VRLA battery

A valve regulated lead–acid (VRLA) battery, commonly known as a sealed lead–acid (SLA) battery,[1] is a type of lead–acid battery characterized by a limited amount of electrolyte ("starved" electrolyte) absorbed in a plate separator or formed into a gel; proportioning of the negative and positive plates so that oxygen recombination is facilitated within the cell; and the presence of a relief valve that retains the battery contents independent of the position of the cells.[2]

A 12V VRLA battery, typically used in small uninterruptible power supplies and emergency lamps

There are two primary types of VRLA batteries, absorbent glass mat (AGM) and gel cell (gel battery).[3] Gel cells add silica dust to the electrolyte, forming a thick putty like gel. AGM (absorbent glass mat) batteries feature fiberglass mesh between the battery plates which serves to contain the electrolyte and separate the plates. Both types of VRLA batteries offer advantages and disadvantages compared to flooded vented lead–acid (VLA) batteries or each other.[4]

Due to their construction, the gel cell and AGM types of VRLA can be mounted in any orientation, and do not require constant maintenance. The term "maintenance free" is a misnomer as VRLA batteries still require cleaning and regular functional testing. They are widely used in large portable electrical devices, off-grid power systems and similar roles, where large amounts of storage are needed at a lower cost than other low maintenance technologies like lithium ion.

History edit

The first lead–acid gel battery was invented by Elektrotechnische Fabrik Sonneberg in 1934.[5] The modern gel or VRLA battery was invented by Otto Jache of Sonnenschein in 1957.[6][7] The first AGM cell was the Cyclon, patented by Gates Rubber Corporation in 1972 and now produced by EnerSys.[8] The cyclon is a spiral wound cell with thin lead foil electrodes. A number of manufacturers seized on the technology to implement it in cells with conventional flat plates. In the mid 1980s, two UK companies, Chloride and Tungstone, simultaneously introduced ten year life AGM batteries in capacities up to 400 Ah, stimulated by a British Telecom specification for batteries for support of new digital exchanges. In the same period, Gates acquired another UK company, Varley, specialising in aircraft and military batteries. Varley adapted the Cyclon lead foil technology to produce flat plate batteries with exceptional high rate output. These gained approval for a variety of aircraft including the BAE 125 and 146 business jets, the Harrier and its derivative the AV8B, and some F16 variants as the first alternatives to then standard nickel–cadmium (Ni-Cd) batteries.[6]

Basic principle edit

 
Cutaway view of a 1953 automotive battery

Lead–acid cells consist of two plates of lead, which serve as electrodes, suspended in an electrolyte consisting of diluted sulfuric acid. VRLA cells have the same chemistry, except the electrolyte is immobilized. In AGM this is accomplished with a fiberglass mat; in gel batteries or "gel cells", the electrolyte is in the form of a paste like gel created by adding silica and other gelling agents to the electrolyte.[9]

When a cell discharges, the lead and diluted acid undergo a chemical reaction that produces lead sulfate and water. When a cell is subsequently charged, the lead sulfate and water are turned back into lead and acid. In all lead–acid battery designs, charging current must be adjusted to match the ability of the battery to absorb the energy. If the charging current is too great, electrolysis will occur, decomposing water into hydrogen and oxygen, in addition to the intended conversion of lead sulfate and water into lead dioxide, lead, and sulfuric acid (the reverse of the discharge process). If these gases are allowed to escape, as in a conventional flooded cell, the battery will need to have water (or electrolyte) added from time to time. In contrast, VRLA batteries retain generated gases within the battery as long as the pressure remains within safe levels. Under normal operating conditions the gases can then recombine within the battery itself, sometimes with the help of a catalyst, and no additional electrolyte is needed.[10][11] However, if the pressure exceeds safety limits, safety valves open to allow the excess gases to escape, and in doing so regulate the pressure back to safe levels (hence "valve regulated" in "VRLA").[12]

Construction edit

Each cell in a VRLA battery has a pressure relief valve which will activate when the battery starts building pressure of hydrogen gas, generally a result of being recharged.[12]

The cell covers typically have gas diffusers built into them that allow safe dispersal of any excess hydrogen that may be formed during overcharge. They are not permanently sealed, but are designated to be maintenance free. They can be oriented in any manner, unlike normal lead–acid batteries, which must be kept upright to avoid acid spills and to keep the plates' orientation vertical. Cells may be operated with the plates horizontal (pancake style), which may improve cycle life.[13]

Absorbent glass mat (AGM) edit

AGM batteries differ from flooded lead–acid batteries in that the electrolyte is held in the glass mats, as opposed to freely flooding the plates. Very thin glass fibers are woven into a mat to increase the surface area enough to hold a sufficient amount of electrolyte on the cells for their lifetime. The fibers that compose the fine glass mat do not absorb and are not affected by the acidic electrolyte. These mats are wrung out 2–5% after being soaked in acids just prior to finish manufacturing.

The plates in an AGM battery may be of any shape. Some are flat, whereas others are bent or rolled. Both deep cycle and starting type of AGM batteries, are built into a rectangular case according to Battery Council International (BCI) battery code specifications.

AGM batteries are more resistant to self discharging than conventional batteries within a wide range of temperatures.[14]

As with lead–acid batteries, in order to maximize the life of an AGM battery, it is important to follow the manufacturer's charging specifications and the use of a voltage regulated charger is recommended.[15] There is a direct correlation between the depth of discharge (DOD) and the cycle life of the battery,[16] with differences between 500 and 1300 cycles depending on DOD.

Gel battery edit

 
Broken gel battery with white gobbets of the gelated electrolyte on the plates

Originally a kind of gel battery was produced in the early 1930s for portable valve (tube) radio LT supply (2, 4 or 6 V) by adding silica to the sulfuric acid.[17] By this time the glass case was being replaced by celluloid and later in 1930s other plastics. Earlier "wet" cells in glass jars used special valves to allow tilt from vertical to one horizontal direction in 1927 to 1931 or 1932.[18] The gel cells were less likely to leak when the portable set was handled roughly.

A modern gel battery is a VRLA battery with a gelated electrolyte; the sulfuric acid is mixed with fumed silica, which makes the resulting mass gel like and immobile. Unlike a flooded wet cell lead–acid battery, these batteries do not need to be kept upright. Gel batteries reduce the electrolyte evaporation, spillage (and subsequent corrosion problems) common to the wet cell battery, and boast greater resistance to shock and vibration. Chemically they are almost the same as wet (non sealed) batteries except that the antimony in the lead plates is replaced by calcium, and gas recombination can take place.

Applications edit

Many modern motorcycles and all-terrain vehicles (ATVs) on the market use AGM batteries to reduce likelihood of acid spilling during cornering, vibration, or after accidents, and for packaging reasons. The lighter, smaller battery can be installed at an odd angle if needed for the design of the motorcycle. Due to the higher manufacturing costs compared with flooded lead–acid batteries, AGM batteries are currently used on luxury vehicles. As vehicles become heavier and equipped with more electronic devices such as navigation and stability control, AGM batteries are being employed to lower vehicle weight and provide better electrical reliability compared with flooded lead–acid batteries.

5 series BMWs from March 2007 incorporate AGM batteries in conjunction with devices for recovering brake energy using regenerative braking and computer control to ensure the alternator charges the battery when the car is decelerating. Vehicles used in auto racing may use AGM batteries due to their vibration resistance. AGM batteries are also commonly used in classic vehicles since they are much less likely to leak electrolyte, which could damage hard to replace body panels.

Deep-cycle AGMs are also commonly used in off-grid solar power and wind power installations as an energy storage bank and in large-scale amateur robotics, such as the FIRST and IGVC competitions.

AGM batteries are routinely chosen for remote sensors such as ice monitoring stations in the Arctic. AGM batteries, due to their lack of free electrolyte, will not crack and leak in these cold environments.

VRLA batteries are used extensively in power wheelchairs and mobility scooters, as the extremely low gas and acid output makes them much safer for indoor use. VRLA batteries are also used in the uninterruptible power supply (UPS) as a backup when the electrical power goes off.

VRLA batteries are also the standard power source in sailplanes, due to their ability to withstand a variety of flight attitudes and a relatively large ambient temperature range with no adverse effects. However, charging regimes must be adapted with varying temperature.[19]

VRLA batteries are used in the US Nuclear Submarine fleet, due to their power density, elimination of gassing, reduced maintenance, and enhanced safety.[20]

AGM and gel-cell batteries are also used for recreational marine purposes, with AGM being more commonly available. AGM deep-cycle marine batteries are offered by a number of suppliers. They typically are favored for their low maintenance and spill-proof quality, although generally considered a less cost effective solution relative to traditional flooded cells.

In telecommunications applications, VRLA batteries that comply with criteria in Telcordia Technologies requirements document GR-4228, Valve-Regulated Lead–Acid (VRLA) Battery String Certification Levels Based on Requirements for Safety and Performance, are recommended for deployment in the Outside Plant (OSP) at locations such as Controlled Environmental Vaults (CEVs), Electronic Equipment Enclosures (EEEs), and huts, and in uncontrolled structures such as cabinets. Relative to VRLA in telecommunications, the use of VRLA Ohmic Measurement Type Equipment (OMTE) and OMTE-like measurement equipment is a fairly new process to evaluate telecommunications battery plants.[21] The proper use of ohmic test equipment allows battery testing without the need to remove batteries from service to perform costly and time-consuming discharge tests.

Comparison with flooded lead–acid cells edit

VRLA gel and AGM batteries offer several advantages compared with VRLA flooded lead–acid and conventional lead–acid batteries. The battery can be mounted in any position, since the valves only operate on over-pressure faults. Since the battery system is designed to be recombinant and eliminate the emission of gases on overcharge, room ventilation requirements are reduced, and no acid fume is emitted during normal operation. Flooded cell gas emissions are of little consequence in all but the smallest confined areas, and pose very little threat to a domestic user, so a wet cell battery designed for longevity gives lower costs per kWh. In a gel battery, the volume of free electrolyte that could be released on damage to the case or venting is very small. There is no need (or ability) to check the level of electrolyte or to top up water lost due to electrolysis, thus reducing inspection and maintenance requirements.[22] Wet-cell batteries can be maintained by a self-watering system or by topping up every three months. The requirement to add distilled water is normally caused by overcharging. A well-regulated system should not require top-up more often than every three months.

An underlying disadvantage with all lead–acid batteries is the requirement for a relatively long recharge cycle time arising from an inherent three-stage charging process: bulk charge, absorption charge, and (maintenance) float charge stages. All lead–acid batteries, irrespective of type, are quick to bulk charge to about 70% of capacity during which the battery will accept a large current input, determined at a voltage setpoint, within a few hours (with a charge source capable of supplying the design C-rate bulk stage current for a given Ah battery).

However, they then require a longer time spent in the current-tapering off intermediate absorption charge stage after the initial bulk charge, when the LA battery charge acceptance rate gradually reduces, and the battery will not accept a higher C-rate. When the absorption stage voltage setpoint is reached (and charge current has tapered off), the charger switches to a float voltage setpoint at a very low C-rate to maintain the battery's fully charged state indefinitely (the float stage offsets the battery's normal self-discharge over time).

If the charger fails to supply a sufficient absorption stage charge duration and C-rate (it 'plateaus' or times out, a common fault of cheap solar chargers), and a suitable float charge profile, the battery's capacity and longevity will be dramatically reduced.

To ensure maximum life, a lead–acid battery should be fully recharged as soon after a discharge cycle as possible to prevent sulfation, and kept at a full charge level by a float source when stored or idle (or stored dry new from the factory, an uncommon practice today).

When working a discharge cycle, a LA battery should be kept at a DOD of less than 50%, ideally no more than 20-40% DOD; a true[23] LA deep-cycle battery can be taken to a lower DOD (even an occasional 80%), but these greater DOD cycles always impose a longevity price.

Lead–acid battery lifetime cycles will vary with the care given, with best care they may achieve 500 to 1000 cycles. With less careful use, a lifetime as few as 100 cycles might be expected (all dependent upon the use environment too).

Because of calcium added to its plates to reduce water loss, a sealed AGM or gel battery recharges more quickly than a flooded lead–acid battery of either VRLA or conventional design.[24][25] Compared to flooded batteries, VRLA batteries are more vulnerable to thermal runaway during abusive charging. The electrolyte cannot be tested by hydrometer to diagnose improper charging that can reduce battery life.[25]

AGM automobile batteries are typically about twice the price of flooded-cell batteries in a given BCI size group; gel batteries as much as five times the price.

AGM and gel VRLA batteries:

  • Have shorter recharge time than flooded lead–acid batteries.[26]
  • Cannot tolerate overcharging: overcharging leads to premature failure.[26]
  • Have shorter useful life, compared to properly maintained wet-cell battery.[26]
  • Discharge significantly less hydrogen gas.[26]
  • AGM batteries are by nature, safer for the environment, and safer to use.
  • Can be used or positioned in any orientation.

See also edit

References edit

  1. ^ Eismin, Thomas K. (2013). Aircraft Electricity and Electronics (Sixth ed.). McGraw Hill Professional. p. 48. ISBN 978-0071799157.
  2. ^ Linden, David B.; Reddy, Thomas (2002). "24". Handbook of Batteries Third Edition. McGraw-Hill. ISBN 0-07-135978-8.
  3. ^ "Exploding Lead Acid Batteries, Mines Safety Bulletin No. 150". Australia: Queensland Government. 2015-10-27. Retrieved 2020-02-17.
  4. ^ "Selecting the Proper Lead–Acid Technology" (PDF). Trojan Battery Company, California, USA. 2018. (PDF) from the original on 2023-09-29. Retrieved 2023-09-29.
  5. ^ (PDF). Netaworld.org. Archived from the original (PDF) on 20 February 2019. Retrieved 19 February 2019.
  6. ^ a b Desmond, Kevin (2016). "Jache, Otto". Innovators in Battery Technology: Profiles of 95 Influential Electrochemists. McFarland. ISBN 978-1476622781.
  7. ^ "Handbook for Gel-VRLA-Batteries : Part 1 : Basic Principles, Design, Features" (PDF). Sonnenschein.org. Retrieved 19 February 2019.
  8. ^ John Devitt (1997). "An account of the development of the first valve-regulated lead/acid cell". Journal of Power Sources. 64 (1–2): 153–156. Bibcode:1997JPS....64..153D. doi:10.1016/S0378-7753(96)02516-5.
  9. ^ Wagner, R (2004-03-09). "13.3 Gel batteries". In Moseley, Patrick T; et al. (eds.). Valve-Regulated Lead–Acid Batteries. Elsevier Science. p. 446. ISBN 9780444507464.
  10. ^ Robert Nelson, "The Basic Chemistry of Gas Recombination in Lead–Acid Batteries", JOM 53 (1) (2001)
  11. ^ "The Basic Chemistry of Gas Recombination in Lead–Acid Batteries". TMS.org.
  12. ^ a b Ronald Dell, David Anthony James Rand, Robert Bailey, Jr., Understanding Batteries,Royal Society of Chemistry, 2001, ISBN 0854046054 p. 101, pp.120-122
  13. ^ Vaccaro, F.J.; Rhoades, J.; Le, B.; Malley, R. (October 1998). "VRLA battery capacity cycling: Influences of physical design, materials, and methods to evaluate their effect". INTELEC - Twentieth International Telecommunications Energy Conference (Cat. No.98CH36263). pp. 166–172. doi:10.1109/INTLEC.1998.793494. ISBN 0-7803-5069-3. S2CID 108814630.
  14. ^ (PDF). YuasaBatteries.com. GS Yuasa. Archived from the original (PDF) on 2017-07-12. Retrieved 2019-12-25.
  15. ^ "AGM Charging : Technical Support Desk". Support.rollsbattery.com. Retrieved 19 February 2019.
  16. ^ "AGM Discharge Characteristics : Modified on: Mon, 6 Oct, 2014". Support.rollsbattery.com. Retrieved 19 February 2019.
  17. ^ Watterson, Michael (2014-06-28). "Exide Gel-Cel Accumulator JSK2 Power-S Chloride Electrical". RadioMuseum.org. Retrieved 2015-03-01.
  18. ^ Walchhofer, Hans Martin; Watterson, Michael (2013-11-27). "Super Range Portable four A (without tuning dial)". RadioMuseum.org. Retrieved 2021-04-07.
  19. ^ Linden, Reddy (ed), Handbook of batteries, third ed, 2002
  20. ^ "Exide Earns First-Ever Production Contract Awarded by U.S. Navy for Valve-Regulated Submarine Batteries; Shift to Advanced Product Prompts Closure of Kankakee, Illinois, Battery Plant". Business Wire. 2005. Retrieved 7 September 2016.
  21. ^ GR-3169-CORE, Generic Requirements for Valve-Regulated Lead–Acid (VRLA) Battery Ohmic Measurement Type Equipment (OMTE).
  22. ^ Fink, Donald G.; Beaty, H. Wayne (1978). Standard Handbook for Electrical Engineers (Eleventh ed.). New York: McGraw-Hill. pp. 11–116. ISBN 0-07-020974-X.
  23. ^ Collins, Rod (April 7, 2015). "What is a Deep Cycle Battery?".
  24. ^ Barre, Harold (1997). Managing 12 Volts: How to Upgrade, Operate and Troubleshoot 12 Volt Electrical Systems. Summer Breeze Publishing. p. 44. ISBN 978-0-9647386-1-4.(stating sealed battery plates are hardened with calcium to reduce water loss which "raises the batteries' internal resistance and prevents rapid charging.")
  25. ^ a b Sterling, Charles (2009). . Archived from the original on 16 March 2012. Retrieved 2 February 2012.
  26. ^ a b c d Calder, Nigel (1996). Boatowner's Mechanical and Electrical Manual (2nd ed.). International Marine. p. 11. ISBN 978-0-07-009618-9.

Further reading edit

Books and papers edit

  • Valve-Regulated Lead-Acid Batteries. Edited by Patrick T. Moseley, Jurgen Garche, C.D. Parker, D.A.J. Rand. p202
  • Vinal, G.W. (1955 Jan 01) Storage batteries. A general treatise on the physics and chemistry of secondary batteries and their engineering applications. Energy Citations Database (ECD) : Document #7308501
  • John McGavack. The Absorption of Sulfur Dioxide by the Gel of Silicic Acid. Eschenbach Print. Company, 1920.

Patents edit

  • U.S. patent 417,392 – Treatment Of Porous Pots For Electric Batteries. Erhard Ludwig Mayer and Henry Liepmann
  • U.S. patent 3,271,199 – Solid Acid Storage Battery Electrolyte. Alexander Koenig et al.
  • U.S. patent 4,134,192 – Composite battery plate grid
  • U.S. patent 4,238,557 – Lead acid battery plate with starch coated glass fibers
  • U.S. patent 4,414,302 – Method of making a lead storage battery and lead storage battery made according to this method. Otto Jache's and Heinz Schroeder

External links edit

  • Why do I need a special battery for the automatic start-stop system?, published by Varta
  • Pros and cons of AGM batteries, published by Lifeline

vrla, battery, valve, regulated, lead, acid, vrla, battery, commonly, known, sealed, lead, acid, battery, type, lead, acid, battery, characterized, limited, amount, electrolyte, starved, electrolyte, absorbed, plate, separator, formed, into, proportioning, neg. A valve regulated lead acid VRLA battery commonly known as a sealed lead acid SLA battery 1 is a type of lead acid battery characterized by a limited amount of electrolyte starved electrolyte absorbed in a plate separator or formed into a gel proportioning of the negative and positive plates so that oxygen recombination is facilitated within the cell and the presence of a relief valve that retains the battery contents independent of the position of the cells 2 A 12V VRLA battery typically used in small uninterruptible power supplies and emergency lampsThere are two primary types of VRLA batteries absorbent glass mat AGM and gel cell gel battery 3 Gel cells add silica dust to the electrolyte forming a thick putty like gel AGM absorbent glass mat batteries feature fiberglass mesh between the battery plates which serves to contain the electrolyte and separate the plates Both types of VRLA batteries offer advantages and disadvantages compared to flooded vented lead acid VLA batteries or each other 4 Due to their construction the gel cell and AGM types of VRLA can be mounted in any orientation and do not require constant maintenance The term maintenance free is a misnomer as VRLA batteries still require cleaning and regular functional testing They are widely used in large portable electrical devices off grid power systems and similar roles where large amounts of storage are needed at a lower cost than other low maintenance technologies like lithium ion Contents 1 History 2 Basic principle 3 Construction 4 Absorbent glass mat AGM 5 Gel battery 6 Applications 7 Comparison with flooded lead acid cells 8 See also 9 References 10 Further reading 10 1 Books and papers 10 2 Patents 11 External linksHistory editThe first lead acid gel battery was invented by Elektrotechnische Fabrik Sonneberg in 1934 5 The modern gel or VRLA battery was invented by Otto Jache of Sonnenschein in 1957 6 7 The first AGM cell was the Cyclon patented by Gates Rubber Corporation in 1972 and now produced by EnerSys 8 The cyclon is a spiral wound cell with thin lead foil electrodes A number of manufacturers seized on the technology to implement it in cells with conventional flat plates In the mid 1980s two UK companies Chloride and Tungstone simultaneously introduced ten year life AGM batteries in capacities up to 400 Ah stimulated by a British Telecom specification for batteries for support of new digital exchanges In the same period Gates acquired another UK company Varley specialising in aircraft and military batteries Varley adapted the Cyclon lead foil technology to produce flat plate batteries with exceptional high rate output These gained approval for a variety of aircraft including the BAE 125 and 146 business jets the Harrier and its derivative the AV8B and some F16 variants as the first alternatives to then standard nickel cadmium Ni Cd batteries 6 Basic principle editMain article Lead acid battery nbsp Cutaway view of a 1953 automotive batteryLead acid cells consist of two plates of lead which serve as electrodes suspended in an electrolyte consisting of diluted sulfuric acid VRLA cells have the same chemistry except the electrolyte is immobilized In AGM this is accomplished with a fiberglass mat in gel batteries or gel cells the electrolyte is in the form of a paste like gel created by adding silica and other gelling agents to the electrolyte 9 When a cell discharges the lead and diluted acid undergo a chemical reaction that produces lead sulfate and water When a cell is subsequently charged the lead sulfate and water are turned back into lead and acid In all lead acid battery designs charging current must be adjusted to match the ability of the battery to absorb the energy If the charging current is too great electrolysis will occur decomposing water into hydrogen and oxygen in addition to the intended conversion of lead sulfate and water into lead dioxide lead and sulfuric acid the reverse of the discharge process If these gases are allowed to escape as in a conventional flooded cell the battery will need to have water or electrolyte added from time to time In contrast VRLA batteries retain generated gases within the battery as long as the pressure remains within safe levels Under normal operating conditions the gases can then recombine within the battery itself sometimes with the help of a catalyst and no additional electrolyte is needed 10 11 However if the pressure exceeds safety limits safety valves open to allow the excess gases to escape and in doing so regulate the pressure back to safe levels hence valve regulated in VRLA 12 Construction editEach cell in a VRLA battery has a pressure relief valve which will activate when the battery starts building pressure of hydrogen gas generally a result of being recharged 12 The cell covers typically have gas diffusers built into them that allow safe dispersal of any excess hydrogen that may be formed during overcharge They are not permanently sealed but are designated to be maintenance free They can be oriented in any manner unlike normal lead acid batteries which must be kept upright to avoid acid spills and to keep the plates orientation vertical Cells may be operated with the plates horizontal pancake style which may improve cycle life 13 Absorbent glass mat AGM editAGM batteries differ from flooded lead acid batteries in that the electrolyte is held in the glass mats as opposed to freely flooding the plates Very thin glass fibers are woven into a mat to increase the surface area enough to hold a sufficient amount of electrolyte on the cells for their lifetime The fibers that compose the fine glass mat do not absorb and are not affected by the acidic electrolyte These mats are wrung out 2 5 after being soaked in acids just prior to finish manufacturing The plates in an AGM battery may be of any shape Some are flat whereas others are bent or rolled Both deep cycle and starting type of AGM batteries are built into a rectangular case according to Battery Council International BCI battery code specifications AGM batteries are more resistant to self discharging than conventional batteries within a wide range of temperatures 14 As with lead acid batteries in order to maximize the life of an AGM battery it is important to follow the manufacturer s charging specifications and the use of a voltage regulated charger is recommended 15 There is a direct correlation between the depth of discharge DOD and the cycle life of the battery 16 with differences between 500 and 1300 cycles depending on DOD Gel battery editThis section needs additional citations for verification Please help improve this article by adding citations to reliable sources in this section Unsourced material may be challenged and removed December 2019 Learn how and when to remove this template message nbsp Broken gel battery with white gobbets of the gelated electrolyte on the platesOriginally a kind of gel battery was produced in the early 1930s for portable valve tube radio LT supply 2 4 or 6 V by adding silica to the sulfuric acid 17 By this time the glass case was being replaced by celluloid and later in 1930s other plastics Earlier wet cells in glass jars used special valves to allow tilt from vertical to one horizontal direction in 1927 to 1931 or 1932 18 The gel cells were less likely to leak when the portable set was handled roughly A modern gel battery is a VRLA battery with a gelated electrolyte the sulfuric acid is mixed with fumed silica which makes the resulting mass gel like and immobile Unlike a flooded wet cell lead acid battery these batteries do not need to be kept upright Gel batteries reduce the electrolyte evaporation spillage and subsequent corrosion problems common to the wet cell battery and boast greater resistance to shock and vibration Chemically they are almost the same as wet non sealed batteries except that the antimony in the lead plates is replaced by calcium and gas recombination can take place Applications editMany modern motorcycles and all terrain vehicles ATVs on the market use AGM batteries to reduce likelihood of acid spilling during cornering vibration or after accidents and for packaging reasons The lighter smaller battery can be installed at an odd angle if needed for the design of the motorcycle Due to the higher manufacturing costs compared with flooded lead acid batteries AGM batteries are currently used on luxury vehicles As vehicles become heavier and equipped with more electronic devices such as navigation and stability control AGM batteries are being employed to lower vehicle weight and provide better electrical reliability compared with flooded lead acid batteries 5 series BMWs from March 2007 incorporate AGM batteries in conjunction with devices for recovering brake energy using regenerative braking and computer control to ensure the alternator charges the battery when the car is decelerating Vehicles used in auto racing may use AGM batteries due to their vibration resistance AGM batteries are also commonly used in classic vehicles since they are much less likely to leak electrolyte which could damage hard to replace body panels Deep cycle AGMs are also commonly used in off grid solar power and wind power installations as an energy storage bank and in large scale amateur robotics such as the FIRST and IGVC competitions AGM batteries are routinely chosen for remote sensors such as ice monitoring stations in the Arctic AGM batteries due to their lack of free electrolyte will not crack and leak in these cold environments VRLA batteries are used extensively in power wheelchairs and mobility scooters as the extremely low gas and acid output makes them much safer for indoor use VRLA batteries are also used in the uninterruptible power supply UPS as a backup when the electrical power goes off VRLA batteries are also the standard power source in sailplanes due to their ability to withstand a variety of flight attitudes and a relatively large ambient temperature range with no adverse effects However charging regimes must be adapted with varying temperature 19 VRLA batteries are used in the US Nuclear Submarine fleet due to their power density elimination of gassing reduced maintenance and enhanced safety 20 AGM and gel cell batteries are also used for recreational marine purposes with AGM being more commonly available AGM deep cycle marine batteries are offered by a number of suppliers They typically are favored for their low maintenance and spill proof quality although generally considered a less cost effective solution relative to traditional flooded cells In telecommunications applications VRLA batteries that comply with criteria in Telcordia Technologies requirements document GR 4228 Valve Regulated Lead Acid VRLA Battery String Certification Levels Based on Requirements for Safety and Performance are recommended for deployment in the Outside Plant OSP at locations such as Controlled Environmental Vaults CEVs Electronic Equipment Enclosures EEEs and huts and in uncontrolled structures such as cabinets Relative to VRLA in telecommunications the use of VRLA Ohmic Measurement Type Equipment OMTE and OMTE like measurement equipment is a fairly new process to evaluate telecommunications battery plants 21 The proper use of ohmic test equipment allows battery testing without the need to remove batteries from service to perform costly and time consuming discharge tests Comparison with flooded lead acid cells editVRLA gel and AGM batteries offer several advantages compared with VRLA flooded lead acid and conventional lead acid batteries The battery can be mounted in any position since the valves only operate on over pressure faults Since the battery system is designed to be recombinant and eliminate the emission of gases on overcharge room ventilation requirements are reduced and no acid fume is emitted during normal operation Flooded cell gas emissions are of little consequence in all but the smallest confined areas and pose very little threat to a domestic user so a wet cell battery designed for longevity gives lower costs per kWh In a gel battery the volume of free electrolyte that could be released on damage to the case or venting is very small There is no need or ability to check the level of electrolyte or to top up water lost due to electrolysis thus reducing inspection and maintenance requirements 22 Wet cell batteries can be maintained by a self watering system or by topping up every three months The requirement to add distilled water is normally caused by overcharging A well regulated system should not require top up more often than every three months An underlying disadvantage with all lead acid batteries is the requirement for a relatively long recharge cycle time arising from an inherent three stage charging process bulk charge absorption charge and maintenance float charge stages All lead acid batteries irrespective of type are quick to bulk charge to about 70 of capacity during which the battery will accept a large current input determined at a voltage setpoint within a few hours with a charge source capable of supplying the design C rate bulk stage current for a given Ah battery However they then require a longer time spent in the current tapering off intermediate absorption charge stage after the initial bulk charge when the LA battery charge acceptance rate gradually reduces and the battery will not accept a higher C rate When the absorption stage voltage setpoint is reached and charge current has tapered off the charger switches to a float voltage setpoint at a very low C rate to maintain the battery s fully charged state indefinitely the float stage offsets the battery s normal self discharge over time If the charger fails to supply a sufficient absorption stage charge duration and C rate it plateaus or times out a common fault of cheap solar chargers and a suitable float charge profile the battery s capacity and longevity will be dramatically reduced To ensure maximum life a lead acid battery should be fully recharged as soon after a discharge cycle as possible to prevent sulfation and kept at a full charge level by a float source when stored or idle or stored dry new from the factory an uncommon practice today When working a discharge cycle a LA battery should be kept at a DOD of less than 50 ideally no more than 20 40 DOD a true 23 LA deep cycle battery can be taken to a lower DOD even an occasional 80 but these greater DOD cycles always impose a longevity price Lead acid battery lifetime cycles will vary with the care given with best care they may achieve 500 to 1000 cycles With less careful use a lifetime as few as 100 cycles might be expected all dependent upon the use environment too Because of calcium added to its plates to reduce water loss a sealed AGM or gel battery recharges more quickly than a flooded lead acid battery of either VRLA or conventional design 24 25 Compared to flooded batteries VRLA batteries are more vulnerable to thermal runaway during abusive charging The electrolyte cannot be tested by hydrometer to diagnose improper charging that can reduce battery life 25 AGM automobile batteries are typically about twice the price of flooded cell batteries in a given BCI size group gel batteries as much as five times the price AGM and gel VRLA batteries Have shorter recharge time than flooded lead acid batteries 26 Cannot tolerate overcharging overcharging leads to premature failure 26 Have shorter useful life compared to properly maintained wet cell battery 26 Discharge significantly less hydrogen gas 26 AGM batteries are by nature safer for the environment and safer to use Can be used or positioned in any orientation See also editList of battery types Sand battery Peukert s lawReferences edit Eismin Thomas K 2013 Aircraft Electricity and Electronics Sixth ed McGraw Hill Professional p 48 ISBN 978 0071799157 Linden David B Reddy Thomas 2002 24 Handbook of Batteries Third Edition McGraw Hill ISBN 0 07 135978 8 Exploding Lead Acid Batteries Mines Safety Bulletin No 150 Australia Queensland Government 2015 10 27 Retrieved 2020 02 17 Selecting the Proper Lead Acid Technology PDF Trojan Battery Company California USA 2018 Archived PDF from the original on 2023 09 29 Retrieved 2023 09 29 A Brief History of Batteries and Stored Energy PDF Netaworld org Archived from the original PDF on 20 February 2019 Retrieved 19 February 2019 a b Desmond Kevin 2016 Jache Otto Innovators in Battery Technology Profiles of 95 Influential Electrochemists McFarland ISBN 978 1476622781 Handbook for Gel VRLA Batteries Part 1 Basic Principles Design Features PDF Sonnenschein org Retrieved 19 February 2019 John Devitt 1997 An account of the development of the first valve regulated lead acid cell Journal of Power Sources 64 1 2 153 156 Bibcode 1997JPS 64 153D doi 10 1016 S0378 7753 96 02516 5 Wagner R 2004 03 09 13 3 Gel batteries In Moseley Patrick T et al eds Valve Regulated Lead Acid Batteries Elsevier Science p 446 ISBN 9780444507464 Robert Nelson The Basic Chemistry of Gas Recombination in Lead Acid Batteries JOM 53 1 2001 The Basic Chemistry of Gas Recombination in Lead Acid Batteries TMS org a b Ronald Dell David Anthony James Rand Robert Bailey Jr Understanding Batteries Royal Society of Chemistry 2001 ISBN 0854046054 p 101 pp 120 122 Vaccaro F J Rhoades J Le B Malley R October 1998 VRLA battery capacity cycling Influences of physical design materials and methods to evaluate their effect INTELEC Twentieth International Telecommunications Energy Conference Cat No 98CH36263 pp 166 172 doi 10 1109 INTLEC 1998 793494 ISBN 0 7803 5069 3 S2CID 108814630 Technical Manual Powersports Batteries PDF YuasaBatteries com GS Yuasa Archived from the original PDF on 2017 07 12 Retrieved 2019 12 25 AGM Charging Technical Support Desk Support rollsbattery com Retrieved 19 February 2019 AGM Discharge Characteristics Modified on Mon 6 Oct 2014 Support rollsbattery com Retrieved 19 February 2019 Watterson Michael 2014 06 28 Exide Gel Cel Accumulator JSK2 Power S Chloride Electrical RadioMuseum org Retrieved 2015 03 01 Walchhofer Hans Martin Watterson Michael 2013 11 27 Super Range Portable four A without tuning dial RadioMuseum org Retrieved 2021 04 07 Linden Reddy ed Handbook of batteries third ed 2002 Exide Earns First Ever Production Contract Awarded by U S Navy for Valve Regulated Submarine Batteries Shift to Advanced Product Prompts Closure of Kankakee Illinois Battery Plant Business Wire 2005 Retrieved 7 September 2016 GR 3169 CORE Generic Requirements for Valve Regulated Lead Acid VRLA Battery Ohmic Measurement Type Equipment OMTE Fink Donald G Beaty H Wayne 1978 Standard Handbook for Electrical Engineers Eleventh ed New York McGraw Hill pp 11 116 ISBN 0 07 020974 X Collins Rod April 7 2015 What is a Deep Cycle Battery Barre Harold 1997 Managing 12 Volts How to Upgrade Operate and Troubleshoot 12 Volt Electrical Systems Summer Breeze Publishing p 44 ISBN 978 0 9647386 1 4 stating sealed battery plates are hardened with calcium to reduce water loss which raises the batteries internal resistance and prevents rapid charging a b Sterling Charles 2009 FAQ What is the Best Battery System to Use for an Auxiliary Charging System Archived from the original on 16 March 2012 Retrieved 2 February 2012 a b c d Calder Nigel 1996 Boatowner s Mechanical and Electrical Manual 2nd ed International Marine p 11 ISBN 978 0 07 009618 9 Further reading editBooks and papers edit Valve Regulated Lead Acid Batteries Edited by Patrick T Moseley Jurgen Garche C D Parker D A J Rand p202 Vinal G W 1955 Jan 01 Storage batteries A general treatise on the physics and chemistry of secondary batteries and their engineering applications Energy Citations Database ECD Document 7308501 John McGavack The Absorption of Sulfur Dioxide by the Gel of Silicic Acid Eschenbach Print Company 1920 Patents edit U S patent 417 392 Treatment Of Porous Pots For Electric Batteries Erhard Ludwig Mayer and Henry Liepmann U S patent 3 271 199 Solid Acid Storage Battery Electrolyte Alexander Koenig et al U S patent 4 134 192 Composite battery plate grid U S patent 4 238 557 Lead acid battery plate with starch coated glass fibers U S patent 4 414 302 Method of making a lead storage battery and lead storage battery made according to this method Otto Jache s and Heinz SchroederExternal links editWhy do I need a special battery for the automatic start stop system published by Varta Pros and cons of AGM batteries published by Lifeline Retrieved from https en wikipedia org w index php title VRLA battery amp oldid 1200495906 Gel battery, wikipedia, wiki, book, books, library,