fbpx
Wikipedia

Argox

Argox is the informal name for a scuba diving breathing gas consisting of argon and oxygen. Occasionally the term argonox has been used to mean the same mix. The blend may consist of varying fractions of argon and oxygen, depending on its intended use. The mixture is made with the same gas blending techniques used to make nitrox, except that for argox, the argon is added to the initial pure oxygen partial-fill, instead of air.

Argox is essentially a theoretical diving gas, being rarely, if ever, used, and usually thought to have no practical applications where its benefits outweigh its drawbacks.[citation needed]

Possible uses

Human exploration of Mars

Argox, or half-argox/half-nitrox is a possible oxygen mixture for human exploration of Mars due to the relative abundance of Argon in the Martian atmosphere. The Martian atmosphere is composed of approximately: 95% CO2, 1.9% argon, 1.9% nitrogen. While it is possible for humans to breathe pure oxygen, a pure oxygen atmosphere was implicated in the Apollo 1 fire. As such, Mars habitats may have a need for additional gases. One possibility is to take nitrogen and argon from the atmosphere of Mars; however, they are hard to separate from each other. As a result, a Mars habitat may use 40% argon, 40% nitrogen, and 20% oxygen. Another concept for breathing air is to use re-usable amine bead carbon dioxide scrubbers. While one carbon dioxide scrubber filters the astronauts' air, the other is vented to the Mars atmosphere.[1][2]

Drysuit inflation

The helium in the breathing gas trimix, which is used to avoid nitrogen narcosis on deep dives, gives the gas a high thermal conductivity compared with air, making it inappropriate for drysuit inflation. Divers breathing trimix with drysuits usually inflate their drysuits with their decompression gas (usually nitrox or oxygen). A few carry yet another small cylinder, dedicated to drysuit inflation, containing argon.[3]

A second class of divers at intermediate depths of 30–45 metres (100–150 ft) which do not require trimix sometimes carry a pony bottle for emergencies, as is taught in many deep diving courses. Such second bottles are often 3 litres, and may be mounted in various ways from tank bracket to sling mounting. This second bottle can be used for argox, if a drysuit is used.[original research?]

Some[who?] argue that an argox blend with oxygen content similar to that of air could be used as a suit inflation gas in place of pure argon, as such a blend would only have a slightly higher thermal conductivity than pure argon, and unlike pure argon, would be breathable in an emergency. However, there are many problems with the use of suit inflation gas as an emergency breathing gas. Argon is a very narcotic gas, meaning that it could only be breathed at comparatively shallow depths above 20 metres (66 ft). However, in an emergency this is enough for adequate decompression time at typical decompression levels between 3 metres (10 ft) and 9 metres (30 ft), and would save a diver from a direct ascent. The small size of typical very small suit inflation cylinders mean that their contents would quickly be exhausted if breathed, but this is not so of larger ponies.

The thermal conductivity of argon is 68% of that of air or nitrox, hence its use in drysuit inflation. Using argox 20% would slightly degrade this to 74% of that of air.

Argon is far more narcotic (about 2.3 times more) than the cheaper and more readily available nitrogen at depth, so it loses out to nitrogen in all roles as a primary breathing gas. If the maximum operating depth for air owing to narcosis is taken to be 40 metres (130 ft), then for 20% argox (20% O2, 80% Ar) it would be 14.5 metres (48 ft).[a]

Decompression gas

It has been theorised on the basis of the theory of isobaric counterdiffusion that argon, because of its higher molecular mass compared with nitrogen (40 vs. 28 u), may cause less inert gas on-loading, if used as a decompression gas, instead of nitrox.[4] The MOD of argox mixes containing more than about 47% oxygen are limited by oxygen MOD (assuming 1.5 atm ppO2) rather than by argon narcosis MOD. The maximal MOD for argox mixes occurs at 47% oxygen and 53% argon, and is about 73 fsw (22 m). This depth is the theoretical maximum which can be safely attained with any two-component argon/oxygen mix: a larger fraction of oxygen than about 50% will result in oxygen toxicity before this depth, and a larger fraction of argon than about 50% will result in argon narcosis before this depth.

However, as argox is more narcotic than nitrogen (causing it to be more dangerous if a decompression mix is accidentally breathed), and because argox is moderately more expensive than nitrox, and mostly because there has been little research done into the actual (vs. theoretical) physiological aspects of breathing argon during decompression, argox is not currently recommended by any professional agency for this purpose.[5]

Although there is little research relating to divers decompressing using argon mixes, there have been scientific studies of astronauts decompressing using argox. The provisional results of those studies indicated higher levels of decompression sickness when argox was used, rather than pure oxygen; however, using pure oxygen is not an option for decompression at the pressures for which argox would be used in diving, and no direct comparison of argon to nitrogen was done.[6] There is also a certain amount of anecdotal evidence within the diving community that informal experimentation with decompression on argon mixtures has resulted in a high incidence of decompression sickness, but no formal studies.[7]

See also

Notes

  1. ^ Assuming oxygen, nitrogen and air all have roughly equal narcotic potential, and argon is 2.3 times that, the pressure (P) at which the narcotic potential of 20% argox is the same as air at 5 bar (i.e. 40 metres) can be found from P x (0.2 + (0.8 x 2.3)) = 5. That gives P=2.45 bar, which corresponds to 14.5 metres.

References

  1. ^ "The Caves of Mars - Martian Air Breathing Mice". highmars.org. Archived from the original on 24 July 2007. Retrieved 12 June 2015
  2. ^ Courtland, Rachel (30 September 2015). "Suiting Up for the Red Planet". IEEE Spectrum. 52 (10): 36–38. doi:10.1109/MSPEC.2015.7274192. S2CID 46224902. Retrieved 9 January 2019.
  3. ^ Nuckols, Marshall L; Giblo, J; Wood-Putnam, JL (2008). . Undersea and Hyperbaric Medicine. 35 (4). Archived from the original on 2009-04-12. Retrieved 2008-10-24.{{cite journal}}: CS1 maint: unfit URL (link)
  4. ^ D'Aoust BG, Stayton L, Smith LS (September 1980). . Undersea Biomed Res. 7 (3): 199–209. PMID 7423658. Archived from the original on April 23, 2009. Retrieved 2008-08-28.{{cite journal}}: CS1 maint: unfit URL (link)
  5. ^ Rahn H, Rokitka MA (March 1976). . Undersea Biomed Res. 3 (1): 25–34. PMID 1273982. Archived from the original on April 27, 2009. Retrieved 2008-08-28.{{cite journal}}: CS1 maint: unfit URL (link)
  6. ^ Pilmanis Andrew A, Balldin UI, Webb James T, Krause KM (December 2003). "Staged decompression to 3.5 psi using argon-oxygen and 100% oxygen breathing mixtures". Aviat Space Environ Med. 74 (12): 1243–50. PMID 14692466. Retrieved 2008-08-28.
  7. ^ Scubaboard.com (2010-03-25). "Accelerated decompression on an argon mix?". Retrieved 2011-02-02.

External links

  • Why Argon? Diving applications: Why Argon?
  • Tech Diver. . Archived from the original on 14 September 2008. Retrieved 2008-08-28. - A discussion of various rarely used and theoretical diving gases.

argox, informal, name, scuba, diving, breathing, consisting, argon, oxygen, occasionally, term, argonox, been, used, mean, same, blend, consist, varying, fractions, argon, oxygen, depending, intended, mixture, made, with, same, blending, techniques, used, make. Argox is the informal name for a scuba diving breathing gas consisting of argon and oxygen Occasionally the term argonox has been used to mean the same mix The blend may consist of varying fractions of argon and oxygen depending on its intended use The mixture is made with the same gas blending techniques used to make nitrox except that for argox the argon is added to the initial pure oxygen partial fill instead of air Argox is essentially a theoretical diving gas being rarely if ever used and usually thought to have no practical applications where its benefits outweigh its drawbacks citation needed Contents 1 Possible uses 1 1 Human exploration of Mars 1 2 Drysuit inflation 1 3 Decompression gas 2 See also 3 Notes 4 References 5 External linksPossible uses EditHuman exploration of Mars Edit Argox or half argox half nitrox is a possible oxygen mixture for human exploration of Mars due to the relative abundance of Argon in the Martian atmosphere The Martian atmosphere is composed of approximately 95 CO2 1 9 argon 1 9 nitrogen While it is possible for humans to breathe pure oxygen a pure oxygen atmosphere was implicated in the Apollo 1 fire As such Mars habitats may have a need for additional gases One possibility is to take nitrogen and argon from the atmosphere of Mars however they are hard to separate from each other As a result a Mars habitat may use 40 argon 40 nitrogen and 20 oxygen Another concept for breathing air is to use re usable amine bead carbon dioxide scrubbers While one carbon dioxide scrubber filters the astronauts air the other is vented to the Mars atmosphere 1 2 Drysuit inflation Edit The helium in the breathing gas trimix which is used to avoid nitrogen narcosis on deep dives gives the gas a high thermal conductivity compared with air making it inappropriate for drysuit inflation Divers breathing trimix with drysuits usually inflate their drysuits with their decompression gas usually nitrox or oxygen A few carry yet another small cylinder dedicated to drysuit inflation containing argon 3 A second class of divers at intermediate depths of 30 45 metres 100 150 ft which do not require trimix sometimes carry a pony bottle for emergencies as is taught in many deep diving courses Such second bottles are often 3 litres and may be mounted in various ways from tank bracket to sling mounting This second bottle can be used for argox if a drysuit is used original research Some who argue that an argox blend with oxygen content similar to that of air could be used as a suit inflation gas in place of pure argon as such a blend would only have a slightly higher thermal conductivity than pure argon and unlike pure argon would be breathable in an emergency However there are many problems with the use of suit inflation gas as an emergency breathing gas Argon is a very narcotic gas meaning that it could only be breathed at comparatively shallow depths above 20 metres 66 ft However in an emergency this is enough for adequate decompression time at typical decompression levels between 3 metres 10 ft and 9 metres 30 ft and would save a diver from a direct ascent The small size of typical very small suit inflation cylinders mean that their contents would quickly be exhausted if breathed but this is not so of larger ponies The thermal conductivity of argon is 68 of that of air or nitrox hence its use in drysuit inflation Using argox 20 would slightly degrade this to 74 of that of air Argon is far more narcotic about 2 3 times more than the cheaper and more readily available nitrogen at depth so it loses out to nitrogen in all roles as a primary breathing gas If the maximum operating depth for air owing to narcosis is taken to be 40 metres 130 ft then for 20 argox 20 O2 80 Ar it would be 14 5 metres 48 ft a Decompression gas Edit It has been theorised on the basis of the theory of isobaric counterdiffusion that argon because of its higher molecular mass compared with nitrogen 40 vs 28 u may cause less inert gas on loading if used as a decompression gas instead of nitrox 4 The MOD of argox mixes containing more than about 47 oxygen are limited by oxygen MOD assuming 1 5 atm ppO2 rather than by argon narcosis MOD The maximal MOD for argox mixes occurs at 47 oxygen and 53 argon and is about 73 fsw 22 m This depth is the theoretical maximum which can be safely attained with any two component argon oxygen mix a larger fraction of oxygen than about 50 will result in oxygen toxicity before this depth and a larger fraction of argon than about 50 will result in argon narcosis before this depth However as argox is more narcotic than nitrogen causing it to be more dangerous if a decompression mix is accidentally breathed and because argox is moderately more expensive than nitrox and mostly because there has been little research done into the actual vs theoretical physiological aspects of breathing argon during decompression argox is not currently recommended by any professional agency for this purpose 5 Although there is little research relating to divers decompressing using argon mixes there have been scientific studies of astronauts decompressing using argox The provisional results of those studies indicated higher levels of decompression sickness when argox was used rather than pure oxygen however using pure oxygen is not an option for decompression at the pressures for which argox would be used in diving and no direct comparison of argon to nitrogen was done 6 There is also a certain amount of anecdotal evidence within the diving community that informal experimentation with decompression on argon mixtures has resulted in a high incidence of decompression sickness but no formal studies 7 See also EditHeliox Hydreliox Hydrox Nitrox TrimixNotes Edit Assuming oxygen nitrogen and air all have roughly equal narcotic potential and argon is 2 3 times that the pressure P at which the narcotic potential of 20 argox is the same as air at 5 bar i e 40 metres can be found from P x 0 2 0 8 x 2 3 5 That gives P 2 45 bar which corresponds to 14 5 metres References Edit The Caves of Mars Martian Air Breathing Mice highmars org Archived from the original on 24 July 2007 Retrieved 12 June 2015 Courtland Rachel 30 September 2015 Suiting Up for the Red Planet IEEE Spectrum 52 10 36 38 doi 10 1109 MSPEC 2015 7274192 S2CID 46224902 Retrieved 9 January 2019 Nuckols Marshall L Giblo J Wood Putnam JL 2008 Thermal characteristics of diving garments when using argon as a suit inflation gas abstract Undersea and Hyperbaric Medicine 35 4 Archived from the original on 2009 04 12 Retrieved 2008 10 24 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint unfit URL link D Aoust BG Stayton L Smith LS September 1980 Separation of basic parameters of decompression using fingerling salmon Undersea Biomed Res 7 3 199 209 PMID 7423658 Archived from the original on April 23 2009 Retrieved 2008 08 28 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint unfit URL link Rahn H Rokitka MA March 1976 Narcotic potency of N2 A and N2O evaluated by the physical performance of mouse colonies at simulated depths Undersea Biomed Res 3 1 25 34 PMID 1273982 Archived from the original on April 27 2009 Retrieved 2008 08 28 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint unfit URL link Pilmanis Andrew A Balldin UI Webb James T Krause KM December 2003 Staged decompression to 3 5 psi using argon oxygen and 100 oxygen breathing mixtures Aviat Space Environ Med 74 12 1243 50 PMID 14692466 Retrieved 2008 08 28 Scubaboard com 2010 03 25 Accelerated decompression on an argon mix Retrieved 2011 02 02 External links EditWhy Argon Diving applications Why Argon Tech Diver Exotic Gases Archived from the original on 14 September 2008 Retrieved 2008 08 28 A discussion of various rarely used and theoretical diving gases Retrieved from https en wikipedia org w index php title Argox amp oldid 1119481719, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.