fbpx
Wikipedia

IEC 61131-3

IEC 61131-3 is the third part (of 10) of the open international standard IEC 61131 for programmable logic controllers. It was first published in December 1993[1] by the IEC; the current (third) edition was published in February 2013.[2]

Part 3 of IEC 61131 deals with basic software architecture and programming languages of the control program within PLC. It defines three graphical and two textual programming language standards:

Data types

  • Elementary Data Type
    • Bit Strings – groups of on/off values
      • BOOL - 1 bit (0,1)
      • BYTE – 8 bit (1 byte)
      • WORD – 16 bit (2 byte)
      • DWORD – 32 bit (4 byte)
      • LWORD – 64 bit (8 byte)
    • INTEGER – whole numbers (Considering byte size 8 bits)
      • SINT – signed short integer (1 byte)
      • INT – signed integer (2 byte)
      • DINT – signed double integer (4 byte)
      • LINT – signed long integer (8 byte)
      • USINT – Unsigned short integer (1 byte)
      • UINT – Unsigned integer (2 byte)
      • UDINT – Unsigned double integer (4 byte)
      • ULINT – Unsigned long integer (8 byte)
    • REAL – floating point IEC 60559 (same as IEEE 754-2008)
      • REAL – (4 byte)
      • LREAL – (8 byte)
Duration literals
Unit Description
d Day
h Hour
m Minute
s Second
ms Millisecond
us Microsecond
ns Nanosecond
    • Duration [4]
      • TIME – (4 byte). Literals in the form of T#5m90s15ms
      • LTIME – (8 byte). Literals extend to nanoseconds in the form of T#5m90s15ms542us15ns
    • Date
      • DATE – calendar date (Size is not specified)
      • LDATE – calendar date (Size is not specified)
    • Time of day
      • TIME_OF_DAY / TOD – clock time(Size is not specified)
      • LTIME_OF_DAY / LTOD – clock time (8 byte)
    • Date and time of Day
      • DATE_AND_TIME / DT – time and date(Size is not specified)
      • LDATE_AND_TIME / LDT – time and date(8 byte)
    • Character / Character string
      • CHAR – Single-byte character (1 byte)
      • WCHAR – Double-byte character (2 byte)
      • STRING – Variable-length single-byte character string. Literals specified with single quote, 'This is a STRING Literal'
      • WSTRING – Variable-length double-byte character string. Literals specified with a double quote, "This is a WSTRING Literal"
STRING escape sequences
Escape sequence Produces
$$ $
$' '
$L linefeed
$N newline
$P page (form feed)
$R return
$T tab
$xx hex value
  • Generic Data Types – Only available for the input / output/ in-out variables of system-defined Program Organization Units (POUs, see below)
    • ANY
      • ANY_DERIVED
      • ANY_ELEMENTARY
        • ANY_MAGNITUDE
          • ANY_NUM
            • ANY_REAL: LREAL, REAL
            • ANY_INT
              • ANY_UNSIGNED: ULINT, UDINT, UINT, USINT
              • ANY_SIGNED: LINT, DINT, INT, SINT
          • ANY_DURATION: TIME, LTIME
        • ANY_BIT: LWORD, DWORD, WORD, BYTE, BOOL
        • ANY_CHARS
          • ANY_STRING: STRING, WSTRING
          • ANY_CHAR: CHAR, WCHAR
        • ANY_DATE: DATE_AND_TIME (DT), DATE_AND_TIME(LDT), DATE, TIME_OF_DAY (TOD), LTIME_OF_DAY(LTOD)
  • User-defined Data Types
    • Enumerated data type
    • Enumerated data type with named value
    • Subrange data type – puts limits on value i.e., INT(4 .. 20) for current
    • Array data type – multiple values stored in the same variable.
    • Structured data type – composite of several variables and types.
    • Directly derived data type – type derived from one of the above types to give new name and initial value as a type.
    • References – a kind of strongly typed pointer. Arithmetic operation of the value of this type is prohibited.

Variables

Variable attributes: RETAIN, CONSTANT, AT

  • Global
  • Direct (local)
  • I/O Mapping – Input, Output, I/O
  • External
  • Temporary

Configuration

  • Resource – Like a CPU
  • Tasks – Can be multiple per CPU.
  • Programs – Can be executed once, on a timer, on an event.

Program organization unit (POU)

  • Functions
    • Standard: ADD, SQRT, SIN, COS, GT, MIN, MAX, AND, OR, etc.
    • Custom
  • Function Blocks
    • Standard:
    • Custom – Libraries of functions can be supplied by a vendor or third party.
  • Programs

Configuration, resources, tasks

  • Configuration – processing resources, memory for IO, execution rates, number of tasks.

Object oriented programming (OOP)

  • The 3rd revision of the standard describes how to implement OOP within the application programming

References

  1. ^ Stevic, Tom (5 May 2017). "A very short history of PLC programming platforms". Control Design. Retrieved 11 September 2021.
  2. ^ "IEC 61131-3:2013". International Electrotechnical Commission (IEC). Retrieved 11 September 2021.
  3. ^ PLCopen: The third edition of IEC 61131-3
  4. ^ "Time Duration Literals (IEC 61131-3)".

External links

  • PLCopen
  • IEC 61131-3:2013 Programmable controllers - Part 3: Programming languages
  • CODESYS important implementation independent of device manufacturers, includes object oriented programming (OOP) as an option
  • de:STEP 7 implementation for Siemens devices, only

61131, this, article, relies, largely, entirely, single, source, relevant, discussion, found, talk, page, please, help, improve, this, article, introducing, citations, additional, sources, find, sources, news, newspapers, books, scholar, jstor, march, 2017, th. This article relies largely or entirely on a single source Relevant discussion may be found on the talk page Please help improve this article by introducing citations to additional sources Find sources IEC 61131 3 news newspapers books scholar JSTOR March 2017 IEC 61131 3is the third part of 10 of the open international standard IEC 61131 for programmable logic controllers It was first published in December 1993 1 by the IEC the current third edition was published in February 2013 2 Part 3 of IEC 61131 deals with basic software architecture and programming languages of the control program within PLC It defines three graphical and two textual programming language standards Ladder diagram LD graphical Function block diagram FBD graphical Structured text ST textual Instruction list IL textual deprecated in 3rd edition of the standard 3 Sequential function chart SFC has elements to organize programs for sequential and parallel control processing graphical Contents 1 Data types 2 Variables 3 Configuration 4 Program organization unit POU 5 Configuration resources tasks 6 Object oriented programming OOP 7 References 8 External linksData types EditElementary Data Type Bit Strings groups of on off values BOOL 1 bit 0 1 BYTE 8 bit 1 byte WORD 16 bit 2 byte DWORD 32 bit 4 byte LWORD 64 bit 8 byte INTEGER whole numbers Considering byte size 8 bits SINT signed short integer 1 byte INT signed integer 2 byte DINT signed double integer 4 byte LINT signed long integer 8 byte USINT Unsigned short integer 1 byte UINT Unsigned integer 2 byte UDINT Unsigned double integer 4 byte ULINT Unsigned long integer 8 byte REAL floating point IEC 60559 same as IEEE 754 2008 REAL 4 byte LREAL 8 byte Duration literals Unit Descriptiond Dayh Hourm Minutes Secondms Millisecondus Microsecondns NanosecondDuration 4 TIME 4 byte Literals in the form of T 5m90s15ms LTIME 8 byte Literals extend to nanoseconds in the form of T 5m90s15ms542us15ns Date DATE calendar date Size is not specified LDATE calendar date Size is not specified Time of day TIME OF DAY TOD clock time Size is not specified LTIME OF DAY LTOD clock time 8 byte Date and time of Day DATE AND TIME DT time and date Size is not specified LDATE AND TIME LDT time and date 8 byte Character Character string CHAR Single byte character 1 byte WCHAR Double byte character 2 byte STRING Variable length single byte character string Literals specified with single quote This is a STRING Literal WSTRING Variable length double byte character string Literals specified with a double quote This is a WSTRING Literal STRING escape sequences Escape sequence Produces L linefeed N newline P page form feed R return T tab xx hex valueGeneric Data Types Only available for the input output in out variables of system defined Program Organization Units POUs see below ANY ANY DERIVED ANY ELEMENTARY ANY MAGNITUDE ANY NUM ANY REAL LREAL REAL ANY INT ANY UNSIGNED ULINT UDINT UINT USINT ANY SIGNED LINT DINT INT SINT ANY DURATION TIME LTIME ANY BIT LWORD DWORD WORD BYTE BOOL ANY CHARS ANY STRING STRING WSTRING ANY CHAR CHAR WCHAR ANY DATE DATE AND TIME DT DATE AND TIME LDT DATE TIME OF DAY TOD LTIME OF DAY LTOD User defined Data Types Enumerated data type Enumerated data type with named value Subrange data type puts limits on value i e INT 4 20 for current Array data type multiple values stored in the same variable Structured data type composite of several variables and types Directly derived data type type derived from one of the above types to give new name and initial value as a type References a kind of strongly typed pointer Arithmetic operation of the value of this type is prohibited Variables EditVariable attributes RETAIN CONSTANT AT Global Direct local I O Mapping Input Output I O External TemporaryConfiguration EditResource Like a CPU Tasks Can be multiple per CPU Programs Can be executed once on a timer on an event Program organization unit POU EditFunctions Standard ADD SQRT SIN COS GT MIN MAX AND OR etc Custom Function Blocks Standard Custom Libraries of functions can be supplied by a vendor or third party ProgramsConfiguration resources tasks EditConfiguration processing resources memory for IO execution rates number of tasks Object oriented programming OOP EditThe 3rd revision of the standard describes how to implement OOP within the application programmingReferences Edit Stevic Tom 5 May 2017 A very short history of PLC programming platforms Control Design Retrieved 11 September 2021 IEC 61131 3 2013 International Electrotechnical Commission IEC Retrieved 11 September 2021 PLCopen The third edition of IEC 61131 3 Time Duration Literals IEC 61131 3 External links EditPLCopen IEC 61131 3 2013 Programmable controllers Part 3 Programming languages CODESYS important implementation independent of device manufacturers includes object oriented programming OOP as an option de STEP 7 implementation for Siemens devices only Retrieved from https en wikipedia org w index php title IEC 61131 3 amp oldid 1074875840, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.