length of k displaystyle k nbsp to support up to 2 k 1 displaystyle 2 k 1 nbsp data pieces If one data chunk is lost the situation is similar to the one before In the case of two lost data chunks we can compute the recovery formulas algebraically Suppose that D i displaystyle mathbf D i nbsp and D j displaystyle mathbf D j nbsp are the lost values with i j displaystyle i neq j nbsp then using the other values of D displaystyle D nbsp we find constants A displaystyle A nbsp and B displaystyle B nbsp A P ℓ ℓ i a n d ℓ j D ℓ D i D j displaystyle A mathbf P oplus bigoplus ell ell not i mathrm and ell not j D ell D i oplus D j nbsp B Q ℓ ℓ i a n d ℓ j g ℓ D ℓ g i D i g j D j displaystyle B mathbf Q oplus bigoplus ell ell not i mathrm and ell not j g ell D ell g i D i oplus g j D j nbsp We can solve for D i displaystyle D i nbsp in the second equation and plug it into the first to find D j g m i j 1 1 g m i B A displaystyle D j g m i j oplus 1 1 g m i B oplus A nbsp and then D i A D j displaystyle D i A oplus D j nbsp Unlike P The computation of Q is relatively CPU intensive as it involves polynomial multiplication in F 2 x p x displaystyle F 2 x p x nbsp This can be mitigated with a hardware implementation or by using an FPGA The above Vandermonde matrix solution can be extended to triple parity but for beyond a Cauchy matrix construction is required 32 Comparison editSee also Nested RAID levels Comparison The following table provides an overview of some considerations for standard RAID levels In each case array space efficiency is given as an expression in terms of the number of drives n this expression designates a fractional value between zero and one representing the fraction of the sum of the drives capacities that is available for use For example if three drives are arranged in RAID 3 this gives an array space efficiency of 1 1 n 1 1 3 2 3 67 thus if each drive in this example has a capacity of 250 GB then the array has a total capacity of 750 GB but the capacity that is usable for data storage is only 500 GB Different RAID configurations can also detect failure during so called data scrubbing Historically disks were subject to lower reliability and RAID levels were also used to detect which disk in the array had failed in addition to that a disk had failed Though as noted by Patterson et al even at the inception of RAID many though not all disks were already capable of finding internal errors using error correcting codes In particular it is was sufficient to have a mirrored set of disks to detect a failure but two disks were not sufficient to detect which had failed in a disk array without error correcting features 33 Modern RAID arrays depend for the most part on a disk s ability to identify itself as faulty which can be detected as part of a scrub The redundant information is used to reconstruct the missing data rather than to identify the faulted drive Drives are considered to have faulted if they experience an unrecoverable read error which occurs after a drive has retried many times to read data and failed Enterprise drives may also report failure in far fewer tries than consumer drives as part of TLER to ensure a read request is fulfilled in a timely manner 34 Level Description Minimum number of drives b Space efficiency Fault tolerance Fault isolation Read performance Write performanceas factor of single diskRAID 0 Block level striping without parity or mirroring 2 1 None Drive Firmware Only n nRAID 1 Mirroring without parity or striping 2 1 n n 1 drive failures Drive Firmware or voting if n gt 2 n a 15 1 c 15 RAID 2 Bit level striping with Hamming code for error correction 3 1 1 n log2 n 1 One drive failure d Drive Firmware and Parity Depends clarification needed Depends clarification needed RAID 3 Byte level striping with dedicated parity 3 1 1 n One drive failure Drive Firmware and Parity n 1 n 1 e RAID 4 Block level striping with dedicated parity 3 1 1 n One drive failure Drive Firmware and Parity n 1 n 1 e citation needed RAID 5 Block level striping with distributed parity 3 1 1 n One drive failure Drive Firmware and Parity n e single sector 1 4 f full stripe n 1 e citation needed RAID 6 Block level striping with double distributed parity 4 1 2 n Two drive failures Drive Firmware and Parity n e single sector 1 6 f full stripe n 2 e citation needed System implications editIn measurement of the I O performance of five filesystems with five storage configurations single SSD RAID 0 RAID 1 RAID 10 and RAID 5 it was shown that F2FS on RAID 0 and RAID 5 with eight SSDs outperforms EXT4 by 5 times and 50 times respectively The measurements also suggest that the RAID controller can be a significant bottleneck in building a RAID system with high speed SSDs 36 Nested RAID editMain article Nested RAID levels Combinations of two or more standard RAID levels They are also known as RAID 0 1 or RAID 01 RAID 0 3 or RAID 03 RAID 1 0 or RAID 10 RAID 5 0 or RAID 50 RAID 6 0 or RAID 60 and RAID 10 0 or RAID 100 Non standard variants editMain articles Non standard RAID levels and Non RAID drive architectures In addition to standard and nested RAID levels alternatives include non standard RAID levels and non RAID drive architectures Non RAID drive architectures are referred to by similar terms and acronyms notably JBOD just a bunch of disks SPAN BIG and MAID massive array of idle disks Notes edit a b Theoretical maximum as low as single disk performance in practice Assumes a non degenerate minimum number of drives If disks with different speeds are used in a RAID 1 array overall write performance is equal to the speed of the slowest disk RAID 2 can recover from one drive failure or repair corrupt data or parity when a corrupted bit s corresponding data and parity are good a b c d e f Assumes hardware capable of performing associated calculations fast enough a b When modifying less than a stripe of data RAID 5 and 6 requires the use of read modify write RMW or reconstruct write RCW to reduce a small write penalty RMW writes data after reading the current stripe so that it can have a difference to update the parity with the spinaround time gives a fractional factor of 2 and the number of disks to write gives another factor of 2 in RAID 5 and 3 in RAID 6 RCW writes immediately than reconstructs the parity by reading all associated stripes from other disks RCW is usually faster than RMW when the number of disks is small but has the downside of waking up all disks additional start stop cycles may shorten lifespan RCW is the only possible write method for a degraded stripe 35 References edit Common raid Disk Data Format DDF SNIA org Storage Networking Industry Association Retrieved 2013 04 23 RAID 0 Data Recovery DataRecovery net Retrieved 2015 04 30 Understanding RAID CRU Inc com Retrieved 2015 04 30 How to Combine Multiple Hard Drives Into One Volume for Cheap High Capacity Storage LifeHacker com 2013 02 26 Retrieved 2015 04 30 a b Chen Peter Lee Edward Gibson Garth Katz Randy Patterson David 1994 RAID High Performance Reliable Secondary Storage ACM Computing Surveys 26 2 145 185 CiteSeerX 10 1 1 41 3889 doi 10 1145 176979 176981 S2CID 207178693 de Kooter Sebastiaan 2015 04 13 Gaming storage shootout 2015 SSD HDD or RAID 0 which is best GamePlayInside com Retrieved 2015 09 22 Western Digital s Raptors in RAID 0 Are two drives better than one AnandTech com AnandTech July 1 2004 Retrieved 2007 11 24 Hitachi Deskstar 7K1000 Two Terabyte RAID Redux AnandTech com AnandTech April 23 2007 Retrieved 2007 11 24 RAID 0 Hype or blessing Tweakers net Persgroep Online Services August 7 2004 Retrieved 2008 07 23 Does RAID0 Really Increase Disk Performance HardwareSecrets com November 1 2006 a b Larabel Michael 2014 10 22 Btrfs RAID HDD Testing on Ubuntu Linux 14 10 Phoronix Retrieved 2015 09 19 a b Larabel Michael 2014 10 29 Btrfs on 4 Intel SSDs In RAID 0 1 5 6 10 Phoronix Retrieved 2015 09 19 FreeBSD Handbook 19 3 RAID 1 Mirroring FreeBSD org 2014 03 23 Retrieved 2014 06 11 a b Which RAID Level is Right for Me RAID 1 Mirroring Adaptec com Adaptec Retrieved 2014 01 02 a b c d Selecting the Best RAID Level RAID 1 Arrays Sun StorageTek SAS RAID HBA Installation Guide Docs Oracle com Oracle Corporation 2010 12 23 Retrieved 2014 01 02 RAID 2 Techopedia 27 February 2012 Retrieved 11 December 2019 a b Vadala Derek 2003 Managing RAID on Linux O Reilly Series illustrated ed O Reilly p 6 ISBN 9781565927308 a b c d Marcus Evan Stern Hal 2003 Blueprints for high availability 2 illustrated ed John Wiley and Sons p 167 ISBN 9780471430261 The RAIDbook 4th Edition The RAID Advisory Board June 1995 p 101 IBM Stretch aka IBM 7030 Data Processing System www brouhaha com Retrieved 2023 09 13 Meyers Michael Jernigan Scott 2003 Mike Meyers A Guide to Managing and Troubleshooting PCs illustrated ed McGraw Hill Professional p 321 ISBN 9780072231465 Natarajan Ramesh 2011 11 21 RAID 2 RAID 3 RAID 4 and RAID 6 Explained with Diagrams TheGeekStuff com Retrieved 2015 01 02 RAID 5 Data Recovery FAQ VantageTech com Vantage Technologies Retrieved 2014 07 16 a b RAID Information Linux RAID 5 Algorithms Ashford computer Consulting Service Retrieved February 16 2021 Massigilia Paul February 1997 The RAID Book 6th Edition RAID Advisory Board pp 101 129 Welcome to the RAID Advisory Board RAID Advisory Board April 6 2001 Archived from the original on 2001 04 06 Retrieved February 16 2021 Last valid archived webpage at Wayback Machine Koren Israel Basic RAID Organizations ECS UMass edu University of Massachusetts Retrieved 2014 11 04 Sun StorageTek SAS RAID HBA Installation Guide Appendix F Selecting the Best RAID Level RAID 6 Arrays Docs Oracle com 2010 12 23 Retrieved 2015 08 27 Dictionary R SNIA org Storage Networking Industry Association Retrieved 2007 11 24 Faith Rickard E 13 May 2009 A Comparison of Software RAID Types a href Template Cite journal html title Template Cite journal cite journal a Cite journal requires journal help Anvin H Peter May 21 2009 The Mathematics of RAID 6 PDF Kernel org Linux Kernel Organization Retrieved November 4 2009 bcachefs tools raid c GitHub 27 May 2023 Patterson David A Gibson Garth Katz Randy H 1988 A case for redundant arrays of inexpensive disks RAID PDF Proceedings of the 1988 ACM SIGMOD international conference on Management of data SIGMOD 88 p 112 doi 10 1145 50202 50214 ISBN 0897912683 S2CID 52859427 Retrieved 25 June 2022 A single parity disk can detect a single error but to correct an error we need enough check disks to identify the disk with the error Most check disks in the level 2 RAID are used to determine which disk failed for only one redundant parity disk is needed to detect an error These extra disks are truly redundant since most disk controllers can already detect If a dusk failed either through special signals provided in the disk interface or the extra checking information at the end of a sector Enterprise vs Desktop Harddrives PDF Intel com Intel p 10 Thomasian Alexander February 2005 Reconstruct versus read modify writes in RAID Information Processing Letters 93 4 163 168 doi 10 1016 j ipl 2004 10 009 Park Chanhyun Lee Seongjin Won Youjip 2014 An Analysis on Empirical Performance of SSD Based RAID Information Sciences and Systems 2014 pp 395 405 doi 10 1007 978 3 319 09465 6 41 ISBN 978 3 319 09464 9 a href Template Cite book html title Template Cite book cite book a journal ignored help Further reading edit Learning About RAID Support Dell com Dell 2009 Archived from the original on 2009 02 20 Retrieved 2016 04 15 Redundant Arrays of Inexpensive Disks RAIDs chapter 38 from the Operating Systems Three Easy Pieces book by Remzi H Arpaci Dusseau and Andrea C Arpaci DusseauExternal links editIBM summary on RAID levels RAID 5 parity explanation and checking tool RAID Calculator for Standard RAID Levels and Other RAID Tools Sun StorEdge 3000 Family Configuration Service 2 5 User s Guide RAID Basics Retrieved from https en wikipedia org w index php title Standard RAID levels amp oldid 1181992674 RAID 0, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.