Rebreather

A rebreather is a breathing apparatus that absorbs the carbon dioxide of a user's exhaled breath to permit the rebreathing (recycling) of the substantially unused oxygen content, and unused inert content when present, of each breath. Oxygen is added to replenish the amount metabolised by the user. This differs from open-circuit breathing apparatus, where the exhaled gas is discharged directly into the environment. The purpose is to extend the breathing endurance of a limited gas supply, and, for covert military use by frogmen or observation of underwater life, eliminating the bubbles produced by an open circuit system and in turn not scaring wildlife being filmed. A rebreather is generally understood to be a portable unit carried by the user. The same technology on a vehicle or non-mobile installation is more likely to be referred to as a life-support system.

Rebreather
A fully closed circuit electronic rebreather (AP Diving Inspiration)
AcronymCCUBA (closed circuit underwater breathing apparatus); CCR (closed circuit rebreather), SCR (semi-closed rebreather)
UsesBreathing set
Related itemsDavis apparatus, Self-contained breathing apparatus, Escape hood

Rebreather technology may be used where breathing gas supply is limited, such as underwater, in space, where the environment is toxic or hypoxic (as in firefighting), mine rescue, high-altitude operations, or where the breathing gas is specially enriched or contains expensive components, such as helium diluent or anaesthetic gases.

Rebreathers are used in many environments: Underwater, diving rebreathers are a type of self-contained underwater breathing apparatus which have provisions for both a primary and emergency gas supply. On land they are used in industrial applications where poisonous gases may be present or oxygen may be absent, firefighting, where firefighters may be required to operate in an atmosphere immediately dangerous to life and health for extended periods, in hospital anaesthesia breathing systems to supply controlled concentrations of anaesthetic gases to patients without contaminating the air that the staff breathe, and at high altitude, where the partial pressure of oxygen is low, for high altitude mountaineering. In aerospace there are applications in unpressurised aircraft and for high altitude parachute drops, and above the Earth's atmosphere, in space suits for extra-vehicular activity. Similar technology is used in life-support systems in submarines, submersibles, atmospheric diving suits, underwater and surface saturation habitats, spacecraft, and space stations, and in gas reclaim systems used to recover the large volumes of helium used in saturation diving.

The recycling of breathing gas comes at the cost of technological complexity and specific hazards, some of which depend on the application and type of rebreather used. Mass and bulk may be greater or less than open circuit depending on circumstances. Electronically controlled diving rebreathers may automatically maintain a partial pressure of oxygen between programmable upper and lower limits, or set points, and be integrated with decompression computers to monitor the decompression status of the diver and record the dive profile.

General concept edit

As a person breathes, the body consumes oxygen and produces carbon dioxide. Base metabolism requires about 0.25 L/min of oxygen from a breathing rate of about 6 L/min, and a fit person working hard may ventilate at a rate of 95 L/min but will only metabolise about 4 L/min of oxygen [1] The oxygen metabolised is generally about 4% to 5% of the inspired volume at normal atmospheric pressure, or about 20% of the available oxygen in the air at sea level. Exhaled air at sea level contains roughly 13.5% to 16% oxygen.[2]

The situation is even more wasteful of oxygen when the oxygen fraction of the breathing gas is higher, and in underwater diving, the compression of breathing gas due to depth makes the recirculation of exhaled gas even more desirable, as an even larger proportion of open circuit gas is wasted. Continued rebreathing of the same gas will deplete the oxygen to a level which will no longer support consciousness, and eventually life, so gas containing oxygen must be added to the breathing gas to maintain the required concentration of oxygen.[3]

However, if this is done without removing the carbon dioxide, it will rapidly build up in the recycled gas, resulting almost immediately in mild respiratory distress, and rapidly developing into further stages of hypercapnia, or carbon dioxide toxicity. A high ventilation rate is usually necessary to eliminate the metabolic product carbon dioxide (CO2). The breathing reflex is triggered by CO2 concentration in the blood, not by the oxygen concentration, so even a small buildup of CO2 in the inhaled gas quickly becomes intolerable; if a person tries to directly rebreathe their exhaled breathing gas, they will soon feel an acute sense of suffocation, so rebreathers must remove the CO2 in a component known as a carbon dioxide scrubber.[4]

By adding sufficient oxygen to compensate for the metabolic usage, removing the carbon dioxide, and rebreathing the gas, most of the volume is conserved.[4]

 
Relation of physiological effects to carbon dioxide concentration and exposure period.[5]
Effects of different levels of oxygen partial pressure[1]
PO2
(bar)
Application and effect
<0.08 Coma ultimately leading to death
0.08-0.10 Unconsciousness in most people
0.09-0.10 Serious signs/symptoms of hypoxia
0.14-0.16 Initial signs/symptoms of hypoxia (normal environment oxygen in some very high altitude areas)
0.21 Normal environment oxygen (sea level air)
0.35–0.40 Normal saturation dive PO2 level
0.50 Threshold for whole-body effects; maximum saturation dive exposure
1.0–1.20 Common range for recreational closed circuit set point
1.40 Recommended limit for recreational open circuit bottom sector
1.60 NOAA limit for maximum exposure for a working diver
Recreational/technical limit for decompression
2.20 Commercial/military "Sur-D" chamber surface decompression on 100% O2 at 12 msw (meters of sea water)
2.40 40% O2 nitrox recompression treatment gas for use in the chamber at 50 msw
2.80 100% O2 recompression treatment gas for use in the chamber at 18 msw
3.00 50% O2 nitrox recompression treatment gas for use in the chamber at 50 msw

Architecture edit

 
Comparison of pendulum and loop rebreather architecture
  • 1 Mouthpiece with dive/surface valve
  • 2 Two way breathing hose
  • 2a Exhalation hose with non-return valve
  • 2b Inhalation hose with non-return valve
  • 3 Scrubber
  • 4 Counterlung
  • 5 Automatic make-up valve
  • 6 Manual bypass valve
  • 7 Breathing gas storage cylinder
  • 8 Cylinder valve
  • 9 Regulator first stage
  • 10 Cylinder pressure gauge
  • 11 Over-pressure valve

There are two basic arrangements controlling the flow of breathing gas inside the rebreather, known as the pendulum and loop systems.

Pendulum edit

In the pendulum configuration, the user inhales gas from the counterlung through a breathing hose, and exhaled gas returns to the counter lung by flowing back through the same hose. The scrubber is usually between the breathing hose and the counterlung bag, and gas flow is bi-directional. All of the flow passages between the user and the active absorbent in the scrubber are dead space – volume containing gas which is rebreathed without modification by the rebreather. The dead space increases as the absorbent is depleted. Breathing hose volume must be minimised to limit dead space.

Loop edit

In the loop configuration, the user inhales gas through one hose, and exhales through a second hose. Exhaled gas flows into the scrubber from one side, and exits at the other side. There may be one large counterlung, on either side of the scrubber, or two smaller counterlungs, one on each side of the scrubber. Flow is in one direction, enforced by non-return valves, which are usually in the breathing hoses where they join the mouthpiece. Only the flow passage in the mouthpiece before the split between inhalation and exhalation hoses is dead space, and this is not affected by hose volume.[6]

Components edit

 
Oxygen rebreather KIP-8 interior showing the basic components
 
Russian firefighting rebreather KIP-8 exterior

There are some components that are common to almost all personal portable rebreathers. These include the ambient pressure breathing volume components, usually called the breathing loop in a circulating flow rebreather, and the make-up gas supply and control system.

Counterlung edit

The counterlung is an airtight bag of strong flexible material that holds the volume of the exhaled gas until it is inhaled again. There may be a single counterlung, or one on each side of the scrubber, which allows a more even flow rate of gas through the scrubber, which can reduce work of breathing and improve scrubber efficiency by a more consistent dwell time.

Scrubber edit

The scrubber is a container that has an inlet on one side and an outlet on the other side, filled with carbon dioxide absorbent material, mostly strong bases, through which the exhaled gas passes to remove the carbon dioxide. The absorbent may be granular or in the form of a moulded cartridge.[7] Granular sorb may be manufactured by breaking up lumps of lime and sorting the granules by size, or by moulding granules at a consistent size and shape.[8] Gas flow through the scrubber may be in one direction in a loop rebreather, or both ways in a pendulum rebreather.

A typical absorbent is Sodalime, which is made up of calcium hydroxide Ca(OH)2, and potassium hydroxide KOH, or sodium hydroxide NaOH (Either or both of these may be present). The main component of soda lime is calcium hydroxide, which is relatively cheap and easily available. Other components may be present in the absorbent. Sodium hydroxide is added to accelerate the reaction with carbon dioxide. Other chemicals may be added to prevent unwanted decomposition products when used with standard halogenated inhalation anaesthetics. An indicator may be included to show when carbon dioxide has dissolved in the water of the soda lime and formed carbonic acid, changing the pH from basic to acid, as the change of colour shows that the absorbent has reached saturation with carbon dioxide and must be changed.[8]

The carbon dioxide combines with water or water vapor to produce a weak carbonic acid: CO2 + H2O –> H2CO3. This reacts with the hydroxides to produce carbonates and water in an exothermic reaction:[6] In the intermediate reaction, the carbonic acid reacts exothermically with sodium hydroxide to form sodium carbonate and water: H2CO3 + 2NaOH –> Na2CO3 + 2H2O + heat. In the final reaction, the sodium carbonate reacts with the slaked lime (calcium hydroxide) to form calcium carbonate and sodium hydroxide: Na2CO3 + Ca(OH)2 –> CaCO3 + 2NaOH. The sodium hydroxide is then available again to react with more carbonic acid.[8] 100 grams (3.5 oz) of this absorbent can remove about 15 to 25 litres (0.53 to 0.88 cu ft) of carbon dioxide at standard atmospheric pressure[6][8] This process also heats and humidifies the air, which is desirable for diving in cold water, or climbing at high altitudes, but not for working in hot environments.

Other reactions may be used in special circumstances. Lithium hydroxide and particularly lithium peroxide may be used where low mass is important, such as in space stations and space suits. Lithium peroxide also replenishes the oxygen during the scrubbing reaction.[9]

Another method of carbon dioxide removal occasionally used in portable rebreathers is to freeze it out, which is possible in a cryogenic rebreather which uses liquid oxygen. The liquid oxygen absorbs heat from the carbon dioxide in a heat exchanger to convert the oxygen to gas, which is sufficient to freeze the carbon dioxide. This process also chills the gas, which is sometimes, but not always, desirable.

Breathing hoses edit

 
Draeger Ray dive/surface valve with bite grip scuba mouthpiece, non-return valves, and breathing hoses

A breathing hose or sometimes breathing tube on a rebreather is a flexible tube for breathing gas to pass through at ambient pressure. They are distinguished from the low-, intermediate-, and high-pressure hoses which may also be parts of rebreather apparatus. They have a wide enough bore to minimise flow resistance at the ambient pressure in the operational range for the equipment, are usually circular in cross section, and may be corrugated to let the user's head move about without the tube collapsing at kinks.[6]

Each end has an airtight connection to the adjacent component, and they may contain a one-way valve to keep the gas circulating the right way in a loop system. Depending on the service, they may be made of a flexible polymer, an elastomer, a fibre or cloth reinforced elastomer, or elastomer covered with a woven fabric for reinforcement or abrasion resistance. If the woven layer is bonded to the outside surface it protects the rubber from damage from scrapes but makes it more difficult to wash off contaminants.[6]

Breathing hoses are usually long enough to connect the apparatus to the user's head in all attitudes of their head, but should not be unnecessarily long, which will cause additional weight, hydrodynamic drag, risk snagging on things, or contain excess dead space in a pendulum rebreather. Breathing hoses can be tethered down to a diver's shoulders or ballasted for neutral buoyancy to minimise loads on the mouthpiece.

Mouthpiece or facemask edit

A mouthpiece with bite-grip, an oro-nasal mask, a full-face mask, or a sealed helmet is provided so that the user can breathe from the unit hands-free.

Oxygen supply edit

A store of oxygen, usually in a high pressure cylinder, but sometimes as liquid oxygen, that feeds gaseous oxygen into the ambient pressure breathing volume, either continuously, or when the user operates the oxygen addition valve, or via a demand valve in an oxygen rebreather, when the volume of gas in the breathing circuit becomes low and the pressure drops, or in an electronically controlled mixed gas rebreather, after a sensor has detected insufficient oxygen partial pressure, and activates a solenoid valve.

Valves edit

Valves are needed to control gas flow in the breathing volume, and gas feed from the storage container. They include:

  • Non-return valves in the breathing loop of loop rebreathers, which enforce one-directional flow to minimise dead space,
  • Dive/surface valves on diving rebreathers, which prevent water from entering the breathing volume when the mouthpiece is removed, or the user elects to breathe ambient air at the surface.
  • Gas supply valves, including a cylinder valve, to allow high pressure gas to flow from the cylinder. This may be manually operated by the user to directly supply make-up gas, or may provide the gas to a pressure regulator which reduces the pressure to a few bar above ambient pressure, and supplies this intermediate pressure gas to the gas feed system, which may contain one or more of:
    • Manually operated feed valve,
    • Constant mass flow orifice or needle valve, to provide a continuous feed,
    • Demand valve which automatically adds gas when the volume of the counterlung(s) is too low, and pressure in the breathing volume drops below ambient pressure.
  • Overpressure valve, to release excess gas. This is mainly used in diving rebreathers to compensate for expansion during ascent. Excess gas may also be vented past the skirt seal of a full-face mask, or through the nose when a mouthpiece is used.

Oxygen sensors edit

Oxygen sensors may be used to monitor partial pressure of oxygen in mixed gas rebreathers to ensure that it does not fall outside the safe limits, but are generally not used on oxygen rebreathers, as the oxygen content is fixed at 100%, and its partial pressure varies only with the ambient pressure.

System variants edit

Rebreathers can be primarily categorised as diving rebreathers, intended for hyperbaric use, and other rebreathers used at pressures from slightly more than normal atmospheric pressure at sea level to significantly lower ambient pressure at high altitudes and in space. Diving rebreathers must often deal with the complications of avoiding hyperbaric oxygen toxicity, while normobaric and hypobaric applications can use the relatively trivially simple oxygen rebreather technology, where there is no requirement to monitor oxygen partial pressure during use providing the ambient pressure is sufficient.

Oxygen rebreathers edit

 
Siebe Gorman Proto 1 mine rescue rebreather, a simple oxygen rebreather.

This is the earliest type of rebreather and was commonly used by navies for submarine escape and shallow water diving work, for mine rescue, high altitude mountaineering and flight, and in industrial applications from the early twentieth century. Oxygen rebreathers can be remarkably simple and mechanically reliable, and they were invented before open-circuit scuba. They only supply oxygen, so there is no requirement to control the gas composition other than removing the carbon dioxide.[10]

Oxygen feed options edit

In some rebreathers the oxygen cylinder has oxygen supply mechanisms in parallel. One is constant flow; the other is a manual on-off valve called a bypass valve; both feed into the same hose which feeds the counterlung.[11] Others are supplied via a demand valve on the counterlung. This will add gas at any time that the counterlung is emptied and the diver continues to inhale. Oxygen can also be added manually by a button which activates the demand valve.[12] Some simple oxygen rebreathers had no automatic supply system, but only the manual feed valve, and the diver had to operate the valve at intervals to refill the breathing bag as the volume of oxygen decreased below a comfortable level.

Mixed gas rebreathers edit

 
Mixed gas electronically controlled closed circuit diving rebreather

All rebreathers other than oxygen rebreathers may be considered mixed gas rebreathers, as the breathing gas is a mixture of oxygen and metabolically inactive diluent gas. These can be divided into semi-closed circuit, where the supply gas is a breathable mixture containing oxygen and inert diluents, usually nitrogen and helium, and which is replenished by adding more of the mixture as the oxygen is used up, sufficient to maintain a breathable partial pressure of oxygen in the loop, and closed circuit rebreathers, where two parallel gas supplies are used: the diluent, to provide the bulk of the gas, and which is recycled, and oxygen, which is metabolically expended. Carbon dioxide is considered a waste product, and in a correctly functioning rebreather, is effectively removed when the gas passes through the scrubber.

Rebreathers using an absorbent that releases oxygen edit

 
Russian multipurpose rebreather IDA-71 with lid of casing opened showing interior – one of the scrubber canisters can optionally be filled with superoxide.

There have been a few rebreather designs (e.g. the Oxylite) which use potassium superoxide, which gives off oxygen as it absorbs carbon dioxide, as the carbon dioxide absorbent: 4KO2 + 2CO2 = 2K2CO3 + 3O2. A small volume oxygen cylinder is needed to fill and purge the loop at the start of use.[13] This technology may be applied to both oxygen and mixed gas rebreathers, and can be used for diving and other applications. Potassium superoxide reacts vigorously with liquid water, releasing considerable heat and oxygen,and causing a fire hazard, so the more successful applications have been for space-suits, fire-fighting and mine rescue.[14]

Rebreathers which use liquid oxygen edit

 
Aerorlox liquid oxygen rebreather in a coal mining museum

A liquid oxygen supply can be used for oxygen or mixed gas rebreathers. If used underwater, the liquid-oxygen container must be well insulated against heat transfer from the water. Industrial sets of this type may not be suitable for diving, and diving sets of this type may not be suitable for use out of water due to conflicting heat transfer requirements. The set's liquid oxygen tank must be filled immediately before use. Examples of the type include:

Cryogenic rebreather edit

A cryogenic rebreather removes the carbon dioxide by freezing it out in a "snow box" by the low temperature produced as liquid oxygen evaporates to replace the oxygen used.

Fields of application edit

This may be compared with some applications of open-circuit breathing apparatus:

  • The oxygen enrichment systems primarily used by medical patients, high altitude mountaineers and commercial aircraft emergency systems, in which the user breathes ambient air which is enriched by the addition of pure oxygen,
  • Open circuit breathing apparatus used by firefighters, underwater divers and some mountaineers, which supplies fresh gas for each breath, which is then discharged into the environment.
  • Gas masks and respirators which filter contaminants from ambient air which is then breathed.

Diving rebreathers edit

 
SIVA Underwater Mine Countermeasures (MCM) Diving Apparatus (oxygen rebreather)

The widest variety of rebreather types is used in diving, as the consequences of breathing under pressure complicate the requirements, and a large range of options are available depending on the specific application and available budget. A diving rebreather is safety-critical life-support equipment – some modes of failure can kill the diver without warning, others can require immediate appropriate response for survival.

Surface supplied diving gas reclaim systems edit

A helium reclaim system (or push-pull system) is used to recover helium based breathing gas after use by the diver when this is more economical than losing it to the environment in open circuit systems. The recovered gas is passed through a scrubber system to remove carbon dioxide, filtered to remove odours, and pressurised into storage containers, where it may be mixed with oxygen to the required composition for re-use, either immediately, or at a later date.

Saturation diving life-support systems edit

The life support system provides breathing gas and other services to support life for the personnel under pressure in the accommodation chambers and closed diving bell. It includes the following components:[20]

  • Breathing gas supply, distribution and recycling equipment: scrubbers, filters, boosters, compressors, mixing, monitoring, and storage facilities
  • Chamber climate control system - control of temperature and humidity, and filtration of gas
  • Instrumentation, control, monitoring and communications equipment
  • Fire suppression systems
  • Sanitation systems

The life support system for the bell provides and monitors the main supply of breathing gas, and the control station monitors the deployment and communications with the divers. Primary gas supply, power and communications to the bell are through a bell umbilical, made up from a number of hoses and electrical cables twisted together and deployed as a unit.[21] This is extended to the divers through the diver umbilicals.[20]

The accommodation life support system maintains the chamber environment within the acceptable range for health and comfort of the occupants. Temperature, humidity, breathing gas quality, sanitation systems, and equipment function are monitored and controlled.[21]

Atmospheric diving suits edit

 
US Navy atmospheric diving suit

An atmospheric diving suit is a small one-man articulated submersible of roughly anthropomorphic form, with limb joints which allow articulation under external pressure while maintaining an internal pressure of one atmosphere. Breathing gas supply may be surface supplied by umbilical, or from a rebreather carried on the suit. An emergency gas supply rebreather may also be fitted to a suit with either surface supply or rebreather for primary breathing gas. As the internal pressure is maintained at one atmosphere, there is no risk of acute oxygen toxicity. This is an underwater diving application, but has more in common with industrial applications than with ambient pressure scuba rebreathers.

Industrial and rescue self-contained rebreathers edit

 
Mine rescue rebreathers in a Czech museum

Different design criteria apply to SCBA rebreathers for use only out of the water:

  • There is no variation in ambient pressure on the components. The counterlung may be placed for comfort and convenience.
  • Cooling of the gas in the breathing loop may be desirable, as the absorbent produces heat as it reacts with carbon dioxide, and the warming of the gas is not welcome in hot industrial situations such as firefighting and deep mines.[22]
  • Absorbent containers may in some cases rely on gravity for preventing channeling.
  • If a full-face mask is used, it may have viewports designed for convenience or improved field of vision, and they do not need to be flat and parallel to prevent visual distortion as when underwater.[22]
  • In firefighting rebreathers, consideration must be given to making the set reasonably flame-proof and protecting it from heat and debris impacts.[22]
  • The need to ditch the set quickly may not arise, and harness straps may not need a quick-release.
  • Buoyancy is not a consideration, but weight may be critical. Good ergonomic design for ease of carrying, comfort, and balance are important where the unit may be worn in confined spaces, while climbing and crawling through small gaps.[22]
  • A spring loaded counterlung pressurisation system may be used to provide slight positive pressure in the breathing loop, to prevent noxious gas entry if the mask seal is not perfect.[22]
  • There are no constraints due to the physiological effects of breathing under pressure. Complex gas mixtures are unnecessary. Oxygen rebreathers can usually be used, which makes the design considerably simpler, and the mechanism more reliable.
  • A system allowing the user to access drinking water from a bag may be fitted, A bite operated valve van be used to control flow.[22]
  • Radio voice communications may be fitted.[22]
  • A constant mass flow systen may be used to ensure a minimum fresh gas supply, with a demand valve to add gas if the loop is emptied.[22]
  • Gas supply and absorbent duratio would usually be matched for efficiency[22]
  • Insulation may be needed for the breathing loop for use in sub-zero temperatures where freezing of the absorbent would reduce its effectiveness.[22]
  • A water trap may be provided to collect condensed water from the absorbent reaction and from metabolic product.[22]
  • Monitoring functions may include:[22]
    • Cylinder pressure (analog and digital)
    • Estimated remaining duration of use until residual low pressure warning is activated
    • Temperature indication
    • Automatic recording of warning signals
  • Optical and/or acoustic warning signals may be provided for:[22]
    • Low gas pressure in the cylinder
    • Alarm triggered by lack of user movement
    • Manually triggered alarm.

Mountaineering rebreathers edit

Mountaineering rebreathers provide oxygen at a higher concentration than available from atmospheric air in a naturally hypoxic environment. They need to be lightweight and to be reliable in severe cold including not getting choked with deposited frost.[23] A high rate of system failures due to extreme cold has not been solved.[citation needed] Breathing pure oxygen results in an elevated partial pressure of oxygen in the blood: a climber breathing pure oxygen at the summit of Mount Everest has a greater oxygen partial pressure than breathing air at sea level. This results in being able to exert greater physical effort at altitude. The exothermic reaction helps keep the scrubber contents from freezing, and helps reduce heat loss from the user.

Both chemical and compressed gas oxygen have been used in experimental closed-circuit oxygen systems – the first on Mount Everest in 1938. The 1953 expedition used closed-circuit oxygen equipment developed by Tom Bourdillon and his father for the first assault team of Bourdillon and Evans; with one "dural" 800l compressed oxygen cylinder and soda lime canister (the second (successful) assault team of Hillary and Tenzing used open-circuit equipment).[24]

Rebreathers for unpressurised aircraft and high altitude parachuting edit

Similar requirement and working environment to mountaineering, but weight is less of a problem. The Soviet IDA71 rebreather was also manufactured in a high altitude version, which was operated as an oxygen rebreather.

Anaesthesia systems edit

Anaesthetic machines can be configured as rebreathers to provide oxygen and anaesthetic gases to a patient during surgery or other procedures that require sedation. An absorbent is present in the machine to remove the carbon dioxide from the loop.[25]

Both semi-closed and fully closed circuit systems may be used for anaesthetic machines, and both push-pull (pendulum) two directional flow and one directional loop systems are used.[26] The breathing circuit of a loop configured machine has two unidirectional valves so that only scrubbed gas flows to the patient while expired gas goes back to the machine.[25]

The anaesthetic machine can also provide gas to ventilated patients who cannot breathe on their own.[27] A waste gas scavenging system removes any gasses from the operating room to avoid environmental contamination.[28]

Space suits edit

 
Buzz Aldrin on the Moon on the 1969 Apollo 11 mission, showing the portable life support system.
 
Orlan space suit on an EVA from the International Space Station, with the life-support umbilical in view.

One of the functions of a space suit is to provide the wearer with breathing gas. This can be done via an umbilical from the life-support systems of the spacecraft or habitat, or from a primary life support system carried on the suit. Both of these systems involve rebreather technology as they both remove carbon dioxide from the breathing gas and add oxygen to compensate for oxygen used by the wearer. Space suits usually use oxygen rebreathers as this allows a lower pressure in the suit which gives the wearer better freedom of movement.

Habitat life-support systems edit

Submarines, underwater habitats, bomb shelters, space stations, and other living spaces occupied by several people over medium to long periods on a limited gas supply, are equivalent to closed circuit rebreathers in principle, but generally rely on mechanical circulation of breathing gas through the scrubbers.

Safety edit

There are several safety issues with rebreather equipment, and these tend to be more severe in diving rebreathers.

Hazards edit

Some of the hazards are due to the way the equipment works, while others are related to the environment in which the equipment is used, as rebreathers are usually used where no breathable ambient atmosphere is available.

Hypoxia edit

Hypoxia can occur in any rebreather which contains enough inert gas to allow breathing without triggering automatic gas addition.

In an oxygen rebreather this can occur if the loop is not sufficiently purged at the start of use. Purging is the replacement of the original gas content by fresh gas, and may have to be repeated to completely remove inert gas. Purging should be done while breathing off the unit so that the inert gas in the user's lungs and body tissues that finds its way into the loop is also removed from the system.

Carbon dioxide buildup edit

Carbon dioxide buildup will occur if the scrubber medium is absent, badly packed, inadequate or exhausted. The normal human body is fairly sensitive to carbon dioxide partial pressure, and a buildup will be noticed by the user. However, there is not often much that can be done to rectify the problem except changing to another breathing gas supply until the scrubber can be repacked. Continued use of a rebreather with an ineffective scrubber is not possible for very long, as the levels will become toxic and the user will experience extreme respiratory distress, followed by loss of consciousness and death. The rate at which these problems develop depends on the volume of the circuit and the metabolic rate of the user at the time.

Carbon dioxide buildup can also occur when a combination of exertion and work of breathing exceeds the capacity of the user. If this occurs where the user cannot reduce exertion sufficiently, it may be impossible to correct. This problem is more likely to occur with diving rebreathers at depths where the density of the breathing gas is severely elevated.[29][30][31]

Leakage of toxic gases into the breathing loop edit

Industrial rebreathers are often used where the ambient air is contaminated, and may be toxic. Parts of the loop will be at a slightly lower than external ambient pressure during inhalation, and if the circuit is not airtight external gases may leak in. This is a particular issue around the edge of a full-face mask, where the rubber mask skirt must seal against the user's face.

Fire hazards of high concentration of oxygen edit

High partial pressures of oxygen greatly increase fire hazard, and many materials which are self-extinguishing in atmospheric air will burn continuously in a high oxygen concentration. This is more of a hazard for terrestrial applications such as rescue and firefighting than for diving, where the ignition risk is relatively low.

Caustic cocktail edit

Caused by a loop flood reaching the absorbent canister, so only applicable in immersed applications.

Failure modes edit

Scrubber failure edit

The term "break-through" means the failure of the scrubber to continue removing sufficient carbon dioxide from the gas circulating in the loop. This will inevitably happen if the scrubber is used too long, but can happen prematurely in some circumstances. There are several ways that the scrubber may fail or become less efficient:

  • Complete consumption of the active ingredient in a "general break through". Depending on scrubber design and user workload, this may be gradual, allowing the user to become aware of the problem in time to make a controlled exit or bailout to open circuit, or relatively sudden, triggering an urgent or emergency response.
  • Bypassing the absorbent. The absorbent granules must be packed closely so that all exhaled gas comes into contact with the surface of soda lime and the canister is designed to avoid any large spaces or gaps between the absorbent granules or between the granules and the canister walls that would let gas bypass contact with the absorbent. If any of the seals, such as O-rings, or spacers that prevent bypassing of the scrubber, are not present or not fitted properly, or if the scrubber canister has been incorrectly packed or fitted, it may allow the exhaled gas to bypass the absorbent, and the scrubber will be less effective. This failure mode is also called "tunneling" when absorbent settles to form void spaces inside the canister. Bypass will cause an unexpected early break-through.
  • When the gas mix is under pressure at depth, the gas molecules are more densely packed, and the carbon dioxide molecules' mean path between collisions is shorter, so they are not so free to move around to reach the absorbent surface, and require a longer dwell time. Because of this effect, the scrubber must be bigger for deep diving than is needed for a shallow-water, industrial or high altitude rebreather.
  • Carbon dioxide absorbent can be caustic and can cause burns to the eyes, mucous membranes and skin. A mixture of water and absorbent occurs when the scrubber floods and depending on the chemicals used, can produce a chalky taste or a burning sensation if the contaminated water reaches the mouthpiece, which should prompt the diver to switch to an alternative source of breathing gas and rinse their mouth out with water. This is known to rebreather divers as a caustic cocktail. The excessive wetting of the absorbent also reduces the rate of carbon dioxide removal and can cause premature break-through even if no caustic liquid reaches the diver. Work of breathing may also increase. Many modern diving rebreather absorbents are designed not to produce this caustic fluid if they get wet.[clarification needed]
  • In below-freezing operation (primarily mountain climbing), wet scrubber chemicals can freeze when oxygen bottles are changed, while there is a pause in the exothermic reaction of taking up the carbon dioxide, thus preventing carbon dioxide from reaching the scrubber material, and slowing the reaction when used again.

Other failure modes edit

  • Flooding of the ambient pressure volume can occur in diving rebreathers.
  • Gas leakage to or from the ambient pressure volume can occur. Since the volume of gas lost or gained is likely to be very small, it is most relevant when the surroundings contain toxic gases or fumes.
  • Oxygen monitoring failure can lead to incorrect partial pressure of oxygen in the breathing gas. This is only relevant in mixed gas rebreathers used for diving.
  • Gas injection system failure is also mainly a problem of mixed gas diving rebreathers. Oxygen rebreathers gas injection systems are generally robust and reliable and can be manually overridden if they fail, and this form of failure is identifiable by an inappropriate volume of gas in the ambient pressure volume of the rebreather.

History edit

Early history edit

Around 1620, Cornelius Drebbel discovered that heating saltpetre (potassium nitrate) would generate oxygen.[32]

The first basic rebreather based on carbon dioxide absorption was patented in France in 1808 by Pierre-Marie Touboulic from Brest, a mechanic in Napoleon's Imperial Navy. This early rebreather design worked with an oxygen reservoir, the oxygen being delivered progressively by the diver and circulating in a closed circuit through a sponge soaked in limewater, a solution of calcium hydroxide in water.[33][34] Touboulic called his invention Ichtioandre (Greek for 'fish-man').[35][citation needed] There is no evidence of a prototype having been manufactured.

A prototype rebreather was built in 1849 by Pierre Aimable De Saint Simon Sicard,[36]

In 1853 Professor T. Schwann presented a rebreather at the Belgian Academy of Science.[37][34] It had a large back mounted oxygen tank with working pressure of about 13.3 bar, and two scrubbers containing sponges soaked in a caustic soda solution.[34]

Working rebreathers edit

 
Henry Fleuss, inventor of the rebreather

The first commercially practical closed-circuit scuba was designed and built by the diving engineer Henry Fleuss in 1878, while working for Siebe Gorman in London.[38][11] His self-contained breathing apparatus consisted of a rubber mask connected to a breathing bag, with (estimated) 50–60% O2 supplied from a copper tank and CO2 scrubbed by rope yarn soaked in a solution of caustic potash; the system giving a duration of about three hours.[11][39] Fleuss tested his device in 1879 by spending an hour submerged in a water tank, then one week later by diving to a depth of 5.5 m in open water, upon which occasion he was slightly injured when his assistants abruptly pulled him to the surface.

His apparatus was first used under operational conditions in 1880 by Alexander Lambert, the lead diver on the Severn Tunnel construction project, who was able to travel 1000 feet in the darkness to close several submerged sluice doors in the tunnel; this had defeated his best efforts with standard diving dress due to the danger of the air supply hose becoming fouled on submerged debris, and the strong water currents in the workings.[11] In 1880 Fleuss, used a rebreather to inspect Seaham Colliery in the UK after a gas explosion.[34]

Fleuss and Siebe Gorban developed the Proto breathing apparatus for mine rescue in 1911.[34]

Fleuss continually improved his apparatus, adding a demand regulator and tanks capable of holding greater amounts of oxygen at higher pressure. Sir Robert Davis, head of Siebe Gorman, improved the oxygen rebreather in 1910[11][39] with his invention of the Davis Submerged Escape Apparatus, the first practical rebreather to be made in quantity. While intended primarily as an emergency escape apparatus for submarine crews, it was soon also used for diving, being a handy shallow water diving apparatus with a thirty-minute endurance,[39] and as an industrial breathing set.

 
Davis Submerged Escape Apparatus being tested at the submarine escape test tank at HMS Dolphin, Gosport, 14 December 1942

The rig comprised a rubber breathing/buoyancy bag containing a canister of barium hydroxide to scrub exhaled CO2 and, in a pocket at the lower end of the bag, a steel pressure cylinder holding approximately 56 litres of oxygen at a pressure of 120 bar. The cylinder was equipped with a control valve and was connected to the breathing bag. Opening the cylinder's valve admitted oxygen to the bag and charged it to the pressure of the surrounding water. The rig also included an emergency buoyancy bag on the front of to help keep the wearer afloat. The DSEA was adopted by the Royal Navy after further development by Davis in 1927.[40] Various industrial oxygen rebreathers such as the Siebe Gorman Salvus and the Siebe Gorman Proto, both invented in the early 1900s, were derived from it.

Professor Georges Jaubert invented the chemical compound Oxylithe in 1907. It was a form of sodium peroxide (Na2O2) or sodium superoxide (NaO2). As it absorbs carbon dioxide in a rebreather's scrubber it emits oxygen. This compound was first incorporated into a rebreather design by Captain S.S. Hall and Dr. O. Rees of the Royal Navy in 1909. Although intended for use as a submarine escape apparatus, it was never accepted by the Royal Navy and was instead used for shallow water diving.[39]

In 1912 the German firm Dräger began mass production of their own version of standard diving dress with the air supply from a rebreather. The apparatus had been invented some years earlier by Hermann Stelzner, an engineer at the Dräger company,[41] for mine rescue.[42]

In the 1930s, after some tragic accidents in the 1920s, the United States Navy began to equip Porpoise- and Salmon-class submarines with primitiv rebreathers called Momsen lungs, which where in use until the 1960s.

Rebreathers during World War II edit

 
A 1945 Royal Navy frogman with Davis apparatus

In the 1930s, Italian sport spearfishers began to use the Davis rebreather; Italian manufacturers received a licence from the English patent holders to produce it. This practice soon came to the attention of the Italian Navy, which developed an extensively upgraded model designed by Teseo Tesei and Angelo Belloni [it] that was used by its frogman unit Decima Flottiglia MAS with good results during World War II.[39]

During the Second World War, captured Italian frogmen's rebreathers influenced improved designs for British rebreathers.[39] Many British frogmen's breathing sets used aircrew breathing oxygen cylinders salvaged from shot-down German Luftwaffe aircraft. The earliest of these breathing sets may have been modified Davis Submerged Escape Apparatus; their fullface masks were the type intended for the Siebe Gorman Salvus, but in later operations different designs were used, leading to a fullface mask with one big face window, at first circular or oval and later rectangular (mostly flat, but the sides curved back to allow better vision sideways). Early British frogman's rebreathers had rectangular counterlungs on the chest like Italian frogman's rebreathers, but later designs had a square recess in the top of the counterlung so it could extend further up toward the shoulders. In front they had a rubber collar that was clamped around the absorbent canister.[39] Some British armed forces divers used bulky thick diving suits called Sladen suits; one version of it had a flip-up single faceplate for both eyes to let the user get binoculars to his eyes when on the surface.

The Dräger rebreathers, especially the DM20 and DM40 model series, were used by the German helmet divers and German frogmen during World War II. Rebreathers for the US Navy were developed by Dr. Christian J. Lambertsen for underwater warfare.[43][44] Lambertsen held the first closed-circuit oxygen rebreather course in the United States for the Office of Strategic Services maritime unit at the Naval Academy on 17 May 1943.[44][45]

During and after WWII, needs arose in the armed forces to dive deeper than allowed by pure oxygen. That prompted, at least in Britain, design of simple constant-flow "mixture rebreather" variants of some of their diving oxygen rebreathers (= what is now called "nitrox"): SCMBA from the SCBA (Swimmer Canoeist's Breathing Apparatus), and CDMBA from the Siebe Gorman CDBA, by adding an extra gas supply cylinder. Before a dive with such a set, the diver had to know the maximum or working depth of his dive, and how fast his body used his oxygen supply, and from those to calculate what to set his rebreather's gas flow rate to.

Post-WWII edit

The diving pioneer Hans Hass used Dräger oxygen rebreathers in the early 1940s for underwater cinematography.

Due to the military importance of the rebreather, amply demonstrated during the naval campaigns of the Second World War, most governments were reluctant to issue the technology into the public domain. In Britain rebreather use for civilians was negligible, and the BSAC formally prohibited rebreather use by its members. The Italian firms Pirelli and Cressi-Sub at first each sold a model of sport diving rebreather, but after a while discontinued those models. Some home made rebreathers were used by cave divers to penetrate cave sumps.

Most high-altitude mountaineers use open-circuit oxygen equipment; the 1953 Everest expedition used both closed-circuit and open-circuit oxygen equipment: see bottled oxygen.

Eventually the Cold War ended, and in 1989 the Communist Bloc collapsed, and as a result the perceived risk of sabotage attacks by combat divers dwindled, and Western armed forces had less reason to requisition civilian rebreather patents, and automatic and semi-automatic recreational diving rebreathers with oxygen partial pressure sensors started to appear.

Manufacturers and models edit

Industrial/rescue:

  • Blackett's Aerophor – A nitrox semi-closed-circuit rebreather with liquid gas storage made in England from 1910 onwards for use in mine rescue and other industrial uses.[citation needed]
  • Sabre Safety
    • SEFA (Selected Elevated Flow Apparatus) – an industrial oxygen rebreather formerly made by Sabre Safety with 2 hours duration on a filling.[citation needed]
  • Siebe Gorman – British manufacturer of diving equipment and salvage contractor
    • The Savox was an oxygen rebreather with a use duration of 45 minutes. It had no hard casing and was worn in front of the body.[15]
    • Siebe Gorman Salvus – Industrial rescue and shallow water oxygen rebreather
  • IDA71 – Russian military rebreather for underwater and high altitude use

Others:


See also edit

  • Carbon dioxide scrubber – Device which absorbs carbon dioxide from circulated gas
  • Escape set – Self contained breathing apparatus providing gas to escape from a hazardous environment
  • Primary life support system, also known as Portable Life Support System – Life support device for a space suit
  • Self-contained breathing apparatus (SCBA) – Breathing gas supply system carried by the user (surface-only (industrial) breathing sets including rebreathers)

References edit

  1. ^ a b NOAA Diving Program (U.S.) (28 Feb 2001). Joiner, James T. (ed.). NOAA Diving Manual, Diving for Science and Technology (4th ed.). Silver Spring, Maryland: National Oceanic and Atmospheric Administration, Office of Oceanic and Atmospheric Research, National Undersea Research Program. ISBN 978-0-941332-70-5. CD-ROM prepared and distributed by the National Technical Information Service (NTIS)in partnership with NOAA and Best Publishing Company
  2. ^ Dhami, P.S.; Chopra, G.; Shrivastava, H.N. (2015). A Textbook of Biology. Jalandhar, Punjab: Pradeep Publications. pp. V/101.
  3. ^ US Navy (1 December 2016). U.S. Navy Diving Manual Revision 7 SS521-AG-PRO-010 0910-LP-115-1921 (PDF). Washington, DC.: US Naval Sea Systems Command. Chapter 15 - Electronically Controlled Closed-Circuit Underwater Breathing Apparatus (EC-UBA) Diving, Section 15-2 Principles of operation
  4. ^ a b US Navy Diving Manual 2016, Chapter 15 - Electronically Controlled Closed-Circuit Underwater Breathing Apparatus (EC-UBA) Diving, Section 15-2 Principles of operation.
  5. ^ James W. Miller, ed. (1979). "Fig 2.4". NOAA Diving Manual (2nd ed.). Washington, DC.: US Dept of Commerce - National Oceanographic and Atmospheric Administration. pp. 2–7.
  6. ^ a b c d e Odom, J. (August 1999). An Introduction to Semi-Closed Circuit Rebreathers: The Dräger Series of Recreational Rebreathers (PDF) (Revision 4a ed.). Technical Diving International, 1995.
  7. ^ Gant, Nicholas; van Waart, Hanna; Ashworth, Edward T.; Mesley, Peter; Mitchell, Simon J. (December 2019). "Performance of cartridge and granular carbon dioxide absorbents in a closed-circuit diving rebreather". Diving and Hyperbaric Medicine. 49 (4): 298–303. doi:10.28920/dhm49.4.298-303. PMC 7039778. PMID 31828749.
  8. ^ a b c d Sandham, John, ed. (2009). "EBME & Clinical Engineering Articles: Soda lime production". www.ebme.co.uk. Retrieved 24 October 2022.
  9. ^ Greenwood, Norman N.; Earnshaw, Alan (1984). Chemistry of the Elements. Oxford: Pergamon Press. ISBN 978-0-08-022057-4.
  10. ^ Older, P. (1969). . Royal Australian Navy, School of Underwater Medicine. RANSUM-4-69. Archived from the original on May 9, 2008. Retrieved 2008-06-14.{{cite journal}}: CS1 maint: unfit URL (link)
  11. ^ a b c d e Davis, RH (1955). Deep Diving and Submarine Operations (6th ed.). Tolworth, Surbiton, Surrey: Siebe Gorman & Company Ltd. p. 693.
  12. ^ US Navy (2006). "Chapter 19: Closed-Circuit Oxygen UBA Diving". US Navy Diving Manual, 6th revision. United States: US Naval Sea Systems Command. pp. 19–9. Retrieved 2008-06-15.
  13. ^ Kelley, JS; Herron, JM; Dean, WW; Sundstrom, EB (1968). . US Navy Experimental Diving Unit Technical Report. NEDU-Evaluation-11-68. Archived from the original on May 9, 2008. Retrieved 2009-01-31.{{cite journal}}: CS1 maint: unfit URL (link)
  14. ^ Holquist, Jordan B.; Klaus, David M.; Graf, John C. (13–17 July 2014). Characterization of Potassium Superoxide and a Novel Packed Bed Configuration for Closed Environment Air Revitalization (PDF). 44th International Conference on Environmental Systems ICES-2014-192. Tucson, Arizona.
  15. ^ a b Robinson, Brian. Taylor, Fionn (ed.). "Breathing Apparatus". Bob's History of Mining. Retrieved 27 December 2013.
  16. ^ Richardson, Drew; Menduno, Michael; Shreeves, Karl (1996). . Diving Science and Technology Workshop.: 286. Archived from the original on September 15, 2008. Retrieved 2008-08-20.{{cite journal}}: CS1 maint: unfit URL (link)
  17. ^ "DESCO 29019 U.S. Navy Helium Diving Helmet w/Double Exhaust Valve". DESCO. Retrieved 2 July 2019.
  18. ^ "Going deep". divingheritage.com. Retrieved 2 July 2019.
  19. ^ "The OBS A/S reclaim helmet". DiveScrap Index - the scrapbook of diving history. Retrieved 2 July 2019.
  20. ^ a b Crawford, J. (2016). "8.5.1 Helium recovery systems". Offshore Installation Practice (revised ed.). Butterworth-Heinemann. pp. 150–155. ISBN 9781483163192.
  21. ^ a b Staff, US Navy (2006). "15". US Navy Diving Manual, 6th revision. United States: US Naval Sea Systems Command. Retrieved 15 June 2008.
  22. ^ a b c d e f g h i j k l m "Dräger PSS BG 4 plus Breathing Apparatus" (PDF). www.draeger.com. Retrieved 30 October 2022.
  23. ^ Hendricks, David M; Pollock, Neal W; Natoli, Michael J; Hobbs, Gene W; Gabrielova, Ivana; Vann, Richard D (1999). "Mountaineering oxygen mask efficiency at 4572 m.". In: Roach RC, Wagner PD, Hackett PH. Hypoxia: Into the Next Millennium (Advances in Experimental Medicine and Biology Series). Kluwer Academic: New York: 387–388.
  24. ^ Hunt, John (1953). The Ascent of Everest. London: Hodder & Stoughton. pp. 257–262.
  25. ^ a b staff (2003-08-18). "Breathing Circuit". University of Florida. Retrieved 2013-04-25.
  26. ^ Ravishankar, M. . www.capnography.com. Archived from the original on 17 May 2013. Retrieved 30 April 2013.
  27. ^ staff (2003-08-18). "Mechanical and Manual Ventilation Systems". University of Florida. Retrieved 2013-04-25.
  28. ^ staff (2003-08-18). "The Scavenging System". University of Florida. Retrieved 2013-04-25.
  29. ^ Mitchell, Simon J.; Cronjé, Frans J.; Meintjes, W.A. Jack; Britz, Hermie C. (2007). "Fatal Respiratory Failure During a "Technical" Rebreather Dive at Extreme Pressure". Aviation, Space, and Environmental Medicine. 78 (2): 81–86. PMID 17310877. Retrieved 21 November 2019.
  30. ^ Mitchell, Simon (August 2008). "Four: Carbon Dioxide Retention". In Mount, Tom; Dituri, Joseph (eds.). Exploration and Mixed Gas Diving Encyclopedia (1st ed.). Miami Shores, Florida: International Association of Nitrox Divers. pp. 279–286. ISBN 978-0-915539-10-9.
  31. ^ Mitchell, Simon (2015). "Respiratory failure in technical diving". www.youtube.com. DAN Southern Africa. Retrieved 6 October 2021.
  32. ^ "Cornelius Drebbel: inventor of the submarine". Dutch Submarines. Archived from the original on 2012-05-30. Retrieved 2008-02-23.
  33. ^ Bahuet, Eric (19 October 2003). "Avec ou sans bulles? (With or without bubbles)". La Plongée Souterrain (in French). plongeesout.com. Introduction. Retrieved 5 February 2017.
  34. ^ a b c d e "Breathing apparatus in mining: Don't hold your breath". Australian Mine Safety Journal. 19 October 2020. Retrieved 31 October 2022.
  35. ^ Bahuet, Eric. "L'Ichtioandre (illistration)". La Plongée Souterrain (in French). plongeesout.com. Retrieved 5 February 2017.
  36. ^ Saint Simon Sicard's invention as mentioned by the Musée du Scaphandre website (a diving museum in Espalion, south of France)
  37. ^ Bech, Janwillem. "Theodor Schwann". Retrieved 2008-02-23.
  38. ^ . scubahalloffame.com. Archived from the original on 2015-01-12.
  39. ^ a b c d e f g Quick, D. (1970). . Royal Australian Navy, School of Underwater Medicine. RANSUM-1-70. Archived from the original on May 9, 2008. Retrieved 2009-03-03.{{cite journal}}: CS1 maint: unfit URL (link)
  40. ^ Paul Kemp (1990). The T-Class submarine – The Classic British Design. Arms and Armour. p. 105. ISBN 0-85368-958-X.
  41. ^ "Dräger diving helmets". Drägerwerk. www.divingheritage.com. Retrieved 12 December 2016.
  42. ^ Bech, Janwillem (ed.). "Photos Draeger 1907 Rescue Apparatus". Retrieved 19 December 2017.
  43. ^ Vann RD (2004). . Undersea Hyperb Med. 31 (1): 21–31. PMID 15233157. Archived from the original on June 13, 2008. Retrieved 2008-04-25.{{cite journal}}: CS1 maint: unfit URL (link)
  44. ^ a b Butler, F.K. (2004). . Undersea Hyperb Med. 31 (1): 3–20. PMID 15233156. Archived from the original on June 13, 2008. Retrieved 2008-04-25.{{cite journal}}: CS1 maint: unfit URL (link)
  45. ^ Hawkins T (Jan–Mar 2000). "OSS Maritime". The Blast. 32 (1).

External links edit

  •   Media related to Rebreathers at Wikimedia Commons
  • NIOSH Docket # 123, titled "Reevaluation of NIOSH limitations on and precaution for safe use of positive-pressure closed-circuit SCBA" is available at

rebreather, rebreathers, used, underwater, diving, diving, rebreather, diving, with, rebreather, diving, breathing, recycling, habitat, life, support, system, surface, recycling, breathing, recovered, from, diver, reclaim, system, rebreather, breathing, appara. For rebreathers used in underwater diving see Diving rebreather For diving with a rebreather see Rebreather diving For breathing gas recycling in a habitat see Life support system For surface recycling of breathing gas recovered from a diver see Gas reclaim system A rebreather is a breathing apparatus that absorbs the carbon dioxide of a user s exhaled breath to permit the rebreathing recycling of the substantially unused oxygen content and unused inert content when present of each breath Oxygen is added to replenish the amount metabolised by the user This differs from open circuit breathing apparatus where the exhaled gas is discharged directly into the environment The purpose is to extend the breathing endurance of a limited gas supply and for covert military use by frogmen or observation of underwater life eliminating the bubbles produced by an open circuit system and in turn not scaring wildlife being filmed A rebreather is generally understood to be a portable unit carried by the user The same technology on a vehicle or non mobile installation is more likely to be referred to as a life support system RebreatherA fully closed circuit electronic rebreather AP Diving Inspiration AcronymCCUBA closed circuit underwater breathing apparatus CCR closed circuit rebreather SCR semi closed rebreather UsesBreathing setRelated itemsDavis apparatus Self contained breathing apparatus Escape hoodRebreather technology may be used where breathing gas supply is limited such as underwater in space where the environment is toxic or hypoxic as in firefighting mine rescue high altitude operations or where the breathing gas is specially enriched or contains expensive components such as helium diluent or anaesthetic gases Rebreathers are used in many environments Underwater diving rebreathers are a type of self contained underwater breathing apparatus which have provisions for both a primary and emergency gas supply On land they are used in industrial applications where poisonous gases may be present or oxygen may be absent firefighting where firefighters may be required to operate in an atmosphere immediately dangerous to life and health for extended periods in hospital anaesthesia breathing systems to supply controlled concentrations of anaesthetic gases to patients without contaminating the air that the staff breathe and at high altitude where the partial pressure of oxygen is low for high altitude mountaineering In aerospace there are applications in unpressurised aircraft and for high altitude parachute drops and above the Earth s atmosphere in space suits for extra vehicular activity Similar technology is used in life support systems in submarines submersibles atmospheric diving suits underwater and surface saturation habitats spacecraft and space stations and in gas reclaim systems used to recover the large volumes of helium used in saturation diving The recycling of breathing gas comes at the cost of technological complexity and specific hazards some of which depend on the application and type of rebreather used Mass and bulk may be greater or less than open circuit depending on circumstances Electronically controlled diving rebreathers may automatically maintain a partial pressure of oxygen between programmable upper and lower limits or set points and be integrated with decompression computers to monitor the decompression status of the diver and record the dive profile Contents 1 General concept 2 Architecture 2 1 Pendulum 2 2 Loop 3 Components 3 1 Counterlung 3 2 Scrubber 3 3 Breathing hoses 3 4 Mouthpiece or facemask 3 5 Oxygen supply 3 6 Valves 3 7 Oxygen sensors 4 System variants 4 1 Oxygen rebreathers 4 1 1 Oxygen feed options 4 2 Mixed gas rebreathers 4 3 Rebreathers using an absorbent that releases oxygen 4 4 Rebreathers which use liquid oxygen 4 4 1 Cryogenic rebreather 5 Fields of application 5 1 Diving rebreathers 5 1 1 Surface supplied diving gas reclaim systems 5 1 2 Saturation diving life support systems 5 2 Atmospheric diving suits 5 3 Industrial and rescue self contained rebreathers 5 4 Mountaineering rebreathers 5 5 Rebreathers for unpressurised aircraft and high altitude parachuting 5 6 Anaesthesia systems 5 7 Space suits 5 8 Habitat life support systems 6 Safety 6 1 Hazards 6 1 1 Hypoxia 6 1 2 Carbon dioxide buildup 6 1 3 Leakage of toxic gases into the breathing loop 6 1 4 Fire hazards of high concentration of oxygen 6 1 5 Caustic cocktail 6 2 Failure modes 6 2 1 Scrubber failure 6 2 2 Other failure modes 7 History 7 1 Early history 7 2 Working rebreathers 7 3 Rebreathers during World War II 7 4 Post WWII 8 Manufacturers and models 9 See also 10 References 11 External linksGeneral concept editAs a person breathes the body consumes oxygen and produces carbon dioxide Base metabolism requires about 0 25 L min of oxygen from a breathing rate of about 6 L min and a fit person working hard may ventilate at a rate of 95 L min but will only metabolise about 4 L min of oxygen 1 The oxygen metabolised is generally about 4 to 5 of the inspired volume at normal atmospheric pressure or about 20 of the available oxygen in the air at sea level Exhaled air at sea level contains roughly 13 5 to 16 oxygen 2 The situation is even more wasteful of oxygen when the oxygen fraction of the breathing gas is higher and in underwater diving the compression of breathing gas due to depth makes the recirculation of exhaled gas even more desirable as an even larger proportion of open circuit gas is wasted Continued rebreathing of the same gas will deplete the oxygen to a level which will no longer support consciousness and eventually life so gas containing oxygen must be added to the breathing gas to maintain the required concentration of oxygen 3 However if this is done without removing the carbon dioxide it will rapidly build up in the recycled gas resulting almost immediately in mild respiratory distress and rapidly developing into further stages of hypercapnia or carbon dioxide toxicity A high ventilation rate is usually necessary to eliminate the metabolic product carbon dioxide CO2 The breathing reflex is triggered by CO2 concentration in the blood not by the oxygen concentration so even a small buildup of CO2 in the inhaled gas quickly becomes intolerable if a person tries to directly rebreathe their exhaled breathing gas they will soon feel an acute sense of suffocation so rebreathers must remove the CO2 in a component known as a carbon dioxide scrubber 4 By adding sufficient oxygen to compensate for the metabolic usage removing the carbon dioxide and rebreathing the gas most of the volume is conserved 4 nbsp Relation of physiological effects to carbon dioxide concentration and exposure period 5 Effects of different levels of oxygen partial pressure 1 PO2 bar Application and effect lt 0 08 Coma ultimately leading to death0 08 0 10 Unconsciousness in most people0 09 0 10 Serious signs symptoms of hypoxia0 14 0 16 Initial signs symptoms of hypoxia normal environment oxygen in some very high altitude areas 0 21 Normal environment oxygen sea level air 0 35 0 40 Normal saturation dive PO2 level0 50 Threshold for whole body effects maximum saturation dive exposure1 0 1 20 Common range for recreational closed circuit set point1 40 Recommended limit for recreational open circuit bottom sector1 60 NOAA limit for maximum exposure for a working diverRecreational technical limit for decompression2 20 Commercial military Sur D chamber surface decompression on 100 O2 at 12 msw meters of sea water 2 40 40 O2 nitrox recompression treatment gas for use in the chamber at 50 msw2 80 100 O2 recompression treatment gas for use in the chamber at 18 msw3 00 50 O2 nitrox recompression treatment gas for use in the chamber at 50 mswArchitecture edit nbsp Comparison of pendulum and loop rebreather architecture1 Mouthpiece with dive surface valve2 Two way breathing hose2a Exhalation hose with non return valve2b Inhalation hose with non return valve3 Scrubber4 Counterlung5 Automatic make up valve6 Manual bypass valve7 Breathing gas storage cylinder8 Cylinder valve9 Regulator first stage10 Cylinder pressure gauge11 Over pressure valveThere are two basic arrangements controlling the flow of breathing gas inside the rebreather known as the pendulum and loop systems Pendulum edit In the pendulum configuration the user inhales gas from the counterlung through a breathing hose and exhaled gas returns to the counter lung by flowing back through the same hose The scrubber is usually between the breathing hose and the counterlung bag and gas flow is bi directional All of the flow passages between the user and the active absorbent in the scrubber are dead space volume containing gas which is rebreathed without modification by the rebreather The dead space increases as the absorbent is depleted Breathing hose volume must be minimised to limit dead space Loop edit In the loop configuration the user inhales gas through one hose and exhales through a second hose Exhaled gas flows into the scrubber from one side and exits at the other side There may be one large counterlung on either side of the scrubber or two smaller counterlungs one on each side of the scrubber Flow is in one direction enforced by non return valves which are usually in the breathing hoses where they join the mouthpiece Only the flow passage in the mouthpiece before the split between inhalation and exhalation hoses is dead space and this is not affected by hose volume 6 Components edit nbsp Oxygen rebreather KIP 8 interior showing the basic components nbsp Russian firefighting rebreather KIP 8 exteriorThere are some components that are common to almost all personal portable rebreathers These include the ambient pressure breathing volume components usually called the breathing loop in a circulating flow rebreather and the make up gas supply and control system Counterlung edit The counterlung is an airtight bag of strong flexible material that holds the volume of the exhaled gas until it is inhaled again There may be a single counterlung or one on each side of the scrubber which allows a more even flow rate of gas through the scrubber which can reduce work of breathing and improve scrubber efficiency by a more consistent dwell time Scrubber edit Main article Carbon dioxide scrubber The scrubber is a container that has an inlet on one side and an outlet on the other side filled with carbon dioxide absorbent material mostly strong bases through which the exhaled gas passes to remove the carbon dioxide The absorbent may be granular or in the form of a moulded cartridge 7 Granular sorb may be manufactured by breaking up lumps of lime and sorting the granules by size or by moulding granules at a consistent size and shape 8 Gas flow through the scrubber may be in one direction in a loop rebreather or both ways in a pendulum rebreather A typical absorbent is Sodalime which is made up of calcium hydroxide Ca OH 2 and potassium hydroxide KOH or sodium hydroxide NaOH Either or both of these may be present The main component of soda lime is calcium hydroxide which is relatively cheap and easily available Other components may be present in the absorbent Sodium hydroxide is added to accelerate the reaction with carbon dioxide Other chemicals may be added to prevent unwanted decomposition products when used with standard halogenated inhalation anaesthetics An indicator may be included to show when carbon dioxide has dissolved in the water of the soda lime and formed carbonic acid changing the pH from basic to acid as the change of colour shows that the absorbent has reached saturation with carbon dioxide and must be changed 8 The carbon dioxide combines with water or water vapor to produce a weak carbonic acid CO2 H2O gt H2CO3 This reacts with the hydroxides to produce carbonates and water in an exothermic reaction 6 In the intermediate reaction the carbonic acid reacts exothermically with sodium hydroxide to form sodium carbonate and water H2CO3 2NaOH gt Na2CO3 2H2O heat In the final reaction the sodium carbonate reacts with the slaked lime calcium hydroxide to form calcium carbonate and sodium hydroxide Na2CO3 Ca OH 2 gt CaCO3 2NaOH The sodium hydroxide is then available again to react with more carbonic acid 8 100 grams 3 5 oz of this absorbent can remove about 15 to 25 litres 0 53 to 0 88 cu ft of carbon dioxide at standard atmospheric pressure 6 8 This process also heats and humidifies the air which is desirable for diving in cold water or climbing at high altitudes but not for working in hot environments Other reactions may be used in special circumstances Lithium hydroxide and particularly lithium peroxide may be used where low mass is important such as in space stations and space suits Lithium peroxide also replenishes the oxygen during the scrubbing reaction 9 Another method of carbon dioxide removal occasionally used in portable rebreathers is to freeze it out which is possible in a cryogenic rebreather which uses liquid oxygen The liquid oxygen absorbs heat from the carbon dioxide in a heat exchanger to convert the oxygen to gas which is sufficient to freeze the carbon dioxide This process also chills the gas which is sometimes but not always desirable Breathing hoses edit nbsp Draeger Ray dive surface valve with bite grip scuba mouthpiece non return valves and breathing hosesA breathing hose or sometimes breathing tube on a rebreather is a flexible tube for breathing gas to pass through at ambient pressure They are distinguished from the low intermediate and high pressure hoses which may also be parts of rebreather apparatus They have a wide enough bore to minimise flow resistance at the ambient pressure in the operational range for the equipment are usually circular in cross section and may be corrugated to let the user s head move about without the tube collapsing at kinks 6 Each end has an airtight connection to the adjacent component and they may contain a one way valve to keep the gas circulating the right way in a loop system Depending on the service they may be made of a flexible polymer an elastomer a fibre or cloth reinforced elastomer or elastomer covered with a woven fabric for reinforcement or abrasion resistance If the woven layer is bonded to the outside surface it protects the rubber from damage from scrapes but makes it more difficult to wash off contaminants 6 Breathing hoses are usually long enough to connect the apparatus to the user s head in all attitudes of their head but should not be unnecessarily long which will cause additional weight hydrodynamic drag risk snagging on things or contain excess dead space in a pendulum rebreather Breathing hoses can be tethered down to a diver s shoulders or ballasted for neutral buoyancy to minimise loads on the mouthpiece Mouthpiece or facemask edit A mouthpiece with bite grip an oro nasal mask a full face mask or a sealed helmet is provided so that the user can breathe from the unit hands free Oxygen supply edit A store of oxygen usually in a high pressure cylinder but sometimes as liquid oxygen that feeds gaseous oxygen into the ambient pressure breathing volume either continuously or when the user operates the oxygen addition valve or via a demand valve in an oxygen rebreather when the volume of gas in the breathing circuit becomes low and the pressure drops or in an electronically controlled mixed gas rebreather after a sensor has detected insufficient oxygen partial pressure and activates a solenoid valve Valves edit Valves are needed to control gas flow in the breathing volume and gas feed from the storage container They include Non return valves in the breathing loop of loop rebreathers which enforce one directional flow to minimise dead space Dive surface valves on diving rebreathers which prevent water from entering the breathing volume when the mouthpiece is removed or the user elects to breathe ambient air at the surface Gas supply valves including a cylinder valve to allow high pressure gas to flow from the cylinder This may be manually operated by the user to directly supply make up gas or may provide the gas to a pressure regulator which reduces the pressure to a few bar above ambient pressure and supplies this intermediate pressure gas to the gas feed system which may contain one or more of Manually operated feed valve Constant mass flow orifice or needle valve to provide a continuous feed Demand valve which automatically adds gas when the volume of the counterlung s is too low and pressure in the breathing volume drops below ambient pressure Overpressure valve to release excess gas This is mainly used in diving rebreathers to compensate for expansion during ascent Excess gas may also be vented past the skirt seal of a full face mask or through the nose when a mouthpiece is used Oxygen sensors edit See also Electro galvanic oxygen sensor Oxygen sensors may be used to monitor partial pressure of oxygen in mixed gas rebreathers to ensure that it does not fall outside the safe limits but are generally not used on oxygen rebreathers as the oxygen content is fixed at 100 and its partial pressure varies only with the ambient pressure System variants editRebreathers can be primarily categorised as diving rebreathers intended for hyperbaric use and other rebreathers used at pressures from slightly more than normal atmospheric pressure at sea level to significantly lower ambient pressure at high altitudes and in space Diving rebreathers must often deal with the complications of avoiding hyperbaric oxygen toxicity while normobaric and hypobaric applications can use the relatively trivially simple oxygen rebreather technology where there is no requirement to monitor oxygen partial pressure during use providing the ambient pressure is sufficient Oxygen rebreathers edit nbsp Siebe Gorman Proto 1 mine rescue rebreather a simple oxygen rebreather Further information Diving rebreather Oxygen rebreathers 2 This is the earliest type of rebreather and was commonly used by navies for submarine escape and shallow water diving work for mine rescue high altitude mountaineering and flight and in industrial applications from the early twentieth century Oxygen rebreathers can be remarkably simple and mechanically reliable and they were invented before open circuit scuba They only supply oxygen so there is no requirement to control the gas composition other than removing the carbon dioxide 10 Oxygen feed options edit Further information Diving rebreather Oxygen feed options In some rebreathers the oxygen cylinder has oxygen supply mechanisms in parallel One is constant flow the other is a manual on off valve called a bypass valve both feed into the same hose which feeds the counterlung 11 Others are supplied via a demand valve on the counterlung This will add gas at any time that the counterlung is emptied and the diver continues to inhale Oxygen can also be added manually by a button which activates the demand valve 12 Some simple oxygen rebreathers had no automatic supply system but only the manual feed valve and the diver had to operate the valve at intervals to refill the breathing bag as the volume of oxygen decreased below a comfortable level Mixed gas rebreathers edit Further information Diving rebreather Mixed gas rebreathers nbsp Mixed gas electronically controlled closed circuit diving rebreatherAll rebreathers other than oxygen rebreathers may be considered mixed gas rebreathers as the breathing gas is a mixture of oxygen and metabolically inactive diluent gas These can be divided into semi closed circuit where the supply gas is a breathable mixture containing oxygen and inert diluents usually nitrogen and helium and which is replenished by adding more of the mixture as the oxygen is used up sufficient to maintain a breathable partial pressure of oxygen in the loop and closed circuit rebreathers where two parallel gas supplies are used the diluent to provide the bulk of the gas and which is recycled and oxygen which is metabolically expended Carbon dioxide is considered a waste product and in a correctly functioning rebreather is effectively removed when the gas passes through the scrubber Rebreathers using an absorbent that releases oxygen edit nbsp Russian multipurpose rebreather IDA 71 with lid of casing opened showing interior one of the scrubber canisters can optionally be filled with superoxide Further information Diving rebreather Rebreathers using an absorbent that releases oxygen There have been a few rebreather designs e g the Oxylite which use potassium superoxide which gives off oxygen as it absorbs carbon dioxide as the carbon dioxide absorbent 4KO2 2CO2 2K2CO3 3O2 A small volume oxygen cylinder is needed to fill and purge the loop at the start of use 13 This technology may be applied to both oxygen and mixed gas rebreathers and can be used for diving and other applications Potassium superoxide reacts vigorously with liquid water releasing considerable heat and oxygen and causing a fire hazard so the more successful applications have been for space suits fire fighting and mine rescue 14 Rebreathers which use liquid oxygen edit Further information Diving rebreather Rebreathers which use liquid oxygen nbsp Aerorlox liquid oxygen rebreather in a coal mining museumA liquid oxygen supply can be used for oxygen or mixed gas rebreathers If used underwater the liquid oxygen container must be well insulated against heat transfer from the water Industrial sets of this type may not be suitable for diving and diving sets of this type may not be suitable for use out of water due to conflicting heat transfer requirements The set s liquid oxygen tank must be filled immediately before use Examples of the type include Blackett s Aerophor Aerorlox 15 Cryogenic rebreather edit Further information Diving rebreather Cryogenic rebreather A cryogenic rebreather removes the carbon dioxide by freezing it out in a snow box by the low temperature produced as liquid oxygen evaporates to replace the oxygen used Fields of application editUnderwater as a self contained breathing apparatus where it is sometimes known as closed circuit scuba as opposed to open circuit scuba where the diver exhales breathing gas into the surrounding water 16 Surface supplied diving equipment may incorporate rebreather technology either as a gas reclaim system where the surface supplied breathing gas is returned and scrubbed at the surface or as a gas extender carried by the diver 17 18 Rebreathers may also be used as self contained diver bailout systems for either scuba or surface supplied diving 19 Mine rescue and other industrial applications where poisonous gases may be present or oxygen may be absent Fire fighting where personnel may be required to operate in an atmosphere immediately dangerous to life and health for longer periods than open circuit Self contained breathing apparatus SCBA can provide air Crewed spacecraft and space suits outer space is effectively a vacuum without oxygen to support life Himalayan or high altitude mountaineering High altitude reduces the partial pressure of oxygen in the ambient air which reduces the ability of the climber to function effectively Mountaineering rebreathers are closed circuit oxygen sets that provide a higher partial pressure of oxygen to the climber than the ambient air Medical anaesthesia breathing systems to supply controlled concentrations of anaesthetic gases to patients without contaminating the air that the staff breathe and to conserve anaesthetic gas Life support systems of submarines underwater habitats and saturation diving systems use a scrubber system working on the same principles as a rebreather This may be compared with some applications of open circuit breathing apparatus The oxygen enrichment systems primarily used by medical patients high altitude mountaineers and commercial aircraft emergency systems in which the user breathes ambient air which is enriched by the addition of pure oxygen Open circuit breathing apparatus used by firefighters underwater divers and some mountaineers which supplies fresh gas for each breath which is then discharged into the environment Gas masks and respirators which filter contaminants from ambient air which is then breathed Diving rebreathers edit nbsp SIVA Underwater Mine Countermeasures MCM Diving Apparatus oxygen rebreather Main article Diving rebreather The widest variety of rebreather types is used in diving as the consequences of breathing under pressure complicate the requirements and a large range of options are available depending on the specific application and available budget A diving rebreather is safety critical life support equipment some modes of failure can kill the diver without warning others can require immediate appropriate response for survival Surface supplied diving gas reclaim systems edit See also Saturation diving Gas reclaim systems A helium reclaim system or push pull system is used to recover helium based breathing gas after use by the diver when this is more economical than losing it to the environment in open circuit systems The recovered gas is passed through a scrubber system to remove carbon dioxide filtered to remove odours and pressurised into storage containers where it may be mixed with oxygen to the required composition for re use either immediately or at a later date Saturation diving life support systems edit See also Saturation diving Life support systems The life support system provides breathing gas and other services to support life for the personnel under pressure in the accommodation chambers and closed diving bell It includes the following components 20 Breathing gas supply distribution and recycling equipment scrubbers filters boosters compressors mixing monitoring and storage facilities Chamber climate control system control of temperature and humidity and filtration of gas Instrumentation control monitoring and communications equipment Fire suppression systems Sanitation systemsThe life support system for the bell provides and monitors the main supply of breathing gas and the control station monitors the deployment and communications with the divers Primary gas supply power and communications to the bell are through a bell umbilical made up from a number of hoses and electrical cables twisted together and deployed as a unit 21 This is extended to the divers through the diver umbilicals 20 The accommodation life support system maintains the chamber environment within the acceptable range for health and comfort of the occupants Temperature humidity breathing gas quality sanitation systems and equipment function are monitored and controlled 21 Atmospheric diving suits edit nbsp US Navy atmospheric diving suitMain article Atmospheric diving suit An atmospheric diving suit is a small one man articulated submersible of roughly anthropomorphic form with limb joints which allow articulation under external pressure while maintaining an internal pressure of one atmosphere Breathing gas supply may be surface supplied by umbilical or from a rebreather carried on the suit An emergency gas supply rebreather may also be fitted to a suit with either surface supply or rebreather for primary breathing gas As the internal pressure is maintained at one atmosphere there is no risk of acute oxygen toxicity This is an underwater diving application but has more in common with industrial applications than with ambient pressure scuba rebreathers Industrial and rescue self contained rebreathers edit nbsp Mine rescue rebreathers in a Czech museumDifferent design criteria apply to SCBA rebreathers for use only out of the water There is no variation in ambient pressure on the components The counterlung may be placed for comfort and convenience Cooling of the gas in the breathing loop may be desirable as the absorbent produces heat as it reacts with carbon dioxide and the warming of the gas is not welcome in hot industrial situations such as firefighting and deep mines 22 Absorbent containers may in some cases rely on gravity for preventing channeling If a full face mask is used it may have viewports designed for convenience or improved field of vision and they do not need to be flat and parallel to prevent visual distortion as when underwater 22 In firefighting rebreathers consideration must be given to making the set reasonably flame proof and protecting it from heat and debris impacts 22 The need to ditch the set quickly may not arise and harness straps may not need a quick release Buoyancy is not a consideration but weight may be critical Good ergonomic design for ease of carrying comfort and balance are important where the unit may be worn in confined spaces while climbing and crawling through small gaps 22 A spring loaded counterlung pressurisation system may be used to provide slight positive pressure in the breathing loop to prevent noxious gas entry if the mask seal is not perfect 22 There are no constraints due to the physiological effects of breathing under pressure Complex gas mixtures are unnecessary Oxygen rebreathers can usually be used which makes the design considerably simpler and the mechanism more reliable A system allowing the user to access drinking water from a bag may be fitted A bite operated valve van be used to control flow 22 Radio voice communications may be fitted 22 A constant mass flow systen may be used to ensure a minimum fresh gas supply with a demand valve to add gas if the loop is emptied 22 Gas supply and absorbent duratio would usually be matched for efficiency 22 Insulation may be needed for the breathing loop for use in sub zero temperatures where freezing of the absorbent would reduce its effectiveness 22 A water trap may be provided to collect condensed water from the absorbent reaction and from metabolic product 22 Monitoring functions may include 22 Cylinder pressure analog and digital Estimated remaining duration of use until residual low pressure warning is activated Temperature indication Automatic recording of warning signals Optical and or acoustic warning signals may be provided for 22 Low gas pressure in the cylinder Alarm triggered by lack of user movement Manually triggered alarm Mountaineering rebreathers edit Mountaineering rebreathers provide oxygen at a higher concentration than available from atmospheric air in a naturally hypoxic environment They need to be lightweight and to be reliable in severe cold including not getting choked with deposited frost 23 A high rate of system failures due to extreme cold has not been solved citation needed Breathing pure oxygen results in an elevated partial pressure of oxygen in the blood a climber breathing pure oxygen at the summit of Mount Everest has a greater oxygen partial pressure than breathing air at sea level This results in being able to exert greater physical effort at altitude The exothermic reaction helps keep the scrubber contents from freezing and helps reduce heat loss from the user Both chemical and compressed gas oxygen have been used in experimental closed circuit oxygen systems the first on Mount Everest in 1938 The 1953 expedition used closed circuit oxygen equipment developed by Tom Bourdillon and his father for the first assault team of Bourdillon and Evans with one dural 800l compressed oxygen cylinder and soda lime canister the second successful assault team of Hillary and Tenzing used open circuit equipment 24 Rebreathers for unpressurised aircraft and high altitude parachuting edit Similar requirement and working environment to mountaineering but weight is less of a problem The Soviet IDA71 rebreather was also manufactured in a high altitude version which was operated as an oxygen rebreather Anaesthesia systems edit Main article Anaesthetic machine Anaesthetic machines can be configured as rebreathers to provide oxygen and anaesthetic gases to a patient during surgery or other procedures that require sedation An absorbent is present in the machine to remove the carbon dioxide from the loop 25 Both semi closed and fully closed circuit systems may be used for anaesthetic machines and both push pull pendulum two directional flow and one directional loop systems are used 26 The breathing circuit of a loop configured machine has two unidirectional valves so that only scrubbed gas flows to the patient while expired gas goes back to the machine 25 The anaesthetic machine can also provide gas to ventilated patients who cannot breathe on their own 27 A waste gas scavenging system removes any gasses from the operating room to avoid environmental contamination 28 Space suits edit nbsp Buzz Aldrin on the Moon on the 1969 Apollo 11 mission showing the portable life support system nbsp Orlan space suit on an EVA from the International Space Station with the life support umbilical in view Main article Space suit One of the functions of a space suit is to provide the wearer with breathing gas This can be done via an umbilical from the life support systems of the spacecraft or habitat or from a primary life support system carried on the suit Both of these systems involve rebreather technology as they both remove carbon dioxide from the breathing gas and add oxygen to compensate for oxygen used by the wearer Space suits usually use oxygen rebreathers as this allows a lower pressure in the suit which gives the wearer better freedom of movement Habitat life support systems edit See also Life support system Submarines underwater habitats bomb shelters space stations and other living spaces occupied by several people over medium to long periods on a limited gas supply are equivalent to closed circuit rebreathers in principle but generally rely on mechanical circulation of breathing gas through the scrubbers Safety editSee also Rebreather diving Safety There are several safety issues with rebreather equipment and these tend to be more severe in diving rebreathers Hazards edit Some of the hazards are due to the way the equipment works while others are related to the environment in which the equipment is used as rebreathers are usually used where no breathable ambient atmosphere is available Hypoxia edit Hypoxia can occur in any rebreather which contains enough inert gas to allow breathing without triggering automatic gas addition In an oxygen rebreather this can occur if the loop is not sufficiently purged at the start of use Purging is the replacement of the original gas content by fresh gas and may have to be repeated to completely remove inert gas Purging should be done while breathing off the unit so that the inert gas in the user s lungs and body tissues that finds its way into the loop is also removed from the system Carbon dioxide buildup edit Carbon dioxide buildup will occur if the scrubber medium is absent badly packed inadequate or exhausted The normal human body is fairly sensitive to carbon dioxide partial pressure and a buildup will be noticed by the user However there is not often much that can be done to rectify the problem except changing to another breathing gas supply until the scrubber can be repacked Continued use of a rebreather with an ineffective scrubber is not possible for very long as the levels will become toxic and the user will experience extreme respiratory distress followed by loss of consciousness and death The rate at which these problems develop depends on the volume of the circuit and the metabolic rate of the user at the time Carbon dioxide buildup can also occur when a combination of exertion and work of breathing exceeds the capacity of the user If this occurs where the user cannot reduce exertion sufficiently it may be impossible to correct This problem is more likely to occur with diving rebreathers at depths where the density of the breathing gas is severely elevated 29 30 31 Leakage of toxic gases into the breathing loop edit Industrial rebreathers are often used where the ambient air is contaminated and may be toxic Parts of the loop will be at a slightly lower than external ambient pressure during inhalation and if the circuit is not airtight external gases may leak in This is a particular issue around the edge of a full face mask where the rubber mask skirt must seal against the user s face Fire hazards of high concentration of oxygen edit High partial pressures of oxygen greatly increase fire hazard and many materials which are self extinguishing in atmospheric air will burn continuously in a high oxygen concentration This is more of a hazard for terrestrial applications such as rescue and firefighting than for diving where the ignition risk is relatively low Caustic cocktail edit Caused by a loop flood reaching the absorbent canister so only applicable in immersed applications Failure modes edit Further information Diving rebreather Failure modes Scrubber failure edit The term break through means the failure of the scrubber to continue removing sufficient carbon dioxide from the gas circulating in the loop This will inevitably happen if the scrubber is used too long but can happen prematurely in some circumstances There are several ways that the scrubber may fail or become less efficient Complete consumption of the active ingredient in a general break through Depending on scrubber design and user workload this may be gradual allowing the user to become aware of the problem in time to make a controlled exit or bailout to open circuit or relatively sudden triggering an urgent or emergency response Bypassing the absorbent The absorbent granules must be packed closely so that all exhaled gas comes into contact with the surface of soda lime and the canister is designed to avoid any large spaces or gaps between the absorbent granules or between the granules and the canister walls that would let gas bypass contact with the absorbent If any of the seals such as O rings or spacers that prevent bypassing of the scrubber are not present or not fitted properly or if the scrubber canister has been incorrectly packed or fitted it may allow the exhaled gas to bypass the absorbent and the scrubber will be less effective This failure mode is also called tunneling when absorbent settles to form void spaces inside the canister Bypass will cause an unexpected early break through When the gas mix is under pressure at depth the gas molecules are more densely packed and the carbon dioxide molecules mean path between collisions is shorter so they are not so free to move around to reach the absorbent surface and require a longer dwell time Because of this effect the scrubber must be bigger for deep diving than is needed for a shallow water industrial or high altitude rebreather Carbon dioxide absorbent can be caustic and can cause burns to the eyes mucous membranes and skin A mixture of water and absorbent occurs when the scrubber floods and depending on the chemicals used can produce a chalky taste or a burning sensation if the contaminated water reaches the mouthpiece which should prompt the diver to switch to an alternative source of breathing gas and rinse their mouth out with water This is known to rebreather divers as a caustic cocktail The excessive wetting of the absorbent also reduces the rate of carbon dioxide removal and can cause premature break through even if no caustic liquid reaches the diver Work of breathing may also increase Many modern diving rebreather absorbents are designed not to produce this caustic fluid if they get wet clarification needed In below freezing operation primarily mountain climbing wet scrubber chemicals can freeze when oxygen bottles are changed while there is a pause in the exothermic reaction of taking up the carbon dioxide thus preventing carbon dioxide from reaching the scrubber material and slowing the reaction when used again Other failure modes edit Flooding of the ambient pressure volume can occur in diving rebreathers Gas leakage to or from the ambient pressure volume can occur Since the volume of gas lost or gained is likely to be very small it is most relevant when the surroundings contain toxic gases or fumes Oxygen monitoring failure can lead to incorrect partial pressure of oxygen in the breathing gas This is only relevant in mixed gas rebreathers used for diving Gas injection system failure is also mainly a problem of mixed gas diving rebreathers Oxygen rebreathers gas injection systems are generally robust and reliable and can be manually overridden if they fail and this form of failure is identifiable by an inappropriate volume of gas in the ambient pressure volume of the rebreather History editSee also Timeline of diving technology Early history edit Around 1620 Cornelius Drebbel discovered that heating saltpetre potassium nitrate would generate oxygen 32 The first basic rebreather based on carbon dioxide absorption was patented in France in 1808 by Pierre Marie Touboulic from Brest a mechanic in Napoleon s Imperial Navy This early rebreather design worked with an oxygen reservoir the oxygen being delivered progressively by the diver and circulating in a closed circuit through a sponge soaked in limewater a solution of calcium hydroxide in water 33 34 Touboulic called his invention Ichtioandre Greek for fish man 35 citation needed There is no evidence of a prototype having been manufactured A prototype rebreather was built in 1849 by Pierre Aimable De Saint Simon Sicard 36 In 1853 Professor T Schwann presented a rebreather at the Belgian Academy of Science 37 34 It had a large back mounted oxygen tank with working pressure of about 13 3 bar and two scrubbers containing sponges soaked in a caustic soda solution 34 Working rebreathers edit nbsp Henry Fleuss inventor of the rebreatherThe first commercially practical closed circuit scuba was designed and built by the diving engineer Henry Fleuss in 1878 while working for Siebe Gorman in London 38 11 His self contained breathing apparatus consisted of a rubber mask connected to a breathing bag with estimated 50 60 O2 supplied from a copper tank and CO2 scrubbed by rope yarn soaked in a solution of caustic potash the system giving a duration of about three hours 11 39 Fleuss tested his device in 1879 by spending an hour submerged in a water tank then one week later by diving to a depth of 5 5 m in open water upon which occasion he was slightly injured when his assistants abruptly pulled him to the surface His apparatus was first used under operational conditions in 1880 by Alexander Lambert the lead diver on the Severn Tunnel construction project who was able to travel 1000 feet in the darkness to close several submerged sluice doors in the tunnel this had defeated his best efforts with standard diving dress due to the danger of the air supply hose becoming fouled on submerged debris and the strong water currents in the workings 11 In 1880 Fleuss used a rebreather to inspect Seaham Colliery in the UK after a gas explosion 34 Fleuss and Siebe Gorban developed the Proto breathing apparatus for mine rescue in 1911 34 Fleuss continually improved his apparatus adding a demand regulator and tanks capable of holding greater amounts of oxygen at higher pressure Sir Robert Davis head of Siebe Gorman improved the oxygen rebreather in 1910 11 39 with his invention of the Davis Submerged Escape Apparatus the first practical rebreather to be made in quantity While intended primarily as an emergency escape apparatus for submarine crews it was soon also used for diving being a handy shallow water diving apparatus with a thirty minute endurance 39 and as an industrial breathing set nbsp Davis Submerged Escape Apparatus being tested at the submarine escape test tank at HMS Dolphin Gosport 14 December 1942The rig comprised a rubber breathing buoyancy bag containing a canister of barium hydroxide to scrub exhaled CO2 and in a pocket at the lower end of the bag a steel pressure cylinder holding approximately 56 litres of oxygen at a pressure of 120 bar The cylinder was equipped with a control valve and was connected to the breathing bag Opening the cylinder s valve admitted oxygen to the bag and charged it to the pressure of the surrounding water The rig also included an emergency buoyancy bag on the front of to help keep the wearer afloat The DSEA was adopted by the Royal Navy after further development by Davis in 1927 40 Various industrial oxygen rebreathers such as the Siebe Gorman Salvus and the Siebe Gorman Proto both invented in the early 1900s were derived from it Professor Georges Jaubert invented the chemical compound Oxylithe in 1907 It was a form of sodium peroxide Na2O2 or sodium superoxide NaO2 As it absorbs carbon dioxide in a rebreather s scrubber it emits oxygen This compound was first incorporated into a rebreather design by Captain S S Hall and Dr O Rees of the Royal Navy in 1909 Although intended for use as a submarine escape apparatus it was never accepted by the Royal Navy and was instead used for shallow water diving 39 In 1912 the German firm Drager began mass production of their own version of standard diving dress with the air supply from a rebreather The apparatus had been invented some years earlier by Hermann Stelzner an engineer at the Drager company 41 for mine rescue 42 In the 1930s after some tragic accidents in the 1920s the United States Navy began to equip Porpoise and Salmon class submarines with primitiv rebreathers called Momsen lungs which where in use until the 1960s Rebreathers during World War II edit Further information Frogman nbsp A 1945 Royal Navy frogman with Davis apparatusIn the 1930s Italian sport spearfishers began to use the Davis rebreather Italian manufacturers received a licence from the English patent holders to produce it This practice soon came to the attention of the Italian Navy which developed an extensively upgraded model designed by Teseo Tesei and Angelo Belloni it that was used by its frogman unit Decima Flottiglia MAS with good results during World War II 39 During the Second World War captured Italian frogmen s rebreathers influenced improved designs for British rebreathers 39 Many British frogmen s breathing sets used aircrew breathing oxygen cylinders salvaged from shot down German Luftwaffe aircraft The earliest of these breathing sets may have been modified Davis Submerged Escape Apparatus their fullface masks were the type intended for the Siebe Gorman Salvus but in later operations different designs were used leading to a fullface mask with one big face window at first circular or oval and later rectangular mostly flat but the sides curved back to allow better vision sideways Early British frogman s rebreathers had rectangular counterlungs on the chest like Italian frogman s rebreathers but later designs had a square recess in the top of the counterlung so it could extend further up toward the shoulders In front they had a rubber collar that was clamped around the absorbent canister 39 Some British armed forces divers used bulky thick diving suits called Sladen suits one version of it had a flip up single faceplate for both eyes to let the user get binoculars to his eyes when on the surface The Drager rebreathers especially the DM20 and DM40 model series were used by the German helmet divers and German frogmen during World War II Rebreathers for the US Navy were developed by Dr Christian J Lambertsen for underwater warfare 43 44 Lambertsen held the first closed circuit oxygen rebreather course in the United States for the Office of Strategic Services maritime unit at the Naval Academy on 17 May 1943 44 45 During and after WWII needs arose in the armed forces to dive deeper than allowed by pure oxygen That prompted at least in Britain design of simple constant flow mixture rebreather variants of some of their diving oxygen rebreathers what is now called nitrox SCMBA from the SCBA Swimmer Canoeist s Breathing Apparatus and CDMBA from the Siebe Gorman CDBA by adding an extra gas supply cylinder Before a dive with such a set the diver had to know the maximum or working depth of his dive and how fast his body used his oxygen supply and from those to calculate what to set his rebreather s gas flow rate to Post WWII edit The diving pioneer Hans Hass used Drager oxygen rebreathers in the early 1940s for underwater cinematography Due to the military importance of the rebreather amply demonstrated during the naval campaigns of the Second World War most governments were reluctant to issue the technology into the public domain In Britain rebreather use for civilians was negligible and the BSAC formally prohibited rebreather use by its members The Italian firms Pirelli and Cressi Sub at first each sold a model of sport diving rebreather but after a while discontinued those models Some home made rebreathers were used by cave divers to penetrate cave sumps Most high altitude mountaineers use open circuit oxygen equipment the 1953 Everest expedition used both closed circuit and open circuit oxygen equipment see bottled oxygen Eventually the Cold War ended and in 1989 the Communist Bloc collapsed and as a result the perceived risk of sabotage attacks by combat divers dwindled and Western armed forces had less reason to requisition civilian rebreather patents and automatic and semi automatic recreational diving rebreathers with oxygen partial pressure sensors started to appear Manufacturers and models editFor diving rebreather makes and models see Diving rebreather Manufacturers and models Industrial rescue Blackett s Aerophor A nitrox semi closed circuit rebreather with liquid gas storage made in England from 1910 onwards for use in mine rescue and other industrial uses citation needed Sabre Safety SEFA Selected Elevated Flow Apparatus an industrial oxygen rebreather formerly made by Sabre Safety with 2 hours duration on a filling citation needed Siebe Gorman British manufacturer of diving equipment and salvage contractor The Savox was an oxygen rebreather with a use duration of 45 minutes It had no hard casing and was worn in front of the body 15 Siebe Gorman Salvus Industrial rescue and shallow water oxygen rebreather IDA71 Russian military rebreather for underwater and high altitude useOthers This section needs expansion You can help by adding to it October 2022 See also editCarbon dioxide scrubber Device which absorbs carbon dioxide from circulated gas Escape set Self contained breathing apparatus providing gas to escape from a hazardous environmentPages displaying short descriptions of redirect targets Primary life support system also known as Portable Life Support System Life support device for a space suit Self contained breathing apparatus SCBA Breathing gas supply system carried by the user surface only industrial breathing sets including rebreathers References edit a b NOAA Diving Program U S 28 Feb 2001 Joiner James T ed NOAA Diving Manual Diving for Science and Technology 4th ed Silver Spring Maryland National Oceanic and Atmospheric Administration Office of Oceanic and Atmospheric Research National Undersea Research Program ISBN 978 0 941332 70 5 CD ROM prepared and distributed by the National Technical Information Service NTIS in partnership with NOAA and Best Publishing Company Dhami P S Chopra G Shrivastava H N 2015 A Textbook of Biology Jalandhar Punjab Pradeep Publications pp V 101 US Navy 1 December 2016 U S Navy Diving Manual Revision 7 SS521 AG PRO 010 0910 LP 115 1921 PDF Washington DC US Naval Sea Systems Command Chapter 15 Electronically Controlled Closed Circuit Underwater Breathing Apparatus EC UBA Diving Section 15 2 Principles of operation a b US Navy Diving Manual 2016 Chapter 15 Electronically Controlled Closed Circuit Underwater Breathing Apparatus EC UBA Diving Section 15 2 Principles of operation James W Miller ed 1979 Fig 2 4 NOAA Diving Manual 2nd ed Washington DC US Dept of Commerce National Oceanographic and Atmospheric Administration pp 2 7 a b c d e Odom J August 1999 An Introduction to Semi Closed Circuit Rebreathers The Drager Series of Recreational Rebreathers PDF Revision 4a ed Technical Diving International 1995 Gant Nicholas van Waart Hanna Ashworth Edward T Mesley Peter Mitchell Simon J December 2019 Performance of cartridge and granular carbon dioxide absorbents in a closed circuit diving rebreather Diving and Hyperbaric Medicine 49 4 298 303 doi 10 28920 dhm49 4 298 303 PMC 7039778 PMID 31828749 a b c d Sandham John ed 2009 EBME amp Clinical Engineering Articles Soda lime production www ebme co uk Retrieved 24 October 2022 Greenwood Norman N Earnshaw Alan 1984 Chemistry of the Elements Oxford Pergamon Press ISBN 978 0 08 022057 4 Older P 1969 Theoretical Considerations in the Design of Closed Circuit Oxygen Rebreathing Equipment Royal Australian Navy School of Underwater Medicine RANSUM 4 69 Archived from the original on May 9 2008 Retrieved 2008 06 14 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint unfit URL link a b c d e Davis RH 1955 Deep Diving and Submarine Operations 6th ed Tolworth Surbiton Surrey Siebe Gorman amp Company Ltd p 693 US Navy 2006 Chapter 19 Closed Circuit Oxygen UBA Diving US Navy Diving Manual 6th revision United States US Naval Sea Systems Command pp 19 9 Retrieved 2008 06 15 Kelley JS Herron JM Dean WW Sundstrom EB 1968 Mechanical and Operational Tests of a Russian Superoxide Rebreather US Navy Experimental Diving Unit Technical Report NEDU Evaluation 11 68 Archived from the original on May 9 2008 Retrieved 2009 01 31 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint unfit URL link Holquist Jordan B Klaus David M Graf John C 13 17 July 2014 Characterization of Potassium Superoxide and a Novel Packed Bed Configuration for Closed Environment Air Revitalization PDF 44th International Conference on Environmental Systems ICES 2014 192 Tucson Arizona a b Robinson Brian Taylor Fionn ed Breathing Apparatus Bob s History of Mining Retrieved 27 December 2013 Richardson Drew Menduno Michael Shreeves Karl 1996 Proceedings of Rebreather Forum 2 0 Diving Science and Technology Workshop 286 Archived from the original on September 15 2008 Retrieved 2008 08 20 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint unfit URL link DESCO 29019 U S Navy Helium Diving Helmet w Double Exhaust Valve DESCO Retrieved 2 July 2019 Going deep divingheritage com Retrieved 2 July 2019 The OBS A S reclaim helmet DiveScrap Index the scrapbook of diving history Retrieved 2 July 2019 a b Crawford J 2016 8 5 1 Helium recovery systems Offshore Installation Practice revised ed Butterworth Heinemann pp 150 155 ISBN 9781483163192 a b Staff US Navy 2006 15 US Navy Diving Manual 6th revision United States US Naval Sea Systems Command Retrieved 15 June 2008 a b c d e f g h i j k l m Drager PSS BG 4 plus Breathing Apparatus PDF www draeger com Retrieved 30 October 2022 Hendricks David M Pollock Neal W Natoli Michael J Hobbs Gene W Gabrielova Ivana Vann Richard D 1999 Mountaineering oxygen mask efficiency at 4572 m In Roach RC Wagner PD Hackett PH Hypoxia Into the Next Millennium Advances in Experimental Medicine and Biology Series Kluwer Academic New York 387 388 Hunt John 1953 The Ascent of Everest London Hodder amp Stoughton pp 257 262 a b staff 2003 08 18 Breathing Circuit University of Florida Retrieved 2013 04 25 Ravishankar M Anesthesia breathing machines an in depth review www capnography com Archived from the original on 17 May 2013 Retrieved 30 April 2013 staff 2003 08 18 Mechanical and Manual Ventilation Systems University of Florida Retrieved 2013 04 25 staff 2003 08 18 The Scavenging System University of Florida Retrieved 2013 04 25 Mitchell Simon J Cronje Frans J Meintjes W A Jack Britz Hermie C 2007 Fatal Respiratory Failure During a Technical Rebreather Dive at Extreme Pressure Aviation Space and Environmental Medicine 78 2 81 86 PMID 17310877 Retrieved 21 November 2019 Mitchell Simon August 2008 Four Carbon Dioxide Retention In Mount Tom Dituri Joseph eds Exploration and Mixed Gas Diving Encyclopedia 1st ed Miami Shores Florida International Association of Nitrox Divers pp 279 286 ISBN 978 0 915539 10 9 Mitchell Simon 2015 Respiratory failure in technical diving www youtube com DAN Southern Africa Retrieved 6 October 2021 Cornelius Drebbel inventor of the submarine Dutch Submarines Archived from the original on 2012 05 30 Retrieved 2008 02 23 Bahuet Eric 19 October 2003 Avec ou sans bulles With or without bubbles La Plongee Souterrain in French plongeesout com Introduction Retrieved 5 February 2017 a b c d e Breathing apparatus in mining Don t hold your breath Australian Mine Safety Journal 19 October 2020 Retrieved 31 October 2022 Bahuet Eric L Ichtioandre illistration La Plongee Souterrain in French plongeesout com Retrieved 5 February 2017 Saint Simon Sicard s invention as mentioned by the Musee du Scaphandre website a diving museum in Espalion south of France Bech Janwillem Theodor Schwann Retrieved 2008 02 23 Henry Albert Fleuss scubahalloffame com Archived from the original on 2015 01 12 a b c d e f g Quick D 1970 A History Of Closed Circuit Oxygen Underwater Breathing Apparatus Royal Australian Navy School of Underwater Medicine RANSUM 1 70 Archived from the original on May 9 2008 Retrieved 2009 03 03 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint unfit URL link Paul Kemp 1990 The T Class submarine The Classic British Design Arms and Armour p 105 ISBN 0 85368 958 X Drager diving helmets Dragerwerk www divingheritage com Retrieved 12 December 2016 Bech Janwillem ed Photos Draeger 1907 Rescue Apparatus Retrieved 19 December 2017 Vann RD 2004 Lambertsen and O2 beginnings of operational physiology Undersea Hyperb Med 31 1 21 31 PMID 15233157 Archived from the original on June 13 2008 Retrieved 2008 04 25 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint unfit URL link a b Butler F K 2004 Closed circuit oxygen diving in the U S Navy Undersea Hyperb Med 31 1 3 20 PMID 15233156 Archived from the original on June 13 2008 Retrieved 2008 04 25 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint unfit URL link Hawkins T Jan Mar 2000 OSS Maritime The Blast 32 1 External links edit nbsp Media related to Rebreathers at Wikimedia Commons Anesthesia breathing systems NIOSH Docket 123 titled Reevaluation of NIOSH limitations on and precaution for safe use of positive pressure closed circuit SCBA is available at web archive org Retrieved from https en wikipedia org w index php title Rebreather amp oldid 1186340274 Loop, wikipedia, wiki, book, books, library,