fbpx
Wikipedia

Harold Orr

Harold Walter Orr CM (born April 30, 1931) is a Canadian mechanical engineer known for his work on energy-efficient construction and air leakage in houses, in particular the prioritization of energy demand reduction over active systems through the use of superinsulation and airtightness in passive design.[1] Among Orr's major technical works are Design and construction of low energy houses in Saskatchewan (1982) and Energy efficient housing on the prairies (1982).

Harold Orr
OccupationMechanical engineer 
Employer
WorksSaskatchewan Conservation House 
Awards
  • Member of the Order of Canada (2017) 

Orr worked with the Building Research Division of the National Research Council (NRC) of Canada.[1] He focused on infiltration as a major component of heat loss.[1] His research on air leakage in houses led to the development of the blower door, a tool still used today for tightness testing in houses.[2][3][4] He also helped to develop the HotCan software, which continues to be used for whole house energy analysis and energy code compliance under the name HOT2000.[5][6]

In response to the energy crisis of the 1970s, Orr proposed radical insulation and airtight construction techniques. He served as the lead engineer on the construction of the Saskatchewan Conservation House (SCH), the world's most airtight house at the time. The SCH influenced the development of energy efficiency building codes in Canada and internationally, and shaped the field of energy-efficient construction, including passive solar building design and the German Passive house.[3][7] Orr's work has earned him many accolades, including a Pioneer Award at the International Passive House Conference in Leipzig, Germany in 2015,[3] and being named a Member of the Order of Canada in 2017.[8]

Early life and education edit


Harold Walter Orr was born April 30, 1931 in Minton, Saskatchewan to Wilfred and Pearl Orr.[9] Harold Orr's lineage traces back to William Brewster, a Pilgrim leader on the Mayflower, eleven generations prior, and John Hayden Williams UEL, a United Empire Loyalist, six generations prior.[citation needed]

Harold Orr's parents were founding members of what later became Western Christian College (WCC). His father worked at various times as a carpenter, builder, preacher, principal, and teacher. His mother's positions included assistant principal, matron, and teacher. When Harold was less than a year old, his parents moved into a 'cook car' and converted their home in Minton into a summer bible school, the predecessor of the Western Christian College.[9]

That fall (1931), the Orrs moved to Radville in the Peace River District, hosting the next bible school in a meeting house. After living in British Columbia from 1936 to 1940, they returned to Radville. In 1940, they bought an 8-room house for $550 and donated it to the bible school. In 1944, they offered a site on their property on the east bank of the Souris River for the establishment of a new school site. In 1945, the school was named the Radville Christian College.[9][10] Harold and his siblings, Lois Olson (Orr), Alice Williams (Orr), Raymond Orr, P.Eng., and Verna Bastian (Orr),[11][12] completed their high school educations there.[10] Harold graduated in 1949.[13]

Following his father and grandfather, Orr became familiar with building sites from the age of 12 and trained as a carpenter.[14] After beginning to study mechanical engineering, he met and married Mary Ruth Lidbury in 1953.[15] He eventually became a father to eight children: Ruth, Nancy, Walter, May, John, Randy, Robert, and Glenda, two of whom are adopted; to 22 Grandchildren and 28 Great Grandchildren. Over the years, he and his wife have fostered four children.[citation needed]

After working as a carpenter and briefly studying architecture, Orr returned to Saskatoon, where he completed his Bachelor of Engineering in mechanical engineering (1959) and Master of Science (1962) at the University of Saskatchewan.[3][16][17] Orr was also the first president of the U of S Greystone Singers from 1958 to 1960, and designed its crest.[18]

Career edit

Orr's research career began with his Master's thesis, "Studies and Improvements to an Air Infiltration Instrument". As a master's student, Orr worked at the National Research Council (NRC) of Canada to investigate air leakage in houses. After graduating, Orr was hired by the NRC to continue his work on the problem of calculating air leakage in houses. As a student, he developed a method to measure air leakage using helium as a tracer gas, later improving this method by switching to sulphur hexafluoride.[14] His work led to the development of the blower door in the late 1970s, an instrument still used for tightness testing in houses.[19][3][17]

During the energy crisis of the 1970s, Orr served on a committee convened by the Saskatchewan Research Council (SRC) to design a passive solar house.[20][21] As part of this committee, Orr applied his carpentry background and his knowledge of heat loss to suggest a radical increase in insulation and the use of airtight construction techniques. This project resulted in the Saskatchewan Conservation House (1977), which was the most airtight house in the world at the time.[22] The Saskatchewan Conservation House (SCH) project faced challenges, including the inclusion of a government-mandated solar hot water system that proved to be expensive and inefficient. The solar component was removed after the house was sold to a private owner, after being used for two years as a model show house.[23] Nonetheless, its conservation measures, such as insulation, airtightness, and its heat-recovery ventilation system, were highly effective.[24][25] On a blower door test, a standardized measure of how rapidly air leaks out of a house at a pressure of 50 pascals (pa), most new Canadian houses of the time scored around 9 "air changes per hour" or ach @ 50 pa. The Saskatchewan Conservation House achieved measures of 0.5[26] ach@50pa.[2] The Saskatchewan Conservation House became a model for low-energy house design,[24][25] receiving as many as 1,000 visitors a week in 1978.[27]

The elements used in the project paved the way for the development of the Natural Resources Canada R2000 program. They led to the establishment of new national energy conservation protocols, the Energuide Energy efficiency building codes, for use in Canadian buildings.[28][29] Fourteen similar houses were constructed in Saskatoon in 1981,[30] using principles from the SCH.[28] The Saskatchewan Conservation House also became a model for the international Passive House (Passivhaus) building energy efficiency standard.[31] The passive house approach became influential in Germany and Europe.[23] In Saskatchewan, the first house to apply for official certification as a passive house was the Temperance Street Passive House, in 2016. It uses many of the principles Orr introduced in 1977.[32][33]

In 1982, Orr and Dumont explored the potential for doing a deep-energy retrofit on an existing building. They applied ideas from the Saskatchewan Conservation House in the first "chainsaw retrofit".[34][35] In preparation for creating a new building envelope for the house, the existing eaves and overhangs were removed at the roofline to simplify its surface. The entire house was then wrapped in a continuous polyethylene air-vapor barrier. The result was framed out and 8 inches of fiberglass insulation was added before a new facade was constructed. Blower tests of the house's air leakage showed a reduction of 90.1%, improving scores from 2.95 ach at 50 pa to 0.29 ach at 50 pa.[34]

Orr also worked with Robert Dumont to develop the energy analysis program HotCan, which continues to be used as of 2018 under the name HOT2000.[26] It is considered "a key component of Canada's home energy rating, labelling, incentive programs, and code compliance" for whole house energy analysis.[5]

Orr retired from the NRC in 1986 after 25 years of service. From 1989 to 1992, Orr was a charter Engineering faculty member at Oklahoma Christian University. In 2017, Orr received both a Lifetime Achievement Award from the Saskatchewan Energy Management Task Force[3] and the Order of Canada for his significant contributions to energy efficiency in Canadian homes.[36][8] He was lauded for his ability to communicate technical issues to a broad audience throughout his career.[3]

Awards and recognition edit

Orr has received recognition for his contributions to energy-efficient construction and for his work in the community.

  • In 1980, he was named Alumnus of the Year at Western Christian College.[37]
  • In 1989, he received a Professional Service Award from the EEBA as the first president of the Energy Efficient Buildings Association (EEBA).[38]
  • In 1999, Orr and his wife Mary Ruth Orr (née Lidbury) were awarded the Distinguished Service Award from the Western Canadian Christian Convention.[citation needed]
  • In 2003, the Association of Engineers of Saskatchewan granted Orr life membership.[39]
  • In 2013, Orr received "The Golden Blower Door" from Passive House North.[40]
  • In 2013, he received a Lifetime Achievement Award from Sustainable Buildings Canada.[41]
  • In 2015, he accepted the Pioneer Award from the Passive House Institute for the team who worked on the SCH, an international award given to trailblazers in energy-efficient construction.[42][43]
  • In 2017, Orr was named a Member of the Order of Canada for his significant contributions to energy efficiency in Canadian homes.[36][8]
  • In 2017, Orr received The Rob Dumont Energy Management Awards "Lifetime Achievement Award".[3]
  • In 2018, he was recognized as an "EEBA Legend" by the same organization.[44]
  • In 2019, he received a Lifetime Achievement Award from the Canadian Home Builders' Association.[citation needed]
  • In 2022, Orr received The Queen Elizabeth II Platinum Jubilee Medal.[45][15]
  • Passive House Canada has an annual award named after Orr meant to recognize an individual's contributions to increasing awareness of both passive house and net zero standards with government and business.[46]

Selected publications edit

Orr has contributed to the field of energy-efficient construction through numerous technical publications, including:

  • Handegord, G. O.; Orr, H. W.; Nicholson, R. G. (August 1, 1964). "Temperature conditions in three houses following simulated power shut-off - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Orr, H. W. (April 1969). "A study of the effects of edge insulation and ambient temperatures on errors in guarded hot-plate measurements - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Shirtliffe, C. J.; Orr, H. W. (April 1, 1969). "Comparison of modes of operation for guarded hot plate apparatus with emphasis on transient characteristics - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Orr, H. W. (1974). "Condensation in electrically heated houses - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Hedlin, C. P.; Orr, H. W. (1977). "A study of the use of natural gas and electricity in Saskatchewan homes - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Kumar, R.; Ireson, A. D.; Orr, H.W. (1979). "An automated air infiltration measuring system using SF[6] tracer gas in constant concentration and decay methods - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Dumont, R. S.; Orr, H. W.; Hedlin, C. P.; Makohon, J. T. (1980). "Measured energy consumption of a group of low-energy houses - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Hedlin, C. P.; Orr, H. W.; Tao, S. S. (1980). "A method for determining the thermal resistances of experimental flat roof systems using heat flow meters - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Orr, H. W.; Figley, D. A. (March 1980). "An exhaust fan apparatus for assessing the air leakage characteristics of houses - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Dumont, R. S.; Orr, H. W. (September 1981). "Cost of energy conservation measures for new housing - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Dumont, R. S.; Orr, H. W.; Figley, D. A. (November 1981). "Air tightness measurements of detached houses in the Saskatoon area - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Orr, H. W. (1982). "Energy efficient housing on the prairies - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Orr, H. W. (April 1, 1982). "Design and construction of low energy houses in Saskatchewan - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Dumont, R. S.; Lux, M. E.; Orr, H.W. (September 1, 1982). "HOTCAN: A Computer Program for Estimating the Space Heating Requirement of Residences - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Dumont, R. S.; Orr, H. W.; Lux, M. E. (December 1, 1982). "Low energy Prairie housing : a survey of some essential features - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Dumont, R. S.; Orr, H. W.; Hedlin, C. P. (1983). "Low-energy houses: measured energy-consumption figures - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.
  • Orr, H. W.; Dumont, R. S. (May 1, 1987). "A major energy conservation retrofit of a bungalow - NRC Publications Archive". nrc-publications.canada.ca. Government of Canada National Research Council.

References edit

  1. ^ a b c Ruby, Daniel (October 1981). "From the far north: lessons on how to slash fuel bills". Popular Science. Bonnier Corporation. pp. 106–108.
  2. ^ a b Paulsen, Monte (2012). "Just Build It". Canadian Geographic. 132 (3).
  3. ^ a b c d e f g h "The Rob Dumont Energy Management Awards". Saskatchewan Energy Management Task Forces. Retrieved 2023-06-08.
  4. ^ Dodge, David; Thompson, Dylan (May 6, 2016). "The first certified passive house in Saskatchewan". Pembina Institute. Retrieved 14 December 2023.
  5. ^ a b Parekh, Anil; Charron, Remi; Poirier, Simon; Roux, Louise (2018). "Testing of HOT2000 version 11 in Accordance with ASHRAE Standard 140-2014". Proceedings of eSim 2018, the 10th conference of IBPSA-Canada Montréal, QC, Canada, May 9-10, 2018 (PDF). IBPSA Canada. pp. 251–258. ISBN 9782921145886.
  6. ^ Riley, M. (June 1986). Ventilation and air quality monitoring in R-2000 homes: measurement and analysis (PDF). The R-2000 Home Progam.
  7. ^ Three Decades of Innovation in Housing Technology: 1966-1996 (PDF). Government of Canada. 1999. pp. 68–74.
  8. ^ a b c General, Office of the Secretary to the Governor. "Mr. Harold Walter Orr". The Governor General of Canada. Retrieved 2023-06-08.
  9. ^ a b c Torkelson, Lillian M. (1946). "Part One: A Vision Splendid, Chapter I: Radville Summer School". Western Christian College Background and Historical Perspective 1931 to 1995. The Gospel Herald. Retrieved 2023-06-08.
  10. ^ a b Torkelson, Lillian M. (1989). "Part 3: Western Christian College History, Diary Update 1969 - 1989". Western Christian College Background and Historical Perspective 1931 to 1995.
  11. ^ Williams, Ralph (January 2005). "Obituaries Orr, Pearl Catherine" (PDF). Gospel Herald. Vol. 70, no. 1. p. 16. Retrieved 30 November 2023.
  12. ^ "Remembering the life of Pearl Orr". Regina Leader-Post. Retrieved 2023-10-27.
  13. ^ "Graduates - History of WCC". The Old Paths Archive.
  14. ^ a b Cowell, Lucy (2015-08-19). "HPH095 : The Saskatchewan Conservation House - with Harold Orr". House Planning Help. Retrieved 2023-10-27.
  15. ^ a b Harold and Mary Orr Recognized at Saskatchewan Legislature, retrieved 2023-10-27
  16. ^ "University of Saskatchewan graduates listed". The Leader-Post. 8 May 1959. p. 28.
  17. ^ a b Fitzpatrick, Kathy (Oct 17, 2019). "All in on insulation". Green and White - Alumni and Friends. Retrieved 2023-10-10.
  18. ^ Florence, Bob (March 2, 2009). . The Star Phoenix. Archived from the original on 2014-06-06. Retrieved 2023-06-08.
  19. ^ Code, BC Energy Step (2018-12-03). "Some B.C. Builders are Reaching Step Code Specs Without Even Trying". Medium. Retrieved 2023-10-10.
  20. ^ Holladay, Martin (September 22, 2010). "THE HISTORY OF SUPER INSULATION IN NORTH AMERICA 2010 BCBEC Conference & AGM Innovative Solutions - Building Tomorrow". BCBEC. Retrieved 2023-06-09.
  21. ^ "Passive house and Passivhaus - where it started". www.ecohome.net. Retrieved 2023-06-09.
  22. ^ Moonen, Peter; Hunter, Lydia (2016-07-12). "Active Thoughts on Passive Design: Designing with wood for next-level green projects". Construction Canada. Retrieved 2023-10-10.
  23. ^ a b Huck, Nichole (Aug 5, 2015). "'Passive home' movement a success in Germany, but not in Saskatchewan where it started Canada slow to adopt green building technology first used in Saskatchewan in 1977". CBC News. Retrieved 7 December 2023.
  24. ^ a b Shurcliff, William A. (November 1986). "Superinsulated Houses". Annual Review of Energy. 11 (1): 1–24. doi:10.1146/annurev.eg.11.110186.000245.
  25. ^ a b Holladay, Martin (17 April 2009). "Forgotten Pioneers of Energy Efficiency". GreenBuildingAdvisor.
  26. ^ a b Hough, Joseph (February 16, 2018). "Towards the Passive House: A short history of energy-efficient housing in Canada (Part 2 of 5)". Canadian Contractor. Retrieved 2023-10-10.
  27. ^ Besant, Robert W.; Dumont, Robert S.; Schoenau, Greg (1 April 1979). "The Saskatchewan conservation house: Some preliminary performance results". Energy and Buildings. 2 (2): 163–174. doi:10.1016/0378-7788(79)90031-8. ISSN 0378-7788.
  28. ^ a b Hough, Joseph (2018). "Passive house pioneer to receive Order of Canada". Canadian Contractor. No. March April. p. 26. Retrieved 2023-06-08.
  29. ^ Downing, Andrew (April 17, 2018). "A closer look at the Saskatchewan Conservation House and four others". Saskatchewan Research Council. Retrieved 2023-06-09.
  30. ^ JOHNSON, BRYAN (Nov 25, 1981). "Slick gadgets can cost more than they save". The Globe and Mail; Toronto, Ont. p. 7. ISSN 0319-0714. Retrieved 2024-02-19.
  31. ^ Publisher1953 (2015-04-14). "Passive House Pioneer Award recognizes 1970s energy-efficient Canadian house | Canadian Design and Construction Report". Retrieved 2023-06-09.{{cite web}}: CS1 maint: numeric names: authors list (link)
  32. ^ Dodge, David (14 March 2016). "139. The first certified passive house in Saskatchewan". Green Energy Futures. Retrieved 7 December 2023.
  33. ^ McAdam, Bre (Nov 14, 2016). "Not your typical build: A glimpse into the Temperance Street Passive House in Saskatoon". Saskatoon StarPhoenix. Retrieved 7 December 2023.
  34. ^ a b Alter, Lloyd (February 3, 2021). "Harold Orr and the 80% Rule". Treehugger. Retrieved 2023-12-23.
  35. ^ Gibson, Scott (5 June 2015). "Building Science Pioneer Dies". GreenBuildingAdvisor. Retrieved 23 December 2023.
  36. ^ a b "Saskatoon engineer who helped improve energy efficiency in homes named to the Order of Canada". CBC News. January 31, 2019. Retrieved June 7, 2023.
  37. ^ "Alumnus of the Year - History of WCC". www.oldpaths.com. Retrieved 2023-10-10.
  38. ^ "Breakfast Sessions Tuesday Oct 16th Harold Orr C.M. P. Eng.(retired)" (PDF). High Performance Home Summit, 2018. 2018.
  39. ^ "APEGS". www.apegs.ca. Retrieved 2023-10-10.
  40. ^ Langlois, Lucie (10 October 2013). "L'événement Passive House North". La Maison du 21e siècle - Le Magazine de la Maison Saine (in French). Retrieved 7 December 2023.
  41. ^ Buckstein, M. (2013-10-16). "Sustainable development experts awarded". Construction Canada. Retrieved 2023-10-10.
  42. ^ "Harold Orr, Pioneer". Canadian Consulting Engineer. 56 (3): 46. May 2015.
  43. ^ "The Pioneer Award [Passipedia EN]". passipedia.org. Retrieved 2023-06-09.
  44. ^ GoEEBA (2018-10-16), 2018-10-16-052-rlm, retrieved 2023-10-10
  45. ^ "Queen Elizabeth II Platinum Jubilee Medal (Saskatchewan) | Heritage, Honours and Awards". Government of Saskatchewan. Retrieved 2023-10-10.
  46. ^ "Passive House Canada Recognize Three with Harold Orr Awards – Passive House Canada | Maison Passive Canada". www.passivehousecanada.com. Retrieved 2023-10-10.

harold, harold, walter, born, april, 1931, canadian, mechanical, engineer, known, work, energy, efficient, construction, leakage, houses, particular, prioritization, energy, demand, reduction, over, active, systems, through, superinsulation, airtightness, pass. Harold Walter Orr CM born April 30 1931 is a Canadian mechanical engineer known for his work on energy efficient construction and air leakage in houses in particular the prioritization of energy demand reduction over active systems through the use of superinsulation and airtightness in passive design 1 Among Orr s major technical works are Design and construction of low energy houses in Saskatchewan 1982 and Energy efficient housing on the prairies 1982 Harold OrrOccupationMechanical engineer EmployerNational Research Council Canada 1986 Oklahoma Christian University WorksSaskatchewan Conservation House AwardsMember of the Order of Canada 2017 Orr worked with the Building Research Division of the National Research Council NRC of Canada 1 He focused on infiltration as a major component of heat loss 1 His research on air leakage in houses led to the development of the blower door a tool still used today for tightness testing in houses 2 3 4 He also helped to develop the HotCan software which continues to be used for whole house energy analysis and energy code compliance under the name HOT2000 5 6 In response to the energy crisis of the 1970s Orr proposed radical insulation and airtight construction techniques He served as the lead engineer on the construction of the Saskatchewan Conservation House SCH the world s most airtight house at the time The SCH influenced the development of energy efficiency building codes in Canada and internationally and shaped the field of energy efficient construction including passive solar building design and the German Passive house 3 7 Orr s work has earned him many accolades including a Pioneer Award at the International Passive House Conference in Leipzig Germany in 2015 3 and being named a Member of the Order of Canada in 2017 8 Contents 1 Early life and education 2 Career 3 Awards and recognition 4 Selected publications 5 ReferencesEarly life and education editThis section of a biography of a living person needs additional citations for verification Please help by adding reliable sources Contentious material about living persons that is unsourced or poorly sourced must be removed immediately from the article and its talk page especially if potentially libelous Find sources Harold Orr news newspapers books scholar JSTOR October 2023 Learn how and when to remove this template message Harold Walter Orr was born April 30 1931 in Minton Saskatchewan to Wilfred and Pearl Orr 9 Harold Orr s lineage traces back to William Brewster a Pilgrim leader on the Mayflower eleven generations prior and John Hayden Williams UEL a United Empire Loyalist six generations prior citation needed Harold Orr s parents were founding members of what later became Western Christian College WCC His father worked at various times as a carpenter builder preacher principal and teacher His mother s positions included assistant principal matron and teacher When Harold was less than a year old his parents moved into a cook car and converted their home in Minton into a summer bible school the predecessor of the Western Christian College 9 That fall 1931 the Orrs moved to Radville in the Peace River District hosting the next bible school in a meeting house After living in British Columbia from 1936 to 1940 they returned to Radville In 1940 they bought an 8 room house for 550 and donated it to the bible school In 1944 they offered a site on their property on the east bank of the Souris River for the establishment of a new school site In 1945 the school was named the Radville Christian College 9 10 Harold and his siblings Lois Olson Orr Alice Williams Orr Raymond Orr P Eng and Verna Bastian Orr 11 12 completed their high school educations there 10 Harold graduated in 1949 13 Following his father and grandfather Orr became familiar with building sites from the age of 12 and trained as a carpenter 14 After beginning to study mechanical engineering he met and married Mary Ruth Lidbury in 1953 15 He eventually became a father to eight children Ruth Nancy Walter May John Randy Robert and Glenda two of whom are adopted to 22 Grandchildren and 28 Great Grandchildren Over the years he and his wife have fostered four children citation needed After working as a carpenter and briefly studying architecture Orr returned to Saskatoon where he completed his Bachelor of Engineering in mechanical engineering 1959 and Master of Science 1962 at the University of Saskatchewan 3 16 17 Orr was also the first president of the U of S Greystone Singers from 1958 to 1960 and designed its crest 18 Career editOrr s research career began with his Master s thesis Studies and Improvements to an Air Infiltration Instrument As a master s student Orr worked at the National Research Council NRC of Canada to investigate air leakage in houses After graduating Orr was hired by the NRC to continue his work on the problem of calculating air leakage in houses As a student he developed a method to measure air leakage using helium as a tracer gas later improving this method by switching to sulphur hexafluoride 14 His work led to the development of the blower door in the late 1970s an instrument still used for tightness testing in houses 19 3 17 During the energy crisis of the 1970s Orr served on a committee convened by the Saskatchewan Research Council SRC to design a passive solar house 20 21 As part of this committee Orr applied his carpentry background and his knowledge of heat loss to suggest a radical increase in insulation and the use of airtight construction techniques This project resulted in the Saskatchewan Conservation House 1977 which was the most airtight house in the world at the time 22 The Saskatchewan Conservation House SCH project faced challenges including the inclusion of a government mandated solar hot water system that proved to be expensive and inefficient The solar component was removed after the house was sold to a private owner after being used for two years as a model show house 23 Nonetheless its conservation measures such as insulation airtightness and its heat recovery ventilation system were highly effective 24 25 On a blower door test a standardized measure of how rapidly air leaks out of a house at a pressure of 50 pascals pa most new Canadian houses of the time scored around 9 air changes per hour or ach 50 pa The Saskatchewan Conservation House achieved measures of 0 5 26 ach 50pa 2 The Saskatchewan Conservation House became a model for low energy house design 24 25 receiving as many as 1 000 visitors a week in 1978 27 The elements used in the project paved the way for the development of the Natural Resources Canada R2000 program They led to the establishment of new national energy conservation protocols the Energuide Energy efficiency building codes for use in Canadian buildings 28 29 Fourteen similar houses were constructed in Saskatoon in 1981 30 using principles from the SCH 28 The Saskatchewan Conservation House also became a model for the international Passive House Passivhaus building energy efficiency standard 31 The passive house approach became influential in Germany and Europe 23 In Saskatchewan the first house to apply for official certification as a passive house was the Temperance Street Passive House in 2016 It uses many of the principles Orr introduced in 1977 32 33 In 1982 Orr and Dumont explored the potential for doing a deep energy retrofit on an existing building They applied ideas from the Saskatchewan Conservation House in the first chainsaw retrofit 34 35 In preparation for creating a new building envelope for the house the existing eaves and overhangs were removed at the roofline to simplify its surface The entire house was then wrapped in a continuous polyethylene air vapor barrier The result was framed out and 8 inches of fiberglass insulation was added before a new facade was constructed Blower tests of the house s air leakage showed a reduction of 90 1 improving scores from 2 95 ach at 50 pa to 0 29 ach at 50 pa 34 Orr also worked with Robert Dumont to develop the energy analysis program HotCan which continues to be used as of 2018 under the name HOT2000 26 It is considered a key component of Canada s home energy rating labelling incentive programs and code compliance for whole house energy analysis 5 Orr retired from the NRC in 1986 after 25 years of service From 1989 to 1992 Orr was a charter Engineering faculty member at Oklahoma Christian University In 2017 Orr received both a Lifetime Achievement Award from the Saskatchewan Energy Management Task Force 3 and the Order of Canada for his significant contributions to energy efficiency in Canadian homes 36 8 He was lauded for his ability to communicate technical issues to a broad audience throughout his career 3 Awards and recognition editOrr has received recognition for his contributions to energy efficient construction and for his work in the community In 1980 he was named Alumnus of the Year at Western Christian College 37 In 1989 he received a Professional Service Award from the EEBA as the first president of the Energy Efficient Buildings Association EEBA 38 In 1999 Orr and his wife Mary Ruth Orr nee Lidbury were awarded the Distinguished Service Award from the Western Canadian Christian Convention citation needed In 2003 the Association of Engineers of Saskatchewan granted Orr life membership 39 In 2013 Orr received The Golden Blower Door from Passive House North 40 In 2013 he received a Lifetime Achievement Award from Sustainable Buildings Canada 41 In 2015 he accepted the Pioneer Award from the Passive House Institute for the team who worked on the SCH an international award given to trailblazers in energy efficient construction 42 43 In 2017 Orr was named a Member of the Order of Canada for his significant contributions to energy efficiency in Canadian homes 36 8 In 2017 Orr received The Rob Dumont Energy Management Awards Lifetime Achievement Award 3 In 2018 he was recognized as an EEBA Legend by the same organization 44 In 2019 he received a Lifetime Achievement Award from the Canadian Home Builders Association citation needed In 2022 Orr received The Queen Elizabeth II Platinum Jubilee Medal 45 15 Passive House Canada has an annual award named after Orr meant to recognize an individual s contributions to increasing awareness of both passive house and net zero standards with government and business 46 Selected publications editOrr has contributed to the field of energy efficient construction through numerous technical publications including Handegord G O Orr H W Nicholson R G August 1 1964 Temperature conditions in three houses following simulated power shut off NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Orr H W April 1969 A study of the effects of edge insulation and ambient temperatures on errors in guarded hot plate measurements NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Shirtliffe C J Orr H W April 1 1969 Comparison of modes of operation for guarded hot plate apparatus with emphasis on transient characteristics NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Orr H W 1974 Condensation in electrically heated houses NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Hedlin C P Orr H W 1977 A study of the use of natural gas and electricity in Saskatchewan homes NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Kumar R Ireson A D Orr H W 1979 An automated air infiltration measuring system using SF 6 tracer gas in constant concentration and decay methods NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Dumont R S Orr H W Hedlin C P Makohon J T 1980 Measured energy consumption of a group of low energy houses NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Hedlin C P Orr H W Tao S S 1980 A method for determining the thermal resistances of experimental flat roof systems using heat flow meters NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Orr H W Figley D A March 1980 An exhaust fan apparatus for assessing the air leakage characteristics of houses NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Dumont R S Orr H W September 1981 Cost of energy conservation measures for new housing NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Dumont R S Orr H W Figley D A November 1981 Air tightness measurements of detached houses in the Saskatoon area NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Orr H W 1982 Energy efficient housing on the prairies NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Orr H W April 1 1982 Design and construction of low energy houses in Saskatchewan NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Dumont R S Lux M E Orr H W September 1 1982 HOTCAN A Computer Program for Estimating the Space Heating Requirement of Residences NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Dumont R S Orr H W Lux M E December 1 1982 Low energy Prairie housing a survey of some essential features NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Dumont R S Orr H W Hedlin C P 1983 Low energy houses measured energy consumption figures NRC Publications Archive nrc publications canada ca Government of Canada National Research Council Orr H W Dumont R S May 1 1987 A major energy conservation retrofit of a bungalow NRC Publications Archive nrc publications canada ca Government of Canada National Research Council References edit a b c Ruby Daniel October 1981 From the far north lessons on how to slash fuel bills Popular Science Bonnier Corporation pp 106 108 a b Paulsen Monte 2012 Just Build It Canadian Geographic 132 3 a b c d e f g h The Rob Dumont Energy Management Awards Saskatchewan Energy Management Task Forces Retrieved 2023 06 08 Dodge David Thompson Dylan May 6 2016 The first certified passive house in Saskatchewan Pembina Institute Retrieved 14 December 2023 a b Parekh Anil Charron Remi Poirier Simon Roux Louise 2018 Testing of HOT2000 version 11 in Accordance with ASHRAE Standard 140 2014 Proceedings of eSim 2018 the 10th conference of IBPSA Canada Montreal QC Canada May 9 10 2018 PDF IBPSA Canada pp 251 258 ISBN 9782921145886 Riley M June 1986 Ventilation and air quality monitoring in R 2000 homes measurement and analysis PDF The R 2000 Home Progam Three Decades of Innovation in Housing Technology 1966 1996 PDF Government of Canada 1999 pp 68 74 a b c General Office of the Secretary to the Governor Mr Harold Walter Orr The Governor General of Canada Retrieved 2023 06 08 a b c Torkelson Lillian M 1946 Part One A Vision Splendid Chapter I Radville Summer School Western Christian College Background and Historical Perspective 1931 to 1995 The Gospel Herald Retrieved 2023 06 08 a b Torkelson Lillian M 1989 Part 3 Western Christian College History Diary Update 1969 1989 Western Christian College Background and Historical Perspective 1931 to 1995 Williams Ralph January 2005 Obituaries Orr Pearl Catherine PDF Gospel Herald Vol 70 no 1 p 16 Retrieved 30 November 2023 Remembering the life of Pearl Orr Regina Leader Post Retrieved 2023 10 27 Graduates History of WCC The Old Paths Archive a b Cowell Lucy 2015 08 19 HPH095 The Saskatchewan Conservation House with Harold Orr House Planning Help Retrieved 2023 10 27 a b Harold and Mary Orr Recognized at Saskatchewan Legislature retrieved 2023 10 27 University of Saskatchewan graduates listed The Leader Post 8 May 1959 p 28 a b Fitzpatrick Kathy Oct 17 2019 All in on insulation Green and White Alumni and Friends Retrieved 2023 10 10 Florence Bob March 2 2009 Greystone alumni sing songs of praise The Star Phoenix Archived from the original on 2014 06 06 Retrieved 2023 06 08 Code BC Energy Step 2018 12 03 Some B C Builders are Reaching Step Code Specs Without Even Trying Medium Retrieved 2023 10 10 Holladay Martin September 22 2010 THE HISTORY OF SUPER INSULATION IN NORTH AMERICA 2010 BCBEC Conference amp AGM Innovative Solutions Building Tomorrow BCBEC Retrieved 2023 06 09 Passive house and Passivhaus where it started www ecohome net Retrieved 2023 06 09 Moonen Peter Hunter Lydia 2016 07 12 Active Thoughts on Passive Design Designing with wood for next level green projects Construction Canada Retrieved 2023 10 10 a b Huck Nichole Aug 5 2015 Passive home movement a success in Germany but not in Saskatchewan where it started Canada slow to adopt green building technology first used in Saskatchewan in 1977 CBC News Retrieved 7 December 2023 a b Shurcliff William A November 1986 Superinsulated Houses Annual Review of Energy 11 1 1 24 doi 10 1146 annurev eg 11 110186 000245 a b Holladay Martin 17 April 2009 Forgotten Pioneers of Energy Efficiency GreenBuildingAdvisor a b Hough Joseph February 16 2018 Towards the Passive House A short history of energy efficient housing in Canada Part 2 of 5 Canadian Contractor Retrieved 2023 10 10 Besant Robert W Dumont Robert S Schoenau Greg 1 April 1979 The Saskatchewan conservation house Some preliminary performance results Energy and Buildings 2 2 163 174 doi 10 1016 0378 7788 79 90031 8 ISSN 0378 7788 a b Hough Joseph 2018 Passive house pioneer to receive Order of Canada Canadian Contractor No March April p 26 Retrieved 2023 06 08 Downing Andrew April 17 2018 A closer look at the Saskatchewan Conservation House and four others Saskatchewan Research Council Retrieved 2023 06 09 JOHNSON BRYAN Nov 25 1981 Slick gadgets can cost more than they save The Globe and Mail Toronto Ont p 7 ISSN 0319 0714 Retrieved 2024 02 19 Publisher1953 2015 04 14 Passive House Pioneer Award recognizes 1970s energy efficient Canadian house Canadian Design and Construction Report Retrieved 2023 06 09 a href Template Cite web html title Template Cite web cite web a CS1 maint numeric names authors list link Dodge David 14 March 2016 139 The first certified passive house in Saskatchewan Green Energy Futures Retrieved 7 December 2023 McAdam Bre Nov 14 2016 Not your typical build A glimpse into the Temperance Street Passive House in Saskatoon Saskatoon StarPhoenix Retrieved 7 December 2023 a b Alter Lloyd February 3 2021 Harold Orr and the 80 Rule Treehugger Retrieved 2023 12 23 Gibson Scott 5 June 2015 Building Science Pioneer Dies GreenBuildingAdvisor Retrieved 23 December 2023 a b Saskatoon engineer who helped improve energy efficiency in homes named to the Order of Canada CBC News January 31 2019 Retrieved June 7 2023 Alumnus of the Year History of WCC www oldpaths com Retrieved 2023 10 10 Breakfast Sessions Tuesday Oct 16th Harold Orr C M P Eng retired PDF High Performance Home Summit 2018 2018 APEGS www apegs ca Retrieved 2023 10 10 Langlois Lucie 10 October 2013 L evenement Passive House North La Maison du 21e siecle Le Magazine de la Maison Saine in French Retrieved 7 December 2023 Buckstein M 2013 10 16 Sustainable development experts awarded Construction Canada Retrieved 2023 10 10 Harold Orr Pioneer Canadian Consulting Engineer 56 3 46 May 2015 The Pioneer Award Passipedia EN passipedia org Retrieved 2023 06 09 GoEEBA 2018 10 16 2018 10 16 052 rlm retrieved 2023 10 10 Queen Elizabeth II Platinum Jubilee Medal Saskatchewan Heritage Honours and Awards Government of Saskatchewan Retrieved 2023 10 10 Passive House Canada Recognize Three with Harold Orr Awards Passive House Canada Maison Passive Canada www passivehousecanada com Retrieved 2023 10 10 Retrieved from https en wikipedia org w index php title Harold Orr amp oldid 1212744975, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.