fbpx
Wikipedia

Parshall flume

The Parshall flume is an open channel flow metering device that was developed to measure the flow of surface waters and irrigation flows. The Parshall flume is a fixed hydraulic structure. It is used to measure volumetric flow rate in industrial discharges, municipal sewer lines, and influent/effluent flows in wastewater treatment plants. The Parshall flume accelerates flow through a contraction of both the parallel sidewalls and a drop in the floor at the flume throat. Under free-flow conditions the depth of water at specified location upstream of the flume throat can be converted to a rate of flow. Some states specify the use of Parshall flumes, by law, for certain situations (commonly water rights).[1]

The design of the Parshall flume is standardized under ASTM D1941, ISO 9826:1992, and JIS B7553-1993. The flumes are not patented and the discharge tables are not copyright protected.

A total of 22 standard sizes of Parshall flumes have been developed, covering flow ranges from 0.005–3,280 cfs (0.1416–92,890 L/s).[2]

Submergence transitions for Parshall flumes range from 50% (1–3 in sizes) to 80% (10–50 ft sizes),[3] beyond which point level measurements must be taken at both the primary and secondary points of measurement and a submergence correction must be applied to the flow equations. The secondary point of measurement (Hb) for a Parshall flume is located in the throat, measuring Hb can be difficult as flow in the throat of the flume is turbulent and prone to fluctuations in the water level. 90% is viewed as the upper limit for which corrections for submerged flow are practical.[4]

Parshall flumes (right) alongside other types of flow meters
Diagram of a Parshall flume, showing free-flow and submerged flow operating regimes

A modified version of the Venturi flume is the Parshall flume. Named after its creator, Dr. Ralph L. Parshall of the U.S. Soil Conservation Service, the Parshall flume is a fixed hydraulic structure used in measuring volumetric flow rate in surface water, wastewater treatment plant, and industrial discharge applications. The Parshall flume accelerates flow through a contraction of both the parallel sidewalls and a drop in the floor at the flume throat. Under free-flow conditions the depth of water at specified location upstream of the flume throat can be converted to a rate of flow.

The free-flow discharge can be summarized as

Where

  • Q is flow rate
  • C is the free-flow coefficient for the flume
  • H is the head at the primary point of measurement
  • n varies with flume size (e.g. 1.55 for a 1-inch flume)

When the downstream depth is high enough that the transition to subcritical flow advances upstream into the throat and the hydraulic jump disappears, the flume is operating in a "submerged flow" regime, and the discharge is instead given by

Where is the "submergence correction", and is found using pre-determined tables for a particular flume geometry.

The Parshall flume is an empirically calibrated device, so interpolation between listed sizes is not an accurate way to make intermediate size flumes. The flumes are not scale models of each other. 22 standard sizes of Parshall flumes have been developed, covering flow ranges from 0.005 cfs [0.1416 l/s] to 3,280 cfs [92,890 l/s].[5]

Submergence transitions for Parshall flumes range from 50% (1–3 in sizes) to 80% (10–50 ft sizes),[6] beyond which point level measurements must be taken at both the primary and secondary points of measurement and a submergence correction must be applied to the flow equations.

Under laboratory conditions Parshall flumes can be expected to exhibit accuracies to within ±2%, although field conditions make accuracies better than 5% doubtful.

Not all Parshall flumes have the energy-recovering divergence section. These flumes, called Montana flumes, or short-section Parshall flumes, must instead have a free-spilling discharge at all expected flow rates, which increases the drop along the whole flume system. The measurement calculations are the same as for free-flow in a standard Parshall flume, but submerged flow cannot be adjusted for.[7]

Differences between the Venturi and Parshall flume include: reduction of the inlet converging angle, lengthening the throat section, reduction of the discharge divergence angle, and introducing a drop through the throat (and subsequent partial recovery in the discharge section).[8]

Drawbacks

  • Parshall flumes require a drop in elevation through the flume. To accommodate the drop in an existing channel either the flume must be raised above the channel floor (raising the upstream water level) or the downstream channel must be modified.
  • As with weirs, flumes can also have an effect on local fauna. Some species or certain life stages of the same species may be blocked by flumes due to relatively slow swim speeds or behavioral characteristics.
  • In earthen channels, upstream bypass and downstream scour may occur.
  • Parshall flumes below 3-inches in size should not be used on unscreened sanitary flows.

Standards

  • ASTM D1941 – 91(2013) Standard Test Method for Open Channel Flow Measurement of Water with the Parshall Flume
  • ISO 9826:1992 Measurement of Liquid Flow in Open Channels – Parshall and SANIIRI Flumes

A venturi flume is similar to the Parshall flume, without the contoured base, but the cross section is usually rectangular, the inlet shorter, and there is a general taper on the outlet similar to the venturi meter.[9] Because of their size, it is usual for these meters to be open to their surroundings just like a river or stream and therefore this type of measurement is referred to as open-channel flow measurement. Parshall flumes are much more efficient than standard flumes and generate a standard wave to effect a measurement.

A good example can be found via google earth: 50°58'41.34"N, 5°51'36.81"E, eye altitude 200 m. This is in the Geleenbeek, near Geleen in the Netherlands.

Development

Beginning in 1915, Dr. Ralph Parshall of the U.S. Soil Conservation Service altered the subcritical Venturi flume to include a drop in elevation through the throat of the flume. This created a transition from subcritical flow conditions to supercritical flow conditions through the throat of the flume.

Modifications to the Venturi flume that Parshall made include:[10]

  • Decreasing the angle of convergence of the inlet walls
  • Lengthening the throat
  • Decreasing the angle of divergence of the outlet wall
  • Introducing a drop through the throat of the flume

In 1930, the improved flume was named the Parshall Measuring Flume by the Irrigation Committee of the American Society of Civil Engineers (ASCE) in recognition of Parshall's accomplishments. Parshall was additionally honored as a Life Member of the ASCE.[11]

Function

 
Diagram of a Parshall flume showing free flow and submerged flow operation (with optional inlet / outlet wing walls and stilling wells)

The Parshall Flume acts essentially as a constriction, a downward step, and then an expansion: the upstream section is uniformly converging and flat, the throat is a short parallel section that slopes downward, and the downstream section is uniformly diverging and slopes upward to an ending elevation that is less than the upstream starting elevation. The width of the throat determines the flume size; 22 standardized sizes have been developed, ranging from 1 in to 50 ft (0.005 ft3/s to 3,280 ft3/s).

There are two conditions of flow that can occur in a Parshall flume: free flow and submerged flow. When free flow conditions exist, the user only needs to collect one head measurement (Ha, the primary point of measurement) to determine the discharge. For submerged flow a secondary head measurement (Hb) is required to determine the flume is submerged and the degree of submergence.

The primary point of measurement (Ha) is located in the inlet of the flume, two-thirds of the length of the converging section from the flume crest. The secondary point of measurement (Hb) is located in the throat of the flume.

A hydraulic jump occurs downstream of the flume for free flow conditions. As the flume becomes submerged, the hydraulic jump diminishes and ultimately disappears as the downstream conditions increasingly restrict the flow out of the flume.

Animation of a Parshall flume

The free-flow discharge can be summarized as

 

where

  • Q is flow rate
  • C is the free-flow coefficient for the flume
  • Ha is the head at the primary point of measurement
  • n varies with flume size (e.g. 1.55 for a 1-inch flume)

Derivation

A Parshall Flume relies on the conservation of energy principle. The sum of the kinetic and potential energy at a given point must be equal to the energy at any other point along the stream. The total energy or head must be equal.

Using the equations, we will solve for Q.

 
 
 

Where E1 is the energy at Ha, E2 at the flume crest, and E3 at Hb respectively.

Since E2 is located at the flume crest where there is a steep drop, critical flow conditions occur.

 

Rearranging and substituting in the above equations, we get

 

Or

 

Since we know that Q = v⋅y⋅b and v = gyc at critical depth, we can use these relationships to solve for the discharge.

 

Broken further down, we realize that

 

And

 

Since this is measured upstream, where flow is sub-critical, it can be stated that y1 ≫ v2/2g

Therefore, for a rough approximation we can say

 

This equation simplifies to:

  • In ft3/s:  
  • In m3/s:  

These final two equations are very similar to the Q = CHan equations that are used for Parshall flumes. In fact when looking at the flume tables, n has a value equal to or slightly greater than 1.5, while the value of C is larger than (3.088 b2) but still in a rough estimation. The derived equations above will always underestimate actual flow since both the derived C and n values are lower than their respective chart values.

For the Parshall flume equation used to calculate the flow rate, both empirical values C and n are known constants (with various values for each Parshall flume size) leaving Ha (depth upstream) as the only variable needing to be measured. Likewise, in the energy conservation equation, y1 (or the depth of flow) is needed.

Free vs. submerged flow

Free flow: When there is no “back water” to restrict flow through a flume. Only the upstream depth needs to be measured to calculate the flow rate. A free flow also induces a hydraulic jump downstream of the flume.

Submerged flow: When the water surface downstream of the flume is high enough to restrict flow through a flume, submerged flume conditions exist. A backwater buildup effect occurs in a submerged flume. For a flow calculation a depth measurement both upstream and downstream is needed.

Although commonly thought of as occurring at higher flow rates, submerged flow can exist at any flow level as it is a function of downstream conditions. In natural stream applications, submerged flow is frequently the result of vegetative growth on the downstream channel banks, sedimentation, or subsidence of the flume.

Free flow E-Y diagram depiction

Illustrated above is a unitless E – Y diagram and how Energy and depth of flow changes throughout a Parshall Flume. The two blue lines represent the q values, q1 for the flow before the constriction, and q2 representing the value at the constriction (q = Q/b = ft2/s, or flow over width in a rectangular channel). When a constriction (decrease in width) happens Between E1 and E2, the q value changed (and becomes the new critical depth), while the energy remains the same. Then the flume experiences a downward step which results in a gain in energy. This gain in energy is equal to the size of the step (or Δz). From this the principles of conservation of energy are used to develop a set of calculations to predict the flow rate.

Parshall flume discharge values

For free flow, the equation to determine the flow rate is simply Q = CHan where:

  • Q is flow rate (ft3/s)
  • C is the free-flow coefficient for the flume (see Table 1 below)
  • Ha is the head at the primary point of measurement (ft)

(See Figure 1 above)

  • n varies with flume size (see Table 1 below)

Parshall flume discharge table for free flow conditions:[12]

Table 1
Throat width Coefficient (C) Exponent (n)
1 in 0.338 1.55
2 in 0.676 1.55
3 in 0.992 1.55
6 in 2.06 1.58
9 in 3.07 1.53
1 ft 3.95 1.55
1.5 ft 6.00 1.54
2 ft 8.00 1.55
3 ft 12.00 1.57
4 ft 16.00 1.58
5 ft 20.00 1.59
6 ft 24.00 1.59
7 ft 28.00 1.60
8 ft 32.00 1.61
10 ft 39.38 1.60
12 ft 46.75 1.60
15 ft 57.81 1.60
20 ft 76.25 1.60
25 ft 94.69 1.60
30 ft 113.13 1.60
40 ft 150.00 1.60
50 ft 186.88 1.60

For submerged flow, a depth of flow needs to be taken upstream (Ha) and downstream (Hb). See locations of Ha and Hb in Figure 1.[12]

Flume size St
1–3 in 0.5
6–9 in 0.6
1–8 ft 0.7
10–50 ft 0.8

If Hb/Ha is greater or equal to St then it is a submerged flow. If there is submerged flow, adjustments need to be made in order for the Parshall Flume to work properly.

The discharge (Q) can be found using the following equations and table:

  • Qnet = Qfree flow – Qcorrection
  • Qcorrection = M (0.000132 Ha2.123 e9.284 St)

where:

  • S, Hb/Ha
  • M, multiplying factor

(Note: All various Q values are in ft3/s, Ha is in feet, and M varies in units)

Table 3[12]
Size of flume, Ft Multiplying factor, M
1 1
1.5 1.4
2 1.8
3 2.4
4 3.1
5 3.7
6 4.3
7 4.9
8 5.4

Example

Parshall Flume Free Flow Example Problem:

Using the Parshall flume free flow equation, determine the discharge of a 72-inch flume with a depth, Ha of 3 feet.

From Table 1: Throat width = 72 in = 6 ft, C = 24, and n = 1.59.

Q = 24 Ha1.59 for a 72-inch Parshall flume

So, if there is a depth of 3 feet, the flow rate is ≈ 140 ft3/s

Approximate the discharge using the derived discharge equation shown above (Equation 5). This equation was derived using the principles of specific energy and is only to serve as an estimate for the actual discharge of the Parshall flume. Again, equations 5 and 6 will always underestimate the actual flow since both the derived C and n values are lower than their respective empirically derived chart values.

Q = (6 ft) × (3.088) × (3 ft) × 1.5 = 96 ft3/s

Parshall flume submerged flow example problem:

Using the Parshall flume flow equations and Tables 1-3, determine the flow type (free flow or submerged flow) and discharge for a 36-inch flume with an upstream depth, Ha of 1.5 ft and a downstream depth, Hb of 1.4 ft. For reference of locations Ha and Hb, refer to Figure 1.

From Table 2, the Parshall Flume submergence transition (St) for a 36-inch = 3 feet flume is 0.7. Since Hb/Ha is greater than or equal to 0.7, it is a submerged flow.

Qnet = Qfree flow – Qcorrection
Q = CHan

From Table 1: Throat width = 36 in = 3 ft, C = 12, and n = 1.57.

Qfree flow = 12 × (1.5 ft) × 1.57 = 22.68 ft3/s
Qcorrection = M × 0.000132 × Ha × 2.123×109.284 × S

Where S = Hb/Ha = 1.4 ft/1.5 ft = 0.93

From Table 3, M = 2.4 for a flume size of 3 ft

Qcorrection = 2.4 × (0.000132) × (1.5 ft) × (2.123×109.284) × (0.93) = 4.21 ft3/s
Qnet = 22.68 ft3/s – 4.21 ft3/s = 18.5 ft3/s

Construction

A wide variety of materials are used to make Parshall flumes, including:[13]

  • Fiberglass[14] (wastewater applications due to its corrosion resistance)
  • Stainless steel[15] (applications involving high temperatures / corrosive flow streams)
  • Galvanized steel[16] (water rights / irrigation)
  • Concrete (large Parshall throat widths 144 in [3.66 m] and above)
  • Aluminum[17] (portable applications)
  • Wood (temporary flow measurement)
  • Plastic (PVC or polycarbonate / Lexan) (teaching/laboratory investigation)

Smaller Parshall flumes tend to be fabricated from fiberglass and galvanized steel (depending upon the application), while larger Parshall flumes tend to fabricated from fiberglass (sizes up to 144 in) or concrete (160–600 in).[18]

By the 1960s, several different companies began to commercially offer Parshall flumes. These manufacturers have typically produce flumes from one type of material only (typically glass-reinforce plastic or steel), although currently a few, offer Parshall flumes in a variety of materials.

Installation

Dr. Parshall's initial focus was for the use of his namesake flume to measure flows in irrigation channels and other surface waters.

Over time, however, the Parshall flume has proven to be applicable to a wide variety of open channel flows including:

  • Irrigation channels and ditches
  • Furrows
  • Surface waters (swales, creeks, streams, and rivers)
  • Elevated, above grade piped flows
  • Below grade piped flows (concrete vaults / manholes incorporated into Packaged Metering Manholes)

Drawbacks

  • Parshall flumes require a drop in elevation through the flume. To accommodate the drop in an existing channel either the flume must be raised above the channel floor (raising the upstream water level) or the downstream channel must be modified.
  • As with weirs, flumes can also have an effect on local fauna. Some species or certain life stages of the same species may be blocked by flumes due to relatively slow swim speeds or behavioral characteristics.
  • In earthen channels, upstream bypass and downstream scour may occur. Armoring of the upstream and downstream channels is recommended.
  • Parshall flumes below 3 inches in size should not be used on unscreened sanitary flows, due to the likelihood of clogging.[19]
  • The Parshall flume is an empirical device. Interpolation between sizes is not an accurate method of developing intermediate size Parshall flumes as the flumes are not scale models of each other.[20][21][22] The 30-inch [76.2 cm] and 42-inch [106.7 cm] sizes are examples of intermediate sizes of Parshall flumes that have crept into the marketplace without the backing of published research into their sizing and flow rates.[23]

Variations

Two variations of the Parshall flume have been developed over time: the Montana flume and the Short Section (USGS / Portable) Parshall flume.[24]

Montana flume

The Montana flume omits the throat and discharge sections of the Parshall.[25] By omitting these sections, the flume is shortened by more than half, while retaining the free-flow characteristics of the same-size Parshall. With the deletion of the throat and discharge section, the Montana flume has little resistance to submersion and, like the H flume, should be used where free-spilling discharge is present under all flow conditions. The Montana flume is described in US Bureau of Reclamation's Water Measurement Manual[26] and two technical standards MT199127AG[27] and MT199128AG[28] by Montana State University (note that Montana State University has currently withdrawn both standards for updating/review).

Short Section (USGS Portable) Parshall flume

The short-section Parshall (sometimes referred to as a USGS or Portable Parshall) omits the discharge section of the flume. Originally designed by Troxell and Taylor in 1931 and published under "Venturi Flume" as a memorandum from the office of the Ground Water Branch, USGS, the design was again brought to the attention of potential users in Taylors' paper "Portable Venturi Flume for Measuring Small Flows in 1954.[29] This modification - supplied by the USGS Hydrologic Instrumentation Facility - is available in two sizes: the original 3" and the recently added 6".[30]

Kilpatrick notes that the discharge for this modification of the Parshall flume is slightly greater than for a standard Parshall flume of the same size.[31] This has been attributed to potential manufacturing tolerance variations rather than the actual operation of the flume itself and users are cautioned to verify the flume's dimensions before proceeding with data collection. As with any Parshall flume, flumes varying from the standard dimensions flumes should be individual rated.

When used for stream gauging, aluminum is the typical material of construction - primarily due to its light weight.

References

  1. ^ . Usbr.gov. Archived from the original on 2003-06-14. Retrieved 2013-04-15.
  2. ^ "Parshall Flumes for Flow Measurement". Openchannelflow. Retrieved 2013-04-15.
  3. ^ "Flow Characteristics of Parshall Flumes". Openchannelflow. Retrieved 2013-04-15.
  4. ^ "Parshall Flume Submergence". Openchannelflow. Retrieved 2013-04-15.
  5. ^ "Parshall Flumes for Flow Measurement". openchannelflow.com. Retrieved 2015-04-21.
  6. ^ "Flow Characteristics of Parshall Flumes". openchannelflow.com. Retrieved 2015-04-21.
  7. ^ "Montana Flumes - What are they?". openchannelflow.com. Retrieved 2015-04-21.
  8. ^ "The Improved Venturi Flume" (PDF). digitool.library.colostate.edu. Retrieved 2015-04-21.[permanent dead link]
  9. ^ de Sa, D.O. (2001). Instrumentation Fundamentals for Process Control. Taylor & Francis. p. 9. ISBN 9781560329015. Retrieved 2015-04-21.
  10. ^ Parshall, Ralph (1928). The Improved Venturi Flume (PDF). Fort Collins, CO: Colorado Agricultural College.
  11. ^ "Guide to the Ralph L. Parshall Collection".
  12. ^ a b c . Archived from the original on 2013-04-10. Retrieved 2013-04-15.
  13. ^ "Field measurement of soil erosion and runoff - Chapter 4 Streamflow". Fao.org. Retrieved 2013-04-15.
  14. ^ "Fiberglass - FRP - Parshall Flumes". www.openchannelflow.com. Retrieved 2020-01-07.
  15. ^ "Stainless Steel Parshall Flumes". www.openchannelflow.com. Retrieved 2020-01-07.
  16. ^ "Galvanized Steel Parshall Flumes". www.openchannelflow.com. Retrieved 2020-01-07.
  17. ^ "Aluminum Parshall Flumes". www.openchannelflow.com. Retrieved 2020-01-07.
  18. ^ "Large Parshall Flumes". www.openchannelflow.com. Retrieved 2020-01-07.
  19. ^ "Don't Get Stuck: Sanitary Flows in Flumes".
  20. ^ "Water Measurement Manual, Chapter 8, Section 10".
  21. ^ "Parshall Flumes".
  22. ^ "Recommended Practice for the Use of Parshall Flumes and Palmer-Bowlus Flumes in Wastewater Treatment Plants". EPA600/2-84-186. November 1984: 5. {{cite journal}}: Cite journal requires |journal= (help)
  23. ^ "Non-Standard Parshall Flume Sizes".
  24. ^ "USGS Portable Parshall Flumes".
  25. ^ "Montana Flume Dimensions".
  26. ^ . Archived from the original on 2014-10-01. Retrieved 2013-03-26.
  27. ^ "MT199127AG". Archived from the original on 2014-06-01.
  28. ^ "MT199128AG". Archived from the original on 2014-06-01.
  29. ^ http://pubs.usgs.gov/of/1963/0063/report.pdf[bare URL PDF]
  30. ^ "USGS Hydrologic Instrumentation Facility Instrument Project: Six inch modified Parshall Flume (Portable)". Water.usgs.gov. Retrieved 2016-09-03.
  31. ^ Kilpatrick; Schneider. "Techniques of Water-Resources Investigations" (3, Chapter A14). {{cite journal}}: Cite journal requires |journal= (help)

External links

  • Pictures of fiberglass, galvanized and stainless steel Parshall flumes

Further reading

  • ASTM D1941 – 91(2013) Standard Test Method for Open Channel Flow Measurement of Water with the Parshall Flume
  • ISO 9826:1992 Measurement of Liquid Flow in Open Channels – Parshall and SANIIRI Flumes
  • JIS B7553-1993 Parshall Flume Type Flowmeters
  • Bos, Marinus (1989). Discharge Measurement Structures. Third edition revised. Publication 20. Oxford, United Kingdom: International Institute for Land Reclamation and Improvement. ISBN 978-9070754150.
  • Grant, Doug; Dawson, Brian (2001). ISCO Open Channel Flow Measurement Handbook (5th ed.). ISBN 978-0962275722.

parshall, flume, this, article, multiple, issues, please, help, improve, discuss, these, issues, talk, page, learn, when, remove, these, template, messages, this, article, needs, additional, citations, verification, please, help, improve, this, article, adding. This article has multiple issues Please help improve it or discuss these issues on the talk page Learn how and when to remove these template messages This article needs additional citations for verification Please help improve this article by adding citations to reliable sources Unsourced material may be challenged and removed Find sources Parshall flume news newspapers books scholar JSTOR April 2013 Learn how and when to remove this template message This article may be too technical for most readers to understand Please help improve it to make it understandable to non experts without removing the technical details February 2022 Learn how and when to remove this template message This article s tone or style may not reflect the encyclopedic tone used on Wikipedia See Wikipedia s guide to writing better articles for suggestions February 2022 Learn how and when to remove this template message Learn how and when to remove this template message The Parshall flume is an open channel flow metering device that was developed to measure the flow of surface waters and irrigation flows The Parshall flume is a fixed hydraulic structure It is used to measure volumetric flow rate in industrial discharges municipal sewer lines and influent effluent flows in wastewater treatment plants The Parshall flume accelerates flow through a contraction of both the parallel sidewalls and a drop in the floor at the flume throat Under free flow conditions the depth of water at specified location upstream of the flume throat can be converted to a rate of flow Some states specify the use of Parshall flumes by law for certain situations commonly water rights 1 The design of the Parshall flume is standardized under ASTM D1941 ISO 9826 1992 and JIS B7553 1993 The flumes are not patented and the discharge tables are not copyright protected A total of 22 standard sizes of Parshall flumes have been developed covering flow ranges from 0 005 3 280 cfs 0 1416 92 890 L s 2 Submergence transitions for Parshall flumes range from 50 1 3 in sizes to 80 10 50 ft sizes 3 beyond which point level measurements must be taken at both the primary and secondary points of measurement and a submergence correction must be applied to the flow equations The secondary point of measurement Hb for a Parshall flume is located in the throat measuring Hb can be difficult as flow in the throat of the flume is turbulent and prone to fluctuations in the water level 90 is viewed as the upper limit for which corrections for submerged flow are practical 4 Parshall flumes right alongside other types of flow meters Diagram of a Parshall flume showing free flow and submerged flow operating regimes A modified version of the Venturi flume is the Parshall flume Named after its creator Dr Ralph L Parshall of the U S Soil Conservation Service the Parshall flume is a fixed hydraulic structure used in measuring volumetric flow rate in surface water wastewater treatment plant and industrial discharge applications The Parshall flume accelerates flow through a contraction of both the parallel sidewalls and a drop in the floor at the flume throat Under free flow conditions the depth of water at specified location upstream of the flume throat can be converted to a rate of flow The free flow discharge can be summarized as Q C H n displaystyle Q CH n Where Q is flow rate C is the free flow coefficient for the flume H is the head at the primary point of measurement n varies with flume size e g 1 55 for a 1 inch flume When the downstream depth is high enough that the transition to subcritical flow advances upstream into the throat and the hydraulic jump disappears the flume is operating in a submerged flow regime and the discharge is instead given by Q C H n Q E displaystyle Q CH n Q E Where Q E displaystyle Q E is the submergence correction and is found using pre determined tables for a particular flume geometry The Parshall flume is an empirically calibrated device so interpolation between listed sizes is not an accurate way to make intermediate size flumes The flumes are not scale models of each other 22 standard sizes of Parshall flumes have been developed covering flow ranges from 0 005 cfs 0 1416 l s to 3 280 cfs 92 890 l s 5 Submergence transitions for Parshall flumes range from 50 1 3 in sizes to 80 10 50 ft sizes 6 beyond which point level measurements must be taken at both the primary and secondary points of measurement and a submergence correction must be applied to the flow equations Under laboratory conditions Parshall flumes can be expected to exhibit accuracies to within 2 although field conditions make accuracies better than 5 doubtful Not all Parshall flumes have the energy recovering divergence section These flumes called Montana flumes or short section Parshall flumes must instead have a free spilling discharge at all expected flow rates which increases the drop along the whole flume system The measurement calculations are the same as for free flow in a standard Parshall flume but submerged flow cannot be adjusted for 7 Differences between the Venturi and Parshall flume include reduction of the inlet converging angle lengthening the throat section reduction of the discharge divergence angle and introducing a drop through the throat and subsequent partial recovery in the discharge section 8 Contents 1 Drawbacks 2 Standards 3 Development 4 Function 5 Derivation 6 Free vs submerged flow 7 Free flow E Y diagram depiction 8 Parshall flume discharge values 9 Example 10 Construction 11 Installation 12 Drawbacks 13 Variations 13 1 Montana flume 13 2 Short Section USGS Portable Parshall flume 14 References 15 External links 16 Further readingDrawbacks EditParshall flumes require a drop in elevation through the flume To accommodate the drop in an existing channel either the flume must be raised above the channel floor raising the upstream water level or the downstream channel must be modified As with weirs flumes can also have an effect on local fauna Some species or certain life stages of the same species may be blocked by flumes due to relatively slow swim speeds or behavioral characteristics In earthen channels upstream bypass and downstream scour may occur Parshall flumes below 3 inches in size should not be used on unscreened sanitary flows Standards EditASTM D1941 91 2013 Standard Test Method for Open Channel Flow Measurement of Water with the Parshall Flume ISO 9826 1992 Measurement of Liquid Flow in Open Channels Parshall and SANIIRI FlumesA venturi flume is similar to the Parshall flume without the contoured base but the cross section is usually rectangular the inlet shorter and there is a general taper on the outlet similar to the venturi meter 9 Because of their size it is usual for these meters to be open to their surroundings just like a river or stream and therefore this type of measurement is referred to as open channel flow measurement Parshall flumes are much more efficient than standard flumes and generate a standard wave to effect a measurement A good example can be found via google earth 50 58 41 34 N 5 51 36 81 E eye altitude 200 m This is in the Geleenbeek near Geleen in the Netherlands Development EditBeginning in 1915 Dr Ralph Parshall of the U S Soil Conservation Service altered the subcritical Venturi flume to include a drop in elevation through the throat of the flume This created a transition from subcritical flow conditions to supercritical flow conditions through the throat of the flume Modifications to the Venturi flume that Parshall made include 10 Decreasing the angle of convergence of the inlet walls Lengthening the throat Decreasing the angle of divergence of the outlet wall Introducing a drop through the throat of the flumeIn 1930 the improved flume was named the Parshall Measuring Flume by the Irrigation Committee of the American Society of Civil Engineers ASCE in recognition of Parshall s accomplishments Parshall was additionally honored as a Life Member of the ASCE 11 Function Edit Diagram of a Parshall flume showing free flow and submerged flow operation with optional inlet outlet wing walls and stilling wells The Parshall Flume acts essentially as a constriction a downward step and then an expansion the upstream section is uniformly converging and flat the throat is a short parallel section that slopes downward and the downstream section is uniformly diverging and slopes upward to an ending elevation that is less than the upstream starting elevation The width of the throat determines the flume size 22 standardized sizes have been developed ranging from 1 in to 50 ft 0 005 ft3 s to 3 280 ft3 s There are two conditions of flow that can occur in a Parshall flume free flow and submerged flow When free flow conditions exist the user only needs to collect one head measurement Ha the primary point of measurement to determine the discharge For submerged flow a secondary head measurement Hb is required to determine the flume is submerged and the degree of submergence The primary point of measurement Ha is located in the inlet of the flume two thirds of the length of the converging section from the flume crest The secondary point of measurement Hb is located in the throat of the flume A hydraulic jump occurs downstream of the flume for free flow conditions As the flume becomes submerged the hydraulic jump diminishes and ultimately disappears as the downstream conditions increasingly restrict the flow out of the flume source source source source source source source source source source source source source source Animation of a Parshall flume The free flow discharge can be summarized as Q C H a n displaystyle Q CH a n where Q is flow rate C is the free flow coefficient for the flume Ha is the head at the primary point of measurement n varies with flume size e g 1 55 for a 1 inch flume Derivation EditA Parshall Flume relies on the conservation of energy principle The sum of the kinetic and potential energy at a given point must be equal to the energy at any other point along the stream The total energy or head must be equal Using the equations we will solve for Q E y q 2 2 g y 2 displaystyle E y frac q 2 2gy 2 q Q b displaystyle q frac Q b E 1 D z E 2 D z E 3 displaystyle E 1 Delta z E 2 Delta z E 3 Where E1 is the energy at Ha E2 at the flume crest and E3 at Hb respectively Since E2 is located at the flume crest where there is a steep drop critical flow conditions occur E c 3 2 q 2 g 1 3 3 2 y c displaystyle E c frac 3 2 left frac q 2 g right frac 1 3 frac 3 2 y c Rearranging and substituting in the above equations we get y 1 Q b 1 2 2 g y 1 2 3 2 y c displaystyle y 1 frac left frac Q b 1 right 2 2gy 1 2 frac 3 2 y c Or 2 3 y 1 Q b 1 2 2 g y 1 2 y c displaystyle frac 2 3 left y 1 frac left frac Q b 1 right 2 2gy 1 2 right y c Since we know that Q v y b and v gyc at critical depth we can use these relationships to solve for the discharge Q b 2 g 2 3 y 1 Q b 1 2 2 g y 1 2 3 2 displaystyle Q b 2 sqrt g left frac 2 3 left y 1 frac left frac Q b 1 right 2 2gy 1 2 right right frac 3 2 Broken further down we realize that Q b 1 2 2 g y 1 2 v 2 2 g displaystyle frac left frac Q b 1 right 2 2gy 1 2 frac v 2 2g And E 1 y 1 v 2 2 g displaystyle E 1 y 1 frac v 2 2g Since this is measured upstream where flow is sub critical it can be stated that y1 v2 2gTherefore for a rough approximation we can say Q b 2 g 2 3 y 1 3 2 displaystyle Q approx b 2 sqrt g left frac 2 3 y 1 right frac 3 2 This equation simplifies to In ft3 s Q 3 088 b 2 y 1 5 displaystyle Q approx 3 088 b 2 y 1 5 In m3 s Q 1 704 b 2 y 1 5 displaystyle Q approx 1 704 b 2 y 1 5 These final two equations are very similar to the Q CHan equations that are used for Parshall flumes In fact when looking at the flume tables n has a value equal to or slightly greater than 1 5 while the value of C is larger than 3 088 b2 but still in a rough estimation The derived equations above will always underestimate actual flow since both the derived C and n values are lower than their respective chart values For the Parshall flume equation used to calculate the flow rate both empirical values C and n are known constants with various values for each Parshall flume size leaving Ha depth upstream as the only variable needing to be measured Likewise in the energy conservation equation y1 or the depth of flow is needed Free vs submerged flow EditFree flow When there is no back water to restrict flow through a flume Only the upstream depth needs to be measured to calculate the flow rate A free flow also induces a hydraulic jump downstream of the flume Submerged flow When the water surface downstream of the flume is high enough to restrict flow through a flume submerged flume conditions exist A backwater buildup effect occurs in a submerged flume For a flow calculation a depth measurement both upstream and downstream is needed Although commonly thought of as occurring at higher flow rates submerged flow can exist at any flow level as it is a function of downstream conditions In natural stream applications submerged flow is frequently the result of vegetative growth on the downstream channel banks sedimentation or subsidence of the flume Free flow E Y diagram depiction EditIllustrated above is a unitless E Y diagram and how Energy and depth of flow changes throughout a Parshall Flume The two blue lines represent the q values q1 for the flow before the constriction and q2 representing the value at the constriction q Q b ft2 s or flow over width in a rectangular channel When a constriction decrease in width happens Between E1 and E2 the q value changed and becomes the new critical depth while the energy remains the same Then the flume experiences a downward step which results in a gain in energy This gain in energy is equal to the size of the step or Dz From this the principles of conservation of energy are used to develop a set of calculations to predict the flow rate Parshall flume discharge values EditFor free flow the equation to determine the flow rate is simply Q CHan where Q is flow rate ft3 s C is the free flow coefficient for the flume see Table 1 below Ha is the head at the primary point of measurement ft See Figure 1 above n varies with flume size see Table 1 below Parshall flume discharge table for free flow conditions 12 Table 1 Throat width Coefficient C Exponent n 1 in 0 338 1 552 in 0 676 1 553 in 0 992 1 556 in 2 06 1 589 in 3 07 1 531 ft 3 95 1 551 5 ft 6 00 1 542 ft 8 00 1 553 ft 12 00 1 574 ft 16 00 1 585 ft 20 00 1 596 ft 24 00 1 597 ft 28 00 1 608 ft 32 00 1 6110 ft 39 38 1 6012 ft 46 75 1 6015 ft 57 81 1 6020 ft 76 25 1 6025 ft 94 69 1 6030 ft 113 13 1 6040 ft 150 00 1 6050 ft 186 88 1 60For submerged flow a depth of flow needs to be taken upstream Ha and downstream Hb See locations of Ha and Hb in Figure 1 12 Flume size St1 3 in 0 56 9 in 0 61 8 ft 0 710 50 ft 0 8If Hb Ha is greater or equal to St then it is a submerged flow If there is submerged flow adjustments need to be made in order for the Parshall Flume to work properly The discharge Q can be found using the following equations and table Qnet Qfree flow Qcorrection Qcorrection M 0 000132 Ha2 123 e9 284 St where S Hb Ha M multiplying factor Note All various Q values are in ft3 s Ha is in feet and M varies in units Table 3 12 Size of flume Ft Multiplying factor M1 11 5 1 42 1 83 2 44 3 15 3 76 4 37 4 98 5 4Example EditParshall Flume Free Flow Example Problem Using the Parshall flume free flow equation determine the discharge of a 72 inch flume with a depth Ha of 3 feet From Table 1 Throat width 72 in 6 ft C 24 and n 1 59 Q 24 Ha1 59 for a 72 inch Parshall flumeSo if there is a depth of 3 feet the flow rate is 140 ft3 sApproximate the discharge using the derived discharge equation shown above Equation 5 This equation was derived using the principles of specific energy and is only to serve as an estimate for the actual discharge of the Parshall flume Again equations 5 and 6 will always underestimate the actual flow since both the derived C and n values are lower than their respective empirically derived chart values Q 6 ft 3 088 3 ft 1 5 96 ft3 sParshall flume submerged flow example problem Using the Parshall flume flow equations and Tables 1 3 determine the flow type free flow or submerged flow and discharge for a 36 inch flume with an upstream depth Ha of 1 5 ft and a downstream depth Hb of 1 4 ft For reference of locations Ha and Hb refer to Figure 1 From Table 2 the Parshall Flume submergence transition St for a 36 inch 3 feet flume is 0 7 Since Hb Ha is greater than or equal to 0 7 it is a submerged flow Qnet Qfree flow Qcorrection Q CHanFrom Table 1 Throat width 36 in 3 ft C 12 and n 1 57 Qfree flow 12 1 5 ft 1 57 22 68 ft3 s Qcorrection M 0 000132 Ha 2 123 109 284 SWhere S Hb Ha 1 4 ft 1 5 ft 0 93From Table 3 M 2 4 for a flume size of 3 ft Qcorrection 2 4 0 000132 1 5 ft 2 123 109 284 0 93 4 21 ft3 s Qnet 22 68 ft3 s 4 21 ft3 s 18 5 ft3 sConstruction EditA wide variety of materials are used to make Parshall flumes including 13 Fiberglass 14 wastewater applications due to its corrosion resistance Stainless steel 15 applications involving high temperatures corrosive flow streams Galvanized steel 16 water rights irrigation Concrete large Parshall throat widths 144 in 3 66 m and above Aluminum 17 portable applications Wood temporary flow measurement Plastic PVC or polycarbonate Lexan teaching laboratory investigation Smaller Parshall flumes tend to be fabricated from fiberglass and galvanized steel depending upon the application while larger Parshall flumes tend to fabricated from fiberglass sizes up to 144 in or concrete 160 600 in 18 By the 1960s several different companies began to commercially offer Parshall flumes These manufacturers have typically produce flumes from one type of material only typically glass reinforce plastic or steel although currently a few offer Parshall flumes in a variety of materials Installation EditDr Parshall s initial focus was for the use of his namesake flume to measure flows in irrigation channels and other surface waters Over time however the Parshall flume has proven to be applicable to a wide variety of open channel flows including Irrigation channels and ditches Furrows Surface waters swales creeks streams and rivers Elevated above grade piped flows Below grade piped flows concrete vaults manholes incorporated into Packaged Metering Manholes Drawbacks EditParshall flumes require a drop in elevation through the flume To accommodate the drop in an existing channel either the flume must be raised above the channel floor raising the upstream water level or the downstream channel must be modified As with weirs flumes can also have an effect on local fauna Some species or certain life stages of the same species may be blocked by flumes due to relatively slow swim speeds or behavioral characteristics In earthen channels upstream bypass and downstream scour may occur Armoring of the upstream and downstream channels is recommended Parshall flumes below 3 inches in size should not be used on unscreened sanitary flows due to the likelihood of clogging 19 The Parshall flume is an empirical device Interpolation between sizes is not an accurate method of developing intermediate size Parshall flumes as the flumes are not scale models of each other 20 21 22 The 30 inch 76 2 cm and 42 inch 106 7 cm sizes are examples of intermediate sizes of Parshall flumes that have crept into the marketplace without the backing of published research into their sizing and flow rates 23 Variations EditTwo variations of the Parshall flume have been developed over time the Montana flume and the Short Section USGS Portable Parshall flume 24 Montana flume Edit The Montana flume omits the throat and discharge sections of the Parshall 25 By omitting these sections the flume is shortened by more than half while retaining the free flow characteristics of the same size Parshall With the deletion of the throat and discharge section the Montana flume has little resistance to submersion and like the H flume should be used where free spilling discharge is present under all flow conditions The Montana flume is described in US Bureau of Reclamation s Water Measurement Manual 26 and two technical standards MT199127AG 27 and MT199128AG 28 by Montana State University note that Montana State University has currently withdrawn both standards for updating review Short Section USGS Portable Parshall flume Edit The short section Parshall sometimes referred to as a USGS or Portable Parshall omits the discharge section of the flume Originally designed by Troxell and Taylor in 1931 and published under Venturi Flume as a memorandum from the office of the Ground Water Branch USGS the design was again brought to the attention of potential users in Taylors paper Portable Venturi Flume for Measuring Small Flows in 1954 29 This modification supplied by the USGS Hydrologic Instrumentation Facility is available in two sizes the original 3 and the recently added 6 30 Kilpatrick notes that the discharge for this modification of the Parshall flume is slightly greater than for a standard Parshall flume of the same size 31 This has been attributed to potential manufacturing tolerance variations rather than the actual operation of the flume itself and users are cautioned to verify the flume s dimensions before proceeding with data collection As with any Parshall flume flumes varying from the standard dimensions flumes should be individual rated When used for stream gauging aluminum is the typical material of construction primarily due to its light weight References Edit USBR Water Measurement Manual Chapter 8 FLUMES Section 10 Parshall Flumes Usbr gov Archived from the original on 2003 06 14 Retrieved 2013 04 15 Parshall Flumes for Flow Measurement Openchannelflow Retrieved 2013 04 15 Flow Characteristics of Parshall Flumes Openchannelflow Retrieved 2013 04 15 Parshall Flume Submergence Openchannelflow Retrieved 2013 04 15 Parshall Flumes for Flow Measurement openchannelflow com Retrieved 2015 04 21 Flow Characteristics of Parshall Flumes openchannelflow com Retrieved 2015 04 21 Montana Flumes What are they openchannelflow com Retrieved 2015 04 21 The Improved Venturi Flume PDF digitool library colostate edu Retrieved 2015 04 21 permanent dead link de Sa D O 2001 Instrumentation Fundamentals for Process Control Taylor amp Francis p 9 ISBN 9781560329015 Retrieved 2015 04 21 Parshall Ralph 1928 The Improved Venturi Flume PDF Fort Collins CO Colorado Agricultural College Guide to the Ralph L Parshall Collection a b c USBR Water Measurement Manual Chapter 8 FLUMES Section 10 Parshall Flumes Archived from the original on 2013 04 10 Retrieved 2013 04 15 Field measurement of soil erosion and runoff Chapter 4 Streamflow Fao org Retrieved 2013 04 15 Fiberglass FRP Parshall Flumes www openchannelflow com Retrieved 2020 01 07 Stainless Steel Parshall Flumes www openchannelflow com Retrieved 2020 01 07 Galvanized Steel Parshall Flumes www openchannelflow com Retrieved 2020 01 07 Aluminum Parshall Flumes www openchannelflow com Retrieved 2020 01 07 Large Parshall Flumes www openchannelflow com Retrieved 2020 01 07 Don t Get Stuck Sanitary Flows in Flumes Water Measurement Manual Chapter 8 Section 10 Parshall Flumes Recommended Practice for the Use of Parshall Flumes and Palmer Bowlus Flumes in Wastewater Treatment Plants EPA600 2 84 186 November 1984 5 a href Template Cite journal html title Template Cite journal cite journal a Cite journal requires journal help Non Standard Parshall Flume Sizes USGS Portable Parshall Flumes Montana Flume Dimensions Water Measurement Manual Archived from the original on 2014 10 01 Retrieved 2013 03 26 MT199127AG Archived from the original on 2014 06 01 MT199128AG Archived from the original on 2014 06 01 http pubs usgs gov of 1963 0063 report pdf bare URL PDF USGS Hydrologic Instrumentation Facility Instrument Project Six inch modified Parshall Flume Portable Water usgs gov Retrieved 2016 09 03 Kilpatrick Schneider Techniques of Water Resources Investigations 3 Chapter A14 a href Template Cite journal html title Template Cite journal cite journal a Cite journal requires journal help External links EditPictures of fiberglass galvanized and stainless steel Parshall flumes Wikimedia Commons has media related to Parshall flumes Further reading EditASTM D1941 91 2013 Standard Test Method for Open Channel Flow Measurement of Water with the Parshall Flume ISO 9826 1992 Measurement of Liquid Flow in Open Channels Parshall and SANIIRI Flumes JIS B7553 1993 Parshall Flume Type Flowmeters Bos Marinus 1989 Discharge Measurement Structures Third edition revised Publication 20 Oxford United Kingdom International Institute for Land Reclamation and Improvement ISBN 978 9070754150 Grant Doug Dawson Brian 2001 ISCO Open Channel Flow Measurement Handbook 5th ed ISBN 978 0962275722 Retrieved from https en wikipedia org w index php title Parshall flume amp oldid 1105685260, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.