fbpx
Wikipedia

Virginia Graeme Baker Pool and Spa Safety Act

The Virginia Graeme Baker Pool and Spa Safety Act (VGBA) is a United States law named after Virginia Graeme Baker, who died after sustaining a pool suction-drain injury in June 2002, when the suction from a spa drain entrapped her under the water. It is incorporated as Title 14 of the U.S. Energy Independence and Security Act of 2007 (EISA Title 14, Pub.L. 110-140). This act became enforceable law on December 19, 2008.

Goals Edit

The goals of the VGBA were to enhance the safety of public and private pools and spas, to reduce child drownings, to reduce the number of suction entrapment incidents, injuries and deaths; and to educate the public on the importance of constant supervision of children in and around water.

Virginia Graeme Baker Edit

Virginia Graeme Baker was a seven-year-old girl who drowned when she was trapped underwater by the powerful suction of a hot tub drain. She was simply called "Graeme" and was the second youngest of five daughters including a twin. She was a proficient swimmer for her age and had been able to swim on her own since the age of three. Additionally, she was a member of her community swim and dive team. Her parents are Nancy and James Baker IV. James Baker is the son of former Secretary of State James Baker III.[1][2]

In June 2002, Graeme was stuck to a hot tub drain by suction. Efforts by her mother to free her were unsuccessful and when two men eventually were able to free her (postmortem), the drain broke from the force. Although Graeme drowned, her official cause of death was "suction entrapment due to a faulty drain cover". Following Graeme's death in June 2002, her mother, Nancy Baker, began work to advocate pool and spa safety. She began lobbying Congress to pass legislation to require anti-entrapment drain covers as well as other pool and spa safety devices. EISA was introduced to Congress on January 12, 2007 and signed into law on December 19, 2007 by President George W. Bush.[3]

Death of Abigail Taylor Edit

Abigail Rose Taylor was a young girl from Edina, Minnesota, whose accidental injury and eventual death led to federal legislation to improve the safety of swimming pools.[4][5]

On June 29, 2007, six-year-old Abigail's parents took her to the Minneapolis Golf Club in St. Louis Park, Minnesota. Abigail accidentally fell on the open drain of the pool and her buttocks were sucked into the aperture. The suction dislodged a large section of her small intestine, which was forcefully drawn out through the anus, a phenomenon known as transanal evisceration. Abigail lost 6.5 meters (21 feet) of her small intestine in the accident, leaving her with short bowel syndrome. Abigail was hospitalized and received a rare triple organ transplant to replace her small intestine, liver, and pancreas, all of which were damaged in the accident. She was unable to eat or drink, and she required total parenteral nutrition. Abigail died nine months after the accident because of a transplant-related cancer.[6][7]

The incident was similar to a 1993 incident in North Carolina involving Valerie Lakey. The pool drains in question in both the Taylor and the Lakey cases were manufactured by Sta-Rite, a division of Minnesota-based Pentair.[8] Lakey received a $25 million settlement with the help of lawyer (and later Senator) John Edwards.[9]

Entrapment Edit

Consumer Product Safety Commission staff began investigating reported incidents of swimming pool/spa suction entrapment incidents in the 1970s. Such incidents included entrapment of hair, body, limb, evisceration or disembowelment and mechanical entrapment of jewelry or bathing suits. From 1999 to 2007 for all age categories records were examined. In 2007, for all age categories, there were 74 reports of circulation entrapments. Individuals in the 5- to 9-year-old category had the highest frequency of entrapment reports.[10]

74 reports of circulation entrapments in 2007
Pool/Spa Deaths Injuries
Public 2 20
Residential 7 33
Unknown 0 10
Gender
Male 4 28
Female 5 35

Pool/spa accident statistics Edit

Between January 1985 and March 2002, there were 147 confirmed, recorded suction-entrapment incidents, according to Consumer Product Safety Commission records. 51 of those were hair entanglement, 79 body or limb entrapments (including three eviscerations), four mechanical (jewelry, etc) and 13 unknown. Of the 147 incidents, 36 resulted in deaths.[11] While the first documented case is unclear, lawyer John Edwards points to a case in 1974.[9]

According to the National Safety Council (NSC), 172 children under the age of 15 drowned in pools or spas between Memorial Day and Labor Day in 2010. An additional 180 children under the age of 15 were injured. The NSC is further calling for increased vigilance by parents and pool/spa owners. They suggest precautions such as four-sided fences for pool/spa areas, alarms on all doors accessing pool/spa areas, heavy duty pool covers, anti-entrapment drains and close supervision of children near pools/spas.[12]

Drain provisions Edit

A drain is defined as a plumbing fitting installed on the suction side of a pump in a pool, spa or hot tub. Drains are now required to be "unblockable." This term has previously been defined in the "definitions" section. Four main ways of keeping a drain from being blockable are outlined as: large aspect covers; long channels; large outlet grates; and circulation designs that do not include fully submerged suction outlets. In the United States, if a pool or spa does not employ an unblockable drain, it must include, at a minimum, one of the following safety systems: a safety vacuum-release system (SVRS) as defined in "definitions;" a suction-limiting vent system with a tamper-resistant atmospheric opening; a gravity drainage system that utilizes a collector tank; an automatic pump shut-off system; a device or system that disables the drain or any other system certified by the consumer product safety commission.[13]

Legal status Edit

Definitions from EISA Edit

There are 7 definitions given under title XIV of EISA 2007.

The following definitions are directly quoted out of EISA 2007:

(1) ASME/ANSI — The term 'ASME/ANSI' as applied to a safety standard means such a standard that is accredited by the American National Standards Institute and published by the American Society of Mechanical Engineers.[14]

(2) Barrier — The term 'barrier' includes a natural or constructed topographical feature that prevents unpermitted access by children to a swimming pool, and, with respect to a hot tub, a lockable cover.[14]

(3) Commission — The term 'Commission' means the Consumer Product Safety Commission.[14]

(4) Main Drain — The term 'main drain' means a submerged suction outlet typically located at the bottom of a pool or spa to conduct water to a recirculating pump.[14]

(5) Safety Vacuum Release System (SVRS) - The term 'safety vacuum release system' means a vacuum release system capable of providing vacuum release at a suction outlet caused by a high vacuum occurrence due to a suction outlet flow blockage.[14]

(6) Swimming Pool; Spa — The term 'swimming pool' or 'spa' means any outdoor or indoor structure intended for swimming or recreational bathing, including in-ground and above-ground structures, and includes hot tubs, spas, portable spas, and non-portable wading pools.[14]

(7) Unblockable Drain — The term 'unblockable drain' means a drain of any size and shape that a human body cannot sufficiently block to create a suction entrapment hazard.[14]

Sponsors of the bill Edit

Federal requirements Edit

There is a federal requirement for public pools that preempts the state or local law, as of December 19, 2008, and further regulations are in addition to it:

Sec. 1404: Top Priority for Public Pool And Spa Owners/Operators All pool/spa drain covers manufactured, distributed or entered into commerce on or after December 19, 2008 must meet ASME/ANSI A112.19.8– 2007. All public pools and spas must be retrofitted with covers that meet the ASME/ANSI A112.19.8– 2007 standard. All public pools and spas that have a single drain other than an unblockable drain must employ one or more additional options.

State requirements Edit

A pool contractor should verify that the pool and/or spa is in compliance with the federally mandated Virginia Graeme Baker Pool & Spa Safety Act which takes effect December 19, 2008. If the pool is not in compliance, the necessary steps should be taken to comply with the Act, which, in essence, specifies that:

All public pools and spas, both new and existing, shall be equipped with drain covers compliant with ASME/ANSI A112.19.8 2007 standard.

In addition, all public pools and spas with a single main drain - other than an un-blockable drain - shall also employ one or more of the following devices: separated drain system per ANSI/APSP 7, safety vacuum release system (SVRS) that complies with ANSI/ASME A112.19.17 or ASTM F2387; suction-limiting vent system; gravity drainage system; automatic pump shutoff; drain disablement; equivalent system determined by the CPSC.

The definition of un-blockable drain in the Act is a "drain sump of any size or shape that a human body cannot sufficiently block to create a suction entrapment issue."

Link to the Act: Title XIV—Pool and Spa Safety Act

Compliant drain covers Edit

The VGBA requires all drain covers to either be manufactured products or to be field fabricated outlets", in each case meeting the specific technical requirements of the act and having the necessary certification.

The PSSA requires a safe and secure connection between the cover and sump. A new, compliant cover that fits securely into a pre-existing sump is accepted under certain conditions.

SVRS devices Edit

These are used in conjunction with an approved main drain cover and skimmer. SVRS are a type of device that are tested to respond to a full vacuum, stopping and releasing a vacuum within 4.5 seconds after a drain is fully blocked. These systems must be tested and certified to be in conformance with ANSI/PSPS/ICC-7-2013 “Manufactured Safety Vacuum Release Systems (SVRS) for Residential and Commercial Swimming Pool, Spa, Hot Tub, and Wading Pool Suction Systems” or ASTM F2387 “Standard Provisional Specification for Manufactured for Swimming Pools, Spas, and Hot Tubs.” These standards establish requirements for manufactured SVRS devices: the dimensions and tolerances, materials, installation instructions, testing requirements, and markings and identification. An SVRS can be installed as an independent system or Can be incorporated as part of the pool pump.

  • Mechanical devices which let air into pump to ease the vacuum when entrapment or blockage is sensed by device.[citation needed]
  • Electro-mechanical devices that shut off pump when blockage/entrapment is sensed.[citation needed]
  • Pumps or motors with built-in software that shuts off pump when blockage/entrapment is sensed.[citation needed][16]

Compliance Edit

As of December 19, 2008, it became unlawful to manufacture for sale, offer for sale, distribute in commerce or import into the United States any pool/spa product that is not within conformity to the new pool/spa safety rule, 15 U.S.C. § 2068(a), or the new drain standards, ASME/ANSI A112.19.8.[13]

Any person who knowingly manufactures, sells, distributes or imports a device of noncompliance shall face penalties up to the maximum of $1.825 million. Congress is considering raising this amount to $10 million per offense. Imprisonment is also allowed for this offense, however sentencing term guidelines are not outlined. Criminal and civil penalties could also ensue if any person knowingly does not report the practice of another manufacturing, selling, distributing or importing a noncompliance product.[13]

Pools and spas that are not in operation on December 19, 2008 do not need to meet the new safety standards until they intend to reopen.[13]

Sources Edit

  • CONSUMER PRODUCT SAFETY COMMISSION (http://WWW.CPSC.GOV/)
  • CPSC Enforcement Position
  • Presentation on Drowning Prevention, Entrapment Prevention & Pool and Spa Safety Act (pdf)
  • CPSC Staff's Guide to Complying with the Law, October 2008 (pdf)
  • CPSC Staff Interpretation of Section 1404 of the Virginia Graeme Baker Pool and Spa Safety Act, June 18, 2008 (pdf)
  • CPSC Staff Draft Technical Guidance on Section 1406 on Minimum State Requirements for Grant Program* Public Comment Period
  • ANSI/APSP-7 Fact Sheet
  • ANSI/APSP-7 field checklist for identifying suction entrapment hazards

References Edit

  1. ^ "'She Died in My Arms': A Mother's Mission for Safe Pools". ABC News. 2008-07-23.
  2. ^ Baker, Nancy (2004-07-27). "Written Submission of Nancy Baker for the Commissions Public Hearing on July 27, 2004 in Phoenix, Arizona on suction entrapment". U.S. Consumer Product Safety Commission.
  3. ^ BBC. . Interlinked Climate & Energy Challenges. Archived from the original on August 13, 2011. Retrieved March 23, 2011.
  4. ^ a b . Star Tribune. Associated Press. 2007-07-13. Archived from the original on 2007-11-09.
  5. ^ Lerner, Maura (2007-07-06). . Star Tribune. Minneapolis. Archived from the original on 2007-07-10.
  6. ^ Taylor, Scott (2007-11-13). (PDF). Minnesota Fourth Judicial District. Archived from the original (PDF) on 2008-09-10.
  7. ^ . WSB Atlanta. Minneapolis. 5 Jul 2007. Archived from the original on 2007-07-08.
  8. ^ "Family Reaches Settlement that Guarantees $25 Million Payment". WRAL-TV. Raleigh, North Carolina. 1997-01-14.
  9. ^ a b Gamel, Kim (1997-01-15). "Girl disembowled by pool drain will get $30.9 million". Associated Press.
  10. ^ Reported Pool/Spa-Related Related Circulation/Suction Entrapments, CPCS, 2007
  11. ^ Dumas, Bob. . Pool and Spa News. Los Angeles: Hanley Wood LLC. Archived from the original on 2011-07-15.
  12. ^ National Safety Council. "CPSC releases child drowning figures". Safety + Health. CPSC. Retrieved March 23, 2011.
  13. ^ a b c d poolsafety.gov. (PDF). June 18, 2008 Staff Interpretation of Section 1404: "Federal Swimming Pool and Spa Drain Cover Standard". CPSC. Archived from the original (PDF) on October 15, 2011. Retrieved April 17, 2011.
  14. ^ a b c d e f g H.R. 6--110th Congress. "Energy Independence and Security Act of 2007". EISA 2007. govtrack.us. Retrieved March 24, 2011.
  15. ^ Schultz, Debbie. . The Need for Federal Pool Safety Legislation. house.gov. Archived from the original on April 6, 2011. Retrieved March 23, 2011.
  16. ^ Pool & Hot Tub Alliance, editor. “Facility Safety.” Pool & Spa Operator Handbook, 2nd ed., Pool & Hot Tub Alliance, 2017, pp. 186–187.

External links Edit

  • Swimming-Pool-Information.com - Web page with more information on compliant devices
  • Full text version of EISA 2007: EISA 2007
  • PoolSafety.gov
  • Poolsafety.gov A staff interpretation of new drain standards.
  • Virginia Graeme Baker's Story. Virginia Graeme Baker
  • Pool & Spa safe equipment.
  • Pool/Spa operation FAQs. FAQs
  • information on alternative bottom drain technology

virginia, graeme, baker, pool, safety, vgba, united, states, named, after, virginia, graeme, baker, died, after, sustaining, pool, suction, drain, injury, june, 2002, when, suction, from, drain, entrapped, under, water, incorporated, title, energy, independenc. The Virginia Graeme Baker Pool and Spa Safety Act VGBA is a United States law named after Virginia Graeme Baker who died after sustaining a pool suction drain injury in June 2002 when the suction from a spa drain entrapped her under the water It is incorporated as Title 14 of the U S Energy Independence and Security Act of 2007 EISA Title 14 Pub L 110 140 This act became enforceable law on December 19 2008 Wikisource has original text related to this article Virginia Graeme Baker Pool and Spa Safety Act Contents 1 Goals 2 Virginia Graeme Baker 3 Death of Abigail Taylor 4 Entrapment 5 Pool spa accident statistics 6 Drain provisions 7 Legal status 7 1 Definitions from EISA 8 Sponsors of the bill 8 1 Federal requirements 8 2 State requirements 8 3 Compliant drain covers 9 SVRS devices 10 Compliance 11 Sources 12 References 13 External linksGoals EditThe goals of the VGBA were to enhance the safety of public and private pools and spas to reduce child drownings to reduce the number of suction entrapment incidents injuries and deaths and to educate the public on the importance of constant supervision of children in and around water Virginia Graeme Baker EditVirginia Graeme Baker was a seven year old girl who drowned when she was trapped underwater by the powerful suction of a hot tub drain She was simply called Graeme and was the second youngest of five daughters including a twin She was a proficient swimmer for her age and had been able to swim on her own since the age of three Additionally she was a member of her community swim and dive team Her parents are Nancy and James Baker IV James Baker is the son of former Secretary of State James Baker III 1 2 In June 2002 Graeme was stuck to a hot tub drain by suction Efforts by her mother to free her were unsuccessful and when two men eventually were able to free her postmortem the drain broke from the force Although Graeme drowned her official cause of death was suction entrapment due to a faulty drain cover Following Graeme s death in June 2002 her mother Nancy Baker began work to advocate pool and spa safety She began lobbying Congress to pass legislation to require anti entrapment drain covers as well as other pool and spa safety devices EISA was introduced to Congress on January 12 2007 and signed into law on December 19 2007 by President George W Bush 3 Death of Abigail Taylor EditAbigail Rose Taylor was a young girl from Edina Minnesota whose accidental injury and eventual death led to federal legislation to improve the safety of swimming pools 4 5 On June 29 2007 six year old Abigail s parents took her to the Minneapolis Golf Club in St Louis Park Minnesota Abigail accidentally fell on the open drain of the pool and her buttocks were sucked into the aperture The suction dislodged a large section of her small intestine which was forcefully drawn out through the anus a phenomenon known as transanal evisceration Abigail lost 6 5 meters 21 feet of her small intestine in the accident leaving her with short bowel syndrome Abigail was hospitalized and received a rare triple organ transplant to replace her small intestine liver and pancreas all of which were damaged in the accident She was unable to eat or drink and she required total parenteral nutrition Abigail died nine months after the accident because of a transplant related cancer 6 7 The incident was similar to a 1993 incident in North Carolina involving Valerie Lakey The pool drains in question in both the Taylor and the Lakey cases were manufactured by Sta Rite a division of Minnesota based Pentair 8 Lakey received a 25 million settlement with the help of lawyer and later Senator John Edwards 9 Entrapment EditConsumer Product Safety Commission staff began investigating reported incidents of swimming pool spa suction entrapment incidents in the 1970s Such incidents included entrapment of hair body limb evisceration or disembowelment and mechanical entrapment of jewelry or bathing suits From 1999 to 2007 for all age categories records were examined In 2007 for all age categories there were 74 reports of circulation entrapments Individuals in the 5 to 9 year old category had the highest frequency of entrapment reports 10 74 reports of circulation entrapments in 2007 Pool Spa Deaths InjuriesPublic 2 20Residential 7 33Unknown 0 10GenderMale 4 28Female 5 35Pool spa accident statistics EditBetween January 1985 and March 2002 there were 147 confirmed recorded suction entrapment incidents according to Consumer Product Safety Commission records 51 of those were hair entanglement 79 body or limb entrapments including three eviscerations four mechanical jewelry etc and 13 unknown Of the 147 incidents 36 resulted in deaths 11 While the first documented case is unclear lawyer John Edwards points to a case in 1974 9 According to the National Safety Council NSC 172 children under the age of 15 drowned in pools or spas between Memorial Day and Labor Day in 2010 An additional 180 children under the age of 15 were injured The NSC is further calling for increased vigilance by parents and pool spa owners They suggest precautions such as four sided fences for pool spa areas alarms on all doors accessing pool spa areas heavy duty pool covers anti entrapment drains and close supervision of children near pools spas 12 Drain provisions EditA drain is defined as a plumbing fitting installed on the suction side of a pump in a pool spa or hot tub Drains are now required to be unblockable This term has previously been defined in the definitions section Four main ways of keeping a drain from being blockable are outlined as large aspect covers long channels large outlet grates and circulation designs that do not include fully submerged suction outlets In the United States if a pool or spa does not employ an unblockable drain it must include at a minimum one of the following safety systems a safety vacuum release system SVRS as defined in definitions a suction limiting vent system with a tamper resistant atmospheric opening a gravity drainage system that utilizes a collector tank an automatic pump shut off system a device or system that disables the drain or any other system certified by the consumer product safety commission 13 Legal status EditDefinitions from EISA Edit There are 7 definitions given under title XIV of EISA 2007 The following definitions are directly quoted out of EISA 2007 1 ASME ANSI The term ASME ANSI as applied to a safety standard means such a standard that is accredited by the American National Standards Institute and published by the American Society of Mechanical Engineers 14 2 Barrier The term barrier includes a natural or constructed topographical feature that prevents unpermitted access by children to a swimming pool and with respect to a hot tub a lockable cover 14 3 Commission The term Commission means the Consumer Product Safety Commission 14 4 Main Drain The term main drain means a submerged suction outlet typically located at the bottom of a pool or spa to conduct water to a recirculating pump 14 5 Safety Vacuum Release System SVRS The term safety vacuum release system means a vacuum release system capable of providing vacuum release at a suction outlet caused by a high vacuum occurrence due to a suction outlet flow blockage 14 6 Swimming Pool Spa The term swimming pool or spa means any outdoor or indoor structure intended for swimming or recreational bathing including in ground and above ground structures and includes hot tubs spas portable spas and non portable wading pools 14 7 Unblockable Drain The term unblockable drain means a drain of any size and shape that a human body cannot sufficiently block to create a suction entrapment hazard 14 Sponsors of the bill EditHouse Debbie Wasserman Schultz better source needed 15 Senate introduced by Mark Pryor D Ark Ted Stevens R Alaska and Chris Dodd D Conn Amy Klobuchar D Minn signed on as an original co sponsor 4 Federal requirements Edit There is a federal requirement for public pools that preempts the state or local law as of December 19 2008 and further regulations are in addition to it Sec 1404 Top Priority for Public Pool And Spa Owners Operators All pool spa drain covers manufactured distributed or entered into commerce on or after December 19 2008 must meet ASME ANSI A112 19 8 2007 All public pools and spas must be retrofitted with covers that meet the ASME ANSI A112 19 8 2007 standard All public pools and spas that have a single drain other than an unblockable drain must employ one or more additional options State requirements Edit A pool contractor should verify that the pool and or spa is in compliance with the federally mandated Virginia Graeme Baker Pool amp Spa Safety Act which takes effect December 19 2008 If the pool is not in compliance the necessary steps should be taken to comply with the Act which in essence specifies that All public pools and spas both new and existing shall be equipped with drain covers compliant with ASME ANSI A112 19 8 2007 standard In addition all public pools and spas with a single main drain other than an un blockable drain shall also employ one or more of the following devices separated drain system per ANSI APSP 7 safety vacuum release system SVRS that complies with ANSI ASME A112 19 17 or ASTM F2387 suction limiting vent system gravity drainage system automatic pump shutoff drain disablement equivalent system determined by the CPSC The definition of un blockable drain in the Act is a drain sump of any size or shape that a human body cannot sufficiently block to create a suction entrapment issue Link to the Act Title XIV Pool and Spa Safety Act Compliant drain covers Edit The VGBA requires all drain covers to either be manufactured products or to be field fabricated outlets in each case meeting the specific technical requirements of the act and having the necessary certification The PSSA requires a safe and secure connection between the cover and sump A new compliant cover that fits securely into a pre existing sump is accepted under certain conditions SVRS devices EditThese are used in conjunction with an approved main drain cover and skimmer SVRS are a type of device that are tested to respond to a full vacuum stopping and releasing a vacuum within 4 5 seconds after a drain is fully blocked These systems must be tested and certified to be in conformance with ANSI PSPS ICC 7 2013 Manufactured Safety Vacuum Release Systems SVRS for Residential and Commercial Swimming Pool Spa Hot Tub and Wading Pool Suction Systems or ASTM F2387 Standard Provisional Specification for Manufactured for Swimming Pools Spas and Hot Tubs These standards establish requirements for manufactured SVRS devices the dimensions and tolerances materials installation instructions testing requirements and markings and identification An SVRS can be installed as an independent system or Can be incorporated as part of the pool pump Mechanical devices which let air into pump to ease the vacuum when entrapment or blockage is sensed by device citation needed Electro mechanical devices that shut off pump when blockage entrapment is sensed citation needed Pumps or motors with built in software that shuts off pump when blockage entrapment is sensed citation needed 16 Compliance EditAs of December 19 2008 it became unlawful to manufacture for sale offer for sale distribute in commerce or import into the United States any pool spa product that is not within conformity to the new pool spa safety rule 15 U S C 2068 a or the new drain standards ASME ANSI A112 19 8 13 Any person who knowingly manufactures sells distributes or imports a device of noncompliance shall face penalties up to the maximum of 1 825 million Congress is considering raising this amount to 10 million per offense Imprisonment is also allowed for this offense however sentencing term guidelines are not outlined Criminal and civil penalties could also ensue if any person knowingly does not report the practice of another manufacturing selling distributing or importing a noncompliance product 13 Pools and spas that are not in operation on December 19 2008 do not need to meet the new safety standards until they intend to reopen 13 Sources EditCONSUMER PRODUCT SAFETY COMMISSION http WWW CPSC GOV CPSC Enforcement Position Presentation on Drowning Prevention Entrapment Prevention amp Pool and Spa Safety Act pdf CPSC Staff s Guide to Complying with the Law October 2008 pdf CPSC Staff Interpretation of Section 1404 of the Virginia Graeme Baker Pool and Spa Safety Act June 18 2008 pdf CPSC Staff Draft Technical Guidance on Section 1406 on Minimum State Requirements for Grant Program Public Comment Period ANSI APSP 7 Fact Sheet ANSI APSP 7 field checklist for identifying suction entrapment hazardsReferences Edit She Died in My Arms A Mother s Mission for Safe Pools ABC News 2008 07 23 Baker Nancy 2004 07 27 Written Submission of Nancy Baker for the Commissions Public Hearing on July 27 2004 in Phoenix Arizona on suction entrapment U S Consumer Product Safety Commission BBC US President Bush Signs Energy Independence and Security Act into Law 2007 Interlinked Climate amp Energy Challenges Archived from the original on August 13 2011 Retrieved March 23 2011 a b July 11 Senators introduce pool safety legislation Star Tribune Associated Press 2007 07 13 Archived from the original on 2007 11 09 Lerner Maura 2007 07 06 Newer pools minimize risk of drain accidents officials say Star Tribune Minneapolis Archived from the original on 2007 07 10 Taylor Scott 2007 11 13 Plaintiff s complaint PDF Minnesota Fourth Judicial District Archived from the original PDF on 2008 09 10 Wading Pool Drain Sucks Out Girl s Organ WSB Atlanta Minneapolis 5 Jul 2007 Archived from the original on 2007 07 08 Family Reaches Settlement that Guarantees 25 Million Payment WRAL TV Raleigh North Carolina 1997 01 14 a b Gamel Kim 1997 01 15 Girl disembowled by pool drain will get 30 9 million Associated Press Reported Pool Spa Related Related Circulation Suction Entrapments CPCS 2007 Dumas Bob Troubled Waters Pool and Spa News Los Angeles Hanley Wood LLC Archived from the original on 2011 07 15 National Safety Council CPSC releases child drowning figures Safety Health CPSC Retrieved March 23 2011 a b c d poolsafety gov Virginia Graeme Baker Pool and Spa Safety Act PDF June 18 2008 Staff Interpretation of Section 1404 Federal Swimming Pool and Spa Drain Cover Standard CPSC Archived from the original PDF on October 15 2011 Retrieved April 17 2011 a b c d e f g H R 6 110th Congress Energy Independence and Security Act of 2007 EISA 2007 govtrack us Retrieved March 24 2011 Schultz Debbie 5th Annual National Drowning Symposium The Need for Federal Pool Safety Legislation house gov Archived from the original on April 6 2011 Retrieved March 23 2011 Pool amp Hot Tub Alliance editor Facility Safety Pool amp Spa Operator Handbook 2nd ed Pool amp Hot Tub Alliance 2017 pp 186 187 External links EditSwimming Pool Information com Web page with more information on compliant devices Full text version of EISA 2007 EISA 2007 PoolSafety gov Poolsafety gov A staff interpretation of new drain standards poolsafety gov Interpretation Virginia Graeme Baker s Story Virginia Graeme Baker Pool amp Spa safe equipment Equipment Specifications and Pictures Pool Spa operation FAQs FAQs information on alternative bottom drain technology Retrieved from https en wikipedia org w index php title Virginia Graeme Baker Pool and Spa Safety Act amp oldid 1174848193, wikipedia, wiki, book, books, library,