fbpx
Wikipedia

Decompression equipment

There are several categories of decompression equipment used to help divers decompress, which is the process required to allow divers to return to the surface safely after spending time underwater at higher ambient pressures.

Decompression equipment
Surface supplied diver on diving stage
UsesEquipment used by divers to facilitate decompression
Related itemsDive computer, Decompression practice, Diving bell, Diving chamber

Decompression obligation for a given dive profile must be calculated and monitored to ensure that the risk of decompression sickness is controlled. Some equipment is specifically for these functions, both during planning before the dive and during the dive. Other equipment is used to mark the underwater position of the diver, as a position reference in low visibility or currents, or to assist the diver's ascent and control the depth.

Decompression may be shortened ("accelerated") by breathing an oxygen-rich "decompression gas" such as a nitrox blend or pure oxygen. The high partial pressure of oxygen in such decompression mixes produces the effect known as the oxygen window.[1] This decompression gas is often carried by scuba divers in side-slung cylinders. Cave divers who can only return by a single route, can leave decompression gas cylinders attached to the guideline ("stage" or "drop cylinders") at the points where they will be used.[2] Surface-supplied divers will have the composition of the breathing gas controlled at the gas panel.[3]

Divers with long decompression obligations may be decompressed inside gas filled hyperbaric chambers in the water or at the surface, and in the extreme case, saturation divers are only decompressed at the end of a project, contract, or tour of duty that may be several weeks long.

Planning and monitoring decompression edit

Equipment for planning and monitoring decompression includes decompression tables, depth gauges, timers, surface computer software, and personal decompression computers. There is a wide range of choice.

Decompression algorithms edit

 
Inert gas tension in the tissue compartments during a decompression dive with gas switching to accelerate decompression, as predicted by a decompression algorithm

A decompression algorithm is used to calculate the decompression stops needed for a particular dive profile to reduce the risk of decompression sickness occurring after surfacing at the end of a dive. The algorithm can be used to generate decompression schedules for a particular dive profile, decompression tables for more general use, or be implemented in dive computer software.

Choice of tables or algorithms edit

During the 1980s the US recreational diving community tended to move away from the US Navy tables to a range of tables published by other organisations, including several of the diver certification agencies (BSAC, NAUI, PADI).[4]

Depending on the table or computer chosen the range of no-decompression limits at a given depth on air can vary considerably, for example for 100 fsw (30 msw) the no stop limit varies from 25 to 8 minutes. It is not possible to discriminate between "right" and "wrong" options, but it is considered correct to say that the risk of developing DCS is greater for the longer exposures and less for the shorter exposures.[4]

The choice of tables for professional diving use is generally made by the organisation employing the divers. For recreational training it is usually prescribed by the certifying agency, but for recreational purposes the diver is generally free to make use of any of the published tables, and for that matter, to modify them to suit himself or herself.[4]

Decompression tables edit

 
BSAC nitrox decompression tables
 
The PADI Nitrox tables are laid out in what has become a common format for no-stop recreational tables

Dive tables or decompression tables are tabulated data, often in the form of printed cards or booklets, that allow divers to determine a decompression schedule for a given dive profile and breathing gas.[5]

With dive tables, it is generally assumed that the dive profile is a square dive, meaning that the diver descends to maximum depth immediately and stays at the same depth until resurfacing (approximating a rectangular outline when drawn in a coordinate system where one axis is depth and the other is duration).[6] Some dive tables also assume physical condition or acceptance of a specific level of risk from the diver.[7] Some recreational tables only provide for no-stop dives at sea level sites,[5] but the more complete tables can take into account staged decompression dives and dives performed at altitude.[6]

Commonly used decompression tables edit

Other published tables edit

Recreational Dive Planner edit

 
The PADI recreational dive planner, in "Wheel" format.

The Recreational Dive Planner (or RDP) is a set of devices marketed by PADI with which no-stop time underwater can be calculated.[21] The RDP was developed by DSAT and was the first dive table developed exclusively for recreational, no stop diving.[15] There are four types of RDPs: the original table version first introduced in 1988, The Wheel version, the original electronic version or eRDP introduced in 2005 and the latest electronic multi-level version or eRDPML introduced in 2008.[22]

The low price and convenience of many modern dive computers mean that many recreational divers only use tables such as the RDP for a short time during training before moving on to use a diving computer.[23]

Decompression software edit

Decompression software such as Departure, DecoPlanner, Ultimate Planner, Z-Planner, V-Planner and GAP are available, which simulate the decompression requirements of different dive profiles with different gas mixtures using decompression algorithms.[24][25][26][27]

Decompression software can be used to generate tables or schedules matched to a diver's planned dive profile and breathing gas mixtures. The usual procedure is to generate schedules for the intended profile and for the most likely contingency profiles, such as slightly greater depth, delayed ascent and early ascent. Sometimes an emergency minimum decompression schedule and a more conservative schedule will be generated to allow the diver further options.[28]

Decompression software is available based on:

and variations of these

V-Planner runs the variable permeability model, developed by D.E. Yount and others in 2000, and allows the choice of VPM-B and VPM-B/E, with six conservatism levels (baseline plus five incrementally more conservative ones).[29] GAP allows the user to choose between a multitude of Bühlmann-based algorithms and the full reduced gradient bubble model, developed by Bruce Wienke in 2001, in its five conservatism levels (baseline, two incrementally more liberal and two incrementally more conservative).[29]

Personal decompression computers edit

 
HSE Explorer Trimix and rebreather dive computer. Suunto Mosquito with aftermarket strap and iDive DAN recreational dive computers

The personal decompression computer, or dive computer, is a small computer designed to be worn by a diver during a dive, with a pressure sensor and an electronic timer mounted in a waterproof and pressure resistant housing and which has been programmed to model the inert gas loading of the diver's tissues in real time during a dive.[30] Most are wrist mounted, but a few are mounted in a console with the submersible pressure gauge and possibly other instruments. A display allows the diver to see critical data during the dive, including the maximum and current depth, duration of the dive, and decompression data including the remaining no decompression limit calculated in real time for the diver throughout the dive. Other data such as water temperature and cylinder pressure are also sometimes displayed. The dive computer has the advantages of monitoring the actual dive, as opposed to the planned dive, and does not assume on a "square profile" – it dynamically calculates the real profile of pressure exposure in real time, and keeps track of residual gas loading for each tissue used in the algorithm.[31] Dive computers also provide a measure of safety for divers who accidentally dive a different profile to that originally planned. If the diver exceeds a no-decompression limit, decompression additional to the ascent rate will be necessary. Most dive computers will provide the necessary decompression information for acceptably safe ascent in the event that the no-decompression limits are exceeded.[31]

The use of computers to manage recreational dive decompression is becoming the standard and their use is also common in occupational scientific diving. Their value in surface supplied commercial diving is more restricted, but they can usefully serve as a dive profile recorder.[32]

Decompression using a personal decompression computer edit

The personal decompression computer provides a real time modelling of the inert gas load on the diver according to the decompression algorithm programmed into the computer by the manufacturer, with possible personal adjustments for conservatism and altitude set by the user. In all cases the computer monitors the depth and elapsed time of the dive, and many allow user input specifying the gas mixture.[31]

Most computers require the diver to specify the mixture before the dive, but some allow the choice of mixture to be changed during the dive, which allows for the use of gas switching for accelerated decompression. A third category, mostly used by closed circuit rebreather divers, monitors the partial pressure of oxygen in the breathing mix using a remote oxygen sensor, but requires diver intervention to specify the inert gas constituents and ratio of the mix in use.[31]

The computer retains the diver's pressure exposure history, and continuously updates the calculated tissue loads on the surface, so the current tissue loading should always be correct according to the algorithm, though it is possible to provide the computer with misleading input conditions, which can nullify its reliability.[31]

This ability to provide real-time tissue loading data allows the computer to indicate the diver's current decompression obligation, and to update it for any permissible profile change, so the diver with a decompression ceiling does not have to decompress at any specific depth provided the ceiling is not violated, though the decompression rate will be affected by the depth. As a result, the diver can make a slower ascent than would be called for by a decompression schedule computed by the identical algorithm, as may suit the circumstances, and will be credited for gas elimination during the slower ascent, and penalised if necessary for additional ingassing for those tissues affected. This provides the diver with an unprecedented flexibility of dive profile while remaining within the safety envelope of the algorithm in use.[31]

Ratio decompression edit

Ratio decompression (usually referred to in abbreviated form as ratio deco) is a technique for calculating decompression schedules for scuba divers engaged in deep diving without using dive tables, decompression software or a dive computer. It is generally taught as part of the "DIR" philosophy of diving promoted by organisations such Global Underwater Explorers (GUE) and Unified Team Diving (UTD) at the advanced technical diving level. It is designed for decompression diving executed deeper than standard recreational diving depth limits using trimix as a "bottom mix" breathing gas.[33]

It is largely an empirical procedure, and has a reasonable safety record within the scope of its intended application. Advantages are reduced overall decompression time and for some versions, easy estimation of decompression by the use of a simple rule-based procedure which can be done underwater by the diver. It requires the use of specific gas mixtures for given depth ranges. The advantages claimed are flexibility in that if the depth is not known accurately, the schedule can be adjusted during the dive to allow for the actual depth, and that it allows deep dives without the use of an expensive trimix dive computer.[33]

Limitations include that a consistent set of gases must be used which match the specific ratio model, and the specific ratio will only be relevant to a limited range of depths. As the parameters move away from the base conditions, conservatism will diverge, and the probability of symptomatic bubble formation will become more unpredictable. There is also the requirement for the diver to do mental arithmetic at depth to calculate the parameters of a safety-critical operation. This may be complicated by adverse circumstances or an emergency situation.[33]

Controlling depth and ascent rate edit

A critical aspect of successful decompression is that the depth and ascent rate of the diver must be monitored and sufficiently accurately controlled. Practical in-water decompression requires a reasonable tolerance for variation in depth and rate of ascent, but unless the decompression is being monitored in real time by a decompression computer, any deviations from the nominal profile will affect the risk. Several items of equipment are used to assist in facilitating accurate adherence to the planned profile, by allowing the diver to more easily control depth and ascent rate, or to transfer this control to specialist personnel at the surface.[34]

Shot lines edit

 
Divers ascending and decompressing using a shotline

A shot line is a rope between a float at the surface, and a sufficiently heavy weight holding the rope approximately vertical. The shot line float should be sufficiently buoyant to support the weight of all divers that are likely to be using it at the same time. As divers are seldom weighted to be very negatively buoyant, a positive buoyancy of 50 kg is considered adequate by some authorities for general commercial use.[35] Recreational divers are free to choose lesser buoyancy at their own risk. The shot weight should be sufficient to prevent a diver from lifting it from the bottom by over-inflation of the buoyancy compensator or dry suit, but not sufficient to sink the float if the slack on the line is all taken up. Various configurations of shot line are used to control the amount of slack.[36]

The diver ascends along the shotline, and may use it purely as a visual reference, or can hold on to it to positively control depth, or can climb up it hand over hand. A Jonline may be used to fasten a diver to an anchor line or shot line during a decompression stop.[36]

Shot line configurations:

Jonlines edit

 
Webbing jon-line with bolt snaps, folded and bundled using velcro tabs
 
Webbing jon-line with bolt snaps

A Jonline is a short line used by scuba divers to fasten themselves to something. The original purpose was to fasten a diver to a shot line during decompression stops in current. The line is typically around 1 m (3 feet) long and equipped with a clip at each end. One clip is fastened to the diver's harness, and the other is used to fasten the line to the shot line or anchor line. In current this relieves the diver from holding on to the line during the decompression stop, and the horizontal length of the line will absorb some or all of the vertical movement of the shot line or anchor line due to wave action.

The jonline is named after Jon Hulbert, who is credited with its invention.[38]

A jonline can also be used to tether the diver's equipment to the dive boat before or after the dive. This helps the diver to put on or take off the equipment while in the water without drifting away from the boat. It is similar to a buddy line, which is used to tether two divers together during a dive.

Decompression trapezes edit

 
Scuba diver decompressing on decompression trapeze using surface supplied gas
 
Divers decompressing at the trapeze which was lowered into the water when the second DSMB was deployed as a signal

A decompression trapeze or decompression bar is a device used in recreational diving and technical diving to make decompression stops more comfortable and more secure and provide the divers' surface cover with a visual reference for the divers' position.[36]

It consists of a horizontal bar or bars suspended at the depth of intended decompression stops by buoys. The bars are of sufficient weight and the buoys of sufficient buoyancy that the trapeze will not easily change depth in turbulent water or if the divers experience buoyancy control problems.[36][39]

Trapezes are often used with diving shots. When diving in tidal waters at the end of slack water, the trapeze may be released from the diving shot to drift in the current as the divers make their decompression stops. A decompression trapeze may also be deployed in response to a signal from the divers, in which case some care must be taken not to hit a diver while lowering the bar.

Downline edit

A downline is a rope leading from the surface down to the underwater workplace. It allows a commercial diver to travel directly to and from the job site and to control rate of descent and ascent in the same way as using a shotline. Also sometimes called a jackstay.[40]

A downline used for open ocean diving is much the same as a shotline, but does not reach all the way to the bottom. An open-ocean downline is weighted at the bottom, and attached to a substantial float at the surface, which may be tethered to the boat. It may be marked at intervals by knots or loops, and may be attached to decompression trapeze system. In some cases a sea anchor may be used to limit wind drift, particularly if attached to a boat with significant windage.[41]

Upline edit

Also known as a Jersey upline, an upline is a line deployed by the diver, and fixed to the bottom, usually on a wreck, to serve as a position and depth control during offshore ascents in moderate currents, where the diver wants to prevent excessive drift during decompression. The bio-degradable natural fibre line is carried on a spool and deployed connected to an inflatable decompression buoy or lift bag at the end of the dive, and the bottom end tied off to the wreck. After completing decompression and surfacing, the diver cuts the line free at the buoy, and the line sinks and naturally decomposes over a few months.[citation needed]

Positive buoyancy emergency ascent upline edit

A similar application is used for emergency ascent when the diver is unable to establish neutral to negative buoyancy, or when this is expected to occur at some point during the ascent, and the diver has a decompression obligation, as when ballast weights have been lost, but the diver is still at the bottom and has a ratchet reel with sufficient line. In this case the reel line is tied off to a sufficiently heavy or fixed object on the bottom, and the diver ascends at the appropriate rate paying out line under tension, and making the required decompression stops. It will generally be necessary to cut the line after surfacing, unless another diver is available to go down to release it. This is a required skill for the CMAS Self-Rescue Diver certification.[42]

Surface marker buoy and delayed surface marker buoy edit

 
Four stages of scuba ascent with delayed surface marker buoy: Preparation, deployment, ascent, decompression stop
 
Diver deploying a DSMB

A surface marker buoy (SMB) with a reel and line is often used by a dive leader to allow the boat to monitor progress of the dive group. This can provide the operator with a positive control of depth, by remaining slightly negative and using the buoyancy of the float to support this slight over-weighting. This allows the line to be kept under slight tension which reduces the risk of entanglement. The reel or spool used to store and roll up the line usually has slightly negative buoyancy, so that if released it will hang down and not float away.[43][44]

A delayed or deployable surface marker buoy (DSMB), also known a decompression buoy, is a soft inflatable tube that is attached to a reel or spool line at one end, and is inflated by the diver under water and released to float to the surface, running out the line as it ascends. This provides information to the surface that the diver is about to ascend, and from where. This equipment is commonly used by recreational and technical divers, and requires a certain level of skill to operate safely. Once deployed, it can be used for the same purposes as the standard surface marker and reel, and in the same way, but they are mostly used to signal the boat that the diver has started ascent, as a means of accurately controlling ascent rate and stop depth, or to indicate a problem in technical diving.[44][45][46][47]

Decompression station edit

A decompression station is a place set up to facilitate the planned decompression for a dive team, and to help a group of divers stay together during long decompression. A simple example would be a decompression trapeze system linked to the shotline or the dive boat. The decompression station may also have backup equipment stored in case of emergency, and provides a visual depth reference, and a physical aid to maintaining a constant depth. More complex systems may include a small underwater habitat.[45]

In cases where a decompression habitat is used, there may be less exposure to cold water if the divers can partly or completely exit the water into an air-filled space, equivalent to an open diving bell. A habitat type decompression station can be an advantage when doing long decompressions on high oxygen partial pressure as the risks associated with oxygen toxicity are reduced, and it is easier for safety divers to assist. The term decompression station is associated with technical diving, professional divers would generally use a wet or dry diving bell for the same purpose.[45]

Diving stages and wet bells edit

 
Diving stage

A diving stage, sometimes known as a diving basket, is a platform on which one or two divers stand which is hoisted into the water, lowered to the workplace or the bottom, and then hoisted up again to return the diver to the surface and out of the water. This equipment is almost exclusively used by surface supplied professional divers, as it requires fairly complex lifting equipment. A diving stage allows the surface team to conveniently manage a diver's decompression as it can be hoisted at a controlled rate and stopped at the correct depth for decompression stops, and allows the divers to rest during the ascent. It also allows the divers to be relatively safely and conveniently lifted out of the water and returned to the deck or quayside.[48][49]

A wet bell, or open bell, is similar to a diving stage in concept, but has an air space, open to the water at the bottom in which the divers, or at least their heads, can shelter during ascent and descent. A wet bell provides more comfort and control than a stage and allows for longer time in the water. Wet bells are used for air and mixed gas, and divers can decompress using oxygen from a mask at 12 m.[50] A bell stage is an open platform used with a closed bell to keep the bell from getting too close to the bottom, which could make it difficult or impossible for the divers to get in or out through the bottom lock. It may be connected to the bell or to the clump weight.

The launch and recovery system (LARS) is the equipment used to deploy and recover a stage or diving bell. The sane name is applied to the equipment used to launch and recover small submersibles and ROVs.[48]

Providing gases to accelerate decompression edit

 
Technical divers preparing for a mixed-gas decompression dive. Note the backplate and wing setup with side mounted stage tanks containing EAN50 (left side) and pure oxygen (right side).

Reducing the partial pressure of the inert gas component of the breathing mixture will accelerate decompression as the concentration gradient will be greater for a given depth. This is achieved by increasing the fraction of oxygen in the breathing gas used, whereas substitution of a different inert gas will not produce the desired effect. Substitution may introduce counter-diffusion complications, owing to differing rates of diffusion of the inert gases, which can lead to a net gain in total dissolved gas tension in a tissue. This can lead to bubble formation and growth, with decompression sickness as a consequence. Partial pressure of oxygen is usually limited to 1.6 bar during in water decompression for scuba divers, but can be up to 1.9 bar in-water and 2.2 bar in the chamber when using the US Navy tables for surface decompression,[8] and up to 2.8 bar for therapeutic decompression.[51]

Stage cylinders edit

Open circuit scuba divers by definition are independent of surface supply, and must take any gas mixture with them that is to be used on the dive. However, if they are confident of returning by a specific route, the decompression gas may be stored at appropriate places on that route. The cylinders used for this purpose are called stage cylinders, and they are usually provided with a standard regulator and a submersible pressure gauge, and are usually left at the stop with the regulator pressurised, but the cylinder valve turned off to minimise the risk of gas loss. Similar cylinders are carried by the divers when the route back is not secure. They are commonly mounted as sling cylinders, clipped to D-rings at the sides of the diver's harness.[52]

Scuba divers take great care to avoid breathing oxygen enriched "deco gas" at great depths because of the high risk of oxygen toxicity. To prevent this happening, cylinders containing oxygen-rich gases must always be positively identifiable. One way of doing this is by marking them with their maximum operating depth as clearly as possible.[52] Other safety precautions may include using different coloured regulator housing, flavoured mouthpieces, or simply placing a rubber band vertically across the mouthpiece as an alert.[53]

Surface panel gas switching edit

Surface supplied divers may be supplied with a gas mixture suitable for accelerated decompression by connecting a supply to the surface gas panel and connecting it through the valve system to the divers. This allows accelerated decompression, usually on oxygen, which can be used to a maximum depth of 20 ft (6 m) in water for scuba and 30 ft (9 m) on surface supply.[8] Surface supplied heliox bounce divers will be provided with mixtures suitable for their current depth, and the mixture may be changed several times during descent and ascent from great depths.[54]

Continuously variable mixture in closed circuit rebreathers edit

 
Rebreather diver with bailout and decompression cylinders

Closed circuit rebreathers are usually controlled to provide a fairly constant partial pressure of oxygen during the dive (set point), and may be reset to a richer mix (higher partial pressure of oxygen) for decompression. The effect is to keep the partial pressure of inert gases as low as safely practicable throughout the dive. This minimises the absorption of inert gas in the first place, and accelerates the elimination of the inert gases during ascent.[55]

Surface decompression equipment edit

Deck decompression chambers edit

 
A basic deck decompression chamber

A deck decompression chamber (DDC), or double-lock chamber is a two compartment pressure vessel for human occupation which has sufficient space in the main chamber for two or more occupants, and a forechamber which can allow a person to be pressurised or decompressed while the main chamber remains under constant pressure. This allows an attendant to be locked in or out during treatment of the occupant(s) of the main chamber. There is usually also a medical lock, which serves a similar function but is much smaller. This is used to transfer medical material, food and specimens into and out of the main chamber while it is under pressure. Most deck decompression chambers are fitted with built-in breathing systems (BIBS), which supply an alternative breathing gas to the occupants (usually oxygen), and discharge the exhaled gas outside the chamber, so the chamber gas is not excessively enriched by oxygen, which would cause an unacceptable fire hazard, and require frequent flushing with chamber gas (usually air).[56]

A deck decompression chamber is intended for surface decompression and emergency hyperbaric treatment of divers, but can be used for other hyperbaric treatment under the appropriate supervision of hyperbaric medical personnel.[56]

Portable or mobile one and two occupant single compartment chambers are not generally intended for routine surface decompression, but may be used in an emergency.[56]

Dry bells and Saturation systems edit

 
Personnel transfer capsule, closed bell, or dry bell.
 
Part of a saturation system: On the left is a part of the living space with a medical lock in the foreground. To the right is the wet-room, on the top of which there is a flange to which the dry bell is bolted for transfer of the divers between the hyperbaric habitat and the bell.

A "Saturation System" or "Saturation spread" typically includes a living chamber, transfer chamber and submersible decompression chamber, which is commonly referred to in commercial diving and military diving as the diving bell,[57] PTC (Personnel Transfer Capsule) or SDC (Submersible Decompression Chamber).[58] The system can be permanently installed on a ship or ocean platform, but is more commonly capable of being dismantled and moved from one vessel to another by crane. The entire system is managed from a control room, commonly referred to as the "van", where depth, chamber atmosphere and other system parameters are monitored and controlled. The diving bell is the elevator or lift that transfers divers from the system to the work site. Typically, it is mated to the system utilizing a removable clamp and is separated from the system tankage bulkhead by a trunking space, a kind of short tunnel, through which the divers transfer to and from the bell. At the completion of work or a mission, the saturation diving team is decompressed gradually back to atmospheric pressure by the slow venting of system pressure, at rates of about of 15 to 30 msw (50 to 100 fsw) per day, (schedules vary). Thus the process involves only one ascent, thereby mitigating the time-consuming and comparatively risky process of multiple decompressions normally associated with non-saturation ("bounce diving") operations.[59] The chamber gas mixture is typically controlled to maintain a nominally constant partial pressure of oxygen of between 0.3 and 0.5 bar during most of the decompression (0.44 to 0.48 bar on US Navy schedule), which is below the upper limit for long term exposure.[60] NOAA has used rather different saturation decompression schedules for relatively shallow (less than 100 fsw) air and nitrox saturation dives, which use oxygen breathing when pressure is reduced to less than 55 fsw.[61]

The divers use surface supplied umbilical diving equipment, using a breathing gas suitable for the depth and pressure, such as helium and oxygen mixtures, stored in large capacity, high pressure cylinders.[59] The gas supplies are plumbed to a control panel in the control room, where they are routed to supply the system components. The bell is fed via a large, multi-part umbilical that supplies breathing gas, electrical power, cable communications and hot water, and may return exhaled gas to the surface for recycling. The bell also is fitted with externally-mounted breathing gas storage cylinders for emergency use. The divers are supplied from the bell through personal excursion umbilicals.[58]

A hyperbaric lifeboat or hyperbaric rescue unit may be provided for emergency evacuation of saturation divers from a saturation system. This would be used if the platform is at immediate risk due to fire or sinking, and allows the divers under saturation to get clear of the immediate danger. A hyperbaric lifeboat may be self-propelled and can be operated by unpressurised crew while the occupants are under pressure. It must be self-sufficient for several days at sea, in case of a delay in rescue due to sea conditions. The crew would normally start decompression as soon as safely possible after launching.[62]

A dry bell may also be used for bounce dives to great depths, and then used as the decompression chamber during the ascent and later on board the support vessel. In this case it is not always necessary to transfer into a deck chamber, as the bell is quite capable of performing this function, though it would be relatively cramped, as a bell is usually as small as conveniently possible to minimise weight for deployment.[59]

See also edit

References edit

  1. ^ Van Liew, Hugh D; Bishop, B; Walder, P; Rahn, H (1965). "Effects of compression on composition and absorption of tissue gas pockets". Journal of Applied Physiology. 20 (5): 927–33. doi:10.1152/jappl.1965.20.5.927. ISSN 0021-8987. OCLC 11603017. PMID 5837620.
  2. ^ Staff (13 April 2010). . Sport Diver (online magazine). PADI. Archived from the original on 6 March 2016. Retrieved 3 March 2016.
  3. ^ US Navy Diving Manual Revision 6, Chpt. 8 section 5
  4. ^ a b c Huggins 1992, Introduction page 1
  5. ^ a b Huggins 1992, Chpt. 4 pages 1–18
  6. ^ a b US Navy Diving Manual Revision 6, chpt. 9 sect. 8 The air decompression table
  7. ^ a b Huggins 1992, Chpt. 4 page 15
  8. ^ a b c US Navy Diving Manual Revision 6, Chpt. 9
  9. ^ Bühlmann Albert A. (1984). Decompression–Decompression Sickness. Berlin, New York: Springer-Verlag. ISBN 0-387-13308-9.
  10. ^ Bühlmann, Albert A (1995). Tauchmedizin (in German). Berlin: Springer-Verlag. ISBN 3-540-55581-1.
  11. ^ Bühlmann, Albert A. (1992). Tauchmedizin: Barotrauma Gasembolie Dekompression Dekompressionskrankheit (in German). Berlin: Springer-Verlag. ISBN 3-540-55581-1.
  12. ^ "British RNPL Decompression tables" (PDF). Royal Naval Physiological Laboratory. 1972. Retrieved 2 March 2016.
  13. ^ Adkisson, G (1991). "The BS-AC '88 decompression tables". South Pacific Underwater Medicine Society Journal. 21 (1). Archived from the original on 15 April 2013. Retrieved 10 January 2012.{{cite journal}}: CS1 maint: unfit URL (link)
  14. ^ Powell 2008, "Other decompression models"; page 203
  15. ^ a b Hamilton, R.W. Jr; Rogers, R.E.; Powell, M.R. (1994). (Report). Tarrytown, NY: Diving Science & Technology Corp. Archived from the original on 7 August 2009. Retrieved 15 June 2008.{{cite report}}: CS1 maint: unfit URL (link)
  16. ^ Powell 2008, "Other decompression models"; page 209–13
  17. ^ Nishi, R.Y.; Tikuisis, P. (December 1996). "Current Trends in Decompression Development: Statistics and Data Analysis". Defense Technical Information Center.
  18. ^ Trucco, Jean-Noël; Biard, Jef; Redureau, Jean-Yves; Fauvel, Yvon (3 May 1999). "Table Marine National 90 (MN90): Version du 03/05/1999" (PDF). Comité interrégional Bretagne & Pays de la Loire; Commission Technique Régionale. (in French). F.F.E.S.S.M. Retrieved 23 January 2017.
  19. ^ a b c d Huggins 1992, Chpt. 4 page 11
  20. ^ Huggins 1992, Chpt. 4 page 10
  21. ^ Duis, D. (1991). "Using the Recreational Diver Planner for multi-level diving". In: Hans-Jurgen, K; Harper Jr, DE (Eds.) International Pacifica Scientific Diving ... 1991. Proceedings of the American Academy of Underwater Sciences Eleventh Annual Scientific Diving Symposium held 25–30 September 1991. University of Hawaii, Honolulu, Hawaii. Archived from the original on 15 April 2013. Retrieved 17 October 2011.{{cite journal}}: CS1 maint: unfit URL (link)
  22. ^ Staff (2008). "Introducing the eRDPML". Big Blue Technical Diving News and Events: Archive for August 4, 2008. Big Blue Technical Diving. Retrieved 7 March 2016.
  23. ^ Huggins, K.E. "Performance of dive computers exposed to profiles with known human subject results" (PDF). Catalina Hyperbaric Chamber, Wrigley Marine Science Center University of Southern California. Retrieved 6 March 2016.
  24. ^ "Departure – Dive Planning and Decompression software". Diverssupport.com. Retrieved 17 July 2012.
  25. ^ "DecoPlanner, decompression simulation software". Gue.com. Retrieved 17 July 2012.
  26. ^ Ultimate Planner – decompression planning software tool http://www.techdivingmag.com/ultimateplanner.html
  27. ^ "GAP-software, decompression simulation software". Gap-software.com. 10 February 2008. Retrieved 17 July 2012.
  28. ^ Beresford, M.; Southwood, P. (2006). CMAS-ISA Normoxic Trimix Manual (4th ed.). Pretoria, South Africa: CMAS Instructors South Africa.
  29. ^ a b Blogg, S.L.; Lang, M.A.; Møllerløkken, A., eds. (2012). "Proceedings of the Validation of Dive Computers Workshop". European Underwater and Baromedical Society Symposium, August 24, 2011. Gdansk. Trondheim: Norwegian University of Science and Technology. Archived from the original on 15 April 2013. Retrieved 7 March 2013.{{cite journal}}: CS1 maint: unfit URL (link)
  30. ^ Lang, M.A.; Hamilton, Jr R.W. (1989). Proceedings of the AAUS Dive Computer Workshop. United States: USC Catalina Marine Science Center. p. 231. Archived from the original on 7 July 2012. Retrieved 7 August 2008.{{cite book}}: CS1 maint: unfit URL (link)
  31. ^ a b c d e f Møllerløkken, Andreas (24 August 2011). Blogg, S. Lesley; Lang, Michael A.; Møllerløkken, Andreas (eds.). "Proceedings of Validation of Dive Computers Workshop". Gdansk, Poland: European Underwater and Baromedical Society. Archived from the original on 15 April 2013. Retrieved 3 March 2016.{{cite web}}: CS1 maint: unfit URL (link)
  32. ^ Azzopardi, E.; Sayer, M.D.J. (2010). "A review of the technical specifications of 47 models of diving decompression computer". International Journal of the Society for Underwater Technology. Society for Underwater Technology. 29 (2): 63–70. doi:10.3723/ut.29.063.
  33. ^ a b c Powell 2008, "Other decompression models"; pages 213–217
  34. ^ US Navy Diving Manual Revision 6, Chpt. 9 section 11 Variations in rate of ascent
  35. ^ Department of Labour Diving Council (11 January 2002). "Diving regulations 2001 of the Occupational Health and Safety Act 85 of 1993". Government Gazette, Republic of South Africa. Vol. 438, no. 2291. Pretoria: Government Printer.
  36. ^ a b c d e f g Boan, Charlotte (2014). "How to deploy a shotline". Dive magazine archive. Syon publishing. Retrieved 3 March 2016.
  37. ^ Edmonds, Carl; Bennett, Michael; Lippmann, John; Mitchell, Simon (2 July 2015). "Equipment for recreational diving". Diving and Subaquatic Medicine, Fifth Edition (5, illustrated, revised ed.). CRC Press. p. 45. ISBN 978-1-4822-6013-7. Retrieved 7 March 2016.
  38. ^ Gentile, Gary (1998). The Technical Diving Handbook. Gary Gentile Productions. ISBN 1-883056-05-5.
  39. ^ "Technical Issues". Newry & Mourne Sub Aqua Club. Retrieved 28 August 2009.
  40. ^ Barsky, Steven M.; Christensen, Robert W. (2004). The Simple Guide to Commercial Diving (Illustrated ed.). Hammerhead Press. p. 92. ISBN 978-0-9674305-4-6.
  41. ^ Warlaumont, John (October 1991). "10.6 Open ocean diving". NOAA Diving Manual: Diving for Science and Technology (Illustrated ed.). DIANE Publishing. pp. 10–14 to 10–15. ISBN 978-1-56806-231-0. Retrieved 17 March 2017.
  42. ^ Staff (4 March 2014). "CMAS Self-Rescue Diver". Standard Number: 2.B.31 / BOD no 181 ( 04-18-2013 ). CMAS. Retrieved 13 April 2017.
  43. ^ Staff (2005–2016). "Surface Marker Buoys (SMBs)". Scuba Doctor website. Melbourne: The Scuba Doctor Australia. Retrieved 7 March 2016.
  44. ^ a b Staff. "Recommendations Concerning the Use of Surface Marker Buoys" (PDF). British Diving Safety Group. Retrieved 7 March 2016.
  45. ^ a b c Gurr, Kevin (August 2008). "13: Operational Safety". In Mount, Tom; Dituri, Joseph (eds.). Exploration and Mixed Gas Diving Encyclopedia (1st ed.). Miami Shores, Florida: International Association of Nitrox Divers. pp. 165–180. ISBN 978-0-915539-10-9.
  46. ^ Staff (2015). . BSAC Safe Diving. British Sub-Aqua Club. p. 18. Archived from the original on 3 April 2012. Retrieved 7 March 2016.
  47. ^ Nawrocky, Pete (2014). "We're Over Here!". Alert Diver online, Spring 2014. Divers Alert Network. Retrieved 7 March 2016.
  48. ^ a b Staff. "Diving Launch And Recovery Systems". Commercial Diving Equipment. Submarine Manufacturing & Products Ltd. Retrieved 7 March 2016.
  49. ^ Staff. "Pommec 2 diver launch and recovery system with diving basket" (PDF). Technical Diving Equipment. Pommec BV. Retrieved 7 March 2016.
  50. ^ Imbert, Jean Pierre (February 2006). Lang; Smith (eds.). "Commercial Diving: 90m Operational Aspects" (PDF). Advanced Scientific Diving Workshop. Smithsonian Institution. Retrieved 30 June 2012.
  51. ^ U.S. Navy Department, 1975. U.S. Navy Diving Manual, Volume 1, Change 1. U.S. Government Printing Office, Washington, D.C. NAVSEA 099-LP-001-9010
  52. ^ a b Jablonski, Jarrod (2006). "Details of DIR Equipment Configuration". Doing it Right: The Fundamentals of Better Diving. High Springs, Florida: Global Underwater Explorers. p. 113. ISBN 0-9713267-0-3.
  53. ^ Gentile, Gary (July 1988). Advanced Wreck Diving Guide (3rd ed.). Cornell Maritime Press. p. 60. ISBN 978-0-87033-380-4.
  54. ^ US Navy Diving Manual Revision 6, Chpt. 14 page 2 "Gas nixtures"
  55. ^ US Navy Diving Manual Revision 6, Chpt. 17
  56. ^ a b c US Navy Diving Manual Revision 6, Chpt. 21 Recompression chamber operation
  57. ^ Bevan, J. (1999). . South Pacific Underwater Medicine Society Journal. 29 (1). ISSN 0813-1988. OCLC 16986801. Archived from the original on 11 February 2009. Retrieved 25 April 2008.{{cite journal}}: CS1 maint: unfit URL (link)
  58. ^ a b US Navy Diving Manual Revision 6, Chpt. 15 Saturation Diving
  59. ^ a b c Beyerstein, G. (2006). Lang, M.A.; Smith, N.E. (eds.). . Proceedings of Advanced Scientific Diving Workshop. Smithsonian Institution, Washington, DC. Archived from the original on 21 February 2009. Retrieved 12 April 2010.{{cite conference}}: CS1 maint: unfit URL (link)
  60. ^ US Navy Diving Manual Revision 6, Chpt. 15 sect. 23 pp 33 seq.
  61. ^ James W. Miller, ed. (1979). "12.6 Decompression after an air or nitrogen-oxygen saturation dive". NOAA Diving Manual (2nd ed.). United States Department of Commerce.
  62. ^ Staff (May 2013). "Guidance on Hyperbaric Evacuation Systems" (PDF). Guidance on Hyperbaric Evacuation Systems IMCA D 052 May 2013. International Marine Contractors' Association. Retrieved 6 March 2016.

Sources edit

  • Huggins, Karl E. (1992). "Dynamics of decompression workshop". Course Taught at the University of Michigan.
  • Powell, Mark (2008). Deco for Divers. Southend-on-Sea: Aquapress. ISBN 978-1-905492-07-7.
  • US Navy (2006). US Navy Diving Manual, 6th revision. United States: US Naval Sea Systems Command.
  • US Navy (2018). US Navy Diving Manual, 7th revision Ch A. United States: US Naval Sea Systems Command.

External links edit

  •   Media related to Decompression equipment at Wikimedia Commons

decompression, equipment, there, several, categories, decompression, equipment, used, help, divers, decompress, which, process, required, allow, divers, return, surface, safely, after, spending, time, underwater, higher, ambient, pressures, surface, supplied, . There are several categories of decompression equipment used to help divers decompress which is the process required to allow divers to return to the surface safely after spending time underwater at higher ambient pressures Decompression equipmentSurface supplied diver on diving stageUsesEquipment used by divers to facilitate decompressionRelated itemsDive computer Decompression practice Diving bell Diving chamberDecompression obligation for a given dive profile must be calculated and monitored to ensure that the risk of decompression sickness is controlled Some equipment is specifically for these functions both during planning before the dive and during the dive Other equipment is used to mark the underwater position of the diver as a position reference in low visibility or currents or to assist the diver s ascent and control the depth Decompression may be shortened accelerated by breathing an oxygen rich decompression gas such as a nitrox blend or pure oxygen The high partial pressure of oxygen in such decompression mixes produces the effect known as the oxygen window 1 This decompression gas is often carried by scuba divers in side slung cylinders Cave divers who can only return by a single route can leave decompression gas cylinders attached to the guideline stage or drop cylinders at the points where they will be used 2 Surface supplied divers will have the composition of the breathing gas controlled at the gas panel 3 Divers with long decompression obligations may be decompressed inside gas filled hyperbaric chambers in the water or at the surface and in the extreme case saturation divers are only decompressed at the end of a project contract or tour of duty that may be several weeks long Contents 1 Planning and monitoring decompression 1 1 Decompression algorithms 1 1 1 Choice of tables or algorithms 1 2 Decompression tables 1 2 1 Commonly used decompression tables 1 2 2 Other published tables 1 2 3 Recreational Dive Planner 1 3 Decompression software 1 4 Personal decompression computers 1 4 1 Decompression using a personal decompression computer 1 5 Ratio decompression 2 Controlling depth and ascent rate 2 1 Shot lines 2 1 1 Jonlines 2 1 2 Decompression trapezes 2 2 Downline 2 3 Upline 2 3 1 Positive buoyancy emergency ascent upline 2 4 Surface marker buoy and delayed surface marker buoy 2 5 Decompression station 2 6 Diving stages and wet bells 3 Providing gases to accelerate decompression 3 1 Stage cylinders 3 2 Surface panel gas switching 3 3 Continuously variable mixture in closed circuit rebreathers 4 Surface decompression equipment 4 1 Deck decompression chambers 4 2 Dry bells and Saturation systems 5 See also 6 References 6 1 Sources 7 External linksPlanning and monitoring decompression editEquipment for planning and monitoring decompression includes decompression tables depth gauges timers surface computer software and personal decompression computers There is a wide range of choice Decompression algorithms edit nbsp Inert gas tension in the tissue compartments during a decompression dive with gas switching to accelerate decompression as predicted by a decompression algorithmFurther information Buhlmann decompression algorithm Thalmann algorithm Reduced gradient bubble model and Varying Permeability Model A decompression algorithm is used to calculate the decompression stops needed for a particular dive profile to reduce the risk of decompression sickness occurring after surfacing at the end of a dive The algorithm can be used to generate decompression schedules for a particular dive profile decompression tables for more general use or be implemented in dive computer software Choice of tables or algorithms edit During the 1980s the US recreational diving community tended to move away from the US Navy tables to a range of tables published by other organisations including several of the diver certification agencies BSAC NAUI PADI 4 Depending on the table or computer chosen the range of no decompression limits at a given depth on air can vary considerably for example for 100 fsw 30 msw the no stop limit varies from 25 to 8 minutes It is not possible to discriminate between right and wrong options but it is considered correct to say that the risk of developing DCS is greater for the longer exposures and less for the shorter exposures 4 The choice of tables for professional diving use is generally made by the organisation employing the divers For recreational training it is usually prescribed by the certifying agency but for recreational purposes the diver is generally free to make use of any of the published tables and for that matter to modify them to suit himself or herself 4 Decompression tables edit nbsp BSAC nitrox decompression tables nbsp The PADI Nitrox tables are laid out in what has become a common format for no stop recreational tablesDive tables or decompression tables are tabulated data often in the form of printed cards or booklets that allow divers to determine a decompression schedule for a given dive profile and breathing gas 5 With dive tables it is generally assumed that the dive profile is a square dive meaning that the diver descends to maximum depth immediately and stays at the same depth until resurfacing approximating a rectangular outline when drawn in a coordinate system where one axis is depth and the other is duration 6 Some dive tables also assume physical condition or acceptance of a specific level of risk from the diver 7 Some recreational tables only provide for no stop dives at sea level sites 5 but the more complete tables can take into account staged decompression dives and dives performed at altitude 6 Commonly used decompression tables edit US Navy tables 8 Buhlmann tables 9 10 11 Royal Navy RNPL tables 12 13 BSAC 88 tables 14 PADI tables the recreational dive planner RDP and the wheel 15 DCIEM tables 16 17 French Navy MN90 tables 18 NAUI Dive tables 19 Other published tables edit Jeppesen 20 Huggins 19 German Buhlmann Hahn 19 Pandora tables 19 1 Risk 7 Recreational Dive Planner edit nbsp The PADI recreational dive planner in Wheel format Main article Recreational Dive Planner The Recreational Dive Planner or RDP is a set of devices marketed by PADI with which no stop time underwater can be calculated 21 The RDP was developed by DSAT and was the first dive table developed exclusively for recreational no stop diving 15 There are four types of RDPs the original table version first introduced in 1988 The Wheel version the original electronic version or eRDP introduced in 2005 and the latest electronic multi level version or eRDPML introduced in 2008 22 The low price and convenience of many modern dive computers mean that many recreational divers only use tables such as the RDP for a short time during training before moving on to use a diving computer 23 Decompression software edit Decompression software such as Departure DecoPlanner Ultimate Planner Z Planner V Planner and GAP are available which simulate the decompression requirements of different dive profiles with different gas mixtures using decompression algorithms 24 25 26 27 Decompression software can be used to generate tables or schedules matched to a diver s planned dive profile and breathing gas mixtures The usual procedure is to generate schedules for the intended profile and for the most likely contingency profiles such as slightly greater depth delayed ascent and early ascent Sometimes an emergency minimum decompression schedule and a more conservative schedule will be generated to allow the diver further options 28 Decompression software is available based on US Navy models both the dissolved phase and mixed phase models Buhlmann algorithm e g Z planner Reduced Gradient Bubble Model RGBM e g GAP Varying Permeability Model VPM e g V Plannerand variations of theseV Planner runs the variable permeability model developed by D E Yount and others in 2000 and allows the choice of VPM B and VPM B E with six conservatism levels baseline plus five incrementally more conservative ones 29 GAP allows the user to choose between a multitude of Buhlmann based algorithms and the full reduced gradient bubble model developed by Bruce Wienke in 2001 in its five conservatism levels baseline two incrementally more liberal and two incrementally more conservative 29 Personal decompression computers edit nbsp HSE Explorer Trimix and rebreather dive computer Suunto Mosquito with aftermarket strap and iDive DAN recreational dive computersFurther information Dive computer The personal decompression computer or dive computer is a small computer designed to be worn by a diver during a dive with a pressure sensor and an electronic timer mounted in a waterproof and pressure resistant housing and which has been programmed to model the inert gas loading of the diver s tissues in real time during a dive 30 Most are wrist mounted but a few are mounted in a console with the submersible pressure gauge and possibly other instruments A display allows the diver to see critical data during the dive including the maximum and current depth duration of the dive and decompression data including the remaining no decompression limit calculated in real time for the diver throughout the dive Other data such as water temperature and cylinder pressure are also sometimes displayed The dive computer has the advantages of monitoring the actual dive as opposed to the planned dive and does not assume on a square profile it dynamically calculates the real profile of pressure exposure in real time and keeps track of residual gas loading for each tissue used in the algorithm 31 Dive computers also provide a measure of safety for divers who accidentally dive a different profile to that originally planned If the diver exceeds a no decompression limit decompression additional to the ascent rate will be necessary Most dive computers will provide the necessary decompression information for acceptably safe ascent in the event that the no decompression limits are exceeded 31 The use of computers to manage recreational dive decompression is becoming the standard and their use is also common in occupational scientific diving Their value in surface supplied commercial diving is more restricted but they can usefully serve as a dive profile recorder 32 Decompression using a personal decompression computer edit The personal decompression computer provides a real time modelling of the inert gas load on the diver according to the decompression algorithm programmed into the computer by the manufacturer with possible personal adjustments for conservatism and altitude set by the user In all cases the computer monitors the depth and elapsed time of the dive and many allow user input specifying the gas mixture 31 Most computers require the diver to specify the mixture before the dive but some allow the choice of mixture to be changed during the dive which allows for the use of gas switching for accelerated decompression A third category mostly used by closed circuit rebreather divers monitors the partial pressure of oxygen in the breathing mix using a remote oxygen sensor but requires diver intervention to specify the inert gas constituents and ratio of the mix in use 31 The computer retains the diver s pressure exposure history and continuously updates the calculated tissue loads on the surface so the current tissue loading should always be correct according to the algorithm though it is possible to provide the computer with misleading input conditions which can nullify its reliability 31 This ability to provide real time tissue loading data allows the computer to indicate the diver s current decompression obligation and to update it for any permissible profile change so the diver with a decompression ceiling does not have to decompress at any specific depth provided the ceiling is not violated though the decompression rate will be affected by the depth As a result the diver can make a slower ascent than would be called for by a decompression schedule computed by the identical algorithm as may suit the circumstances and will be credited for gas elimination during the slower ascent and penalised if necessary for additional ingassing for those tissues affected This provides the diver with an unprecedented flexibility of dive profile while remaining within the safety envelope of the algorithm in use 31 Ratio decompression edit Main article Ratio decompression Ratio decompression usually referred to in abbreviated form as ratio deco is a technique for calculating decompression schedules for scuba divers engaged in deep diving without using dive tables decompression software or a dive computer It is generally taught as part of the DIR philosophy of diving promoted by organisations such Global Underwater Explorers GUE and Unified Team Diving UTD at the advanced technical diving level It is designed for decompression diving executed deeper than standard recreational diving depth limits using trimix as a bottom mix breathing gas 33 It is largely an empirical procedure and has a reasonable safety record within the scope of its intended application Advantages are reduced overall decompression time and for some versions easy estimation of decompression by the use of a simple rule based procedure which can be done underwater by the diver It requires the use of specific gas mixtures for given depth ranges The advantages claimed are flexibility in that if the depth is not known accurately the schedule can be adjusted during the dive to allow for the actual depth and that it allows deep dives without the use of an expensive trimix dive computer 33 Limitations include that a consistent set of gases must be used which match the specific ratio model and the specific ratio will only be relevant to a limited range of depths As the parameters move away from the base conditions conservatism will diverge and the probability of symptomatic bubble formation will become more unpredictable There is also the requirement for the diver to do mental arithmetic at depth to calculate the parameters of a safety critical operation This may be complicated by adverse circumstances or an emergency situation 33 Controlling depth and ascent rate editA critical aspect of successful decompression is that the depth and ascent rate of the diver must be monitored and sufficiently accurately controlled Practical in water decompression requires a reasonable tolerance for variation in depth and rate of ascent but unless the decompression is being monitored in real time by a decompression computer any deviations from the nominal profile will affect the risk Several items of equipment are used to assist in facilitating accurate adherence to the planned profile by allowing the diver to more easily control depth and ascent rate or to transfer this control to specialist personnel at the surface 34 Shot lines edit Main article Diving shot nbsp Divers ascending and decompressing using a shotlineA shot line is a rope between a float at the surface and a sufficiently heavy weight holding the rope approximately vertical The shot line float should be sufficiently buoyant to support the weight of all divers that are likely to be using it at the same time As divers are seldom weighted to be very negatively buoyant a positive buoyancy of 50 kg is considered adequate by some authorities for general commercial use 35 Recreational divers are free to choose lesser buoyancy at their own risk The shot weight should be sufficient to prevent a diver from lifting it from the bottom by over inflation of the buoyancy compensator or dry suit but not sufficient to sink the float if the slack on the line is all taken up Various configurations of shot line are used to control the amount of slack 36 The diver ascends along the shotline and may use it purely as a visual reference or can hold on to it to positively control depth or can climb up it hand over hand A Jonline may be used to fasten a diver to an anchor line or shot line during a decompression stop 36 Shot line configurations Basic shot line 36 Self tensioning arrangements Running weight 36 or top tensioned shotline Running float 36 or bottom tensioned shotline Lazy shot line 37 or lazy shotJonlines edit nbsp Webbing jon line with bolt snaps folded and bundled using velcro tabs nbsp Webbing jon line with bolt snapsA Jonline is a short line used by scuba divers to fasten themselves to something The original purpose was to fasten a diver to a shot line during decompression stops in current The line is typically around 1 m 3 feet long and equipped with a clip at each end One clip is fastened to the diver s harness and the other is used to fasten the line to the shot line or anchor line In current this relieves the diver from holding on to the line during the decompression stop and the horizontal length of the line will absorb some or all of the vertical movement of the shot line or anchor line due to wave action The jonline is named after Jon Hulbert who is credited with its invention 38 A jonline can also be used to tether the diver s equipment to the dive boat before or after the dive This helps the diver to put on or take off the equipment while in the water without drifting away from the boat It is similar to a buddy line which is used to tether two divers together during a dive Decompression trapezes edit nbsp Scuba diver decompressing on decompression trapeze using surface supplied gas nbsp Divers decompressing at the trapeze which was lowered into the water when the second DSMB was deployed as a signalA decompression trapeze or decompression bar is a device used in recreational diving and technical diving to make decompression stops more comfortable and more secure and provide the divers surface cover with a visual reference for the divers position 36 It consists of a horizontal bar or bars suspended at the depth of intended decompression stops by buoys The bars are of sufficient weight and the buoys of sufficient buoyancy that the trapeze will not easily change depth in turbulent water or if the divers experience buoyancy control problems 36 39 Trapezes are often used with diving shots When diving in tidal waters at the end of slack water the trapeze may be released from the diving shot to drift in the current as the divers make their decompression stops A decompression trapeze may also be deployed in response to a signal from the divers in which case some care must be taken not to hit a diver while lowering the bar nbsp Basic shotline Weight and float connected by a line nbsp Bottom tensioned shotline The line passes through a ring at the weight and is tensioned by a small float often a small lift bag which can later help lift the shot as the air expands nbsp Top tensioned shotline The line passes through a ring at the float and is tensioned by a smaller weight hanging from it This weight may be hooked to the main part of the line by a sliding clip to restrain it from swinging nbsp A shotline with a lazy shot a second float with a short weighted line tethered to it at just below the depth of the deepest long decompression stop nbsp A shotline with a decompression trapeze a series of crossbars suspended from a float at each end and ballasted as necessary tethered to the main shotline Downline edit Main article Downline diving A downline is a rope leading from the surface down to the underwater workplace It allows a commercial diver to travel directly to and from the job site and to control rate of descent and ascent in the same way as using a shotline Also sometimes called a jackstay 40 A downline used for open ocean diving is much the same as a shotline but does not reach all the way to the bottom An open ocean downline is weighted at the bottom and attached to a substantial float at the surface which may be tethered to the boat It may be marked at intervals by knots or loops and may be attached to decompression trapeze system In some cases a sea anchor may be used to limit wind drift particularly if attached to a boat with significant windage 41 Upline edit Also known as a Jersey upline an upline is a line deployed by the diver and fixed to the bottom usually on a wreck to serve as a position and depth control during offshore ascents in moderate currents where the diver wants to prevent excessive drift during decompression The bio degradable natural fibre line is carried on a spool and deployed connected to an inflatable decompression buoy or lift bag at the end of the dive and the bottom end tied off to the wreck After completing decompression and surfacing the diver cuts the line free at the buoy and the line sinks and naturally decomposes over a few months citation needed Positive buoyancy emergency ascent upline edit A similar application is used for emergency ascent when the diver is unable to establish neutral to negative buoyancy or when this is expected to occur at some point during the ascent and the diver has a decompression obligation as when ballast weights have been lost but the diver is still at the bottom and has a ratchet reel with sufficient line In this case the reel line is tied off to a sufficiently heavy or fixed object on the bottom and the diver ascends at the appropriate rate paying out line under tension and making the required decompression stops It will generally be necessary to cut the line after surfacing unless another diver is available to go down to release it This is a required skill for the CMAS Self Rescue Diver certification 42 Surface marker buoy and delayed surface marker buoy edit nbsp Four stages of scuba ascent with delayed surface marker buoy Preparation deployment ascent decompression stop nbsp Diver deploying a DSMBMain article Surface marker buoy A surface marker buoy SMB with a reel and line is often used by a dive leader to allow the boat to monitor progress of the dive group This can provide the operator with a positive control of depth by remaining slightly negative and using the buoyancy of the float to support this slight over weighting This allows the line to be kept under slight tension which reduces the risk of entanglement The reel or spool used to store and roll up the line usually has slightly negative buoyancy so that if released it will hang down and not float away 43 44 A delayed or deployable surface marker buoy DSMB also known a decompression buoy is a soft inflatable tube that is attached to a reel or spool line at one end and is inflated by the diver under water and released to float to the surface running out the line as it ascends This provides information to the surface that the diver is about to ascend and from where This equipment is commonly used by recreational and technical divers and requires a certain level of skill to operate safely Once deployed it can be used for the same purposes as the standard surface marker and reel and in the same way but they are mostly used to signal the boat that the diver has started ascent as a means of accurately controlling ascent rate and stop depth or to indicate a problem in technical diving 44 45 46 47 Decompression station edit A decompression station is a place set up to facilitate the planned decompression for a dive team and to help a group of divers stay together during long decompression A simple example would be a decompression trapeze system linked to the shotline or the dive boat The decompression station may also have backup equipment stored in case of emergency and provides a visual depth reference and a physical aid to maintaining a constant depth More complex systems may include a small underwater habitat 45 In cases where a decompression habitat is used there may be less exposure to cold water if the divers can partly or completely exit the water into an air filled space equivalent to an open diving bell A habitat type decompression station can be an advantage when doing long decompressions on high oxygen partial pressure as the risks associated with oxygen toxicity are reduced and it is easier for safety divers to assist The term decompression station is associated with technical diving professional divers would generally use a wet or dry diving bell for the same purpose 45 Diving stages and wet bells edit Further information Diving bell nbsp Diving stageA diving stage sometimes known as a diving basket is a platform on which one or two divers stand which is hoisted into the water lowered to the workplace or the bottom and then hoisted up again to return the diver to the surface and out of the water This equipment is almost exclusively used by surface supplied professional divers as it requires fairly complex lifting equipment A diving stage allows the surface team to conveniently manage a diver s decompression as it can be hoisted at a controlled rate and stopped at the correct depth for decompression stops and allows the divers to rest during the ascent It also allows the divers to be relatively safely and conveniently lifted out of the water and returned to the deck or quayside 48 49 A wet bell or open bell is similar to a diving stage in concept but has an air space open to the water at the bottom in which the divers or at least their heads can shelter during ascent and descent A wet bell provides more comfort and control than a stage and allows for longer time in the water Wet bells are used for air and mixed gas and divers can decompress using oxygen from a mask at 12 m 50 A bell stage is an open platform used with a closed bell to keep the bell from getting too close to the bottom which could make it difficult or impossible for the divers to get in or out through the bottom lock It may be connected to the bell or to the clump weight The launch and recovery system LARS is the equipment used to deploy and recover a stage or diving bell The sane name is applied to the equipment used to launch and recover small submersibles and ROVs 48 Providing gases to accelerate decompression edit nbsp Technical divers preparing for a mixed gas decompression dive Note the backplate and wing setup with side mounted stage tanks containing EAN50 left side and pure oxygen right side Reducing the partial pressure of the inert gas component of the breathing mixture will accelerate decompression as the concentration gradient will be greater for a given depth This is achieved by increasing the fraction of oxygen in the breathing gas used whereas substitution of a different inert gas will not produce the desired effect Substitution may introduce counter diffusion complications owing to differing rates of diffusion of the inert gases which can lead to a net gain in total dissolved gas tension in a tissue This can lead to bubble formation and growth with decompression sickness as a consequence Partial pressure of oxygen is usually limited to 1 6 bar during in water decompression for scuba divers but can be up to 1 9 bar in water and 2 2 bar in the chamber when using the US Navy tables for surface decompression 8 and up to 2 8 bar for therapeutic decompression 51 Stage cylinders edit Open circuit scuba divers by definition are independent of surface supply and must take any gas mixture with them that is to be used on the dive However if they are confident of returning by a specific route the decompression gas may be stored at appropriate places on that route The cylinders used for this purpose are called stage cylinders and they are usually provided with a standard regulator and a submersible pressure gauge and are usually left at the stop with the regulator pressurised but the cylinder valve turned off to minimise the risk of gas loss Similar cylinders are carried by the divers when the route back is not secure They are commonly mounted as sling cylinders clipped to D rings at the sides of the diver s harness 52 Scuba divers take great care to avoid breathing oxygen enriched deco gas at great depths because of the high risk of oxygen toxicity To prevent this happening cylinders containing oxygen rich gases must always be positively identifiable One way of doing this is by marking them with their maximum operating depth as clearly as possible 52 Other safety precautions may include using different coloured regulator housing flavoured mouthpieces or simply placing a rubber band vertically across the mouthpiece as an alert 53 Surface panel gas switching edit Surface supplied divers may be supplied with a gas mixture suitable for accelerated decompression by connecting a supply to the surface gas panel and connecting it through the valve system to the divers This allows accelerated decompression usually on oxygen which can be used to a maximum depth of 20 ft 6 m in water for scuba and 30 ft 9 m on surface supply 8 Surface supplied heliox bounce divers will be provided with mixtures suitable for their current depth and the mixture may be changed several times during descent and ascent from great depths 54 Continuously variable mixture in closed circuit rebreathers edit nbsp Rebreather diver with bailout and decompression cylindersFurther information Closed circuit rebreather Closed circuit rebreathers are usually controlled to provide a fairly constant partial pressure of oxygen during the dive set point and may be reset to a richer mix higher partial pressure of oxygen for decompression The effect is to keep the partial pressure of inert gases as low as safely practicable throughout the dive This minimises the absorption of inert gas in the first place and accelerates the elimination of the inert gases during ascent 55 Surface decompression equipment editDeck decompression chambers edit nbsp A basic deck decompression chamberFurther information Decompression chamber and Diving chamber A deck decompression chamber DDC or double lock chamber is a two compartment pressure vessel for human occupation which has sufficient space in the main chamber for two or more occupants and a forechamber which can allow a person to be pressurised or decompressed while the main chamber remains under constant pressure This allows an attendant to be locked in or out during treatment of the occupant s of the main chamber There is usually also a medical lock which serves a similar function but is much smaller This is used to transfer medical material food and specimens into and out of the main chamber while it is under pressure Most deck decompression chambers are fitted with built in breathing systems BIBS which supply an alternative breathing gas to the occupants usually oxygen and discharge the exhaled gas outside the chamber so the chamber gas is not excessively enriched by oxygen which would cause an unacceptable fire hazard and require frequent flushing with chamber gas usually air 56 A deck decompression chamber is intended for surface decompression and emergency hyperbaric treatment of divers but can be used for other hyperbaric treatment under the appropriate supervision of hyperbaric medical personnel 56 Portable or mobile one and two occupant single compartment chambers are not generally intended for routine surface decompression but may be used in an emergency 56 Dry bells and Saturation systems edit nbsp Personnel transfer capsule closed bell or dry bell nbsp Part of a saturation system On the left is a part of the living space with a medical lock in the foreground To the right is the wet room on the top of which there is a flange to which the dry bell is bolted for transfer of the divers between the hyperbaric habitat and the bell Further information Diving bell and Saturation diving A Saturation System or Saturation spread typically includes a living chamber transfer chamber and submersible decompression chamber which is commonly referred to in commercial diving and military diving as the diving bell 57 PTC Personnel Transfer Capsule or SDC Submersible Decompression Chamber 58 The system can be permanently installed on a ship or ocean platform but is more commonly capable of being dismantled and moved from one vessel to another by crane The entire system is managed from a control room commonly referred to as the van where depth chamber atmosphere and other system parameters are monitored and controlled The diving bell is the elevator or lift that transfers divers from the system to the work site Typically it is mated to the system utilizing a removable clamp and is separated from the system tankage bulkhead by a trunking space a kind of short tunnel through which the divers transfer to and from the bell At the completion of work or a mission the saturation diving team is decompressed gradually back to atmospheric pressure by the slow venting of system pressure at rates of about of 15 to 30 msw 50 to 100 fsw per day schedules vary Thus the process involves only one ascent thereby mitigating the time consuming and comparatively risky process of multiple decompressions normally associated with non saturation bounce diving operations 59 The chamber gas mixture is typically controlled to maintain a nominally constant partial pressure of oxygen of between 0 3 and 0 5 bar during most of the decompression 0 44 to 0 48 bar on US Navy schedule which is below the upper limit for long term exposure 60 NOAA has used rather different saturation decompression schedules for relatively shallow less than 100 fsw air and nitrox saturation dives which use oxygen breathing when pressure is reduced to less than 55 fsw 61 The divers use surface supplied umbilical diving equipment using a breathing gas suitable for the depth and pressure such as helium and oxygen mixtures stored in large capacity high pressure cylinders 59 The gas supplies are plumbed to a control panel in the control room where they are routed to supply the system components The bell is fed via a large multi part umbilical that supplies breathing gas electrical power cable communications and hot water and may return exhaled gas to the surface for recycling The bell also is fitted with externally mounted breathing gas storage cylinders for emergency use The divers are supplied from the bell through personal excursion umbilicals 58 A hyperbaric lifeboat or hyperbaric rescue unit may be provided for emergency evacuation of saturation divers from a saturation system This would be used if the platform is at immediate risk due to fire or sinking and allows the divers under saturation to get clear of the immediate danger A hyperbaric lifeboat may be self propelled and can be operated by unpressurised crew while the occupants are under pressure It must be self sufficient for several days at sea in case of a delay in rescue due to sea conditions The crew would normally start decompression as soon as safely possible after launching 62 A dry bell may also be used for bounce dives to great depths and then used as the decompression chamber during the ascent and later on board the support vessel In this case it is not always necessary to transfer into a deck chamber as the bell is quite capable of performing this function though it would be relatively cramped as a bell is usually as small as conveniently possible to minimise weight for deployment 59 See also editDecompression sickness Disorder caused by dissolved gases forming bubbles in tissues Decompression diving Pressure reduction and its effects during ascent from depth Decompression practice Techniques and procedures for safe decompression of divers Decompression theory Theoretical modelling of decompression physiology Dive computer Instrument to calculate decompression status in real time Equivalent air depth Method of comparing decompression requirements for air and a given nitrox mix Equivalent narcotic depth Method for comparing the narcotic effects of a mixed diving gas with air History of decompression research and development Chronological list of notable events in the history of diving decompression Hyperbaric treatment schedules Planned hyperbaric exposure using a specified breathing gas as medical treatment Oxygen window Physiological effect of oxygen metabolism on the total dissolved gas concentration in venous blood Physiology of decompression The physiological basis for decompression theory and practice Decompression models Buhlmann decompression algorithm Mathematical model of tissue inert gas uptake and release with pressure change Haldane s decompression model Decompression model developed by John Scott Haldane Reduced gradient bubble model Decompression algorithm Thalmann algorithm Mathematical model for diver decompression Thermodynamic model of decompression Early model in which decompression is controlled by volume of gas bubbles forming in tissues Varying Permeability Model Decompression model and algorithm based on bubble physicsReferences edit Van Liew Hugh D Bishop B Walder P Rahn H 1965 Effects of compression on composition and absorption of tissue gas pockets Journal of Applied Physiology 20 5 927 33 doi 10 1152 jappl 1965 20 5 927 ISSN 0021 8987 OCLC 11603017 PMID 5837620 Staff 13 April 2010 Using multiple cylinders Sport Diver online magazine PADI Archived from the original on 6 March 2016 Retrieved 3 March 2016 US Navy Diving Manual Revision 6 Chpt 8 section 5 a b c Huggins 1992 Introduction page 1 a b Huggins 1992 Chpt 4 pages 1 18 a b US Navy Diving Manual Revision 6 chpt 9 sect 8 The air decompression table a b Huggins 1992 Chpt 4 page 15 a b c US Navy Diving Manual Revision 6 Chpt 9 Buhlmann Albert A 1984 Decompression Decompression Sickness Berlin New York Springer Verlag ISBN 0 387 13308 9 Buhlmann Albert A 1995 Tauchmedizin in German Berlin Springer Verlag ISBN 3 540 55581 1 Buhlmann Albert A 1992 Tauchmedizin Barotrauma Gasembolie Dekompression Dekompressionskrankheit in German Berlin Springer Verlag ISBN 3 540 55581 1 British RNPL Decompression tables PDF Royal Naval Physiological Laboratory 1972 Retrieved 2 March 2016 Adkisson G 1991 The BS AC 88 decompression tables South Pacific Underwater Medicine Society Journal 21 1 Archived from the original on 15 April 2013 Retrieved 10 January 2012 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint unfit URL link Powell 2008 Other decompression models page 203 a b Hamilton R W Jr Rogers R E Powell M R 1994 Development and validation of no stop decompression procedures for recreational diving the DSAT recreational dive planner Report Tarrytown NY Diving Science amp Technology Corp Archived from the original on 7 August 2009 Retrieved 15 June 2008 a href Template Cite report html title Template Cite report cite report a CS1 maint unfit URL link Powell 2008 Other decompression models page 209 13 Nishi R Y Tikuisis P December 1996 Current Trends in Decompression Development Statistics and Data Analysis Defense Technical Information Center Trucco Jean Noel Biard Jef Redureau Jean Yves Fauvel Yvon 3 May 1999 Table Marine National 90 MN90 Version du 03 05 1999 PDF Comite interregional Bretagne amp Pays de la Loire Commission Technique Regionale in French F F E S S M Retrieved 23 January 2017 a b c d Huggins 1992 Chpt 4 page 11 Huggins 1992 Chpt 4 page 10 Duis D 1991 Using the Recreational Diver Planner for multi level diving In Hans Jurgen K Harper Jr DE Eds International Pacifica Scientific Diving 1991 Proceedings of the American Academy of Underwater Sciences Eleventh Annual Scientific Diving Symposium held 25 30 September 1991 University of Hawaii Honolulu Hawaii Archived from the original on 15 April 2013 Retrieved 17 October 2011 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint unfit URL link Staff 2008 Introducing the eRDPML Big Blue Technical Diving News and Events Archive for August 4 2008 Big Blue Technical Diving Retrieved 7 March 2016 Huggins K E Performance of dive computers exposed to profiles with known human subject results PDF Catalina Hyperbaric Chamber Wrigley Marine Science Center University of Southern California Retrieved 6 March 2016 Departure Dive Planning and Decompression software Diverssupport com Retrieved 17 July 2012 DecoPlanner decompression simulation software Gue com Retrieved 17 July 2012 Ultimate Planner decompression planning software tool http www techdivingmag com ultimateplanner html GAP software decompression simulation software Gap software com 10 February 2008 Retrieved 17 July 2012 Beresford M Southwood P 2006 CMAS ISA Normoxic Trimix Manual 4th ed Pretoria South Africa CMAS Instructors South Africa a b Blogg S L Lang M A Mollerlokken A eds 2012 Proceedings of the Validation of Dive Computers Workshop European Underwater and Baromedical Society Symposium August 24 2011 Gdansk Trondheim Norwegian University of Science and Technology Archived from the original on 15 April 2013 Retrieved 7 March 2013 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint unfit URL link Lang M A Hamilton Jr R W 1989 Proceedings of the AAUS Dive Computer Workshop United States USC Catalina Marine Science Center p 231 Archived from the original on 7 July 2012 Retrieved 7 August 2008 a href Template Cite book html title Template Cite book cite book a CS1 maint unfit URL link a b c d e f Mollerlokken Andreas 24 August 2011 Blogg S Lesley Lang Michael A Mollerlokken Andreas eds Proceedings of Validation of Dive Computers Workshop Gdansk Poland European Underwater and Baromedical Society Archived from the original on 15 April 2013 Retrieved 3 March 2016 a href Template Cite web html title Template Cite web cite web a CS1 maint unfit URL link Azzopardi E Sayer M D J 2010 A review of the technical specifications of 47 models of diving decompression computer International Journal of the Society for Underwater Technology Society for Underwater Technology 29 2 63 70 doi 10 3723 ut 29 063 a b c Powell 2008 Other decompression models pages 213 217 US Navy Diving Manual Revision 6 Chpt 9 section 11 Variations in rate of ascent Department of Labour Diving Council 11 January 2002 Diving regulations 2001 of the Occupational Health and Safety Act 85 of 1993 Government Gazette Republic of South Africa Vol 438 no 2291 Pretoria Government Printer a b c d e f g Boan Charlotte 2014 How to deploy a shotline Dive magazine archive Syon publishing Retrieved 3 March 2016 Edmonds Carl Bennett Michael Lippmann John Mitchell Simon 2 July 2015 Equipment for recreational diving Diving and Subaquatic Medicine Fifth Edition 5 illustrated revised ed CRC Press p 45 ISBN 978 1 4822 6013 7 Retrieved 7 March 2016 Gentile Gary 1998 The Technical Diving Handbook Gary Gentile Productions ISBN 1 883056 05 5 Technical Issues Newry amp Mourne Sub Aqua Club Retrieved 28 August 2009 Barsky Steven M Christensen Robert W 2004 The Simple Guide to Commercial Diving Illustrated ed Hammerhead Press p 92 ISBN 978 0 9674305 4 6 Warlaumont John October 1991 10 6 Open ocean diving NOAA Diving Manual Diving for Science and Technology Illustrated ed DIANE Publishing pp 10 14 to 10 15 ISBN 978 1 56806 231 0 Retrieved 17 March 2017 Staff 4 March 2014 CMAS Self Rescue Diver Standard Number 2 B 31 BOD no 181 04 18 2013 CMAS Retrieved 13 April 2017 Staff 2005 2016 Surface Marker Buoys SMBs Scuba Doctor website Melbourne The Scuba Doctor Australia Retrieved 7 March 2016 a b Staff Recommendations Concerning the Use of Surface Marker Buoys PDF British Diving Safety Group Retrieved 7 March 2016 a b c Gurr Kevin August 2008 13 Operational Safety In Mount Tom Dituri Joseph eds Exploration and Mixed Gas Diving Encyclopedia 1st ed Miami Shores Florida International Association of Nitrox Divers pp 165 180 ISBN 978 0 915539 10 9 Staff 2015 Delayed surface marker buoy BSAC Safe Diving British Sub Aqua Club p 18 Archived from the original on 3 April 2012 Retrieved 7 March 2016 Nawrocky Pete 2014 We re Over Here Alert Diver online Spring 2014 Divers Alert Network Retrieved 7 March 2016 a b Staff Diving Launch And Recovery Systems Commercial Diving Equipment Submarine Manufacturing amp Products Ltd Retrieved 7 March 2016 Staff Pommec 2 diver launch and recovery system with diving basket PDF Technical Diving Equipment Pommec BV Retrieved 7 March 2016 Imbert Jean Pierre February 2006 Lang Smith eds Commercial Diving 90m Operational Aspects PDF Advanced Scientific Diving Workshop Smithsonian Institution Retrieved 30 June 2012 U S Navy Department 1975 U S Navy Diving Manual Volume 1 Change 1 U S Government Printing Office Washington D C NAVSEA 099 LP 001 9010 a b Jablonski Jarrod 2006 Details of DIR Equipment Configuration Doing it Right The Fundamentals of Better Diving High Springs Florida Global Underwater Explorers p 113 ISBN 0 9713267 0 3 Gentile Gary July 1988 Advanced Wreck Diving Guide 3rd ed Cornell Maritime Press p 60 ISBN 978 0 87033 380 4 US Navy Diving Manual Revision 6 Chpt 14 page 2 Gas nixtures US Navy Diving Manual Revision 6 Chpt 17 a b c US Navy Diving Manual Revision 6 Chpt 21 Recompression chamber operation Bevan J 1999 Diving bells through the centuries South Pacific Underwater Medicine Society Journal 29 1 ISSN 0813 1988 OCLC 16986801 Archived from the original on 11 February 2009 Retrieved 25 April 2008 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint unfit URL link a b US Navy Diving Manual Revision 6 Chpt 15 Saturation Diving a b c Beyerstein G 2006 Lang M A Smith N E eds Commercial Diving Surface Mixed Gas Sur D O2 Bell Bounce Saturation Proceedings of Advanced Scientific Diving Workshop Smithsonian Institution Washington DC Archived from the original on 21 February 2009 Retrieved 12 April 2010 a href Template Cite conference html title Template Cite conference cite conference a CS1 maint unfit URL link US Navy Diving Manual Revision 6 Chpt 15 sect 23 pp 33 seq James W Miller ed 1979 12 6 Decompression after an air or nitrogen oxygen saturation dive NOAA Diving Manual 2nd ed United States Department of Commerce Staff May 2013 Guidance on Hyperbaric Evacuation Systems PDF Guidance on Hyperbaric Evacuation Systems IMCA D 052 May 2013 International Marine Contractors Association Retrieved 6 March 2016 Sources edit Huggins Karl E 1992 Dynamics of decompression workshop Course Taught at the University of Michigan Powell Mark 2008 Deco for Divers Southend on Sea Aquapress ISBN 978 1 905492 07 7 US Navy 2006 US Navy Diving Manual 6th revision United States US Naval Sea Systems Command US Navy 2018 US Navy Diving Manual 7th revision Ch A United States US Naval Sea Systems Command External links edit nbsp Media related to Decompression equipment at Wikimedia Commons Retrieved from https en wikipedia org w index php title Decompression equipment amp oldid 1173205636 Upline, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.