A concrete slab is a common structural element of modern buildings, consisting of a flat, horizontal surface made of cast concrete. Steel-reinforced slabs, typically between 100 and 500 mm thick, are most often used to construct floors and ceilings, while thinner mud slabs may be used for exterior paving (see below).[1][2]

Suspended slab under construction, with the formwork still in place
Suspended slab formwork and rebar in place, ready for concrete pour.

In many domestic and industrial buildings, a thick concrete slab supported on foundations or directly on the subsoil, is used to construct the ground floor. These slabs are generally classified as ground-bearing or suspended. A slab is ground-bearing if it rests directly on the foundation, otherwise the slab is suspended.[3] For multi-story buildings, there are several common slab designs (see § Design for more types):

  • Beam and block, also referred to as rib and block, is mostly used in residential and industrial applications. This slab type is made up of pre-stressed beams and hollow blocks and are temporarily propped until set, typically after 21 days.
  • A hollow core slab which is precast and installed on site with a crane
  • In high rise buildings and skyscrapers, thinner, pre-cast concrete slabs are slung between the steel frames to form the floors and ceilings on each level. Cast in-situ slabs are used in high rise buildings and large shopping complexes as well as houses. These in-situ slabs are cast on site using shutters and reinforced steel.

On technical drawings, reinforced concrete slabs are often abbreviated to "r.c.c. slab" or simply "r.c.". Calculations and drawings are often done by structural engineers in CAD software.

Thermal performance

Energy efficiency has become a primary concern for the construction of new buildings, and the prevalence of concrete slabs calls for careful consideration of its thermal properties in order to minimise wasted energy.[4] Concrete has similar thermal properties to masonry products, in that it has a relatively high thermal mass and is a good conductor of heat.

In some special cases, the thermal properties of concrete have been employed, for example as a heatsink in nuclear power plants or a thermal buffer in industrial freezers.[5]

Thermal conductivity

Thermal conductivity of a concrete slab indicates the rate of heat transfer through the solid mass by conduction, usually in regard to heat transfer to or from the ground. The coefficient of thermal conductivity, k, is proportional to density of the concrete, among other factors.[4] The primary influences on conductivity are moisture content, type of aggregate, type of cement, constituent proportions, and temperature. These various factors complicate the theoretical evaluation of a k-value, since each component has a different conductivity when isolated, and the position and proportion of each components affects the overall conductivity. To simplify this, particles of aggregate may be considered to be suspended in the homogeneous cement. Campbell-Allen and Thorne (1963) derived a formula for the theoretical thermal conductivity of concrete.[5] In practice this formula is rarely applied, but remains relevant for theoretical use. Subsequently, Valore (1980) developed another formula in terms of overall density.[6] However, this study concerned hollow concrete blocks and its results are unverified for concrete slabs.

The actual value of k varies significantly in practice, and is usually between 0.8 and 2.0 W m−1 K−1.[7] This is relatively high when compared to other materials, for example the conductivity of wood may be as low as 0.04 W m−1 K−1. One way of mitigating the effects of thermal conduction is to introduce insulation (see § Insulation).

Thermal mass

The second consideration is the high thermal mass of concrete slabs, which applies similarly to walls and floors, or wherever concrete is used within the thermal envelope. Concrete has a relatively high thermal mass, meaning that it takes a long time to respond to changes in ambient temperature.[8] This is a disadvantage when rooms are heated intermittently and require a quick response, as it takes longer to warm the entire building, including the slab. However, the high thermal mass is an advantage in climates with large daily temperature swings, where the slab acts as a regulator, keeping the building cool by day and warm by night.

Typically concrete slabs perform better than implied by their R-value.[4] The R-value does not consider thermal mass, since it is tested under constant temperature conditions. Thus, when a concrete slab is subjected to fluctuating temperatures, it will respond more slowly to these changes and in many cases increase the efficiency of a building.[4] In reality, there are many factors which contribute to the effect of thermal mass, including the depth and composition of the slab, as well as other properties of the building such as orientation and windows.

Thermal mass is also related to thermal diffusivity, heat capacity and insulation. Concrete has low thermal diffusivity, high heat capacity, and its thermal mass is negatively affected by insulation (e.g. carpet).[4]

Insulation

Without insulation, concrete slabs cast directly on the ground can cause a significant amount of extraneous energy transfer by conduction, resulting in either lost heat or unwanted heat. In modern construction, concrete slabs are usually cast above a layer of insulation such as expanded polystyrene, and the slab may contain underfloor heating pipes.[9] However, there are still uses for a slab that is not insulated, for example in outbuildings which are not heated or cooled to room temperature (see § Mud slabs). In these cases, casting the slab directly onto a substrate of aggregate will maintain the slab near the temperature of the substrate throughout the year, and can prevent both freezing and overheating.

A common type of insulated slab is the beam and block system (mentioned above) which is modified by replacing concrete blocks with expanded polystyrene blocks.[10] This not only allows for better insulation but decreases the weight of slab which has a positive effect on load bearing walls and foundations.

 
Formwork set for concrete pour.
 
Concrete poured into formwork. This slab is ground-bearing and reinforced with steel rebar.

Design

Ground-bearing slabs

Ground-bearing slabs, also known as "on-ground" or "slab-on-grade", are commonly used for ground floors on domestic and some commercial applications. It is an economical and quick construction method for sites that have non-reactive soil and little slope.[11]

For ground-bearing slabs, it is important to design the slab around the type of soil, since some soils such as clay are too dynamic to support a slab consistently across its entire area. This results in cracking and deformation, potentially leading to structural failure of any members attached to the floor, such as wall studs.[11]

Levelling the site before pouring concrete is an important step, as sloping ground will cause the concrete to cure unevenly and will result in differential expansion. In some cases, a naturally sloping site may be levelled simply by removing soil from the uphill site. If a site has a more significant grade, it may be a candidate for the "cut and fill" method, where soil from the higher ground is removed, and the lower ground is built up with fill.[12]

In addition to filling the downhill side, this area of the slab may be supported on concrete piers which extend into the ground. In this case, the fill material is less important structurally as the dead weight of the slab is supported by the piers. However, the fill material is still necessary to support the curing concrete and its reinforcement.

There are two common methods of filling - controlled fill and rolled fill.[12]

  • Controlled fill: Fill material is compacted in several layers by a vibrating plate or roller. Sand fills areas up to around 800 mm deep, and clay may be used to fill areas up to 400 mm deep. However, clay is much more reactive than sand, so it should be used sparingly and carefully. Clay must be moist during compaction to homogenise it.[12]
  • Rolled fill: Fill is repeatedly compacted by an excavator, but this method of compaction is less effective than a vibrator or roller. Thus, the regulations on maximum depth are typically stricter.

Proper curing of ground-bearing concrete is necessary to obtain adequate strength. Since these slabs are inevitably poured on-site (rather than precast as some suspended slabs are), it can be difficult to control conditions to optimize the curing process. This is usually aided by a membrane, either plastic (temporary) or a liquid compound (permanent).[13]

Ground-bearing slabs are usually supplemented with some form of reinforcement, often steel rebar. However, in some cases such as concrete roads, it is acceptable to use an unreinforced slab if it is adequately engineered (see below).

Suspended slabs

For a suspended slab, there are a number of designs to improve the strength-to-weight ratio. In all cases the top surface remains flat, and the underside is modulated:

  • A corrugated slab is designed when the concrete is poured into a corrugated steel tray, more commonly called decking. This steel tray improves strength of the slab, and prevents the slab from bending under its own weight. The corrugations run in one direction only.
  • A ribbed slab gives considerably more strength in one direction. This is achieved with concrete beams bearing load between piers or columns, and thinner, integral ribs in the perpendicular direction. An analogy in carpentry would be a subfloor of bearers and joists. Ribbed slabs have higher load ratings than corrugated or flat slabs, but are inferior to waffle slabs.[14]
  • A waffle slab gives added strength in both directions using a matrix of recessed segments beneath the slab.[15] This is the same principle used in the ground-bearing version, the waffle slab foundation. Waffle slabs are usually deeper than ribbed slabs of equivalent strength, and are heavier hence require stronger foundations. However, they provide increased mechanical strength in two dimensions, a characteristic important for vibration resistance and soil movement.[16]
 
The exposed underside of a waffle slab used in a multi-storey building

Unreinforced slabs

Unreinforced or "plain"[17] slabs are becoming rare and have limited practical applications, with one exception being the mud slab (see below). They were once common in the USA, but the economic value of reinforced ground-bearing slabs has become more appealing for many engineers.[9] Without reinforcement, the entire load on these slabs is supported by the strength of the concrete, which becomes a vital factor. As a result, any stress induced by a load, static or dynamic, must be within the limit of the concrete's flexural strength to prevent cracking.[18] Since unreinforced concrete is relatively very weak in tension, it is important to consider the effects of tensile stress caused by reactive soil, wind uplift, thermal expansion, and cracking.[19] One of the most common applications for unreinforced slabs is in concrete roads.

Mud slabs

Mud slabs, also known as rat slabs, are thinner than the more common suspended or ground-bearing slabs (usually 50 to 150 mm), and usually contain no reinforcement.[20] This makes them economical and easy to install for temporary or low-usage purposes such as subfloors, crawlspaces, pathways, paving, and levelling surfaces.[21] In general, they may be used for any application which requires a flat, clean surface. This includes use as a base or "sub-slab" for a larger structural slab. On uneven or steep surfaces, this preparatory measure is necessary to provide a flat surface on which to install rebar and waterproofing membranes.[9] In this application, a mud slab also prevents the plastic bar chairs from sinking into soft topsoil which can cause spalling due to incomplete coverage of the steel. Sometimes a mud slab may be a substitute for coarse aggregate. Mud slabs typically have a moderately rough surface, finished with a float.[9]

 
Substrate and rebar prepared for pouring a mud slab

Axes of support

One-way slabs

A one-way slab has moment-resisting reinforcement only in its short axis, and is used when the moment in the long axis is negligible.[22] Such designs include corrugated slabs and ribbed slabs. Non-reinforced slabs may also be considered one-way if they are supported on only two opposite sides (i.e. they are supported in one axis). A one-way reinforced slab may be stronger than a two-way non-reinforced slab, depending on the type of load.

The calculation of reinforcement requirements for a one-way slab can be extremely tedious and time-consuming, and one can never be completely certain of the best design.[citation needed] Even minor changes to the project can necessitate recalculation of the reinforcement requirements. There are many factors to consider during the structural structure design of one-way slabs, including:

  • Load calculations
  • Bending moment calculation
  • Acceptable depth of flexure and deflection
  • Type and distribution of reinforcing steel

Two-way slabs

A two-way slab has moment resisting reinforcement in both directions.[23] This may be implemented due to application requirements such as heavy loading, vibration resistance, clearance below the slab, or other factors. However, an important characteristic governing the requirement of a two-way slab is the ratio of the two horizontal lengths. If   where   is the short dimension and   is the long dimension, then moment in both directions should be considered in design.[24] In other words, if the axial ratio is greater than two, a two-way slab is required.

A non-reinforced slab is two-way if it is supported in both horizontal axes.

Construction

A concrete slab may be prefabricated (precast), or constructed on site.

Prefabricated

Prefabricated concrete slabs are built in a factory and transported to the site, ready to be lowered into place between steel or concrete beams. They may be pre-stressed (in the factory), post-stressed (on site), or unstressed.[9] It is vital that the wall supporting structure is built to the correct dimensions, or the slabs may not fit.

On-site

On-site concrete slabs are built on the building site using formwork - a type of boxing into which the wet concrete is poured. If the slab is to be reinforced, the rebars, or metal bars, are positioned within the formwork before the concrete is poured in.[25] Plastic-tipped metal or plastic bar chairs, are used to hold the rebar away from the bottom and sides of the form-work, so that when the concrete sets it completely envelops the reinforcement. This concept is known as concrete cover. For a ground-bearing slab, the formwork may consist only of side walls pushed into the ground. For a suspended slab, the formwork is shaped like a tray, often supported by a temporary scaffold until the concrete sets.

The formwork is commonly built from wooden planks and boards, plastic, or steel. On commercial building sites, plastic and steel are gaining popularity as they save labour.[26] On low-budget or small-scale jobs, for instance when laying a concrete garden path, wooden planks are very common. After the concrete has set the wood may be removed, or left there permanently.

In some cases formwork is not necessary - for instance, a ground slab surrounded by brick or block foundation walls, where the walls act as the sides of the tray and hardcore (rubble) acts as the base.

See also

References

  1. ^ Garber, G. Design and Construction of Concrete Floors. 2nd ed. Amsterdam: Butterworth-Heinemann, 2006. 47. Print.
  2. ^ Duncan, Chester I. Soils and Foundations for Architects and Engineers. New York: Van Nostrand Reinhold, 1992. 299. Print.
  3. ^ "Ground slabs - Introduction". www.dlsweb.rmit.edu.au. Retrieved 2017-12-07.
  4. ^ a b c d e Cavanaugh, Kevin; et al. (2002). Guide to Thermal Properties of Concrete and Masonry Systems: Reported by ACI Committee 122. American Concrete Institute.
  5. ^ a b Campbell-Allen, D.; Thorne, C.P. (March 1963). "The thermal conductivity of concrete". Magazine of Concrete Research. 15 (43): 39–48. doi:10.1680/macr.1963.15.43.39. UDC 691.32.001:536.21:691.322.
  6. ^ Valore, R.C. Jr. (February 1980). "Calculation of U-values of Hollow Concrete Masonry". Concrete International. 2: 40–63.
  7. ^ Young, Hugh D. (1992). "Table 15.5". University Physics (7th ed.). Addison Wesley. ISBN 0201529815.
  8. ^ Sabnis, Gajanan M.; Juhl, William (2016). "Chapter 4: Sustainability through Thermal Mass of Concrete". Green Building with Concrete: Sustainable Design and Construction (2nd ed.). Taylor & Francis Group. ISBN 978-1-4987-0411-3.
  9. ^ a b c d e Garber, George (2006). Design and Construction of Concrete Floors (2nd ed.). Amsterdam: Butterworth-Heinemann. ISBN 978-0-7506-6656-5.
  10. ^ "Thermal Insulation of Floors" (PDF). Dow Construction Products. p. 11. Retrieved 9 May 2019.
  11. ^ a b McKinney, Arthur W.; et al. (2006). Design of Slabs-on-Ground: Reported by ACI Committee 360 (PDF). American Concrete Institute.
  12. ^ a b c Staines, Allan (2014). The Australian House Building Manual. Pinedale Press. pp. 40–41. ISBN 978-1-875217-07-6.
  13. ^ (PDF). Engineering.com. National Ready Mixed Concrete Association. Archived from the original (PDF) on 4 April 2019. Retrieved 4 April 2019.
  14. ^ (PDF). Kaset Kalip. Archived from the original (PDF) on 29 March 2018. Retrieved 4 April 2019.
  15. ^ "Ribbed and waffle slabs". www.concretecentre.com. Retrieved 2019-04-04.
  16. ^ Concrete Framed Buildings: A Guide to Design and Construction. MPA The Concrete Centre. 2016. ISBN 978-1-904818-40-3.
  17. ^ Garrison, Tim (19 February 2014). . Civil & Structural Engineer. Archived from the original on 8 May 2019. Retrieved 8 May 2019.
  18. ^ Walker, Wayne. "Reinforcement for slabs on ground". Concrete Construction. Retrieved 8 May 2019.
  19. ^ "Rupture depth of an unreinforced concrete slab on grade" (PDF). Aluminium Association of Florida, Inc.
  20. ^ Arcoma, Peter. "What is a mud slab?". Builder-Questions.com. Retrieved 8 May 2019.
  21. ^ Postma, Mark; et al. "Floor Slabs". Whole Building Design Guide. National Institute of Building Sciences. Retrieved 8 May 2019.
  22. ^ Gilbert, R. I. (1980). UNICIV Report 211 (PDF). University of New South Wales.
  23. ^ Prieto-Portar, L. A. (2008). (PDF). Archived from the original (PDF) on 2017-08-29. Retrieved 2019-04-04.
  24. ^ "What is the difference between one way and two way slab?". Basic Civil Engineering. 16 June 2019. Retrieved 8 July 2019.
  25. ^ Concrete Basics: A Guide to Concrete Practice (6th ed.). Cement Concrete & Aggregates Australia. 2004. p. 53.
  26. ^ Nemati, Kamran M. (2005). (PDF). Tokyo Institute of Technology. Archived from the original (PDF) on 12 July 2018. Retrieved 4 April 2019.

External links

  • Concrete Basics: concrete Slab Cutting services provider
  • Super Insulated Slab Foundations
  • Design of Slabs on Ground

concrete, slab, concrete, slab, common, structural, element, modern, buildings, consisting, flat, horizontal, surface, made, cast, concrete, steel, reinforced, slabs, typically, between, thick, most, often, used, construct, floors, ceilings, while, thinner, sl. A concrete slab is a common structural element of modern buildings consisting of a flat horizontal surface made of cast concrete Steel reinforced slabs typically between 100 and 500 mm thick are most often used to construct floors and ceilings while thinner mud slabs may be used for exterior paving see below 1 2 Suspended slab under construction with the formwork still in place Suspended slab formwork and rebar in place ready for concrete pour In many domestic and industrial buildings a thick concrete slab supported on foundations or directly on the subsoil is used to construct the ground floor These slabs are generally classified as ground bearing or suspended A slab is ground bearing if it rests directly on the foundation otherwise the slab is suspended 3 For multi story buildings there are several common slab designs see Design for more types Beam and block also referred to as rib and block is mostly used in residential and industrial applications This slab type is made up of pre stressed beams and hollow blocks and are temporarily propped until set typically after 21 days A hollow core slab which is precast and installed on site with a crane In high rise buildings and skyscrapers thinner pre cast concrete slabs are slung between the steel frames to form the floors and ceilings on each level Cast in situ slabs are used in high rise buildings and large shopping complexes as well as houses These in situ slabs are cast on site using shutters and reinforced steel On technical drawings reinforced concrete slabs are often abbreviated to r c c slab or simply r c Calculations and drawings are often done by structural engineers in CAD software Contents 1 Thermal performance 1 1 Thermal conductivity 1 2 Thermal mass 1 3 Insulation 2 Design 2 1 Ground bearing slabs 2 2 Suspended slabs 2 3 Unreinforced slabs 2 3 1 Mud slabs 2 4 Axes of support 2 4 1 One way slabs 2 4 2 Two way slabs 3 Construction 3 1 Prefabricated 3 2 On site 4 See also 5 References 6 External linksThermal performance EditEnergy efficiency has become a primary concern for the construction of new buildings and the prevalence of concrete slabs calls for careful consideration of its thermal properties in order to minimise wasted energy 4 Concrete has similar thermal properties to masonry products in that it has a relatively high thermal mass and is a good conductor of heat In some special cases the thermal properties of concrete have been employed for example as a heatsink in nuclear power plants or a thermal buffer in industrial freezers 5 Thermal conductivity Edit Thermal conductivity of a concrete slab indicates the rate of heat transfer through the solid mass by conduction usually in regard to heat transfer to or from the ground The coefficient of thermal conductivity k is proportional to density of the concrete among other factors 4 The primary influences on conductivity are moisture content type of aggregate type of cement constituent proportions and temperature These various factors complicate the theoretical evaluation of a k value since each component has a different conductivity when isolated and the position and proportion of each components affects the overall conductivity To simplify this particles of aggregate may be considered to be suspended in the homogeneous cement Campbell Allen and Thorne 1963 derived a formula for the theoretical thermal conductivity of concrete 5 In practice this formula is rarely applied but remains relevant for theoretical use Subsequently Valore 1980 developed another formula in terms of overall density 6 However this study concerned hollow concrete blocks and its results are unverified for concrete slabs The actual value of k varies significantly in practice and is usually between 0 8 and 2 0 W m 1 K 1 7 This is relatively high when compared to other materials for example the conductivity of wood may be as low as 0 04 W m 1 K 1 One way of mitigating the effects of thermal conduction is to introduce insulation see Insulation Thermal mass Edit The second consideration is the high thermal mass of concrete slabs which applies similarly to walls and floors or wherever concrete is used within the thermal envelope Concrete has a relatively high thermal mass meaning that it takes a long time to respond to changes in ambient temperature 8 This is a disadvantage when rooms are heated intermittently and require a quick response as it takes longer to warm the entire building including the slab However the high thermal mass is an advantage in climates with large daily temperature swings where the slab acts as a regulator keeping the building cool by day and warm by night Typically concrete slabs perform better than implied by their R value 4 The R value does not consider thermal mass since it is tested under constant temperature conditions Thus when a concrete slab is subjected to fluctuating temperatures it will respond more slowly to these changes and in many cases increase the efficiency of a building 4 In reality there are many factors which contribute to the effect of thermal mass including the depth and composition of the slab as well as other properties of the building such as orientation and windows Thermal mass is also related to thermal diffusivity heat capacity and insulation Concrete has low thermal diffusivity high heat capacity and its thermal mass is negatively affected by insulation e g carpet 4 Insulation Edit Without insulation concrete slabs cast directly on the ground can cause a significant amount of extraneous energy transfer by conduction resulting in either lost heat or unwanted heat In modern construction concrete slabs are usually cast above a layer of insulation such as expanded polystyrene and the slab may contain underfloor heating pipes 9 However there are still uses for a slab that is not insulated for example in outbuildings which are not heated or cooled to room temperature see Mud slabs In these cases casting the slab directly onto a substrate of aggregate will maintain the slab near the temperature of the substrate throughout the year and can prevent both freezing and overheating A common type of insulated slab is the beam and block system mentioned above which is modified by replacing concrete blocks with expanded polystyrene blocks 10 This not only allows for better insulation but decreases the weight of slab which has a positive effect on load bearing walls and foundations Formwork set for concrete pour Concrete poured into formwork This slab is ground bearing and reinforced with steel rebar Design EditFurther information Marcus method Ground bearing slabs Edit See also Shallow foundation Slab on grade Ground bearing slabs also known as on ground or slab on grade are commonly used for ground floors on domestic and some commercial applications It is an economical and quick construction method for sites that have non reactive soil and little slope 11 For ground bearing slabs it is important to design the slab around the type of soil since some soils such as clay are too dynamic to support a slab consistently across its entire area This results in cracking and deformation potentially leading to structural failure of any members attached to the floor such as wall studs 11 Levelling the site before pouring concrete is an important step as sloping ground will cause the concrete to cure unevenly and will result in differential expansion In some cases a naturally sloping site may be levelled simply by removing soil from the uphill site If a site has a more significant grade it may be a candidate for the cut and fill method where soil from the higher ground is removed and the lower ground is built up with fill 12 In addition to filling the downhill side this area of the slab may be supported on concrete piers which extend into the ground In this case the fill material is less important structurally as the dead weight of the slab is supported by the piers However the fill material is still necessary to support the curing concrete and its reinforcement There are two common methods of filling controlled fill and rolled fill 12 Controlled fill Fill material is compacted in several layers by a vibrating plate or roller Sand fills areas up to around 800 mm deep and clay may be used to fill areas up to 400 mm deep However clay is much more reactive than sand so it should be used sparingly and carefully Clay must be moist during compaction to homogenise it 12 Rolled fill Fill is repeatedly compacted by an excavator but this method of compaction is less effective than a vibrator or roller Thus the regulations on maximum depth are typically stricter Proper curing of ground bearing concrete is necessary to obtain adequate strength Since these slabs are inevitably poured on site rather than precast as some suspended slabs are it can be difficult to control conditions to optimize the curing process This is usually aided by a membrane either plastic temporary or a liquid compound permanent 13 Ground bearing slabs are usually supplemented with some form of reinforcement often steel rebar However in some cases such as concrete roads it is acceptable to use an unreinforced slab if it is adequately engineered see below Suspended slabs Edit For a suspended slab there are a number of designs to improve the strength to weight ratio In all cases the top surface remains flat and the underside is modulated A corrugated slab is designed when the concrete is poured into a corrugated steel tray more commonly called decking This steel tray improves strength of the slab and prevents the slab from bending under its own weight The corrugations run in one direction only A ribbed slab gives considerably more strength in one direction This is achieved with concrete beams bearing load between piers or columns and thinner integral ribs in the perpendicular direction An analogy in carpentry would be a subfloor of bearers and joists Ribbed slabs have higher load ratings than corrugated or flat slabs but are inferior to waffle slabs 14 A waffle slab gives added strength in both directions using a matrix of recessed segments beneath the slab 15 This is the same principle used in the ground bearing version the waffle slab foundation Waffle slabs are usually deeper than ribbed slabs of equivalent strength and are heavier hence require stronger foundations However they provide increased mechanical strength in two dimensions a characteristic important for vibration resistance and soil movement 16 The exposed underside of a waffle slab used in a multi storey building Unreinforced slabs Edit Unreinforced or plain 17 slabs are becoming rare and have limited practical applications with one exception being the mud slab see below They were once common in the USA but the economic value of reinforced ground bearing slabs has become more appealing for many engineers 9 Without reinforcement the entire load on these slabs is supported by the strength of the concrete which becomes a vital factor As a result any stress induced by a load static or dynamic must be within the limit of the concrete s flexural strength to prevent cracking 18 Since unreinforced concrete is relatively very weak in tension it is important to consider the effects of tensile stress caused by reactive soil wind uplift thermal expansion and cracking 19 One of the most common applications for unreinforced slabs is in concrete roads Mud slabs Edit Mud slabs also known as rat slabs are thinner than the more common suspended or ground bearing slabs usually 50 to 150 mm and usually contain no reinforcement 20 This makes them economical and easy to install for temporary or low usage purposes such as subfloors crawlspaces pathways paving and levelling surfaces 21 In general they may be used for any application which requires a flat clean surface This includes use as a base or sub slab for a larger structural slab On uneven or steep surfaces this preparatory measure is necessary to provide a flat surface on which to install rebar and waterproofing membranes 9 In this application a mud slab also prevents the plastic bar chairs from sinking into soft topsoil which can cause spalling due to incomplete coverage of the steel Sometimes a mud slab may be a substitute for coarse aggregate Mud slabs typically have a moderately rough surface finished with a float 9 Substrate and rebar prepared for pouring a mud slab Axes of support Edit One way slabs Edit A one way slab has moment resisting reinforcement only in its short axis and is used when the moment in the long axis is negligible 22 Such designs include corrugated slabs and ribbed slabs Non reinforced slabs may also be considered one way if they are supported on only two opposite sides i e they are supported in one axis A one way reinforced slab may be stronger than a two way non reinforced slab depending on the type of load The calculation of reinforcement requirements for a one way slab can be extremely tedious and time consuming and one can never be completely certain of the best design citation needed Even minor changes to the project can necessitate recalculation of the reinforcement requirements There are many factors to consider during the structural structure design of one way slabs including Load calculations Bending moment calculation Acceptable depth of flexure and deflection Type and distribution of reinforcing steelTwo way slabs Edit A two way slab has moment resisting reinforcement in both directions 23 This may be implemented due to application requirements such as heavy loading vibration resistance clearance below the slab or other factors However an important characteristic governing the requirement of a two way slab is the ratio of the two horizontal lengths If l x l y lt 2 displaystyle l x l y lt 2 where l x displaystyle l x is the short dimension and l y displaystyle l y is the long dimension then moment in both directions should be considered in design 24 In other words if the axial ratio is greater than two a two way slab is required A non reinforced slab is two way if it is supported in both horizontal axes Construction EditA concrete slab may be prefabricated precast or constructed on site Prefabricated Edit Prefabricated concrete slabs are built in a factory and transported to the site ready to be lowered into place between steel or concrete beams They may be pre stressed in the factory post stressed on site or unstressed 9 It is vital that the wall supporting structure is built to the correct dimensions or the slabs may not fit On site Edit On site concrete slabs are built on the building site using formwork a type of boxing into which the wet concrete is poured If the slab is to be reinforced the rebars or metal bars are positioned within the formwork before the concrete is poured in 25 Plastic tipped metal or plastic bar chairs are used to hold the rebar away from the bottom and sides of the form work so that when the concrete sets it completely envelops the reinforcement This concept is known as concrete cover For a ground bearing slab the formwork may consist only of side walls pushed into the ground For a suspended slab the formwork is shaped like a tray often supported by a temporary scaffold until the concrete sets The formwork is commonly built from wooden planks and boards plastic or steel On commercial building sites plastic and steel are gaining popularity as they save labour 26 On low budget or small scale jobs for instance when laying a concrete garden path wooden planks are very common After the concrete has set the wood may be removed or left there permanently In some cases formwork is not necessary for instance a ground slab surrounded by brick or block foundation walls where the walls act as the sides of the tray and hardcore rubble acts as the base See also EditShallow foundation Commonly used for ground bearing slabs Hollow core slab Voided slab one way spanning Voided biaxial slab Voided slab two way spanning Formwork Precast concrete Reinforced concrete Rebar Concrete coverReferences Edit Garber G Design and Construction of Concrete Floors 2nd ed Amsterdam Butterworth Heinemann 2006 47 Print Duncan Chester I Soils and Foundations for Architects and Engineers New York Van Nostrand Reinhold 1992 299 Print Ground slabs Introduction www dlsweb rmit edu au Retrieved 2017 12 07 a b c d e Cavanaugh Kevin et al 2002 Guide to Thermal Properties of Concrete and Masonry Systems Reported by ACI Committee 122 American Concrete Institute a b Campbell Allen D Thorne C P March 1963 The thermal conductivity of concrete Magazine of Concrete Research 15 43 39 48 doi 10 1680 macr 1963 15 43 39 UDC 691 32 001 536 21 691 322 Valore R C Jr February 1980 Calculation of U values of Hollow Concrete Masonry Concrete International 2 40 63 Young Hugh D 1992 Table 15 5 University Physics 7th ed Addison Wesley ISBN 0201529815 Sabnis Gajanan M Juhl William 2016 Chapter 4 Sustainability through Thermal Mass of Concrete Green Building with Concrete Sustainable Design and Construction 2nd ed Taylor amp Francis Group ISBN 978 1 4987 0411 3 a b c d e Garber George 2006 Design and Construction of Concrete Floors 2nd ed Amsterdam Butterworth Heinemann ISBN 978 0 7506 6656 5 Thermal Insulation of Floors PDF Dow Construction Products p 11 Retrieved 9 May 2019 a b McKinney Arthur W et al 2006 Design of Slabs on Ground Reported by ACI Committee 360 PDF American Concrete Institute a b c Staines Allan 2014 The Australian House Building Manual Pinedale Press pp 40 41 ISBN 978 1 875217 07 6 Concrete in Practice 11 Curing In Place Concrete PDF Engineering com National Ready Mixed Concrete Association Archived from the original PDF on 4 April 2019 Retrieved 4 April 2019 Ribbed Slabs Datasheet PDF Kaset Kalip Archived from the original PDF on 29 March 2018 Retrieved 4 April 2019 Ribbed and waffle slabs www concretecentre com Retrieved 2019 04 04 Concrete Framed Buildings A Guide to Design and Construction MPA The Concrete Centre 2016 ISBN 978 1 904818 40 3 Garrison Tim 19 February 2014 Clearing the confusion on plain concrete Civil amp Structural Engineer Archived from the original on 8 May 2019 Retrieved 8 May 2019 Walker Wayne Reinforcement for slabs on ground Concrete Construction Retrieved 8 May 2019 Rupture depth of an unreinforced concrete slab on grade PDF Aluminium Association of Florida Inc Arcoma Peter What is a mud slab Builder Questions com Retrieved 8 May 2019 Postma Mark et al Floor Slabs Whole Building Design Guide National Institute of Building Sciences Retrieved 8 May 2019 Gilbert R I 1980 UNICIV Report 211 PDF University of New South Wales Prieto Portar L A 2008 EGN 5439 The Design of Tall Buildings Lecture 14 The Design of Reinforced Concrete Slabs PDF Archived from the original PDF on 2017 08 29 Retrieved 2019 04 04 What is the difference between one way and two way slab Basic Civil Engineering 16 June 2019 Retrieved 8 July 2019 Concrete Basics A Guide to Concrete Practice 6th ed Cement Concrete amp Aggregates Australia 2004 p 53 Nemati Kamran M 2005 Temporary Structures Formwork for Concrete PDF Tokyo Institute of Technology Archived from the original PDF on 12 July 2018 Retrieved 4 April 2019 External links Edit Wikimedia Commons has media related to Concrete slabs Concrete Basics A Guide to Concrete Practice Concrete Basics concrete Slab Cutting services provider Super Insulated Slab Foundations Design of Slabs on Ground Retrieved from https en wikipedia org w index php title Concrete slab amp oldid 1129412510, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.