fbpx
Wikipedia

Synchronous motor

A synchronous electric motor is an AC electric motor in which, at steady state,[1] the rotation of the shaft is synchronized with the frequency of the supply current; the rotation period is exactly equal to an integral number of AC cycles. Synchronous motors contain multiphase AC electromagnets on the stator of the motor that create a magnetic field which rotates in time with the oscillations of the line current. The rotor with permanent magnets or electromagnets turns in step with the stator field at the same rate and as a result, provides the second synchronized rotating magnet field of any AC motor. A synchronous motor is termed doubly fed if it is supplied with independently excited multiphase AC electromagnets on both the rotor and stator.[2]

Miniature synchronous motor used in analog clocks. The rotor is made of permanent magnet.
Small synchronous motor with integral stepdown gear from a microwave oven

The synchronous motor and the induction motor are the most widely used types of AC motors. The difference between the two types is that the synchronous motor rotates at a rate locked to the line frequency since it does not rely on current induction to produce the rotor's magnetic field. By contrast, the induction motor requires slip: the rotor must rotate slightly slower than the AC alternations in order to induce current in the rotor winding. Small synchronous motors are used in timing applications such as in synchronous clocks, timers in appliances, tape recorders and precision servomechanisms in which the motor must operate at a precise speed; speed accuracy is that of the power line frequency, which is carefully controlled in large interconnected grid systems.[citation needed]

Synchronous motors are available in self-excited sub-fractional horsepower sizes[3] to high power industrial sizes.[1] In the fractional horsepower range, most synchronous motors are used where precise constant speed is required. These machines are commonly used in analog electric clocks, timers and other devices where correct time is required. In higher power industrial sizes, the synchronous motor provides two important functions. First, it is a highly efficient means of converting AC energy to work. Second, it can operate at leading or unity power factor and thereby provide power-factor correction.

Type

Synchronous motors fall under the more general category of synchronous machines which also includes the synchronous generator. Generator action will be observed if the field poles are "driven ahead of the resultant air-gap flux by the forward motion of the prime mover". Motor action will be observed if the field poles are "dragged behind the resultant air-gap flux by the retarding torque of a shaft load".[1]

There are two major types of synchronous motors depending on how the rotor is magnetized: non-excited and direct-current excited.[4]

Non-excited

 
Single-phase 60 Hz 1800 RPM synchronous motor for Teletype machine, non-excited rotor type, manufactured from 1930 to 1955

In non-excited motors, the rotor is made of steel. At synchronous speed it rotates in step with the rotating magnetic field of the stator, so it has an almost-constant magnetic field through it. The external stator field magnetizes the rotor, inducing the magnetic poles needed to turn it. The rotor is made of a high-retentivity steel such as cobalt steel. These are manufactured in permanent magnet, reluctance and hysteresis designs:[5]

Reluctance

These have a rotor consisting of a solid steel casting with projecting (salient) toothed poles. Typically there are fewer rotor than stator poles to minimize torque ripple and to prevent the poles from all aligning simultaneously—a position that cannot generate torque.[3][6] The size of the air gap in the magnetic circuit and thus the reluctance is minimum when the poles are aligned with the (rotating) magnetic field of the stator, and increases with the angle between them. This creates a torque pulling the rotor into alignment with the nearest pole of the stator field. Thus at synchronous speed the rotor is "locked" to the rotating stator field. This cannot start the motor, so the rotor poles usually have squirrel-cage windings embedded in them, to provide torque below synchronous speed. The machine starts as an induction motor until it approaches synchronous speed, when the rotor "pulls in" and locks to the rotating stator field.[7]

Reluctance motor designs have ratings that range from fractional horsepower (a few watts) to about 22 kW. Very small reluctance motors have low torque, and are generally used for instrumentation applications. Moderate torque, multi-horsepower motors use squirrel cage construction with toothed rotors. When used with an adjustable frequency power supply, all motors in the drive system can be controlled at exactly the same speed. The power supply frequency determines motor operating speed.

Hysteresis

These have a solid smooth cylindrical rotor, cast of a high coercivity magnetically "hard" cobalt steel.[6] This material has a wide hysteresis loop (high coercivity), meaning once it is magnetized in a given direction, it requires a large reverse magnetic field to reverse the magnetization. The rotating stator field causes each small volume of the rotor to experience a reversing magnetic field. Because of hysteresis the phase of the magnetization lags behind the phase of the applied field. The result of this is that the axis of the magnetic field induced in the rotor lags behind the axis of the stator field by a constant angle δ, producing a torque as the rotor tries to "catch up" with the stator field. As long as the rotor is below synchronous speed, each particle of the rotor experiences a reversing magnetic field at the "slip" frequency which drives it around its hysteresis loop, causing the rotor field to lag and create torque. There is a 2-pole low reluctance bar structure in the rotor.[6] As the rotor approaches synchronous speed and slip goes to zero, this magnetizes and aligns with the stator field, causing the rotor to "lock" to the rotating stator field.

A major advantage of the hysteresis motor is that since the lag angle δ is independent of speed, it develops constant torque from startup to synchronous speed. Therefore, it is self-starting and doesn't need an induction winding to start it, although many designs do have a squirrel-cage conductive winding structure embedded in the rotor to provide extra torque at start-up.[citation needed]

Hysteresis motors are manufactured in sub-fractional horsepower ratings, primarily as servomotors and timing motors. More expensive than the reluctance type, hysteresis motors are used where precise constant speed is required.[citation needed]

Permanent-magnet

A permanent-magnet synchronous motor (PMSM) uses permanent magnets embedded in the steel rotor to create a constant magnetic field. The stator carries windings connected to an AC supply to produce a rotating magnetic field (as in an asynchronous motor). At synchronous speed the rotor poles lock to the rotating magnetic field. Permanent magnet synchronous motors are similar to brushless DC motors. Neodymium magnets are the most commonly used magnets in these motors. Although in the last few years, due to rapid fluctuation in the prices of neodymium magnets, a lot of research has been looking at ferrite magnets as an alternative.[8] Due to the inherent characteristics of the currently available ferrite magnets, the design of the magnetic circuit of these machines needs to be able to concentrate the magnetic flux, one of the most common strategies is the use of spoke type rotors.[9] Currently, the new machines that use ferrite magnets have lower power density and torque density, when compared with machines that use neodymium magnets.[9]

Permanent magnet motors have been used as gearless elevator motors since 2000.[10]

Most PMSMs require a variable-frequency drive to start.[11][12][13][14][15] However, some incorporate a squirrel cage in the rotor for starting—these are known as line-start or self-starting PMSMs.[16] These are typically used as higher-efficiency replacements for induction motors (owing to the lack of slip), but need to be specified carefully for the application to ensure that synchronous speed is reached and that the system can withstand the torque ripple during starting.

Permanent magnet synchronous motors are mainly controlled using direct torque control[17] and field oriented control.[18] However, these methods suffer from relatively high torque and stator flux ripples.[19] Predictive control and neural network controllers are recently developed to cope with these issues.[19][20]

DC-excited motors

 
DC-excited motor, 1917. The exciter is clearly seen at the rear of the machine.

Usually made in larger sizes (larger than about 1 horsepower or 1 kilowatt) these motors require direct current (DC) supplied to the rotor for excitation. This is most straightforwardly supplied through slip rings, but a brushless AC induction and rectifier arrangement may also be used.[21] The direct current may be supplied from a separate DC source or from a DC generator directly connected to the motor shaft.

Control techniques

A permanent magnet synchronous motor and reluctance motor requires a control system for operating (VFD or servo drive).

There is a large number of control methods for PMSM, which is selected depending on the construction of the electric motor and the scope.

Control methods can be divided into:[22]

Sinusoidal

Trapezoidal

Synchronous speed

The synchronous speed of a synchronous motor is given:[23]
in RPM, by:

 

and in rad·s−1, by:

 

where:

  •   is the frequency of the AC supply current in Hz,
  •   is the number of magnetic poles,
  •   is the number of pole pairs (rarely, planes of commutation),  .

Examples

A single-phase, 4-pole (2-pole-pair) synchronous motor is operating at an AC supply frequency of 50 Hz. The number of pole-pairs is 2, so the synchronous speed is:

 

A three-phase, 12-pole (6-pole-pair) synchronous motor is operating at an AC supply frequency of 60 Hz. The number of pole-pairs is 6, so the synchronous speed is:

 

The number of magnetic poles,  , is equal to the number of coil groups per phase. To determine the number of coil groups per phase in a 3-phase motor, count the number of coils, divide by the number of phases, which is 3. The coils may span several slots in the stator core, making it tedious to count them. For a 3-phase motor, if you count a total of 12 coil groups, it has 4 magnetic poles. For a 12-pole 3-phase machine, there will be 36 coils. The number of magnetic poles in the rotor is equal to the number of magnetic poles in the stator.

Construction

 
Rotor of a large water pump. The slip rings can be seen below the rotor drum.
 
Stator winding of a large water pump

The principal components of a synchronous motor are the stator and the rotor.[24] The stator of synchronous motor and stator of induction motor are similar in construction.[25] With the wound-rotor synchronous doubly fed electric machine as the exception, the stator frame contains wrapper plate.[26] Circumferential ribs and keybars are attached to the wrapper plate.[26] To carry the weight of the machine, frame mounts and footings are required.[26] When the field winding is excited by DC excitation, brushes and slip rings are required to connect to the excitation supply.[27] The field winding can also be excited by a brushless exciter.[28] Cylindrical, round rotors, (also known as non salient pole rotor) are used for up to six poles. In some machines or when a large number of poles are needed, a salient pole rotor is used.[29][30] The construction of synchronous motor is similar to that of a synchronous alternator.[31] Most of the synchronous motors construction uses the stationary armature and rotating field winding. This type of construction as an advantage than DC motor type where the armature used is of rotating type.

Operation

 
The rotating magnetic field is formed from the sum of the magnetic field vectors of the three phases of the stator windings.

The operation of a synchronous motor is due to the interaction of the magnetic fields of the stator and the rotor. Its stator winding, which consists of a 3 phase winding, is provided with a 3 phase supply, and the rotor is provided with a DC supply. The 3 phase stator winding carrying 3 phase currents produces 3 phase rotating magnetic flux (and therefore a rotating magnetic field). The rotor locks in with the rotating magnetic field and rotates along with it. Once the rotor field locks in with the rotating magnetic field, the motor is said to be in synchronization. A single-phase (or two-phase derived from single phase) stator winding is possible, but in this case the direction of rotation is not defined and the machine may start in either direction unless prevented from doing so by the starting arrangements.[32]

Once the motor is in operation, the speed of the motor is dependent only on the supply frequency. When the motor load is increased beyond the breakdown load, the motor falls out of synchronization and the field winding no longer follows the rotating magnetic field. Since the motor cannot produce (synchronous) torque if it falls out of synchronization, practical synchronous motors have a partial or complete squirrel-cage damper (amortisseur) winding to stabilize operation and facilitate starting. Because this winding is smaller than that of an equivalent induction motor and can overheat on long operation, and because large slip-frequency voltages are induced in the rotor excitation winding, synchronous motor protection devices sense this condition and interrupt the power supply (out of step protection).[32]

Starting methods

Above a certain size, synchronous motors are not self-starting motors. This property is due to the inertia of the rotor; it cannot instantly follow the rotation of the magnetic field of the stator. Since a synchronous motor produces no inherent average torque at standstill, it cannot accelerate to synchronous speed without some supplemental mechanism.[3]

Large motors operating on commercial power frequency include a squirrel-cage induction winding which provides sufficient torque for acceleration and which also serves to damp oscillations in motor speed in operation.[3] Once the rotor nears the synchronous speed, the field winding is excited, and the motor pulls into synchronization. Very large motor systems may include a "pony" motor that accelerates the unloaded synchronous machine before load is applied.[33][34] Motors that are electronically controlled can be accelerated from zero speed by changing the frequency of the stator current.[35]

Very small synchronous motors are commonly used in line-powered electric mechanical clocks or timers that use the power line frequency to run the gear mechanism at the correct speed. Such small synchronous motors are able to start without assistance if the moment of inertia of the rotor and its mechanical load is sufficiently small [because the motor] will be accelerated from slip speed up to synchronous speed during an accelerating half cycle of the reluctance torque."[3] Single-phase synchronous motors such as in electric wall clocks can freely rotate in either direction unlike a shaded-pole type. See Shaded-pole synchronous motor for how consistent starting direction is obtained.

The operational economics is an important parameter to address different motor starting methods.[36] Accordingly, the excitation of the rotor is a possible way to solve the motor starting issue.[37] In addition, modern proposed starting methods for large synchronous machines include repetitive polarity inversion of the rotor poles during startup.[38]

Applications, special properties, and advantages

Use as synchronous condenser

 
V-curve of a synchronous machine

By varying the excitation of a synchronous motor, it can be made to operate at lagging, leading and unity power factor. Excitation at which the power factor is unity is termed normal excitation voltage.[39] The magnitude of current at this excitation is minimum.[39] Excitation voltage more than normal excitation is called over excitation voltage, excitation voltage less than normal excitation is called under excitation.[39] When the motor is over excited, the back emf will be greater than the motor terminal voltage. This causes a demagnetizing effect due to armature reaction.[40]

The V curve of a synchronous machine shows armature current as a function of field current. With increasing field current armature current at first decreases, then reaches a minimum, then increases. The minimum point is also the point at which power factor is unity.[41]

This ability to selectively control power factor can be exploited for power factor correction of the power system to which the motor is connected. Since most power systems of any significant size have a net lagging power factor, the presence of overexcited synchronous motors moves the system's net power factor closer to unity, improving efficiency. Such power-factor correction is usually a side effect of motors already present in the system to provide mechanical work, although motors can be run without mechanical load simply to provide power-factor correction. In large industrial plants such as factories the interaction between synchronous motors and other, lagging, loads may be an explicit consideration in the plant's electrical design.[citation needed]

Steady state stability limit

 

where,

  is the torque
  is the torque angle
  is the maximum torque

here,

 

When load is applied, torque angle   increases. When   = 90° the torque will be maximum. If load is applied further then the motor will lose its synchronism, since motor torque will be less than load torque.[42][43] The maximum load torque that can be applied to a motor without losing its synchronism is called steady state stability limit of a synchronous motor.[42]

Other

Synchronous motors are especially useful in applications requiring precise speed or position control:

  • Speed is independent of the load over the operating range of the motor.
  • Speed and position may be accurately controlled using open loop controls (e.g. stepper motors).
  • Low-power applications include positioning machines, where high precision is required, and robot actuators.
  • They will hold their position when a DC current is applied to both the stator and the rotor windings.
  • A clock driven by a synchronous motor is in principle as accurate as the line frequency of its power source. (Although small frequency drifts will occur over any given several hours, grid operators actively adjust line frequency in later periods to compensate, thereby keeping motor-driven clocks accurate; see Utility frequency#Stability.)
  • Record player turntables
  • Increased efficiency in low-speed applications (e.g. ball mills).

Subtypes

See also

References

  1. ^ a b c Fitzgerald, A. E.; Charles Kingsley Jr.; Alexander Kusko (1972). "Chapter 6, Synchronous machines, steady state". Electric Machinery, 3rd Ed. USA: McGraw-Hill. pp. 283–330. Library of Congress Catalog No. 70-137126.
  2. ^ "Permanent Magnet Synchronous Motor".
  3. ^ a b c d e Fitzgerald, A. E.; Charles Kingsley Jr.; Alexander Kusko (1971). "Chapter 11, section 11.2 Starting and Running Performance of Single-phase Induction and Synchronous Motors, Self-starting Reluctance Motors". Electric Machinery, 3rd Ed. USA: McGraw-Hill. pp. 536–538. Library of Congress Catalog No. 70-137126.
  4. ^ James G Stallcup, Stallcup's Generator, Transformer, Motor and Compressor, page 15-13, Jones & Bartlett, 2012 ISBN 1-4496-9519-1.
  5. ^ William Yeadon (ed.), Handbook of Small Electric Motors, McGraw-Hill 2001 ISBN 0-07-072332-X, Chapter 12 "Synchronous Machines"
  6. ^ a b c Gottlieb, Irving M. (1997). Practical electric motor handbook, 2nd Ed. USA: Newnes. pp. 73–76. ISBN 978-0-7506-3638-4.
  7. ^ Michael A. Laughton (2003), "19.2.5 Reluctance motors", Electrical Engineer's Reference Book, Newnes, p. 19/8, ISBN 978-0-7506-4637-6
  8. ^ Eriksson, S; Eklund, P (2020-11-26). "Effect of magnetic properties on performance of electrical machines with ferrite magnets". Journal of Physics D: Applied Physics. 54 (5): 054001. doi:10.1088/1361-6463/abbfc5. ISSN 0022-3727. S2CID 225152358.
  9. ^ a b Luk, Patrick Chi-Kwong; Abdulrahem, Hayder A.; Xia, Bing (November 2020). "Low-cost high-performance ferrite permanent magnet machines in EV applications: A Comprehensive Review". ETransportation. 6: 100080. doi:10.1016/j.etran.2020.100080. ISSN 2590-1168. S2CID 224968436.
  10. ^ Mehri, Darius (18 September 2000). . DesignNews.com. Archived from the original on 29 June 2013. Retrieved 10 May 2016.
  11. ^ R. Islam; I. Husain; A. Fardoun; K. McLaughlin. "Permanent-Magnet Synchronous Motor Magnet Designs With Skewing for Torque Ripple and Cogging Torque Reduction". Industry Applications, IEEE Transactions on. 2009. doi:10.1109/TIA.2008.2009653
  12. ^ Ki-Chan Kim; Seung-Bin Lim; Dae-Hyun Koo; Ju Lee. The Shape Design of Permanent Magnet for Permanent Magnet Synchronous Motor Considering Partial Demagnetization". Magnetics, IEEE Transactions on. 2006. doi:10.1109/TMAG.2006.879077
  13. ^ P. Pillay; R. Krishnan. "Application characteristics of permanent magnet synchronous and brushless DC motors for servo drives". Industry Applications, IEEE Transactions on. 1991. doi:10.1109/28.90357 quote: "The permanent magnet synchronous motor (PMSM) and the brushless DC motor (BDCM) have many similarities; they both have permanent magnets on the rotor and require alternating stator currents to produce constant torque."
  14. ^ Y. Honda; T. Nakamura; T. Higaki; Y. Takeda. "Motor design considerations and test results of an interior permanent magnet synchronous motor for electric vehicles". Industry Applications Conference, 1997. Thirty-Second IAS Annual Meeting, IAS '97., Conference Record of the 1997 IEEE. 1997. doi:10.1109/IAS.1997.643011
  15. ^ M.A. Rahman; Ping Zhou. "Analysis of brushless permanent magnet synchronous motors". Industrial Electronics, IEEE Transactions on. 1996. doi:10.1109/41.491349
  16. ^ Hassanpour Isfahani, Arash; Vaez-Zadeh, Sadegh (Nov 2009). "Line Start Permanent Magnet Synchronous Motors: Challenges and Opportunities". Energy. 34 (11): 1755–1763. doi:10.1016/j.energy.2009.04.022.
  17. ^ Suman, K.; Suneeta, K.; Sasikala, M. (2020-09-09). Direct Torque Controlled induction motor drive with space vector modulation fed with three-level inverter. IEEE Conference Publication. pp. 1–6. doi:10.1109/PEDES.2012.6484405. ISBN 978-1-4673-4508-8. S2CID 25556839. Retrieved 2020-09-23.
  18. ^ Wang, Zheng; Chen, Jian; Cheng, Ming; Chau, K. T. (2020-09-09). "Field-Oriented Control and Direct Torque Control for Paralleled VSIs Fed PMSM Drives With Variable Switching Frequencies". IEEE Transactions on Power Electronics. 31 (3): 2417–2428. doi:10.1109/TPEL.2015.2437893. S2CID 19377123. Retrieved 2020-09-23.
  19. ^ a b Nikbakht, Masoud; Liasi, Sahand Ghaseminejad; Abbaszadeh, Karim; Markadeh, Gholamreza Arab (2020-09-09). An Enhanced Model Predictive Control Strategy to Drive PMSM with reduced Torque and Flux Ripples. IEEE Conference Publication. pp. 1–6. doi:10.1109/PEDSTC49159.2020.9088489. ISBN 978-1-7281-5849-5. S2CID 218564540. Retrieved 2020-09-23.
  20. ^ Kumar, Rajesh; Gupta, R. A.; Bansal, Ajay Kr. (2020-09-09). Identification and Control of PMSM Using Artificial Neural Network. IEEE Conference Publication. pp. 30–35. doi:10.1109/ISIE.2007.4374567. ISBN 978-1-4244-0754-5. S2CID 35896251. Retrieved 2020-09-23.
  21. ^ H.E. Jordan, Energy-Efficient Electric Motors and Their Applications, page 104, Springer, 1994 ISBN 0-306-44698-7
  22. ^ "Permanent Magnet Synchronous Motor". en.engineering-solutions.ru. Retrieved 2019-07-02.
  23. ^ . Electrician's toolbox etc. Archived from the original on 1999-05-08.
  24. ^ "Electrical machine". University of Alberta. Archived from the original on 2013-02-19. Retrieved 2013-01-09.
  25. ^ Finney, David (1988). Variable Frequency Ac Motor Drive System. B (1991 reprint ed.). Peter Peregrinus, Ltd. p. 33. ISBN 978-0-86341-114-4.
  26. ^ a b c Isidor Kerszenbaum, Geoff Klempner (2011-09-20). Handbook of Large Turbo-Generator Operation and Maintenance (Second ed.). Wiley. ISBN 9781118210406.
  27. ^ Gerald B. Kliman, Hamid A. Toliyat (2018-10-03). Handbook of Electric Motors (Second ed.). p. 302. ISBN 9781420030389.
  28. ^ Jordan, Howard E. (1994-08-31). Energy-Efficient Electric Motors and Their Applications. B (Second ed.). Plenum press. p. 104. ISBN 978-0-306-44698-6.
  29. ^ Theraja, B.L. (2005). Electrical technology. II (2010 reprint ed.). S. Chand. p. 1404. ISBN 978-81-219-2437-5.
  30. ^ Isidor Kerszenbaum, Geoff Klempner (2011-09-20). Handbook of Large Turbo-Generator Operation and Maintenance (Second ed.). Wiley. ISBN 9781118210406.
  31. ^ Theraja, B.L. (2005). Electrical technology. II (2010 reprint ed.). S. Chand. p. 1490. ISBN 978-81-219-2437-5.
  32. ^ a b IEEE Standard 141-1993 Recommended Practice for Electric Power Distribution for Industrial Plants pages 227-230
  33. ^ Jerry C. Whitaker, AC Power Systems Handbook, page 192, CRC Press, 2007 ISBN 0-8493-4034-9.
  34. ^ LeDoux, Kurt; Visser, Paul W.; Hulin, J. Dwight; Nguyen, Hien (May 2015). "Starting Large Synchronous Motors in Weak Power Systems". IEEE Transactions on Industry Applications. 51 (3): 2676–2682. doi:10.1109/tia.2014.2373820. ISSN 0093-9994.
  35. ^ David Finney, Variable Frequency AC Motor Drive System, page 32, IEE, 1988 ISBN 0-86341-114-2.
  36. ^ Nevelsteen, J.; Aragon, H. (1989). "Starting of large motors-methods and economics". IEEE Transactions on Industry Applications. 25 (6): 1012–1018. doi:10.1109/28.44236. ISSN 0093-9994.
  37. ^ Schaefer, R.C. (1999). "Excitation control of the synchronous motor". IEEE Transactions on Industry Applications. 35 (3): 694–702. doi:10.1109/28.767025. ISSN 0093-9994.
  38. ^ Perez-Loya, J. J.; Abrahamsson, C.J.D.; Evestedt, Fredrik; Lundin, Urban (2017). "Demonstration of synchronous motor start by rotor polarity inversion". IEEE Transactions on Industrial Electronics. 65 (10): 8271–8273. doi:10.1109/tie.2017.2784342. ISSN 0278-0046. S2CID 46936078.
  39. ^ a b c Bhattacharya, S. K. (2008-08-27). Electrical Machines (third ed.). Tata - McGraw Hill. p. 481. ISBN 9780070669215. OCLC 808866911.
  40. ^ Kosow, Irving L. (September 2007). Electric Machinery And Transformers (second ed.). Pearson Education. p. 230. ISBN 9788131711279. OCLC 222453.
  41. ^ Theraja, B L; Theraja, A K. Electrical technology. II (2010 reprint ed.). S Chand. p. 1524.
  42. ^ a b Dubey, G K. Fundamentals of electrical drives. Narosa publishing chennai. p. 254.
  43. ^ Pillai, S K. A First Course On Electrical Drives (second ed.). New age international. p. 25.

External links

  • Synchronous motor animation

synchronous, motor, synchronous, electric, motor, electric, motor, which, steady, state, rotation, shaft, synchronized, with, frequency, supply, current, rotation, period, exactly, equal, integral, number, cycles, contain, multiphase, electromagnets, stator, m. A synchronous electric motor is an AC electric motor in which at steady state 1 the rotation of the shaft is synchronized with the frequency of the supply current the rotation period is exactly equal to an integral number of AC cycles Synchronous motors contain multiphase AC electromagnets on the stator of the motor that create a magnetic field which rotates in time with the oscillations of the line current The rotor with permanent magnets or electromagnets turns in step with the stator field at the same rate and as a result provides the second synchronized rotating magnet field of any AC motor A synchronous motor is termed doubly fed if it is supplied with independently excited multiphase AC electromagnets on both the rotor and stator 2 Miniature synchronous motor used in analog clocks The rotor is made of permanent magnet Small synchronous motor with integral stepdown gear from a microwave oven The synchronous motor and the induction motor are the most widely used types of AC motors The difference between the two types is that the synchronous motor rotates at a rate locked to the line frequency since it does not rely on current induction to produce the rotor s magnetic field By contrast the induction motor requires slip the rotor must rotate slightly slower than the AC alternations in order to induce current in the rotor winding Small synchronous motors are used in timing applications such as in synchronous clocks timers in appliances tape recorders and precision servomechanisms in which the motor must operate at a precise speed speed accuracy is that of the power line frequency which is carefully controlled in large interconnected grid systems citation needed Synchronous motors are available in self excited sub fractional horsepower sizes 3 to high power industrial sizes 1 In the fractional horsepower range most synchronous motors are used where precise constant speed is required These machines are commonly used in analog electric clocks timers and other devices where correct time is required In higher power industrial sizes the synchronous motor provides two important functions First it is a highly efficient means of converting AC energy to work Second it can operate at leading or unity power factor and thereby provide power factor correction Contents 1 Type 1 1 Non excited 1 1 1 Reluctance 1 1 2 Hysteresis 1 1 3 Permanent magnet 1 2 DC excited motors 2 Control techniques 3 Synchronous speed 3 1 Examples 4 Construction 5 Operation 6 Starting methods 7 Applications special properties and advantages 7 1 Use as synchronous condenser 7 2 Steady state stability limit 7 3 Other 8 Subtypes 9 See also 10 References 11 External linksType EditSynchronous motors fall under the more general category of synchronous machines which also includes the synchronous generator Generator action will be observed if the field poles are driven ahead of the resultant air gap flux by the forward motion of the prime mover Motor action will be observed if the field poles are dragged behind the resultant air gap flux by the retarding torque of a shaft load 1 There are two major types of synchronous motors depending on how the rotor is magnetized non excited and direct current excited 4 Non excited Edit Single phase 60 Hz 1800 RPM synchronous motor for Teletype machine non excited rotor type manufactured from 1930 to 1955 In non excited motors the rotor is made of steel At synchronous speed it rotates in step with the rotating magnetic field of the stator so it has an almost constant magnetic field through it The external stator field magnetizes the rotor inducing the magnetic poles needed to turn it The rotor is made of a high retentivity steel such as cobalt steel These are manufactured in permanent magnet reluctance and hysteresis designs 5 Reluctance Edit Main article Reluctance motor These have a rotor consisting of a solid steel casting with projecting salient toothed poles Typically there are fewer rotor than stator poles to minimize torque ripple and to prevent the poles from all aligning simultaneously a position that cannot generate torque 3 6 The size of the air gap in the magnetic circuit and thus the reluctance is minimum when the poles are aligned with the rotating magnetic field of the stator and increases with the angle between them This creates a torque pulling the rotor into alignment with the nearest pole of the stator field Thus at synchronous speed the rotor is locked to the rotating stator field This cannot start the motor so the rotor poles usually have squirrel cage windings embedded in them to provide torque below synchronous speed The machine starts as an induction motor until it approaches synchronous speed when the rotor pulls in and locks to the rotating stator field 7 Reluctance motor designs have ratings that range from fractional horsepower a few watts to about 22 kW Very small reluctance motors have low torque and are generally used for instrumentation applications Moderate torque multi horsepower motors use squirrel cage construction with toothed rotors When used with an adjustable frequency power supply all motors in the drive system can be controlled at exactly the same speed The power supply frequency determines motor operating speed Hysteresis Edit These have a solid smooth cylindrical rotor cast of a high coercivity magnetically hard cobalt steel 6 This material has a wide hysteresis loop high coercivity meaning once it is magnetized in a given direction it requires a large reverse magnetic field to reverse the magnetization The rotating stator field causes each small volume of the rotor to experience a reversing magnetic field Because of hysteresis the phase of the magnetization lags behind the phase of the applied field The result of this is that the axis of the magnetic field induced in the rotor lags behind the axis of the stator field by a constant angle d producing a torque as the rotor tries to catch up with the stator field As long as the rotor is below synchronous speed each particle of the rotor experiences a reversing magnetic field at the slip frequency which drives it around its hysteresis loop causing the rotor field to lag and create torque There is a 2 pole low reluctance bar structure in the rotor 6 As the rotor approaches synchronous speed and slip goes to zero this magnetizes and aligns with the stator field causing the rotor to lock to the rotating stator field A major advantage of the hysteresis motor is that since the lag angle d is independent of speed it develops constant torque from startup to synchronous speed Therefore it is self starting and doesn t need an induction winding to start it although many designs do have a squirrel cage conductive winding structure embedded in the rotor to provide extra torque at start up citation needed Hysteresis motors are manufactured in sub fractional horsepower ratings primarily as servomotors and timing motors More expensive than the reluctance type hysteresis motors are used where precise constant speed is required citation needed Permanent magnet Edit A permanent magnet synchronous motor PMSM uses permanent magnets embedded in the steel rotor to create a constant magnetic field The stator carries windings connected to an AC supply to produce a rotating magnetic field as in an asynchronous motor At synchronous speed the rotor poles lock to the rotating magnetic field Permanent magnet synchronous motors are similar to brushless DC motors Neodymium magnets are the most commonly used magnets in these motors Although in the last few years due to rapid fluctuation in the prices of neodymium magnets a lot of research has been looking at ferrite magnets as an alternative 8 Due to the inherent characteristics of the currently available ferrite magnets the design of the magnetic circuit of these machines needs to be able to concentrate the magnetic flux one of the most common strategies is the use of spoke type rotors 9 Currently the new machines that use ferrite magnets have lower power density and torque density when compared with machines that use neodymium magnets 9 Permanent magnet motors have been used as gearless elevator motors since 2000 10 Most PMSMs require a variable frequency drive to start 11 12 13 14 15 However some incorporate a squirrel cage in the rotor for starting these are known as line start or self starting PMSMs 16 These are typically used as higher efficiency replacements for induction motors owing to the lack of slip but need to be specified carefully for the application to ensure that synchronous speed is reached and that the system can withstand the torque ripple during starting Permanent magnet synchronous motors are mainly controlled using direct torque control 17 and field oriented control 18 However these methods suffer from relatively high torque and stator flux ripples 19 Predictive control and neural network controllers are recently developed to cope with these issues 19 20 DC excited motors Edit DC excited motor 1917 The exciter is clearly seen at the rear of the machine Usually made in larger sizes larger than about 1 horsepower or 1 kilowatt these motors require direct current DC supplied to the rotor for excitation This is most straightforwardly supplied through slip rings but a brushless AC induction and rectifier arrangement may also be used 21 The direct current may be supplied from a separate DC source or from a DC generator directly connected to the motor shaft Control techniques EditA permanent magnet synchronous motor and reluctance motor requires a control system for operating VFD or servo drive There is a large number of control methods for PMSM which is selected depending on the construction of the electric motor and the scope Control methods can be divided into 22 Sinusoidal Scalar Vector FOC DTC Trapezoidal Open loop Closed loop with and without Hall sensor Synchronous speed EditThe synchronous speed of a synchronous motor is given 23 in RPM by N s 60 f P 120 f p displaystyle N s 60 frac f P 120 frac f p and in rad s 1 by w s 2 p f P 4 p f p displaystyle omega s 2 pi frac f P 4 pi frac f p where f displaystyle f is the frequency of the AC supply current in Hz p displaystyle p is the number of magnetic poles P displaystyle P is the number of pole pairs rarely planes of commutation P p 2 displaystyle P p 2 Examples Edit A single phase 4 pole 2 pole pair synchronous motor is operating at an AC supply frequency of 50 Hz The number of pole pairs is 2 so the synchronous speed is N s 60 50 2 1500 rpm displaystyle N s 60 times frac 50 2 1500 text rpm A three phase 12 pole 6 pole pair synchronous motor is operating at an AC supply frequency of 60 Hz The number of pole pairs is 6 so the synchronous speed is N s 60 60 6 600 rpm displaystyle N s 60 times frac 60 6 600 text rpm The number of magnetic poles p displaystyle p is equal to the number of coil groups per phase To determine the number of coil groups per phase in a 3 phase motor count the number of coils divide by the number of phases which is 3 The coils may span several slots in the stator core making it tedious to count them For a 3 phase motor if you count a total of 12 coil groups it has 4 magnetic poles For a 12 pole 3 phase machine there will be 36 coils The number of magnetic poles in the rotor is equal to the number of magnetic poles in the stator Construction Edit Rotor of a large water pump The slip rings can be seen below the rotor drum Stator winding of a large water pump The principal components of a synchronous motor are the stator and the rotor 24 The stator of synchronous motor and stator of induction motor are similar in construction 25 With the wound rotor synchronous doubly fed electric machine as the exception the stator frame contains wrapper plate 26 Circumferential ribs and keybars are attached to the wrapper plate 26 To carry the weight of the machine frame mounts and footings are required 26 When the field winding is excited by DC excitation brushes and slip rings are required to connect to the excitation supply 27 The field winding can also be excited by a brushless exciter 28 Cylindrical round rotors also known as non salient pole rotor are used for up to six poles In some machines or when a large number of poles are needed a salient pole rotor is used 29 30 The construction of synchronous motor is similar to that of a synchronous alternator 31 Most of the synchronous motors construction uses the stationary armature and rotating field winding This type of construction as an advantage than DC motor type where the armature used is of rotating type Operation Edit The rotating magnetic field is formed from the sum of the magnetic field vectors of the three phases of the stator windings The operation of a synchronous motor is due to the interaction of the magnetic fields of the stator and the rotor Its stator winding which consists of a 3 phase winding is provided with a 3 phase supply and the rotor is provided with a DC supply The 3 phase stator winding carrying 3 phase currents produces 3 phase rotating magnetic flux and therefore a rotating magnetic field The rotor locks in with the rotating magnetic field and rotates along with it Once the rotor field locks in with the rotating magnetic field the motor is said to be in synchronization A single phase or two phase derived from single phase stator winding is possible but in this case the direction of rotation is not defined and the machine may start in either direction unless prevented from doing so by the starting arrangements 32 Once the motor is in operation the speed of the motor is dependent only on the supply frequency When the motor load is increased beyond the breakdown load the motor falls out of synchronization and the field winding no longer follows the rotating magnetic field Since the motor cannot produce synchronous torque if it falls out of synchronization practical synchronous motors have a partial or complete squirrel cage damper amortisseur winding to stabilize operation and facilitate starting Because this winding is smaller than that of an equivalent induction motor and can overheat on long operation and because large slip frequency voltages are induced in the rotor excitation winding synchronous motor protection devices sense this condition and interrupt the power supply out of step protection 32 Starting methods EditAbove a certain size synchronous motors are not self starting motors This property is due to the inertia of the rotor it cannot instantly follow the rotation of the magnetic field of the stator Since a synchronous motor produces no inherent average torque at standstill it cannot accelerate to synchronous speed without some supplemental mechanism 3 Large motors operating on commercial power frequency include a squirrel cage induction winding which provides sufficient torque for acceleration and which also serves to damp oscillations in motor speed in operation 3 Once the rotor nears the synchronous speed the field winding is excited and the motor pulls into synchronization Very large motor systems may include a pony motor that accelerates the unloaded synchronous machine before load is applied 33 34 Motors that are electronically controlled can be accelerated from zero speed by changing the frequency of the stator current 35 Very small synchronous motors are commonly used in line powered electric mechanical clocks or timers that use the power line frequency to run the gear mechanism at the correct speed Such small synchronous motors are able to start without assistance if the moment of inertia of the rotor and its mechanical load is sufficiently small because the motor will be accelerated from slip speed up to synchronous speed during an accelerating half cycle of the reluctance torque 3 Single phase synchronous motors such as in electric wall clocks can freely rotate in either direction unlike a shaded pole type See Shaded pole synchronous motor for how consistent starting direction is obtained The operational economics is an important parameter to address different motor starting methods 36 Accordingly the excitation of the rotor is a possible way to solve the motor starting issue 37 In addition modern proposed starting methods for large synchronous machines include repetitive polarity inversion of the rotor poles during startup 38 Applications special properties and advantages EditUse as synchronous condenser Edit Main article Synchronous condenser V curve of a synchronous machine By varying the excitation of a synchronous motor it can be made to operate at lagging leading and unity power factor Excitation at which the power factor is unity is termed normal excitation voltage 39 The magnitude of current at this excitation is minimum 39 Excitation voltage more than normal excitation is called over excitation voltage excitation voltage less than normal excitation is called under excitation 39 When the motor is over excited the back emf will be greater than the motor terminal voltage This causes a demagnetizing effect due to armature reaction 40 The V curve of a synchronous machine shows armature current as a function of field current With increasing field current armature current at first decreases then reaches a minimum then increases The minimum point is also the point at which power factor is unity 41 This ability to selectively control power factor can be exploited for power factor correction of the power system to which the motor is connected Since most power systems of any significant size have a net lagging power factor the presence of overexcited synchronous motors moves the system s net power factor closer to unity improving efficiency Such power factor correction is usually a side effect of motors already present in the system to provide mechanical work although motors can be run without mechanical load simply to provide power factor correction In large industrial plants such as factories the interaction between synchronous motors and other lagging loads may be an explicit consideration in the plant s electrical design citation needed Steady state stability limit Edit T T max sin d displaystyle mathbf T mathbf T text max sin delta where T displaystyle mathbf T is the torque d displaystyle delta is the torque angle T max displaystyle mathbf T text max is the maximum torquehere T max 3 V E X s w s displaystyle mathbf T text max frac mathbf 3 mathbf V mathbf E mathbf X s omega s When load is applied torque angle d displaystyle delta increases When d displaystyle delta 90 the torque will be maximum If load is applied further then the motor will lose its synchronism since motor torque will be less than load torque 42 43 The maximum load torque that can be applied to a motor without losing its synchronism is called steady state stability limit of a synchronous motor 42 Other Edit Synchronous motors are especially useful in applications requiring precise speed or position control Speed is independent of the load over the operating range of the motor Speed and position may be accurately controlled using open loop controls e g stepper motors Low power applications include positioning machines where high precision is required and robot actuators They will hold their position when a DC current is applied to both the stator and the rotor windings A clock driven by a synchronous motor is in principle as accurate as the line frequency of its power source Although small frequency drifts will occur over any given several hours grid operators actively adjust line frequency in later periods to compensate thereby keeping motor driven clocks accurate see Utility frequency Stability Record player turntables Increased efficiency in low speed applications e g ball mills Subtypes EditAC Polyphase synchronous motors Stepper motor may be synchronous or not Synchronous brushless wound rotor doubly fed electric machineSee also EditClock drive Doubly fed electric machine Short circuit ratioReferences Edit a b c Fitzgerald A E Charles Kingsley Jr Alexander Kusko 1972 Chapter 6 Synchronous machines steady state Electric Machinery 3rd Ed USA McGraw Hill pp 283 330 Library of Congress Catalog No 70 137126 Permanent Magnet Synchronous Motor a b c d e Fitzgerald A E Charles Kingsley Jr Alexander Kusko 1971 Chapter 11 section 11 2 Starting and Running Performance of Single phase Induction and Synchronous Motors Self starting Reluctance Motors Electric Machinery 3rd Ed USA McGraw Hill pp 536 538 Library of Congress Catalog No 70 137126 James G Stallcup Stallcup s Generator Transformer Motor and Compressor page 15 13 Jones amp Bartlett 2012 ISBN 1 4496 9519 1 William Yeadon ed Handbook of Small Electric Motors McGraw Hill 2001 ISBN 0 07 072332 X Chapter 12 Synchronous Machines a b c Gottlieb Irving M 1997 Practical electric motor handbook 2nd Ed USA Newnes pp 73 76 ISBN 978 0 7506 3638 4 Michael A Laughton 2003 19 2 5 Reluctance motors Electrical Engineer s Reference Book Newnes p 19 8 ISBN 978 0 7506 4637 6 Eriksson S Eklund P 2020 11 26 Effect of magnetic properties on performance of electrical machines with ferrite magnets Journal of Physics D Applied Physics 54 5 054001 doi 10 1088 1361 6463 abbfc5 ISSN 0022 3727 S2CID 225152358 a b Luk Patrick Chi Kwong Abdulrahem Hayder A Xia Bing November 2020 Low cost high performance ferrite permanent magnet machines in EV applications A Comprehensive Review ETransportation 6 100080 doi 10 1016 j etran 2020 100080 ISSN 2590 1168 S2CID 224968436 Mehri Darius 18 September 2000 Belts Lift Performance DesignNews com Archived from the original on 29 June 2013 Retrieved 10 May 2016 R Islam I Husain A Fardoun K McLaughlin Permanent Magnet Synchronous Motor Magnet Designs With Skewing for Torque Ripple and Cogging Torque Reduction Industry Applications IEEE Transactions on 2009 doi 10 1109 TIA 2008 2009653 Ki Chan Kim Seung Bin Lim Dae Hyun Koo Ju Lee The Shape Design of Permanent Magnet for Permanent Magnet Synchronous Motor Considering Partial Demagnetization Magnetics IEEE Transactions on 2006 doi 10 1109 TMAG 2006 879077 P Pillay R Krishnan Application characteristics of permanent magnet synchronous and brushless DC motors for servo drives Industry Applications IEEE Transactions on 1991 doi 10 1109 28 90357 quote The permanent magnet synchronous motor PMSM and the brushless DC motor BDCM have many similarities they both have permanent magnets on the rotor and require alternating stator currents to produce constant torque Y Honda T Nakamura T Higaki Y Takeda Motor design considerations and test results of an interior permanent magnet synchronous motor for electric vehicles Industry Applications Conference 1997 Thirty Second IAS Annual Meeting IAS 97 Conference Record of the 1997 IEEE 1997 doi 10 1109 IAS 1997 643011 M A Rahman Ping Zhou Analysis of brushless permanent magnet synchronous motors Industrial Electronics IEEE Transactions on 1996 doi 10 1109 41 491349 Hassanpour Isfahani Arash Vaez Zadeh Sadegh Nov 2009 Line Start Permanent Magnet Synchronous Motors Challenges and Opportunities Energy 34 11 1755 1763 doi 10 1016 j energy 2009 04 022 Suman K Suneeta K Sasikala M 2020 09 09 Direct Torque Controlled induction motor drive with space vector modulation fed with three level inverter IEEE Conference Publication pp 1 6 doi 10 1109 PEDES 2012 6484405 ISBN 978 1 4673 4508 8 S2CID 25556839 Retrieved 2020 09 23 Wang Zheng Chen Jian Cheng Ming Chau K T 2020 09 09 Field Oriented Control and Direct Torque Control for Paralleled VSIs Fed PMSM Drives With Variable Switching Frequencies IEEE Transactions on Power Electronics 31 3 2417 2428 doi 10 1109 TPEL 2015 2437893 S2CID 19377123 Retrieved 2020 09 23 a b Nikbakht Masoud Liasi Sahand Ghaseminejad Abbaszadeh Karim Markadeh Gholamreza Arab 2020 09 09 An Enhanced Model Predictive Control Strategy to Drive PMSM with reduced Torque and Flux Ripples IEEE Conference Publication pp 1 6 doi 10 1109 PEDSTC49159 2020 9088489 ISBN 978 1 7281 5849 5 S2CID 218564540 Retrieved 2020 09 23 Kumar Rajesh Gupta R A Bansal Ajay Kr 2020 09 09 Identification and Control of PMSM Using Artificial Neural Network IEEE Conference Publication pp 30 35 doi 10 1109 ISIE 2007 4374567 ISBN 978 1 4244 0754 5 S2CID 35896251 Retrieved 2020 09 23 H E Jordan Energy Efficient Electric Motors and Their Applications page 104 Springer 1994 ISBN 0 306 44698 7 Permanent Magnet Synchronous Motor en engineering solutions ru Retrieved 2019 07 02 Motor speed Electrician s toolbox etc Archived from the original on 1999 05 08 Electrical machine University of Alberta Archived from the original on 2013 02 19 Retrieved 2013 01 09 Finney David 1988 Variable Frequency Ac Motor Drive System B 1991 reprint ed Peter Peregrinus Ltd p 33 ISBN 978 0 86341 114 4 a b c Isidor Kerszenbaum Geoff Klempner 2011 09 20 Handbook of Large Turbo Generator Operation and Maintenance Second ed Wiley ISBN 9781118210406 Gerald B Kliman Hamid A Toliyat 2018 10 03 Handbook of Electric Motors Second ed p 302 ISBN 9781420030389 Jordan Howard E 1994 08 31 Energy Efficient Electric Motors and Their Applications B Second ed Plenum press p 104 ISBN 978 0 306 44698 6 Theraja B L 2005 Electrical technology II 2010 reprint ed S Chand p 1404 ISBN 978 81 219 2437 5 Isidor Kerszenbaum Geoff Klempner 2011 09 20 Handbook of Large Turbo Generator Operation and Maintenance Second ed Wiley ISBN 9781118210406 Theraja B L 2005 Electrical technology II 2010 reprint ed S Chand p 1490 ISBN 978 81 219 2437 5 a b IEEE Standard 141 1993 Recommended Practice for Electric Power Distribution for Industrial Plants pages 227 230 Jerry C Whitaker AC Power Systems Handbook page 192 CRC Press 2007 ISBN 0 8493 4034 9 LeDoux Kurt Visser Paul W Hulin J Dwight Nguyen Hien May 2015 Starting Large Synchronous Motors in Weak Power Systems IEEE Transactions on Industry Applications 51 3 2676 2682 doi 10 1109 tia 2014 2373820 ISSN 0093 9994 David Finney Variable Frequency AC Motor Drive System page 32 IEE 1988 ISBN 0 86341 114 2 Nevelsteen J Aragon H 1989 Starting of large motors methods and economics IEEE Transactions on Industry Applications 25 6 1012 1018 doi 10 1109 28 44236 ISSN 0093 9994 Schaefer R C 1999 Excitation control of the synchronous motor IEEE Transactions on Industry Applications 35 3 694 702 doi 10 1109 28 767025 ISSN 0093 9994 Perez Loya J J Abrahamsson C J D Evestedt Fredrik Lundin Urban 2017 Demonstration of synchronous motor start by rotor polarity inversion IEEE Transactions on Industrial Electronics 65 10 8271 8273 doi 10 1109 tie 2017 2784342 ISSN 0278 0046 S2CID 46936078 a b c Bhattacharya S K 2008 08 27 Electrical Machines third ed Tata McGraw Hill p 481 ISBN 9780070669215 OCLC 808866911 Kosow Irving L September 2007 Electric Machinery And Transformers second ed Pearson Education p 230 ISBN 9788131711279 OCLC 222453 Theraja B L Theraja A K Electrical technology II 2010 reprint ed S Chand p 1524 a b Dubey G K Fundamentals of electrical drives Narosa publishing chennai p 254 Pillai S K A First Course On Electrical Drives second ed New age international p 25 External links Edit Wikimedia Commons has media related to Synchronous motors Synchronous motor animation Retrieved from https en wikipedia org w index php title Synchronous motor amp oldid 1134562938, wikipedia, wiki, book, books, library,