Thermosiphon (or thermosyphon) is a method of passive heat exchange, based on natural convection, which circulates a fluid without the necessity of a mechanical pump. Thermosiphoning is used for circulation of liquids and volatile gases in heating and cooling applications such as heat pumps, water heaters, boilers and furnaces. Thermosiphoning also occurs across air temperature gradients such as those utilized in a wood fire chimney or solar chimney.

Thermosyphon circulation in a simple solar water heater (not a working model; there is no water supply to replenish the tank when the tap is used)

This circulation can either be open-loop, as when the substance in a holding tank is passed in one direction via a heated transfer tube mounted at the bottom of the tank to a distribution point—even one mounted above the originating tank—or it can be a vertical closed-loop circuit with return to the original container. Its purpose is to simplify the transfer of liquid or gas while avoiding the cost and complexity of a conventional pump.

Simple thermosiphon Edit

Natural convection of the liquid starts when heat transfer to the liquid gives rise to a temperature difference from one side of the loop to the other. The phenomenon of thermal expansion means that a temperature difference will have a corresponding difference in density across the loop. The warmer fluid on one side of the loop is less dense and thus more buoyant than the cooler fluid on the other side. The warmer fluid will "float" above the cooler fluid, and the cooler fluid will "sink" below the warmer fluid. This phenomenon of natural convection is known by the saying "heat rises". Convection moves the heated liquid upwards in the system as it is simultaneously replaced by cooler liquid returning by gravity. A good thermosiphon has very little hydraulic resistance so that liquid can flow easily under the relatively low pressure produced by natural convection.

Heat pipes Edit

In some situations the flow of liquid may be reduced further, or stopped, perhaps because the loop is not entirely full of liquid. In this case, the system no longer convects, so it is not a usual "thermosiphon".

Heat can still be transferred in this system by the evaporation and condensation of vapor; however, the system is properly classified as a heat pipe thermosyphon.[1][2] If the system also contains other fluids, such as air, then the heat flux density will be less than in a real heat pipe, which contains only a single substance.

The thermosiphon has been sometimes incorrectly described as a 'gravity return heat pipe'.[3] Heat pipes usually have a wick to return the condensate to the evaporator via capillary action. A wick is not needed in a thermosiphon because gravity moves the liquid.[4] The wick allows heat pipes to transfer heat when there is no gravity, which is useful in space. A thermosiphon is "simpler" than a heat pipe.[5]

(Single-phase) thermosiphons can only transfer heat "upward", or away from the acceleration vector. Thus, orientation is much more important for thermosiphons than for heatpipes. Also, thermosiphons can fail because of a bubble in the loop, and require a circulating loop of pipes.

Reboilers and calandria Edit

If the piping of a thermosiphon resists flow, or excessive heat is applied, the liquid may boil. Since the gas is more buoyant than the liquid, the convective pressure is greater. This is a well known invention called a reboiler. A group of reboilers attached to a pair of plena is called a calandria. In some circumstances, for example the cooling system for an older (pre 1950s) car, the boiling of the fluid will cause the system to stop working, as the volume of steam created displaces too much of the water and circulation stops.

The term "phase change thermosiphon" is a misnomer and should be avoided.[citation needed] When phase change occurs in a thermosiphon, it means that the system either does not have enough fluid, or it is too small to transfer all of the heat by convection alone. To improve the performance, either more fluid is needed (possibly in a larger thermosiphon), or all other fluids (including air) should be pumped out of the loop.

Solar energy Edit

 
Solar heating system featuring a thermosiphon

Thermosiphons are used in some liquid-based solar heating systems to heat a liquid such as water. The water is heated passively by solar energy and relies on heat energy being transferred from the sun to a solar collector. The heat from the collector can be transferred to water in two ways: directly where water circulates through the collector, or indirectly where an anti-freeze solution carries the heat from the collector and transfers it to water in the tank via a heat exchanger. Convection allows for the movement of the heated liquid out of the solar collector to be replaced by colder liquid which is in turn heated. Due to this principle, it is necessary for the water to be stored in a tank above the collector.[6]

Architecture Edit

 
Thermosiphon array at the Fairbanks International Airport, used to chill the permafrost upon which the buildings of the airport are built. The building foundations are at risk of dislocation if the permafrost thaws.

In locations historically dominated by permafrost conditions, thermosiphons may be used to counter adverse geologic forces on the foundations of buildings, pipelines and other structures caused by the thawing of the permafrost.[7] A study published in 2006 by oil giant ConocoPhillips reports that Alaska's permafrost, upon which much of the state's infrastructure is built, has degraded since 1982 amid record warm temperatures.[8] According to the Alaska Climate Research Center at the University of Alaska Fairbanks, between 1949 and 2018 the average annual temperature in Alaska rose 4.0 degrees Fahrenheit, with an increase of 7.2 degrees Fahrenheit over the winter.[9]

Computing Edit

Thermosiphons are used for watercooling internal computer components,[10] most commonly the processor. While any suitable liquid can be used, water is the easiest liquid to use in thermosiphon systems. Unlike traditional watercooling systems, thermosiphon systems do not rely on a pump but on convection for the movement of heated water (which may become vapour) from the components upwards to a heat exchanger. There the water is cooled and is ready to be recirculated. The most commonly used heat exchanger is a radiator, where air is blown actively through a fan system to condense the vapour to a liquid. The liquid is recirculated through the system, thus repeating the process. No pump is required. The cycle of evaporation and condensation is driven by the difference in temperature.

Uses Edit

Without proper cooling, a modern processor chip can rapidly reach temperatures that cause it to malfunction. Even with a common heat sink and fan attached, typical processor operating temperatures may still reach up to 70 °C (160 °F). A thermosiphon can efficiently transfer heat over a much wider temperature range and can typically maintain the processor temperature 10–20 °C cooler than a traditional heat sink and fan. In some cases, it is also possible that a thermosiphon may cover multiple heat sources and, design-wise, be more compact than an appropriately sized conventional heat sink and fan.

Drawbacks Edit

Thermosiphons must be mounted such that vapor rises up and liquid flows down to the boiler, with no bends in the tubing for liquid to pool. Also, the thermosiphon's fan that cools the gas needs cool air to operate. The system has to be completely airtight; if not, the process of thermosiphon will not take effect and cause the water to only evaporate over a small period of time.

Engine cooling Edit

 
1937 diagram of engine cooling entirely by thermosiphon circulation

Some early cars, motor vehicles, and engine-powered farm and industrial equipment used thermosiphon circulation to move cooling water between their cylinder block and radiator. This method of water circulation depends on keeping enough cool air moving past the radiator to provide a sufficient temperature differential; the air movement was accomplished by the forward motion of the vehicle and by the use of fans. As engine power increased, increased flow of water was required, so engine-driven pumps were added to assist circulation. More compact engines began to use smaller radiators and require more convoluted flow patterns, so the water circulation became entirely dependent on the pump and might even be reversed against its natural direction. An engine that circulates its cooling water only by thermosiphon is susceptible to overheating during prolonged periods of idling or very slow travel since the lack of forward motion provides too little airflow past the radiator, unless one or more fans are able to move enough air by themselves. Thermosiphon systems are also very sensitive to low coolant level, i.e. losing only a small amount of coolant stops the circulation; a pump-driven system is much more robust and can typically handle a lower coolant level.

Espresso Machines Edit

Many espresso machine designs use a thermosiphon in order to maintain a stable temperature.

The iconic E-61 espresso machine has a group head with a thermosiphon. This group head is common on many espresso machines today.

Some lever espresso machines have a double wall around the piston in their group that is used for a thermosiphon. A modern example would be the machines from Londinium.


See also Edit

References Edit

  1. ^ . simmakers.com. Simmakers Ltd. 2017. Archived from the original on 5 Mar 2021. Retrieved 23 Jan 2021.
  2. ^ Holubec I (2008). "Flat Loop Thermosyphon Foundations in Warm Permafrost (Prepared for Government of the NT Asset Management Division Public Works and Services and Climate Change Vulnerability Assessment Canadian Council of Professional Engineers" (PDF). geocryology.files.wordpress.com.
  3. ^ . BTF Solar. 2007. Archived from the original on 17 Aug 2014. Retrieved 23 Jul 2021.
  4. ^ . apogee.net. Archived from the original on 3 Apr 2013. Retrieved 23 Jul 2021.
  5. ^ Haslego C (2010). "What is a Heat Pipe?". Cheresources.com Community.
  6. ^ Norton B (2011). "Solar Water Heaters: A Review of Systems Research and Design Innovation". Green. 1 (2): 189–207. doi:10.1515/green.2011.016. S2CID 138026949.
  7. ^ Wagner AM (2014). "Review of Thermosyphon Applications" (PDF). ERDC/CRREL TR-14-1. US Army Engineer Research and Development Center (ERDC). (PDF) from the original on June 25, 2021. Retrieved 24 Jun 2021.
  8. ^ Jorgenson MT, Shur YL, Pullman ER (2006). "Abrupt increase in permafrost degradation in Arctic Alaska". Geophysical Research Letters. 33 (2): L02503. Bibcode:2006GeoRL..33.2503J. doi:10.1029/2005GL024960.
  9. ^ . Alaska Climate Research Center (Chart from article). Geophysical Institute, University of Alaska Fairbanks. Archived from the original on 2021-09-09. Retrieved 2021-06-25. {{cite web}}: External link in |type= (help)
  10. ^ Kuemel B (2005). "CPU Vapor Cooling Thermosyphon". overclockers.com. Retrieved 26 Aug 2012.

External links Edit

  • HP Labs report on thermosiphons for computer cooling (PDF)

thermosiphon, this, article, includes, list, general, references, lacks, sufficient, corresponding, inline, citations, please, help, improve, this, article, introducing, more, precise, citations, march, 2009, learn, when, remove, this, template, message, therm. This article includes a list of general references but it lacks sufficient corresponding inline citations Please help to improve this article by introducing more precise citations March 2009 Learn how and when to remove this template message Thermosiphon or thermosyphon is a method of passive heat exchange based on natural convection which circulates a fluid without the necessity of a mechanical pump Thermosiphoning is used for circulation of liquids and volatile gases in heating and cooling applications such as heat pumps water heaters boilers and furnaces Thermosiphoning also occurs across air temperature gradients such as those utilized in a wood fire chimney or solar chimney Thermosyphon circulation in a simple solar water heater not a working model there is no water supply to replenish the tank when the tap is used This circulation can either be open loop as when the substance in a holding tank is passed in one direction via a heated transfer tube mounted at the bottom of the tank to a distribution point even one mounted above the originating tank or it can be a vertical closed loop circuit with return to the original container Its purpose is to simplify the transfer of liquid or gas while avoiding the cost and complexity of a conventional pump Contents 1 Simple thermosiphon 1 1 Heat pipes 1 2 Reboilers and calandria 2 Solar energy 3 Architecture 4 Computing 4 1 Uses 4 2 Drawbacks 5 Engine cooling 6 Espresso Machines 7 See also 8 References 9 External linksSimple thermosiphon EditNatural convection of the liquid starts when heat transfer to the liquid gives rise to a temperature difference from one side of the loop to the other The phenomenon of thermal expansion means that a temperature difference will have a corresponding difference in density across the loop The warmer fluid on one side of the loop is less dense and thus more buoyant than the cooler fluid on the other side The warmer fluid will float above the cooler fluid and the cooler fluid will sink below the warmer fluid This phenomenon of natural convection is known by the saying heat rises Convection moves the heated liquid upwards in the system as it is simultaneously replaced by cooler liquid returning by gravity A good thermosiphon has very little hydraulic resistance so that liquid can flow easily under the relatively low pressure produced by natural convection Heat pipes Edit Main article Heat pipe In some situations the flow of liquid may be reduced further or stopped perhaps because the loop is not entirely full of liquid In this case the system no longer convects so it is not a usual thermosiphon Heat can still be transferred in this system by the evaporation and condensation of vapor however the system is properly classified as a heat pipe thermosyphon 1 2 If the system also contains other fluids such as air then the heat flux density will be less than in a real heat pipe which contains only a single substance The thermosiphon has been sometimes incorrectly described as a gravity return heat pipe 3 Heat pipes usually have a wick to return the condensate to the evaporator via capillary action A wick is not needed in a thermosiphon because gravity moves the liquid 4 The wick allows heat pipes to transfer heat when there is no gravity which is useful in space A thermosiphon is simpler than a heat pipe 5 Single phase thermosiphons can only transfer heat upward or away from the acceleration vector Thus orientation is much more important for thermosiphons than for heatpipes Also thermosiphons can fail because of a bubble in the loop and require a circulating loop of pipes Reboilers and calandria Edit If the piping of a thermosiphon resists flow or excessive heat is applied the liquid may boil Since the gas is more buoyant than the liquid the convective pressure is greater This is a well known invention called a reboiler A group of reboilers attached to a pair of plena is called a calandria In some circumstances for example the cooling system for an older pre 1950s car the boiling of the fluid will cause the system to stop working as the volume of steam created displaces too much of the water and circulation stops The term phase change thermosiphon is a misnomer and should be avoided citation needed When phase change occurs in a thermosiphon it means that the system either does not have enough fluid or it is too small to transfer all of the heat by convection alone To improve the performance either more fluid is needed possibly in a larger thermosiphon or all other fluids including air should be pumped out of the loop Solar energy Edit nbsp Solar heating system featuring a thermosiphonThermosiphons are used in some liquid based solar heating systems to heat a liquid such as water The water is heated passively by solar energy and relies on heat energy being transferred from the sun to a solar collector The heat from the collector can be transferred to water in two ways directly where water circulates through the collector or indirectly where an anti freeze solution carries the heat from the collector and transfers it to water in the tank via a heat exchanger Convection allows for the movement of the heated liquid out of the solar collector to be replaced by colder liquid which is in turn heated Due to this principle it is necessary for the water to be stored in a tank above the collector 6 Architecture Edit nbsp Thermosiphon array at the Fairbanks International Airport used to chill the permafrost upon which the buildings of the airport are built The building foundations are at risk of dislocation if the permafrost thaws In locations historically dominated by permafrost conditions thermosiphons may be used to counter adverse geologic forces on the foundations of buildings pipelines and other structures caused by the thawing of the permafrost 7 A study published in 2006 by oil giant ConocoPhillips reports that Alaska s permafrost upon which much of the state s infrastructure is built has degraded since 1982 amid record warm temperatures 8 According to the Alaska Climate Research Center at the University of Alaska Fairbanks between 1949 and 2018 the average annual temperature in Alaska rose 4 0 degrees Fahrenheit with an increase of 7 2 degrees Fahrenheit over the winter 9 Computing EditThermosiphons are used for watercooling internal computer components 10 most commonly the processor While any suitable liquid can be used water is the easiest liquid to use in thermosiphon systems Unlike traditional watercooling systems thermosiphon systems do not rely on a pump but on convection for the movement of heated water which may become vapour from the components upwards to a heat exchanger There the water is cooled and is ready to be recirculated The most commonly used heat exchanger is a radiator where air is blown actively through a fan system to condense the vapour to a liquid The liquid is recirculated through the system thus repeating the process No pump is required The cycle of evaporation and condensation is driven by the difference in temperature Uses Edit Without proper cooling a modern processor chip can rapidly reach temperatures that cause it to malfunction Even with a common heat sink and fan attached typical processor operating temperatures may still reach up to 70 C 160 F A thermosiphon can efficiently transfer heat over a much wider temperature range and can typically maintain the processor temperature 10 20 C cooler than a traditional heat sink and fan In some cases it is also possible that a thermosiphon may cover multiple heat sources and design wise be more compact than an appropriately sized conventional heat sink and fan Drawbacks Edit Thermosiphons must be mounted such that vapor rises up and liquid flows down to the boiler with no bends in the tubing for liquid to pool Also the thermosiphon s fan that cools the gas needs cool air to operate The system has to be completely airtight if not the process of thermosiphon will not take effect and cause the water to only evaporate over a small period of time Engine cooling Edit nbsp 1937 diagram of engine cooling entirely by thermosiphon circulationSome early cars motor vehicles and engine powered farm and industrial equipment used thermosiphon circulation to move cooling water between their cylinder block and radiator This method of water circulation depends on keeping enough cool air moving past the radiator to provide a sufficient temperature differential the air movement was accomplished by the forward motion of the vehicle and by the use of fans As engine power increased increased flow of water was required so engine driven pumps were added to assist circulation More compact engines began to use smaller radiators and require more convoluted flow patterns so the water circulation became entirely dependent on the pump and might even be reversed against its natural direction An engine that circulates its cooling water only by thermosiphon is susceptible to overheating during prolonged periods of idling or very slow travel since the lack of forward motion provides too little airflow past the radiator unless one or more fans are able to move enough air by themselves Thermosiphon systems are also very sensitive to low coolant level i e losing only a small amount of coolant stops the circulation a pump driven system is much more robust and can typically handle a lower coolant level Espresso Machines EditMany espresso machine designs use a thermosiphon in order to maintain a stable temperature The iconic E 61 espresso machine has a group head with a thermosiphon This group head is common on many espresso machines today Some lever espresso machines have a double wall around the piston in their group that is used for a thermosiphon A modern example would be the machines from Londinium See also Edit nbsp Wikimedia Commons has media related to Thermosiphons Convection Geothermal heat pump Heat pipe and Loop heat pipe Passive solar Reboiler Siphon Solar heating Thermic siphon Vapor compression refrigeration Watercooling Thomas Fowler inventor References Edit Thermosyphon technology for Artificial Ground Freezing AGF simmakers com Simmakers Ltd 2017 Archived from the original on 5 Mar 2021 Retrieved 23 Jan 2021 Holubec I 2008 Flat Loop Thermosyphon Foundations in Warm Permafrost Prepared for Government of the NT Asset Management Division Public Works and Services and Climate Change Vulnerability Assessment Canadian Council of Professional Engineers PDF geocryology files wordpress com Evacuated Tube Heat Pipe Principles BTF Solar 2007 Archived from the original on 17 Aug 2014 Retrieved 23 Jul 2021 Thermosiphon Heat Exchangers apogee net Archived from the original on 3 Apr 2013 Retrieved 23 Jul 2021 Haslego C 2010 What is a Heat Pipe Cheresources com Community Norton B 2011 Solar Water Heaters A Review of Systems Research and Design Innovation Green 1 2 189 207 doi 10 1515 green 2011 016 S2CID 138026949 Wagner AM 2014 Review of Thermosyphon Applications PDF ERDC CRREL TR 14 1 US Army Engineer Research and Development Center ERDC Archived PDF from the original on June 25 2021 Retrieved 24 Jun 2021 Jorgenson MT Shur YL Pullman ER 2006 Abrupt increase in permafrost degradation in Arctic Alaska Geophysical Research Letters 33 2 L02503 Bibcode 2006GeoRL 33 2503J doi 10 1029 2005GL024960 Total Change in Mean Seasonal and Annual Temperature F 1949 2018 Alaska Climate Research Center Chart from article Geophysical Institute University of Alaska Fairbanks Archived from the original on 2021 09 09 Retrieved 2021 06 25 a href Template Cite web html title Template Cite web cite web a External link in code class cs1 code type code help Kuemel B 2005 CPU Vapor Cooling Thermosyphon overclockers com Retrieved 26 Aug 2012 External links EditHP Labs report on thermosiphons for computer cooling PDF Retrieved from https en wikipedia org w index php title Thermosiphon amp oldid 1173470336, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.