A pressure regulator is a valve that controls the pressure of a fluid or gas to a desired value, using negative feedback from the controlled pressure. Regulators are used for gases and liquids, and can be an integral device with a pressure setting, a restrictor and a sensor all in the one body, or consist of a separate pressure sensor, controller and flow valve.

Oxygen and MAPP gas cylinders with two-stage pressure regulators
Schematic diagram of pressure reducing regulator (A) and back-pressure regulator (B). The upper diagrams show the normal state for the valves, which is normally open for pressure reducers and normally closed for back-pressure valves.
  • 1. Pressure setting screw
  • 2. Spring
  • 3. Actuator
  • 4. Inlet port (high pressure)
  • 5. Outlet port (low pressure)
  • 6. Valve body
  • 7. Valve crown and seat
Diagram symbols for pressure reduction and back pressure regulators. The conceptual difference is mainly in which side the feedback is taken from.

Two types are found: The pressure reduction regulator and the back-pressure regulator.

  • A pressure reducing regulator is a control valve that reduces the input pressure of a fluid or gas to a desired value at its output. It is a normally-open valve and is installed upstream of pressure sensitive equipment.[1]

  • A back-pressure regulator, back-pressure valve, pressure sustaining valve or pressure sustaining regulator is a control valve that maintains the set pressure at its inlet side by opening to allow flow when the inlet pressure exceeds the set value. It differs from an over-pressure relief valve in that the over-pressure valve is only intended to open when the contained pressure is excessive, and it is not required to keep upstream pressure constant. They differ from pressure reducing regulators in that the pressure reducing regulator controls downstream pressure and is insensitive to upstream pressure.[2] It is a normally-closed valve which may be installed in parallel with sensitive equipment or after the sensitive equipment to provide an obstruction to flow and thereby maintain upstream pressure.[1]

Both types of regulator use feedback of the regulated pressure as input to the control mechanism, and are commonly actuated by a spring loaded diaphragm or piston reacting to changes in the feedback pressure to control the valve opening, and in both cases the valve should be opened only enough to maintain the set regulated pressure. The actual mechanism may be very similar in all respects except the placing of the feedback pressure tap.[2] As in other feedback control mechanisms, the level of damping is important to achieve a balance between fast response to a change in the measured pressure, and stability of output. Insufficient damping may lead to hunting oscillation of the controlled pressure, while excessive friction of moving parts may cause hysteresis.

Pressure reducing regulator

Operation

A pressure reducing regulator's primary function is to match the flow of gas through the regulator to the demand for gas placed upon it, whilst maintaining a sufficiently constant output pressure. If the load flow decreases, then the regulator flow must decrease as well. If the load flow increases, then the regulator flow must increase in order to keep the controlled pressure from decreasing due to a shortage of gas in the pressure system. It is desirable that the controlled pressure does not vary greatly from the set point for a wide range of flow rates, but it is also desirable that flow through the regulator is stable and the regulated pressure is not subject to excessive oscillation.[citation needed]

A pressure regulator includes a restricting element, a loading element, and a measuring element:

  • The restricting element is a valve that can provide a variable restriction to the flow, such as a globe valve, butterfly valve, poppet valve, etc.
  • The loading element is a part that can apply the needed force to the restricting element. This loading can be provided by a weight, a spring, a piston actuator, or the diaphragm actuator in combination with a spring.
  • The measuring element functions to determine when the inlet flow is equal to the outlet flow. The diaphragm itself is often used as a measuring element; it can serve as a combined element.[citation needed]

In the pictured single-stage regulator, a force balance is used on the diaphragm to control a poppet valve in order to regulate pressure. With no inlet pressure, the spring above the diaphragm pushes it down on the poppet valve, holding it open. Once inlet pressure is introduced, the open poppet allows flow to the diaphragm and pressure in the upper chamber increases, until the diaphragm is pushed upward against the spring, causing the poppet to reduce flow, finally stopping further increase of pressure. By adjusting the top screw, the downward pressure on the diaphragm can be increased, requiring more pressure in the upper chamber to maintain equilibrium. In this way, the outlet pressure of the regulator is controlled.[citation needed]

 
 

 
 
 
 

 

Single stage regulator

 
Single-stage pressure regulator

High pressure gas from the supply enters the regulator through the inlet port. The inlet pressure gauge will indicate this pressure. The gas then passes through the normally open pressure control valve orifice and the downstream pressure rises until the valve actuating diaphragm is deflected sufficiently to close the valve, preventing any more gas from entering the low pressure side until the pressure drops again. The outlet pressure gauge will indicate this pressure.[citation needed]

The outlet pressure on the diaphragm and the inlet pressure and poppet spring force on the upstream part of the valve hold the diaphragm/poppet assembly in the closed position against the force of the diaphragm loading spring. If the supply pressure falls, the closing force due to supply pressure is reduced, and downstream pressure will rise slightly to compensate. Thus, if the supply pressure falls, the outlet pressure will increase, provided the outlet pressure remains below the falling supply pressure. This is the cause of end-of-tank dump where the supply is provided by a pressurized gas tank.[citation needed] The operator can compensate for this effect by adjusting the spring load by turning the knob to restore outlet pressure to the desired level. With a single stage regulator, when the supply pressure gets low, the lower inlet pressure causes the outlet pressure to climb. If the diaphragm loading spring compression is not adjusted to compensate, the poppet can remain open and allow the tank to rapidly dump its remaining contents.[citation needed]

Double stage regulator

 
Two-stage pressure regulator

Two stage regulators are two regulators in series in the same housing that operate to reduce the pressure progressively in two steps instead of one. The first stage, which is preset, reduces the pressure of the supply gas to an intermediate stage; gas at that pressure passes into the second stage. The gas emerges from the second stage at a pressure (working pressure) set by user by adjusting the pressure control knob at the diaphragm loading spring. Two stage regulators may have two safety valves, so that if there is any excess pressure between stages due to a leak at the first stage valve seat the rising pressure will not overload the structure and cause an explosion.[citation needed]

An unbalanced single stage regulator may need frequent adjustment. As the supply pressure falls, the outlet pressure may change, necessitating adjustment. In the two stage regulator, there is improved compensation for any drop in the supply pressure.[citation needed]

Applications

Pressure reducing regulators

Air compressors

Air compressors are used in industrial, commercial, and home workshop environments to perform an assortment of jobs including blowing things clean; running air powered tools; and inflating things like tires, balls, etc. Regulators are often used to adjust the pressure coming out of an air receiver (tank) to match what is needed for the task. Often, when one large compressor is used to supply compressed air for multiple uses (often referred to as "shop air" if built as a permanent installation of pipes throughout a building), additional regulators will be used to ensure that each separate tool or function receives the pressure it needs. This is important because some air tools, or uses for compressed air, require pressures that may cause damage to other tools or materials.[citation needed]

Aircraft

Pressure regulators are found in aircraft cabin pressurization, canopy seal pressure control, potable water systems, and waveguide pressurization.[3]

Aerospace

Aerospace pressure regulators have applications in propulsion pressurant control for reaction control systems (RCS) and Attitude Control Systems (ACS), where high vibration, large temperature extremes and corrosive fluids are present.[4]

Cooking

Pressurized vessels can be used to cook food much more rapidly than at atmospheric pressure, as the higher pressure raises the boiling point of the contents. All modern pressure cookers will have a pressure regulator valve and a pressure relief valve as a safety mechanism to prevent explosion in the event that the pressure regulator valve fails to adequately release pressure. Some older models lack a safety release valve[citation needed]. Most home cooking models are built to maintain a low and high pressure setting. These settings are usually 7 to 15 pounds per square inch (0.48 to 1.03 bar). Almost all home cooking units will employ a very simple single-stage pressure regulator. Older models will simply use a small weight on top of an opening that will be lifted by excessive pressure to allow excess steam to escape. Newer models usually incorporate a spring-loaded valve that lifts and allows pressure to escape as pressure in the vessel rises. Some pressure cookers will have a quick release setting on the pressure regulator valve that will, essentially, lower the spring tension to allow the pressure to escape at a quick, but still safe rate. Commercial kitchens also use pressure cookers, in some cases using oil based pressure cookers to quickly deep fry fast food. Pressure vessels of this sort can also be used as autoclaves to sterilize small batches of equipment and in home canning operations.[citation needed]

Water pressure reduction

 
Pressure regulator for domestic water supply. Outlet pressure is set with the blue handwheel and shown on the vertical scale.

A water pressure regulating valve limits inflow by dynamically changing the valve opening so that when less pressure is on the out side, the valve opens up fully, and too much pressure on the out side causes the valve to shut. In a no pressure situation, where water could flow backwards, it won't be impeded. A water pressure regulating valve does not function as a check valve.

They are used in applications where the water pressure is too high at the end of the line to avoid damage to appliances or pipes.

Welding and cutting

Oxy-fuel welding and cutting processes require gases at specific pressures, and regulators will generally be used to reduce the high pressures of storage cylinders to those usable for cutting and welding. Oxygen and fuel gas regulators usually have two stages: The first stage of the regulator releases the gas at a constant pressure from the cylinder despite the pressure in the cylinder becoming less as the gas is released. The second stage of the regulator controls the pressure reduction from the intermediate pressure to low pressure. The final flow rate may be adjusted at the torch. The regulator assembly usually has two pressure gauges, one indicating cylinder pressure, the other indicating delivery pressure. Inert gas shielded arc welding also uses gas stored at high pressure provided through a regulator. There may be a flow gauge calibrated to the specific gas.[citation needed]

Propane/LP Gas

All propane and LP Gas applications require the use of a regulator. Because pressures in propane tanks can fluctuate significantly with temperature, regulators must be present to deliver a steady pressure to downstream appliances. These regulators normally compensate for tank pressures between 30–200 pounds per square inch (2.1–13.8 bar) and commonly deliver 11 inches water column 0.4 pounds per square inch (28 mbar) for residential applications and 35 inches of water column 1.3 pounds per square inch (90 mbar) for industrial applications. Propane regulators differ in size and shape, delivery pressure and adjustability, but are uniform in their purpose to deliver a constant outlet pressure for downstream requirements. Common international settings for domestic LP Gas regulators are 28 mbar for butane and 37 mbar for propane.

Gas powered vehicles

All vehicular motors that run on compressed gas as a fuel (internal combustion engine or fuel cell electric power train) require a pressure regulator to reduce the stored gas (CNG or Hydrogen) pressure from 700, 500, 350 or 200 bar (or 70, 50, 35 and 20 MPa) to operating pressure.[citation needed])

Recreational vehicles

For recreational vehicles with plumbing, a pressure regulator is required to reduce the pressure of an external water supply connected to the vehicle plumbing, as the supply may be a much higher elevation than the campground, and water pressure depends on the height of the water column. Without a pressure regulator, the intense pressure encountered at some campgrounds in mountainous areas may be enough to burst the camper's water pipes or unseat the plumbing joints, causing flooding. Pressure regulators for this purpose are typically sold as small screw-on accessories that fit inline with the hoses used to connect an RV to the water supply, which are almost always screw-thread-compatible with the common garden hose.[citation needed]

Breathing gas supply

Pressure regulators are used with Diving cylinders for Scuba diving. The tank may contain pressures in excess of 3,000 pounds per square inch (210 bar), which could cause a fatal barotrauma injury to a person breathing it directly. A demand controlled regulator provides a flow of breathing gas at the ambient pressure (which varies by depth in the water). Pressure reducing regulators are also use to supply breathing gas to surface-supplied divers,[5] and people who use self-contained breathing apparatus for rescue and hazmat work on land. Supplementary oxygen for high altitude flight in unpressurised aircraft and medical gases are also dispensed through pressure reducing regulators from high-pressure storage.[citation needed]

Mining Industry

As the pressure builds rapidly in relation to depth, underground mining operations require a fairly complex water system with pressure reducing valves. These devices must be installed at a certain distance interval, usually 600 feet (180 m).[citation needed][clarification needed] Without such valves, pipes would easily burst and pressure would be too great for equipment operation.

Natural Gas Industry

Pressure regulators are used extensively within the natural gas industry. Natural gas is compressed to high pressures in order to be distributed throughout the country through large transmission pipelines. The transmission pressure can be over 1,000 pounds per square inch (69 bar) and must be reduced through various stages to a usable pressure for industrial, commercial, and residential applications. There are three main pressure reduction locations in this distribution system. The first reduction is located at the city gate, whereas the transmission pressure is dropped to a distribution pressure to feed throughout the city. This is also the location where the odorless natural gas is odorized with mercaptan. The distribution pressure is further reduced at a district regulator station, located at various points in the city, to below 60 psig. The final cut would occur at the end users location. Generally, the end user reduction is taken to low pressures ranging from 0.25 psig to 5 psig. Some industrial applications can require a higher pressure.[citation needed]

Back-pressure regulators

  • Maintain upstream pressure control in analytical or process systems[1]
  • Protect sensitive equipment from overpressure damage[1]
  • Reduce the pressure difference over a component which is not tolerant of large pressure differences.[6]
  • Gas sales lines[7]
  • Production vessels (e.g., Separators, heater treaters or free water knockouts)[7]
  • Vent or flare lines[7]

Hyperbaric chambers

Where the pressure drop on a built-in breathing system exhaust system is too great, typically in saturation systems, a back-pressure regulator may be used to reduce the exhaust pressure drop to a safer and more manageable pressure.[6][8]

Reclaim diving helmets

The depth at which most heliox breathing mixtures are used in surface-supplied diving is generally at least 5 bar above surface atmospheric pressure, and the exhaust gas from the diver must pass through a reclaim valve, which is a demand controlled back-pressure valve activated by the increase in pressure in the diver's helmet caused by diver exhalation.[9][10] The reclaim gas hose which carries the exhaled gas back to the surface for recycling must not be at too great a pressure difference from the ambient pressure at the diver. An additional back-pressure regulator in this line allows finer setting of the reclaim valve for lower work of breathing at variable depths.[11]

See also

References

  1. ^ a b c d "Pressure Regulator vs. Backpressure Regulator: When to use one or the other…and when to use both!". plastomatic.com. Retrieved 19 March 2020.
  2. ^ a b "Definition of Back Pressure Regulator: What do back pressure regulators do?". www.equilibar.com. Retrieved 19 March 2020.>
  3. ^ "Aircraft Pressure Regulators". www.valcor.com. Retrieved 19 March 2020.
  4. ^ "Aerospace Pressure Regulators". www.valcor.com. Retrieved 19 March 2020.
  5. ^ NOAA Diving Program (U.S.) (28 February 2001). Joiner, James T (ed.). NOAA Diving Manual, Diving for Science and Technology (4th ed.). Silver Spring, Maryland: National Oceanic and Atmospheric Administration, Office of Oceanic and Atmospheric Research, National Undersea Research Program. ISBN 978-0-941332-70-5. CD-ROM prepared and distributed by the National Technical Information Service (NTIS)in partnership with NOAA and Best Publishing Company
  6. ^ a b (PDF). Aberdeen, Scotland: C-Tecnics Ltd. Archived from the original (PDF) on 25 September 2018. Retrieved 25 September 2018.
  7. ^ a b c Jeff Port (21 May 2019). "Back Pressure Regulator vs Pressure Reducing Regulator: What's the Difference?". blog.kimray.com. Retrieved 19 March 2020.
  8. ^ "Divex back pressure regulator". Retrieved 19 March 2020.
  9. ^ "Gas reclaim back pressure regulator". Retrieved 19 March 2020 – via patents.google.com.
  10. ^ "Helmet gas reclaim valve". www.subspec.it. Retrieved 19 March 2020.
  11. ^ "Reclaim Basic Set Up" (PDF). www.subseasa.com. Retrieved 10 March 2020.

External links

  • Pressure Animations

pressure, regulator, pressure, regulator, valve, that, controls, pressure, fluid, desired, value, using, negative, feedback, from, controlled, pressure, regulators, used, gases, liquids, integral, device, with, pressure, setting, restrictor, sensor, body, cons. A pressure regulator is a valve that controls the pressure of a fluid or gas to a desired value using negative feedback from the controlled pressure Regulators are used for gases and liquids and can be an integral device with a pressure setting a restrictor and a sensor all in the one body or consist of a separate pressure sensor controller and flow valve Oxygen and MAPP gas cylinders with two stage pressure regulators Schematic diagram of pressure reducing regulator A and back pressure regulator B The upper diagrams show the normal state for the valves which is normally open for pressure reducers and normally closed for back pressure valves 1 Pressure setting screw2 Spring3 Actuator4 Inlet port high pressure 5 Outlet port low pressure 6 Valve body7 Valve crown and seat Diagram symbols for pressure reduction and back pressure regulators The conceptual difference is mainly in which side the feedback is taken from Two types are found The pressure reduction regulator and the back pressure regulator A pressure reducing regulator is a control valve that reduces the input pressure of a fluid or gas to a desired value at its output It is a normally open valve and is installed upstream of pressure sensitive equipment 1 A back pressure regulator back pressure valve pressure sustaining valve or pressure sustaining regulator is a control valve that maintains the set pressure at its inlet side by opening to allow flow when the inlet pressure exceeds the set value It differs from an over pressure relief valve in that the over pressure valve is only intended to open when the contained pressure is excessive and it is not required to keep upstream pressure constant They differ from pressure reducing regulators in that the pressure reducing regulator controls downstream pressure and is insensitive to upstream pressure 2 It is a normally closed valve which may be installed in parallel with sensitive equipment or after the sensitive equipment to provide an obstruction to flow and thereby maintain upstream pressure 1 Both types of regulator use feedback of the regulated pressure as input to the control mechanism and are commonly actuated by a spring loaded diaphragm or piston reacting to changes in the feedback pressure to control the valve opening and in both cases the valve should be opened only enough to maintain the set regulated pressure The actual mechanism may be very similar in all respects except the placing of the feedback pressure tap 2 As in other feedback control mechanisms the level of damping is important to achieve a balance between fast response to a change in the measured pressure and stability of output Insufficient damping may lead to hunting oscillation of the controlled pressure while excessive friction of moving parts may cause hysteresis Contents 1 Pressure reducing regulator 1 1 Operation 1 2 Single stage regulator 1 3 Double stage regulator 2 Applications 2 1 Pressure reducing regulators 2 1 1 Air compressors 2 1 2 Aircraft 2 1 3 Aerospace 2 1 4 Cooking 2 1 5 Water pressure reduction 2 1 6 Welding and cutting 2 1 7 Propane LP Gas 2 1 8 Gas powered vehicles 2 1 9 Recreational vehicles 2 1 10 Breathing gas supply 2 1 11 Mining Industry 2 1 12 Natural Gas Industry 2 2 Back pressure regulators 2 2 1 Hyperbaric chambers 2 2 2 Reclaim diving helmets 3 See also 4 References 5 External linksPressure reducing regulator EditOperation Edit A pressure reducing regulator s primary function is to match the flow of gas through the regulator to the demand for gas placed upon it whilst maintaining a sufficiently constant output pressure If the load flow decreases then the regulator flow must decrease as well If the load flow increases then the regulator flow must increase in order to keep the controlled pressure from decreasing due to a shortage of gas in the pressure system It is desirable that the controlled pressure does not vary greatly from the set point for a wide range of flow rates but it is also desirable that flow through the regulator is stable and the regulated pressure is not subject to excessive oscillation citation needed A pressure regulator includes a restricting element a loading element and a measuring element The restricting element is a valve that can provide a variable restriction to the flow such as a globe valve butterfly valve poppet valve etc The loading element is a part that can apply the needed force to the restricting element This loading can be provided by a weight a spring a piston actuator or the diaphragm actuator in combination with a spring The measuring element functions to determine when the inlet flow is equal to the outlet flow The diaphragm itself is often used as a measuring element it can serve as a combined element citation needed In the pictured single stage regulator a force balance is used on the diaphragm to control a poppet valve in order to regulate pressure With no inlet pressure the spring above the diaphragm pushes it down on the poppet valve holding it open Once inlet pressure is introduced the open poppet allows flow to the diaphragm and pressure in the upper chamber increases until the diaphragm is pushed upward against the spring causing the poppet to reduce flow finally stopping further increase of pressure By adjusting the top screw the downward pressure on the diaphragm can be increased requiring more pressure in the upper chamber to maintain equilibrium In this way the outlet pressure of the regulator is controlled citation needed F P i P o s P o S f displaystyle F P i P o s P o S f F diaphragm spring force displaystyle F text diaphragm spring force f poppet spring force displaystyle f text poppet spring force P i inlet pressure displaystyle P i text inlet pressure P o outlet pressure displaystyle P o text outlet pressure s poppet area displaystyle s text poppet area S diaphragm area displaystyle S text diaphragm area Single stage regulator Edit Single stage pressure regulator High pressure gas from the supply enters the regulator through the inlet port The inlet pressure gauge will indicate this pressure The gas then passes through the normally open pressure control valve orifice and the downstream pressure rises until the valve actuating diaphragm is deflected sufficiently to close the valve preventing any more gas from entering the low pressure side until the pressure drops again The outlet pressure gauge will indicate this pressure citation needed The outlet pressure on the diaphragm and the inlet pressure and poppet spring force on the upstream part of the valve hold the diaphragm poppet assembly in the closed position against the force of the diaphragm loading spring If the supply pressure falls the closing force due to supply pressure is reduced and downstream pressure will rise slightly to compensate Thus if the supply pressure falls the outlet pressure will increase provided the outlet pressure remains below the falling supply pressure This is the cause of end of tank dump where the supply is provided by a pressurized gas tank citation needed The operator can compensate for this effect by adjusting the spring load by turning the knob to restore outlet pressure to the desired level With a single stage regulator when the supply pressure gets low the lower inlet pressure causes the outlet pressure to climb If the diaphragm loading spring compression is not adjusted to compensate the poppet can remain open and allow the tank to rapidly dump its remaining contents citation needed Double stage regulator Edit Two stage pressure regulator Two stage regulators are two regulators in series in the same housing that operate to reduce the pressure progressively in two steps instead of one The first stage which is preset reduces the pressure of the supply gas to an intermediate stage gas at that pressure passes into the second stage The gas emerges from the second stage at a pressure working pressure set by user by adjusting the pressure control knob at the diaphragm loading spring Two stage regulators may have two safety valves so that if there is any excess pressure between stages due to a leak at the first stage valve seat the rising pressure will not overload the structure and cause an explosion citation needed An unbalanced single stage regulator may need frequent adjustment As the supply pressure falls the outlet pressure may change necessitating adjustment In the two stage regulator there is improved compensation for any drop in the supply pressure citation needed Applications EditPressure reducing regulators Edit Air compressors Edit Air compressors are used in industrial commercial and home workshop environments to perform an assortment of jobs including blowing things clean running air powered tools and inflating things like tires balls etc Regulators are often used to adjust the pressure coming out of an air receiver tank to match what is needed for the task Often when one large compressor is used to supply compressed air for multiple uses often referred to as shop air if built as a permanent installation of pipes throughout a building additional regulators will be used to ensure that each separate tool or function receives the pressure it needs This is important because some air tools or uses for compressed air require pressures that may cause damage to other tools or materials citation needed Aircraft Edit Pressure regulators are found in aircraft cabin pressurization canopy seal pressure control potable water systems and waveguide pressurization 3 Aerospace Edit Aerospace pressure regulators have applications in propulsion pressurant control for reaction control systems RCS and Attitude Control Systems ACS where high vibration large temperature extremes and corrosive fluids are present 4 Cooking Edit Pressurized vessels can be used to cook food much more rapidly than at atmospheric pressure as the higher pressure raises the boiling point of the contents All modern pressure cookers will have a pressure regulator valve and a pressure relief valve as a safety mechanism to prevent explosion in the event that the pressure regulator valve fails to adequately release pressure Some older models lack a safety release valve citation needed Most home cooking models are built to maintain a low and high pressure setting These settings are usually 7 to 15 pounds per square inch 0 48 to 1 03 bar Almost all home cooking units will employ a very simple single stage pressure regulator Older models will simply use a small weight on top of an opening that will be lifted by excessive pressure to allow excess steam to escape Newer models usually incorporate a spring loaded valve that lifts and allows pressure to escape as pressure in the vessel rises Some pressure cookers will have a quick release setting on the pressure regulator valve that will essentially lower the spring tension to allow the pressure to escape at a quick but still safe rate Commercial kitchens also use pressure cookers in some cases using oil based pressure cookers to quickly deep fry fast food Pressure vessels of this sort can also be used as autoclaves to sterilize small batches of equipment and in home canning operations citation needed Water pressure reduction Edit Pressure regulator for domestic water supply Outlet pressure is set with the blue handwheel and shown on the vertical scale A water pressure regulating valve limits inflow by dynamically changing the valve opening so that when less pressure is on the out side the valve opens up fully and too much pressure on the out side causes the valve to shut In a no pressure situation where water could flow backwards it won t be impeded A water pressure regulating valve does not function as a check valve They are used in applications where the water pressure is too high at the end of the line to avoid damage to appliances or pipes Welding and cutting Edit Oxy fuel welding and cutting processes require gases at specific pressures and regulators will generally be used to reduce the high pressures of storage cylinders to those usable for cutting and welding Oxygen and fuel gas regulators usually have two stages The first stage of the regulator releases the gas at a constant pressure from the cylinder despite the pressure in the cylinder becoming less as the gas is released The second stage of the regulator controls the pressure reduction from the intermediate pressure to low pressure The final flow rate may be adjusted at the torch The regulator assembly usually has two pressure gauges one indicating cylinder pressure the other indicating delivery pressure Inert gas shielded arc welding also uses gas stored at high pressure provided through a regulator There may be a flow gauge calibrated to the specific gas citation needed Propane LP Gas Edit All propane and LP Gas applications require the use of a regulator Because pressures in propane tanks can fluctuate significantly with temperature regulators must be present to deliver a steady pressure to downstream appliances These regulators normally compensate for tank pressures between 30 200 pounds per square inch 2 1 13 8 bar and commonly deliver 11 inches water column 0 4 pounds per square inch 28 mbar for residential applications and 35 inches of water column 1 3 pounds per square inch 90 mbar for industrial applications Propane regulators differ in size and shape delivery pressure and adjustability but are uniform in their purpose to deliver a constant outlet pressure for downstream requirements Common international settings for domestic LP Gas regulators are 28 mbar for butane and 37 mbar for propane Gas powered vehicles Edit All vehicular motors that run on compressed gas as a fuel internal combustion engine or fuel cell electric power train require a pressure regulator to reduce the stored gas CNG or Hydrogen pressure from 700 500 350 or 200 bar or 70 50 35 and 20 MPa to operating pressure citation needed Recreational vehicles Edit For recreational vehicles with plumbing a pressure regulator is required to reduce the pressure of an external water supply connected to the vehicle plumbing as the supply may be a much higher elevation than the campground and water pressure depends on the height of the water column Without a pressure regulator the intense pressure encountered at some campgrounds in mountainous areas may be enough to burst the camper s water pipes or unseat the plumbing joints causing flooding Pressure regulators for this purpose are typically sold as small screw on accessories that fit inline with the hoses used to connect an RV to the water supply which are almost always screw thread compatible with the common garden hose citation needed Breathing gas supply Edit Main articles Diving regulator and Self contained breathing apparatus Pressure regulators are used with Diving cylinders for Scuba diving The tank may contain pressures in excess of 3 000 pounds per square inch 210 bar which could cause a fatal barotrauma injury to a person breathing it directly A demand controlled regulator provides a flow of breathing gas at the ambient pressure which varies by depth in the water Pressure reducing regulators are also use to supply breathing gas to surface supplied divers 5 and people who use self contained breathing apparatus for rescue and hazmat work on land Supplementary oxygen for high altitude flight in unpressurised aircraft and medical gases are also dispensed through pressure reducing regulators from high pressure storage citation needed Mining Industry Edit As the pressure builds rapidly in relation to depth underground mining operations require a fairly complex water system with pressure reducing valves These devices must be installed at a certain distance interval usually 600 feet 180 m citation needed clarification needed Without such valves pipes would easily burst and pressure would be too great for equipment operation Natural Gas Industry Edit Pressure regulators are used extensively within the natural gas industry Natural gas is compressed to high pressures in order to be distributed throughout the country through large transmission pipelines The transmission pressure can be over 1 000 pounds per square inch 69 bar and must be reduced through various stages to a usable pressure for industrial commercial and residential applications There are three main pressure reduction locations in this distribution system The first reduction is located at the city gate whereas the transmission pressure is dropped to a distribution pressure to feed throughout the city This is also the location where the odorless natural gas is odorized with mercaptan The distribution pressure is further reduced at a district regulator station located at various points in the city to below 60 psig The final cut would occur at the end users location Generally the end user reduction is taken to low pressures ranging from 0 25 psig to 5 psig Some industrial applications can require a higher pressure citation needed Back pressure regulators Edit See also Back pressure regulator Maintain upstream pressure control in analytical or process systems 1 Protect sensitive equipment from overpressure damage 1 Reduce the pressure difference over a component which is not tolerant of large pressure differences 6 Gas sales lines 7 Production vessels e g Separators heater treaters or free water knockouts 7 Vent or flare lines 7 Hyperbaric chambers Edit Where the pressure drop on a built in breathing system exhaust system is too great typically in saturation systems a back pressure regulator may be used to reduce the exhaust pressure drop to a safer and more manageable pressure 6 8 Reclaim diving helmets Edit The depth at which most heliox breathing mixtures are used in surface supplied diving is generally at least 5 bar above surface atmospheric pressure and the exhaust gas from the diver must pass through a reclaim valve which is a demand controlled back pressure valve activated by the increase in pressure in the diver s helmet caused by diver exhalation 9 10 The reclaim gas hose which carries the exhaled gas back to the surface for recycling must not be at too great a pressure difference from the ambient pressure at the diver An additional back pressure regulator in this line allows finer setting of the reclaim valve for lower work of breathing at variable depths 11 See also EditBuilt in breathing system System for supply of breathing gas on demand within a confined space Control valve Flow control device Negative feedback Control system used to reduce excursions from the desired valueReferences Edit a b c d Pressure Regulator vs Backpressure Regulator When to use one or the other and when to use both plastomatic com Retrieved 19 March 2020 a b Definition of Back Pressure Regulator What do back pressure regulators do www equilibar com Retrieved 19 March 2020 gt Aircraft Pressure Regulators www valcor com Retrieved 19 March 2020 Aerospace Pressure Regulators www valcor com Retrieved 19 March 2020 NOAA Diving Program U S 28 February 2001 Joiner James T ed NOAA Diving Manual Diving for Science and Technology 4th ed Silver Spring Maryland National Oceanic and Atmospheric Administration Office of Oceanic and Atmospheric Research National Undersea Research Program ISBN 978 0 941332 70 5 CD ROM prepared and distributed by the National Technical Information Service NTIS in partnership with NOAA and Best Publishing Company a b A Lightweight and Extremely Robust Built In Breathing System for Hyperbaric Chambers PDF Aberdeen Scotland C Tecnics Ltd Archived from the original PDF on 25 September 2018 Retrieved 25 September 2018 a b c Jeff Port 21 May 2019 Back Pressure Regulator vs Pressure Reducing Regulator What s the Difference blog kimray com Retrieved 19 March 2020 Divex back pressure regulator Retrieved 19 March 2020 Gas reclaim back pressure regulator Retrieved 19 March 2020 via patents google com Helmet gas reclaim valve www subspec it Retrieved 19 March 2020 Reclaim Basic Set Up PDF www subseasa com Retrieved 10 March 2020 External links EditPressure Animations Wikimedia Commons has media related to Pressure regulators Retrieved from https en wikipedia org w index php title Pressure regulator amp oldid 1118773985, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.