Sound Transmission Class (or STC) is an integer rating of how well a building partition attenuates airborne sound. In the US, it is widely used to rate interior partitions, ceilings, floors, doors, windows and exterior wall configurations. Outside the US, the ISO Sound Reduction Index (SRI) is used. The STC rating very roughly reflects the decibel reduction of noise that a partition can provide. The STC is useful for evaluating annoyance due to speech sounds, but not music or machinery noise as these sources contain more low frequency energy than speech.[1]

There are many ways to improve the sound transmission class of a partition, though the two most basic principles are adding mass and increasing the overall thickness. In general, the sound transmission class of a double wythe wall (e.g. two 4"-thick block walls separated by a 2" airspace) is greater than a single wall of equivalent mass (e.g. homogeneous 8" block wall).[2]

Definition edit

The STC or sound transmission class is a single number method of rating how well wall partitions reduce sound transmission.[3] The STC provides a standardized way to compare products such as doors and windows made by competing manufacturers. A higher number indicates more effective sound insulation than a lower number. The STC is a standardized rating provided by ASTM E413 based on laboratory measurements performed in accordance with ASRM E90. ASTM E413 can also be used to determine similar ratings from field measurements performed in accordance with ASTM E336.[3]

Sound Isolation and Sound Insulation are used interchangeably, though the term "Insulation" is preferred outside the US.[4] The term "sound proofing" is typically avoided in architectural acoustics as it is a misnomer and connotes inaudibility.

Subjective correlation edit

Through research, acousticians have developed tables that pair a given STC rating with a subjective experience. The table below is used to determine the degree of sound isolation provided by typical multi-family construction. Generally, a difference of one or two STC points between similar constructions is subjectively insignificant.[5]

STCs by audio distinguishability
STC What can be heard
25 Normal speech can be understood
30 Loud speech can be understood
35 Loud speech audible but not intelligible
40 Loud speech audible as a murmur
45 Loud speech heard but not audible
50 Loud sounds faintly heard
60+ Good soundproofing; most sounds do not disturb neighboring residents.[6]

Tables like the one above are highly dependent on the background noise levels in the receiving room: the louder the background noise, the greater the perceived sound isolation.[7]

Rating methodology edit

Historical edit

Prior to the STC rating, the sound isolation performance of a partition was measured and reported as the average transmission loss of over the frequency range 128 to 4096 Hz or 256 to 1021 Hz.[8][9] This method is valuable at comparing homogeneous partitions that follow the mass law, but can be misleading when comparing complex or multi-leaf walls.

In 1961, the ASTM International Standards Organization adopted E90-61T, which served as the basis for the STC method used today. The STC standard curve is based on European studies of multi-family residential construction, and closely resembles the sound isolation performance of a 9"-thick brick wall.[10]

Current edit

 
Sound Transmission Class Report Sample from NTi Audio showing Transmission Loss in the sixteen standard frequencies

The STC number is derived from sound attenuation values tested at sixteen standard frequencies from 125 Hz to 4000 Hz. These Transmission Loss values are then plotted on a sound pressure level graph and the resulting curve is compared to a standard reference contour provided by the ASTM.[11]

Sound isolation metrics, such as the STC, are measured in specially-isolated and designed laboratory test chambers. There are nearly infinite field conditions that will affect sound isolation on site when designing building partitions and enclosures.

Factors affecting sound transmission class edit

Acoustic medium edit

Sound travels through both the air and structure, and both paths must be considered when designing sound isolating walls and ceilings. To eliminate air borne sound all air paths between the areas must be eliminated. This is achieved by making seams airtight and closing all sound leaks. To eliminate structure-borne noise one must create isolation systems that reduce mechanical connections between those structures.[12]

Mass edit

Adding mass to a partition reduces the transmission of sound. This is often achieved by adding additional layers of gypsum. It is preferable to have non symmetrical leaves, for example with different thickness gypsum.[13] The effect of adding multiple layers of gypsum wallboard to a frame also varies depending on the framing type and configuration.[14][15] Doubling the mass of a partition does not double the STC, as the STC is calculated from a non-linear decibel sound transmission loss measurement.[16] So, whereas installing an additional layer of gypsum wallboard to a light-gauge (25-ga. or lighter) steel stud partition will result in about a 5 STC-point increase, doing the same on single wood or single heavy-gauge steel will result in only 2 to 3 additional STC points.[14][15] Adding a second additional layer (to the already 3-layer system) does not result in as drastic an STC change as the first additional layer.[14] The effect of additional gypsum wallboard layers on double- and staggered-stud partitions is similar to that of light-gauge steel partitions.

Due to increased mass, poured concrete and concrete blocks typically achieve higher STC values (in the mid STC 40s to the mid STC 50s) than equally thick framed walls.[17] However the additional weight, added complexity of construction, and poor thermal insulation tend to limit masonry wall partitions as a viable sound isolation solution in many building construction projects.

In recent years, gypsum board manufacturers have started to offer lightweight drywall board: Normal weight gypsum has a nominal density of 43pcf and lightweight drywall has a nominal density of 36pcf. This does not have a large effect on the STC rating, though lightweight gypsum can significantly degrade the low frequency performance of a partition as compared to normal weight gypsum.

Sound absorption edit

Sound absorption entails turning acoustical energy into some other form of energy, usually heat.[18]

Adding absorptive materials to the interior surfaces of rooms, for example fabric-faced fiberglass panels and thick curtains, will result in a decrease of reverberated sound energy within the room. However, absorptive interior surface treatments of this kind do not significantly improve the sound transmission class.[19] Installing absorptive insulation, for example fiberglass batts and blow-in cellulose, into the wall or ceiling cavities does increase the sound transmission class significantly.[14] The presence of insulation in single 2x4 wood stud framing spaced 16" (406 mm) on-center results in only a few STC points. This is because a wall with 2x4 wood stud framing spaced 16" develops significant resonances which are not mitigated by the cavity insulation. In contrast, adding standard fiberglass insulation to an otherwise empty cavity in light-gauge (25-gauge or lighter) steel stud partitions can result in a nearly 10 STC-point improvement.

Other studies have shown that fibrous insulation materials, such as mineral wool, can increase the STC by 5 to 8 points.[13]

Stiffness edit

The effect of stiffness on sound isolation can relate to either the material stiffness of the sound isolating material or the stiffness caused by framing methods.

Framing methods edit

Structurally decoupling the gypsum wallboard panels from the partition framing can result in a large increase in sound isolation when installed correctly. Examples of structural decoupling in building construction include resilient channels, sound isolation clips and hat channels, and staggered- or double-stud framing. The STC results of decoupling in wall and ceiling assemblies varies significantly depending on the framing type, air cavity volume, and decoupling material type.[14] Great care must be taken in each type of decoupled partition construction, as any fastener that becomes mechanically (rigidly) coupled to the framing can undermine the decoupling and result in drastically lower sound isolation results.[20]

When two leaves are rigidly tied or coupled by a stud, the sound isolation of the system depends on the stiffness of the stud. Light-gauge (25-gauge or lighter) provides better sound isolation than 16-20-gauge steel, and noticeably better performance than wood studs.[21] When heavy gauge steel or wood studs are spaced 16" on center, additional resonances form which further lower the sound isolation performance of a partition. For typical gypsum stud walls, this resonance occurs in the 100–160 Hz region and is thought to be a hybrid of the mass-air-mass resonance and a bending mode resonance caused when a plate is closely supported by stiff members.[22]

Single metal stud partitions are more effective than single wood stud partitions, and have been shown to increase the STC rating by up to 10 points. However, there is little difference between metal and wood studs when used in double stud partitions.[13] Double stud partitions have a higher STC than single stud.[13]

In certain assemblies, increasing the stud spacing from 16 to 24 inches increases the STC rating by 2 to 3 points.[13]

Damping edit

Though the terms sound absorption and damping are often interchangeable when discussing room acoustics, acousticians define these as two distinct properties of sound-isolating walls.

Several gypsum manufacturers offer specialty products which use constrained layer damping, which is a form of viscous damping.[23][24] Damping generally increases the sound isolation of partitions, particularly at mid-and-high frequencies.

Damping is also used to improve the sound isolation performance of glazing assemblies. Laminated glazing, which consists of a Polyvinyl butyral (or PVB) inter-layer, performs better acoustically than a non-laminated glass of equivalent thickness.[25]

Sound leakage edit

 
A small gap in the wall can greatly reduce the STC rating. This wall did not receive a full perimeter seal.

All holes and gaps should be filled and the enclosure hermetically sealed for sound isolation to be effective. The table below illustrates sound proofing test results from a wall partition that has a theoretical maximum loss of 40 dB from one room to the next and a partition area of 10 meters squared. Even small open gaps and holes in the partition have a disproportionate reduction in sound proofing. A 5% opening in the partition, which offers unrestricted sound transmission from one room to the next, caused the transmission loss to reduce from 40 dB to 13 dB. A 0.1% open area will reduce the transmission loss from 40 dB to 30 dB, which is typical of walls where caulking has not been applied effectively[26] Partitions that are inadequately sealed and contain back-to-back electrical boxes, untreated recessed lighting and unsealed pipes offer flanking paths for sound and significant leakage.[27]

Acoustic joint tapes and caulking have been used to improve sound isolation since the early 1930s.[28] Although the applications of tapes was largely limited to defense and industrial applications such as naval vessels and aircraft in the past, recent research has proven the effectiveness of sealing gaps and thereby improving the sound isolation performance of a partition.[29]

Sound diminution by percentage openness of barrier
Transmission loss % of area open
13 dB 5% open
17 dB 2% open
20 dB 1% open
23 dB 0.5% open
27 dB 0.2% open
30 dB 0.1% open
33 dB 0.05% open
37 dB 0.02% open
39.5 dB Practical maximum loss
40 dB Theoretical maximum loss

Flanking edit

Building codes typically allow for a 5-point tolerance between the lab-tested and field-measured STC rating; however, studies have shown that even in well-built and sealed installations the difference between the lab and field rating is highly dependent on the type of assembly.[30]

Special variations of STC edit

By nature, the STC rating is derived from lab testing under ideal conditions. There are other versions of the STC rating to account for real-world conditions.

Composite STC edit

The net sound isolation performance of a partition containing multiple sound isolating elements such as doors, windows, etc.

Apparent Sound Transmission Class (ASTC) edit

The sound isolation performance of a partition measured in the field according to ASTM E336, normalized to account for different room finishes and the area of the tested partition (i.e. compare the same wall measured in a bare living room and an acoustically dry recording booth).

Normalized Noise Isolation Class (NNIC) edit

The sound isolation performance of a partition measured in the field according to ASTM E336, normalized to account for the reverberation time in the room.

Noise Isolation Class (NIC) edit

The sound isolation performance of a partition measured in the field according to ASTM E336, not normalized to the room conditions of the test.

Field Sound Transmission Class (FSTC) edit

The sound isolation performance of a specific elements in a partition, as measured in the field and achieved by suppressing the effects of sound flanking paths. This can be useful for measuring walls with doors, when you are interested in removing the influence of the door on the measured field STC. The FSTC testing method was historically prescribed by ASTM E336, however the latest version of this standard does not include FSTC.[31]

Door Sound Transmission Class (DTC) edit

The sound isolation performance of doors when measured according to ASTM E2964.[32]

Legal and practical requirements edit

Section 1206 of International Building Code 2021 states that separation between dwelling units and public and service areas must achieve STC 50 where tested in accordance with ASTM E90, or NNIC 45 if field tested in accordance with ASTM E336. However, not all jurisdictions use the IBC for their building or municipal code.

Common partition STC edit

Interior walls with 1 sheet of 1/2" (13 mm) gypsum wallboard (drywall) on either side of 2x4 (90 mm) wood studs spaced 16" (406 mm) on-center with no fiberglass insulation filling each stud cavity have an STC of about 33.[14] When asked to rate their acoustical performance, people often describe these walls as "paper thin." They offer little in the way of privacy. Double stud partition walls are typically constructed with varying gypsum wallboard panel layers attached to both sides of double 2x4 (90 mm) wood studs spaced 16" (406 mm) on-center and separated by a 1" (25 mm) airspace. These walls vary in sound isolation performance from the mid STC-40s into the high STC-60s depending on the presence of insulation and the gypsum wallboard type and quantity.[14] Commercial buildings are typically constructed using steel studs of varying widths, gauges, and on-center spacings. Each of these framing characteristics have an effect on the sound isolation of the partition to varying degrees.[15]

STCs by partition type
STC Partition type
27 Single pane glass window (typical value) (dual-pane glass window range is 26–32)"STC Ratings".
33 Single layer of 1/2" drywall on each side, wood studs, no insulation (typical interior wall)
39 Single layer of 1/2" drywall on each side, wood studs, fiberglass insulation[33]
44 4" hollow CMU (concrete masonry unit)[34]
45 Double layer of 1/2" drywall on each side, wood studs, batt insulation in wall
46 Single layer of 1/2" drywall, glued to 6" lightweight concrete block wall, painted both sides
46 6" hollow CMU (concrete masonry unit)[34]
48 8" hollow CMU (concrete masonry unit)[34]
50 10" hollow CMU (concrete masonry unit)[34]
52 8" hollow CMU (concrete masonry unit) with 2" Z-bars and 1/2" drywall on each side[35]
54 Single layer of 1/2" drywall, glued to 8" dense concrete block wall, painted both sides
54 8" hollow CMU (concrete masonry unit) with 1 1/2" wood furring, 1 1/2" fiberglass insulation and 1/2" drywall on each side[35]
55 Double layer of 1/2" drywall on each side, on staggered wood stud wall, batt insulation in wall
59 Double layer of 1/2" drywall on each side, on wood stud wall, resilient channels on one side, batt insulation
63 Double layer of 1/2" drywall on each side, on double wood/metal stud walls (spaced 1" apart), double batt insulation
64 8" hollow CMU (concrete masonry unit) with 3" steel studs, fiberglass insulation and 1/2" drywall on each side[35]
72 8" concrete block wall, painted, with 1/2" drywall on independent steel stud walls, each side, insulation in cavities

STC prediction edit

There are several commercially available software which predict the STC ratings of partitions using a combination of theoretical models and empirically derived lab data. These programs can predict STC ratings within several points of a tested partition and are an approximation at best.[36]

Outdoor-Indoor Transmission Class (OITC) edit

The Outdoor–Indoor Transmission Class (OITC) is a standard used for indicating the rate of sound transmission from outdoor noise sources into a building. It is based on the ASTM E-1332 Standard Classification for Rating Outdoor-Indoor Sound Attenuation.[37] Unlike the STC, which is based on a noise spectrum targeting speech sounds, OITC uses a source noise spectrum that considers frequencies down to 80 Hz (aircraft/rail/truck traffic) and is weighted more to lower frequencies. The OITC value is typically used to rate, evaluate, and select exterior glazing assemblies.

See also edit

References edit

  1. ^ Roller, H. Stanley (November 1985). "Isolating music and mechanical equipment sound sources with gypsum board partition systems". The Journal of the Acoustical Society of America. 78 (S1): S10. Bibcode:1985ASAJ...78...10R. doi:10.1121/1.2022641. ISSN 0001-4966.
  2. ^ Egan, M. David. (2007). Architectural acoustics. J. Ross Publishing. ISBN 978-1-932159-78-3. OCLC 636858059.
  3. ^ a b Ballou 2008, p. 72.
  4. ^ Hopkins, Carl. (2016). Sound insulation. Routledge. ISBN 978-1-138-13770-7. OCLC 933449409.
  5. ^ Berendt, Raymond D. (1967). A guide to airborne, impact, and structure borne noise-control in multifamily dwellings. U.S. Dept. of Housing and Urban Development. OCLC 5863574.
  6. ^ Bradley, J.S. (August 2001). Deriving Acceptable Values for Party Wall Sound Insulation from Survey Results. Inter-noise 2001 : The 2001 International Congress and Exhibition on Noise Control Engineering. The Hague, The Netherlands. ISBN 9789080655423. OCLC 48937099.
  7. ^ Cavanaugh, W.J.; Farrell, W.R.; Hirtle, P.W.; Watters, B.G. (April 1962). "Speech Privacy in Buildings". The Journal of the Acoustical Society of America. 34 (4): 475–492. Bibcode:1962ASAJ...34..475C. doi:10.1121/1.1918154. ISSN 0001-4966.
  8. ^ Knudsen, Vern O. (1988). Acoustical designing in architecture. Acoustical Society of America. ISBN 0-88318-267-X. OCLC 758181173.
  9. ^ Chrisler, V. L. (1939). Sound insulation of wall and floor constructions. U.S. G.P.O. OCLC 14104628.
  10. ^ Northwood, T. D. (April 1962). "Sound-Insulation Ratings and the New ASTM Sound-Transmission Class". The Journal of the Acoustical Society of America. 34 (4): 493–501. Bibcode:1962ASAJ...34..493N. doi:10.1121/1.1918155. ISSN 0001-4966.
  11. ^ Ballou 2008, pp. 72–73.
  12. ^ Ballou 2008, p. 89.
  13. ^ a b c d e Ballou, Glen, ed. (2015). Handbook for sound engineers (5th ed.). ISBN 978-1-135-01665-4. OCLC 913880162.
  14. ^ a b c d e f g Halliwell, R.E.; Nightingale, T.R.T.; Warnock, A.C.C.; Birta, J.A. (March 1998). "Gypsum Board Walls: Transmission Loss Data". National Research Council Canada. doi:10.4224/20331556. IRC-IR-761.
  15. ^ a b c Bétit, Aaron (March 2010). "Performance Details of Metal Stud Partitions" (PDF). Sound and Vibration Magazine: 14–16.
  16. ^ "ASTM E413-22 Classification for Rating Sound Insulation". ASTM International. May 2022.
  17. ^ Warnock, A.C.C. "Field sound transmission loss measurements". Building Research Note. 1985–06. doi:10.4224/40000485.
  18. ^ Ballou 2008, p. 97.
  19. ^ Brown, Steven M.; Niedzielski, Joseph; Spalding, G. Robert (1978). "Effect of sound-absorptive facings on partition airborne-sound transmission loss". The Journal of the Acoustical Society of America. 63 (6): 1851–1856. Bibcode:1978ASAJ...63.1851B. doi:10.1121/1.381924.
  20. ^ LoVerde, J.; Dong, W. (2010). "Quantitative comparisons of resilient channel design and installation in single wood stud walls" (PDF). Proceedings of 20th International Congress on Acoustics, ICA 2010.
  21. ^ Halliwell, R. E. (1998). Gypsum board walls : transmission loss data. Institute for Research in Construction. OCLC 155721225.
  22. ^ Davy, John L.; Fard, Mohammad; Dong, Wayland; Loverde, John (February 2019). "Empirical corrections for predicting the sound insulation of double leaf cavity stud building elements with stiffer studs". The Journal of the Acoustical Society of America. 145 (2): 703–713. Bibcode:2019ASAJ..145..703D. doi:10.1121/1.5089222. ISSN 0001-4966. PMID 30823783. S2CID 73462977.
  23. ^ Shafer, Benjamin M.; Tinianov, Brandon (October 2011). "Use of damped drywall in architectural acoustics". The Journal of the Acoustical Society of America. 130 (4): 2388. Bibcode:2011ASAJ..130R2388S. doi:10.1121/1.3654567. ISSN 0001-4966.
  24. ^ Tinianov, Brian D. (September 2005). "Two case studies: QuietRock QR-530 drywall panels in new and remediated multifamily construction". The Journal of the Acoustical Society of America. 118 (3): 1976. doi:10.1121/1.2097073. ISSN 0001-4966.
  25. ^ Acoustical glazing design guide : laminated glass with Saflex plastic interlayer for superior sound control. Monsanto Company. 1986. OCLC 38400395.
  26. ^ Ballou 2008, pp. 77–78.
  27. ^ . Archived from the original on 2010-03-15. Retrieved 2012-02-07. Acoustics in Practice
  28. ^ Shafer, Benjamin M. (2013). An overview of constrained-layer damping theory and application. Proceedings of Meetings on Acoustics. Vol. 133. Acoustical Society of America. p. 065023. Bibcode:2013ASAJ..133.3332S. doi:10.1121/1.4800606.
  29. ^ Shafer, Benjamin M.; Tinianov, Brandon (2011). "Use of damped drywall in architectural acoustics". The Journal of the Acoustical Society of America. 130 (4): 2388. Bibcode:2011ASAJ..130R2388S. doi:10.1121/1.3654567.
  30. ^ LoVerde, John; Dong, Wayland (2010). "Predictability of field airborne noise isolation from laboratory testing". The Journal of the Acoustical Society of America. 127 (3): 1741. Bibcode:2010ASAJ..127.1741L. doi:10.1121/1.3383509. ISSN 0001-4966.
  31. ^ ASTM E336-20 (2020). "Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings". Conshohocken, PA: ASTM International.{{cite web}}: CS1 maint: numeric names: authors list (link)
  32. ^ Standard Test Method for Measurement of the Normalized Insertion Loss of Doors, ASTM International, doi:10.1520/e2964-14
  33. ^ The Complete Photo Guide to Home Improvement. Creative Publishing international. July 2001. p. 194. ISBN 9780865735804. Retrieved 2011-10-01. The Complete Photo Guide to Home Improvement.
  34. ^ a b c d "STC Ratings for Masonry Walls". Acoustics.com. Retrieved 2011-10-01.
  35. ^ a b c "New Data Shows Masonry Wall and Precast Hollow Core Floor Systems Reaching High STC Ratings" (PDF). Masonry Advisory Council. Retrieved 2011-10-01.
  36. ^ Horan, Daniel (2014). "Computer Modeling of STC- Options and Accuracy" (PDF). Sound & Vibration (December): 8–11.
  37. ^ ASTM E1332-16 (2016). "Standard Classification for Rating Outdoor-Indoor Sound Attenuation". Conshohocken, PA: ASTM International.{{cite web}}: CS1 maint: numeric names: authors list (link)

Bibliography edit

  • Harris, Cyril M. (1994). Noise Control in Buildings: A Practical Guide for Architects and Engineers. McGraw-Hill. ISBN 978-0-07-026887-6. OCLC 869588871.
  • Ballou, Glenn M. (2008). Handbook for Sound Engineers (4th ed.). Elsevier. ISBN 978-0-240-80969-4.

sound, transmission, class, sound, transmission, class, integer, rating, well, building, partition, attenuates, airborne, sound, widely, used, rate, interior, partitions, ceilings, floors, doors, windows, exterior, wall, configurations, outside, sound, reducti. Sound Transmission Class or STC is an integer rating of how well a building partition attenuates airborne sound In the US it is widely used to rate interior partitions ceilings floors doors windows and exterior wall configurations Outside the US the ISO Sound Reduction Index SRI is used The STC rating very roughly reflects the decibel reduction of noise that a partition can provide The STC is useful for evaluating annoyance due to speech sounds but not music or machinery noise as these sources contain more low frequency energy than speech 1 There are many ways to improve the sound transmission class of a partition though the two most basic principles are adding mass and increasing the overall thickness In general the sound transmission class of a double wythe wall e g two 4 thick block walls separated by a 2 airspace is greater than a single wall of equivalent mass e g homogeneous 8 block wall 2 Contents 1 Definition 2 Subjective correlation 3 Rating methodology 3 1 Historical 3 2 Current 4 Factors affecting sound transmission class 4 1 Acoustic medium 4 2 Mass 4 3 Sound absorption 4 4 Stiffness 4 4 1 Framing methods 4 5 Damping 4 6 Sound leakage 4 7 Flanking 5 Special variations of STC 5 1 Composite STC 5 2 Apparent Sound Transmission Class ASTC 5 3 Normalized Noise Isolation Class NNIC 5 4 Noise Isolation Class NIC 5 5 Field Sound Transmission Class FSTC 5 6 Door Sound Transmission Class DTC 6 Legal and practical requirements 7 Common partition STC 8 STC prediction 9 Outdoor Indoor Transmission Class OITC 10 See also 11 References 12 BibliographyDefinition editThe STC or sound transmission class is a single number method of rating how well wall partitions reduce sound transmission 3 The STC provides a standardized way to compare products such as doors and windows made by competing manufacturers A higher number indicates more effective sound insulation than a lower number The STC is a standardized rating provided by ASTM E413 based on laboratory measurements performed in accordance with ASRM E90 ASTM E413 can also be used to determine similar ratings from field measurements performed in accordance with ASTM E336 3 Sound Isolation and Sound Insulation are used interchangeably though the term Insulation is preferred outside the US 4 The term sound proofing is typically avoided in architectural acoustics as it is a misnomer and connotes inaudibility Subjective correlation editThrough research acousticians have developed tables that pair a given STC rating with a subjective experience The table below is used to determine the degree of sound isolation provided by typical multi family construction Generally a difference of one or two STC points between similar constructions is subjectively insignificant 5 STCs by audio distinguishability STC What can be heard25 Normal speech can be understood30 Loud speech can be understood35 Loud speech audible but not intelligible40 Loud speech audible as a murmur45 Loud speech heard but not audible50 Loud sounds faintly heard60 Good soundproofing most sounds do not disturb neighboring residents 6 Tables like the one above are highly dependent on the background noise levels in the receiving room the louder the background noise the greater the perceived sound isolation 7 Rating methodology editHistorical edit Prior to the STC rating the sound isolation performance of a partition was measured and reported as the average transmission loss of over the frequency range 128 to 4096 Hz or 256 to 1021 Hz 8 9 This method is valuable at comparing homogeneous partitions that follow the mass law but can be misleading when comparing complex or multi leaf walls In 1961 the ASTM International Standards Organization adopted E90 61T which served as the basis for the STC method used today The STC standard curve is based on European studies of multi family residential construction and closely resembles the sound isolation performance of a 9 thick brick wall 10 Current edit nbsp Sound Transmission Class Report Sample from NTi Audio showing Transmission Loss in the sixteen standard frequenciesThe STC number is derived from sound attenuation values tested at sixteen standard frequencies from 125 Hz to 4000 Hz These Transmission Loss values are then plotted on a sound pressure level graph and the resulting curve is compared to a standard reference contour provided by the ASTM 11 Sound isolation metrics such as the STC are measured in specially isolated and designed laboratory test chambers There are nearly infinite field conditions that will affect sound isolation on site when designing building partitions and enclosures Factors affecting sound transmission class editAcoustic medium edit Sound travels through both the air and structure and both paths must be considered when designing sound isolating walls and ceilings To eliminate air borne sound all air paths between the areas must be eliminated This is achieved by making seams airtight and closing all sound leaks To eliminate structure borne noise one must create isolation systems that reduce mechanical connections between those structures 12 Mass edit Adding mass to a partition reduces the transmission of sound This is often achieved by adding additional layers of gypsum It is preferable to have non symmetrical leaves for example with different thickness gypsum 13 The effect of adding multiple layers of gypsum wallboard to a frame also varies depending on the framing type and configuration 14 15 Doubling the mass of a partition does not double the STC as the STC is calculated from a non linear decibel sound transmission loss measurement 16 So whereas installing an additional layer of gypsum wallboard to a light gauge 25 ga or lighter steel stud partition will result in about a 5 STC point increase doing the same on single wood or single heavy gauge steel will result in only 2 to 3 additional STC points 14 15 Adding a second additional layer to the already 3 layer system does not result in as drastic an STC change as the first additional layer 14 The effect of additional gypsum wallboard layers on double and staggered stud partitions is similar to that of light gauge steel partitions Due to increased mass poured concrete and concrete blocks typically achieve higher STC values in the mid STC 40s to the mid STC 50s than equally thick framed walls 17 However the additional weight added complexity of construction and poor thermal insulation tend to limit masonry wall partitions as a viable sound isolation solution in many building construction projects In recent years gypsum board manufacturers have started to offer lightweight drywall board Normal weight gypsum has a nominal density of 43pcf and lightweight drywall has a nominal density of 36pcf This does not have a large effect on the STC rating though lightweight gypsum can significantly degrade the low frequency performance of a partition as compared to normal weight gypsum Sound absorption edit Sound absorption entails turning acoustical energy into some other form of energy usually heat 18 Adding absorptive materials to the interior surfaces of rooms for example fabric faced fiberglass panels and thick curtains will result in a decrease of reverberated sound energy within the room However absorptive interior surface treatments of this kind do not significantly improve the sound transmission class 19 Installing absorptive insulation for example fiberglass batts and blow in cellulose into the wall or ceiling cavities does increase the sound transmission class significantly 14 The presence of insulation in single 2x4 wood stud framing spaced 16 406 mm on center results in only a few STC points This is because a wall with 2x4 wood stud framing spaced 16 develops significant resonances which are not mitigated by the cavity insulation In contrast adding standard fiberglass insulation to an otherwise empty cavity in light gauge 25 gauge or lighter steel stud partitions can result in a nearly 10 STC point improvement Other studies have shown that fibrous insulation materials such as mineral wool can increase the STC by 5 to 8 points 13 Stiffness edit The effect of stiffness on sound isolation can relate to either the material stiffness of the sound isolating material or the stiffness caused by framing methods Framing methods edit Structurally decoupling the gypsum wallboard panels from the partition framing can result in a large increase in sound isolation when installed correctly Examples of structural decoupling in building construction include resilient channels sound isolation clips and hat channels and staggered or double stud framing The STC results of decoupling in wall and ceiling assemblies varies significantly depending on the framing type air cavity volume and decoupling material type 14 Great care must be taken in each type of decoupled partition construction as any fastener that becomes mechanically rigidly coupled to the framing can undermine the decoupling and result in drastically lower sound isolation results 20 When two leaves are rigidly tied or coupled by a stud the sound isolation of the system depends on the stiffness of the stud Light gauge 25 gauge or lighter provides better sound isolation than 16 20 gauge steel and noticeably better performance than wood studs 21 When heavy gauge steel or wood studs are spaced 16 on center additional resonances form which further lower the sound isolation performance of a partition For typical gypsum stud walls this resonance occurs in the 100 160 Hz region and is thought to be a hybrid of the mass air mass resonance and a bending mode resonance caused when a plate is closely supported by stiff members 22 Single metal stud partitions are more effective than single wood stud partitions and have been shown to increase the STC rating by up to 10 points However there is little difference between metal and wood studs when used in double stud partitions 13 Double stud partitions have a higher STC than single stud 13 In certain assemblies increasing the stud spacing from 16 to 24 inches increases the STC rating by 2 to 3 points 13 Damping edit Though the terms sound absorption and damping are often interchangeable when discussing room acoustics acousticians define these as two distinct properties of sound isolating walls Several gypsum manufacturers offer specialty products which use constrained layer damping which is a form of viscous damping 23 24 Damping generally increases the sound isolation of partitions particularly at mid and high frequencies Damping is also used to improve the sound isolation performance of glazing assemblies Laminated glazing which consists of a Polyvinyl butyral or PVB inter layer performs better acoustically than a non laminated glass of equivalent thickness 25 Sound leakage edit nbsp A small gap in the wall can greatly reduce the STC rating This wall did not receive a full perimeter seal All holes and gaps should be filled and the enclosure hermetically sealed for sound isolation to be effective The table below illustrates sound proofing test results from a wall partition that has a theoretical maximum loss of 40 dB from one room to the next and a partition area of 10 meters squared Even small open gaps and holes in the partition have a disproportionate reduction in sound proofing A 5 opening in the partition which offers unrestricted sound transmission from one room to the next caused the transmission loss to reduce from 40 dB to 13 dB A 0 1 open area will reduce the transmission loss from 40 dB to 30 dB which is typical of walls where caulking has not been applied effectively 26 Partitions that are inadequately sealed and contain back to back electrical boxes untreated recessed lighting and unsealed pipes offer flanking paths for sound and significant leakage 27 Acoustic joint tapes and caulking have been used to improve sound isolation since the early 1930s 28 Although the applications of tapes was largely limited to defense and industrial applications such as naval vessels and aircraft in the past recent research has proven the effectiveness of sealing gaps and thereby improving the sound isolation performance of a partition 29 Sound diminution by percentage openness of barrier Transmission loss of area open13 dB 5 open17 dB 2 open20 dB 1 open23 dB 0 5 open27 dB 0 2 open30 dB 0 1 open33 dB 0 05 open37 dB 0 02 open39 5 dB Practical maximum loss40 dB Theoretical maximum lossFlanking edit Building codes typically allow for a 5 point tolerance between the lab tested and field measured STC rating however studies have shown that even in well built and sealed installations the difference between the lab and field rating is highly dependent on the type of assembly 30 Special variations of STC editBy nature the STC rating is derived from lab testing under ideal conditions There are other versions of the STC rating to account for real world conditions Composite STC edit The net sound isolation performance of a partition containing multiple sound isolating elements such as doors windows etc Apparent Sound Transmission Class ASTC edit The sound isolation performance of a partition measured in the field according to ASTM E336 normalized to account for different room finishes and the area of the tested partition i e compare the same wall measured in a bare living room and an acoustically dry recording booth Normalized Noise Isolation Class NNIC edit The sound isolation performance of a partition measured in the field according to ASTM E336 normalized to account for the reverberation time in the room Noise Isolation Class NIC edit The sound isolation performance of a partition measured in the field according to ASTM E336 not normalized to the room conditions of the test Field Sound Transmission Class FSTC edit The sound isolation performance of a specific elements in a partition as measured in the field and achieved by suppressing the effects of sound flanking paths This can be useful for measuring walls with doors when you are interested in removing the influence of the door on the measured field STC The FSTC testing method was historically prescribed by ASTM E336 however the latest version of this standard does not include FSTC 31 Door Sound Transmission Class DTC edit The sound isolation performance of doors when measured according to ASTM E2964 32 Legal and practical requirements editSection 1206 of International Building Code 2021 states that separation between dwelling units and public and service areas must achieve STC 50 where tested in accordance with ASTM E90 or NNIC 45 if field tested in accordance with ASTM E336 However not all jurisdictions use the IBC for their building or municipal code Common partition STC editInterior walls with 1 sheet of 1 2 13 mm gypsum wallboard drywall on either side of 2x4 90 mm wood studs spaced 16 406 mm on center with no fiberglass insulation filling each stud cavity have an STC of about 33 14 When asked to rate their acoustical performance people often describe these walls as paper thin They offer little in the way of privacy Double stud partition walls are typically constructed with varying gypsum wallboard panel layers attached to both sides of double 2x4 90 mm wood studs spaced 16 406 mm on center and separated by a 1 25 mm airspace These walls vary in sound isolation performance from the mid STC 40s into the high STC 60s depending on the presence of insulation and the gypsum wallboard type and quantity 14 Commercial buildings are typically constructed using steel studs of varying widths gauges and on center spacings Each of these framing characteristics have an effect on the sound isolation of the partition to varying degrees 15 STCs by partition type STC Partition type27 Single pane glass window typical value dual pane glass window range is 26 32 STC Ratings 33 Single layer of 1 2 drywall on each side wood studs no insulation typical interior wall 39 Single layer of 1 2 drywall on each side wood studs fiberglass insulation 33 44 4 hollow CMU concrete masonry unit 34 45 Double layer of 1 2 drywall on each side wood studs batt insulation in wall46 Single layer of 1 2 drywall glued to 6 lightweight concrete block wall painted both sides46 6 hollow CMU concrete masonry unit 34 48 8 hollow CMU concrete masonry unit 34 50 10 hollow CMU concrete masonry unit 34 52 8 hollow CMU concrete masonry unit with 2 Z bars and 1 2 drywall on each side 35 54 Single layer of 1 2 drywall glued to 8 dense concrete block wall painted both sides54 8 hollow CMU concrete masonry unit with 1 1 2 wood furring 1 1 2 fiberglass insulation and 1 2 drywall on each side 35 55 Double layer of 1 2 drywall on each side on staggered wood stud wall batt insulation in wall59 Double layer of 1 2 drywall on each side on wood stud wall resilient channels on one side batt insulation63 Double layer of 1 2 drywall on each side on double wood metal stud walls spaced 1 apart double batt insulation64 8 hollow CMU concrete masonry unit with 3 steel studs fiberglass insulation and 1 2 drywall on each side 35 72 8 concrete block wall painted with 1 2 drywall on independent steel stud walls each side insulation in cavitiesSTC prediction editThere are several commercially available software which predict the STC ratings of partitions using a combination of theoretical models and empirically derived lab data These programs can predict STC ratings within several points of a tested partition and are an approximation at best 36 Outdoor Indoor Transmission Class OITC editThe Outdoor Indoor Transmission Class OITC is a standard used for indicating the rate of sound transmission from outdoor noise sources into a building It is based on the ASTM E 1332 Standard Classification for Rating Outdoor Indoor Sound Attenuation 37 Unlike the STC which is based on a noise spectrum targeting speech sounds OITC uses a source noise spectrum that considers frequencies down to 80 Hz aircraft rail truck traffic and is weighted more to lower frequencies The OITC value is typically used to rate evaluate and select exterior glazing assemblies See also editAcoustics Architectural acoustics Construction Impact insulation class Noise Noise control Noise reduction Sound Reduction Index SoundproofingReferences edit Roller H Stanley November 1985 Isolating music and mechanical equipment sound sources with gypsum board partition systems The Journal of the Acoustical Society of America 78 S1 S10 Bibcode 1985ASAJ 78 10R doi 10 1121 1 2022641 ISSN 0001 4966 Egan M David 2007 Architectural acoustics J Ross Publishing ISBN 978 1 932159 78 3 OCLC 636858059 a b Ballou 2008 p 72 Hopkins Carl 2016 Sound insulation Routledge ISBN 978 1 138 13770 7 OCLC 933449409 Berendt Raymond D 1967 A guide to airborne impact and structure borne noise control in multifamily dwellings U S Dept of Housing and Urban Development OCLC 5863574 Bradley J S August 2001 Deriving Acceptable Values for Party Wall Sound Insulation from Survey Results Inter noise 2001 The 2001 International Congress and Exhibition on Noise Control Engineering The Hague The Netherlands ISBN 9789080655423 OCLC 48937099 Cavanaugh W J Farrell W R Hirtle P W Watters B G April 1962 Speech Privacy in Buildings The Journal of the Acoustical Society of America 34 4 475 492 Bibcode 1962ASAJ 34 475C doi 10 1121 1 1918154 ISSN 0001 4966 Knudsen Vern O 1988 Acoustical designing in architecture Acoustical Society of America ISBN 0 88318 267 X OCLC 758181173 Chrisler V L 1939 Sound insulation of wall and floor constructions U S G P O OCLC 14104628 Northwood T D April 1962 Sound Insulation Ratings and the New ASTM Sound Transmission Class The Journal of the Acoustical Society of America 34 4 493 501 Bibcode 1962ASAJ 34 493N doi 10 1121 1 1918155 ISSN 0001 4966 Ballou 2008 pp 72 73 Ballou 2008 p 89 a b c d e Ballou Glen ed 2015 Handbook for sound engineers 5th ed ISBN 978 1 135 01665 4 OCLC 913880162 a b c d e f g Halliwell R E Nightingale T R T Warnock A C C Birta J A March 1998 Gypsum Board Walls Transmission Loss Data National Research Council Canada doi 10 4224 20331556 IRC IR 761 a b c Betit Aaron March 2010 Performance Details of Metal Stud Partitions PDF Sound and Vibration Magazine 14 16 ASTM E413 22 Classification for Rating Sound Insulation ASTM International May 2022 Warnock A C C Field sound transmission loss measurements Building Research Note 1985 06 doi 10 4224 40000485 Ballou 2008 p 97 Brown Steven M Niedzielski Joseph Spalding G Robert 1978 Effect of sound absorptive facings on partition airborne sound transmission loss The Journal of the Acoustical Society of America 63 6 1851 1856 Bibcode 1978ASAJ 63 1851B doi 10 1121 1 381924 LoVerde J Dong W 2010 Quantitative comparisons of resilient channel design and installation in single wood stud walls PDF Proceedings of 20th International Congress on Acoustics ICA 2010 Halliwell R E 1998 Gypsum board walls transmission loss data Institute for Research in Construction OCLC 155721225 Davy John L Fard Mohammad Dong Wayland Loverde John February 2019 Empirical corrections for predicting the sound insulation of double leaf cavity stud building elements with stiffer studs The Journal of the Acoustical Society of America 145 2 703 713 Bibcode 2019ASAJ 145 703D doi 10 1121 1 5089222 ISSN 0001 4966 PMID 30823783 S2CID 73462977 Shafer Benjamin M Tinianov Brandon October 2011 Use of damped drywall in architectural acoustics The Journal of the Acoustical Society of America 130 4 2388 Bibcode 2011ASAJ 130R2388S doi 10 1121 1 3654567 ISSN 0001 4966 Tinianov Brian D September 2005 Two case studies QuietRock QR 530 drywall panels in new and remediated multifamily construction The Journal of the Acoustical Society of America 118 3 1976 doi 10 1121 1 2097073 ISSN 0001 4966 Acoustical glazing design guide laminated glass with Saflex plastic interlayer for superior sound control Monsanto Company 1986 OCLC 38400395 Ballou 2008 pp 77 78 Acoustics in Practice NRC CNRC Archived from the original on 2010 03 15 Retrieved 2012 02 07 Acoustics in Practice Shafer Benjamin M 2013 An overview of constrained layer damping theory and application Proceedings of Meetings on Acoustics Vol 133 Acoustical Society of America p 065023 Bibcode 2013ASAJ 133 3332S doi 10 1121 1 4800606 Shafer Benjamin M Tinianov Brandon 2011 Use of damped drywall in architectural acoustics The Journal of the Acoustical Society of America 130 4 2388 Bibcode 2011ASAJ 130R2388S doi 10 1121 1 3654567 LoVerde John Dong Wayland 2010 Predictability of field airborne noise isolation from laboratory testing The Journal of the Acoustical Society of America 127 3 1741 Bibcode 2010ASAJ 127 1741L doi 10 1121 1 3383509 ISSN 0001 4966 ASTM E336 20 2020 Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings Conshohocken PA ASTM International a href Template Cite web html title Template Cite web cite web a CS1 maint numeric names authors list link Standard Test Method for Measurement of the Normalized Insertion Loss of Doors ASTM International doi 10 1520 e2964 14 The Complete Photo Guide to Home Improvement Creative Publishing international July 2001 p 194 ISBN 9780865735804 Retrieved 2011 10 01 The Complete Photo Guide to Home Improvement a b c d STC Ratings for Masonry Walls Acoustics com Retrieved 2011 10 01 a b c New Data Shows Masonry Wall and Precast Hollow Core Floor Systems Reaching High STC Ratings PDF Masonry Advisory Council Retrieved 2011 10 01 Horan Daniel 2014 Computer Modeling of STC Options and Accuracy PDF Sound amp Vibration December 8 11 ASTM E1332 16 2016 Standard Classification for Rating Outdoor Indoor Sound Attenuation Conshohocken PA ASTM International a href Template Cite web html title Template Cite web cite web a CS1 maint numeric names authors list link Bibliography editHarris Cyril M 1994 Noise Control in Buildings A Practical Guide for Architects and Engineers McGraw Hill ISBN 978 0 07 026887 6 OCLC 869588871 Ballou Glenn M 2008 Handbook for Sound Engineers 4th ed Elsevier ISBN 978 0 240 80969 4 Retrieved from https en wikipedia org w index php title Sound transmission class amp oldid 1187986987, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.