fbpx
Wikipedia

P300 (neuroscience)

The P300 (P3) wave is an event-related potential (ERP) component elicited in the process of decision making. It is considered to be an endogenous potential, as its occurrence links not to the physical attributes of a stimulus, but to a person's reaction to it. More specifically, the P300 is thought to reflect processes involved in stimulus evaluation or categorization.

P300 latency and amplitude trajectories across the lifespan as obtained from the cross-sectional dataset. Dots represent scores from individual participants. From From P300 Development across the Lifespan: A Systematic Review and Meta-Analysis.[1] The latency and amplitude of the P300 response may vary as a function of age.
The P300 response of different healthy subjects in a two-tone auditory oddball paradigm. The plots show the average response to oddball (red) and standard (blue) trials and their difference (black). From Surprise response as a probe for compressed memory states.[2] These examples show the significant individual variability in amplitude, latency and waveform shape across different subjects.

It is usually elicited using the oddball paradigm, in which low-probability target items are mixed with high-probability non-target (or "standard") items. When recorded by electroencephalography (EEG), it surfaces as a positive deflection in voltage with a latency (delay between stimulus and response) of roughly 250 to 500 ms.[3] In the scientific literature a differentiation is often made in the P3, which is divided according to time: Early P3 window (300-400 ms) and Late P3 window (380-440 ms).[4]

The signal is typically measured most strongly by the electrodes covering the parietal lobe. The presence, magnitude, topography and timing of this signal are often used as metrics of cognitive function in decision-making processes. While the neural substrates of this ERP component still remain hazy, the reproducibility and ubiquity of this signal makes it a common choice for psychological tests in both the clinic and laboratory.

History edit

Early observations of the P300 (more specifically, the component that would later be named the P3b) were reported in the mid-1960s. In 1964, researchers Chapman and Bragdon[5] found that ERP responses to visual stimuli differed depending on whether the stimuli had meaning or not. They showed subjects two kinds of visual stimuli: numbers and flashes of light. Subjects viewed these stimuli one at a time in a sequence. For every two numbers, the subjects were required to make simple decisions, such as telling which of the two numbers was numerically smaller or larger, which came first or second in the sequence, or whether they were equal. When examining evoked potentials to these stimuli (i.e., ERPs), Chapman and Bragdon found that both the numbers and the flashes elicited the expected sensory responses (e.g., visual N1 components), and that the amplitude of these responses varied in an expected fashion with the intensity of the stimuli. They also found that the ERP responses to the numbers, but not to the light flashes, contained a large positivity that peaked around 300 ms after the stimulus appeared. Chapman and Bragdon speculated that this differential response to the numbers, which came to be known as the P300 response, resulted from the fact that the numbers were meaningful to the participants, based on the task that they were asked to perform.

In 1965, Sutton and colleagues published results from two experiments that further explored this late positivity. They presented subjects with either a cue that indicated whether the following stimulus would be a click or a flash, or a cue which required subjects to guess whether the following stimulus would be a click or a flash. They found that when subjects were required to guess what the following stimulus would be, the amplitude of the "late positive complex"[6] was larger than when they knew what the stimulus would be. In a second experiment, they presented two cue types. For one cue there was a 2 in 3 chance that the following stimulus would be a click and a 1 in 3 chance that the following stimulus would be a flash. The second cue type had probabilities that were the reverse of the first. They found that the amplitude of the positive complex was larger in response to the less probable stimuli, or the one that only had a 1 in 3 chance of appearing. Another important finding from these studies is that this late positive complex was observed for both the clicks and flashes, indicating that the physical type of the stimulus (auditory or visual) did not matter.

In later studies published in 1967, Sutton and colleagues had subjects guess whether they would hear one click or two clicks.[7] They again observed a positivity around 300 ms after the second click occurred – or would have occurred, in the case of the single click. They also had subjects guess how long the interval between clicks might be, and in this case, the late positivity occurred 300 ms after the second click. This shows two important findings: first, that this late positivity occurred when uncertainty about the type of click was resolved, and second, that even an absence of a stimulus would elicit the late positive complex, if said stimulus was relevant to the task. These early studies encouraged the use of ERP methods to study cognition and provided a foundation for the extensive work on the P300 in the decades that followed.

P3a and P3b edit

 
The P300 response as a function of the oddball probability. From Surprise response as a probe for compressed memory states.[2] The ERP shows a larger P300 response magnitude to oddball stimuli and a lower P300 response to standard stimuli as the oddball probability decreases.

The P3a, or novelty P3,[8] has a positive-going amplitude that displays maximum amplitude over frontal/central electrode sites and has a peak latency in the range of 250–280 ms. The P3a has been associated with brain activity related to the engagement of attention (especially the orienting, involuntary shifts to changes in the environment), and the processing of novelty.[9]

The P3b has a positive-going amplitude (usually relative to a reference behind the ear or the average of two such references) that peaks at around 300 ms, and the peak will vary in latency from 250 to 500 ms or more, depending upon the task and the individual subject response.[3] Amplitudes are typically highest on the scalp over parietal brain areas.[3] The P3b has been a prominent tool used to study cognitive processes, especially psychology research on information processing. Generally speaking, improbable events will elicit a P3b, and the less probable the event, the larger the P3b amplitude.[10] This was shown to be true both for the overall probability and for the local probability.[2] However, in order to elicit a P3b, the improbable event must be related to the task at hand in some way (for example, the improbable event could be an infrequent target letter in a stream of letters, to which a subject might respond with a button press). The P3b can also be used to measure how demanding a task is on cognitive workload.[10]

Since the initial discovery of the P300, research has shown that the P300 has two subcomponents. The subcomponents are the novelty P3, or P3a, and the classic P300, which has since been renamed P3b.[11]

Applications edit

Since the mid-1980s, one of the most discussed uses of ERPs such as the P300 is related to lie detection. In a proposed "guilty knowledge test"[12] a subject is interrogated via the oddball paradigm much as they would be in a typical lie-detector situation. This practice has recently enjoyed increased legal permissibility while conventional polygraphy has seen its use diminish, in part owing to the unconscious and uncontrollable aspects of the P300. The technique relies on reproducible elicitation of the P300 wave, central to the idea of a Memory and Encoding Related Multifaceted Electroencephalographic Response (MERMER) developed by Dr. Lawrence Farwell.

Applications in brain-computer interfacing (BCI) have also been proposed.[13][14][15] The P300 has a number of desirable qualities that aid in implementation of such systems. First, the waveform is consistently detectable and is elicited in response to precise stimuli. The P300 waveform can also be evoked in nearly all subjects with little variation in measurement techniques, which may help simplify interface designs and permit greater usability. The speed at which an interface is able to operate depends on how detectable the signal is despite "noise." One negative characteristic of the P300 is that the amplitude of the waveform requires averaging of multiple recordings to isolate the signal. This and other post-recording processing steps determine the overall speed of an interface.[14] The algorithm proposed by Farwell and Donchin[16] provides an example of a simple BCI that relies on the unconscious decision making processes of the P300 to drive a computer. A 6×6 grid of characters is presented to the subject, and various columns or rows are highlighted. When a column or row contains the character a subject desires to communicate, the P300 response is elicited (since this character is "special" it is the target stimulus described in the typical oddball paradigm). The combination of the row and column which evoked the response locates the desired character. A number of such trials must be averaged to clear noise from the EEG. The speed of the highlighting determines the number of characters processed per minute. Results from studies using this setup show that normal subjects could achieve a 95% success rate at 3.4–4.3 chars/min. Such success rates are not limited to non-disabled users; a study conducted in 2000 revealed that 4 paralyzed participants (one with complete paraplegia, three with incomplete paraplegia) performed as successfully as 10 normal participants.[14]

Scientific research often relies on measurement of the P300 to examine event related potentials, especially with regard to decision making. Because cognitive impairment is often correlated with modifications in the P300, the waveform can be used as a measure for the efficacy of various treatments on cognitive function. Some have suggested its use as a clinical marker for precisely these reasons. There is a broad range of uses for the P300 in clinical research.[17]

Some research groups have performed fMRI combined to EEG in order to achieve inner-speech dictation and the approach of inner-speech recognition.[18][19][20]

The P300 wave obtained by visual stimulation is used to assess cognitive processes in humans, and the value of the latency and amplitude of the P300 wave can be a measure of the severity of dementia processes. [21] The analysis of P300 wave latency seems to be particularly useful in the diagnosis of mild cognitive impairment (MCI). [22]

See also edit

References edit

  1. ^ Rik van Dinteren; Martijn Arns; Marijtje L. A. Jongsma; Roy P. C. Kessels (2014). "P300 Development across the Lifespan: A Systematic Review and Meta-Analysis". PLOS ONE. 9 (2): e87347. doi:10.1371/journal.pone.0087347. PMC 3923761. PMID 24551055.
  2. ^ a b c Levi-Aharoni, Hadar; Shriki, Oren; Tishby, Naftali (2020-02-03). "Surprise response as a probe for compressed memory states". PLOS Computational Biology. 16 (2): e1007065. doi:10.1371/journal.pcbi.1007065. ISSN 1553-7358. PMC 7018098. PMID 32012146.
  3. ^ a b c Polich, J. (2007). "Updating P300: An integrative theory of P3a and P3b". Clinical Neurophysiology. 118 (10): 2128–2148. doi:10.1016/j.clinph.2007.04.019. PMC 2715154. PMID 17573239.
  4. ^ Keil, A.; Bradley, M. M.; Hauk, O.; Rockstroh, B.; Elbert, T. & Lang, P. J. (2002). "Large-scale neural correlates of affective picture processing". Psychophysiology. 39 (5): 641–649. doi:10.1017/S0048577202394162. PMID 12236331.
  5. ^ Chapman, R.M. & Bragdon, H.R. (1964). "Evoked responses to numerical and non-numerical visual stimuli while problem solving". Nature. 203 (4950): 1155–1157. Bibcode:1964Natur.203.1155C. doi:10.1038/2031155a0. PMID 14213667. S2CID 4156804.
  6. ^ Sutton, S.; Braren, M.; Zubin, J. & John, E.R. (1965). "Evoked-Potential Correlates of Stimulus Uncertainty". Science. 150 (3700): 1187–1188. Bibcode:1965Sci...150.1187S. doi:10.1126/science.150.3700.1187. PMID 5852977. S2CID 39822117.
  7. ^ Sutton, S.; Tueting, P.; Zubin, J. & John, E.R. (1967). "Information delivery and the sensory evoked potential". Science. 155 (3768): 1436–1439. Bibcode:1967Sci...155.1436S. doi:10.1126/science.155.3768.1436. PMID 6018511. S2CID 36787865.
  8. ^ Comerchero, M. D.; Polich, J. (1999). "P3a and P3b from typical auditory and visual stimuli" (PDF). Clinical Neurophysiology. 110 (1): 24–30. CiteSeerX 10.1.1.576.880. doi:10.1016/S0168-5597(98)00033-1. PMID 10348317. S2CID 17357823.
  9. ^ Polich, J. (2003). "Overview of P3a and P3b". In J. Polich (ed.). Detection of Change: Event-Related Potential and fMRI Findings. Boston: Kluwer Academic Press. pp. 83–98.
  10. ^ a b Donchin, E. (1981). "Presidential Address, 1980: Surprise!...Surprise?" (PDF). Psychophysiology. 18 (5): 493–513. doi:10.1111/j.1469-8986.1981.tb01815.x. PMID 7280146.
  11. ^ Squires, N. K.; Squires, K. C. & Hillyard, S. A. (1975). "Two varieties of long-latency positive waves evoked by unpredictable auditory stimuli in man". Electroencephalography and Clinical Neurophysiology. 38 (4): 387–401. CiteSeerX 10.1.1.326.332. doi:10.1016/0013-4694(75)90263-1. PMID 46819. S2CID 4614708.
  12. ^ Farwell LA, Smith SS (January 2001). (PDF). J Forensic Sci. 46 (1): 135–143. doi:10.1520/JFS14925J. PMID 11210899. Archived from the original (PDF) on 2016-03-17. Retrieved 2016-07-22.
  13. ^ Piccione F, Giorgi F, Tonin P, et al. (March 2006). "P300-based brain computer interface: Reliability and performance in healthy and paralysed participants". Clin Neurophysiol. 117 (3): 531–537. doi:10.1016/j.clinph.2005.07.024. PMID 16458069. S2CID 24199528.
  14. ^ a b c Donchin E, Spencer KM, Wijesinghe R (June 2000). "The Mental Prosthesis: Assessing the Speed of a P300-Based Brain–Computer Interface". IEEE Transactions on Rehabilitation Engineering. 8 (2): 174–179. CiteSeerX 10.1.1.133.8980. doi:10.1109/86.847808. PMID 10896179. S2CID 84043.
  15. ^ Nijboer F, Sellers EW, Mellinger J, et al. (2008). "A P300-based brain–computer interface for people with amyotrophic lateral sclerosis". Clin Neurophysiol. 119 (8): 1909–1916. doi:10.1016/j.clinph.2008.03.034. PMC 2853977. PMID 18571984.
  16. ^ L. A. Farwell & E. Donchin (1988). (PDF). Electroencephalogr. Clin. Neurophysiol. 70 (6): 510–523. doi:10.1016/0013-4694(88)90149-6. PMID 2461285. S2CID 4547500. Archived from the original (PDF) on 2017-02-05.
  17. ^ Hansenne M (August 2000). "Le potentiel évoqué cognitif P300 (II) : variabilité interindividuelle et application clinique en psychopathologie" [The P300 event-related potential. II. Interindividual variability and clinical application in psychopathology]. Clin Neurophysiol (in French). 30 (4): 211–231. doi:10.1016/S0987-7053(00)00224-0. PMID 11013895. S2CID 53176706.
  18. ^ Bledowski, Christoph; Prvulovic, David; Hoechstetter, Karsten; Scherg, Michael; Wibral, Michael; Goebel, Rainer; Linden, David E. J. (2004-10-20). "Localizing P300 Generators in Visual Target and Distractor Processing: A Combined Event-Related Potential and Functional Magnetic Resonance Imaging Study". The Journal of Neuroscience. 24 (42): 9353–9360. doi:10.1523/jneurosci.1897-04.2004. ISSN 0270-6474. PMC 6730097. PMID 15496671.
  19. ^ Nieto, Nicolás; Peterson, Victoria; Rufiner, Hugo Leonardo; Kamienkoski, Juan; Spies, Ruben (2021-04-20). ""Thinking out loud": an open-access EEG-based BCI dataset for inner speech recognition". doi:10.1101/2021.04.19.440473. S2CID 233414714. Retrieved 2023-04-20. {{cite journal}}: Cite journal requires |journal= (help)
  20. ^ Liwicki, Foteini Simistira; Gupta, Vibha; Saini, Rajkumar; De, Kanjar; Abid, Nosheen; Rakesh, Sumit; Wellington, Scott; Wilson, Holly; Liwicki, Marcus; Eriksson, Johan (2022-11-30). "Bimodal electroencephalography-functional magnetic resonance imaging dataset for inner-speech recognition": 2022.05.24.492109. doi:10.1101/2022.05.24.492109. S2CID 254126820. {{cite journal}}: Cite journal requires |journal= (help)
  21. ^ Derkowski, Wojciech; Kędzia, Alicja; Derkowski, Piotr (2016). "THE CLINICAL SIGNIFICANCE OF P300 WAVE IN THE STUDY OF COMPUTER-AVERAGE COGNITIVE EVOKED POTENTIALS". Computer-aided scientific research: 11–17. doi:10.5281/zenodo.10614201.
  22. ^ Derkowski, Wojciech; Derkowski, Piotr (April 2018). "Signification clinique de l'onde P300 pour le diagnostic et l'évaluation du traitement de la maladie d'Alzheimer et de trouble cognitif léger". Revue Neurologique. 174 (Elsevier Masson): S12–S13. doi:10.1016/j.neurol.2018.01.027.

External links edit

p300, neuroscience, p300, wave, event, related, potential, component, elicited, process, decision, making, considered, endogenous, potential, occurrence, links, physical, attributes, stimulus, person, reaction, more, specifically, p300, thought, reflect, proce. The P300 P3 wave is an event related potential ERP component elicited in the process of decision making It is considered to be an endogenous potential as its occurrence links not to the physical attributes of a stimulus but to a person s reaction to it More specifically the P300 is thought to reflect processes involved in stimulus evaluation or categorization P300 latency and amplitude trajectories across the lifespan as obtained from the cross sectional dataset Dots represent scores from individual participants From From P300 Development across the Lifespan A Systematic Review and Meta Analysis 1 The latency and amplitude of the P300 response may vary as a function of age The P300 response of different healthy subjects in a two tone auditory oddball paradigm The plots show the average response to oddball red and standard blue trials and their difference black From Surprise response as a probe for compressed memory states 2 These examples show the significant individual variability in amplitude latency and waveform shape across different subjects It is usually elicited using the oddball paradigm in which low probability target items are mixed with high probability non target or standard items When recorded by electroencephalography EEG it surfaces as a positive deflection in voltage with a latency delay between stimulus and response of roughly 250 to 500 ms 3 In the scientific literature a differentiation is often made in the P3 which is divided according to time Early P3 window 300 400 ms and Late P3 window 380 440 ms 4 The signal is typically measured most strongly by the electrodes covering the parietal lobe The presence magnitude topography and timing of this signal are often used as metrics of cognitive function in decision making processes While the neural substrates of this ERP component still remain hazy the reproducibility and ubiquity of this signal makes it a common choice for psychological tests in both the clinic and laboratory Contents 1 History 2 P3a and P3b 3 Applications 4 See also 5 References 6 External linksHistory editEarly observations of the P300 more specifically the component that would later be named the P3b were reported in the mid 1960s In 1964 researchers Chapman and Bragdon 5 found that ERP responses to visual stimuli differed depending on whether the stimuli had meaning or not They showed subjects two kinds of visual stimuli numbers and flashes of light Subjects viewed these stimuli one at a time in a sequence For every two numbers the subjects were required to make simple decisions such as telling which of the two numbers was numerically smaller or larger which came first or second in the sequence or whether they were equal When examining evoked potentials to these stimuli i e ERPs Chapman and Bragdon found that both the numbers and the flashes elicited the expected sensory responses e g visual N1 components and that the amplitude of these responses varied in an expected fashion with the intensity of the stimuli They also found that the ERP responses to the numbers but not to the light flashes contained a large positivity that peaked around 300 ms after the stimulus appeared Chapman and Bragdon speculated that this differential response to the numbers which came to be known as the P300 response resulted from the fact that the numbers were meaningful to the participants based on the task that they were asked to perform In 1965 Sutton and colleagues published results from two experiments that further explored this late positivity They presented subjects with either a cue that indicated whether the following stimulus would be a click or a flash or a cue which required subjects to guess whether the following stimulus would be a click or a flash They found that when subjects were required to guess what the following stimulus would be the amplitude of the late positive complex 6 was larger than when they knew what the stimulus would be In a second experiment they presented two cue types For one cue there was a 2 in 3 chance that the following stimulus would be a click and a 1 in 3 chance that the following stimulus would be a flash The second cue type had probabilities that were the reverse of the first They found that the amplitude of the positive complex was larger in response to the less probable stimuli or the one that only had a 1 in 3 chance of appearing Another important finding from these studies is that this late positive complex was observed for both the clicks and flashes indicating that the physical type of the stimulus auditory or visual did not matter In later studies published in 1967 Sutton and colleagues had subjects guess whether they would hear one click or two clicks 7 They again observed a positivity around 300 ms after the second click occurred or would have occurred in the case of the single click They also had subjects guess how long the interval between clicks might be and in this case the late positivity occurred 300 ms after the second click This shows two important findings first that this late positivity occurred when uncertainty about the type of click was resolved and second that even an absence of a stimulus would elicit the late positive complex if said stimulus was relevant to the task These early studies encouraged the use of ERP methods to study cognition and provided a foundation for the extensive work on the P300 in the decades that followed P3a and P3b editMain articles P3a and P3b nbsp The P300 response as a function of the oddball probability From Surprise response as a probe for compressed memory states 2 The ERP shows a larger P300 response magnitude to oddball stimuli and a lower P300 response to standard stimuli as the oddball probability decreases The P3a or novelty P3 8 has a positive going amplitude that displays maximum amplitude over frontal central electrode sites and has a peak latency in the range of 250 280 ms The P3a has been associated with brain activity related to the engagement of attention especially the orienting involuntary shifts to changes in the environment and the processing of novelty 9 The P3b has a positive going amplitude usually relative to a reference behind the ear or the average of two such references that peaks at around 300 ms and the peak will vary in latency from 250 to 500 ms or more depending upon the task and the individual subject response 3 Amplitudes are typically highest on the scalp over parietal brain areas 3 The P3b has been a prominent tool used to study cognitive processes especially psychology research on information processing Generally speaking improbable events will elicit a P3b and the less probable the event the larger the P3b amplitude 10 This was shown to be true both for the overall probability and for the local probability 2 However in order to elicit a P3b the improbable event must be related to the task at hand in some way for example the improbable event could be an infrequent target letter in a stream of letters to which a subject might respond with a button press The P3b can also be used to measure how demanding a task is on cognitive workload 10 Since the initial discovery of the P300 research has shown that the P300 has two subcomponents The subcomponents are the novelty P3 or P3a and the classic P300 which has since been renamed P3b 11 Applications editSince the mid 1980s one of the most discussed uses of ERPs such as the P300 is related to lie detection In a proposed guilty knowledge test 12 a subject is interrogated via the oddball paradigm much as they would be in a typical lie detector situation This practice has recently enjoyed increased legal permissibility while conventional polygraphy has seen its use diminish in part owing to the unconscious and uncontrollable aspects of the P300 The technique relies on reproducible elicitation of the P300 wave central to the idea of a Memory and Encoding Related Multifaceted Electroencephalographic Response MERMER developed by Dr Lawrence Farwell Applications in brain computer interfacing BCI have also been proposed 13 14 15 The P300 has a number of desirable qualities that aid in implementation of such systems First the waveform is consistently detectable and is elicited in response to precise stimuli The P300 waveform can also be evoked in nearly all subjects with little variation in measurement techniques which may help simplify interface designs and permit greater usability The speed at which an interface is able to operate depends on how detectable the signal is despite noise One negative characteristic of the P300 is that the amplitude of the waveform requires averaging of multiple recordings to isolate the signal This and other post recording processing steps determine the overall speed of an interface 14 The algorithm proposed by Farwell and Donchin 16 provides an example of a simple BCI that relies on the unconscious decision making processes of the P300 to drive a computer A 6 6 grid of characters is presented to the subject and various columns or rows are highlighted When a column or row contains the character a subject desires to communicate the P300 response is elicited since this character is special it is the target stimulus described in the typical oddball paradigm The combination of the row and column which evoked the response locates the desired character A number of such trials must be averaged to clear noise from the EEG The speed of the highlighting determines the number of characters processed per minute Results from studies using this setup show that normal subjects could achieve a 95 success rate at 3 4 4 3 chars min Such success rates are not limited to non disabled users a study conducted in 2000 revealed that 4 paralyzed participants one with complete paraplegia three with incomplete paraplegia performed as successfully as 10 normal participants 14 Scientific research often relies on measurement of the P300 to examine event related potentials especially with regard to decision making Because cognitive impairment is often correlated with modifications in the P300 the waveform can be used as a measure for the efficacy of various treatments on cognitive function Some have suggested its use as a clinical marker for precisely these reasons There is a broad range of uses for the P300 in clinical research 17 Some research groups have performed fMRI combined to EEG in order to achieve inner speech dictation and the approach of inner speech recognition 18 19 20 The P300 wave obtained by visual stimulation is used to assess cognitive processes in humans and the value of the latency and amplitude of the P300 wave can be a measure of the severity of dementia processes 21 The analysis of P300 wave latency seems to be particularly useful in the diagnosis of mild cognitive impairment MCI 22 See also editError related negativity Lateralized readiness potentialReferences edit Rik van Dinteren Martijn Arns Marijtje L A Jongsma Roy P C Kessels 2014 P300 Development across the Lifespan A Systematic Review and Meta Analysis PLOS ONE 9 2 e87347 doi 10 1371 journal pone 0087347 PMC 3923761 PMID 24551055 a b c Levi Aharoni Hadar Shriki Oren Tishby Naftali 2020 02 03 Surprise response as a probe for compressed memory states PLOS Computational Biology 16 2 e1007065 doi 10 1371 journal pcbi 1007065 ISSN 1553 7358 PMC 7018098 PMID 32012146 a b c Polich J 2007 Updating P300 An integrative theory of P3a and P3b Clinical Neurophysiology 118 10 2128 2148 doi 10 1016 j clinph 2007 04 019 PMC 2715154 PMID 17573239 Keil A Bradley M M Hauk O Rockstroh B Elbert T amp Lang P J 2002 Large scale neural correlates of affective picture processing Psychophysiology 39 5 641 649 doi 10 1017 S0048577202394162 PMID 12236331 Chapman R M amp Bragdon H R 1964 Evoked responses to numerical and non numerical visual stimuli while problem solving Nature 203 4950 1155 1157 Bibcode 1964Natur 203 1155C doi 10 1038 2031155a0 PMID 14213667 S2CID 4156804 Sutton S Braren M Zubin J amp John E R 1965 Evoked Potential Correlates of Stimulus Uncertainty Science 150 3700 1187 1188 Bibcode 1965Sci 150 1187S doi 10 1126 science 150 3700 1187 PMID 5852977 S2CID 39822117 Sutton S Tueting P Zubin J amp John E R 1967 Information delivery and the sensory evoked potential Science 155 3768 1436 1439 Bibcode 1967Sci 155 1436S doi 10 1126 science 155 3768 1436 PMID 6018511 S2CID 36787865 Comerchero M D Polich J 1999 P3a and P3b from typical auditory and visual stimuli PDF Clinical Neurophysiology 110 1 24 30 CiteSeerX 10 1 1 576 880 doi 10 1016 S0168 5597 98 00033 1 PMID 10348317 S2CID 17357823 Polich J 2003 Overview of P3a and P3b In J Polich ed Detection of Change Event Related Potential and fMRI Findings Boston Kluwer Academic Press pp 83 98 a b Donchin E 1981 Presidential Address 1980 Surprise Surprise PDF Psychophysiology 18 5 493 513 doi 10 1111 j 1469 8986 1981 tb01815 x PMID 7280146 Squires N K Squires K C amp Hillyard S A 1975 Two varieties of long latency positive waves evoked by unpredictable auditory stimuli in man Electroencephalography and Clinical Neurophysiology 38 4 387 401 CiteSeerX 10 1 1 326 332 doi 10 1016 0013 4694 75 90263 1 PMID 46819 S2CID 4614708 Farwell LA Smith SS January 2001 Using brain MERMER testing to detect knowledge despite efforts to conceal PDF J Forensic Sci 46 1 135 143 doi 10 1520 JFS14925J PMID 11210899 Archived from the original PDF on 2016 03 17 Retrieved 2016 07 22 Piccione F Giorgi F Tonin P et al March 2006 P300 based brain computer interface Reliability and performance in healthy and paralysed participants Clin Neurophysiol 117 3 531 537 doi 10 1016 j clinph 2005 07 024 PMID 16458069 S2CID 24199528 a b c Donchin E Spencer KM Wijesinghe R June 2000 The Mental Prosthesis Assessing the Speed of a P300 Based Brain Computer Interface IEEE Transactions on Rehabilitation Engineering 8 2 174 179 CiteSeerX 10 1 1 133 8980 doi 10 1109 86 847808 PMID 10896179 S2CID 84043 Nijboer F Sellers EW Mellinger J et al 2008 A P300 based brain computer interface for people with amyotrophic lateral sclerosis Clin Neurophysiol 119 8 1909 1916 doi 10 1016 j clinph 2008 03 034 PMC 2853977 PMID 18571984 L A Farwell amp E Donchin 1988 Talking off the top of your head A mental prosthesis utilizing event related brain potentials PDF Electroencephalogr Clin Neurophysiol 70 6 510 523 doi 10 1016 0013 4694 88 90149 6 PMID 2461285 S2CID 4547500 Archived from the original PDF on 2017 02 05 Hansenne M August 2000 Le potentiel evoque cognitif P300 II variabilite interindividuelle et application clinique en psychopathologie The P300 event related potential II Interindividual variability and clinical application in psychopathology Clin Neurophysiol in French 30 4 211 231 doi 10 1016 S0987 7053 00 00224 0 PMID 11013895 S2CID 53176706 Bledowski Christoph Prvulovic David Hoechstetter Karsten Scherg Michael Wibral Michael Goebel Rainer Linden David E J 2004 10 20 Localizing P300 Generators in Visual Target and Distractor Processing A Combined Event Related Potential and Functional Magnetic Resonance Imaging Study The Journal of Neuroscience 24 42 9353 9360 doi 10 1523 jneurosci 1897 04 2004 ISSN 0270 6474 PMC 6730097 PMID 15496671 Nieto Nicolas Peterson Victoria Rufiner Hugo Leonardo Kamienkoski Juan Spies Ruben 2021 04 20 Thinking out loud an open access EEG based BCI dataset for inner speech recognition doi 10 1101 2021 04 19 440473 S2CID 233414714 Retrieved 2023 04 20 a href Template Cite journal html title Template Cite journal cite journal a Cite journal requires journal help Liwicki Foteini Simistira Gupta Vibha Saini Rajkumar De Kanjar Abid Nosheen Rakesh Sumit Wellington Scott Wilson Holly Liwicki Marcus Eriksson Johan 2022 11 30 Bimodal electroencephalography functional magnetic resonance imaging dataset for inner speech recognition 2022 05 24 492109 doi 10 1101 2022 05 24 492109 S2CID 254126820 a href Template Cite journal html title Template Cite journal cite journal a Cite journal requires journal help Derkowski Wojciech Kedzia Alicja Derkowski Piotr 2016 THE CLINICAL SIGNIFICANCE OF P300 WAVE IN THE STUDY OF COMPUTER AVERAGE COGNITIVE EVOKED POTENTIALS Computer aided scientific research 11 17 doi 10 5281 zenodo 10614201 Derkowski Wojciech Derkowski Piotr April 2018 Signification clinique de l onde P300 pour le diagnostic et l evaluation du traitement de la maladie d Alzheimer et de trouble cognitif leger Revue Neurologique 174 Elsevier Masson S12 S13 doi 10 1016 j neurol 2018 01 027 External links editP300 Event Related Potentials at the U S National Library of Medicine Medical Subject Headings MeSH Retrieved from https en wikipedia org w index php title P300 neuroscience amp oldid 1203449623, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.