Infrared thermography (IRT), thermal video and/or thermal imaging, is a process where a thermal camera captures and creates an image of an object by using infrared radiation emitted from the object in a process, which are examples of infrared imaging science. Thermographic cameras usually detect radiation in the long-infrared range of the electromagnetic spectrum (roughly 9,000–14,000 nanometers or 9–14 μm) and produce images of that radiation, called thermograms. Since infrared radiation is emitted by all objects with a temperature above absolute zero according to the black body radiation law, thermography makes it possible to see one's environment with or without visible illumination. The amount of radiation emitted by an object increases with temperature; therefore, thermography allows one to see variations in temperature. When viewed through a thermal imaging camera, warm objects stand out well against cooler backgrounds; humans and other warm-blooded animals become easily visible against the environment, day or night. As a result, thermography is particularly useful to the military and other users of surveillance cameras.

Thermogram of a traditional building in the background and a "passive house" in the foreground
Thermogram of a cat

Some physiological changes in human beings and other warm-blooded animals can also be monitored with thermal imaging during clinical diagnostics. Thermography is used in allergy detection and veterinary medicine. Some alternative medicine practitioners promote its use for breast screening, despite the FDA warning that "those who opt for this method instead of mammography may miss the chance to detect cancer at its earliest stage".[1] Government and airport personnel used thermography to detect suspected swine flu cases during the 2009 pandemic.[2]

Thermal imaging camera and screen. Thermal imaging can detect elevated body temperature, one of the signs of the virus H1N1 (swine influenza).

Thermography has a long history, although its use has increased dramatically with the commercial and industrial applications of the past fifty years. Firefighters use thermography to see through smoke, to find persons, and to localize the base of a fire. Maintenance technicians use thermography to locate overheating joints and sections of power lines, which are a sign of impending failure. Building construction technicians can see thermal signatures that indicate heat leaks in faulty thermal insulation and can use the results to improve the efficiency of heating and air-conditioning units.

The appearance and operation of a modern thermographic camera is often similar to a camcorder. Often the live thermogram reveals temperature variations so clearly that a photograph is not necessary for analysis. A recording module is therefore not always built-in.

Specialized thermal imaging cameras use focal plane arrays (FPAs) that respond to longer wavelengths (mid- and long-wavelength infrared). The most common types are InSb, InGaAs, HgCdTe and QWIP FPA. The newest technologies use low-cost, uncooled microbolometers as FPA sensors. Their resolution is considerably lower than that of optical cameras, mostly 160x120 or 320x240 pixels, up to 1280 x 1024[3] for the most expensive models. Thermal imaging cameras are much more expensive than their visible-spectrum counterparts, and higher-end models are often export-restricted due to the military uses for this technology. Older bolometers or more sensitive models such as InSb require cryogenic cooling, usually by a miniature Stirling cycle refrigerator or liquid nitrogen.

Thermal energy edit

 
 
A comparison of a thermal image (top) and an ordinary photograph (bottom). The plastic bag is mostly transparent to long-wavelength infrared, but the man's glasses are opaque.
 
This thermogram shows excessive heating on a terminal in an industrial electrical fuse block.

Thermal images, or thermograms, are actually visual displays of the amount of infrared energy emitted, transmitted, and reflected by an object. Because there are multiple sources of the infrared energy, it is difficult to get an accurate temperature of an object using this method. A thermal imaging camera is capable of performing algorithms to interpret that data and build an image. Although the image shows the viewer an approximation of the temperature at which the object is operating, the camera is actually using multiple sources of data based on the areas surrounding the object to determine that value rather than detecting the actual temperature.[4]

This phenomenon may become clearer upon consideration of the formula:

Incident Radiant Power = Emitted Radiant Power + Transmitted Radiant Power + Reflected Radiant Power;

where incident radiant power is the radiant power profile when viewed through a thermal imaging camera. Emitted radiant power is generally what is intended to be measured; transmitted radiant power is the radiant power that passes through the subject from a remote thermal source, and; reflected radiant power is the amount of radiant power that reflects off the surface of the object from a remote thermal source.

This phenomenon occurs everywhere, all the time. It is a process known as radiant heat exchange, since radiant power × time equals radiant energy. However, in the case of infrared thermography, the above equation is used to describe the radiant power within the spectral wavelength passband of the thermal imaging camera in use. The radiant heat exchange requirements described in the equation apply equally at every wavelength in the electromagnetic spectrum.

If the object is radiating at a higher temperature than its surroundings, then power transfer will be taking place and power will be radiating from warm to cold following the principle stated in the second law of thermodynamics. So if there is a cool area in the thermogram, that object will be absorbing the radiation emitted by the warm object.

The ability of objects to emit is called emissivity, to absorb radiation is called absorptivity. Under outdoor environments, convective cooling from wind may also need to be considered when trying to get an accurate temperature reading.

The thermal imaging camera would next employ a series of mathematical algorithms. Since the camera is only able to see the electromagnetic radiation that is impossible to detect with the human eye, it will build a picture in the viewer and record a visible picture, usually in a JPG format.

In order to perform the role of non-contact temperature recorder, the camera will change the temperature of the object being viewed with its emissivity setting.

Other algorithms can be used to affect the measurement, including the transmission ability of the transmitting medium (usually air) and the temperature of that transmitting medium. All these settings will affect the ultimate output for the temperature of the object being viewed.

This functionality makes the thermal imaging camera an excellent tool for the maintenance of electrical and mechanical systems in industry and commerce. By using the proper camera settings and by being careful when capturing the image, electrical systems can be scanned and problems can be found. Faults with steam traps in steam heating systems are easy to locate.

In the energy savings area, the thermal imaging camera can do more. Because it can see the effective radiation temperature of an object as well as what that object is radiating towards, it can help locate sources of thermal leaks and overheated regions as well.

Emissivity edit

Emissivity is a term that is often misunderstood and misused. It represents a material's ability to emit thermal radiation and is an optical property of matter.

Each material has a different emissivity, which may vary by temperature and infrared wavelength.[5] For example, clean metal surfaces have emissivity that decreases at longer wavelengths; many dielectric materials, such as quartz (SiO2), sapphire (Al2O3), calcium fluoride (CaF2), etc. have emissivity that increases at longer wavelength; simple oxides, such as iron oxide (Fe2O3) display relatively flat emissivity in the infrared spectrum.

A material's emissivity can range from a theoretical 0.00 (completely not-emitting) to an equally theoretical 1.00 (completely emitting). An example of a substance with low emissivity would be silver, with an emissivity coefficient of .02. An example of a substance with high emissivity would be asphalt, with an emissivity coefficient of .98.

A black body is a theoretical object with an emissivity of 1 that radiates thermal radiation characteristic of its contact temperature. That is, if the contact temperature of a thermally uniform black body radiator were 50 °C (122 °F), the black body would emit thermal radiation characteristic of 50 °C (122 °F).

 
Thermogram of a snake held by a human

An ordinary object emits less infrared radiation than a theoretical black body. The fraction of its actual emission to the theoretical emission (of the black body) is its emissivity (or emissivity coefficient).

In order to make a temperature measurement of an object using an infrared imager, it is necessary to estimate or determine the object's emissivity. For quick work, a thermographer may refer to an emissivity table for a given type of object, and enter that value into the imager. The imager would then calculate the object's contact temperature based on the value entered from the table and the object's emission of infrared radiation as detected by the imager.

In order to get a more accurate temperature measurement, a thermographer may apply a standard material of known, high emissivity to the surface of the object. The standard material might be as complex as industrial emissivity spray produced specifically for the purpose, or as simple as standard black insulation tape, with an emissivity of about 0.97. The object's known temperature can then be measured using the standard emissivity. If desired, the object's actual emissivity (on a part of the object that is not covered by the standard material) can then be determined by adjusting the imager's setting to the known temperature. There are situations, however, when such an emissivity test is not possible due to dangerous or inaccessible conditions. In these situations, the thermographer must rely on tables.

Difference from infrared film edit

IR film is sensitive to infrared (IR) radiation in the 250 to 500 °C (482 to 932 °F) range, while the range of thermography is approximately −50 to 2,000 °C (−58 to 3,632 °F). So, for an IR film to work thermographically, it must be over 250 °C (482 °F) or be reflecting infrared radiation from something that is at least that hot.

Night vision infrared devices image in the near-infrared, just beyond the visual spectrum, and can see emitted or reflected near-infrared in complete visual darkness. However, again, these are not usually used for thermography due to the high temperature requirements, but are instead used with active near-IR sources.

Starlight-type night vision devices generally only magnify ambient light.

Passive vs. active thermography edit

All objects above the absolute zero temperature (0 K) emit infrared radiation. Hence, an excellent way to measure thermal variations is to use an infrared vision device, usually a focal plane array (FPA) infrared camera capable of detecting radiation in the mid (3 to 5 μm) and long (7 to 14 μm) wave infrared bands, denoted as MWIR and LWIR, corresponding to two of the high transmittance infrared windows. Abnormal temperature profiles at the surface of an object are an indication of a potential problem.[6]

In passive thermography, the features of interest are naturally at a higher or lower temperature than the background. Passive thermography has many applications such as surveillance of people on a scene and medical diagnosis (specifically thermology).

In active thermography, an energy source is required to produce a thermal contrast between the feature of interest and the background. The active approach is necessary in many cases given that the inspected parts are usually in equilibrium with the surroundings. Given the super-linearities of the black-body radiation, active thermography can also be used to enhance the resolution of imaging systems beyond their diffraction limit or to achieve super-resolution microscopy.[7]

Advantages edit

It shows a visual picture so temperatures over a large area can be compared.[8][9][10] It is capable of catching moving targets in real time.[8][9][10] It is able to find deterioration, i.e., higher temperature components prior to their failure. It can be used to measure or observe in areas inaccessible or hazardous for other methods. It is a non-destructive test method. It can be used to find defects in shafts, pipes, and other metal or plastic parts.[11] It can be used to detect objects in dark areas. It has some medical application, essentially in physiotherapy.

Limitations and disadvantages edit

There are various cameras cheaper and more expensive. Quality cameras often have a high price range (often US$3,000 or more) due to the expense of the larger pixel array (state of the art 1280 x 1024), while less expensive models (with pixel arrays of 40x40 up to 160x120 pixels) are also available. Fewer pixels reduce the image quality making it more difficult to distinguish proximate targets within the same field of view.

There is also a difference in refresh rate. Some cameras may only have a refreshing value of 5 –15 Hz, other (e.g. FLIR X8500sc[3]) 180 Hz or even more in no full window mode.

Also the lens can be integrated or not.

Many models do not provide the irradiance measurements used to construct the output image; the loss of this information without a correct calibration for emissivity, distance, and ambient temperature and relative humidity entails that the resultant images are inherently incorrect measurements of temperature.[12]

Images can be difficult to interpret accurately when based upon certain objects, specifically objects with erratic temperatures, although this problem is reduced in active thermal imaging.[13]

Thermographic cameras create thermal images based on the radiant heat energy it receives.[14] As radiation levels are influenced by the emissivity and reflection of radiation such as sunlight from the surface being measured this causes errors in the measurements.[15]

  • Most cameras have ±2% accuracy or worse in measurement of temperature and are not as accurate as contact methods.[8][9][10]
  • Methods and instruments are limited to directly detecting surface temperatures.

Applications edit

 
Kite aerial thermogram revealing features on/under a grassed playing field. Thermal inertia and differential transpiration/evaporation are involved
 
UAS thermal imagery of a solar panel array in Switzerland
 
AN/PAS-13 thermal rifle scope mounted on an AR-15 rifle

Thermal imaging cameras convert the energy in the infrared wavelength into a visible light display. All objects above absolute zero emit thermal infrared energy, so thermal cameras can passively see all objects, regardless of ambient light. However, most thermal cameras only see objects warmer than −50 °C (−58 °F).

The spectrum and amount of thermal radiation depend strongly on an object's surface temperature. This makes it possible for a thermal imaging camera to display an object's temperature. However, other factors also influence the radiation, which limits the accuracy of this technique. For example, the radiation depends not only on the temperature of the object, but is also a function of the emissivity of the object. Also, radiation originates from the surroundings and is reflected in the object, and the radiation from the object and the reflected radiation will also be influenced by the absorption of the atmosphere.

Standards edit

ASTM International (ASTM)
  • ASTM C1060, Standard Practice for Thermographic Inspection of Insulation Installations in Envelope Cavities of Frame Buildings
  • ASTM C1153, Standard Practice for the Location of Wet Insulation in Roofing Systems Using Infrared Imaging
  • ATSM D4788, Standard Test Method for Detecting Delamination in Bridge Decks Using Infrared Thermography
  • ASTM E1186, Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems
  • ASTM E1934, Standard Guide for Examining Electrical and Mechanical Equipment with Infrared Thermography
International Organization for Standardization (ISO)
  • ISO 6781, Thermal insulation – Qualitative detection of thermal irregularities in building envelopes – Infrared method
  • ISO 18434-1, Condition monitoring and diagnostics of machines – Thermography – Part 1: General procedures
  • ISO 18436-7, Condition monitoring and diagnostics of machines – Requirements for qualification and assessment of personnel – Part 7: Thermography

Biological counterpart edit

Thermography by definition is by means of an instrument (artifact), but some living creatures have natural organs that function as counterparts to bolometers, and thus possess a crude type of thermal imaging capability (thermoception). One of the best known examples is infrared sensing in snakes.

CCD and CMOS thermography edit

 
Color contours of temperature for a smoldering ember measured with a CMOS camera.

Non-specialized CCD and CMOS sensors have most of their spectral sensitivity in the visible light wavelength range. However, by utilizing the "trailing" area of their spectral sensitivity, namely the part of the infrared spectrum called near-infrared (NIR), and by using off-the-shelf CCTV camera it is possible under certain circumstances to obtain true thermal images of objects with temperatures at about 280 °C (536 °F) and higher.[27]

At temperatures of 600 °C and above, inexpensive cameras with CCD and CMOS sensors have also been used for pyrometry in the visible spectrum. They have been used for soot in flames, burning coal particles, heated materials, SiC filaments, and smoldering embers.[28] This pyrometry has been performed using external filters or only the sensor's Bayer filters. It has been performed using color ratios, grayscales, and/or a hybrid of both.

See also edit

References edit

  1. ^ "Breast Cancer Screening: Thermogram No Substitute for Mammogram". fda.gov. US Food and Drug Administration. 27 October 2017. from the original on 23 June 2018. Retrieved 23 June 2018.
  2. ^ . applegate.co.uk. 29 April 2009. Archived from the original on 29 February 2012. Retrieved 18 June 2013.
  3. ^ a b FLIR x8500sc Thermal imaging camera specifications. Retrieved on 2019-07-10.
  4. ^ . thermalscope.com. Archived from the original on 8 November 2014. Retrieved 31 October 2014.
  5. ^ Hapke B (19 January 2012). Theory of Reflectance and Emittance Spectroscopy. Cambridge University Press. p. 416. ISBN 978-0-521-88349-8.
  6. ^ Maldague XP, Jones TS, Kaplan H, Marinetti S, Prystay M (2001). "Fundamentals of infrared and thermal testing.". In Maldague K, Moore PO (eds.). Nondestructive Handbook, Infrared and Thermal Testing z÷÷÷÷. Vol. 3 (3rd ed.). Columbus, Ohio: ASNT Press.
  7. ^ Graciani G, Amblard F (December 2019). "Super-resolution provided by the arbitrarily strong superlinearity of the blackbody radiation". Nature Communications. 10 (1): 5761. Bibcode:2019NatCo..10.5761G. doi:10.1038/s41467-019-13780-4. PMC 6917796. PMID 31848354.
  8. ^ a b c Costello JT, McInerney CD, Bleakley CM, Selfe J, Donnelly AE (2012-02-01). "The use of thermal imaging in assessing skin temperature following cryotherapy: a review" (PDF). Journal of Thermal Biology. 37 (2): 103–110. doi:10.1016/j.jtherbio.2011.11.008.
  9. ^ a b c Bach AJ, Stewart IB, Minett GM, Costello JT (September 2015). "Does the technique employed for skin temperature assessment alter outcomes? A systematic review" (PDF). Physiological Measurement. 36 (9): R27-51. Bibcode:2015PhyM...36R..27B. doi:10.1088/0967-3334/36/9/r27. PMID 26261099. S2CID 23259170.
  10. ^ a b c Bach AJ, Stewart IB, Disher AE, Costello JT (2015-02-06). "A comparison between conductive and infrared devices for measuring mean skin temperature at rest, during exercise in the heat, and recovery". PLOS ONE. 10 (2): e0117907. Bibcode:2015PLoSO..1017907B. doi:10.1371/journal.pone.0117907. PMC 4319934. PMID 25659140.
  11. ^ Using Thermography to Find a Class of Latent Construction Defects. Globalspec.com. Retrieved on 2013-06-18.
  12. ^ F. Colbert, "Looking Under the Hood: Converting Proprietary Image File Formats Created within IR Cameras for Improved Archival Use", Professional Thermographers Association
  13. ^ Infrared Temperature Theory and Application. Omega.com. Retrieved on 2013-06-18.
  14. ^ "IR scanning handbook" (PDF). Nhatha. NETA. Retrieved 22 June 2019.
  15. ^ Real Time Emissivity Measurement for Infrared Temperature Measurement. Pyrometer.com. Retrieved on 2013-06-18.
  16. ^ Kylili A, Fokaides PA, Christou P, Kalogirou SA (2014). "Infrared thermography (IRT) applications for building diagnostics: A review". Applied Energy. 134: 531–549. doi:10.1016/j.apenergy.2014.08.005.
  17. ^ Saxena, A; Ng, EYK; Lim, ST (October 2019). "Infrared (IR) thermography as a potential screening modality for carotid artery stenosis". Computers in Biology and Medicine. 113: 103419. doi:10.1016/j.compbiomed.2019.103419. PMID 31493579. S2CID 202003120.
  18. ^ Saxena, Ashish; Raman, Vignesh; Ng, E. Y. K. (2 October 2019). "Study on methods to extract high contrast image in active dynamic thermography". Quantitative InfraRed Thermography Journal. 16 (3–4): 243–259. doi:10.1080/17686733.2019.1586376. hdl:10356/144497. S2CID 141334526.
  19. ^ Saxena, A; Ng, EYK; Lim, ST (May 2020). "Active dynamic thermography to detect the presence of stenosis in the carotid artery". Computers in Biology and Medicine. 120: 103718. doi:10.1016/j.compbiomed.2020.103718. PMID 32250851. S2CID 215408087.
  20. ^ Saxena, Ashish; Ng, E.Y.K.; Raman, Vignesh; Syarifuddin Bin Mohamed Hamli, Muhammad; Moderhak, Mateusz; Kolacz, Szymon; Jankau, Jerzy (December 2019). "Infrared (IR) thermography-based quantitative parameters to predict the risk of post-operative cancerous breast resection flap necrosis". Infrared Physics & Technology. 103: 103063. Bibcode:2019InPhT.10303063S. doi:10.1016/j.infrared.2019.103063. S2CID 209285015.
  21. ^ Soroko M, Morel MC (2016). Equine thermography in practice. Wallingford - Boston: CABI. ISBN 9781780647876. LCCN 2016935227.
  22. ^ Morgan Hughes; Paul Hopwood; Matilda Dolan; Ben Dolan (4 October 2022). "Applications of thermal imaging for bird surveys: examples from the field". Ringing and Migration: 1–4. doi:10.1080/03078698.2022.2123026. ISSN 0307-8698. Wikidata Q114456608.
  23. ^ Gaszczak A, Breckon TP, Han J (2011). Röning J, Casasent DP, Hall EL (eds.). "Real-time People and Vehicle Detection from UAV Imagery". Proc. SPIE Conference Intelligent Robots and Computer Vision XXVIII: Algorithms and Techniques. Intelligent Robots and Computer Vision XXVIII: Algorithms and Techniques. 7878: 78780B. Bibcode:2011SPIE.7878E..0BG. CiteSeerX 10.1.1.188.4657. doi:10.1117/12.876663. hdl:1826/7589. S2CID 18710932.
  24. ^ Pinggera P, Breckon TF, Bischof H (2012). "On Cross-Spectral Stereo Matching using Dense Gradient Features". Proceedings of the British Machine Vision Conference 2012. BMVA. pp. 526.1–526.12. doi:10.5244/C.26.103. ISBN 978-1-901725-46-9. {{cite book}}: |journal= ignored (help)[dead link]
  25. ^ Thermographic images in active volcanoes surveillance system — TIIMNet project Vesuvius and Solfatara INGV Naples Italy Archived 2012-07-10 at archive.today. Ipf.ov.ingv.it. Retrieved on 2013-06-18.
  26. ^ Infrared Building Inspections — Resources for Electrical, Mechanical, Residential and Commercial Infrared/Thermal Inspections 2018-08-06 at the Wayback Machine. Infrared-buildinginspections.com (2008-09-04). Retrieved on 2013-06-18.
  27. ^ Porev VA, Porev GV (2004). "Experimental determination of the temperature range of a television pyrometer". Journal of Optical Technology. 71 (1): 70–71. Bibcode:2004JOptT..71...62P. doi:10.1364/JOT.71.000062.
  28. ^ Kim, Dennis K.; Sunderland, Peter B. (2019). "Fire Ember Pyrometry Using a Color Camera (2019)". Fire Safety Journal. 106: 88–93. doi:10.1016/j.firesaf.2019.04.006. S2CID 145942969.

External links edit

  • Infrared Tube, infrared imaging science demonstrations
  • , Some uses of thermographic images in electronics
  • Thermographic Images, Infrared pictures
  • by Lawrence Mayes
  • Archaeological aerial thermography
  • IR Thermometry & Thermography Applications Repository , IR Thermometry & Thermography Applications Repository

thermography, this, article, about, infrared, imaging, technique, printing, technique, called, thermography, thermographic, printing, thermography, medicine, contact, thermography, been, suggested, that, thermographic, camera, merged, into, this, article, disc. This article is about the infrared imaging technique For the printing technique called thermography see thermographic printing For thermography in medicine see Non contact thermography It has been suggested that Thermographic camera be merged into this article Discuss Proposed since November 2023 Infrared thermography IRT thermal video and or thermal imaging is a process where a thermal camera captures and creates an image of an object by using infrared radiation emitted from the object in a process which are examples of infrared imaging science Thermographic cameras usually detect radiation in the long infrared range of the electromagnetic spectrum roughly 9 000 14 000 nanometers or 9 14 mm and produce images of that radiation called thermograms Since infrared radiation is emitted by all objects with a temperature above absolute zero according to the black body radiation law thermography makes it possible to see one s environment with or without visible illumination The amount of radiation emitted by an object increases with temperature therefore thermography allows one to see variations in temperature When viewed through a thermal imaging camera warm objects stand out well against cooler backgrounds humans and other warm blooded animals become easily visible against the environment day or night As a result thermography is particularly useful to the military and other users of surveillance cameras Thermogram of a traditional building in the background and a passive house in the foreground Thermogram of a catSome physiological changes in human beings and other warm blooded animals can also be monitored with thermal imaging during clinical diagnostics Thermography is used in allergy detection and veterinary medicine Some alternative medicine practitioners promote its use for breast screening despite the FDA warning that those who opt for this method instead of mammography may miss the chance to detect cancer at its earliest stage 1 Government and airport personnel used thermography to detect suspected swine flu cases during the 2009 pandemic 2 Thermal imaging camera and screen Thermal imaging can detect elevated body temperature one of the signs of the virus H1N1 swine influenza Thermography has a long history although its use has increased dramatically with the commercial and industrial applications of the past fifty years Firefighters use thermography to see through smoke to find persons and to localize the base of a fire Maintenance technicians use thermography to locate overheating joints and sections of power lines which are a sign of impending failure Building construction technicians can see thermal signatures that indicate heat leaks in faulty thermal insulation and can use the results to improve the efficiency of heating and air conditioning units The appearance and operation of a modern thermographic camera is often similar to a camcorder Often the live thermogram reveals temperature variations so clearly that a photograph is not necessary for analysis A recording module is therefore not always built in Specialized thermal imaging cameras use focal plane arrays FPAs that respond to longer wavelengths mid and long wavelength infrared The most common types are InSb InGaAs HgCdTe and QWIP FPA The newest technologies use low cost uncooled microbolometers as FPA sensors Their resolution is considerably lower than that of optical cameras mostly 160x120 or 320x240 pixels up to 1280 x 1024 3 for the most expensive models Thermal imaging cameras are much more expensive than their visible spectrum counterparts and higher end models are often export restricted due to the military uses for this technology Older bolometers or more sensitive models such as InSb require cryogenic cooling usually by a miniature Stirling cycle refrigerator or liquid nitrogen Contents 1 Thermal energy 2 Emissivity 3 Difference from infrared film 4 Passive vs active thermography 5 Advantages 6 Limitations and disadvantages 7 Applications 8 Standards 9 Biological counterpart 10 CCD and CMOS thermography 11 See also 12 References 13 External linksThermal energy editThis article needs additional citations for verification Please help improve this article by adding citations to reliable sources Unsourced material may be challenged and removed Find sources Thermography news newspapers books scholar JSTOR July 2008 Learn how and when to remove this template message nbsp nbsp A comparison of a thermal image top and an ordinary photograph bottom The plastic bag is mostly transparent to long wavelength infrared but the man s glasses are opaque nbsp This thermogram shows excessive heating on a terminal in an industrial electrical fuse block Thermal images or thermograms are actually visual displays of the amount of infrared energy emitted transmitted and reflected by an object Because there are multiple sources of the infrared energy it is difficult to get an accurate temperature of an object using this method A thermal imaging camera is capable of performing algorithms to interpret that data and build an image Although the image shows the viewer an approximation of the temperature at which the object is operating the camera is actually using multiple sources of data based on the areas surrounding the object to determine that value rather than detecting the actual temperature 4 This phenomenon may become clearer upon consideration of the formula Incident Radiant Power Emitted Radiant Power Transmitted Radiant Power Reflected Radiant Power where incident radiant power is the radiant power profile when viewed through a thermal imaging camera Emitted radiant power is generally what is intended to be measured transmitted radiant power is the radiant power that passes through the subject from a remote thermal source and reflected radiant power is the amount of radiant power that reflects off the surface of the object from a remote thermal source This phenomenon occurs everywhere all the time It is a process known as radiant heat exchange since radiant power time equals radiant energy However in the case of infrared thermography the above equation is used to describe the radiant power within the spectral wavelength passband of the thermal imaging camera in use The radiant heat exchange requirements described in the equation apply equally at every wavelength in the electromagnetic spectrum If the object is radiating at a higher temperature than its surroundings then power transfer will be taking place and power will be radiating from warm to cold following the principle stated in the second law of thermodynamics So if there is a cool area in the thermogram that object will be absorbing the radiation emitted by the warm object The ability of objects to emit is called emissivity to absorb radiation is called absorptivity Under outdoor environments convective cooling from wind may also need to be considered when trying to get an accurate temperature reading The thermal imaging camera would next employ a series of mathematical algorithms Since the camera is only able to see the electromagnetic radiation that is impossible to detect with the human eye it will build a picture in the viewer and record a visible picture usually in a JPG format In order to perform the role of non contact temperature recorder the camera will change the temperature of the object being viewed with its emissivity setting Other algorithms can be used to affect the measurement including the transmission ability of the transmitting medium usually air and the temperature of that transmitting medium All these settings will affect the ultimate output for the temperature of the object being viewed This functionality makes the thermal imaging camera an excellent tool for the maintenance of electrical and mechanical systems in industry and commerce By using the proper camera settings and by being careful when capturing the image electrical systems can be scanned and problems can be found Faults with steam traps in steam heating systems are easy to locate In the energy savings area the thermal imaging camera can do more Because it can see the effective radiation temperature of an object as well as what that object is radiating towards it can help locate sources of thermal leaks and overheated regions as well Emissivity editEmissivity is a term that is often misunderstood and misused It represents a material s ability to emit thermal radiation and is an optical property of matter Each material has a different emissivity which may vary by temperature and infrared wavelength 5 For example clean metal surfaces have emissivity that decreases at longer wavelengths many dielectric materials such as quartz SiO2 sapphire Al2O3 calcium fluoride CaF2 etc have emissivity that increases at longer wavelength simple oxides such as iron oxide Fe2O3 display relatively flat emissivity in the infrared spectrum A material s emissivity can range from a theoretical 0 00 completely not emitting to an equally theoretical 1 00 completely emitting An example of a substance with low emissivity would be silver with an emissivity coefficient of 02 An example of a substance with high emissivity would be asphalt with an emissivity coefficient of 98 A black body is a theoretical object with an emissivity of 1 that radiates thermal radiation characteristic of its contact temperature That is if the contact temperature of a thermally uniform black body radiator were 50 C 122 F the black body would emit thermal radiation characteristic of 50 C 122 F nbsp Thermogram of a snake held by a humanAn ordinary object emits less infrared radiation than a theoretical black body The fraction of its actual emission to the theoretical emission of the black body is its emissivity or emissivity coefficient In order to make a temperature measurement of an object using an infrared imager it is necessary to estimate or determine the object s emissivity For quick work a thermographer may refer to an emissivity table for a given type of object and enter that value into the imager The imager would then calculate the object s contact temperature based on the value entered from the table and the object s emission of infrared radiation as detected by the imager In order to get a more accurate temperature measurement a thermographer may apply a standard material of known high emissivity to the surface of the object The standard material might be as complex as industrial emissivity spray produced specifically for the purpose or as simple as standard black insulation tape with an emissivity of about 0 97 The object s known temperature can then be measured using the standard emissivity If desired the object s actual emissivity on a part of the object that is not covered by the standard material can then be determined by adjusting the imager s setting to the known temperature There are situations however when such an emissivity test is not possible due to dangerous or inaccessible conditions In these situations the thermographer must rely on tables Difference from infrared film editIR film is sensitive to infrared IR radiation in the 250 to 500 C 482 to 932 F range while the range of thermography is approximately 50 to 2 000 C 58 to 3 632 F So for an IR film to work thermographically it must be over 250 C 482 F or be reflecting infrared radiation from something that is at least that hot Night vision infrared devices image in the near infrared just beyond the visual spectrum and can see emitted or reflected near infrared in complete visual darkness However again these are not usually used for thermography due to the high temperature requirements but are instead used with active near IR sources Starlight type night vision devices generally only magnify ambient light Passive vs active thermography editAll objects above the absolute zero temperature 0 K emit infrared radiation Hence an excellent way to measure thermal variations is to use an infrared vision device usually a focal plane array FPA infrared camera capable of detecting radiation in the mid 3 to 5 mm and long 7 to 14 mm wave infrared bands denoted as MWIR and LWIR corresponding to two of the high transmittance infrared windows Abnormal temperature profiles at the surface of an object are an indication of a potential problem 6 In passive thermography the features of interest are naturally at a higher or lower temperature than the background Passive thermography has many applications such as surveillance of people on a scene and medical diagnosis specifically thermology In active thermography an energy source is required to produce a thermal contrast between the feature of interest and the background The active approach is necessary in many cases given that the inspected parts are usually in equilibrium with the surroundings Given the super linearities of the black body radiation active thermography can also be used to enhance the resolution of imaging systems beyond their diffraction limit or to achieve super resolution microscopy 7 Advantages editIt shows a visual picture so temperatures over a large area can be compared 8 9 10 It is capable of catching moving targets in real time 8 9 10 It is able to find deterioration i e higher temperature components prior to their failure It can be used to measure or observe in areas inaccessible or hazardous for other methods It is a non destructive test method It can be used to find defects in shafts pipes and other metal or plastic parts 11 It can be used to detect objects in dark areas It has some medical application essentially in physiotherapy Limitations and disadvantages editThere are various cameras cheaper and more expensive Quality cameras often have a high price range often US 3 000 or more due to the expense of the larger pixel array state of the art 1280 x 1024 while less expensive models with pixel arrays of 40x40 up to 160x120 pixels are also available Fewer pixels reduce the image quality making it more difficult to distinguish proximate targets within the same field of view There is also a difference in refresh rate Some cameras may only have a refreshing value of 5 15 Hz other e g FLIR X8500sc 3 180 Hz or even more in no full window mode Also the lens can be integrated or not Many models do not provide the irradiance measurements used to construct the output image the loss of this information without a correct calibration for emissivity distance and ambient temperature and relative humidity entails that the resultant images are inherently incorrect measurements of temperature 12 Images can be difficult to interpret accurately when based upon certain objects specifically objects with erratic temperatures although this problem is reduced in active thermal imaging 13 Thermographic cameras create thermal images based on the radiant heat energy it receives 14 As radiation levels are influenced by the emissivity and reflection of radiation such as sunlight from the surface being measured this causes errors in the measurements 15 Most cameras have 2 accuracy or worse in measurement of temperature and are not as accurate as contact methods 8 9 10 Methods and instruments are limited to directly detecting surface temperatures Applications edit nbsp Kite aerial thermogram revealing features on under a grassed playing field Thermal inertia and differential transpiration evaporation are involved nbsp UAS thermal imagery of a solar panel array in Switzerland nbsp AN PAS 13 thermal rifle scope mounted on an AR 15 rifleCondition monitoring Low slope and flat roofing inspections Building diagnostics including building envelope inspections moisture inspections and energy losses in buildings 16 Thermal mapping Digital infrared thermal imaging in health care Medical imaging Non contact thermography contact thermography and dynamic angiothermography Peripheral vascular disease screening Carotid artery stenosis CAS screening through skin thermal maps 17 Active Dynamic Thermography ADT for medical applications 18 19 20 Neuromusculoskeletal disorders Extracranial cerebral and facial vascular disease Thyroid gland abnormalities Various other neoplastic metabolic and inflammatory conditions Archaeological kite aerial thermography Thermology Veterinary Thermal Imaging 21 Thermal imaging in ornithology and other wildlife monitoring 22 Night vision and Targeting UAV Surveillance 23 Stereo vision 24 Research Process control Nondestructive testing Surveillance in security law enforcement and defence Chemical imaging Volcanology 25 Building 26 Thermal imaging cameras convert the energy in the infrared wavelength into a visible light display All objects above absolute zero emit thermal infrared energy so thermal cameras can passively see all objects regardless of ambient light However most thermal cameras only see objects warmer than 50 C 58 F The spectrum and amount of thermal radiation depend strongly on an object s surface temperature This makes it possible for a thermal imaging camera to display an object s temperature However other factors also influence the radiation which limits the accuracy of this technique For example the radiation depends not only on the temperature of the object but is also a function of the emissivity of the object Also radiation originates from the surroundings and is reflected in the object and the radiation from the object and the reflected radiation will also be influenced by the absorption of the atmosphere Standards editASTM International ASTM ASTM C1060 Standard Practice for Thermographic Inspection of Insulation Installations in Envelope Cavities of Frame Buildings ASTM C1153 Standard Practice for the Location of Wet Insulation in Roofing Systems Using Infrared Imaging ATSM D4788 Standard Test Method for Detecting Delamination in Bridge Decks Using Infrared Thermography ASTM E1186 Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems ASTM E1934 Standard Guide for Examining Electrical and Mechanical Equipment with Infrared ThermographyInternational Organization for Standardization ISO ISO 6781 Thermal insulation Qualitative detection of thermal irregularities in building envelopes Infrared method ISO 18434 1 Condition monitoring and diagnostics of machines Thermography Part 1 General procedures ISO 18436 7 Condition monitoring and diagnostics of machines Requirements for qualification and assessment of personnel Part 7 ThermographyBiological counterpart editThermography by definition is by means of an instrument artifact but some living creatures have natural organs that function as counterparts to bolometers and thus possess a crude type of thermal imaging capability thermoception One of the best known examples is infrared sensing in snakes CCD and CMOS thermography edit nbsp Color contours of temperature for a smoldering ember measured with a CMOS camera Non specialized CCD and CMOS sensors have most of their spectral sensitivity in the visible light wavelength range However by utilizing the trailing area of their spectral sensitivity namely the part of the infrared spectrum called near infrared NIR and by using off the shelf CCTV camera it is possible under certain circumstances to obtain true thermal images of objects with temperatures at about 280 C 536 F and higher 27 At temperatures of 600 C and above inexpensive cameras with CCD and CMOS sensors have also been used for pyrometry in the visible spectrum They have been used for soot in flames burning coal particles heated materials SiC filaments and smoldering embers 28 This pyrometry has been performed using external filters or only the sensor s Bayer filters It has been performed using color ratios grayscales and or a hybrid of both See also editASTM Subcommittee E20 02 on Radiation Thermometry Chemical imaging The simultaneous measurement of spectra and pictures Fluorescent microthermography Infrared and thermal testing Infrared camera Imaging device using infrared radiation Infrared detector detector that reacts to infrared IR radiationPages displaying wikidata descriptions as a fallback Infrared thermometer Thermometer which infers temperature by measuring infrared energy emission Night vision Ability to see in low light conditions Non contact thermography thermography used for medical diagnosisPages displaying wikidata descriptions as a fallback Sakuma Hattori equation Formula for the thermal radiation emitted by a perfect black body Thermal imaging camera Thermal imaging camera in firefighting Thermographic inspectionReferences edit Breast Cancer Screening Thermogram No Substitute for Mammogram fda gov US Food and Drug Administration 27 October 2017 Archived from the original on 23 June 2018 Retrieved 23 June 2018 FLIR infrared cameras help detect the spreading of swine flu and other viral diseases applegate co uk 29 April 2009 Archived from the original on 29 February 2012 Retrieved 18 June 2013 a b FLIR x8500sc Thermal imaging camera specifications Retrieved on 2019 07 10 Infrared Technology thermalscope com Archived from the original on 8 November 2014 Retrieved 31 October 2014 Hapke B 19 January 2012 Theory of Reflectance and Emittance Spectroscopy Cambridge University Press p 416 ISBN 978 0 521 88349 8 Maldague XP Jones TS Kaplan H Marinetti S Prystay M 2001 Fundamentals of infrared and thermal testing In Maldague K Moore PO eds Nondestructive Handbook Infrared and Thermal Testing z Vol 3 3rd ed Columbus Ohio ASNT Press Graciani G Amblard F December 2019 Super resolution provided by the arbitrarily strong superlinearity of the blackbody radiation Nature Communications 10 1 5761 Bibcode 2019NatCo 10 5761G doi 10 1038 s41467 019 13780 4 PMC 6917796 PMID 31848354 a b c Costello JT McInerney CD Bleakley CM Selfe J Donnelly AE 2012 02 01 The use of thermal imaging in assessing skin temperature following cryotherapy a review PDF Journal of Thermal Biology 37 2 103 110 doi 10 1016 j jtherbio 2011 11 008 a b c Bach AJ Stewart IB Minett GM Costello JT September 2015 Does the technique employed for skin temperature assessment alter outcomes A systematic review PDF Physiological Measurement 36 9 R27 51 Bibcode 2015PhyM 36R 27B doi 10 1088 0967 3334 36 9 r27 PMID 26261099 S2CID 23259170 a b c Bach AJ Stewart IB Disher AE Costello JT 2015 02 06 A comparison between conductive and infrared devices for measuring mean skin temperature at rest during exercise in the heat and recovery PLOS ONE 10 2 e0117907 Bibcode 2015PLoSO 1017907B doi 10 1371 journal pone 0117907 PMC 4319934 PMID 25659140 Using Thermography to Find a Class of Latent Construction Defects Globalspec com Retrieved on 2013 06 18 F Colbert Looking Under the Hood Converting Proprietary Image File Formats Created within IR Cameras for Improved Archival Use Professional Thermographers Association Infrared Temperature Theory and Application Omega com Retrieved on 2013 06 18 IR scanning handbook PDF Nhatha NETA Retrieved 22 June 2019 Real Time Emissivity Measurement for Infrared Temperature Measurement Pyrometer com Retrieved on 2013 06 18 Kylili A Fokaides PA Christou P Kalogirou SA 2014 Infrared thermography IRT applications for building diagnostics A review Applied Energy 134 531 549 doi 10 1016 j apenergy 2014 08 005 Saxena A Ng EYK Lim ST October 2019 Infrared IR thermography as a potential screening modality for carotid artery stenosis Computers in Biology and Medicine 113 103419 doi 10 1016 j compbiomed 2019 103419 PMID 31493579 S2CID 202003120 Saxena Ashish Raman Vignesh Ng E Y K 2 October 2019 Study on methods to extract high contrast image in active dynamic thermography Quantitative InfraRed Thermography Journal 16 3 4 243 259 doi 10 1080 17686733 2019 1586376 hdl 10356 144497 S2CID 141334526 Saxena A Ng EYK Lim ST May 2020 Active dynamic thermography to detect the presence of stenosis in the carotid artery Computers in Biology and Medicine 120 103718 doi 10 1016 j compbiomed 2020 103718 PMID 32250851 S2CID 215408087 Saxena Ashish Ng E Y K Raman Vignesh Syarifuddin Bin Mohamed Hamli Muhammad Moderhak Mateusz Kolacz Szymon Jankau Jerzy December 2019 Infrared IR thermography based quantitative parameters to predict the risk of post operative cancerous breast resection flap necrosis Infrared Physics amp Technology 103 103063 Bibcode 2019InPhT 10303063S doi 10 1016 j infrared 2019 103063 S2CID 209285015 Soroko M Morel MC 2016 Equine thermography in practice Wallingford Boston CABI ISBN 9781780647876 LCCN 2016935227 Morgan Hughes Paul Hopwood Matilda Dolan Ben Dolan 4 October 2022 Applications of thermal imaging for bird surveys examples from the field Ringing and Migration 1 4 doi 10 1080 03078698 2022 2123026 ISSN 0307 8698 Wikidata Q114456608 Gaszczak A Breckon TP Han J 2011 Roning J Casasent DP Hall EL eds Real time People and Vehicle Detection from UAV Imagery Proc SPIE Conference Intelligent Robots and Computer Vision XXVIII Algorithms and Techniques Intelligent Robots and Computer Vision XXVIII Algorithms and Techniques 7878 78780B Bibcode 2011SPIE 7878E 0BG CiteSeerX 10 1 1 188 4657 doi 10 1117 12 876663 hdl 1826 7589 S2CID 18710932 Pinggera P Breckon TF Bischof H 2012 On Cross Spectral Stereo Matching using Dense Gradient Features Proceedings of the British Machine Vision Conference 2012 BMVA pp 526 1 526 12 doi 10 5244 C 26 103 ISBN 978 1 901725 46 9 a href Template Cite book html title Template Cite book cite book a journal ignored help dead link Thermographic images in active volcanoes surveillance system TIIMNet project Vesuvius and Solfatara INGV Naples Italy Archived 2012 07 10 at archive today Ipf ov ingv it Retrieved on 2013 06 18 Infrared Building Inspections Resources for Electrical Mechanical Residential and Commercial Infrared Thermal Inspections Archived 2018 08 06 at the Wayback Machine Infrared buildinginspections com 2008 09 04 Retrieved on 2013 06 18 Porev VA Porev GV 2004 Experimental determination of the temperature range of a television pyrometer Journal of Optical Technology 71 1 70 71 Bibcode 2004JOptT 71 62P doi 10 1364 JOT 71 000062 Kim Dennis K Sunderland Peter B 2019 Fire Ember Pyrometry Using a Color Camera 2019 Fire Safety Journal 106 88 93 doi 10 1016 j firesaf 2019 04 006 S2CID 145942969 https www kkbuildtech in thermal scanning for leakage best thermal scanning service provider in indiaExternal links edit nbsp Wikimedia Commons has media related to Thermography Infrared Tube infrared imaging science demonstrations Compix Some uses of thermographic images in electronics Thermographic Images Infrared pictures Uncooled thermal imaging works round the clock by Lawrence Mayes Archaeological aerial thermography IR Thermometry amp Thermography Applications Repository IR Thermometry amp Thermography Applications Repository Retrieved from https en wikipedia org w index php title Thermography amp oldid 1187753638, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.