fbpx
Wikipedia

Cellulose insulation

Cellulose insulation is plant fiber used in wall and roof cavities to insulate, draught proof and reduce noise. Building insulation in general is low-thermal-conductivity material used to reduce building heat loss and gain and reduce noise transmission.

Cellulose insulation
Cellulose insulation is often blown into building spaces through hoses from special blowing equipment in this case mounted inside a truck.
insulation of the floor
room wall

History of cellulose insulation

The word cellulose comes from the French word cellule for a living cell and glucose which is a sugar.

The main house of US president Thomas Jefferson's plantation Monticello was insulated with a form of cellulose in 1772.[1] Cellulose was used more widely as an insulation material in Scandinavia from the 1920s.[2] Many types of cellulosic materials have been used, including newspaper, cardboard, cotton, straw, sawdust, hemp and corncob. Modern cellulose insulation, made with recycled newspaper using grinding and dust-removing machines and adding a fire retardant, began in the 1950s and came into general use in the US in the 1970s.

The market for insulation increased following the oil embargo of 1973–74, which caused energy costs for heating to skyrocket across the US, leading to increased interest in energy conservation measures. Insulation gained significant US national attention as a cheap and available technology to increase the energy efficiency of homes. In 1977, following a particularly severe winter, a tax credit was given for US homeowners who installed insulation.

While in 1976 there were roughly 100 cellulose insulation firms with 125 plants in the US, by 1978 there were more than 350 firms with more than 500 plants1. Cellulose insulation was produced locally by small manufacturers who purchased ready-to-operate machines and offered a cheap and easy low-tech production process. Other than some constraints created by a shortage of boric acid for use as fire retardant, cellulose captured an increased share of the market due to lower costs and its suitability for retrofits. Meanwhile, fiberglass and rockwool producers found it difficult to keep up with the demand for insulation from their customers.

Due to complaints by retailers, contractors and consumers about price, safety and quality control problems, the US federal government began enacting insulation standards beginning in 1978. There was a great concern that the growth in cellulose manufactures was leading to improperly or insufficiently treating insulation against the threat of fire, although there were no reliable national statistics. This led to the US Federal Consumer Products Safety Commission (CPSC) passing 16 CFR Part 1209, which set safety standards covering four product attributes for cellulose insulation only: settled density, corrosiveness, critical radiant flux and smoldering combustion. Another regulation passed was the "R-value Rule," placing clear limitations on the claims that manufacturing and marketing firms can make about their product.

The costs incurred by increasing testing for fire resistance required by CPSC made cellulose more expensive, and the bad publicity helped decrease demand. Small producers of cellulose insulation were either unable to meet the testing requirements and went out of business, or they merged with other small manufacturers. In 1985 the CPSC asked Congress to repeal the flammability standard after further studies. By 1991 only 61 cellulose producers remained in the US.[3]

The fiberglass industry meanwhile benefited from most of the regulations passed by the federal government. The heavy lobbying by the more centralized fiberglass and mineral insulation manufacturers helped pass the tough fire standards for cellulose insulation. These standards were reinforced by technical bulletins published by the Mineral Insulation Manufacturers Association (currently known as the North American Insulation Manufacturers Association) that promoted fire hazard claims against cellulose insulation. These claims were not independently verified, faced little scientific review, or were purposefully misleading and untrue .[citation needed]

Currently cellulose insulation has increased again in use in the United States. Part of the reason for this growth could be related to studies that suggest cellulose may actually protect a building from damage in a fire better than fiberglass because cellulose is denser and restricts the oxygen necessary to burn structural members. Several National Research Council Canada studies[4] have backed these claims. Another major reason for the comeback of cellulose might be because of the increased interest in green building. Cellulose has the highest recycled content of any insulation material and also has less embodied energy than fiberglass and other furnace-produced mineral insulation.

Manufacture

Cellulose insulation is often made by hammer milling waste newspaper. The newspaper is treated with chemicals, such as boric acid, to retard the spread of fire.

Products

Four major types of loose-fill cellulose products have been developed under a variety of brand names. These are generally characterized as dry cellulose, spray applied cellulose, stabilized cellulose, and low dust cellulose. These types are used in different parts of a building and for different reasons.

Dry cellulose (loose fill)

 
blowing equipment(Dry cellulose)

Dry cellulose is used in retrofitting old homes by blowing the cellulose into holes drilled into the tops of the walls. It can also be blown into a new wall construction by using temporary retainers or netting that is clamped in place then removed once the cellulose has reached the appropriate density. This form of application does settle as much as 30%–40%. Look to the coverage chart on any product application instruction. R-value based on settled thickness. Use of given instruction charts are for estimating purposes only. Job conditions, application techniques and settings on equipment will influence actual coverage. Do not add water to this product. Due to variance in application moisture levels and temperatures cellulose will settle. Settling could leave gaps in a wall as the insulation compacts vertically, or it could leave space between a floor and the insulation beneath it. In addition, a dense-pack option can be used to reduce settling and further minimize air gaps. Dense-pack can only be done in a closed cavity by placing pressure on the cavity, and should be done only by an experienced installer.

Loose fill in walls is an antiquated technique of using cellulose in wall cavities. The home performance industry and its accrediting bodies support the dense-pack standard of insulating wall cavities, which does not settle. This method stops the stack effect and convective loops in wall cavities.

Spray-applied cellulose (wet-spray cellulose)

Spray-applied cellulose is used for applying cellulose to new wall construction. The differences are the addition of water to the cellulose while spraying as well as adding some kind of moisture retardant such as chlorine[citation needed] to prevent mold cultures. In some cases the insulation might also mix in a very small percentage of adhesive or activate a dry adhesive present in the cellulose. Wet-spray allows application without the need for a temporary retainer. In addition, wet-spray allows for an even better seal of the insulated cavity against air infiltration and eliminates settling problems. Wet-spray installation requires that the wall be allowed to dry for a minimum of 24 hours (or until maximum of 25% moisture is reached) before being covered.[5]

Stabilized cellulose

Stabilized cellulose is used most often in attic/roof insulation. It is applied with a very small amount of water to activate an adhesive of some kind. This reduces settling and decreases the amount of cellulose needed. This can prove advantageous at reducing the overall weight of the product on the ceiling drywall helping prevent possible sag. This application is ideal for sloped roofs and has been approved for 5:12 (41.66%) slopes.[5]

Low-dust cellulose

The last major type of cellulose insulation on the market is low-dust variety. Nuisance levels of dust are created during application of most types of dry insulation causing the need for simple dust masks to be worn during installation. This kind of cellulose has a small percentage of oil or similar dust dampener added. This may also be appropriate to homes where people are sensitive to newsprint or paper dust (though new dust will not be created after installation).

Advantages of cellulose insulation

Thermal performance

The thermal performance of loose filled cellulose compares favourably to other types of low cost insulation, but is lower than that of polyurethane and polyisocyanurate foams. The thermal conductivity of loose-fill cellulose is approximately 40 mW/m·K (R-value: metric R2.6 per 100 mm; imperial R3.8 per inch) which is about the same as or slightly better than glass wool or rock wool. This doesn’t represent the whole picture of thermal performance. Other important aspects are how well the building envelope is sealed[clarification needed] from air infiltration, convective airflows, and thermal bridging.

Cellulose is very good at fitting around items in walls like pipes and wiring, leaving few air pockets that can reduce the overall efficiency of the wall. Dense pack cellulose can seal walls from air infiltration while providing the density to limit convection, when installed properly. The University of Colorado School of Architecture and Planning did a study that compared two seemingly identical test structures, one insulated with cellulose and the other with fiberglass. The cellulose insulation lost 26.4% less heat energy over time compared to the fiberglass insulation. It also was shown to tighten the structure more than 30%.[6] Subsequent real world surveys have cellulose performing 20–30% better at reducing energy used for heating than fiberglass.

Compared to closed cell, Polyurethane foam insulation (R=5.5 to 6.5 per inch), cellulose has a lower R-value per inch, but is much less expensive; foam has a higher cost per equivalent R-value.[citation needed]

Long-term cost savings

Annual savings from insulating vary widely and depend on several factors, including insulation thickness, original wall performance, local climate, heating/cooling use, airtightness of other building elements and so on.

One installer claims cellulose insulation "can save homeowners 20 to 50 percent on their utility bills".[7]

Sound insulation

Insulation reduces sound travelling through walls and between floor levels. Cellulose provides mass and damping. This reduces noise in 2 ways, it reduces the lateral movement of sheetrock and attenuates the passage of sound along cavities. Cellulose is approximately three times denser than fiberglass, providing a slight improvement in sound reduction.

Mold and pest control

The borates in cellulose insulation provide added control against mold. Installations have shown that even several months of water saturation and improper installation did not result in mold.[8]

It is a common misconception that the mere presence of crude borates in cellulose insulation provides pest control properties to the product. While boric acid itself does kill self-grooming insects if ingested, it must be presented to an insect in both sufficient concentration and in an ingestible form in order to achieve insect fatality. Proper testing of products containing borates must be performed in order to determine whether dosage and presentation are sufficient to kill insects. Once tested, registration with the EPA as a pesticide is required before a product may be touted as having pesticidal capabilities in the US.

Fire retardation

The borate treatment also gives cellulose the highest (Class I) fire safety rating. Many cellulose companies use a blend of ammonium sulfate and borate.

Vapor barrier

A vapor barrier may not be needed with cellulose insulation. For example, recent studies have shown that air movement is the primary method by which excessive moisture can accumulate in mild marine climate such as Portland, OR, US.[9] An insulation that fills the wall cavity completely (such as cellulose or foam) can help prevent moisture problems. Recommendations against using vapor barriers with cellulose insulation are supported by studies, even though they classify cellulose as vapor permeable.[10]

In addition, cellulose acts to distribute moisture throughout the cavity, preventing the buildup of moisture in one area and helping to dry the moisture more quickly. Cellulose manufacturers do not recommend the installation of a vapor barrier with cellulose.[10]

Most US city codes require a vapor barrier for any external wall. Most US cities will consider an appeal against the requirement if proper reasoning is provided. In March 2008 the US city of Portland, Oregon, approved an appeal to waive the requirement for a vapor barrier/retarder when using cellulose insulation.[11] Fundamental to any appeal is stating that recent studies show air movement is the primary problem for vapor, that cellulose is an effective barrier to air movement, and that cellulose acts to diffuse vapor.

Disadvantages

The R-value of 3.6 to 3.8 per inch[citation needed] is good but not the best.[citation needed] Material cost per R-value is good but labor cost goes up because it takes more material and time to install than fiberglass insulation at the same R-Value[citation needed].

Dust

Cellulose contains small particles which can be blown into the house through inadequate seals around fixtures or small holes.[12][13]

Installation expertise and building codes

In some areas it can be difficult to locate installers that are experienced with cellulose. An experienced installer understands how to correctly dense-pack loose fill dry cellulose, how to best apply stabilized (partly wet) cellulose on sloped surfaces, and the proper time required for wet-spray cellulose to dry.

As with other non-batt insulation, US city and regional/state building codes may not be updated for cellulose insulation. Homeowners should call the city to verify that the insulation will be approved, and it may be necessary to provide product specifications to the city. This is not difficult, and the installer and the manufacturer should both be willing to handle this process, saving the homeowner any true effort.

Slumping

If improperly installed, loose fill cellulose could settle after application. In some situations this could leave areas of wall uninsulated. With correct training in installation methods and quality control techniques this is ruled out by installing to tested densities preventing any future settlement.

Weight

For a given R-value, loose cellulose weighs roughly three times as much per square foot as loose fiberglass.[14] Ceiling structures should be inspected for signs of weakness before choosing a material for insulating the ceilings of existing structures.[15]

Offgassing

Many cellulose companies use a blend of ammonium sulfate and borate for fire retardation. Although ammonium sulfate is normally odorless, unexplained emission of ammonia and a resulting ammonia smell has been found in some cases.[16]

Mold

There is some evidence of increased mold infestation inside buildings insulated with wet spray dense pack cellulose especially when used with a vapor barrier.[17]

Environmental properties

Insulation of any type helps make buildings more energy-efficient. Depending on the structure and manufacturer, using cellulose insulation could contribute to obtaining LEED credits from the US Green Building Council certification program.[18]

Recycled content

Cellulose is composed of 75–85% recycled paper fiber, usually post-consumer waste newsprint. The other 15% is a fire retardant such as boric acid or ammonium sulphate. Cellulose has the highest recycled content of any insulation available. For example, fiberglass has a maximum amount of 50% recycled content.

Low toxicity and environmental impact of raw materials

The non-recycled components of cellulose insulation are still environmentally preferable to the raw materials of foam insulation. Unlike foam insulations, many of which use HFC or HCFC blowing agents[citation needed] which have global warming potential higher than that of carbon dioxide, cellulose does not produce significant gaseous emissions.

Toxicity of the raw materials of insulation types is typically highest during manufacture or installation. Neither is a significant issue with cellulose.

OSHA states that cellulose is a dust nuisance, requiring a dust mask during installation.

Embodied energy

The embodied energy of cellulose insulation is the lowest of the popular insulation types. It requires 20 to 40 times as much energy to produce furnace-made insulation materials compared to cellulose.[citation needed] Cellulose is made by electrically powered machines while mineral insulation is made in fuel powered furnaces,[citation needed] reducing this advantage to a degree, as electricity generation is less than 50% efficient. Cellulose is made with locally available paper,[citation needed] while mineral insulation factories ship materials and products over greater distances.

Cellulose insulation uses borates for fire retardation. Borates are a non-renewable mined product.

See also

References

  1. ^ Brett French. "Cellulose Insulation Used In Historic Yellowstone Photography Store". The Billings Gazette, May 30, 2019. Accessed June 8, 2021.
  2. ^ Bozsaky, Dávid (2010). "The historical development of thermal insulation materials". Periodica Polytechnica Architecture. 41 (2): 49–56. doi:10.3311/pp.ar.2010-2.02. ISSN 1789-3437.
  3. ^ Cellulose Insulation Manufacturers Association, http://www.cellulose.org/
  4. ^ Fire Resistance Tests on Cellulose and Glass Fiber Insulated Wood Stud Shear Walls, Kodur, V.K.R.; Sultan, M.A.; Latour, J.C.; Leroux, P.; Monette, R.C., IRC-IR-806, , Quote: "...Results from fire tests F21, F21A, F22A and F32 can be used to indicate the effect of insulation types on the fire resistance of load-bearing wood stud shear walls (see Figure 16). The failure of the glass fibre insulated wall assembly (F21 and F21A) occurred at 42 and 43 minutes respectively, while the failure of the rock fibre and cellulose insulated wall assemblies occurred at 54 and 51 minutes respectively. As shown in Figure 18, these results suggest that the use of cellulose fibre insulation provides a higher fire resistance compared to glass fibre insulation, but a lower fire resistance compared to rock fibre insulation..."
  5. ^ a b ICC Legacy Report ER-2833 – Cocoon Thermal and Sound Insulation Products, ICC Evaluation Services, Inc., http://www.icc-es.org
  6. ^ Second hand source: Energy conservation. Cellulose vs fiberglass. The Colorado Study,
  7. ^ "HGTV Pro.com – Best Practices: Cellulose Insulation".
  8. ^ . Archived from the original on May 16, 2008.
  9. ^ . The Plans Examiner. City of Portland Oregon. March 2007. p. 6–7. Archived from the original on 13 September 2018.
  10. ^ a b "Discover why homes and building don't require an air/vapor barrier when using cellulose insulation". Cellulose Insulation Manufacturers Association. Retrieved 6 September 2022.
  11. ^ "Appeal 4996". The City of Portland, Oregon. 26 March 2008.
  12. ^ . Archived from the original on 2011-11-04. Retrieved 2011-04-07.
  13. ^ "NTP Toxicity Study Report on the Atmospheric Characterization, Particle Size, Chemical Composition, and Workplace Exposure Assessment of Cellulose Insulation" (PDF). National Toxology Program. U.S. Department of Health and Human Services. August 2006. (PDF) from the original on February 22, 2022. Retrieved November 8, 2022.
  14. ^ Weights of Building Materials May 16, 2011, at the Wayback Machine Boise Cascade Engineered Wood Products Tech Note GE-1, p. 1, retrieved Sept. 17, 2010
  15. ^ How to Insulate a Ceiling Bonneville Power Administration, retrieved Sept. 17, 2010
  16. ^ (PDF). Archived from the original (PDF) on July 16, 2011.
  17. ^ Godish, TJ; Godish, DR (2006). "Mold infestation of wet spray-applied cellulose insulation". J Air Waste Manag Assoc. 56 (1): 90–5. doi:10.1080/10473289.2006.10464434. PMID 16499151.
  18. ^ LEED. U.S. Green Building Council, 19 Nov. 2015. Web. <http://www.usgbc.org/leed>

External links

  • The Cellulose Insulation Manufacturers' Association

Further reading

  • McGrath, Ed (1981). The Super Insulated House; A working guide for owner-builders, architects, carpenters and contractors. Fairbanks: That New Publishing Company.
  • Home Insulation: Hearings before the Subcommittee on oversight and investigations of the committee on interstate and foreign commerce; House of Representatives Ninety-fifth Congress; Second Session; February 21, 22, and 23, 1978 Serial No. 95-81
  • Enforcement of a cellulose insulation safety standard; Hearings before the Subcommittee on oversight and investigations and the Subcommittee on Consumer Protection and Finance of the committee on interstate and foreign commerce; House of Representatives Ninety-fifth Congress; Second Session; April 19, 1978; Serial No. 95-100

cellulose, insulation, this, article, needs, additional, citations, verification, please, help, improve, this, article, adding, citations, reliable, sources, unsourced, material, challenged, removed, find, sources, news, newspapers, books, scholar, jstor, nove. This article needs additional citations for verification Please help improve this article by adding citations to reliable sources Unsourced material may be challenged and removed Find sources Cellulose insulation news newspapers books scholar JSTOR November 2015 Learn how and when to remove this template message Cellulose insulation is plant fiber used in wall and roof cavities to insulate draught proof and reduce noise Building insulation in general is low thermal conductivity material used to reduce building heat loss and gain and reduce noise transmission Cellulose insulation Cellulose insulation is often blown into building spaces through hoses from special blowing equipment in this case mounted inside a truck insulation of the floor room wall Contents 1 History of cellulose insulation 2 Manufacture 3 Products 3 1 Dry cellulose loose fill 3 2 Spray applied cellulose wet spray cellulose 3 3 Stabilized cellulose 3 4 Low dust cellulose 4 Advantages of cellulose insulation 4 1 Thermal performance 4 2 Long term cost savings 4 3 Sound insulation 4 4 Mold and pest control 4 5 Fire retardation 4 6 Vapor barrier 5 Disadvantages 5 1 Dust 5 2 Installation expertise and building codes 5 3 Slumping 5 4 Weight 5 5 Offgassing 5 6 Mold 6 Environmental properties 6 1 Recycled content 6 2 Low toxicity and environmental impact of raw materials 6 3 Embodied energy 7 See also 8 References 9 External links 10 Further readingHistory of cellulose insulation EditThe word cellulose comes from the French word cellule for a living cell and glucose which is a sugar The main house of US president Thomas Jefferson s plantation Monticello was insulated with a form of cellulose in 1772 1 Cellulose was used more widely as an insulation material in Scandinavia from the 1920s 2 Many types of cellulosic materials have been used including newspaper cardboard cotton straw sawdust hemp and corncob Modern cellulose insulation made with recycled newspaper using grinding and dust removing machines and adding a fire retardant began in the 1950s and came into general use in the US in the 1970s The market for insulation increased following the oil embargo of 1973 74 which caused energy costs for heating to skyrocket across the US leading to increased interest in energy conservation measures Insulation gained significant US national attention as a cheap and available technology to increase the energy efficiency of homes In 1977 following a particularly severe winter a tax credit was given for US homeowners who installed insulation While in 1976 there were roughly 100 cellulose insulation firms with 125 plants in the US by 1978 there were more than 350 firms with more than 500 plants1 Cellulose insulation was produced locally by small manufacturers who purchased ready to operate machines and offered a cheap and easy low tech production process Other than some constraints created by a shortage of boric acid for use as fire retardant cellulose captured an increased share of the market due to lower costs and its suitability for retrofits Meanwhile fiberglass and rockwool producers found it difficult to keep up with the demand for insulation from their customers Due to complaints by retailers contractors and consumers about price safety and quality control problems the US federal government began enacting insulation standards beginning in 1978 There was a great concern that the growth in cellulose manufactures was leading to improperly or insufficiently treating insulation against the threat of fire although there were no reliable national statistics This led to the US Federal Consumer Products Safety Commission CPSC passing 16 CFR Part 1209 which set safety standards covering four product attributes for cellulose insulation only settled density corrosiveness critical radiant flux and smoldering combustion Another regulation passed was the R value Rule placing clear limitations on the claims that manufacturing and marketing firms can make about their product The costs incurred by increasing testing for fire resistance required by CPSC made cellulose more expensive and the bad publicity helped decrease demand Small producers of cellulose insulation were either unable to meet the testing requirements and went out of business or they merged with other small manufacturers In 1985 the CPSC asked Congress to repeal the flammability standard after further studies By 1991 only 61 cellulose producers remained in the US 3 The fiberglass industry meanwhile benefited from most of the regulations passed by the federal government The heavy lobbying by the more centralized fiberglass and mineral insulation manufacturers helped pass the tough fire standards for cellulose insulation These standards were reinforced by technical bulletins published by the Mineral Insulation Manufacturers Association currently known as the North American Insulation Manufacturers Association that promoted fire hazard claims against cellulose insulation These claims were not independently verified faced little scientific review or were purposefully misleading and untrue citation needed Currently cellulose insulation has increased again in use in the United States Part of the reason for this growth could be related to studies that suggest cellulose may actually protect a building from damage in a fire better than fiberglass because cellulose is denser and restricts the oxygen necessary to burn structural members Several National Research Council Canada studies 4 have backed these claims Another major reason for the comeback of cellulose might be because of the increased interest in green building Cellulose has the highest recycled content of any insulation material and also has less embodied energy than fiberglass and other furnace produced mineral insulation Manufacture EditCellulose insulation is often made by hammer milling waste newspaper The newspaper is treated with chemicals such as boric acid to retard the spread of fire Products EditFour major types of loose fill cellulose products have been developed under a variety of brand names These are generally characterized as dry cellulose spray applied cellulose stabilized cellulose and low dust cellulose These types are used in different parts of a building and for different reasons Dry cellulose loose fill Edit blowing equipment Dry cellulose Dry cellulose is used in retrofitting old homes by blowing the cellulose into holes drilled into the tops of the walls It can also be blown into a new wall construction by using temporary retainers or netting that is clamped in place then removed once the cellulose has reached the appropriate density This form of application does settle as much as 30 40 Look to the coverage chart on any product application instruction R value based on settled thickness Use of given instruction charts are for estimating purposes only Job conditions application techniques and settings on equipment will influence actual coverage Do not add water to this product Due to variance in application moisture levels and temperatures cellulose will settle Settling could leave gaps in a wall as the insulation compacts vertically or it could leave space between a floor and the insulation beneath it In addition a dense pack option can be used to reduce settling and further minimize air gaps Dense pack can only be done in a closed cavity by placing pressure on the cavity and should be done only by an experienced installer Loose fill in walls is an antiquated technique of using cellulose in wall cavities The home performance industry and its accrediting bodies support the dense pack standard of insulating wall cavities which does not settle This method stops the stack effect and convective loops in wall cavities Spray applied cellulose wet spray cellulose Edit Spray applied cellulose is used for applying cellulose to new wall construction The differences are the addition of water to the cellulose while spraying as well as adding some kind of moisture retardant such as chlorine citation needed to prevent mold cultures In some cases the insulation might also mix in a very small percentage of adhesive or activate a dry adhesive present in the cellulose Wet spray allows application without the need for a temporary retainer In addition wet spray allows for an even better seal of the insulated cavity against air infiltration and eliminates settling problems Wet spray installation requires that the wall be allowed to dry for a minimum of 24 hours or until maximum of 25 moisture is reached before being covered 5 Stabilized cellulose Edit Stabilized cellulose is used most often in attic roof insulation It is applied with a very small amount of water to activate an adhesive of some kind This reduces settling and decreases the amount of cellulose needed This can prove advantageous at reducing the overall weight of the product on the ceiling drywall helping prevent possible sag This application is ideal for sloped roofs and has been approved for 5 12 41 66 slopes 5 Low dust cellulose Edit The last major type of cellulose insulation on the market is low dust variety Nuisance levels of dust are created during application of most types of dry insulation causing the need for simple dust masks to be worn during installation This kind of cellulose has a small percentage of oil or similar dust dampener added This may also be appropriate to homes where people are sensitive to newsprint or paper dust though new dust will not be created after installation Advantages of cellulose insulation EditThermal performance Edit The thermal performance of loose filled cellulose compares favourably to other types of low cost insulation but is lower than that of polyurethane and polyisocyanurate foams The thermal conductivity of loose fill cellulose is approximately 40 mW m K R value metric R2 6 per 100 mm imperial R3 8 per inch which is about the same as or slightly better than glass wool or rock wool This doesn t represent the whole picture of thermal performance Other important aspects are how well the building envelope is sealed clarification needed from air infiltration convective airflows and thermal bridging Cellulose is very good at fitting around items in walls like pipes and wiring leaving few air pockets that can reduce the overall efficiency of the wall Dense pack cellulose can seal walls from air infiltration while providing the density to limit convection when installed properly The University of Colorado School of Architecture and Planning did a study that compared two seemingly identical test structures one insulated with cellulose and the other with fiberglass The cellulose insulation lost 26 4 less heat energy over time compared to the fiberglass insulation It also was shown to tighten the structure more than 30 6 Subsequent real world surveys have cellulose performing 20 30 better at reducing energy used for heating than fiberglass Compared to closed cell Polyurethane foam insulation R 5 5 to 6 5 per inch cellulose has a lower R value per inch but is much less expensive foam has a higher cost per equivalent R value citation needed Long term cost savings Edit Annual savings from insulating vary widely and depend on several factors including insulation thickness original wall performance local climate heating cooling use airtightness of other building elements and so on One installer claims cellulose insulation can save homeowners 20 to 50 percent on their utility bills 7 Sound insulation Edit Insulation reduces sound travelling through walls and between floor levels Cellulose provides mass and damping This reduces noise in 2 ways it reduces the lateral movement of sheetrock and attenuates the passage of sound along cavities Cellulose is approximately three times denser than fiberglass providing a slight improvement in sound reduction Mold and pest control Edit The borates in cellulose insulation provide added control against mold Installations have shown that even several months of water saturation and improper installation did not result in mold 8 It is a common misconception that the mere presence of crude borates in cellulose insulation provides pest control properties to the product While boric acid itself does kill self grooming insects if ingested it must be presented to an insect in both sufficient concentration and in an ingestible form in order to achieve insect fatality Proper testing of products containing borates must be performed in order to determine whether dosage and presentation are sufficient to kill insects Once tested registration with the EPA as a pesticide is required before a product may be touted as having pesticidal capabilities in the US Fire retardation Edit The borate treatment also gives cellulose the highest Class I fire safety rating Many cellulose companies use a blend of ammonium sulfate and borate Vapor barrier Edit A vapor barrier may not be needed with cellulose insulation For example recent studies have shown that air movement is the primary method by which excessive moisture can accumulate in mild marine climate such as Portland OR US 9 An insulation that fills the wall cavity completely such as cellulose or foam can help prevent moisture problems Recommendations against using vapor barriers with cellulose insulation are supported by studies even though they classify cellulose as vapor permeable 10 In addition cellulose acts to distribute moisture throughout the cavity preventing the buildup of moisture in one area and helping to dry the moisture more quickly Cellulose manufacturers do not recommend the installation of a vapor barrier with cellulose 10 Most US city codes require a vapor barrier for any external wall Most US cities will consider an appeal against the requirement if proper reasoning is provided In March 2008 the US city of Portland Oregon approved an appeal to waive the requirement for a vapor barrier retarder when using cellulose insulation 11 Fundamental to any appeal is stating that recent studies show air movement is the primary problem for vapor that cellulose is an effective barrier to air movement and that cellulose acts to diffuse vapor Disadvantages EditThe R value of 3 6 to 3 8 per inch citation needed is good but not the best citation needed Material cost per R value is good but labor cost goes up because it takes more material and time to install than fiberglass insulation at the same R Value citation needed Dust Edit Cellulose contains small particles which can be blown into the house through inadequate seals around fixtures or small holes 12 13 Installation expertise and building codes Edit In some areas it can be difficult to locate installers that are experienced with cellulose An experienced installer understands how to correctly dense pack loose fill dry cellulose how to best apply stabilized partly wet cellulose on sloped surfaces and the proper time required for wet spray cellulose to dry As with other non batt insulation US city and regional state building codes may not be updated for cellulose insulation Homeowners should call the city to verify that the insulation will be approved and it may be necessary to provide product specifications to the city This is not difficult and the installer and the manufacturer should both be willing to handle this process saving the homeowner any true effort Slumping Edit If improperly installed loose fill cellulose could settle after application In some situations this could leave areas of wall uninsulated With correct training in installation methods and quality control techniques this is ruled out by installing to tested densities preventing any future settlement Weight Edit For a given R value loose cellulose weighs roughly three times as much per square foot as loose fiberglass 14 Ceiling structures should be inspected for signs of weakness before choosing a material for insulating the ceilings of existing structures 15 Offgassing Edit Many cellulose companies use a blend of ammonium sulfate and borate for fire retardation Although ammonium sulfate is normally odorless unexplained emission of ammonia and a resulting ammonia smell has been found in some cases 16 Mold Edit There is some evidence of increased mold infestation inside buildings insulated with wet spray dense pack cellulose especially when used with a vapor barrier 17 Environmental properties EditInsulation of any type helps make buildings more energy efficient Depending on the structure and manufacturer using cellulose insulation could contribute to obtaining LEED credits from the US Green Building Council certification program 18 Recycled content Edit Cellulose is composed of 75 85 recycled paper fiber usually post consumer waste newsprint The other 15 is a fire retardant such as boric acid or ammonium sulphate Cellulose has the highest recycled content of any insulation available For example fiberglass has a maximum amount of 50 recycled content Low toxicity and environmental impact of raw materials Edit The non recycled components of cellulose insulation are still environmentally preferable to the raw materials of foam insulation Unlike foam insulations many of which use HFC or HCFC blowing agents citation needed which have global warming potential higher than that of carbon dioxide cellulose does not produce significant gaseous emissions Toxicity of the raw materials of insulation types is typically highest during manufacture or installation Neither is a significant issue with cellulose OSHA states that cellulose is a dust nuisance requiring a dust mask during installation Embodied energy Edit The embodied energy of cellulose insulation is the lowest of the popular insulation types It requires 20 to 40 times as much energy to produce furnace made insulation materials compared to cellulose citation needed Cellulose is made by electrically powered machines while mineral insulation is made in fuel powered furnaces citation needed reducing this advantage to a degree as electricity generation is less than 50 efficient Cellulose is made with locally available paper citation needed while mineral insulation factories ship materials and products over greater distances Cellulose insulation uses borates for fire retardation Borates are a non renewable mined product See also EditCellulose insulating material plantReferences Edit Brett French Cellulose Insulation Used In Historic Yellowstone Photography Store The Billings Gazette May 30 2019 Accessed June 8 2021 Bozsaky David 2010 The historical development of thermal insulation materials Periodica Polytechnica Architecture 41 2 49 56 doi 10 3311 pp ar 2010 2 02 ISSN 1789 3437 Cellulose Insulation Manufacturers Association http www cellulose org Fire Resistance Tests on Cellulose and Glass Fiber Insulated Wood Stud Shear Walls Kodur V K R Sultan M A Latour J C Leroux P Monette R C IRC IR 806 archive backup Quote Results from fire tests F21 F21A F22A and F32 can be used to indicate the effect of insulation types on the fire resistance of load bearing wood stud shear walls see Figure 16 The failure of the glass fibre insulated wall assembly F21 and F21A occurred at 42 and 43 minutes respectively while the failure of the rock fibre and cellulose insulated wall assemblies occurred at 54 and 51 minutes respectively As shown in Figure 18 these results suggest that the use of cellulose fibre insulation provides a higher fire resistance compared to glass fibre insulation but a lower fire resistance compared to rock fibre insulation a b ICC Legacy Report ER 2833 Cocoon Thermal and Sound Insulation Products ICC Evaluation Services Inc http www icc es org Second hand source Energy conservation Cellulose vs fiberglass The Colorado Study archive backup HGTV Pro com Best Practices Cellulose Insulation Cellulose insulation winning market share in Colorado Built Green Colorado Steve Andres October 5 2007 Archived from the original on May 16 2008 Managing Moisture in Houses The Plans Examiner City of Portland Oregon March 2007 p 6 7 Archived from the original on 13 September 2018 a b Discover why homes and building don t require an air vapor barrier when using cellulose insulation Cellulose Insulation Manufacturers Association Retrieved 6 September 2022 Appeal 4996 The City of Portland Oregon 26 March 2008 Cellulose Insulation Problems Archived from the original on 2011 11 04 Retrieved 2011 04 07 NTP Toxicity Study Report on the Atmospheric Characterization Particle Size Chemical Composition and Workplace Exposure Assessment of Cellulose Insulation PDF National Toxology Program U S Department of Health and Human Services August 2006 Archived PDF from the original on February 22 2022 Retrieved November 8 2022 Weights of Building Materials Archived May 16 2011 at the Wayback Machine Boise Cascade Engineered Wood Products Tech Note GE 1 p 1 retrieved Sept 17 2010 How to Insulate a Ceiling Bonneville Power Administration retrieved Sept 17 2010 SCI Engineering Newsletter report PDF Archived from the original PDF on July 16 2011 Godish TJ Godish DR 2006 Mold infestation of wet spray applied cellulose insulation J Air Waste Manag Assoc 56 1 90 5 doi 10 1080 10473289 2006 10464434 PMID 16499151 LEED U S Green Building Council 19 Nov 2015 Web lt http www usgbc org leed gt External links EditThe Cellulose Insulation Manufacturers Association The Australian Cellulose Insulation Manufacturers Association CIMA Technical Bulletin 2 Standard practice for installing cellulose building insulationFurther reading EditMcGrath Ed 1981 The Super Insulated House A working guide for owner builders architects carpenters and contractors Fairbanks That New Publishing Company Home Insulation Hearings before the Subcommittee on oversight and investigations of the committee on interstate and foreign commerce House of Representatives Ninety fifth Congress Second Session February 21 22 and 23 1978 Serial No 95 81 Enforcement of a cellulose insulation safety standard Hearings before the Subcommittee on oversight and investigations and the Subcommittee on Consumer Protection and Finance of the committee on interstate and foreign commerce House of Representatives Ninety fifth Congress Second Session April 19 1978 Serial No 95 100 Retrieved from https en wikipedia org w index php title Cellulose insulation amp oldid 1120778067, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.