fbpx
Wikipedia

Cryogenic Dark Matter Search

The Cryogenic Dark Matter Search (CDMS) is a series of experiments designed to directly detect particle dark matter in the form of Weakly Interacting Massive Particles (or WIMPs). Using an array of semiconductor detectors at millikelvin temperatures, CDMS has at times set the most sensitive limits on the interactions of WIMP dark matter with terrestrial materials (as of 2018, CDMS limits are not the most sensitive). The first experiment, CDMS I, was run in a tunnel under the Stanford University campus. It was followed by CDMS II experiment in the Soudan Mine. The most recent experiment, SuperCDMS (or SuperCDMS Soudan), was located deep underground in the Soudan Mine in northern Minnesota and collected data from 2011 through 2015. The series of experiments continues with SuperCDMS SNOLAB, an experiment located at the SNOLAB facility near Sudbury, Ontario in Canada that started construction in 2018 and is expected to start data taking in early 2020s.

Background edit

Observations of the large-scale structure of the universe show that matter is aggregated into very large structures that have not had time to form under the force of their own self-gravitation. It is generally believed that some form of missing mass is responsible for increasing the gravitational force at these scales, although this mass has not been directly observed. This is a problem; normal matter in space will heat up until it gives off light, so if this missing mass exists, it is generally assumed to be in a form that is not commonly observed on earth.

A number of proposed candidates for the missing mass have been put forward over time. Early candidates included heavy baryons that would have had to be created in the Big Bang, but more recent work on nucleosynthesis seems to have ruled most of these out.[1] Another candidate are new types of particles known as weakly interacting massive particles, or "WIMP"s. As the name implies, WIMPs interact weakly with normal matter, which explains why they are not easily visible.[1]

Detecting WIMPs thus presents a problem; if the WIMPs are very weakly interacting, detecting them will be extremely difficult. Detectors like CDMS and similar experiments measure huge numbers of interactions within their detector volume in order to find the extremely rare WIMP events.

Detection technology edit

The CDMS detectors measure the ionization and phonons produced by every particle interaction in their germanium and silicon crystal substrates.[1] These two measurements determine the energy deposited in the crystal in each interaction, but also give information about what kind of particle caused the event. The ratio of ionization signal to phonon signal differs for particle interactions with atomic electrons ("electron recoils") and atomic nuclei ("nuclear recoils"). The vast majority of background particle interactions are electron recoils, while WIMPs (and neutrons) are expected to produce nuclear recoils. This allows WIMP-scattering events to be identified even though they are rare compared to the vast majority of unwanted background interactions.

From supersymmetry, the probability of a spin-independent interaction between a WIMP and a nucleus would be related to the number of nucleons in the nucleus. Thus, a WIMP would be more likely to interact with a germanium detector than a silicon detector, since germanium is a much heavier element. Neutrons would be able to interact with both silicon and germanium detectors with similar probability. By comparing rates of interactions between silicon and germanium detectors, CDMS is able to determine the probability of interactions being caused by neutrons.

CDMS detectors are disks of germanium or silicon, cooled to millikelvin temperatures by a dilution refrigerator. The extremely low temperatures are needed to limit thermal noise which would otherwise obscure the phonon signals of particle interactions. Phonon detection is accomplished with superconduction transition edge sensors (TESs) read out by SQUID amplifiers, while ionization signals are read out using a FET amplifier. CDMS detectors also provide data on the phonon pulse shape which is crucial in rejecting near-surface background events.

History edit

Bolometric detection of neutrinos with semiconductors at low temperature was first proposed by Blas Cabrera, Lawrence M. Krauss, and Frank Wilczek,[2] and a similar method was proposed for WIMP detection by Mark Goodman and Edward Witten.[3]

CDMS I collected WIMP search data in a shallow underground site (called SUF) at Stanford University 1998–2002. CDMS II operated (with collaboration from the University of Minnesota) in the Soudan Mine from 2003 to 2009 (data taking 2006–2008).[4] The newest experiment, SuperCDMS (or SuperCDMS Soudan), with interleaved electrodes, more mass, and even better background rejection was taking data at Soudan 2011–2015. The series of experiments continue with SuperCDMS SNOLAB, currently (2018) under construction in SNOLAB and to be completed in the early 2020s.

The series of experiments also includes the CDMSlite experiment which used SuperCDMS detectors at Soudan in an operating mode (called CDMSlite-mode) that was meant to be sensitive specifically to low-mass WIMPs. As the CDMS-experiment has multiple different detector technologies in use, in particular, 2 types of detectors based on germanium or silicon, respectively, the experiments derived from some specific configuration of the CDMS-experiment detectors and different data-sets thus collected are sometimes given names like CDMS Ge, CDMS Si, CDMS II Si et cetera.

Results edit

On December 17, 2009, the collaboration announced the possible detection of two candidate WIMPs, one on August 8, 2007, and the other on October 27, 2007. Due to the low number of events, the team could exclude false positives from background noise such as neutron collisions. It is estimated that such noise would produce two or more events 25% of the time.[5] Polythene absorbers were fitted to reduce any neutron background.[6]

A 2011 analysis with lower energy thresholds, looked for evidence for low-mass WIMPs (M < 9 GeV). Their limits rule out hints claimed by a new germanium experiment called CoGeNT and the long-standing DAMA/NaI, DAMA/LIBRA annual modulation result.[7]

Further analysis of data in Physical Review Letters May 2013, revealed 3 WIMP detections with an expected background of 0.7, with masses expected from WIMPs, including neutralinos. There is a 0.19% chance that these are anomalous background noise, giving the result a 99.8% (3 sigmas) confidence level. Whilst not conclusive evidence for WIMPs this provides strong weight to the theories.[8] This signal was observed by the CDMS II-experiment and it is called the CDMS Si-signal (sometimes the experiment is also called CDMS Si) because it was observed by the silicon detectors.

SuperCDMS search results from October 2012 to June 2013 were published in June 2014, finding 11 events in the signal region for WIMP mass less than 30 GeV, and set an upper limit for spin-independent cross section disfavoring a recent CoGeNT low mass signal.[9]

SuperCDMS SNOLAB edit

A second generation of SuperCDMS is planned for SNOLAB.[10][11] This is expanded from SuperCDMS Soudan in every way:

  • The individual detector discs are 100 mm/3.9″ diameter × 33.3 mm/1.3″ thick, 225% the volume of the 76.2 mm/3″ diameter × 25.4 mm/1″ thick discs in Soudan.[10][11]
  • There are more of them, with room for 31 "towers" of six discs each,[12]: 7  although operation will begin with only four towers.
  • The detector is better shielded, by both its deeper location in SNOLAB, and greater attention to radiopurity in construction.[13]: 18 

The increase in detector mass is not quite as large, because about 25% of the detectors will be made of silicon,[12]: 7  which only weights 44% as much.[14]: 1  Filling all 31 towers at this ratio would result in about 222 kg

Although the project has suffered repeated delays (earlier plans hoped for construction to begin in 2014[15] and 2016[13]: 18–25 ), it remains active,[14] with space allocated in SNOLAB and a scheduled construction start in early 2018.[10]: 9 

The construction of SuperCDMS at SNOLAB started in 2018 with beginning of operations in early 2020s. The project budget at the time was US$34 million.[16]

In May 2021, the SuperCDMS SNOLAB detector was under construction, with early science (or prototyping, or preliminary studies) ongoing with prorotype/testing hardware, both at the SNOLAB location and at other locations. The full detector was expected ready for science data taking at the end of 2023, and the science operations to last 4 years (with two separate runs) 2023-2027, with possible extensions and developments beyond 2027.[17]

GEODM proposal edit

A third generation of SuperCDMS is envisioned,[10] although still in the early planning phase. GEODM (Germanium Observatory for Dark Matter), with roughly 1500 kg of detector mass, has expressed interest in the SNOLAB "Cryopit" location.[18]

Increasing the detector mass only makes the detector more sensitive if the unwanted background detections do not increase as well, thus each generation must be cleaner and better shielded than the one before. The purpose of building in ten-fold stages like this is to develop the necessary shielding techniques before finalizing the GEODM design.

References edit

  1. ^ a b c "WIMP Dark Matter" 2002-06-01 at the Wayback Machine, CDMSII Overview, University of California, Berkeley
  2. ^ B. Cabrera; L.M. Krauss; F. Wilczek (July 1985), "Bolometric detection of neutrinos", Phys. Rev. Lett., 55 (1): 25–28, Bibcode:1985PhRvL..55...25C, doi:10.1103/PhysRevLett.55.25, PMID 10031671
  3. ^ M.W. Goodman; E. Witten (15 June 1985), "Detectability of certain dark matter candidates", Phys. Rev. D, 31 (12): 3059–3063, Bibcode:1985PhRvD..31.3059G, doi:10.1103/PhysRevD.31.3059, PMID 9955633
  4. ^ Ananthaswamy, Anil (2010-03-02). The Edge of Physics: A Journey to Earth's Extremes to Unlock the Secrets of the Universe. HMH. ISBN 978-0-547-48846-2.
  5. ^ "Latest Results in the Search for Dark Matter Thursday, December 17, 2009" June 18, 2010, at the Wayback Machine
  6. ^ . Archived from the original on 2000-08-18. Retrieved 2011-09-23.
  7. ^ CDMS Collaboration (21 Apr 2011). "Results from a Low-Energy Analysis of the CDMS II Germanium Data". Physical Review Letters. 106 (13): 131302. arXiv:1011.2482. Bibcode:2011PhRvL.106m1302A. doi:10.1103/PhysRevLett.106.131302. PMID 21517371. S2CID 9879642.
  8. ^ CDMS Collaboration (4 May 2013). "Dark Matter Search Results Using the Silicon Detectors of CDMS II". Physical Review Letters. 111 (25): 251301. arXiv:1304.4279. Bibcode:2013PhRvL.111y1301A. doi:10.1103/PhysRevLett.111.251301. PMID 24483735. S2CID 3073653.
  9. ^ Agnese, R.; Anderson, A. J.; Asai, M.; Balakishiyeva, D.; Basu Thakur, R.; Bauer, D. A.; Beaty, J.; Billard, J.; Borgland, A.; Bowles, M. A.; Brandt, D.; Brink, P. L.; Bunker, R.; Cabrera, B.; Caldwell, D. O.; Cerdeno, D. G.; Chagani, H.; Chen, Y.; Cherry, M.; Cooley, J.; Cornell, B.; Crewdson, C. H.; Cushman, P.; Daal, M.; Devaney, D.; Di Stefano, P. C. F.; Silva, E. Do Couto E.; Doughty, T.; Esteban, L.; et al. (June 20, 2014). "Search for Low-Mass WIMPs with SuperCDMS". Phys. Rev. Lett. 112 (24): 241302. arXiv:1402.7137. Bibcode:2014PhRvL.112x1302A. doi:10.1103/PhysRevLett.112.241302. hdl:1721.1/88645. PMID 24996080. S2CID 119066853.
  10. ^ a b c d Cushman, Priscilla (2012-07-22), "The Cryogenic Dark Matter Search: Status and Future Plans" (PDF), IDM Conference
  11. ^ a b Saab, Tarek (2012-08-01), "The SuperCDMS Dark Matter Search" (PDF), SLAC Summer Institute 2012, SLAC National Accelerator Laboratory, retrieved 2012-11-28 (presentation)
  12. ^ a b Rau, Wolfgang (25 July 2017). SuperCDMS SNOLAB—Status and Plans. XV International Conference on Topics in Astroparticle and Underground Physics (TAUP 2017). Sudbury, Canada.
  13. ^ a b Brink, Paul (25 June 2015). SuperCDMS results and plans for SNOLAB. 11th Patras Workshop on Axions, WIMPs and WISPs. Zaragoza, Spain.
  14. ^ a b Agnese, R.; et al. (SuperCDMS Collaboration) (2017-04-07). "Projected sensitivity of the SuperCDMS SNOLAB experiment" (PDF). Physical Review D. 95 (8): 082002. arXiv:1610.00006. Bibcode:2017PhRvD..95h2002A. doi:10.1103/PhysRevD.95.082002. hdl:1721.1/109800. S2CID 32272925.
  15. ^ (Press release). SNOLAB. 2014-07-18. Archived from the original on 2019-03-30. Retrieved 2014-09-18.
  16. ^ "Construction Begins on SuperCDMS Dark Matter Experiment".
  17. ^ https://indico.cern.ch/event/987061/contributions/4284117/attachments/2242134/3801781/210510SuperCDMS_SNOLAB_FPW_v1_web.pdf[bare URL PDF]
  18. ^ Golwala, Sunil (2011-08-15). GEODM Interest in the SNOLAB Cryopit (PDF).

External links edit

  • SuperCDMS web site

cryogenic, dark, matter, search, cdms, series, experiments, designed, directly, detect, particle, dark, matter, form, weakly, interacting, massive, particles, wimps, using, array, semiconductor, detectors, millikelvin, temperatures, cdms, times, most, sensitiv. The Cryogenic Dark Matter Search CDMS is a series of experiments designed to directly detect particle dark matter in the form of Weakly Interacting Massive Particles or WIMPs Using an array of semiconductor detectors at millikelvin temperatures CDMS has at times set the most sensitive limits on the interactions of WIMP dark matter with terrestrial materials as of 2018 CDMS limits are not the most sensitive The first experiment CDMS I was run in a tunnel under the Stanford University campus It was followed by CDMS II experiment in the Soudan Mine The most recent experiment SuperCDMS or SuperCDMS Soudan was located deep underground in the Soudan Mine in northern Minnesota and collected data from 2011 through 2015 The series of experiments continues with SuperCDMS SNOLAB an experiment located at the SNOLAB facility near Sudbury Ontario in Canada that started construction in 2018 and is expected to start data taking in early 2020s Contents 1 Background 2 Detection technology 3 History 3 1 Results 4 SuperCDMS SNOLAB 5 GEODM proposal 6 References 7 External linksBackground editObservations of the large scale structure of the universe show that matter is aggregated into very large structures that have not had time to form under the force of their own self gravitation It is generally believed that some form of missing mass is responsible for increasing the gravitational force at these scales although this mass has not been directly observed This is a problem normal matter in space will heat up until it gives off light so if this missing mass exists it is generally assumed to be in a form that is not commonly observed on earth A number of proposed candidates for the missing mass have been put forward over time Early candidates included heavy baryons that would have had to be created in the Big Bang but more recent work on nucleosynthesis seems to have ruled most of these out 1 Another candidate are new types of particles known as weakly interacting massive particles or WIMP s As the name implies WIMPs interact weakly with normal matter which explains why they are not easily visible 1 Detecting WIMPs thus presents a problem if the WIMPs are very weakly interacting detecting them will be extremely difficult Detectors like CDMS and similar experiments measure huge numbers of interactions within their detector volume in order to find the extremely rare WIMP events Detection technology editSee also Cryogenic particle detector The CDMS detectors measure the ionization and phonons produced by every particle interaction in their germanium and silicon crystal substrates 1 These two measurements determine the energy deposited in the crystal in each interaction but also give information about what kind of particle caused the event The ratio of ionization signal to phonon signal differs for particle interactions with atomic electrons electron recoils and atomic nuclei nuclear recoils The vast majority of background particle interactions are electron recoils while WIMPs and neutrons are expected to produce nuclear recoils This allows WIMP scattering events to be identified even though they are rare compared to the vast majority of unwanted background interactions From supersymmetry the probability of a spin independent interaction between a WIMP and a nucleus would be related to the number of nucleons in the nucleus Thus a WIMP would be more likely to interact with a germanium detector than a silicon detector since germanium is a much heavier element Neutrons would be able to interact with both silicon and germanium detectors with similar probability By comparing rates of interactions between silicon and germanium detectors CDMS is able to determine the probability of interactions being caused by neutrons CDMS detectors are disks of germanium or silicon cooled to millikelvin temperatures by a dilution refrigerator The extremely low temperatures are needed to limit thermal noise which would otherwise obscure the phonon signals of particle interactions Phonon detection is accomplished with superconduction transition edge sensors TESs read out by SQUID amplifiers while ionization signals are read out using a FET amplifier CDMS detectors also provide data on the phonon pulse shape which is crucial in rejecting near surface background events History editBolometric detection of neutrinos with semiconductors at low temperature was first proposed by Blas Cabrera Lawrence M Krauss and Frank Wilczek 2 and a similar method was proposed for WIMP detection by Mark Goodman and Edward Witten 3 CDMS I collected WIMP search data in a shallow underground site called SUF at Stanford University 1998 2002 CDMS II operated with collaboration from the University of Minnesota in the Soudan Mine from 2003 to 2009 data taking 2006 2008 4 The newest experiment SuperCDMS or SuperCDMS Soudan with interleaved electrodes more mass and even better background rejection was taking data at Soudan 2011 2015 The series of experiments continue with SuperCDMS SNOLAB currently 2018 under construction in SNOLAB and to be completed in the early 2020s The series of experiments also includes the CDMSlite experiment which used SuperCDMS detectors at Soudan in an operating mode called CDMSlite mode that was meant to be sensitive specifically to low mass WIMPs As the CDMS experiment has multiple different detector technologies in use in particular 2 types of detectors based on germanium or silicon respectively the experiments derived from some specific configuration of the CDMS experiment detectors and different data sets thus collected are sometimes given names like CDMS Ge CDMS Si CDMS II Si et cetera Results edit On December 17 2009 the collaboration announced the possible detection of two candidate WIMPs one on August 8 2007 and the other on October 27 2007 Due to the low number of events the team could exclude false positives from background noise such as neutron collisions It is estimated that such noise would produce two or more events 25 of the time 5 Polythene absorbers were fitted to reduce any neutron background 6 A 2011 analysis with lower energy thresholds looked for evidence for low mass WIMPs M lt 9 GeV Their limits rule out hints claimed by a new germanium experiment called CoGeNT and the long standing DAMA NaI DAMA LIBRA annual modulation result 7 Further analysis of data in Physical Review Letters May 2013 revealed 3 WIMP detections with an expected background of 0 7 with masses expected from WIMPs including neutralinos There is a 0 19 chance that these are anomalous background noise giving the result a 99 8 3 sigmas confidence level Whilst not conclusive evidence for WIMPs this provides strong weight to the theories 8 This signal was observed by the CDMS II experiment and it is called the CDMS Si signal sometimes the experiment is also called CDMS Si because it was observed by the silicon detectors SuperCDMS search results from October 2012 to June 2013 were published in June 2014 finding 11 events in the signal region for WIMP mass less than 30 GeV and set an upper limit for spin independent cross section disfavoring a recent CoGeNT low mass signal 9 SuperCDMS SNOLAB editA second generation of SuperCDMS is planned for SNOLAB 10 11 This is expanded from SuperCDMS Soudan in every way The individual detector discs are 100 mm 3 9 diameter 33 3 mm 1 3 thick 225 the volume of the 76 2 mm 3 diameter 25 4 mm 1 thick discs in Soudan 10 11 There are more of them with room for 31 towers of six discs each 12 7 although operation will begin with only four towers The detector is better shielded by both its deeper location in SNOLAB and greater attention to radiopurity in construction 13 18 The increase in detector mass is not quite as large because about 25 of the detectors will be made of silicon 12 7 which only weights 44 as much 14 1 Filling all 31 towers at this ratio would result in about 222 kgAlthough the project has suffered repeated delays earlier plans hoped for construction to begin in 2014 15 and 2016 13 18 25 it remains active 14 with space allocated in SNOLAB and a scheduled construction start in early 2018 10 9 The construction of SuperCDMS at SNOLAB started in 2018 with beginning of operations in early 2020s The project budget at the time was US 34 million 16 In May 2021 the SuperCDMS SNOLAB detector was under construction with early science or prototyping or preliminary studies ongoing with prorotype testing hardware both at the SNOLAB location and at other locations The full detector was expected ready for science data taking at the end of 2023 and the science operations to last 4 years with two separate runs 2023 2027 with possible extensions and developments beyond 2027 17 GEODM proposal editA third generation of SuperCDMS is envisioned 10 although still in the early planning phase GEODM Germanium Observatory for Dark Matter with roughly 1500 kg of detector mass has expressed interest in the SNOLAB Cryopit location 18 Increasing the detector mass only makes the detector more sensitive if the unwanted background detections do not increase as well thus each generation must be cleaner and better shielded than the one before The purpose of building in ten fold stages like this is to develop the necessary shielding techniques before finalizing the GEODM design References edit a b c WIMP Dark Matter Archived 2002 06 01 at the Wayback Machine CDMSII Overview University of California Berkeley B Cabrera L M Krauss F Wilczek July 1985 Bolometric detection of neutrinos Phys Rev Lett 55 1 25 28 Bibcode 1985PhRvL 55 25C doi 10 1103 PhysRevLett 55 25 PMID 10031671 M W Goodman E Witten 15 June 1985 Detectability of certain dark matter candidates Phys Rev D 31 12 3059 3063 Bibcode 1985PhRvD 31 3059G doi 10 1103 PhysRevD 31 3059 PMID 9955633 Ananthaswamy Anil 2010 03 02 The Edge of Physics A Journey to Earth s Extremes to Unlock the Secrets of the Universe HMH ISBN 978 0 547 48846 2 Latest Results in the Search for Dark Matter Thursday December 17 2009 Archived June 18 2010 at the Wayback Machine CDMS cryostat without detectors Archived from the original on 2000 08 18 Retrieved 2011 09 23 CDMS Collaboration 21 Apr 2011 Results from a Low Energy Analysis of the CDMS II Germanium Data Physical Review Letters 106 13 131302 arXiv 1011 2482 Bibcode 2011PhRvL 106m1302A doi 10 1103 PhysRevLett 106 131302 PMID 21517371 S2CID 9879642 CDMS Collaboration 4 May 2013 Dark Matter Search Results Using the Silicon Detectors of CDMS II Physical Review Letters 111 25 251301 arXiv 1304 4279 Bibcode 2013PhRvL 111y1301A doi 10 1103 PhysRevLett 111 251301 PMID 24483735 S2CID 3073653 Agnese R Anderson A J Asai M Balakishiyeva D Basu Thakur R Bauer D A Beaty J Billard J Borgland A Bowles M A Brandt D Brink P L Bunker R Cabrera B Caldwell D O Cerdeno D G Chagani H Chen Y Cherry M Cooley J Cornell B Crewdson C H Cushman P Daal M Devaney D Di Stefano P C F Silva E Do Couto E Doughty T Esteban L et al June 20 2014 Search for Low Mass WIMPs with SuperCDMS Phys Rev Lett 112 24 241302 arXiv 1402 7137 Bibcode 2014PhRvL 112x1302A doi 10 1103 PhysRevLett 112 241302 hdl 1721 1 88645 PMID 24996080 S2CID 119066853 a b c d Cushman Priscilla 2012 07 22 The Cryogenic Dark Matter Search Status and Future Plans PDF IDM Conference a b Saab Tarek 2012 08 01 The SuperCDMS Dark Matter Search PDF SLAC Summer Institute 2012 SLAC National Accelerator Laboratory retrieved 2012 11 28 presentation a b Rau Wolfgang 25 July 2017 SuperCDMS SNOLAB Status and Plans XV International Conference on Topics in Astroparticle and Underground Physics TAUP 2017 Sudbury Canada a b Brink Paul 25 June 2015 SuperCDMS results and plans for SNOLAB 11th Patras Workshop on Axions WIMPs and WISPs Zaragoza Spain a b Agnese R et al SuperCDMS Collaboration 2017 04 07 Projected sensitivity of the SuperCDMS SNOLAB experiment PDF Physical Review D 95 8 082002 arXiv 1610 00006 Bibcode 2017PhRvD 95h2002A doi 10 1103 PhysRevD 95 082002 hdl 1721 1 109800 S2CID 32272925 Second generation dark matter experiment coming to SNOLAB Press release SNOLAB 2014 07 18 Archived from the original on 2019 03 30 Retrieved 2014 09 18 Construction Begins on SuperCDMS Dark Matter Experiment https indico cern ch event 987061 contributions 4284117 attachments 2242134 3801781 210510SuperCDMS SNOLAB FPW v1 web pdf bare URL PDF Golwala Sunil 2011 08 15 GEODM Interest in the SNOLAB Cryopit PDF External links editSuperCDMS web site Retrieved from https en wikipedia org w index php title Cryogenic Dark Matter Search amp oldid 1150428584, wikipedia, wiki, book, books, library,