fbpx
Wikipedia

Pumping station

Pumping stations, also called pumphouses,[1] are public utility buildings containing pumps and equipment for pumping fluids from one place to another. They are critical in a variety of infrastructure systems, such as water supply, drainage of low-lying land, canals and removal of sewage to processing sites. A pumping station is an integral part of a pumped-storage hydroelectricity installation.

Pumping station Van Sasse in Grave, Netherlands.
Pumping station Van Sasse in Grave, the Netherlands.

Pumping stations are designed to move water or sewage from one location to another, overcoming gravitational challenges, and are essential for maintaining navigable canal levels, supplying water, and managing sewage and floodwaters. In canal systems, pumping stations help replenish water lost through lock usage and leakage, ensuring navigability. Similarly, in land drainage, stations pump water to prevent flooding in areas below sea level, a concept pioneered during the Victorian era in places like The Fens in the UK. The introduction of "package pumping stations" has modernized drainage systems, allowing a compact, efficient solution for areas where gravity drainage is impractical.

Water pumping stations are differentiated by their applications, such as sourcing from wells, raw water pumping, and high service pumping, each designed to meet specific demand projections and customer needs. Wastewater pumping stations, on the other hand, are engineered to handle sewage, with designs that ensure reliability and safety, minimizing environmental impacts from overflows. Innovations in pump technology and station design have led to the development of submersible pump stations, which are more compact and safer, effectively reducing the footprint and visibility of sewage management infrastructure. Electronic controllers have enhanced the efficiency and monitoring capabilities of pumping stations, essential for modern systems. Pumped-storage schemes represent a critical use of pumping stations, providing a method for energy storage and generation by moving water between reservoirs at different elevations, highlighting the versatility and importance of pumping stations across sectors.

Some pumping stations have been recognized for their architectural and historical significance, e.g. the Claverton and Crofton Pumping Stations, are preserved as museum attractions. Examples such as land drainage in the Netherlands water supply in Hong Kong and agricultural drainage in Iraq, underscore the vital role these facilities play in supporting modern infrastructure, environmental management, and energy storage.

Canal water supply edit

In countries with canal systems, pumping stations are also frequent. Because of the way the system of canal locks work, water is lost from the upper part of a canal each time a vessel passes through. Also, most lock gates are not watertight, so some water leaks from the higher levels of the canal to those lower down. The water has to be replaced or eventually the upper levels of the canal would not hold enough water to be navigable.

Canals are usually fed by diverting water from streams and rivers into the upper parts of the canal, but if no suitable source is available, a pumping station can be used to maintain the water level. An example of a canal pumping station is the Claverton Pumping Station on the Kennet and Avon Canal in southern England, United Kingdom. This pumps water from the nearby River Avon to the canal using pumps driven by a waterwheel which is powered by the river.[2]

Where no external water supply is available, back pumping systems may be employed. Water is extracted from the canal below the lowest lock of a flight and is pumped back to the top of the flight, ready for the next boat to pass through. Such installations are usually small.

Land drainage edit

 
New Orleans, Louisiana: Metairie Pumping Station, also known as Pumping Station 6, building, constructed in 1899, near Metairie Road and the head of the 17th Street Canal. Now housing 15 Wood Screw Pumps, it can move over 6 billion US gallons (23,000,000 m3) of water a day.[citation needed]

When low-lying areas of land are drained, the general method is to dig drainage ditches. However, if the area is below sea level then it is necessary to pump the water upwards into water channels that finally drain into the sea.

The Victorians understood this concept, and in the United Kingdom they built pumping stations with water pumps, powered by steam engines to accomplish this task. In Lincolnshire, large areas of wetland at sea level, called The Fens, were turned into rich arable farmland by this method. The land is full of nutrients because of the accumulation of sedimentary mud that created the land initially.

 
A land drainage pumping station in Sète, France.

Elsewhere, pumping stations are used to remove water that has found its way into low-lying areas as a result of leakage or flooding (in New Orleans, for example).

Package pumping station edit

In more recent times, a "package pumping station" provides an efficient and economic way of installing a drainage system. They are suitable for mechanical building services collection and pumping of liquids like surface water, wastewater or sewage from areas where drainage by gravity is not possible.

A package pumping station is an integrated system, built in a housing manufactured from strong, impact-resistant materials such as precast concrete, polyethylene, or glass-reinforced plastic. The unit is supplied with internal pipework fitted, pre-assembled ready for installation into the ground, after which the submersible pumps and control equipment are fitted. Features may include controls for fully automatic operation; a high-level alarm indication, in the event of pump failure; and possibly a guide-rail/auto-coupling/pedestal system, to permit easy removal of pumps for maintenance.

Traditional site constructed systems have the valve vault components installed in a separate structure. Having two structural components can lead to potentially serious site problems such as uneven settling between components which results in stress on, and failure of the pipes and connections between components. The development of a packaged pump station system combined all components into a single housing which not only eliminates uneven settling issues, but pre-plumbing and outfitting each unit prior to installation can reduce the cost and time involved with civil work and site labor.

Water pumping stations edit

Water pumping stations are differentiated from wastewater pumping stations in that they do not have to be sized to account for high peak flow rates. They have five general categories:[3]

  • Source (such as a well) pump discharging into an elevated tank
  • Raw water pumping from a river or lake
  • In-line booster pumping into an elevated tank
  • High service pumping of finished water at high pressure
  • Distributed system booster without a storage tank in the piping system

Water pumping stations are constructed in areas in which the demand or projected demand is reasonably defined, and is dependent on a combination of customer needs and fire flow requirements. Average annual per-capita water consumption, peak hour, and maximum daily can vary greatly due to factors such as climate, income levels, population, and the proportions of residential, commercial, and industrial users.[3]

Wastewater pumping stations edit

 
The now flooded C Station at Abbey Mills in London. The concrete platforms used to house large motor / pump assemblies that brought sewage up from a deep main drain into several outfall sewers, taking it away from the city centre.

Pumping stations in sewage collection systems are normally designed to handle raw sewage that is fed from underground gravity pipelines (pipes that are sloped so that a liquid can flow in one direction under gravity). Sewage is fed into and stored in a pit, commonly known as a wet well. The well is equipped with electrical instrumentation to detect the level of sewage present. When the sewage level rises to a predetermined point, a pump will be started to lift the sewage upward through a pressurized pipe system called a sewer force main if the sewage is transported some significant distance. The pumping station may be called a lift station if the pump merely discharges into a nearby gravity manhole.[4] From here the cycle starts all over again until the sewage reaches its point of destination—usually a treatment plant. By this method, pumping stations are used to move waste to higher elevations. In the case of high sewage flows into the well (for example during peak flow periods and wet weather) additional pumps will be used. If this is insufficient, or in the case of failure of the pumping station, a backup in the sewer system can occur, leading to a sanitary sewer overflow—the discharge of raw sewage into the environment.

Sewage pumping stations are typically designed so that one pump or one set of pumps will handle normal peak flow conditions. Redundancy is built into the system so that in the event that any one pump is out of service, the remaining pump or pumps will handle the designed flow. The storage volume of the wet well between the "pump on" and "pump off" settings is designed to minimize pump starts and stops, but is not so long a retention time as to allow the sewage in the wet well to go septic.

Sewage pumps are almost always end-suction centrifugal pumps with open impellers and are specially designed with a large open passage so as to avoid clogging with debris or winding stringy debris onto the impeller. A four pole or six pole AC induction motor normally drives the pump. Rather than provide large open passages, some pumps, typically smaller sewage pumps, also macerate any solids within the sewage breaking them down into smaller parts which can more easily pass through the impeller.

The interior of a sewage pump station is a very dangerous place. Poisonous gases, such as methane and hydrogen sulfide, can accumulate in the wet well; an ill-equipped person entering the well would be overcome by fumes very quickly. Any entry into the wet well requires the correct confined space entry method for a hazardous environment. To minimize the need for entry, the facility is normally designed to allow pumps and other equipment to be removed from outside the wet well.

Traditional sewage pumping stations incorporate both a wet well and a "dry well". Often these are the same structure separated by an internal divide. In this configuration pumps are installed below ground level on the base of the dry well so that their inlets are below water level on pump start, priming the pump and also maximising the available NPSH. Although nominally isolated from the sewage in the wet well, dry wells are underground, confined spaces and require appropriate precautions for entry. Further, any failure or leakage of the pumps or pipework can discharge sewage directly into the dry well with complete flooding not an uncommon occurrence. As a result, the electric motors are normally mounted above the overflow, top water level of the wet well, usually above ground level, and drive the sewage pumps through an extended vertical shaft. To protect the above ground motors from weather, small pump houses are normally built, which also incorporate the electrical switchgear and control electronics. These are the visible parts of a traditional sewage pumping station although they are typically smaller than the underground wet and dry wells.

More modern pumping stations do not require a dry well or pump house and usually consist only of a wet well. In this configuration, submersible sewage pumps with closely coupled electric motor are mounted within the wet well itself, submerged within the sewage. Submersible pumps are mounted on two vertical guide rails and seal onto a permanently fixed "duckfoot", which forms both a mount and also a vertical bend for the discharge pipe. For maintenance or replacement, submersible pumps are raised by a chain off of the duckfoot and up the two guide rails to the maintenance (normally ground) level. Reinstalling the pumps simply reverses this process with the pump being remounted on the guide rails and lowered onto the duckfoot where the weight of the pump reseals it. As the motors are sealed and weather is not a concern, no above ground structures are required, excepting a small kiosk to contain the electrical switchgear and control systems.

Due to the much reduced health and safety concerns, and smaller footprint and visibility, submersible pump sewage pumping stations have almost completely superseded traditional sewage pumping stations. Further, a refit of a traditional pumping station usually involves converting it into a modern pumping station by installing submersibles in the wet well, demolishing the pump house and retiring the dry well by either stripping it, or knocking down the internal partition and merging it with the wet well.

Electronic controllers edit

Pump manufacturers have always designed and manufactured electronic devices to control and supervise pumping stations. Today it is also very common to use a programmable logic controller (PLC) or Remote Terminal Unit (RTU) for such work, but the experience needed to solve certain particular problems, makes an easy choice to look for a specific pump controller. RTUs are very helpful in remote monitoring of each pumping station from a centralized control room with SCADA (Supervisory Control & Data Acquisition) systems. This setup can be helpful in monitoring pump faults, levels, and other alarms and parameters, making it more efficient.

Pumped-storage schemes edit

A pumped-storage scheme is a type of power station for storing and producing electricity to supply high peak demands by moving water between reservoirs at different elevations.

Typically, water is channeled from a high-level reservoir to a low-level reservoir, through turbine generators that generate electricity. This is done when the station is required to generate power. During low-demand periods, such as overnight, the generators are reversed to become pumps that move the water back up to the top reservoir.

List of pumping stations edit

There are countless thousands of pumping stations throughout the world. The following is a list of those described in this encyclopedia.

United Kingdom edit

In the UK, during the Victorian Era, there was a fashion for public buildings to feature highly ornate architecture. Consequently, a considerable number of former pumping stations have been listed and preserved. The majority were originally steam-powered, and where the steam engines are still in situ, many of the sites have since re-opened as museum attractions.

Canal water supply edit

Groundwater supply edit

Used to pump water from a well into a reservoir

Hydraulic power station edit

Land drainage edit

Public water supply edit

Used to pump drinking water from a reservoir into a water supply system.

Sewage edit

Underground railway edit

Hong Kong edit

Public water supply

Iraq edit

Agricultural drainage

Canada edit

  • Hamilton Museum of Steam and Technology, Hamilton, Ontario's first Water Works, powered by two 1859 steam engines

Netherlands edit

Land drainage

Spain edit

  • Stations for public water supply in Barcelona. One of them is a Barcelona City History Museum heritage site (MUHBA Casa de l'aigua).[5] Another is a museum itself: Museu Agbar de les Aigües (Agbar water museum).[6]

United States edit

See also edit

Waterworks railways edit

References edit

  1. ^ In situations such as drilled wells and drinking water
  2. ^ Jane Cumberlidge (2009). Inland Waterways of Great Britain (8th Ed.). Imray Laurie Norie and Wilson. p. 26. ISBN 978-1-84623-010-3.
  3. ^ a b Pumping Station Design. Jones, Garr M. (3rd ed.). Burlington, MA: Butterworth-Heinemann. 2006. p. 18.2. ISBN 978-0-08-094106-6. OCLC 144609617.{{cite book}}: CS1 maint: others (link)
  4. ^ Design and Construction of Sanitary and Storm Sewers. New York: American Society of Civil Engineers. 1970. p. 288.
  5. ^ "Barcelona City History Museum water pumping station Casa de l'Aigua".
  6. ^ "Agbar water museum".

External links edit

  • How To Choose The Right Pump To Suit Your Pumping Station
  • How to look after your packaged pumpstation
  • Prickwillow Museum
  • How Much Do Sewage Pumping Stations Cost

pumping, station, also, called, pumphouses, public, utility, buildings, containing, pumps, equipment, pumping, fluids, from, place, another, they, critical, variety, infrastructure, systems, such, water, supply, drainage, lying, land, canals, removal, sewage, . Pumping stations also called pumphouses 1 are public utility buildings containing pumps and equipment for pumping fluids from one place to another They are critical in a variety of infrastructure systems such as water supply drainage of low lying land canals and removal of sewage to processing sites A pumping station is an integral part of a pumped storage hydroelectricity installation Pumping station Van Sasse in Grave Netherlands Pumping station Van Sasse in Grave the Netherlands Pumping stations are designed to move water or sewage from one location to another overcoming gravitational challenges and are essential for maintaining navigable canal levels supplying water and managing sewage and floodwaters In canal systems pumping stations help replenish water lost through lock usage and leakage ensuring navigability Similarly in land drainage stations pump water to prevent flooding in areas below sea level a concept pioneered during the Victorian era in places like The Fens in the UK The introduction of package pumping stations has modernized drainage systems allowing a compact efficient solution for areas where gravity drainage is impractical Water pumping stations are differentiated by their applications such as sourcing from wells raw water pumping and high service pumping each designed to meet specific demand projections and customer needs Wastewater pumping stations on the other hand are engineered to handle sewage with designs that ensure reliability and safety minimizing environmental impacts from overflows Innovations in pump technology and station design have led to the development of submersible pump stations which are more compact and safer effectively reducing the footprint and visibility of sewage management infrastructure Electronic controllers have enhanced the efficiency and monitoring capabilities of pumping stations essential for modern systems Pumped storage schemes represent a critical use of pumping stations providing a method for energy storage and generation by moving water between reservoirs at different elevations highlighting the versatility and importance of pumping stations across sectors Some pumping stations have been recognized for their architectural and historical significance e g the Claverton and Crofton Pumping Stations are preserved as museum attractions Examples such as land drainage in the Netherlands water supply in Hong Kong and agricultural drainage in Iraq underscore the vital role these facilities play in supporting modern infrastructure environmental management and energy storage Contents 1 Canal water supply 2 Land drainage 2 1 Package pumping station 3 Water pumping stations 4 Wastewater pumping stations 5 Electronic controllers 6 Pumped storage schemes 7 List of pumping stations 7 1 United Kingdom 7 1 1 Canal water supply 7 1 2 Groundwater supply 7 1 3 Hydraulic power station 7 1 4 Land drainage 7 1 5 Public water supply 7 1 6 Sewage 7 1 7 Underground railway 7 2 Hong Kong 7 3 Iraq 7 4 Canada 7 5 Netherlands 7 6 Spain 7 7 United States 8 See also 8 1 Waterworks railways 9 References 10 External linksCanal water supply editIn countries with canal systems pumping stations are also frequent Because of the way the system of canal locks work water is lost from the upper part of a canal each time a vessel passes through Also most lock gates are not watertight so some water leaks from the higher levels of the canal to those lower down The water has to be replaced or eventually the upper levels of the canal would not hold enough water to be navigable Canals are usually fed by diverting water from streams and rivers into the upper parts of the canal but if no suitable source is available a pumping station can be used to maintain the water level An example of a canal pumping station is the Claverton Pumping Station on the Kennet and Avon Canal in southern England United Kingdom This pumps water from the nearby River Avon to the canal using pumps driven by a waterwheel which is powered by the river 2 Where no external water supply is available back pumping systems may be employed Water is extracted from the canal below the lowest lock of a flight and is pumped back to the top of the flight ready for the next boat to pass through Such installations are usually small Land drainage edit nbsp New Orleans Louisiana Metairie Pumping Station also known as Pumping Station 6 building constructed in 1899 near Metairie Road and the head of the 17th Street Canal Now housing 15 Wood Screw Pumps it can move over 6 billion US gallons 23 000 000 m3 of water a day citation needed When low lying areas of land are drained the general method is to dig drainage ditches However if the area is below sea level then it is necessary to pump the water upwards into water channels that finally drain into the sea The Victorians understood this concept and in the United Kingdom they built pumping stations with water pumps powered by steam engines to accomplish this task In Lincolnshire large areas of wetland at sea level called The Fens were turned into rich arable farmland by this method The land is full of nutrients because of the accumulation of sedimentary mud that created the land initially nbsp A land drainage pumping station in Sete France Elsewhere pumping stations are used to remove water that has found its way into low lying areas as a result of leakage or flooding in New Orleans for example Package pumping station edit In more recent times a package pumping station provides an efficient and economic way of installing a drainage system They are suitable for mechanical building services collection and pumping of liquids like surface water wastewater or sewage from areas where drainage by gravity is not possible A package pumping station is an integrated system built in a housing manufactured from strong impact resistant materials such as precast concrete polyethylene or glass reinforced plastic The unit is supplied with internal pipework fitted pre assembled ready for installation into the ground after which the submersible pumps and control equipment are fitted Features may include controls for fully automatic operation a high level alarm indication in the event of pump failure and possibly a guide rail auto coupling pedestal system to permit easy removal of pumps for maintenance Traditional site constructed systems have the valve vault components installed in a separate structure Having two structural components can lead to potentially serious site problems such as uneven settling between components which results in stress on and failure of the pipes and connections between components The development of a packaged pump station system combined all components into a single housing which not only eliminates uneven settling issues but pre plumbing and outfitting each unit prior to installation can reduce the cost and time involved with civil work and site labor Water pumping stations editWater pumping stations are differentiated from wastewater pumping stations in that they do not have to be sized to account for high peak flow rates They have five general categories 3 Source such as a well pump discharging into an elevated tank Raw water pumping from a river or lake In line booster pumping into an elevated tank High service pumping of finished water at high pressure Distributed system booster without a storage tank in the piping systemWater pumping stations are constructed in areas in which the demand or projected demand is reasonably defined and is dependent on a combination of customer needs and fire flow requirements Average annual per capita water consumption peak hour and maximum daily can vary greatly due to factors such as climate income levels population and the proportions of residential commercial and industrial users 3 Wastewater pumping stations edit nbsp The now flooded C Station at Abbey Mills in London The concrete platforms used to house large motor pump assemblies that brought sewage up from a deep main drain into several outfall sewers taking it away from the city centre Pumping stations in sewage collection systems are normally designed to handle raw sewage that is fed from underground gravity pipelines pipes that are sloped so that a liquid can flow in one direction under gravity Sewage is fed into and stored in a pit commonly known as a wet well The well is equipped with electrical instrumentation to detect the level of sewage present When the sewage level rises to a predetermined point a pump will be started to lift the sewage upward through a pressurized pipe system called a sewer force main if the sewage is transported some significant distance The pumping station may be called a lift station if the pump merely discharges into a nearby gravity manhole 4 From here the cycle starts all over again until the sewage reaches its point of destination usually a treatment plant By this method pumping stations are used to move waste to higher elevations In the case of high sewage flows into the well for example during peak flow periods and wet weather additional pumps will be used If this is insufficient or in the case of failure of the pumping station a backup in the sewer system can occur leading to a sanitary sewer overflow the discharge of raw sewage into the environment Sewage pumping stations are typically designed so that one pump or one set of pumps will handle normal peak flow conditions Redundancy is built into the system so that in the event that any one pump is out of service the remaining pump or pumps will handle the designed flow The storage volume of the wet well between the pump on and pump off settings is designed to minimize pump starts and stops but is not so long a retention time as to allow the sewage in the wet well to go septic Sewage pumps are almost always end suction centrifugal pumps with open impellers and are specially designed with a large open passage so as to avoid clogging with debris or winding stringy debris onto the impeller A four pole or six pole AC induction motor normally drives the pump Rather than provide large open passages some pumps typically smaller sewage pumps also macerate any solids within the sewage breaking them down into smaller parts which can more easily pass through the impeller The interior of a sewage pump station is a very dangerous place Poisonous gases such as methane and hydrogen sulfide can accumulate in the wet well an ill equipped person entering the well would be overcome by fumes very quickly Any entry into the wet well requires the correct confined space entry method for a hazardous environment To minimize the need for entry the facility is normally designed to allow pumps and other equipment to be removed from outside the wet well Traditional sewage pumping stations incorporate both a wet well and a dry well Often these are the same structure separated by an internal divide In this configuration pumps are installed below ground level on the base of the dry well so that their inlets are below water level on pump start priming the pump and also maximising the available NPSH Although nominally isolated from the sewage in the wet well dry wells are underground confined spaces and require appropriate precautions for entry Further any failure or leakage of the pumps or pipework can discharge sewage directly into the dry well with complete flooding not an uncommon occurrence As a result the electric motors are normally mounted above the overflow top water level of the wet well usually above ground level and drive the sewage pumps through an extended vertical shaft To protect the above ground motors from weather small pump houses are normally built which also incorporate the electrical switchgear and control electronics These are the visible parts of a traditional sewage pumping station although they are typically smaller than the underground wet and dry wells More modern pumping stations do not require a dry well or pump house and usually consist only of a wet well In this configuration submersible sewage pumps with closely coupled electric motor are mounted within the wet well itself submerged within the sewage Submersible pumps are mounted on two vertical guide rails and seal onto a permanently fixed duckfoot which forms both a mount and also a vertical bend for the discharge pipe For maintenance or replacement submersible pumps are raised by a chain off of the duckfoot and up the two guide rails to the maintenance normally ground level Reinstalling the pumps simply reverses this process with the pump being remounted on the guide rails and lowered onto the duckfoot where the weight of the pump reseals it As the motors are sealed and weather is not a concern no above ground structures are required excepting a small kiosk to contain the electrical switchgear and control systems Due to the much reduced health and safety concerns and smaller footprint and visibility submersible pump sewage pumping stations have almost completely superseded traditional sewage pumping stations Further a refit of a traditional pumping station usually involves converting it into a modern pumping station by installing submersibles in the wet well demolishing the pump house and retiring the dry well by either stripping it or knocking down the internal partition and merging it with the wet well Electronic controllers editPump manufacturers have always designed and manufactured electronic devices to control and supervise pumping stations Today it is also very common to use a programmable logic controller PLC or Remote Terminal Unit RTU for such work but the experience needed to solve certain particular problems makes an easy choice to look for a specific pump controller RTUs are very helpful in remote monitoring of each pumping station from a centralized control room with SCADA Supervisory Control amp Data Acquisition systems This setup can be helpful in monitoring pump faults levels and other alarms and parameters making it more efficient Pumped storage schemes editMain article Pumped storage hydroelectricity A pumped storage scheme is a type of power station for storing and producing electricity to supply high peak demands by moving water between reservoirs at different elevations Typically water is channeled from a high level reservoir to a low level reservoir through turbine generators that generate electricity This is done when the station is required to generate power During low demand periods such as overnight the generators are reversed to become pumps that move the water back up to the top reservoir See also List of pumped storage hydroelectric power stationsList of pumping stations editThere are countless thousands of pumping stations throughout the world The following is a list of those described in this encyclopedia United Kingdom edit In the UK during the Victorian Era there was a fashion for public buildings to feature highly ornate architecture Consequently a considerable number of former pumping stations have been listed and preserved The majority were originally steam powered and where the steam engines are still in situ many of the sites have since re opened as museum attractions Canal water supply edit Claverton Pumping Station on the Kennet and Avon Canal near Bath water powered Cobb s Engine House ruin near southern portal of Netherton Tunnel Crofton Pumping Station on the Kennet and Avon Canal near Great Bedwyn Leawood Pump House on the Cromford Canal in Derbyshire Smethwick Engine now removed from original site to Birmingham Thinktank New Smethwick Pumping Station now part of Galton Valley Canal Heritage Centre Groundwater supply edit Used to pump water from a well into a reservoir Bestwood Pumping Station Nottinghamshire Boughton Pumping Station Nottinghamshire Bratch Pumping Station Staffordshire Mill Meece Pumping Station in Staffordshire Papplewick Pumping Station Nottinghamshire pumped from a 200 ft 61 m deep well Selly Oak Pumping Station Birmingham building converted to an electricity substation Twyford Pumping Station HampshireHydraulic power station edit Wapping Hydraulic Power Station London converted to electricity now an arts centre and restaurant Land drainage edit Pinchbeck Engine near Spalding preserved beam engine and scoop wheel Pode Hole pumping station near Spalding Lincolnshire formerly steam beam engines no longer present Prickwillow Engine House near Ely Cambridgeshire now the Museum of Fenland Drainage Stretham Old Engine Stretham Cambridgeshire Westonzoyland Pumping Station SomersetPublic water supply edit Used to pump drinking water from a reservoir into a water supply system Blagdon Pumping Station Chew Valley Somerset Edgbaston Waterworks Birmingham Kempton Park Pumping Station London Kew Bridge Pumping Station Kew Bridge London Langford Pumping Station Museum of Power Essex Ryhope Engines Museum Sunderland Tees Cottage Pumping Station DarlingtonSewage edit Abbey Pumping Station Leicester Abbey Mills Pumping Station in North London steam engines no longer present Cheddars Lane Pumping Station Cambridge Claymills Pumping Station near Burton upon Trent Coleham Pumping Station Coleham near Shrewsbury Crossness Pumping Station in South London Dock Road Edwardian Pumping Station in Northwich Cheshire Gas engines Built 1913 Low Hall Pumping Station Walthamstow North London Markfield Beam Engine Tottenham London Old Brook Pumping Station Chatham KentUnderground railway edit Brunel Engine House now Brunel Museum Rotherhithe East London extracted water from Thames Tunnel engine no longer present Shore Road Pumping Station Birkenhead Wirral originally steam now electric extracts water from the rail tunnel under the River Mersey Hong Kong edit Public water supplyEngineer s Office of the Former Pumping Station Hong KongIraq edit Agricultural drainageNasiriyah Drainage Pump Station Dhi Qar ProvinceCanada edit Hamilton Museum of Steam and Technology Hamilton Ontario s first Water Works powered by two 1859 steam enginesNetherlands edit Land drainageCruquius pumping station Operational but no longer steam powered an 8 beam Cornish engine with the largest cylinder 144 in 3 5m diameter in the world ir D F Woudagemaal ir Wouda pumping station world s largest steam powered pumping station Spain edit Stations for public water supply in Barcelona One of them is a Barcelona City History Museum heritage site MUHBA Casa de l aigua 5 Another is a museum itself Museu Agbar de les Aigues Agbar water museum 6 United States edit Chicago Avenue Pumping Station in Chicago built in 1869 still in use with modern pumps but also serves as a theater Pumping Station No 2 San Francisco Fire Department Auxiliary Water Supply System San Francisco California listed on the National Register of Historic PlacesSee also editEdmonston Pumping Plant Gatehouse waterworks some gatehouses incorporate pumping stations Submersible pump Water pumping WindpumpWaterworks railways edit Colne Valley Waterworks railway Eastbury Pumping Station near Watford Greater Winnipeg Water District Railway List of narrow gauge railways at water treatment and sewage works in Great Britain Metropolitan Water Board Railway Kempton Park LondonReferences edit In situations such as drilled wells and drinking water Jane Cumberlidge 2009 Inland Waterways of Great Britain 8th Ed Imray Laurie Norie and Wilson p 26 ISBN 978 1 84623 010 3 a b Pumping Station Design Jones Garr M 3rd ed Burlington MA Butterworth Heinemann 2006 p 18 2 ISBN 978 0 08 094106 6 OCLC 144609617 a href Template Cite book html title Template Cite book cite book a CS1 maint others link Design and Construction of Sanitary and Storm Sewers New York American Society of Civil Engineers 1970 p 288 Barcelona City History Museum water pumping station Casa de l Aigua Agbar water museum External links edit nbsp Wikimedia Commons has media related to Pumping stations Packaged pumping stations definitions and applications How To Choose The Right Pump To Suit Your Pumping Station How to look after your packaged pumpstation Prickwillow Museum How Much Do Sewage Pumping Stations Cost Retrieved from https en wikipedia org w index php title Pumping station amp oldid 1212726788, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.