fbpx
Wikipedia

Fluorescent-lamp formats

Since their introduction as a commercial product in 1939, many different types of fluorescent lamp have been introduced. Systematic nomenclature identifies mass-market lamps as to overall shape, power rating, length, color, and other electrical and illuminating characteristics.

Fluorescent lamps in various embodiments

Tube designations edit

In the United States and Canada, lamps are typically identified by a code such as FxxTyy, where F is for fluorescent, and the first number (xx) indicates either the power in watts for bi-pin lamps, length in inches for single pin and high output lamps, or for circular bulbs the diameter of the circular bulb. The T indicates that the shape of the bulb is tubular, and the last number (yy) is the diameter in eighths of an inch (sometimes in millimeters, rounded up to the nearest millimeter). Typical diameters are T12 or T38 (1+12 in or 38 mm) for magnetic or electronic ballasts, T8 or T26 (1 in or 25 mm) for smaller and often energy-saving lamps with magnetic or electronic ballasts, and T5 or T16 (58 in or 16 mm) for very small lamps, which may even operate from a battery-powered device.

Fluorescent tube diameter designation comparison
Designation Tube diameter Extra
(in) (mm) Socket Notes
T2 14 approx. 7 WP4.5×8.5d
T4 12 12.7 G5 bi-pin Slim lamps. Power ratings and lengths not standardized (and not the same) between different manufacturers
T5 T16 58 15.9
  • G5 bi-pin
  • 2GX13 quad-pin
  • G10q quad-pin
  • Original 4–13 W range from 1950s or earlier.[1]
  • Two newer ranges, high efficiency (HE) 14–35 W, and high output (HO) 24–80 W, introduced in the 1990s.[2]
  • Panasonic's range of FHL fluorescent tubes in 18W, 27W, and 36W varieties for the Japanese market.
  • Circular fluorescent tubes.
  • Thorn/General Electric 2D fluorescent lamps and other similar lamps from various manufacturers.
T6 34 19.05 Fa8 single-pin Single-pin fluorescent lamps.
T8 T26 1 25.4
  • G13 bi-pin
  • Fa8 single-pin
  • R17d recessed double contact
One of the first diameters of fluorescent lamps, with the 15W T8 and 30W T8 having been introduced in 1938.[3] The European energy saving krypton T8 lamps introduced by Thorn EMI at the 1970s.[4] The North American energy-saving argon T8 lamps weren't introduced until the 1980s.[5]
T9 T29 1+18 28.6
  • G10q quad-pin
  • G13 bi-pin
  • Circular fluorescent tubes
  • Some linear tubes
T10 1+14 31.75
  • G13 bi-pin
  • G10q quad-pin
  • High-lumen retrofit lamps for 40W T12 lamps in North America.
  • Popular tube diameter in Japan
  • Circular 32W and 40W T10 lamps (Older versions of the 32W and 40W T9 lamps)
T12 T38 1+12 38.1
  • G13 bi-pin
  • Fa8 single-pin
  • R17d recessed double contact
One of the first diameters of fluorescent lamps, with the 15W T12 and 20W T12 having been introduced in 1938. These aren't as efficient as newer lamp options.[6]
T17 2+18 54 G20 Mogul bi-pin Large size for 90W T17 (preheat) and 40W T17 (instant start)
PG17 2+18 54 R17d Recessed double contact General Electric's Power Groove tubes

For T2–T12 and T17, the number indicates the tube diameter in 18 inches, e.g. T2 → 28 in and T17 → 178 in. Whereas for T16 and T26–T38, the number indicates the approximate tube diameter in millimeters.

Reflectors edit

 
Cross section of a typical fluorescent lamp with and without a reflector

Some lamps have an internal opaque reflector. Coverage of the reflector ranges from 120° to 310° of the lamp's circumference.

Reflector lamps are used when light is only desired to be emitted in a single direction, or when an application requires the maximum amount of light. For example, these lamps can be used in tanning beds or in backlighting electronic displays. An internal reflector is more efficient than standard external reflectors. Another example is color matched aperture lights (with about 30° of opening) used in the food industry for robotic quality control inspection of cooked goods.

Aperture lamps have a clear break in the phosphor coating, typically of 30°, to concentrate light in one direction and provide higher brightness in the beam than can be achieved by uniform phosphor coatings. Aperture lamps include reflectors over the non-aperture area. Aperture lamps were commonly used in photocopiers in the 1960s and 1970s where a bank of fixed tubes was arranged to light up the image to be copied, but are rarely found nowadays. Aperture lamps can produce a concentrated beam of light suitable for edge-lit signs.

Single pin lamps edit

Single pin lamps (Also generically called "Slimline" in the United States) operate in the United States and Canada on an instant start ballast or, In 220-240V countries, with a series choke without a starter.

High output/very high output lamps edit

High-output lamps are brighter and are driven at a higher electric current, have different ends on the pins so they cannot be used in the wrong fixture. Since about the early to mid-1950s to today, General Electric developed and improved the Power Groove lamp. These lamps are recognizable by their large diameter (2+18 in or 54 mm), grooved tube shape and an R17d cap on each end.

Colors edit

Color is usually indicated by WW for warm white, EW for enhanced (neutral) white, CW for cool white, and D for the bluish daylight white. BL is used for ultraviolet lamps commonly used in bug zappers. BLB is used for blacklight-blue lamps employing a Wood's glass envelope to filter out most visible light, commonly used in nightclubs. Other non-standard designations apply for plant lights or grow lights.

Philips and Osram use numeric color codes for the colors. On tri-phosphor and multi-phosphor tubes, the first digit indicates the color rendering index (CRI) of the lamp. If the first digit on a lamp says 8, then the CRI of that lamp will be approximately 85. The last two digits indicate the color temperature of the lamp in kelvins (K). For example, if the last two digits on a lamp say 41, that lamp's color temperature will be 4100 K, which is a common tri-phosphor cool white fluorescent lamp.

Halophosphate tubes
Japanese color code Numeric color code Alphabetic color code Color Approximate CRI Color temperature (K)
N/A 29 WW Warm white ≈52 3000
WW 35 W White ≈56 3500
W 33 CW Cool White ≈62 4000-4300
N/A 25 N/A Neutral/Universal White ≈75 4000
N N/A N/A Natural Daylight ≈70 5000
D 54 D Daylight ≈75 6500
Deluxe halophosphate tubes
Japanese color code Numeric color code Alphabetic color code Color Approximate CRI Color temperature (K)
L-EDL 27 N/A Deluxe Extra Warm White ≈95 2700
N/A N/A SW GE Soft White (Lower-CRI WWX) ≈77 3000
N/A 32 WWX Deluxe Warm White ≈87 3000
N/A N/A WX Sylvania White Deluxe ≈85 3500
N/A 79 N Natural ≈90 3600
N/A 34 N/A Deluxe White ≈85 3850
W-SDL 38 CWX Deluxe Cool White/Kolor-rite ≈90 4000
N/A N/A C41 GE Cool White Utility (Enhanced CWX) ≈87 4100
N-SDL, N-EDL N/A C50/DSGN50 GE Chroma 50/Philips Colortone 50/Sylvania Design 50 ≈90-99 5000
D-SDL, D-EDL 55 DX Deluxe Daylight/Northlight/Colour Matching ≈88-98 6500
N/A N/A C75 GE Chroma 75/Philips Colortone 75 ≈92 7500
700-series tubes (halophosphate and tri-phosphor blend)
Numeric color code Alphanumeric color code Color Approximate CRI Color temperature (K)
730 SP30/D30/TL730 Warm White ≈75 3000
735 SP35/D35/TL735 Neutral White ≈75 3500
741 SP41/D41/TL741 Cool White ≈75 4100
750 SP50/TL750 Natural Daylight ≈75 5000
765 SP65/TL765 Cool Daylight ≈75 6500
800-series tri-phosphor tubes
Japanese Color Code Numeric color code Color Approximate CRI Color temperature (K)
ELX 825 Sunset White ≈85 2500
ELR, ELC 827, 828 Extra Warm white ≈85 2700, 2800
EX-L, EL, ELK 830 Warm White ≈85 3000
ELW 832 Warm White ≈85 3200
EX-WW, EWW 835 Neutral White ≈85 3500
EW38 838 Neutral White ≈85 3800
EX-W, EW 840, 841, 842 Cool White ≈85 4000, 4100, 4200
EX-N, EN 850 Natural Daylight ≈85 5000
ENW, ENM, ENC 852, 853 Natural Daylight ≈85 5200, 5300
ENK 855 Natural Daylight ≈85 5500
ENX 858 Natural Daylight ≈85 5800
EDW 862 Cool Daylight ≈85 6200
EX-D, ED 865, 867 Cool Daylight ≈85 6500, 6700
ECW, EDK, EDC 872, 874 Cool Daylight ≈85 7200, 7400
EDF, EDX 880 Skywhite ≈85 8000
Multi-phosphor tubes
Numeric color code Color Approximate CRI Color temperature (K)
927 Warm white ≈95 2700
941 Cool white ≈95 4100
950 Natural Daylight ≈98 5000
965 Cool daylight ≈95 6500
Special purpose tubes
Numeric code Alphabetic Code Fluorescent

lamp type

Notes
05 N/A Germicidal lamps No phosphors used in these lamps at all, and the enveplope is made of fused quartz instead of glass.

In the American lamp code, the F as in FxxTyy is replaced by a G as in GxxTyy, indicating that it's a germicidal lamp.

08 BLB Black-Light Blue lamps These lamps are similar to the regular black light lamps, except they use wood's glass as a filter to reduce the amount of visible light emitted. These lamps are used for fluorescence effects where less visible light is ideal.
09 N/A Sun-tanning lamps These lamps produce wide or narrow band UV-B radiation
10 BL Black-Light lamps Black light lamps give off long-wave UV-A radiation of around 350-400 nm. They are often used to attract insects to traps. Unlike black light blue lamps, these lamps do not use wood's glass. They use regular soda-lime glass and emit more visible light than BLB lamps.

Common tube ratings edit

This section lists the more common tube ratings for general lighting. Many more tube ratings exist, often country-specific. The Nominal Length may not exactly match any measured dimension of the tube. For some tube sizes, the nominal length (in feet) is the required spacing between centers of the lighting fixtures to create a continuous run, so the tubes are a little shorter than the nominal length.

Tube diameter in 18 in (3.175 mm) Nominal length Nominal power (W) Lamp Code
T5 6 in (152 mm) 4 F4T5
T5 9 in (229 mm) 6 F6T5
T5 12 in (305 mm) 8 F8T5
T5 21 in (533 mm) 13 F13T5
T5/HE 22 in (560 mm) 14 F14T5
T5/HE 34 in (860 mm) 21 F21T5
T5/HE 46 in (1,200 mm) 28 F28T5
T5/HE 58 in (1,500 mm) 35 F35T5
T5/HO 22 in (560 mm) 24 F24T5/HO
T5/HO 34 in (860 mm) 39 F39T5/HO
T5/HO 46 in (1,200 mm) 54 F54T5/HO
T5/HO 58 in (1,500 mm) 80 F80T5/HO
T8 15 in (381 mm) 14 F14T8
T8 18 in (460 mm) 15 F15T8
T8 2 ft (610 mm) 17

18

F17T8

F18T8

T8 3 ft (914 mm) 25

30

F25T8

F30T8

T8 4 ft (1,219 mm) 32

36

F32T8

F36T8

T8 5 ft (1,524 mm) 40

58

F40T8

F58T8

T8 6 ft (1,829 mm) 70 F70T8
T8 single pin 6 ft (1,829 mm) 38 F72T8
T8 single pin 8 ft (2,438 mm) 59 F96T8
T8/HO 4 ft (1,219 mm) 44 F48T8/HO
T8/HO 5 ft (1,524 mm) 55 F60T8/HO
T8/HO 6 ft (1,829 mm) 65 F72T8/HO
T8/HO 8 ft (2,438 mm) 86 F96T8/HO
T12 15 in (381 mm) 14 F14T12
T12 18 in (457 mm) 15 F15T12
T12 2 ft (610 mm) 20 F20T12
T12 4 ft (1,219 mm) 40 F40T12
T12 5 ft (1,524 mm) 65

80

F65T12

F80T12

T12 6 ft (1,829 mm) 75

85

F75T12

F85T12

T12 8 ft (2,438 mm) 125 F125T12
T12 single pin 4 ft (1,219 mm) 39 F48T12
T12 single pin 6 ft (1,829 mm) 55 F72T12
T12 single pin 8 ft (2,438 mm) 75 F96T12
T12/HO 4 ft (1,219 mm) 60 F48T12/HO
T12/HO 5 ft (1,524 mm) 75 F60T12/HO
T12/HO 6 ft (1,829 mm) 85 F72T12/HO
T12/HO 8 ft (2,438 mm) 110 F96T12/HO
T12/VHO 4 ft (1,219 mm) 115 F48T12/VHO
T12/VHO 6 ft (1,829 mm) 160 F72T12/VHO
T12/VHO 8 ft (2,438 mm) 215 F96T12/VHO

European energy-saving tubes edit

In the 1970s, Thorn Lighting introduced an energy-saving 8 ft retrofit tube in Europe. Designed to run on the existing 125 W (240 V) series ballast but with a different gas fill and operating voltage, the tube operated at only 100 W. Increased efficiency meant that the tube produced only 9% lumen reduction for a 20% power reduction.[7] This first energy-saving tube design remains a T12 tube even today. However, follow-on retrofit replacements for all the other original T12 tubes were T8, which helped with creating the required electrical characteristics and saving on the then new (and more expensive) polyphosphor/triphosphor coatings, and these were even more efficient. Note that because these tubes were all designed as retrofit tubes to be fitted in T12 fittings running on series ballasts on 220–240 V supplies, they could not be used in 120 V mains countries with inherently different control gear designs.

Type Diameter (in, mm) Nominal length (ft, m) Nominal power (W) Notes
T8 1.0, 25 2, 0.6 18 Retrofit replacement for 2 ft T12 20 W
T8 1.0, 25 4, 1.2 36 Retrofit replacement for 4 ft T12 40 W
T8 1.0, 25 5, 1.5 58 Retrofit replacement for 5 ft T12 65 W
T8 1.0, 25 6, 1.8 70 Retrofit replacement for 6 ft T12 75 W
T12 1.5, 38 8, 2.4 100 Retrofit replacement for 8 ft T12 125 W

Around 1980 (in the UK, at least), some new fluorescent fittings were designed to take only the newer, retrofit tubes (the lamp holders are designed not to take T12 tubes, except for 8 ft length). The earlier T12 halophosphate tubes still remained available as spares until 2012. They fit in older fittings and some modern fittings that employ twist lock lamp holders, even though the modern fittings were not electrically designed for them.

US energy-saving tubes edit

In the 1970s, 34-watt energy-saving F40T12 4-foot fluorescent lamps were intoroduced in the US. In the 1980s, T8 32-watt versions were introduced,[8] but unlike the T8 tubes introduced in Europe, the T8s are not retrofits and require new matching ballasts to drive them, while some T12s can use the older ballasts. Running a T8 tube with a ballast for T12 will reduce lamp life and can increase energy consumption.[9] Conversely, a T12 tube on a T8 ballast will usually draw too much power and so may burn out the ballast, unless it is within the range that the particular model of electronic ballast can compensate for. The tube type should always match the markings on the light fixture.

Type Diameter (in, mm) Nominal length (ft) Nominal power (W) Lamp Code Notes
T5 0.625, 16 4 49 F49T5 Retrofit replacement for 4 ft T5HO 54 W
T8 1.0, 25 4 25 F32T8/25w Retrofit replacement for 4 ft T8 32 W
T8 1.0, 25 4 28 F28T8 Retrofit replacement for 4 ft T8 32 W
T8 1.0, 25 4 30 F32T8/ES Retrofit replacement for 4 ft T8 32 W
T8 1.0, 25 2 17 F17T8 Retrofit replacement for 2 ft T12 20 W
T8 1.0, 25 3 25 F25T8 Retrofit replacement for 3 ft T12 30 W
T8 1.0, 25 4 32 F32T8 Retrofit replacement for 4 ft T12 40 W
T8 1.0, 25 5 40 F40T8
T8 1.0, 25 8 59 F96T8 Retrofit replacement for 8 ft T12 75 W single pin
T12 1.5, 38 4 25 F40UTSL

F40SHOP

Replacement for 4 ft T12 40 W on residential grade rapid

start magnetic ballast. These are F40CW lamps made with cheaper cathodes that got around the 1995 ban on regular F40CW lamps. These lamps are rated to last for 12000 hours on a residential grade ballast and only 6000 hours on a commercial grade one.

T12 1.5, 38 4 34 F34T12 Retrofit replacement for 4 ft T12 40 W
T12 1.5, 38 8 60 F96T12/ES Retrofit replacement for 8 ft T12 75 W single pin
T12 1.5, 38 8 95 F96T12/HO/ES Retrofit replacement for 8 ft T12 110 W high output

T5 tubes edit

In the 1990s, longer T5 tubes were designed in Europe (making it to North America in the 2000s), in addition to the shorter ones (mentioned above) already in use worldwide. Like the European modular furniture, display cabinets, ceiling tile grids, etc. they were designed for, these are based on multiples of the 300 mm (11.8 in) "metric foot" instead of the 12 in (305 mm) imperial foot, but are all 37 mm (1.5 in) shorter to allow space for the lampholder connections within the 300 mm modular units, and for much easier insertion into and removal from troffer lights within the grid.

Tube diameter is 58 in (15.875 mm) Length Nominal power (W) Notes
High-efficiency High output
T5 563 mm (22.2 in) 14 24 Fits within a 0.6 m modular unit
T5 863 mm (34.0 in) 21 39 Fits within a 0.9 m modular unit
T5 1,163 mm (45.8 in) 28 54 Fits within a 1.2 m modular unit
T5 1,463 mm (57.6 in) 35 80 Fits within a 1.5 m modular unit

The T5 diameter is nearly 40% smaller than T8 lamps and almost 60% smaller than T12 lamps. T5 lamps have a G5 base (bi-pin with 5 mm spacing), even for high-output (HO and VHO) tubes.[10]

See also edit

References edit

  1. ^ Funke and Oranje, "Gas Discharge Lamps"; N.V Philips' Gloeilampenfabrieken (1951)
  2. ^ "The T5 Fluorescent Lamp: Coming on Strong". 1 September 2003. Retrieved 20 February 2020.
  3. ^ . Archived from the original on 24 March 2007. Retrieved 28 September 2008.
  4. ^ "The Fluorescent Lamp – Gas Fillings". lamptech.co.uk. Retrieved 30 August 2023.
  5. ^ . Archived from the original on 16 September 2008. Retrieved 28 September 2008.
  6. ^ . Archived from the original on 16 September 2008. Retrieved 28 September 2008.
  7. ^ Thorn Lighting Technical Handbook
  8. ^ "4-Foot T-8 Fluorescent Lamp Upgrading". Retrieved 2 November 2022.
  9. ^ . 1 November 1995. Archived from the original on 22 May 2011.
  10. ^ Lighting Research Center, "T5 Fluorescent Systems", [1], accessed 11-30-2009.

fluorescent, lamp, formats, other, types, lightbulb, mounts, sockets, lightbulb, socket, since, their, introduction, commercial, product, 1939, many, different, types, fluorescent, lamp, have, been, introduced, systematic, nomenclature, identifies, mass, marke. For other types of lightbulb mounts and sockets see Lightbulb socket Since their introduction as a commercial product in 1939 many different types of fluorescent lamp have been introduced Systematic nomenclature identifies mass market lamps as to overall shape power rating length color and other electrical and illuminating characteristics Fluorescent lamps in various embodiments Contents 1 Tube designations 1 1 Reflectors 1 2 Single pin lamps 1 3 High output very high output lamps 1 4 Colors 2 Common tube ratings 2 1 European energy saving tubes 2 2 US energy saving tubes 3 T5 tubes 4 See also 5 ReferencesTube designations editIn the United States and Canada lamps are typically identified by a code such as FxxTyy where F is for fluorescent and the first number xx indicates either the power in watts for bi pin lamps length in inches for single pin and high output lamps or for circular bulbs the diameter of the circular bulb The T indicates that the shape of the bulb is tubular and the last number yy is the diameter in eighths of an inch sometimes in millimeters rounded up to the nearest millimeter Typical diameters are T12 or T38 1 1 2 in or 38 mm for magnetic or electronic ballasts T8 or T26 1 in or 25 mm for smaller and often energy saving lamps with magnetic or electronic ballasts and T5 or T16 5 8 in or 16 mm for very small lamps which may even operate from a battery powered device Fluorescent tube diameter designation comparison Designation Tube diameter Extra in mm Socket NotesT2 1 4 approx 7 WP4 5 8 5d Osram s Fluorescent Miniature FM tubes Sylvania Luxline Slim T2 LinearT4 1 2 12 7 G5 bi pin Slim lamps Power ratings and lengths not standardized and not the same between different manufacturersT5 T16 5 8 15 9 G5 bi pin 2GX13 quad pin G10q quad pin Original 4 13 W range from 1950s or earlier 1 Two newer ranges high efficiency HE 14 35 W and high output HO 24 80 W introduced in the 1990s 2 Panasonic s range of FHL fluorescent tubes in 18W 27W and 36W varieties for the Japanese market Circular fluorescent tubes Thorn General Electric 2D fluorescent lamps and other similar lamps from various manufacturers T6 3 4 19 05 Fa8 single pin Single pin fluorescent lamps T8 T26 1 25 4 G13 bi pin Fa8 single pin R17d recessed double contact One of the first diameters of fluorescent lamps with the 15W T8 and 30W T8 having been introduced in 1938 3 The European energy saving krypton T8 lamps introduced by Thorn EMI at the 1970s 4 The North American energy saving argon T8 lamps weren t introduced until the 1980s 5 T9 T29 1 1 8 28 6 G10q quad pin G13 bi pin Circular fluorescent tubes Some linear tubesT10 1 1 4 31 75 G13 bi pin G10q quad pin High lumen retrofit lamps for 40W T12 lamps in North America Popular tube diameter in Japan Circular 32W and 40W T10 lamps Older versions of the 32W and 40W T9 lamps T12 T38 1 1 2 38 1 G13 bi pin Fa8 single pin R17d recessed double contact One of the first diameters of fluorescent lamps with the 15W T12 and 20W T12 having been introduced in 1938 These aren t as efficient as newer lamp options 6 T17 2 1 8 54 G20 Mogul bi pin Large size for 90W T17 preheat and 40W T17 instant start PG17 2 1 8 54 R17d Recessed double contact General Electric s Power Groove tubesFor T2 T12 and T17 the number indicates the tube diameter in 1 8 inches e g T2 2 8 in and T17 17 8 in Whereas for T16 and T26 T38 the number indicates the approximate tube diameter in millimeters Reflectors edit nbsp Cross section of a typical fluorescent lamp with and without a reflectorSome lamps have an internal opaque reflector Coverage of the reflector ranges from 120 to 310 of the lamp s circumference Reflector lamps are used when light is only desired to be emitted in a single direction or when an application requires the maximum amount of light For example these lamps can be used in tanning beds or in backlighting electronic displays An internal reflector is more efficient than standard external reflectors Another example is color matched aperture lights with about 30 of opening used in the food industry for robotic quality control inspection of cooked goods Aperture lamps have a clear break in the phosphor coating typically of 30 to concentrate light in one direction and provide higher brightness in the beam than can be achieved by uniform phosphor coatings Aperture lamps include reflectors over the non aperture area Aperture lamps were commonly used in photocopiers in the 1960s and 1970s where a bank of fixed tubes was arranged to light up the image to be copied but are rarely found nowadays Aperture lamps can produce a concentrated beam of light suitable for edge lit signs Single pin lamps edit Single pin lamps Also generically called Slimline in the United States operate in the United States and Canada on an instant start ballast or In 220 240V countries with a series choke without a starter High output very high output lamps edit High output lamps are brighter and are driven at a higher electric current have different ends on the pins so they cannot be used in the wrong fixture Since about the early to mid 1950s to today General Electric developed and improved the Power Groove lamp These lamps are recognizable by their large diameter 2 1 8 in or 54 mm grooved tube shape and an R17d cap on each end Colors edit Color is usually indicated by WW for warm white EW for enhanced neutral white CW for cool white and D for the bluish daylight white BL is used for ultraviolet lamps commonly used in bug zappers BLB is used for blacklight blue lamps employing a Wood s glass envelope to filter out most visible light commonly used in nightclubs Other non standard designations apply for plant lights or grow lights Philips and Osram use numeric color codes for the colors On tri phosphor and multi phosphor tubes the first digit indicates the color rendering index CRI of the lamp If the first digit on a lamp says 8 then the CRI of that lamp will be approximately 85 The last two digits indicate the color temperature of the lamp in kelvins K For example if the last two digits on a lamp say 41 that lamp s color temperature will be 4100 K which is a common tri phosphor cool white fluorescent lamp Halophosphate tubesJapanese color code Numeric color code Alphabetic color code Color Approximate CRI Color temperature K N A 29 WW Warm white 52 3000WW 35 W White 56 3500W 33 CW Cool White 62 4000 4300N A 25 N A Neutral Universal White 75 4000N N A N A Natural Daylight 70 5000D 54 D Daylight 75 6500Deluxe halophosphate tubesJapanese color code Numeric color code Alphabetic color code Color Approximate CRI Color temperature K L EDL 27 N A Deluxe Extra Warm White 95 2700N A N A SW GE Soft White Lower CRI WWX 77 3000N A 32 WWX Deluxe Warm White 87 3000N A N A WX Sylvania White Deluxe 85 3500N A 79 N Natural 90 3600N A 34 N A Deluxe White 85 3850W SDL 38 CWX Deluxe Cool White Kolor rite 90 4000N A N A C41 GE Cool White Utility Enhanced CWX 87 4100N SDL N EDL N A C50 DSGN50 GE Chroma 50 Philips Colortone 50 Sylvania Design 50 90 99 5000D SDL D EDL 55 DX Deluxe Daylight Northlight Colour Matching 88 98 6500N A N A C75 GE Chroma 75 Philips Colortone 75 92 7500700 series tubes halophosphate and tri phosphor blend Numeric color code Alphanumeric color code Color Approximate CRI Color temperature K 730 SP30 D30 TL730 Warm White 75 3000735 SP35 D35 TL735 Neutral White 75 3500741 SP41 D41 TL741 Cool White 75 4100750 SP50 TL750 Natural Daylight 75 5000765 SP65 TL765 Cool Daylight 75 6500800 series tri phosphor tubesJapanese Color Code Numeric color code Color Approximate CRI Color temperature K ELX 825 Sunset White 85 2500ELR ELC 827 828 Extra Warm white 85 2700 2800EX L EL ELK 830 Warm White 85 3000ELW 832 Warm White 85 3200EX WW EWW 835 Neutral White 85 3500EW38 838 Neutral White 85 3800EX W EW 840 841 842 Cool White 85 4000 4100 4200EX N EN 850 Natural Daylight 85 5000ENW ENM ENC 852 853 Natural Daylight 85 5200 5300ENK 855 Natural Daylight 85 5500ENX 858 Natural Daylight 85 5800EDW 862 Cool Daylight 85 6200EX D ED 865 867 Cool Daylight 85 6500 6700ECW EDK EDC 872 874 Cool Daylight 85 7200 7400EDF EDX 880 Skywhite 85 8000Multi phosphor tubesNumeric color code Color Approximate CRI Color temperature K 927 Warm white 95 2700941 Cool white 95 4100950 Natural Daylight 98 5000965 Cool daylight 95 6500Special purpose tubesNumeric code Alphabetic Code Fluorescent lamp type Notes05 N A Germicidal lamps No phosphors used in these lamps at all and the enveplope is made of fused quartz instead of glass In the American lamp code the F as in FxxTyy is replaced by a G as in GxxTyy indicating that it s a germicidal lamp 08 BLB Black Light Blue lamps These lamps are similar to the regular black light lamps except they use wood s glass as a filter to reduce the amount of visible light emitted These lamps are used for fluorescence effects where less visible light is ideal 09 N A Sun tanning lamps These lamps produce wide or narrow band UV B radiation10 BL Black Light lamps Black light lamps give off long wave UV A radiation of around 350 400 nm They are often used to attract insects to traps Unlike black light blue lamps these lamps do not use wood s glass They use regular soda lime glass and emit more visible light than BLB lamps Common tube ratings editThis section lists the more common tube ratings for general lighting Many more tube ratings exist often country specific The Nominal Length may not exactly match any measured dimension of the tube For some tube sizes the nominal length in feet is the required spacing between centers of the lighting fixtures to create a continuous run so the tubes are a little shorter than the nominal length Tube diameter in 1 8 in 3 175 mm Nominal length Nominal power W Lamp CodeT5 6 in 152 mm 4 F4T5T5 9 in 229 mm 6 F6T5T5 12 in 305 mm 8 F8T5T5 21 in 533 mm 13 F13T5T5 HE 22 in 560 mm 14 F14T5T5 HE 34 in 860 mm 21 F21T5T5 HE 46 in 1 200 mm 28 F28T5T5 HE 58 in 1 500 mm 35 F35T5T5 HO 22 in 560 mm 24 F24T5 HOT5 HO 34 in 860 mm 39 F39T5 HOT5 HO 46 in 1 200 mm 54 F54T5 HOT5 HO 58 in 1 500 mm 80 F80T5 HOT8 15 in 381 mm 14 F14T8T8 18 in 460 mm 15 F15T8T8 2 ft 610 mm 17 18 F17T8 F18T8T8 3 ft 914 mm 25 30 F25T8 F30T8T8 4 ft 1 219 mm 32 36 F32T8 F36T8T8 5 ft 1 524 mm 40 58 F40T8 F58T8T8 6 ft 1 829 mm 70 F70T8T8 single pin 6 ft 1 829 mm 38 F72T8T8 single pin 8 ft 2 438 mm 59 F96T8T8 HO 4 ft 1 219 mm 44 F48T8 HOT8 HO 5 ft 1 524 mm 55 F60T8 HOT8 HO 6 ft 1 829 mm 65 F72T8 HOT8 HO 8 ft 2 438 mm 86 F96T8 HOT12 15 in 381 mm 14 F14T12T12 18 in 457 mm 15 F15T12T12 2 ft 610 mm 20 F20T12T12 4 ft 1 219 mm 40 F40T12T12 5 ft 1 524 mm 65 80 F65T12 F80T12T12 6 ft 1 829 mm 75 85 F75T12 F85T12T12 8 ft 2 438 mm 125 F125T12T12 single pin 4 ft 1 219 mm 39 F48T12T12 single pin 6 ft 1 829 mm 55 F72T12T12 single pin 8 ft 2 438 mm 75 F96T12T12 HO 4 ft 1 219 mm 60 F48T12 HOT12 HO 5 ft 1 524 mm 75 F60T12 HOT12 HO 6 ft 1 829 mm 85 F72T12 HOT12 HO 8 ft 2 438 mm 110 F96T12 HOT12 VHO 4 ft 1 219 mm 115 F48T12 VHOT12 VHO 6 ft 1 829 mm 160 F72T12 VHOT12 VHO 8 ft 2 438 mm 215 F96T12 VHOEuropean energy saving tubes edit In the 1970s Thorn Lighting introduced an energy saving 8 ft retrofit tube in Europe Designed to run on the existing 125 W 240 V series ballast but with a different gas fill and operating voltage the tube operated at only 100 W Increased efficiency meant that the tube produced only 9 lumen reduction for a 20 power reduction 7 This first energy saving tube design remains a T12 tube even today However follow on retrofit replacements for all the other original T12 tubes were T8 which helped with creating the required electrical characteristics and saving on the then new and more expensive polyphosphor triphosphor coatings and these were even more efficient Note that because these tubes were all designed as retrofit tubes to be fitted in T12 fittings running on series ballasts on 220 240 V supplies they could not be used in 120 V mains countries with inherently different control gear designs Type Diameter in mm Nominal length ft m Nominal power W NotesT8 1 0 25 2 0 6 18 Retrofit replacement for 2 ft T12 20 WT8 1 0 25 4 1 2 36 Retrofit replacement for 4 ft T12 40 WT8 1 0 25 5 1 5 58 Retrofit replacement for 5 ft T12 65 WT8 1 0 25 6 1 8 70 Retrofit replacement for 6 ft T12 75 WT12 1 5 38 8 2 4 100 Retrofit replacement for 8 ft T12 125 WAround 1980 in the UK at least some new fluorescent fittings were designed to take only the newer retrofit tubes the lamp holders are designed not to take T12 tubes except for 8 ft length The earlier T12 halophosphate tubes still remained available as spares until 2012 They fit in older fittings and some modern fittings that employ twist lock lamp holders even though the modern fittings were not electrically designed for them US energy saving tubes edit In the 1970s 34 watt energy saving F40T12 4 foot fluorescent lamps were intoroduced in the US In the 1980s T8 32 watt versions were introduced 8 but unlike the T8 tubes introduced in Europe the T8s are not retrofits and require new matching ballasts to drive them while some T12s can use the older ballasts Running a T8 tube with a ballast for T12 will reduce lamp life and can increase energy consumption 9 Conversely a T12 tube on a T8 ballast will usually draw too much power and so may burn out the ballast unless it is within the range that the particular model of electronic ballast can compensate for The tube type should always match the markings on the light fixture Type Diameter in mm Nominal length ft Nominal power W Lamp Code NotesT5 0 625 16 4 49 F49T5 Retrofit replacement for 4 ft T5HO 54 WT8 1 0 25 4 25 F32T8 25w Retrofit replacement for 4 ft T8 32 WT8 1 0 25 4 28 F28T8 Retrofit replacement for 4 ft T8 32 WT8 1 0 25 4 30 F32T8 ES Retrofit replacement for 4 ft T8 32 WT8 1 0 25 2 17 F17T8 Retrofit replacement for 2 ft T12 20 WT8 1 0 25 3 25 F25T8 Retrofit replacement for 3 ft T12 30 WT8 1 0 25 4 32 F32T8 Retrofit replacement for 4 ft T12 40 WT8 1 0 25 5 40 F40T8T8 1 0 25 8 59 F96T8 Retrofit replacement for 8 ft T12 75 W single pinT12 1 5 38 4 25 F40UTSL F40SHOP Replacement for 4 ft T12 40 W on residential grade rapid start magnetic ballast These are F40CW lamps made with cheaper cathodes that got around the 1995 ban on regular F40CW lamps These lamps are rated to last for 12000 hours on a residential grade ballast and only 6000 hours on a commercial grade one T12 1 5 38 4 34 F34T12 Retrofit replacement for 4 ft T12 40 WT12 1 5 38 8 60 F96T12 ES Retrofit replacement for 8 ft T12 75 W single pinT12 1 5 38 8 95 F96T12 HO ES Retrofit replacement for 8 ft T12 110 W high outputT5 tubes editIn the 1990s longer T5 tubes were designed in Europe making it to North America in the 2000s in addition to the shorter ones mentioned above already in use worldwide Like the European modular furniture display cabinets ceiling tile grids etc they were designed for these are based on multiples of the 300 mm 11 8 in metric foot instead of the 12 in 305 mm imperial foot but are all 37 mm 1 5 in shorter to allow space for the lampholder connections within the 300 mm modular units and for much easier insertion into and removal from troffer lights within the grid Tube diameter is 5 8 in 15 875 mm Length Nominal power W NotesHigh efficiency High outputT5 563 mm 22 2 in 14 24 Fits within a 0 6 m modular unitT5 863 mm 34 0 in 21 39 Fits within a 0 9 m modular unitT5 1 163 mm 45 8 in 28 54 Fits within a 1 2 m modular unitT5 1 463 mm 57 6 in 35 80 Fits within a 1 5 m modular unitThe T5 diameter is nearly 40 smaller than T8 lamps and almost 60 smaller than T12 lamps T5 lamps have a G5 base bi pin with 5 mm spacing even for high output HO and VHO tubes 10 See also editCompact fluorescent lamp List of light sources Fluorescent lamp recycling T5 retrofit conversionReferences edit Funke and Oranje Gas Discharge Lamps N V Philips Gloeilampenfabrieken 1951 The T5 Fluorescent Lamp Coming on Strong 1 September 2003 Retrieved 20 February 2020 Covington E J The Story Behind This Account of Fluorescent Lamp Development Archived from the original on 24 March 2007 Retrieved 28 September 2008 The Fluorescent Lamp Gas Fillings lamptech co uk Retrieved 30 August 2023 Lawrence Berkeley National Laboratory T 8 lamp retrofits Archived from the original on 16 September 2008 Retrieved 28 September 2008 Lawrence Berkeley National Laboratory History and problems of T12 fluorescent lamps Archived from the original on 16 September 2008 Retrieved 28 September 2008 Thorn Lighting Technical Handbook 4 Foot T 8 Fluorescent Lamp Upgrading Retrieved 2 November 2022 Energy Codes 1 November 1995 Archived from the original on 22 May 2011 Lighting Research Center T5 Fluorescent Systems 1 accessed 11 30 2009 Retrieved from https en wikipedia org w index php title Fluorescent lamp formats amp oldid 1189691860, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.