MicroTCA (short for Micro Telecommunications Computing Architecture, also: μTCA) is a modular, open standard, created and maintained by the PCI Industrial Computer Manufacturers Group (PICMG). It provides the electrical, mechanical, thermal and management specifications to create a switched fabric computer system, using Advanced Mezzanine Cards (AMC), connected directly to a backplane. MicroTCA is a descendant of the AdvancedTCA standard.[1]

History edit

The rapid expansion of mobile telecommunications and their associated services (such as text messages) at the beginning of the millennium increased the demand of processing power in telecommunication systems. The existing "carrier grade" (see RAS) computing architectures were not fit to house the high performance processors of the time.[2] In order to answer those demands, about 100 companies worked together in PICMG, resulting in the Advanced Telecommunications Architecture (AdvancedTCA, ATCA), published in 2002.

After the introduction of AdvancedTCA, a standard was developed, to cater towards smaller telecommunications systems at the edge of the network.[1] This standard was geared towards a more compact, less expensive systems, without cutting back on reliability or data throughput. This standard, called MicroTCA, was ratified 2006.

MicroTCA systems migrated after its release into non-telecommunication sectors, like defence, avionics and science. This resulted in extensions to the base-standard, called modules.

Modules edit

MicroTCA.0 edit

The base-specification for properties common to all other modules, ratified July 6, 2006.[3] This includes:

  • Mechanical specifications, like possible dimensions of card cages, backplanes and supported AMC-modules
  • Electrical specifications, like power distribution and interface layout
  • Thermal specifications, like possible cooling layouts or available cooling power
  • Management specifications

A second revision of the base-specifications was ratified January 16, 2020, containing some corrections, as well as alterations, necessary to implement higher speed Ethernet fabrics, like 10GBASE-KR and 40GBASE-KR4.[4]

MicroTCA.1 edit

This module adds specifications for ruggedized systems, using forced air for cooling. Possible scenarios for MicroTCA.1-based systems include outside plant telecom, industrial and aerospace environments[5]

MicroTCA.2 edit

This module adds specifications for more stringent requirements with regards to temperature, shock, vibration and other environmental conditions. These specifications are geared towards use in outside plant telecom, machine and transport industry, as well as military airborne, shipboard and ground mobile equipment.[6] MicroTCA.2 allows the use of air- and conduction-cooled AMC-modules.

MicroTCA.3 edit

This module adds specifications for even more stringent requirements with regards to temperature, shock, vibration and other environmental conditions. These specifications are geared towards use in outside plant telecom, machine and transport industry, as well as military airborne, shipboard and ground mobile equipment.[7] MicroTCA.3 requires the use of conduction-cooled AMC-modules.

MicroTCA.4 edit

This module extends the AMC with a Rear Transition Module (RTM), increasing PCB-space and modularity. AMC and RTM are connected with a connector, located in zone 3, defined in MicroTCA.0.[8] These specifications are geared towards use in large-scale scientific devices, like particle accelerators or telescopes.

Components of MicroTCA edit

Card Cage edit

The card cage (also: shelf, crate) houses all the other components and as such has two primary functions:

  • Provide mechanical stability to the other components
  • Ensure sufficient cooling

There exist a wide array of card cages. They usually differ in:

  • the type of modules they support (MTCA.0, MTCA.1, ...)
  • the number of slots they provide (typically between 2 and 12)
  • the architecture of the installed backplane (see below)
  • the cooling scheme they use (i.e. airflow front-to-back, bottom-to-top, side-to-side, conductive,...)

Backplane edit

The backplane is a printed circuit board, mounted directly into the card cage. It connects all other components of a MicroTCA system to each other and provides power, data access and management access to them.

Two types of power are distributed over the backplane, Management Power (+3.3 V) and Payload Power (+12 V). Unlike typical backplanes, where power is distributed to all components via a common "powerplane" in the PCB, on a MicroTCA backplane, Management and Payload Power are distributed to each component individually. While Management Power is provided to each module connected to a powered backplane, Payload Power has to be granted by the MicroTCA Carrier Hub (MCH), after ensuring that the module is MicroTCA-compatible.

The standard defines various communication buses, which the backplane can/should provide:

Cooling Unit edit

The Cooling Unit (CU) provides controlled air flow in air-flow-cooled card cages. It usually consists of an array of fans and a controller, which is connected to the backplane. The MicroTCA Carrier Hub (MCH) can read-out temperature sensors (if present) and fan speed, as well as change fan speed via IPMI. The Cooling Unit is usually fitted to a specific card cage. Some CUs are easily detachable (i.e. for cleaning or replacement), while other card cages come with integrated, non-detachable CUs.

Power Module edit

The Power Module (PM, also: Power Supply) converts the AC power from the power line to the +3.3 V Management Power (MP) and +12 V Payload Power (PP), both of which are DC. There exist a variety of power modules, which differ in:

  • form factor (i.e. double width, single width)
  • input voltage (110 V, 220 V, both)
  • output power (i.e. 600 W, 1000 W)

The power module senses the presence of a module in a slot via a specified pin in the module connector, and immediately provides that module with management power. Payload power is managed by the MicroTCA Carrier Hub (MCH), which communicates with the power module via IPMI.

The power module uses its own type of connector, and can thus only be installed into designated slots, which in turn can't carry any other type of module. Some card cages provide an additional power module slot for redundancy. In such a case, one slot is the primary, which will provide power by default, and the other one is secondary, providing power only, if the primary does not.

MicroTCA Carrier Hub edit

The MicroTCA Carrier Hub (MCH) is the central managing device of a MicroTCA card cage. It manages power distribution and cooling. It usually also provides Gigabit Ethernet and/or PCIe/Serial RapidIO switching. Some MCHs additionally provide clocking. As the name indicates, they are the hub of various star topologies (i.e. for Ethernet, PCIe) on the backplane and thus require dedicated slot(s). Some backplanes support two MCHs for redundancy. In this case there are two MCH slots, with one being designated primary, and one secondary.

Advanced Mezzanine Card edit

Advanced Mezzanine Card (AMC) is a standard for hot-plugable PCBs. It was originally developed to be used in AdvancedTCA systems. The standard specifies:

  • the dimensions of the PCB with two width variants (single, double) and three height variants (Compact, Mid-size, Full)
  • type, location and orientation of connectors (i.e. Zone 1, 2, 3)

There is a huge variation of functionalities, an AMC can fulfill:

  • Computing (i.e. a module with CPU, RAM, SSD and on-board graphics)
  • Storage (i.e. SSD carrier)
  • Graphics card
  • FPGA card (i.e. for signal processing)
  • FMC carrier
  • Digitizer card (Analog-Digital and Digital-Analog Conversion)
  • Clocking and Triggering
  • and others

Rear Transition Module (MTCA.4 only) edit

The Rear Transition Module (RTM) was added in the MicroTCA.4 standard. It is connected directly to an AMC via a connector, located in zone 3, requiring a double width AMC and RTM. An RTM has about the same dimensions, as an AMC, basically doubling the available PCB-space per slot in an MTCA.4 card cage. Its power is provided by the AMC. Thus an RTM can not operate on its own, but requires a paired AMC.

The zone 3 connector is electrically free configurable, making it possible, that a mechanically fitting AMC-RTM pair is electrically incompatible. To avoid damage due to that incompatibility, a mechanical code-pin was added to MTCA.4-compatible AMCs and RTMs, mechanically preventing the installation of an electrically incompatible RTM to an AMC.

The functionality of RTMs includes, but is not limited to:

  • RF-signal pre-/post-processing (i.e. filtering, Up-/Down-conversion, Vector De-/Modulation)
  • Digital signal pre-/post-processing
  • Clock-generation/-distribution
  • Device interfaces
  • Date storage
  • CPU (only MCH-RTM)

References edit

  1. ^ a b "MicroTCA Overview". PICMG. Retrieved 2021-10-20.
  2. ^ cpci_atca. "Successful AdvancedTCA history rides on many shoulders". PICMG Systems&Technology. Retrieved 2021-10-20.
  3. ^ "MicroTCA Base Specification". PICMG. Retrieved 2021-10-21.
  4. ^ "MicroTCA Base Specification R2.0". PICMG. Retrieved 2021-10-21.
  5. ^ "Air Cooled Rugged MicroTCA Specification". PICMG. Retrieved 2021-10-21.
  6. ^ "Hybrid Air/Conduction Cooled MicroTCA Specification". PICMG. Retrieved 2021-10-21.
  7. ^ "Hardened Conduction Cooled MicroTCA Specification". PICMG. Retrieved 2021-10-21.
  8. ^ "MicroTCA Enhancement for Rear I/O and Precision Timing Specification". PICMG. Retrieved 2021-10-21.

External links edit

  • MicroTCA.0 Standard Short Form
  • Helmholtz Innovation Lab at DESY, centered around MicroTCA: MicroTCA Technology Lab

microtca, short, micro, telecommunications, computing, architecture, also, μtca, modular, open, standard, created, maintained, industrial, computer, manufacturers, group, picmg, provides, electrical, mechanical, thermal, management, specifications, create, swi. MicroTCA short for Micro Telecommunications Computing Architecture also mTCA is a modular open standard created and maintained by the PCI Industrial Computer Manufacturers Group PICMG It provides the electrical mechanical thermal and management specifications to create a switched fabric computer system using Advanced Mezzanine Cards AMC connected directly to a backplane MicroTCA is a descendant of the AdvancedTCA standard 1 Contents 1 History 2 Modules 2 1 MicroTCA 0 2 2 MicroTCA 1 2 3 MicroTCA 2 2 4 MicroTCA 3 2 5 MicroTCA 4 3 Components of MicroTCA 3 1 Card Cage 3 2 Backplane 3 3 Cooling Unit 3 4 Power Module 3 5 MicroTCA Carrier Hub 3 6 Advanced Mezzanine Card 3 7 Rear Transition Module MTCA 4 only 4 References 5 External linksHistory editThe rapid expansion of mobile telecommunications and their associated services such as text messages at the beginning of the millennium increased the demand of processing power in telecommunication systems The existing carrier grade see RAS computing architectures were not fit to house the high performance processors of the time 2 In order to answer those demands about 100 companies worked together in PICMG resulting in the Advanced Telecommunications Architecture AdvancedTCA ATCA published in 2002 After the introduction of AdvancedTCA a standard was developed to cater towards smaller telecommunications systems at the edge of the network 1 This standard was geared towards a more compact less expensive systems without cutting back on reliability or data throughput This standard called MicroTCA was ratified 2006 MicroTCA systems migrated after its release into non telecommunication sectors like defence avionics and science This resulted in extensions to the base standard called modules Modules editMicroTCA 0 edit The base specification for properties common to all other modules ratified July 6 2006 3 This includes Mechanical specifications like possible dimensions of card cages backplanes and supported AMC modules Electrical specifications like power distribution and interface layout Thermal specifications like possible cooling layouts or available cooling power Management specificationsA second revision of the base specifications was ratified January 16 2020 containing some corrections as well as alterations necessary to implement higher speed Ethernet fabrics like 10GBASE KR and 40GBASE KR4 4 MicroTCA 1 edit This module adds specifications for ruggedized systems using forced air for cooling Possible scenarios for MicroTCA 1 based systems include outside plant telecom industrial and aerospace environments 5 MicroTCA 2 edit This module adds specifications for more stringent requirements with regards to temperature shock vibration and other environmental conditions These specifications are geared towards use in outside plant telecom machine and transport industry as well as military airborne shipboard and ground mobile equipment 6 MicroTCA 2 allows the use of air and conduction cooled AMC modules MicroTCA 3 edit This module adds specifications for even more stringent requirements with regards to temperature shock vibration and other environmental conditions These specifications are geared towards use in outside plant telecom machine and transport industry as well as military airborne shipboard and ground mobile equipment 7 MicroTCA 3 requires the use of conduction cooled AMC modules MicroTCA 4 edit This module extends the AMC with a Rear Transition Module RTM increasing PCB space and modularity AMC and RTM are connected with a connector located in zone 3 defined in MicroTCA 0 8 These specifications are geared towards use in large scale scientific devices like particle accelerators or telescopes Components of MicroTCA editCard Cage edit The card cage also shelf crate houses all the other components and as such has two primary functions Provide mechanical stability to the other components Ensure sufficient coolingThere exist a wide array of card cages They usually differ in the type of modules they support MTCA 0 MTCA 1 the number of slots they provide typically between 2 and 12 the architecture of the installed backplane see below the cooling scheme they use i e airflow front to back bottom to top side to side conductive Backplane edit The backplane is a printed circuit board mounted directly into the card cage It connects all other components of a MicroTCA system to each other and provides power data access and management access to them Two types of power are distributed over the backplane Management Power 3 3 V and Payload Power 12 V Unlike typical backplanes where power is distributed to all components via a common powerplane in the PCB on a MicroTCA backplane Management and Payload Power are distributed to each component individually While Management Power is provided to each module connected to a powered backplane Payload Power has to be granted by the MicroTCA Carrier Hub MCH after ensuring that the module is MicroTCA compatible The standard defines various communication buses which the backplane can should provide Gigabit Ethernet IPMI SATA Fat pipe can be used for PCIe SRIO or 10G 40G Ethernet Point to Point Links Clocks JTAGCooling Unit edit The Cooling Unit CU provides controlled air flow in air flow cooled card cages It usually consists of an array of fans and a controller which is connected to the backplane The MicroTCA Carrier Hub MCH can read out temperature sensors if present and fan speed as well as change fan speed via IPMI The Cooling Unit is usually fitted to a specific card cage Some CUs are easily detachable i e for cleaning or replacement while other card cages come with integrated non detachable CUs Power Module edit The Power Module PM also Power Supply converts the AC power from the power line to the 3 3 V Management Power MP and 12 V Payload Power PP both of which are DC There exist a variety of power modules which differ in form factor i e double width single width input voltage 110 V 220 V both output power i e 600 W 1000 W The power module senses the presence of a module in a slot via a specified pin in the module connector and immediately provides that module with management power Payload power is managed by the MicroTCA Carrier Hub MCH which communicates with the power module via IPMI The power module uses its own type of connector and can thus only be installed into designated slots which in turn can t carry any other type of module Some card cages provide an additional power module slot for redundancy In such a case one slot is the primary which will provide power by default and the other one is secondary providing power only if the primary does not MicroTCA Carrier Hub edit The MicroTCA Carrier Hub MCH is the central managing device of a MicroTCA card cage It manages power distribution and cooling It usually also provides Gigabit Ethernet and or PCIe Serial RapidIO switching Some MCHs additionally provide clocking As the name indicates they are the hub of various star topologies i e for Ethernet PCIe on the backplane and thus require dedicated slot s Some backplanes support two MCHs for redundancy In this case there are two MCH slots with one being designated primary and one secondary Advanced Mezzanine Card edit Main article Advanced Mezzanine Card Advanced Mezzanine Card AMC is a standard for hot plugable PCBs It was originally developed to be used in AdvancedTCA systems The standard specifies the dimensions of the PCB with two width variants single double and three height variants Compact Mid size Full type location and orientation of connectors i e Zone 1 2 3 There is a huge variation of functionalities an AMC can fulfill Computing i e a module with CPU RAM SSD and on board graphics Storage i e SSD carrier Graphics card FPGA card i e for signal processing FMC carrier Digitizer card Analog Digital and Digital Analog Conversion Clocking and Triggering and othersRear Transition Module MTCA 4 only edit The Rear Transition Module RTM was added in the MicroTCA 4 standard It is connected directly to an AMC via a connector located in zone 3 requiring a double width AMC and RTM An RTM has about the same dimensions as an AMC basically doubling the available PCB space per slot in an MTCA 4 card cage Its power is provided by the AMC Thus an RTM can not operate on its own but requires a paired AMC The zone 3 connector is electrically free configurable making it possible that a mechanically fitting AMC RTM pair is electrically incompatible To avoid damage due to that incompatibility a mechanical code pin was added to MTCA 4 compatible AMCs and RTMs mechanically preventing the installation of an electrically incompatible RTM to an AMC The functionality of RTMs includes but is not limited to RF signal pre post processing i e filtering Up Down conversion Vector De Modulation Digital signal pre post processing Clock generation distribution Device interfaces Date storage CPU only MCH RTM References edit a b MicroTCA Overview PICMG Retrieved 2021 10 20 cpci atca Successful AdvancedTCA history rides on many shoulders PICMG Systems amp Technology Retrieved 2021 10 20 MicroTCA Base Specification PICMG Retrieved 2021 10 21 MicroTCA Base Specification R2 0 PICMG Retrieved 2021 10 21 Air Cooled Rugged MicroTCA Specification PICMG Retrieved 2021 10 21 Hybrid Air Conduction Cooled MicroTCA Specification PICMG Retrieved 2021 10 21 Hardened Conduction Cooled MicroTCA Specification PICMG Retrieved 2021 10 21 MicroTCA Enhancement for Rear I O and Precision Timing Specification PICMG Retrieved 2021 10 21 External links editMicroTCA 0 Standard Short Form Helmholtz Innovation Lab at DESY centered around MicroTCA MicroTCA Technology Lab Retrieved from https en wikipedia org w index php title MicroTCA amp oldid 1199360879, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.