Live-cell imaging is the study of living cells using time-lapse microscopy. It is used by scientists to obtain a better understanding of biological function through the study of cellular dynamics.[1] Live-cell imaging was pioneered in the first decade of the 21st century. One of the first time-lapse microcinematographic films of cells ever made was made by Julius Ries, showing the fertilization and development of the sea urchin egg.[2] Since then, several microscopy methods have been developed to study living cells in greater detail with less effort. A newer type of imaging using quantum dots have been used, as they are shown to be more stable.[3] The development of holotomographic microscopy has disregarded phototoxicity and other staining-derived disadvantages by implementing digital staining based on cells’ refractive index.[4][5]

A live-cell microscope. Live-cell microscopes are generally inverted. To keep cells alive during observation, the microscopes are commonly enclosed in a micro cell incubator (the transparent box).

Overview edit

Biological systems exist as a complex interplay of countless cellular components interacting across four dimensions to produce the phenomenon called life. While it is common to reduce living organisms to non-living samples to accommodate traditional static imaging tools, the further the sample deviates from the native conditions, the more likely the delicate processes in question will exhibit perturbations.[6] The onerous task of capturing the true physiological identity of living tissue, therefore, requires high-resolution visualization across both space and time within the parent organism.[7] The technological advances of live-cell imaging, designed to provide spatiotemporal images of subcellular events in real time, serves an important role for corroborating the biological relevance of physiological changes observed during experimentation. Due to their contiguous relationship with physiological conditions, live-cell assays are considered the standard for probing complex and dynamic cellular events.[8] As dynamic processes such as migration, cell development, and intracellular trafficking increasingly become the focus of biological research, techniques capable of capturing 3-dimensional data in real time for cellular networks (in situ) and entire organisms (in vivo) will become indispensable tools in understanding biological systems. The general acceptance of live-cell imaging has led to a rapid expansion in the number of practitioners and established a need for increased spatial and temporal resolution without compromising the health of the cell.[9]

Types of microscopy used edit

Phase contrast edit

Phase contrast microscopy time-lapse video of dividing rattle grasshopper spermatocytes. This historic film, which popularized phase contrast microscopy, was made in the early 1940s by Kurt Michel of the Carl Zeiss company.[10]

Before the introduction of the phase-contrast microscope, it was difficult to observe living cells. As living cells are translucent, they must be stained to be visible in a traditional light microscope. Unfortunately, the process of staining cells generally kills them. With the invention of the phase-contrast microscopy it became possible to observe unstained living cells in detail. After its introduction in the 1940s, live-cell imaging rapidly became popular using phase-contrast microscopy.[11] The phase-contrast microscope was popularized through a series of time-lapse movies (see video), recorded using a photographic film camera.[12] Its inventor, Frits Zernike, was awarded the Nobel Prize in 1953.[13] Other later phase-contrast techniques used to observe unstained cells are Hoffman modulation and differential interference contrast microscopy.

Fluorescent edit

Fluorescent microscopy time-lapse video of a dividing purple sea urchin embryo.[14]

Phase-contrast microscopy does not have the capacity to observe specific proteins or other organic chemical compounds which form the complex machinery of a cell. Synthetic and organic fluorescent stains have therefore been developed to label such compounds, making them observable by fluorescent microscopy (see video).[15] Fluorescent stains are, however, phototoxic, invasive and bleach when observed. This limits their use when observing living cells over extended periods of time. Non-invasive phase-contrast techniques are therefore often used as a vital complement to fluorescent microscopy in live-cell imaging applications.[16][17] Deep learning-assisted fluorescence microscopy methods, however, help to reduced light burden and phototoxicity and allow even repeated high resolution live imaging.[18]

Quantitative phase contrast edit

Quantitative phase contrast microscopy video of a dividing breast cancer cells.[19]

As a result of the rapid increase in pixel density of digital image sensors, quantitative phase-contrast microscopy has emerged as an alternative microscopy method for live-cell imaging.[20][21] Quantitative phase-contrast microscopy has an advantage over fluorescent and phase-contrast microscopy in that it is both non-invasive and quantitative in its nature.

Due to the narrow focal depth of conventional microscopy, live-cell imaging is to a large extent currently limited to observing cells on a single plane. Most implementations of quantitative phase-contrast microscopy allow creating and focusing images at different focal planes from a single exposure. This opens up the future possibility of 3-dimensional live-cell imaging by means of fluorescence techniques.[22] Quantitative phase-contrast microscopy with rotational scanning allow 3D time-lapse images of living cells to be acquired at high resolution.[23][24][4]

Holotomography edit

Holotomography (HT) is a laser technique to measure three-dimensional refractive index (RI) tomogram of a microscopic sample such as biological cells and tissues. Because the RI can serve as an intrinsic imaging contrast for transparent or phase objects, measurements of RI tomograms can provide label-free quantitative imaging of microscopic phase objects. In order to measure 3D RI tomogram of samples, HT employs the principle of holographic imaging and inverse scattering. Typically, multiple 2D holographic images of a sample are measured at various illumination angles, employing the principle of interferometric imaging. Then, a 3D RI tomogram of the sample is reconstructed from these multiple 2D holographic images by inversely solving light scattering in the sample.

The principle of HT is very similar to X-ray computed tomography (CT), or CT scan. CT scan measures multiple 2D X-ray images of a human body at various illumination angles, and a 3D tomogram (X-ray absorptivity) is then retrieved using the inverse scattering theory. Both the X-ray CT and laser HT shares the same governing equation – Helmholtz equation, the wave equation for a monochromatic wavelength. HT is also known as optical diffraction tomography.

The combination of holography and rotational scanning allows long-term, label-free, live-cell recordings.

Non-invasive optical nanoscopy can achieve such a lateral resolution by using a quasi--holographic detection scheme and complex deconvolution. The spatial frequencies of the imaged cell do not make any sense to the human eye. But these scattered frequencies are converted into a hologram and synthesize a bandpass, which has a resolution double the one normally available. Holograms are recorded from different illumination directions on the sample plane and observe sub-wavelength tomographic variations of the specimen. Nanoscale apertures serve to calibrate the tomographic reconstruction and to characterize the imaging system by means of the coherent transfer function. This gives rise to realistic inverse filtering and guarantees true complex field reconstruction.[24]

In conclusion, the 2 terminologies of (i) optical resolution (the real one) and (ii) sampling resolution (the one on the screen) are separated for 3D holotomographic microscopy.

Instrumentation and optics edit

Live-cell imaging represents a careful compromise between acquiring the highest-resolution image and keeping the cells alive for as long as possible.[25] As a result, live-cell microscopists face a unique set of challenges that are often overlooked when working with fixed specimens. Moreover, live-cell imaging often employs special optical system and detector specifications. For example, ideally the microscopes used in live-cell imaging would have high signal-to-noise ratios, fast image acquisition rates to capture time-lapse video of extracellular events, and maintaining the long-term viability of the cells.[26] However, optimizing even a single facet of image acquisition can be resource-intensive and should be considered on a case-by-case basis.

Lens designs edit

 
A) Upright lens configuration. B) Inverted lens configuration.

Low-magnification "dry" edit

In cases where extra space between the objective and the specimen is required to work with the sample, a dry lens can be used, potentially requiring additional adjustments of the correction collar, which changes the location of the lens in the objective, to account for differences in imaging chambers. Special objective lenses are designed with correction collars that correct for spherical aberrations while accounting for the cover-slip thickness. In high-numerical-aperture (NA) dry objective lenses, the correction collar adjustment ring changes the position of a movable lens group to account for differences in the way the outside of the lens focuses light relative to the center. Although lens aberrations are inherent in all lens designs, they become more problematic in dry lenses, where resolution retention is key.[27]

Oil-immersion high-NA edit

Oil immersion is a technique that can increase image resolution by immersing the lens and the specimen in oil with a high refractive index. Since light bends when it passes between media with different refractive indexes, by placing oil with the same refractive index as glass between the lens and the slide, two transitions between refractive indices can be avoided.[28] However, for most applications it is recommended that oil immersion be used with fixed (dead) specimens because live cells require an aqueous environment, and the mixing of oil and water can cause severe spherical aberrations. For some applications silicone oil can be used to produce more accurate image reconstructions. Silicone oil is an attractive medium because it has a refractive index that is close to that of living cells, allowing to produce high-resolution images while minimizing spherical aberrations.[27]

Water-immersion edit

Live-cell imaging requires a sample in an aqueous environment that is often 50 to 200 micrometers away from the cover glass. Therefore, water-immersion lenses can help achieve a higher resolving power due to the fact that both the environment and the cells themselves will be close to the refractive index of water. Water-immersion lenses are designed to be compatible with the refractive index of water and usually have a corrective collar that allows adjustment of the objective. Additionally, because of the higher refractive index of water, water-immersion lenses have a high numerical aperture and can produce images superior to oil-immersion lens when resolving planes deeper than 0 µm.[27]

Dipping edit

Another solution for live-cell imaging is the dipping lens. These lenses are a subset of water-immersion lenses that do not require a cover slip and can be dipped directly into the aqueous environment of the sample. One of the main advantages of the dipping lens is that it has a long effective working distance.[29] Since a cover slip is not required, this type of lens can approach the surface of the specimen, and as a result, the resolution is limited by the restraints imposed by spherical aberration rather than the physical limitations of the cover slip. Although dipping lenses can be very useful, they are not ideal for all experiments, since the act of "dipping" the lens can disturb the cells in the sample. Additionally, since the incubation chamber must be open to the lens, changes in the sample environment due to evaporation must be closely monitored.[27]

Phototoxicity and photobleaching edit

Today, most live imaging techniques rely on either high-illumination regimes or fluorescent labelling, both inducing phototoxicity and compromising the ability to keep cells unperturbed and alive over time. Since our knowledge of biology is driven by observation, it is key to minimize the perturbations induced by the imaging technique.

The rise of confocal microscopy is closely correlated with accessibility of high-power lasers, which are able to achieve high intensities of light excitation. However, the high-power output can damage sensitive fluorophores, so the lasers usually run significantly below their full power output.[30] Overexposure to light can result in photodamage due to photobleaching or phototoxicity. The effects of photobleaching can significantly reduce the quality of fluorescent images, and in recent years there has been a significant demand for longer-lasting commercial fluorophores. One solution, the Alexa Fluor series, show little to no fading even at high laser intensities.[31]

Under physiological conditions, many cells and tissue types are exposed to only low levels of light.[32] As a result, it is important to minimize the exposure of live cells to high doses of ultraviolet (UV), infrared (IR), or fluorescence exciting wavelengths of light, which can damage DNA, raise cellular temperatures, and cause photobleaching respectively.[33] High-energy photons absorbed by the fluorophores and the sample are emitted at longer wavelengths proportional to the Stokes shift.[34] However, cellular organelles can be damaged when the photon energy produces chemical and molecular changes rather than being re-emitted.[35] It is believed that the primary culprit in the light-induced toxicity experienced by live cells is a result of free radicals produced by the excitation of fluorescent molecules.[32] These free radicals are highly reactive and cause the destruction of cellular components, which can result in non-physiological behavior.

One method of minimizing photo-damage is to lower the oxygen concentration in the sample to avoid the formation of reactive oxygen species.[36] However, this method is not always possible in live-cell imaging and may require additional intervention. Another method for reducing the effects of free radicals in the sample is the use of antifade reagents. Unfortunately, most commercial antifade reagents cannot be used in live-cell imaging because of their toxicity.[37] Instead, natural free-radical scavengers such as vitamin C or vitamin E can be used without substantially altering physiological behavior on shorter time scales.[38] Phototoxicity-free live-cell imaging has recently been developed and commercialised. Holotomographic microscopy avoids phototoxicity thanks to its low-power laser (laser class 1: 0.2 mW/mm2).[4][5][39]

See also edit

References edit

  1. ^ Baker M (August 2010). "Cellular imaging: Taking a long, hard look". Nature. 466 (7310): 1137–1140. Bibcode:2010Natur.466.1137B. doi:10.1038/4661137a. PMID 20740018. S2CID 205056946.
  2. ^ Landecker H (October 2009). "Seeing things: from microcinematography to live cell imaging". Nature Methods. 6 (10): 707–709. doi:10.1038/nmeth1009-707. PMID 19953685. S2CID 6521488.
  3. ^ Jaiswal JK, Goldman ER, Mattoussi H, Simon SM (October 2004). "Use of quantum dots for live cell imaging". Nature Methods. 1 (1): 73–78. doi:10.1038/nmeth1004-73. PMID 16138413. S2CID 13339279.
  4. ^ a b c Pollaro, L.; Equis, S.; Dalla Piazza, B.; Cotte, Y. (2016). "Stain-free 3D Nanoscopy of Living Cells". Optik & Photonik. 11: 38–42. doi:10.1002/opph.201600008.
  5. ^ a b Pollaro, L.; Dalla Piazza, B.; Cotte, Y. (2015). "Digital Staining: Microscopy of Live Cells Without Invasive Chemicals" (PDF). Microscopy Today. 23 (4): 12–17. doi:10.1017/S1551929515000590. S2CID 135982205.
  6. ^ Petroll, W. M.; Jester, J. V.; Cavanagh, H. D. (May 1994). "In vivo confocal imaging: general principles and applications". Scanning. 16 (3): 131–149. ISSN 0161-0457. PMID 8038913.
  7. ^ Meijering, Erik; Dzyubachyk, Oleh; Smal, Ihor (2012-01-01). "Methods for Cell and Particle Tracking". . Methods in Enzymology. Vol. 504. pp. 183–200. doi:10.1016/B978-0-12-391857-4.00009-4. ISBN 9780123918574. ISSN 0076-6879. PMID 22264535. Archived from the original on 2022-05-05. Retrieved 2019-12-02.
  8. ^ Allan, Victoria J.; Stephens, David J. (2003-04-04). "Light Microscopy Techniques for Live Cell Imaging". Science. 300 (5616): 82–86. Bibcode:2003Sci...300...82S. CiteSeerX 10.1.1.702.4732. doi:10.1126/science.1082160. ISSN 1095-9203. PMID 12677057. S2CID 33199613.
  9. ^ Dance, Amber (2018-03-27). "Live-cell imaging: Deeper, faster, wider". Science. AAAS. Retrieved 2018-12-17.
  10. ^ Michel K. "Historic time lapse movie by Dr. Kurt Michel, Carl Zeiss Jena (ca. 1943)". Zeiss Microscopy library.
  11. ^ Burgess M (15 October 2003). "Celebrating 50 years of Live Cell Imaging" (PDF). Carl Zeiss UK and The Royal Microscopical Society. London: The Biochemical Society.
  12. ^ Gundlach H. (PDF) (Press release). Carl Zeiss AG. Archived from the original (PDF) on March 22, 2014.
  13. ^ "The Nobel Prize in Physics 1953". Nobel Media AB.
  14. ^ von Dassow G, Verbrugghe KJ, Miller AL, Sider JR, Bement WM. "Cellular division in purple urchin embryo". The Cell — an image library.
  15. ^ Stockert JC, Blázquez-Castro A (2017). Fluorescence Microscopy in Life Sciences. Bentham Science Publishers. ISBN 978-1-68108-519-7. Retrieved 24 December 2017.
  16. ^ Stephens DJ, Allan VJ (April 2003). "Light microscopy techniques for live cell imaging". Science. 300 (5616): 82–86. Bibcode:2003Sci...300...82S. CiteSeerX 10.1.1.702.4732. doi:10.1126/science.1082160. PMID 12677057. S2CID 33199613.
  17. ^ Ge J, Wood DK, Weingeist DM, Prasongtanakij S, Navasumrit P, Ruchirawat M, Engelward BP (June 2013). "Standard fluorescent imaging of live cells is highly genotoxic". Cytometry. Part A. 83 (6): 552–560. doi:10.1002/cyto.a.22291. PMC 3677558. PMID 23650257.
  18. ^ Velicky P, Miguel E, Michalska JM, Lyudchik J, Wei D, Lin Z, Watson JF, Troidl J, Beyer J, Ben-Simon Y, Sommer C, Jahr W, Cenameri A, Broichhagen J, Grant S, Jonas P, Novarino G, Pfister H, Bickel B, Danzl JG (July 2023). "Dense 4D nanoscale reconstruction of living brain tissue". Nature Methods. 20 (8): 1256–1265. doi:10.1038/s41592-023-01936-6. PMC 10406607. PMID 37429995.
  19. ^ Janicke B. "Digital holographic microscopy video showing cell division of unlabeled JIMT-1 breast cancer cells". The Cell — an image library.
  20. ^ Park Y, Depeursinge C, Popescu, G (2018). "Quantitative phase imaging in biomedicine". Nature Photonics. 12 (10): 578–589. Bibcode:2018NaPho..12..578P. doi:10.1038/s41566-018-0253-x. PMID 26648557. S2CID 126144855.
  21. ^ Cuche E, Bevilacqua F, Depeursinge C (1999). "Digital holography for quantitative phase-contrast imaging". Optics Letters. 24 (5): 291–293. Bibcode:1999OptL...24..291C. doi:10.1364/OL.24.000291. PMID 18071483. S2CID 38085266.
  22. ^ Rosen J, Brooker G (2008). "Non-scanning motionless fluorescence three-dimensional holographic microscopy". Nature Photonics. 2 (3): 190–195. Bibcode:2008NaPho...2..190R. doi:10.1038/nphoton.2007.300. S2CID 17818065.
  23. ^ Wonshik C, Fang-Yen C, Badizadegan K, Oh S, Lue N, Dasari R, Feld M (2007). "Tomographic phase microscopy". Nature Methods. 4 (9): 717–719. doi:10.1038/nmeth1078. PMID 17694065. S2CID 205418034.
  24. ^ a b Cotte Y, Toy F, Jourdain P, Pavillon N, Boss D, Magistretti P, Marquet P, Depeursinge C (2013). "Marker-free phase nanoscopy". Nature Photonics. 7 (2): 113–117. Bibcode:2013NaPho...7..113C. doi:10.1038/nphoton.2012.329. S2CID 16407188.
  25. ^ Jensen EC (January 2013). "Overview of live-cell imaging: requirements and methods used". Anatomical Record. 296 (1): 1–8. doi:10.1002/ar.22554. PMID 22907880. S2CID 35790454.
  26. ^ Waters JC (2013). "Live-cell fluorescence imaging". Digital Microscopy. Methods in Cell Biology. Vol. 114. pp. 125–150. doi:10.1016/B978-0-12-407761-4.00006-3. ISBN 9780124077614. PMID 23931505.
  27. ^ a b c d Hibbs AR (2004). Confocal microscopy for biologists. New York: Kluwer Academic/Plenum Publishers. ISBN 978-0306484681. OCLC 54424872.
  28. ^ Mansfield SM, Kino GS (1990-12-10). "Solid immersion microscope". Applied Physics Letters. 57 (24): 2615–2616. Bibcode:1990ApPhL..57.2615M. doi:10.1063/1.103828.
  29. ^ Keller HE (2006), "Objective Lenses for Confocal Microscopy", Handbook of Biological Confocal Microscopy, Springer US, pp. 145–161, doi:10.1007/978-0-387-45524-2_7, ISBN 9780387259215, S2CID 34412257
  30. ^ Amos, W. B.; White, J. G. (2003-09-01). "How the Confocal Laser Scanning Microscope entered Biological Research". Biology of the Cell. 95 (6): 335–342. doi:10.1016/S0248-4900(03)00078-9. PMID 14519550. S2CID 34919506.
  31. ^ Anderson GP, Nerurkar NL (2002-12-20). "Improved fluoroimmunoassays using the dye Alexa Fluor 647 with the RAPTOR, a fiber optic biosensor 7". Journal of Immunological Methods. 271 (1–2): 17–24. doi:10.1016/S0022-1759(02)00327-7. ISSN 0022-1759. PMID 12445725.
  32. ^ a b Frigault MM, Lacoste J, Swift JL, Brown CM (March 2009). "Live-cell microscopy - tips and tools". Journal of Cell Science. 122 (Pt 6): 753–767. doi:10.1242/jcs.033837. PMID 19261845.
  33. ^ Magidson V, Khodjakov A (2013). "Circumventing photodamage in live-cell microscopy". Digital Microscopy. Methods in Cell Biology. Vol. 114. pp. 545–560. doi:10.1016/B978-0-12-407761-4.00023-3. ISBN 9780124077614. PMC 3843244. PMID 23931522.
  34. ^ Rost FW (1992–1995). Fluorescence microscopy. Cambridge: Cambridge University Press. ISBN 978-0521236416. OCLC 23766227.
  35. ^ Laissue PP, Alghamdi RA, Tomancak P, Reynaud EG, Shroff H (June 2017). "Assessing phototoxicity in live fluorescence imaging". Nature Methods. 14 (7): 657–661. doi:10.1038/nmeth.4344. hdl:21.11116/0000-0002-8B80-0. PMID 28661494. S2CID 6844352.
  36. ^ Ettinger A, Wittmann T (2014). "Fluorescence live cell imaging". Quantitative Imaging in Cell Biology. Methods in Cell Biology. Vol. 123. pp. 77–94. doi:10.1016/B978-0-12-420138-5.00005-7. ISBN 9780124201385. PMC 4198327. PMID 24974023.
  37. ^ Pawley JB (2006). Handbook of biological confocal microscopy (3rd ed.). New York, NY: Springer. ISBN 9780387455242. OCLC 663880901.
  38. ^ Watu A, Metussin N, Yasin HM, Usman A (2018). "The total antioxidant capacity and fluorescence imaging of selected plant leaves commonly consumed in Brunei Darussalam". AIP Conference Proceedings. 1933 (1): 020001. Bibcode:2018AIPC.1933b0001W. doi:10.1063/1.5023935.
  39. ^ Sandoz, Patrick A.; Tremblay, Christopher; Equis, Sebastien; Pop, Sorin; Pollaro, Lisa; Cotte, Yann; van der Goot, F. Gisou; Frechin, Mathieu (2018-09-04). "Label free 3D analysis of organelles in living cells by refractive index shows pre-mitotic organelle spinning in mammalian stem cells". bioRxiv 10.1101/407239.

External links edit

  • Florida State University — Introduction to Live Cell Imaging Techniques

live, cell, imaging, more, historic, details, time, lapse, microscopy, study, living, cells, using, time, lapse, microscopy, used, scientists, obtain, better, understanding, biological, function, through, study, cellular, dynamics, pioneered, first, decade, 21. For more historic details see time lapse microscopy Live cell imaging is the study of living cells using time lapse microscopy It is used by scientists to obtain a better understanding of biological function through the study of cellular dynamics 1 Live cell imaging was pioneered in the first decade of the 21st century One of the first time lapse microcinematographic films of cells ever made was made by Julius Ries showing the fertilization and development of the sea urchin egg 2 Since then several microscopy methods have been developed to study living cells in greater detail with less effort A newer type of imaging using quantum dots have been used as they are shown to be more stable 3 The development of holotomographic microscopy has disregarded phototoxicity and other staining derived disadvantages by implementing digital staining based on cells refractive index 4 5 A live cell microscope Live cell microscopes are generally inverted To keep cells alive during observation the microscopes are commonly enclosed in a micro cell incubator the transparent box Contents 1 Overview 2 Types of microscopy used 2 1 Phase contrast 2 2 Fluorescent 2 3 Quantitative phase contrast 2 4 Holotomography 3 Instrumentation and optics 3 1 Lens designs 3 1 1 Low magnification dry 3 1 2 Oil immersion high NA 3 1 3 Water immersion 3 1 4 Dipping 4 Phototoxicity and photobleaching 5 See also 6 References 7 External linksOverview editBiological systems exist as a complex interplay of countless cellular components interacting across four dimensions to produce the phenomenon called life While it is common to reduce living organisms to non living samples to accommodate traditional static imaging tools the further the sample deviates from the native conditions the more likely the delicate processes in question will exhibit perturbations 6 The onerous task of capturing the true physiological identity of living tissue therefore requires high resolution visualization across both space and time within the parent organism 7 The technological advances of live cell imaging designed to provide spatiotemporal images of subcellular events in real time serves an important role for corroborating the biological relevance of physiological changes observed during experimentation Due to their contiguous relationship with physiological conditions live cell assays are considered the standard for probing complex and dynamic cellular events 8 As dynamic processes such as migration cell development and intracellular trafficking increasingly become the focus of biological research techniques capable of capturing 3 dimensional data in real time for cellular networks in situ and entire organisms in vivo will become indispensable tools in understanding biological systems The general acceptance of live cell imaging has led to a rapid expansion in the number of practitioners and established a need for increased spatial and temporal resolution without compromising the health of the cell 9 Types of microscopy used editPhase contrast edit source source source Phase contrast microscopy time lapse video of dividing rattle grasshopper spermatocytes This historic film which popularized phase contrast microscopy was made in the early 1940s by Kurt Michel of the Carl Zeiss company 10 Main article Phase contrast microscopy Before the introduction of the phase contrast microscope it was difficult to observe living cells As living cells are translucent they must be stained to be visible in a traditional light microscope Unfortunately the process of staining cells generally kills them With the invention of the phase contrast microscopy it became possible to observe unstained living cells in detail After its introduction in the 1940s live cell imaging rapidly became popular using phase contrast microscopy 11 The phase contrast microscope was popularized through a series of time lapse movies see video recorded using a photographic film camera 12 Its inventor Frits Zernike was awarded the Nobel Prize in 1953 13 Other later phase contrast techniques used to observe unstained cells are Hoffman modulation and differential interference contrast microscopy Fluorescent edit source source source source Fluorescent microscopy time lapse video of a dividing purple sea urchin embryo 14 Main article Fluorescent microscopy Phase contrast microscopy does not have the capacity to observe specific proteins or other organic chemical compounds which form the complex machinery of a cell Synthetic and organic fluorescent stains have therefore been developed to label such compounds making them observable by fluorescent microscopy see video 15 Fluorescent stains are however phototoxic invasive and bleach when observed This limits their use when observing living cells over extended periods of time Non invasive phase contrast techniques are therefore often used as a vital complement to fluorescent microscopy in live cell imaging applications 16 17 Deep learning assisted fluorescence microscopy methods however help to reduced light burden and phototoxicity and allow even repeated high resolution live imaging 18 Quantitative phase contrast edit source source source Quantitative phase contrast microscopy video of a dividing breast cancer cells 19 Main article Quantitative phase contrast microscopy As a result of the rapid increase in pixel density of digital image sensors quantitative phase contrast microscopy has emerged as an alternative microscopy method for live cell imaging 20 21 Quantitative phase contrast microscopy has an advantage over fluorescent and phase contrast microscopy in that it is both non invasive and quantitative in its nature Due to the narrow focal depth of conventional microscopy live cell imaging is to a large extent currently limited to observing cells on a single plane Most implementations of quantitative phase contrast microscopy allow creating and focusing images at different focal planes from a single exposure This opens up the future possibility of 3 dimensional live cell imaging by means of fluorescence techniques 22 Quantitative phase contrast microscopy with rotational scanning allow 3D time lapse images of living cells to be acquired at high resolution 23 24 4 Holotomography edit Holotomography HT is a laser technique to measure three dimensional refractive index RI tomogram of a microscopic sample such as biological cells and tissues Because the RI can serve as an intrinsic imaging contrast for transparent or phase objects measurements of RI tomograms can provide label free quantitative imaging of microscopic phase objects In order to measure 3D RI tomogram of samples HT employs the principle of holographic imaging and inverse scattering Typically multiple 2D holographic images of a sample are measured at various illumination angles employing the principle of interferometric imaging Then a 3D RI tomogram of the sample is reconstructed from these multiple 2D holographic images by inversely solving light scattering in the sample The principle of HT is very similar to X ray computed tomography CT or CT scan CT scan measures multiple 2D X ray images of a human body at various illumination angles and a 3D tomogram X ray absorptivity is then retrieved using the inverse scattering theory Both the X ray CT and laser HT shares the same governing equation Helmholtz equation the wave equation for a monochromatic wavelength HT is also known as optical diffraction tomography The combination of holography and rotational scanning allows long term label free live cell recordings Non invasive optical nanoscopy can achieve such a lateral resolution by using a quasi 2p holographic detection scheme and complex deconvolution The spatial frequencies of the imaged cell do not make any sense to the human eye But these scattered frequencies are converted into a hologram and synthesize a bandpass which has a resolution double the one normally available Holograms are recorded from different illumination directions on the sample plane and observe sub wavelength tomographic variations of the specimen Nanoscale apertures serve to calibrate the tomographic reconstruction and to characterize the imaging system by means of the coherent transfer function This gives rise to realistic inverse filtering and guarantees true complex field reconstruction 24 In conclusion the 2 terminologies of i optical resolution the real one and ii sampling resolution the one on the screen are separated for 3D holotomographic microscopy Instrumentation and optics editLive cell imaging represents a careful compromise between acquiring the highest resolution image and keeping the cells alive for as long as possible 25 As a result live cell microscopists face a unique set of challenges that are often overlooked when working with fixed specimens Moreover live cell imaging often employs special optical system and detector specifications For example ideally the microscopes used in live cell imaging would have high signal to noise ratios fast image acquisition rates to capture time lapse video of extracellular events and maintaining the long term viability of the cells 26 However optimizing even a single facet of image acquisition can be resource intensive and should be considered on a case by case basis Lens designs edit nbsp A Upright lens configuration B Inverted lens configuration Low magnification dry edit In cases where extra space between the objective and the specimen is required to work with the sample a dry lens can be used potentially requiring additional adjustments of the correction collar which changes the location of the lens in the objective to account for differences in imaging chambers Special objective lenses are designed with correction collars that correct for spherical aberrations while accounting for the cover slip thickness In high numerical aperture NA dry objective lenses the correction collar adjustment ring changes the position of a movable lens group to account for differences in the way the outside of the lens focuses light relative to the center Although lens aberrations are inherent in all lens designs they become more problematic in dry lenses where resolution retention is key 27 Oil immersion high NA edit Oil immersion is a technique that can increase image resolution by immersing the lens and the specimen in oil with a high refractive index Since light bends when it passes between media with different refractive indexes by placing oil with the same refractive index as glass between the lens and the slide two transitions between refractive indices can be avoided 28 However for most applications it is recommended that oil immersion be used with fixed dead specimens because live cells require an aqueous environment and the mixing of oil and water can cause severe spherical aberrations For some applications silicone oil can be used to produce more accurate image reconstructions Silicone oil is an attractive medium because it has a refractive index that is close to that of living cells allowing to produce high resolution images while minimizing spherical aberrations 27 Water immersion edit Live cell imaging requires a sample in an aqueous environment that is often 50 to 200 micrometers away from the cover glass Therefore water immersion lenses can help achieve a higher resolving power due to the fact that both the environment and the cells themselves will be close to the refractive index of water Water immersion lenses are designed to be compatible with the refractive index of water and usually have a corrective collar that allows adjustment of the objective Additionally because of the higher refractive index of water water immersion lenses have a high numerical aperture and can produce images superior to oil immersion lens when resolving planes deeper than 0 µm 27 Dipping edit Another solution for live cell imaging is the dipping lens These lenses are a subset of water immersion lenses that do not require a cover slip and can be dipped directly into the aqueous environment of the sample One of the main advantages of the dipping lens is that it has a long effective working distance 29 Since a cover slip is not required this type of lens can approach the surface of the specimen and as a result the resolution is limited by the restraints imposed by spherical aberration rather than the physical limitations of the cover slip Although dipping lenses can be very useful they are not ideal for all experiments since the act of dipping the lens can disturb the cells in the sample Additionally since the incubation chamber must be open to the lens changes in the sample environment due to evaporation must be closely monitored 27 Phototoxicity and photobleaching editToday most live imaging techniques rely on either high illumination regimes or fluorescent labelling both inducing phototoxicity and compromising the ability to keep cells unperturbed and alive over time Since our knowledge of biology is driven by observation it is key to minimize the perturbations induced by the imaging technique The rise of confocal microscopy is closely correlated with accessibility of high power lasers which are able to achieve high intensities of light excitation However the high power output can damage sensitive fluorophores so the lasers usually run significantly below their full power output 30 Overexposure to light can result in photodamage due to photobleaching or phototoxicity The effects of photobleaching can significantly reduce the quality of fluorescent images and in recent years there has been a significant demand for longer lasting commercial fluorophores One solution the Alexa Fluor series show little to no fading even at high laser intensities 31 Under physiological conditions many cells and tissue types are exposed to only low levels of light 32 As a result it is important to minimize the exposure of live cells to high doses of ultraviolet UV infrared IR or fluorescence exciting wavelengths of light which can damage DNA raise cellular temperatures and cause photobleaching respectively 33 High energy photons absorbed by the fluorophores and the sample are emitted at longer wavelengths proportional to the Stokes shift 34 However cellular organelles can be damaged when the photon energy produces chemical and molecular changes rather than being re emitted 35 It is believed that the primary culprit in the light induced toxicity experienced by live cells is a result of free radicals produced by the excitation of fluorescent molecules 32 These free radicals are highly reactive and cause the destruction of cellular components which can result in non physiological behavior One method of minimizing photo damage is to lower the oxygen concentration in the sample to avoid the formation of reactive oxygen species 36 However this method is not always possible in live cell imaging and may require additional intervention Another method for reducing the effects of free radicals in the sample is the use of antifade reagents Unfortunately most commercial antifade reagents cannot be used in live cell imaging because of their toxicity 37 Instead natural free radical scavengers such as vitamin C or vitamin E can be used without substantially altering physiological behavior on shorter time scales 38 Phototoxicity free live cell imaging has recently been developed and commercialised Holotomographic microscopy avoids phototoxicity thanks to its low power laser laser class 1 0 2 mW mm2 4 5 39 See also editCytometry Quantitative phase imaging Time lapse microscopy Live single cell imagingReferences edit Baker M August 2010 Cellular imaging Taking a long hard look Nature 466 7310 1137 1140 Bibcode 2010Natur 466 1137B doi 10 1038 4661137a PMID 20740018 S2CID 205056946 Landecker H October 2009 Seeing things from microcinematography to live cell imaging Nature Methods 6 10 707 709 doi 10 1038 nmeth1009 707 PMID 19953685 S2CID 6521488 Jaiswal JK Goldman ER Mattoussi H Simon SM October 2004 Use of quantum dots for live cell imaging Nature Methods 1 1 73 78 doi 10 1038 nmeth1004 73 PMID 16138413 S2CID 13339279 a b c Pollaro L Equis S Dalla Piazza B Cotte Y 2016 Stain free 3D Nanoscopy of Living Cells Optik amp Photonik 11 38 42 doi 10 1002 opph 201600008 a b Pollaro L Dalla Piazza B Cotte Y 2015 Digital Staining Microscopy of Live Cells Without Invasive Chemicals PDF Microscopy Today 23 4 12 17 doi 10 1017 S1551929515000590 S2CID 135982205 Petroll W M Jester J V Cavanagh H D May 1994 In vivo confocal imaging general principles and applications Scanning 16 3 131 149 ISSN 0161 0457 PMID 8038913 Meijering Erik Dzyubachyk Oleh Smal Ihor 2012 01 01 Methods for Cell and Particle Tracking Imaging and Spectroscopic Analysis of Living Cells Optical and Spectroscopic Techniques Methods in Enzymology Vol 504 pp 183 200 doi 10 1016 B978 0 12 391857 4 00009 4 ISBN 9780123918574 ISSN 0076 6879 PMID 22264535 Archived from the original on 2022 05 05 Retrieved 2019 12 02 Allan Victoria J Stephens David J 2003 04 04 Light Microscopy Techniques for Live Cell Imaging Science 300 5616 82 86 Bibcode 2003Sci 300 82S CiteSeerX 10 1 1 702 4732 doi 10 1126 science 1082160 ISSN 1095 9203 PMID 12677057 S2CID 33199613 Dance Amber 2018 03 27 Live cell imaging Deeper faster wider Science AAAS Retrieved 2018 12 17 Michel K Historic time lapse movie by Dr Kurt Michel Carl Zeiss Jena ca 1943 Zeiss Microscopy library Burgess M 15 October 2003 Celebrating 50 years of Live Cell Imaging PDF Carl Zeiss UK and The Royal Microscopical Society London The Biochemical Society Gundlach H 50 Years Ago Frits Zernike 1888 1966 Got the Nobel Prize in Physics for the Development of the Phase Contrast Method PDF Press release Carl Zeiss AG Archived from the original PDF on March 22 2014 The Nobel Prize in Physics 1953 Nobel Media AB von Dassow G Verbrugghe KJ Miller AL Sider JR Bement WM Cellular division in purple urchin embryo The Cell an image library Stockert JC Blazquez Castro A 2017 Fluorescence Microscopy in Life Sciences Bentham Science Publishers ISBN 978 1 68108 519 7 Retrieved 24 December 2017 Stephens DJ Allan VJ April 2003 Light microscopy techniques for live cell imaging Science 300 5616 82 86 Bibcode 2003Sci 300 82S CiteSeerX 10 1 1 702 4732 doi 10 1126 science 1082160 PMID 12677057 S2CID 33199613 Ge J Wood DK Weingeist DM Prasongtanakij S Navasumrit P Ruchirawat M Engelward BP June 2013 Standard fluorescent imaging of live cells is highly genotoxic Cytometry Part A 83 6 552 560 doi 10 1002 cyto a 22291 PMC 3677558 PMID 23650257 Velicky P Miguel E Michalska JM Lyudchik J Wei D Lin Z Watson JF Troidl J Beyer J Ben Simon Y Sommer C Jahr W Cenameri A Broichhagen J Grant S Jonas P Novarino G Pfister H Bickel B Danzl JG July 2023 Dense 4D nanoscale reconstruction of living brain tissue Nature Methods 20 8 1256 1265 doi 10 1038 s41592 023 01936 6 PMC 10406607 PMID 37429995 Janicke B Digital holographic microscopy video showing cell division of unlabeled JIMT 1 breast cancer cells The Cell an image library Park Y Depeursinge C Popescu G 2018 Quantitative phase imaging in biomedicine Nature Photonics 12 10 578 589 Bibcode 2018NaPho 12 578P doi 10 1038 s41566 018 0253 x PMID 26648557 S2CID 126144855 Cuche E Bevilacqua F Depeursinge C 1999 Digital holography for quantitative phase contrast imaging Optics Letters 24 5 291 293 Bibcode 1999OptL 24 291C doi 10 1364 OL 24 000291 PMID 18071483 S2CID 38085266 Rosen J Brooker G 2008 Non scanning motionless fluorescence three dimensional holographic microscopy Nature Photonics 2 3 190 195 Bibcode 2008NaPho 2 190R doi 10 1038 nphoton 2007 300 S2CID 17818065 Wonshik C Fang Yen C Badizadegan K Oh S Lue N Dasari R Feld M 2007 Tomographic phase microscopy Nature Methods 4 9 717 719 doi 10 1038 nmeth1078 PMID 17694065 S2CID 205418034 a b Cotte Y Toy F Jourdain P Pavillon N Boss D Magistretti P Marquet P Depeursinge C 2013 Marker free phase nanoscopy Nature Photonics 7 2 113 117 Bibcode 2013NaPho 7 113C doi 10 1038 nphoton 2012 329 S2CID 16407188 Jensen EC January 2013 Overview of live cell imaging requirements and methods used Anatomical Record 296 1 1 8 doi 10 1002 ar 22554 PMID 22907880 S2CID 35790454 Waters JC 2013 Live cell fluorescence imaging Digital Microscopy Methods in Cell Biology Vol 114 pp 125 150 doi 10 1016 B978 0 12 407761 4 00006 3 ISBN 9780124077614 PMID 23931505 a b c d Hibbs AR 2004 Confocal microscopy for biologists New York Kluwer Academic Plenum Publishers ISBN 978 0306484681 OCLC 54424872 Mansfield SM Kino GS 1990 12 10 Solid immersion microscope Applied Physics Letters 57 24 2615 2616 Bibcode 1990ApPhL 57 2615M doi 10 1063 1 103828 Keller HE 2006 Objective Lenses for Confocal Microscopy Handbook of Biological Confocal Microscopy Springer US pp 145 161 doi 10 1007 978 0 387 45524 2 7 ISBN 9780387259215 S2CID 34412257 Amos W B White J G 2003 09 01 How the Confocal Laser Scanning Microscope entered Biological Research Biology of the Cell 95 6 335 342 doi 10 1016 S0248 4900 03 00078 9 PMID 14519550 S2CID 34919506 Anderson GP Nerurkar NL 2002 12 20 Improved fluoroimmunoassays using the dye Alexa Fluor 647 with the RAPTOR a fiber optic biosensor 7 Journal of Immunological Methods 271 1 2 17 24 doi 10 1016 S0022 1759 02 00327 7 ISSN 0022 1759 PMID 12445725 a b Frigault MM Lacoste J Swift JL Brown CM March 2009 Live cell microscopy tips and tools Journal of Cell Science 122 Pt 6 753 767 doi 10 1242 jcs 033837 PMID 19261845 Magidson V Khodjakov A 2013 Circumventing photodamage in live cell microscopy Digital Microscopy Methods in Cell Biology Vol 114 pp 545 560 doi 10 1016 B978 0 12 407761 4 00023 3 ISBN 9780124077614 PMC 3843244 PMID 23931522 Rost FW 1992 1995 Fluorescence microscopy Cambridge Cambridge University Press ISBN 978 0521236416 OCLC 23766227 Laissue PP Alghamdi RA Tomancak P Reynaud EG Shroff H June 2017 Assessing phototoxicity in live fluorescence imaging Nature Methods 14 7 657 661 doi 10 1038 nmeth 4344 hdl 21 11116 0000 0002 8B80 0 PMID 28661494 S2CID 6844352 Ettinger A Wittmann T 2014 Fluorescence live cell imaging Quantitative Imaging in Cell Biology Methods in Cell Biology Vol 123 pp 77 94 doi 10 1016 B978 0 12 420138 5 00005 7 ISBN 9780124201385 PMC 4198327 PMID 24974023 Pawley JB 2006 Handbook of biological confocal microscopy 3rd ed New York NY Springer ISBN 9780387455242 OCLC 663880901 Watu A Metussin N Yasin HM Usman A 2018 The total antioxidant capacity and fluorescence imaging of selected plant leaves commonly consumed in Brunei Darussalam AIP Conference Proceedings 1933 1 020001 Bibcode 2018AIPC 1933b0001W doi 10 1063 1 5023935 Sandoz Patrick A Tremblay Christopher Equis Sebastien Pop Sorin Pollaro Lisa Cotte Yann van der Goot F Gisou Frechin Mathieu 2018 09 04 Label free 3D analysis of organelles in living cells by refractive index shows pre mitotic organelle spinning in mammalian stem cells bioRxiv 10 1101 407239 External links editFlorida State University Introduction to Live Cell Imaging Techniques Retrieved from https en wikipedia org w index php title Live cell imaging amp oldid 1192041203, wikipedia, wiki, book, books, library,