A strain gauge (also spelled strain gage) is a device used to measure strain on an object. Invented by Edward E. Simmons and Arthur C. Ruge in 1938, the most common type of strain gauge consists of an insulating flexible backing which supports a metallic foil pattern. The gauge is attached to the object by a suitable adhesive, such as cyanoacrylate.[1] As the object is deformed, the foil is deformed, causing its electrical resistance to change. This resistance change, usually measured using a Wheatstone bridge, is related to the strain by the quantity known as the gauge factor.

Typical foil strain gauge; the blue region is conductive and resistance is measured from one large blue pad to the other. The gauge is far more sensitive to strain in the vertical direction than in the horizontal direction. The markings outside the active area help to align the gauge during installation.

History edit

Edward E. Simmons and Professor Arthur C. Ruge independently invented the strain gauge.

Simmons was involved in a research project by Dätwyler and Clark at Caltech between 1936 and 1938. They researched the stress-strain behavior of metals under shock loads. Simmons came up with an original way to measure the force introduced into the sample by equipping a dynamometer with fine resistance wires.

Arthur C. Ruge, a professor at MIT, on the other hand, conducted research in seismology. He tried to analyze the behavior of a model water tank installed on a vibration table.  He was not able to utilize the standard optical strain measurement methods of his time due to the small scale and low strains in his model. Professor Ruge (and his assistant J. Hanns Meier) had the epiphany of measuring the resistance change caused by strain in metallic wires cemented on the thin walls of the water tank model.

The development of the strain gauge was essentially just a byproduct of other research projects. Edward E. Simmons and Professor Arthur C. Ruge developed a widely used and useful measurement tool due to the lack of an alternative at their times. Arthur C. Ruge realized the commercial utility of the strain gauge. His employer at MIT waived all claims on the right of the invention, as they did not predict the economic and large-scale usage potential. This prediction turned out to be false. The strain gauge applications were quickly gaining traction as they served to indirectly detect all other quantities that induce strain. Additionally, they were simple to install by the scientists, did not cause any obstruction or property changes to the observed object and thus falsifying the measurement results. Probably the last and most important property was the ease of transmission of the electrical output signal.[2]

Physical operation edit

 
An unmounted resistive foil strain gauge

A strain gauge takes advantage of the physical property of electrical conductance and its dependence on the conductor's geometry. When an electrical conductor is stretched within the limits of its elasticity such that it does not break or permanently deform, it will become narrower and longer, which increases its electrical resistance end-to-end. Conversely, when a conductor is compressed such that it does not buckle, it will broaden and shorten, which decreases its electrical resistance end-to-end. From the measured electrical resistance of the strain gauge, the amount of induced stress may be inferred.

A typical strain gauge arranges a long, thin conductive strip in a zig-zag pattern of parallel lines. This does not increase the sensitivity, since the percentage change in resistance for a given strain for the entire zig-zag is the same as for any single trace. A single linear trace would have to be extremely thin, hence liable to overheating (which would change its resistance and cause it to expand), or would need to be operated at a much lower voltage, making it difficult to measure resistance changes accurately.

Gauge factor edit

The gauge factor   is defined as:

 

where

  is the change in resistance caused by strain,
  is the resistance of the undeformed gauge, and
  is strain.

For common metallic foil gauges, the gauge factor is usually a little over 2.[3] For a single active gauge and three dummy resistors of the same resistance about the active gauge in a balanced Wheatstone bridge configuration, the output sensor voltage   from the bridge is approximately:

 

where

  is the bridge excitation voltage.

Foil gauges typically have active areas of about 2–10 mm2 in size. With careful installation, the correct gauge, and the correct adhesive, strains up to at least 10% can be measured.

In practice edit

 
Visualization of the working concept behind the strain gauge on a beam under exaggerated bending

An excitation voltage is applied to input leads of the gauge network, and a voltage reading is taken from the output leads. Typical input voltages are 5 V or 12 V and typical output readings are in millivolts.

Foil strain gauges are used in many situations. Different applications place different requirements on the gauge. In most cases the orientation of the strain gauge is significant.

Gauges attached to a load cell would normally be expected to remain stable over a period of years, if not decades; while those used to measure response in a dynamic experiment may only need to remain attached to the object for a few days, be energized for less than an hour, and operate for less than a second.

Strain gauges are attached to the substrate with a special glue. The type of glue depends on the required lifetime of the measurement system. For short term measurements (up to some weeks) cyanoacrylate glue is appropriate, for long lasting installation epoxy glue is required. Usually epoxy glue requires high temperature curing (at about 80-100 °C). The preparation of the surface where the strain gauge is to be glued is of the utmost importance. The surface must be smoothed (e.g. with very fine sand paper), deoiled with solvents, the solvent traces must then be removed and the strain gauge must be glued immediately after this to avoid oxidation or pollution of the prepared area. If these steps are not followed the strain gauge binding to the surface may be unreliable and unpredictable measurement errors may be generated.

Strain gauge based technology is used commonly in the manufacture of pressure sensors. The gauges used in pressure sensors themselves are commonly made from silicon, polysilicon, metal film, thick film, and bonded foil.

Variations in temperature edit

Variations in temperature will cause a multitude of effects. The object will change in size by thermal expansion, which will be detected as a strain by the gauge. Resistance of the gauge will change, and resistance of the connecting wires will change.

Most strain gauges are made from a constantan alloy.[4] Various constantan alloys and Karma alloys have been designed so that the temperature effects on the resistance of the strain gauge itself largely cancel out the resistance change of the gauge due to the thermal expansion of the object under test. Because different materials have different amounts of thermal expansion, self-temperature compensation (STC) requires selecting a particular alloy matched to the material of the object under test.

Strain gauges that are not self-temperature-compensated (such as isoelastic alloy) can be temperature compensated by use of the dummy gauge technique. A dummy gauge (identical to the active strain gauge) is installed on an unstrained sample of the same material as the test specimen. The sample with the dummy gauge is placed in thermal contact with the test specimen, adjacent to the active gauge. The dummy gauge is wired into a Wheatstone bridge on an adjacent arm to the active gauge so that the temperature effects on the active and dummy gauges cancel each other.[5] (Murphy's law was originally coined in response to a set of gauges being incorrectly wired into a Wheatstone bridge.[6])

Every material reacts when it heats up or when it cools down. This will cause strain gauges to register a deformation in the material which will make it change signal. To prevent this from happening strain gauges are made so they will compensate this change due to temperature. Dependent on the material of the surface where the strain gauge is assembled on, a different expansion can be measured.

Temperature effects on the lead wires can be cancelled by using a "3-wire bridge" or a "4-wire ohm circuit"[7] (also called a "4-wire Kelvin connection").

In any case it is a good engineering practice to keep the Wheatstone bridge voltage drive low enough to avoid the self heating of the strain gauge. The self heating of the strain gauge depends on its mechanical characteristic (large strain gauges are less prone to self heating). Low voltage drive levels of the bridge reduce the sensitivity of the overall system.

Applications edit

Structural health monitoring edit

Structural health monitoring (SHM) is used to monitor structures after their completion. To prevent failures, strain gauges are used to detect and locate damages and creep. A specific example is the monitoring of bridge cables increasing safety by detecting possible damages. Also, the bridge's behavior to unusual loads can be analyzed such as special heavy-duty transports.

Biological measurements edit

Measuring the strain of skin can provide a multitude of biomechanic measurements such as posture, joint rotation, respiration and swelling both in humans and other animals. Resistive foil strain gauges are seldom used for these applications, however, due to their low strain limit. Instead, soft and deformable strain gauges are often attached to a host garment, to make it simple to apply the sensor to the correct part of the body, though sometimes they are attached directly to the skin. Typically in these applications, such soft strain gauges [1] are known as stretch sensors. For medical use, the sensors must be accurate and repeatable which typically requires the use of capacitive stretch sensors.

Predictive maintenance edit

Many objects and materials in industrial applications have a finite life. To improve their lifetime and cost of ownership, predictive maintenance principles are used. Strain gauges can be used to monitor the strain as an indicator of fatigue in materials to enable software systems to predict when certain components need to be replaced or serviced. Resistive foil gauges can be used to instrument stiff materials like metals, ceramics, composites and similar, whereas highly elastic strain gauges are used to monitor softer materials such as rubber, plastics, textiles and the like. [2]

Aviation edit

In aviation, strain gauges are the standard approach to measuring the structural load and calculating wing deflection. Strain gauges are fixed in several locations on the aircraft. However, deflection measurement systems have been shown to measure reliable strains remotely. This reduces instrumentation weight on the aircraft and thus is replacing the strain gauge.[8]

Repurposing edit

There are also applications where it isn't first obvious that you would measure strain to get to the wanted result. So for example in the detection of intruders on certain structures, strain gauges can be used to detect the presence of such an intruder. This is done by measuring the slight change in strain of the said structure.[9]

Errors and compensations edit

  • Zero Offset - If the impedance of the four gauge arms are not exactly the same after bonding the gauge to the force collector, there will be a zero offset which can be compensated by introducing a parallel resistor to one or more of the gauge arms.
  • Temperature coefficient of gauge factor (TCGF) is the change of sensitivity of the device to strain with change in temperature. This is generally compensated for by the introduction of a fixed resistance in the input leg, whereby the effective supplied voltage will decrease with a temperature increase, compensating for the increase in sensitivity with the temperature increase. This is known as modulus compensation in transducer circuits. As the temperature rises the load cell element becomes more elastic and therefore under a constant load will deform more and lead to an increase in output; but the load is still the same. The clever bit in all this is that the resistor in the bridge supply must be a temperature sensitive resistor that is matched to both the material to which the gauge is bonded and also to the gauge element material. The value of that resistor is dependent on both of those values and can be calculated. In simple terms if the output increases then the resistor value also increase thereby reducing the net voltage to the transducer. Get the resistor value right and you will see no change.
  • Zero shift with temperature - If the TCGF of each gauge is not the same, there will be a zero shift with temperature. This is also caused by anomalies in the force collector. This is usually compensated for with one or more resistors strategically placed in the compensation network.
  • Linearity is an error whereby the sensitivity changes across the pressure range. This is commonly a function of the force collection thickness selection for the intended pressure and the quality of the bonding.
  • Hysteresis is an error of return to zero after pressure excursion.
  • Repeatability - This error is sometimes tied-in with hysteresis but is across the pressure range.
  • Electromagnetic interference (EMI)-induced errors - As the output voltage of strain gauges is in the mV range, even μV if the Wheatstone bridge voltage drive is kept low to avoid self heating of the element, special care must be taken in output signal amplification to avoid amplifying also the superimposed noise. A solution which is frequently adopted is to use "carrier frequency" amplifiers, which convert the voltage variation into a frequency variation (as in voltage-controlled oscillators) and have a narrow bandwidth, thus reducing out of band EMI.
  • Overloading – If a strain gauge is loaded beyond its design limit (measured in microstrain) its performance degrades and can not be recovered. Normally good engineering practice suggests not to stress strain gauges beyond ±3000 microstrain.
  • Humidity – If the wires connecting the strain gauge to the signal conditioner are not protected against humidity, such as bare wire, corrosion can occur, leading to parasitic resistance. This can allow currents to flow between the wires and the substrate to which the strain gauge is glued, or between the two wires directly, introducing an error which competes with the current flowing through the strain gauge. For this reason, high-current, low-resistance strain gauges (120 ohm) are less prone to this type of error. To avoid this error it is sufficient to protect the strain gauges wires with insulating enamel (e.g., epoxy or polyurethane type). Strain gauges with unprotected wires may be used only in a dry laboratory environment but not in an industrial one.

In some applications, strain gauges add mass and damping to the vibration profiles of the hardware they are intended to measure. In the turbomachinery industry, one used alternative to strain gauge technology in the measurement of vibrations on rotating hardware is the non-intrusive stress measurement system, which allows measurement of blade vibrations without any blade or disc-mounted hardware...

Geometries of strain gauges edit

 
Geometries of strain gauges

The following different kind of strain gauges are available in the market:

  • Linear strain gauges
  • Membrane Rosette strain gauges
  • Double linear strain gauges
  • Full bridge strain gauges
  • Shear strain gauges
  • Half bridge strain gauges
  • Column strain gauges
  • 45°-Rosette (3 measuring directions)
  • 90°-Rosette (2 measuring directions).

Other types edit

Strain Gauge measurement devices are prone to drift problems. Additionally, their manufacturing requires precise requirements during all the production steps. So there are multiple different ways of also measuring strain.[2]

  • For measurements of small strain, semiconductor strain gauges, so called piezoresistors, are often preferred over foil gauges. A semiconductor gauge usually has a larger gauge factor than a foil gauge. Semiconductor gauges tend to be more expensive, more sensitive to temperature changes, and are more fragile than foil gauges.
  • Nanoparticle-based strain gauges emerge as a new promising technology. These resistive sensors whose active area is made by an assembly of conductive nanoparticles, such as gold or carbon, combine a high gauge factor, a large deformation range and a small electrical consumption due to their high impedance.
  • In biological measurements, especially blood flow and tissue swelling, a variant called mercury-in-rubber strain gauge is used. This kind of strain gauge consists of a small amount of liquid mercury enclosed in a small rubber tube, which is applied around e.g., a toe or leg. Swelling of the body part results in stretching of the tube, making it both longer and thinner, which increases electrical resistance.
  • Fiber optic sensing can be employed to measure strain along an optical fiber. Measurements can be distributed along the fiber, or taken at predetermined points on the fiber. The 2010 America's Cup boats Alinghi 5 and USA-17 both employ embedded sensors of this type.[10]
 
Example of non-contact strain measurement using digital image correlation on a material testing coupon showing moving strain structures called Lüders bands
  • Other optical measuring techniques can be used to measure strains like electronic speckle pattern interferometry or digital image correlation.
  • Microscale strain gauges are widely used in microelectromechanical systems (MEMS) to measure strains such as those induced by force, acceleration, pressure or sound.[11] As example, airbags in cars are often triggered with MEMS accelerometers. As alternative to piezo-resistant strain gauges, integrated optical ring resonators may be used to measure strain in microoptoelectromechanical systems (MOEMS).[12]
  • Capacitive strain gauges use a variable capacitor to indicate the level of mechanical deformation.
  • Vibrating wire strain gauges are used in geotechnical and civil engineering applications. The gauge consists of a vibrating, tensioned wire. The strain is calculated by measuring the resonant frequency of the wire (an increase in tension increases the resonant frequency).
  • Quartz crystal strain gauges are also used in geotechnical applications. A pressure sensor, a resonant quartz crystal strain gauge with a bourdon tube force collector is the critical sensor of DART.[13] DART detects tsunami waves from the bottom of the open ocean. It has a pressure resolution of approximately 1mm of water when measuring pressure at a depth of several kilometers.[14]
  • Multi-axis force sensors could have plenty of advantages over strain gauges regarding their safety, dexterity, and collaborative perspectives. They are based on pre-stress resonant composite plates of which the measurements are performed by piezoelectric transducers. It allows for measuring 3 components of external forces. Moreover, the hardware needed is cheaper than classical strain gauges.[15]

Non-contact strain measurements edit

Strain can also be measured using digital image correlation (DIC). With this technique one or two cameras are used in conjunction with a DIC software to track features on the surface of components to detect small motion. The full strain map of the tested sample can be calculated, providing similar display as a finite-element analysis. This technique is used in many industries to replace traditional strain gauges or other sensors like extensometers, string pots, LVDT, accelerometers.[16].. The accuracy of commercially available DIC software typically ranges around 1/100 to 1/30 of a pixels for displacements measurements which result in strain sensitivity between 20 and 100 μm/m.[17] The DIC technique allows to quickly measure shape, displacements and strain non-contact, avoiding some issues of traditional contacting methods, especially with impacts, high strain, high-temperature or high cycle fatigue testing.[18]

Industry edit

Nowadays there are many producers in the field of strain measuring. They produce strain gauges for diverse mounting surfaces, sizes, and shapes. For untrained personnel, the correct implementation and the choice of the appropriate type of measurement tool are very difficult. One needs the knowledge of the exact setup process of strain gauges to ensure the collection of usable data. The large providers of strain gauges provide consultation on the correct choice for each application. They also have training programs for their customers to ensure correct implementation.

One of the leading companies is Zemic Europe, offering thousands of different types of strain gauges.[19]

Another global firm is HBM (Hottinger Baldwin Messtechnik GmbH). They offer a wide variety of strain gauges and associated products.[20]

Literature edit

In 1995  Prof. Dr.-Ing. Stefan Keil published the first edition of a detailed book about strain gauges and how to use them called “Dehnungsmessstreifen”. Although this first edition was only published in German, it became popular outside of Germany because of the wide range of uses of strain gauges in different fields. After more than 20 years (in 2017), he published a second edition that was translated into English, hence available to more engineers that use strain gauges. This newest book is titled “Technology and Practical Use of Strain Gages”.[2]

Strain gauge theory (sociology) edit

The term “strain gauge” can be encountered in sociology. The social strain gauge theory is an approach to understanding accusations of witchcraft and sorcery. An anthropologist by the name of Marwick studied these sociological phenomenons in Zambia and Malawi in 1965.[21] Accusations of witchcraft reflect strain on relationships and or the whole social structure. The theory says that the sorcery accusations were a pressure valve of society.[22]

See also edit

References edit

  1. ^ Strain Gage: Materials
  2. ^ a b c Keil, Stephan (2017). Technology and Practical Use of Strain Gages With Particular Consideration of Stress Analysis Using Strain Gages. John Wiley & Sons, Ltd. ISBN 978-3-433-60666-7.
  3. ^ Strain Gage: Sensitivity
  4. ^ Constantan Alloy: Strain Gauge Selection
  5. ^ Shull, Larry C., "Basic Circuits", Hannah, R.L. and Reed, S.E. (Eds.) (1992).Strain Gage Users' Manual, p. 122. Society for Experimental Mechanics. ISBN 0-912053-36-4.
  6. ^ Spark, N. (2006). A History of Murphy's Law. Periscope Film. ISBN 978-0-9786388-9-4
  7. ^ The Strain Gage
  8. ^ Lizotte, Andrew M.; Lokos, William A. (2005-01-01). "Deflection-Based Aircraft Structural Loads Estimation with Comparison to Flight". {{cite journal}}: Cite journal requires |journal= (help)
  9. ^ Ream, W. K.; Hopkins, C. (1991-01-01). "Strain gauges as intrusion detection sensors". Nuclear Materials Management. Annual Meeting Proceedings; (United States). 20. ISSN 0362-0034. OSTI 5494316.
  10. ^ Fountain, Henry (2010-02-08). "America's Cup Rivals Race with the Wind at Their Wings". The New York Times.
  11. ^ Bryzek, J.; Roundy, S.; Bircumshaw, B.; Chung, C.; Castellino, K.; Stetter, J.R.; Vestel, M. (10 April 2006). "Marvelous MEMS". IEEE Circuits and Devices Magazine. 22 (2): 8–28. doi:10.1109/MCD.2006.1615241. S2CID 43985063.
  12. ^ Westerveld, W.J.; Leinders, S.M.; Muilwijk, P.M.; Pozo, J.; van den Dool, T.C.; Verweij, M.D.; Yousefi, M.; Urbach, H.P. (10 January 2014). "Characterization of Integrated Optical Strain Sensors Based on Silicon Waveguides". IEEE Journal of Selected Topics in Quantum Electronics. 20 (4): 101–110. Bibcode:2014IJSTQ..20..101W. doi:10.1109/JSTQE.2013.2289992.
  13. ^ Milburn, Hugh. "The NOAA DART II Description and Disclosure" (PDF). noaa.gov. NOAA, U.S. Government. Retrieved 4 April 2020.
  14. ^ Eble, M. C.; Gonzalez, F. I. "Deep-Ocean Bottom Pressure Measurements in the Northeast Pacific" (PDF). noaa.gov. NOAA, U.S. Government. Retrieved 4 April 2020.
  15. ^ Castaño-cano, Davinson; Grossard, Mathieu; Hubert, Arnaud (July 2014). "Multi-axis force sensing with pre-stressed resonant composite plates: An alternative to strain gauge force sensors". 2014 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (PDF). pp. 1361–1367. doi:10.1109/AIM.2014.6878272. ISBN 978-1-4799-5736-1. S2CID 15977483.
  16. ^ Carr, Jennifer; Baqersad, Javad; Niezrecki, Christopher; Avitabile, Peter; Slattery, Micheal (2012), "Dynamic Stress–Strain on Turbine Blades Using Digital Image Correlation Techniques Part 2: Dynamic Measurements", Topics in Experimental Dynamics Substructuring and Wind Turbine Dynamics, Volume 2, Springer New York, pp. 221–226, doi:10.1007/978-1-4614-2422-2_21, ISBN 9781461424215
  17. ^ Carr, Jennifer; Baqersad, Javad; Niezrecki, Christopher; Avitabile, Peter; Slattery, Micheal (2012), "Dynamic Stress–Strain on Turbine Blade Using Digital Image Correlation Techniques Part 1: Static Load and Calibration", Topics in Experimental Dynamics Substructuring and Wind Turbine Dynamics, Volume 2, Springer New York, pp. 215–220, doi:10.1007/978-1-4614-2422-2_20, ISBN 9781461424215
  18. ^ Littell, Justin D. (2011), "Large Field Photogrammetry Techniques in Aircraft and Spacecraft Impact Testing", Dynamic Behavior of Materials, Volume 1, Conference Proceedings of the Society for Experimental Mechanics Series, Springer New York, pp. 55–67, doi:10.1007/978-1-4419-8228-5_9, hdl:2060/20100024230, ISBN 9781441982278
  19. ^ "Dehnungsmesstreifen". Zemic Europe (in German). Retrieved 2022-05-10.
  20. ^ "Grundlagen der Dehnungsmessstreifen". HBM (in German). 2019-10-29. Retrieved 2022-05-10.
  21. ^ Bernard, Spencer (2002). Encyclopedia of Social and Cultural Anthropology. Routeledge. p. 563. ISBN 0-415-28558-5.
  22. ^ "The Motivations and Social Impacts of Accusations of Sorcery" (PDF). Ewer. 5 March 2014.

strain, gauge, strain, gauge, also, spelled, strain, gage, device, used, measure, strain, object, invented, edward, simmons, arthur, ruge, 1938, most, common, type, strain, gauge, consists, insulating, flexible, backing, which, supports, metallic, foil, patter. A strain gauge also spelled strain gage is a device used to measure strain on an object Invented by Edward E Simmons and Arthur C Ruge in 1938 the most common type of strain gauge consists of an insulating flexible backing which supports a metallic foil pattern The gauge is attached to the object by a suitable adhesive such as cyanoacrylate 1 As the object is deformed the foil is deformed causing its electrical resistance to change This resistance change usually measured using a Wheatstone bridge is related to the strain by the quantity known as the gauge factor Typical foil strain gauge the blue region is conductive and resistance is measured from one large blue pad to the other The gauge is far more sensitive to strain in the vertical direction than in the horizontal direction The markings outside the active area help to align the gauge during installation Contents 1 History 2 Physical operation 3 Gauge factor 4 In practice 4 1 Variations in temperature 5 Applications 5 1 Structural health monitoring 5 2 Biological measurements 5 3 Predictive maintenance 5 4 Aviation 5 5 Repurposing 6 Errors and compensations 7 Geometries of strain gauges 8 Other types 9 Non contact strain measurements 10 Industry 11 Literature 12 Strain gauge theory sociology 13 See also 14 ReferencesHistory editEdward E Simmons and Professor Arthur C Ruge independently invented the strain gauge Simmons was involved in a research project by Datwyler and Clark at Caltech between 1936 and 1938 They researched the stress strain behavior of metals under shock loads Simmons came up with an original way to measure the force introduced into the sample by equipping a dynamometer with fine resistance wires Arthur C Ruge a professor at MIT on the other hand conducted research in seismology He tried to analyze the behavior of a model water tank installed on a vibration table He was not able to utilize the standard optical strain measurement methods of his time due to the small scale and low strains in his model Professor Ruge and his assistant J Hanns Meier had the epiphany of measuring the resistance change caused by strain in metallic wires cemented on the thin walls of the water tank model The development of the strain gauge was essentially just a byproduct of other research projects Edward E Simmons and Professor Arthur C Ruge developed a widely used and useful measurement tool due to the lack of an alternative at their times Arthur C Ruge realized the commercial utility of the strain gauge His employer at MIT waived all claims on the right of the invention as they did not predict the economic and large scale usage potential This prediction turned out to be false The strain gauge applications were quickly gaining traction as they served to indirectly detect all other quantities that induce strain Additionally they were simple to install by the scientists did not cause any obstruction or property changes to the observed object and thus falsifying the measurement results Probably the last and most important property was the ease of transmission of the electrical output signal 2 Physical operation edit nbsp An unmounted resistive foil strain gaugeA strain gauge takes advantage of the physical property of electrical conductance and its dependence on the conductor s geometry When an electrical conductor is stretched within the limits of its elasticity such that it does not break or permanently deform it will become narrower and longer which increases its electrical resistance end to end Conversely when a conductor is compressed such that it does not buckle it will broaden and shorten which decreases its electrical resistance end to end From the measured electrical resistance of the strain gauge the amount of induced stress may be inferred A typical strain gauge arranges a long thin conductive strip in a zig zag pattern of parallel lines This does not increase the sensitivity since the percentage change in resistance for a given strain for the entire zig zag is the same as for any single trace A single linear trace would have to be extremely thin hence liable to overheating which would change its resistance and cause it to expand or would need to be operated at a much lower voltage making it difficult to measure resistance changes accurately Gauge factor editThe gauge factor G F displaystyle GF nbsp is defined as G F D R R G ϵ displaystyle GF frac Delta R R G epsilon nbsp where D R displaystyle Delta R nbsp is the change in resistance caused by strain R G displaystyle R G nbsp is the resistance of the undeformed gauge and ϵ displaystyle epsilon nbsp is strain For common metallic foil gauges the gauge factor is usually a little over 2 3 For a single active gauge and three dummy resistors of the same resistance about the active gauge in a balanced Wheatstone bridge configuration the output sensor voltage S V displaystyle SV nbsp from the bridge is approximately S V E V G F ϵ 4 displaystyle SV EV frac GF cdot epsilon 4 nbsp where E V displaystyle EV nbsp is the bridge excitation voltage Foil gauges typically have active areas of about 2 10 mm2 in size With careful installation the correct gauge and the correct adhesive strains up to at least 10 can be measured In practice edit nbsp Visualization of the working concept behind the strain gauge on a beam under exaggerated bendingAn excitation voltage is applied to input leads of the gauge network and a voltage reading is taken from the output leads Typical input voltages are 5 V or 12 V and typical output readings are in millivolts Foil strain gauges are used in many situations Different applications place different requirements on the gauge In most cases the orientation of the strain gauge is significant Gauges attached to a load cell would normally be expected to remain stable over a period of years if not decades while those used to measure response in a dynamic experiment may only need to remain attached to the object for a few days be energized for less than an hour and operate for less than a second Strain gauges are attached to the substrate with a special glue The type of glue depends on the required lifetime of the measurement system For short term measurements up to some weeks cyanoacrylate glue is appropriate for long lasting installation epoxy glue is required Usually epoxy glue requires high temperature curing at about 80 100 C The preparation of the surface where the strain gauge is to be glued is of the utmost importance The surface must be smoothed e g with very fine sand paper deoiled with solvents the solvent traces must then be removed and the strain gauge must be glued immediately after this to avoid oxidation or pollution of the prepared area If these steps are not followed the strain gauge binding to the surface may be unreliable and unpredictable measurement errors may be generated Strain gauge based technology is used commonly in the manufacture of pressure sensors The gauges used in pressure sensors themselves are commonly made from silicon polysilicon metal film thick film and bonded foil Variations in temperature edit Variations in temperature will cause a multitude of effects The object will change in size by thermal expansion which will be detected as a strain by the gauge Resistance of the gauge will change and resistance of the connecting wires will change Most strain gauges are made from a constantan alloy 4 Various constantan alloys and Karma alloys have been designed so that the temperature effects on the resistance of the strain gauge itself largely cancel out the resistance change of the gauge due to the thermal expansion of the object under test Because different materials have different amounts of thermal expansion self temperature compensation STC requires selecting a particular alloy matched to the material of the object under test Strain gauges that are not self temperature compensated such as isoelastic alloy can be temperature compensated by use of the dummy gauge technique A dummy gauge identical to the active strain gauge is installed on an unstrained sample of the same material as the test specimen The sample with the dummy gauge is placed in thermal contact with the test specimen adjacent to the active gauge The dummy gauge is wired into a Wheatstone bridge on an adjacent arm to the active gauge so that the temperature effects on the active and dummy gauges cancel each other 5 Murphy s law was originally coined in response to a set of gauges being incorrectly wired into a Wheatstone bridge 6 Every material reacts when it heats up or when it cools down This will cause strain gauges to register a deformation in the material which will make it change signal To prevent this from happening strain gauges are made so they will compensate this change due to temperature Dependent on the material of the surface where the strain gauge is assembled on a different expansion can be measured Temperature effects on the lead wires can be cancelled by using a 3 wire bridge or a 4 wire ohm circuit 7 also called a 4 wire Kelvin connection In any case it is a good engineering practice to keep the Wheatstone bridge voltage drive low enough to avoid the self heating of the strain gauge The self heating of the strain gauge depends on its mechanical characteristic large strain gauges are less prone to self heating Low voltage drive levels of the bridge reduce the sensitivity of the overall system Applications editStructural health monitoring edit Structural health monitoring SHM is used to monitor structures after their completion To prevent failures strain gauges are used to detect and locate damages and creep A specific example is the monitoring of bridge cables increasing safety by detecting possible damages Also the bridge s behavior to unusual loads can be analyzed such as special heavy duty transports Biological measurements edit Measuring the strain of skin can provide a multitude of biomechanic measurements such as posture joint rotation respiration and swelling both in humans and other animals Resistive foil strain gauges are seldom used for these applications however due to their low strain limit Instead soft and deformable strain gauges are often attached to a host garment to make it simple to apply the sensor to the correct part of the body though sometimes they are attached directly to the skin Typically in these applications such soft strain gauges 1 are known as stretch sensors For medical use the sensors must be accurate and repeatable which typically requires the use of capacitive stretch sensors Predictive maintenance edit Many objects and materials in industrial applications have a finite life To improve their lifetime and cost of ownership predictive maintenance principles are used Strain gauges can be used to monitor the strain as an indicator of fatigue in materials to enable software systems to predict when certain components need to be replaced or serviced Resistive foil gauges can be used to instrument stiff materials like metals ceramics composites and similar whereas highly elastic strain gauges are used to monitor softer materials such as rubber plastics textiles and the like 2 Aviation edit In aviation strain gauges are the standard approach to measuring the structural load and calculating wing deflection Strain gauges are fixed in several locations on the aircraft However deflection measurement systems have been shown to measure reliable strains remotely This reduces instrumentation weight on the aircraft and thus is replacing the strain gauge 8 Repurposing edit There are also applications where it isn t first obvious that you would measure strain to get to the wanted result So for example in the detection of intruders on certain structures strain gauges can be used to detect the presence of such an intruder This is done by measuring the slight change in strain of the said structure 9 Errors and compensations editZero Offset If the impedance of the four gauge arms are not exactly the same after bonding the gauge to the force collector there will be a zero offset which can be compensated by introducing a parallel resistor to one or more of the gauge arms Temperature coefficient of gauge factor TCGF is the change of sensitivity of the device to strain with change in temperature This is generally compensated for by the introduction of a fixed resistance in the input leg whereby the effective supplied voltage will decrease with a temperature increase compensating for the increase in sensitivity with the temperature increase This is known as modulus compensation in transducer circuits As the temperature rises the load cell element becomes more elastic and therefore under a constant load will deform more and lead to an increase in output but the load is still the same The clever bit in all this is that the resistor in the bridge supply must be a temperature sensitive resistor that is matched to both the material to which the gauge is bonded and also to the gauge element material The value of that resistor is dependent on both of those values and can be calculated In simple terms if the output increases then the resistor value also increase thereby reducing the net voltage to the transducer Get the resistor value right and you will see no change Zero shift with temperature If the TCGF of each gauge is not the same there will be a zero shift with temperature This is also caused by anomalies in the force collector This is usually compensated for with one or more resistors strategically placed in the compensation network Linearity is an error whereby the sensitivity changes across the pressure range This is commonly a function of the force collection thickness selection for the intended pressure and the quality of the bonding Hysteresis is an error of return to zero after pressure excursion Repeatability This error is sometimes tied in with hysteresis but is across the pressure range Electromagnetic interference EMI induced errors As the output voltage of strain gauges is in the mV range even mV if the Wheatstone bridge voltage drive is kept low to avoid self heating of the element special care must be taken in output signal amplification to avoid amplifying also the superimposed noise A solution which is frequently adopted is to use carrier frequency amplifiers which convert the voltage variation into a frequency variation as in voltage controlled oscillators and have a narrow bandwidth thus reducing out of band EMI Overloading If a strain gauge is loaded beyond its design limit measured in microstrain its performance degrades and can not be recovered Normally good engineering practice suggests not to stress strain gauges beyond 3000 microstrain Humidity If the wires connecting the strain gauge to the signal conditioner are not protected against humidity such as bare wire corrosion can occur leading to parasitic resistance This can allow currents to flow between the wires and the substrate to which the strain gauge is glued or between the two wires directly introducing an error which competes with the current flowing through the strain gauge For this reason high current low resistance strain gauges 120 ohm are less prone to this type of error To avoid this error it is sufficient to protect the strain gauges wires with insulating enamel e g epoxy or polyurethane type Strain gauges with unprotected wires may be used only in a dry laboratory environment but not in an industrial one In some applications strain gauges add mass and damping to the vibration profiles of the hardware they are intended to measure In the turbomachinery industry one used alternative to strain gauge technology in the measurement of vibrations on rotating hardware is the non intrusive stress measurement system which allows measurement of blade vibrations without any blade or disc mounted hardware Geometries of strain gauges edit nbsp Geometries of strain gaugesThe following different kind of strain gauges are available in the market Linear strain gauges Membrane Rosette strain gauges Double linear strain gauges Full bridge strain gauges Shear strain gauges Half bridge strain gauges Column strain gauges 45 Rosette 3 measuring directions 90 Rosette 2 measuring directions Other types editStrain Gauge measurement devices are prone to drift problems Additionally their manufacturing requires precise requirements during all the production steps So there are multiple different ways of also measuring strain 2 For measurements of small strain semiconductor strain gauges so called piezoresistors are often preferred over foil gauges A semiconductor gauge usually has a larger gauge factor than a foil gauge Semiconductor gauges tend to be more expensive more sensitive to temperature changes and are more fragile than foil gauges Nanoparticle based strain gauges emerge as a new promising technology These resistive sensors whose active area is made by an assembly of conductive nanoparticles such as gold or carbon combine a high gauge factor a large deformation range and a small electrical consumption due to their high impedance In biological measurements especially blood flow and tissue swelling a variant called mercury in rubber strain gauge is used This kind of strain gauge consists of a small amount of liquid mercury enclosed in a small rubber tube which is applied around e g a toe or leg Swelling of the body part results in stretching of the tube making it both longer and thinner which increases electrical resistance Fiber optic sensing can be employed to measure strain along an optical fiber Measurements can be distributed along the fiber or taken at predetermined points on the fiber The 2010 America s Cup boats Alinghi 5 and USA 17 both employ embedded sensors of this type 10 nbsp Example of non contact strain measurement using digital image correlation on a material testing coupon showing moving strain structures called Luders bandsOther optical measuring techniques can be used to measure strains like electronic speckle pattern interferometry or digital image correlation Microscale strain gauges are widely used in microelectromechanical systems MEMS to measure strains such as those induced by force acceleration pressure or sound 11 As example airbags in cars are often triggered with MEMS accelerometers As alternative to piezo resistant strain gauges integrated optical ring resonators may be used to measure strain in microoptoelectromechanical systems MOEMS 12 Capacitive strain gauges use a variable capacitor to indicate the level of mechanical deformation Vibrating wire strain gauges are used in geotechnical and civil engineering applications The gauge consists of a vibrating tensioned wire The strain is calculated by measuring the resonant frequency of the wire an increase in tension increases the resonant frequency Quartz crystal strain gauges are also used in geotechnical applications A pressure sensor a resonant quartz crystal strain gauge with a bourdon tube force collector is the critical sensor of DART 13 DART detects tsunami waves from the bottom of the open ocean It has a pressure resolution of approximately 1mm of water when measuring pressure at a depth of several kilometers 14 Multi axis force sensors could have plenty of advantages over strain gauges regarding their safety dexterity and collaborative perspectives They are based on pre stress resonant composite plates of which the measurements are performed by piezoelectric transducers It allows for measuring 3 components of external forces Moreover the hardware needed is cheaper than classical strain gauges 15 Non contact strain measurements editStrain can also be measured using digital image correlation DIC With this technique one or two cameras are used in conjunction with a DIC software to track features on the surface of components to detect small motion The full strain map of the tested sample can be calculated providing similar display as a finite element analysis This technique is used in many industries to replace traditional strain gauges or other sensors like extensometers string pots LVDT accelerometers 16 The accuracy of commercially available DIC software typically ranges around 1 100 to 1 30 of a pixels for displacements measurements which result in strain sensitivity between 20 and 100 mm m 17 The DIC technique allows to quickly measure shape displacements and strain non contact avoiding some issues of traditional contacting methods especially with impacts high strain high temperature or high cycle fatigue testing 18 Industry editNowadays there are many producers in the field of strain measuring They produce strain gauges for diverse mounting surfaces sizes and shapes For untrained personnel the correct implementation and the choice of the appropriate type of measurement tool are very difficult One needs the knowledge of the exact setup process of strain gauges to ensure the collection of usable data The large providers of strain gauges provide consultation on the correct choice for each application They also have training programs for their customers to ensure correct implementation One of the leading companies is Zemic Europe offering thousands of different types of strain gauges 19 Another global firm is HBM Hottinger Baldwin Messtechnik GmbH They offer a wide variety of strain gauges and associated products 20 Literature editIn 1995 Prof Dr Ing Stefan Keil published the first edition of a detailed book about strain gauges and how to use them called Dehnungsmessstreifen Although this first edition was only published in German it became popular outside of Germany because of the wide range of uses of strain gauges in different fields After more than 20 years in 2017 he published a second edition that was translated into English hence available to more engineers that use strain gauges This newest book is titled Technology and Practical Use of Strain Gages 2 Strain gauge theory sociology editThe term strain gauge can be encountered in sociology The social strain gauge theory is an approach to understanding accusations of witchcraft and sorcery An anthropologist by the name of Marwick studied these sociological phenomenons in Zambia and Malawi in 1965 21 Accusations of witchcraft reflect strain on relationships and or the whole social structure The theory says that the sorcery accusations were a pressure valve of society 22 See also editResistance thermometer CompressometerReferences edit Strain Gage Materials a b c Keil Stephan 2017 Technology and Practical Use of Strain Gages With Particular Consideration of Stress Analysis Using Strain Gages John Wiley amp Sons Ltd ISBN 978 3 433 60666 7 Strain Gage Sensitivity Constantan Alloy Strain Gauge Selection Shull Larry C Basic Circuits Hannah R L and Reed S E Eds 1992 Strain Gage Users Manual p 122 Society for Experimental Mechanics ISBN 0 912053 36 4 Spark N 2006 A History of Murphy s Law Periscope Film ISBN 978 0 9786388 9 4 The Strain Gage Lizotte Andrew M Lokos William A 2005 01 01 Deflection Based Aircraft Structural Loads Estimation with Comparison to Flight a href Template Cite journal html title Template Cite journal cite journal a Cite journal requires journal help Ream W K Hopkins C 1991 01 01 Strain gauges as intrusion detection sensors Nuclear Materials Management Annual Meeting Proceedings United States 20 ISSN 0362 0034 OSTI 5494316 Fountain Henry 2010 02 08 America s Cup Rivals Race with the Wind at Their Wings The New York Times Bryzek J Roundy S Bircumshaw B Chung C Castellino K Stetter J R Vestel M 10 April 2006 Marvelous MEMS IEEE Circuits and Devices Magazine 22 2 8 28 doi 10 1109 MCD 2006 1615241 S2CID 43985063 Westerveld W J Leinders S M Muilwijk P M Pozo J van den Dool T C Verweij M D Yousefi M Urbach H P 10 January 2014 Characterization of Integrated Optical Strain Sensors Based on Silicon Waveguides IEEE Journal of Selected Topics in Quantum Electronics 20 4 101 110 Bibcode 2014IJSTQ 20 101W doi 10 1109 JSTQE 2013 2289992 Milburn Hugh The NOAA DART II Description and Disclosure PDF noaa gov NOAA U S Government Retrieved 4 April 2020 Eble M C Gonzalez F I Deep Ocean Bottom Pressure Measurements in the Northeast Pacific PDF noaa gov NOAA U S Government Retrieved 4 April 2020 Castano cano Davinson Grossard Mathieu Hubert Arnaud July 2014 Multi axis force sensing with pre stressed resonant composite plates An alternative to strain gauge force sensors 2014 IEEE ASME International Conference on Advanced Intelligent Mechatronics PDF pp 1361 1367 doi 10 1109 AIM 2014 6878272 ISBN 978 1 4799 5736 1 S2CID 15977483 Carr Jennifer Baqersad Javad Niezrecki Christopher Avitabile Peter Slattery Micheal 2012 Dynamic Stress Strain on Turbine Blades Using Digital Image Correlation Techniques Part 2 Dynamic Measurements Topics in Experimental Dynamics Substructuring and Wind Turbine Dynamics Volume 2 Springer New York pp 221 226 doi 10 1007 978 1 4614 2422 2 21 ISBN 9781461424215 Carr Jennifer Baqersad Javad Niezrecki Christopher Avitabile Peter Slattery Micheal 2012 Dynamic Stress Strain on Turbine Blade Using Digital Image Correlation Techniques Part 1 Static Load and Calibration Topics in Experimental Dynamics Substructuring and Wind Turbine Dynamics Volume 2 Springer New York pp 215 220 doi 10 1007 978 1 4614 2422 2 20 ISBN 9781461424215 Littell Justin D 2011 Large Field Photogrammetry Techniques in Aircraft and Spacecraft Impact Testing Dynamic Behavior of Materials Volume 1 Conference Proceedings of the Society for Experimental Mechanics Series Springer New York pp 55 67 doi 10 1007 978 1 4419 8228 5 9 hdl 2060 20100024230 ISBN 9781441982278 Dehnungsmesstreifen Zemic Europe in German Retrieved 2022 05 10 Grundlagen der Dehnungsmessstreifen HBM in German 2019 10 29 Retrieved 2022 05 10 Bernard Spencer 2002 Encyclopedia of Social and Cultural Anthropology Routeledge p 563 ISBN 0 415 28558 5 The Motivations and Social Impacts of Accusations of Sorcery PDF Ewer 5 March 2014 Retrieved from https en wikipedia org w index php title Strain gauge amp oldid 1190173592, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.