fbpx
Wikipedia

Hemofiltration

Hemofiltration, also haemofiltration, is a renal replacement therapy which is used in the intensive care setting. It is usually used to treat acute kidney injury (AKI), but may be of benefit in multiple organ dysfunction syndrome or sepsis.[1] During hemofiltration, a patient's blood is passed through a set of tubing (a filtration circuit) via a machine to a semipermeable membrane (the filter) where waste products and water (collectively called ultrafiltrate) are removed by convection. Replacement fluid is added and the blood is returned to the patient.[2]

Hemofiltration
Hemofilter ready for use.
Specialtynephrology
ICD-9-CM39.95
MeSHD006440
[edit on Wikidata]

As in dialysis, in hemofiltration one achieves movement of solutes across a semi-permeable membrane. However, solute movement with hemofiltration is governed by convection rather than by diffusion. With hemofiltration, dialysate is not used. Instead, a positive hydrostatic pressure drives water and solutes across the filter membrane from the blood compartment to the filtrate compartment, from which it is drained. Solutes, both small and large, get dragged through the membrane at a similar rate by the flow of water that has been engendered by the hydrostatic pressure. Thus convection overcomes the reduced removal rate of larger solutes (due to their slow speed of diffusion) seen in hemodialysis.

Hemodiafiltration edit

Hemofiltration is sometimes used in combination with hemodialysis, when it is termed hemodiafiltration. Blood is pumped through the blood compartment of a high flux dialyzer, and a high rate of ultrafiltration is used, so there is a high rate of movement of water and solutes from blood to dialysate that must be replaced by substitution fluid that is infused directly into the blood line. However, dialysis solution is also run through the dialysate compartment of the dialyzer. The combination is theoretically useful because it results in good removal of both large and small molecular weight solutes.[citation needed]

Intermittent vs. continuous edit

These treatments can be given intermittently, or continuously. The latter is usually done in an intensive care unit setting. There may be little difference in clinical and health economic outcome between the two in the context of acute kidney failure.[3][4]

On-line intermittent hemofiltration (IHF) or hemodiafiltration (IHDF) edit

Either of these treatments can be given in outpatient dialysis units, three or more times a week, usually 3–5 hours per treatment. IHDF is used almost exclusively, with only a few centers using IHF. With both IHF or IHDF, the substitution fluid is prepared on-line from dialysis solution by running dialysis solution through a set of two membranes to purify it before infusing it directly into the blood line. In the United States, regulatory agencies have not yet approved on-line creation of substitution fluid because of concerns about its purity. For this reason, hemodiafiltration, had historically never been used in an outpatient setting in the United States.[citation needed]

Continuous hemofiltration or hemodiafiltration (CHDF) edit

Continuous hemofiltration (CHF) was first described in a 1977 paper by Kramer et al. as a treatment for fluid overload.[5] Hemofiltration is most commonly used in an intensive care unit setting, where it is either given as 8- to 12-hour treatments, so called SLEF (slow extended hemofiltration), or as CHF (continuous hemofiltration), also sometimes called continuous veno-venous hemofiltration (CVVH) or continuous renal replacement therapy (CRRT).[6][7] Hemodiafiltration (SLED-F or CHDF or CVVHDF) also is widely used in this fashion. In the United States, the substitution fluid used in CHF or CHDF is commercially prepared, prepackaged, and sterile (or sometimes is prepared in the local hospital pharmacy), avoiding regulatory issues of on-line creation of replacement fluid from dialysis solution.

With slow continuous therapies, the blood flow rates are usually in the range of 100-200 ml/min, and access is usually achieved through a central venous catheter placed in one of the large central veins. In such cases a blood pump is used to drive blood flow through the filter. Native access for hemodialysis (e.g. AV fistulas or grafts) are unsuitable for CHF because the prolonged residence of the access needles required might damage such accesses.

The length of time before the circuit clots and becomes unusable, often referred to as circuit life, can vary depending on the medication used to keep blood from clotting. Heparin and regional citrate are often used, though heparin carries a higher risk of bleeding.[8] However, a comprehensive analysis of audit data from intensive care units in the UK revealed that, compared with heparin, citrate-based drugs were not associated with fewer deaths among patients with acute kidney injury after 90 days of treatment. Citrate-based drugs were, however, associated with a substantially higher cost of treatment.[9][10]

History of Continuous Renal Replacement Therapy edit

Before implementing continuous renal replacement therapy (CRRT), acute renal failure (ARF) in critically ill, multiple organ failure patients was managed by intermittent hemodialysis and the mortality rate was very high.[11] Hemodialysis is effective in clearance and ultrafiltration, but it has deleterious effects on hemodynamic stability.[12] In 1971, Lee Henderson described the basis for convective transport in blood purification techniques. Subsequently, in 1974 he described hemodiafiltration combining convection and diffusion. These seminal papers represented the basis for the development of chronic hemodiafiltration by Leber and continuous arteriovenous hemofiltration (CAVH) by Peter Kramer.[13]

With his team, Peter Kramer (Died unexpectedly in 1984), had actually first reported the use of continuous hemofiltration in Germany in 1977.[14] Peter Kramer in ASAIO presented a paper describing the use of arteriovenous hemofiltration in the management of ARF.[15] Kramer tried that as a mean of managing diuretic-resistant fluid overload. Kramer described his experience of attaching a microporous hemofilter to the femoral artery and vein, and flowing blood through it at around 100 ml/minuets Liters of plasma filtrate poured out. He replaced it with an infusion of electrolyte solution.[16] Kramer explained that this could be done continuously, avoiding the volume shifts and other problems of intermittent hemodialysis. For those in the audience who cared for patients with anuric ARF, this was an epiphany of thunderbolt proportions.[17] He used a hollow fiber “haemofilter” that originally designed as an alternative to HD for chronic renal failure and produced 300-600 ml/hour of ultrafiltrate by convection. The simple, pumpless system made use of temporary dialysis catheters sited in the patient’s femoral artery and vein and could be rapidly established in critically ill patients.[18] Kramer explained that this could be done continuously, avoiding the volume shifts and other problems of intermittent hemodialysis. For those in the audience who cared for patients with anuric ARF, this was an epiphany of thunderbolt proportions.[19] He used a hollow fiber “haemofilter” that originally designed as an alternative to HD for chronic renal failure and produced 300-600 ml/hour of ultrafiltrate by convection. The simple, pumpless system made use of temporary dialysis catheters sited in the patient’s femoral artery and vein and could be rapidly established in critically ill patients. Using an isotonic salt solution for fluid replacement, continuous arteriovenous hemofiltration (CAVH) was soon extended to the management of ARF. In 1982, Kramer presented his experience with its use in more than 150 intensive care patients at a meeting of the American Society for Artificial Internal Organs(ASAIO).[20] Before that, Henderson et al and Knopp, had studied hemofiltration in animals and as an alternative to dialysis in chronic renal failure, but it was really Peter Kramer’s report in ASAIO meeting in 1982 that stimulated many of nephrologists and intensivists to undertake the serious evaluation of CAVH in ARF in the ICU.[21]

At first, in CAVH, the prescribed ultrafiltration rate was achieved manually by arranging the filtrate bag at the right height, thereby changing the negative pressure caused by the filtrate column. The replacement fluid was also regulated manually. Few years later, CAVH was developed in several centers for managing ARF in critically ill patients with multiple organ failure. In 1986, it has been reported that CAVH improve the patient survival from 9% to 38% with full nutrition in ARF.[22] Moreover, a workshop presented at ASAIO in 1988 summarized the development and role of continuous hemofiltration.[23] Since late 1980s, continuous renal replacement therapy (CRRT) has been studied extensively. In 1982, the use of CAVH in Vicenza was extended for the first time to a neonate with the application of specific minifilters . Two years later, CAVH began to be used to treat septic patients, burn patients and patients after transplantation and cardiac surgery, even with regional citrate anticoagulation.[24] In 1986, the term continuous renal replacement therapy was applied to all these continuous approaches.[25] The technology and terminology were expanded to include slow continuous ultrafiltration for fluid removal without replacement, continuous arteriovenous hemodialysis (CAVHD), and continuous arteriovenous hemodiafiltration.[26] Meanwhile, clinical and technical limitations of CAVH spurred new research and the discovery of new treatments, leading to the development of continuous veno-venous hemofiltration (CVVH), continuous veno-venous hemodialysis (CVVHD) and continuous veno-venous hemodiafiltration (CVVHDF). The low depurative efficiency was overcome by applying filters with two ports in the dialysate/filtrate compartment and through the use of counter-current dialysate flow, allowing the addition of diffusion and the birth of continuous arteriovenous hemodiafiltration or hemodialysis (CAVHDF or CAVHD).[27]

Development of double-lumen venous catheters and peristaltic blood pumps was invented in the mid-1980s, when CVVH was proposed. The presence of a pump that generated negative pressure in part of the circuit made it necessary to add a device to detect the presence of air and a sensor to monitor the pressure in the circuit, to avoid, respectively, air embolisms and circuit explosion in case of coagulation or obstruction of the venous line. Later, ultrafiltrate and replacement pumps and a heater were added to the circuit.[28] The development of CVVH allows to increase the exchange volumes, and subsequently, the depurative efficiency. The use of counter-current dialysate flow led to further improvements and the birth of CVVHD and CVVHDF.[29] Now Continuous renal replacement therapy has become the mainstay of management of renal failure for multiple organ failure patients in the ICU.[30]

Information technology and precision medicine have recently furthered the evolution of CRRT, providing the possibility of collecting data in large databases and evaluating policies and practice patterns. The application of artificial intelligence and enhanced human intelligence programs to the analysis of big data has further moved the front of research ahead, providing the possibility of creating silica-trials and finding answers to patients’ unmet clinical needs. The opportunity to evaluate the endophenotype of the patient makes it possible to adjust treatments and techniques by implementing the concept of precision CRRT. This allows clinicians to normalize outcomes and results among different populations or individuals and establish optimal and personalized care [31]

See also edit

References edit

  1. ^ Cruz D, Bellomo R, Kellum J, de Cal M, Ronco C (2008). "The future of extracorporeal support". Critical Care Medicine. 36 (Suppl): S243–S252. doi:10.1097/CCM.0b013e318168e4f6. PMID 18382201. S2CID 7896249.{{cite journal}}: CS1 maint: multiple names: authors list (link)
  2. ^ Hoffmann JN, Faist E (2001). "Removal of mediators by continuous hemofiltration in septic patients". World Journal of Surgery. 25 (5): 651–659. doi:10.1007/s002680020027. PMID 11369995. S2CID 10197867.
  3. ^ Pannu N, Klarenbach S, Wiebe N, Manns B, Tonelli M (2008). "Renal replacement therapy in patients with acute renal failure". JAMA. 299 (7): 793–805. doi:10.1001/jama.299.7.793. PMID 18285591.{{cite journal}}: CS1 maint: multiple names: authors list (link)
  4. ^ Singh, Ambrish; Hussain, Salman; Kher, Vijay; Palmer, Andrew J.; Jose, Matthew; Antony, Benny (2021). "A systematic review of cost-effectiveness analyses of continuous versus intermittent renal replacement therapy in acute kidney injury". Expert Review of Pharmacoeconomics & Outcomes Research. 22 (1): 1–9. doi:10.1080/14737167.2021.1916471. PMID 33934689. S2CID 233484979.
  5. ^ Kramer P, Wigger W, Rieger J, Matthaei D, Scheler F (1977). "Arteriovenous haemofiltration: a new and simple method for treatment of over-hydrated patients resistant to diuretics". Klinische Wochenschrift. 55 (22): 1121–1122. doi:10.1007/BF01477940. PMID 592681. S2CID 23461753.{{cite journal}}: CS1 maint: multiple names: authors list (link)
  6. ^ Bellomo R, Ronco C (1999). "Continuous renal replacement therapy in the intensive care unit". Intensive Care Medicine. 25 (8): 781–789. doi:10.1007/s001340050953. PMID 10447534. S2CID 33160535.
  7. ^ Abdeen O, Mehta RL (April 2002). "Dialysis modalities in the intensive care unit". Critical Care Clinics. 18 (2): 223–247. doi:10.1016/s0749-0704(01)00007-0. PMID 12053832.
  8. ^ Wu M, Hsu Y, Bai C, Lin Y, Wu C, Tam K (2012). "Regional citrate versus heparin anticoagulation for continuous renal replacement therapy: a meta-analysis of randomized controlled trials". American Journal of Kidney Diseases. 59 (6): 810–818. doi:10.1053/j.ajkd.2011.11.030. PMID 22226564.
  9. ^ "No benefit from citrate anticoagulation for treatment of kidney injury". NIHR Evidence. 2022-09-22. doi:10.3310/nihrevidence_53421. S2CID 252488546. Retrieved 2022-10-05.
  10. ^ Gould, Doug W; Doidge, James; Sadique, M Zia; Borthwick, Mark; Hatch, Robert; Caskey, Fergus J; Forni, Lui; Lawrence, Robert F; MacEwen, Clare; Ostermann, Marlies; Mouncey, Paul R; Harrison, David A; Rowan, Kathryn M; Young, J Duncan; Watkinson, Peter J (February 2022). "Heparin versus citrate anticoagulation for continuous renal replacement therapy in intensive care: the RRAM observational study". Health Technology Assessment. 26 (13): 1–58. doi:10.3310/ZXHI9396. ISSN 1366-5278. PMC 8899910. PMID 35212260.
  11. ^ Stott, R.B.; Ogg, C.S.; Cameron, J.S.; Bewick, M. (July 1972). "WHY THE PERSISTENTLY HIGH MORTALITY IN ACUTE RENAL FAILURE ?". The Lancet. 300 (7767): 75–79. doi:10.1016/s0140-6736(72)91562-0. ISSN 0140-6736.
  12. ^ Manns, M.; Sigler, M. H.; Teehan, B. P. (March 1996). "RENAL FUNCTION CHANGES DURING INTERMITTENT HEMODIALYSIS (IHD) VERSUS CONTINUOUS HEMODIALYSIS (CWHD) IN ACUTE RENAL FAILURE (ARF)". ASAIO Journal. 42 (2): 78. doi:10.1097/00002480-199603000-00292. ISSN 1058-2916.
  13. ^ Samoni, Sara; Husain-Syed, Faeq; Villa, Gianluca; Ronco, Claudio (2021-12-29). "Continuous Renal Replacement Therapy in the Critically Ill Patient: From Garage Technology to Artificial Intelligence". Journal of Clinical Medicine. 11 (1): 172. doi:10.3390/jcm11010172. ISSN 2077-0383. PMC 8745413.
  14. ^ Kramer, P.; Wigger, W.; Rieger, J.; Matthaei, D.; Scheler, F. (November 1977). "Arteriovenous haemofiltration: A new and simple method for treatment of over-hydrated patients resistant to diuretics". Klinische Wochenschrift. 55 (22): 1121–1122. doi:10.1007/bf01477940. ISSN 0023-2173.
  15. ^ Schrader, J.; Kaiser, H.; Eisenhauer, T.; Kramer, P.; Köstering, H.; Scheler, F. (1985), "Anticoagulation in Continuous Arteriovenous Hemofiltration", Arteriovenous Hemofiltration, Berlin, Heidelberg: Springer Berlin Heidelberg, pp. 72–83, ISBN 978-3-540-15317-7, retrieved 2023-10-05
  16. ^ Featherstone, Peter J; Ball, Christine M (May 2019). "A brief history of haemodialysis and continuous renal replacement therapy". Anaesthesia and Intensive Care. 47 (3): 220–222. doi:10.1177/0310057x19853391. ISSN 0310-057X.
  17. ^ Bartlett, Robert H. (May 2018). "The Origins of Continuous Renal Replacement Therapy". ASAIO Journal. 64 (3): 427–430. doi:10.1097/mat.0000000000000573. ISSN 1058-2916.
  18. ^ Featherstone, Peter J; Ball, Christine M (May 2019). "A brief history of haemodialysis and continuous renal replacement therapy". Anaesthesia and Intensive Care. 47 (3): 220–222. doi:10.1177/0310057x19853391. ISSN 0310-057X.
  19. ^ Bartlett, Robert H. (May 2018). "The Origins of Continuous Renal Replacement Therapy". ASAIO Journal. 64 (3): 427–430. doi:10.1097/mat.0000000000000573. ISSN 1058-2916.
  20. ^ Featherstone, Peter J; Ball, Christine M (May 2019). "A brief history of haemodialysis and continuous renal replacement therapy". Anaesthesia and Intensive Care. 47 (3): 220–222. doi:10.1177/0310057x19853391. ISSN 0310-057X.
  21. ^ Bartlett, Robert H. (May 2018). "The Origins of Continuous Renal Replacement Therapy". ASAIO Journal. 64 (3): 427–430. doi:10.1097/mat.0000000000000573. ISSN 1058-2916.
  22. ^ Mault, J. R.; Bartlett, R. H. (1985), "Energy Balance and Survival in Patients with Acute Renal Failure", Arteriovenous Hemofiltration, Berlin, Heidelberg: Springer Berlin Heidelberg, pp. 154–160, ISBN 978-3-540-15317-7, retrieved 2023-10-05
  23. ^ Bartlett, R. (1986), "Nutrition in Acute Renal Failure: Treatment Made Possible by Continuous Arteriovenous Hemofiltration (CAVH)", Acute Continuous Renal Replacement Therapy, Boston, MA: Springer US, pp. 173–183, ISBN 978-1-4612-9422-1, retrieved 2023-10-05
  24. ^ Samoni, Sara; Husain-Syed, Faeq; Villa, Gianluca; Ronco, Claudio (2021-12-29). "Continuous Renal Replacement Therapy in the Critically Ill Patient: From Garage Technology to Artificial Intelligence". Journal of Clinical Medicine. 11 (1): 172. doi:10.3390/jcm11010172. ISSN 2077-0383. PMC 8745413.
  25. ^ Bartlett, Robert H. (May 2018). "The Origins of Continuous Renal Replacement Therapy". ASAIO Journal. 64 (3): 427–430. doi:10.1097/mat.0000000000000573. ISSN 1058-2916.
  26. ^ Ronco, Claudio (2017-05-31). "Continuous Renal Replacement Therapy: Forty-year Anniversary". The International Journal of Artificial Organs. 40 (6): 257–264. doi:10.5301/ijao.5000610. ISSN 0391-3988. PMC 6159848.
  27. ^ Samoni, Sara; Husain-Syed, Faeq; Villa, Gianluca; Ronco, Claudio (2021-12-29). "Continuous Renal Replacement Therapy in the Critically Ill Patient: From Garage Technology to Artificial Intelligence". Journal of Clinical Medicine. 11 (1): 172. doi:10.3390/jcm11010172. ISSN 2077-0383. PMC 8745413.
  28. ^ Henderson, Lee W. (1985), "Discovery and Relative Importance of Continuous Arteriovenous Hemofiltration", Arteriovenous Hemofiltration, Berlin, Heidelberg: Springer Berlin Heidelberg, pp. 1–2, ISBN 978-3-540-15317-7, retrieved 2023-10-05
  29. ^ Samoni, Sara; Husain-Syed, Faeq; Villa, Gianluca; Ronco, Claudio (2021-12-29). "Continuous Renal Replacement Therapy in the Critically Ill Patient: From Garage Technology to Artificial Intelligence". Journal of Clinical Medicine. 11 (1): 172. doi:10.3390/jcm11010172. ISSN 2077-0383. PMC 8745413.
  30. ^ PAGANINI, EMIL P.; SUHOZA, KAREN; SWANN, SAMUEL; GOLDING, LEONARD; NAKAMOTO, SATORU (July 1986). "Continuous Renal Replacement Therapy in Patients with Acute Renal Dysfunction Undergoing Intraaortic Balloon Pump and/or Left Ventricular Device Support". ASAIO Transactions. 32 (1): 414–417. doi:10.1097/00002216-198609000-00005. ISSN 0889-7190.
  31. ^ Samoni, Sara; Husain-Syed, Faeq; Villa, Gianluca; Ronco, Claudio (2021-12-29). "Continuous Renal Replacement Therapy in the Critically Ill Patient: From Garage Technology to Artificial Intelligence". Journal of Clinical Medicine. 11 (1): 172. doi:10.3390/jcm11010172. ISSN 2077-0383. PMC 8745413.

hemofiltration, also, haemofiltration, renal, replacement, therapy, which, used, intensive, care, setting, usually, used, treat, acute, kidney, injury, benefit, multiple, organ, dysfunction, syndrome, sepsis, during, hemofiltration, patient, blood, passed, thr. Hemofiltration also haemofiltration is a renal replacement therapy which is used in the intensive care setting It is usually used to treat acute kidney injury AKI but may be of benefit in multiple organ dysfunction syndrome or sepsis 1 During hemofiltration a patient s blood is passed through a set of tubing a filtration circuit via a machine to a semipermeable membrane the filter where waste products and water collectively called ultrafiltrate are removed by convection Replacement fluid is added and the blood is returned to the patient 2 HemofiltrationHemofilter ready for use SpecialtynephrologyICD 9 CM39 95MeSHD006440 edit on Wikidata As in dialysis in hemofiltration one achieves movement of solutes across a semi permeable membrane However solute movement with hemofiltration is governed by convection rather than by diffusion With hemofiltration dialysate is not used Instead a positive hydrostatic pressure drives water and solutes across the filter membrane from the blood compartment to the filtrate compartment from which it is drained Solutes both small and large get dragged through the membrane at a similar rate by the flow of water that has been engendered by the hydrostatic pressure Thus convection overcomes the reduced removal rate of larger solutes due to their slow speed of diffusion seen in hemodialysis Contents 1 Hemodiafiltration 2 Intermittent vs continuous 2 1 On line intermittent hemofiltration IHF or hemodiafiltration IHDF 2 2 Continuous hemofiltration or hemodiafiltration CHDF 3 History of Continuous Renal Replacement Therapy 4 See also 5 ReferencesHemodiafiltration editHemofiltration is sometimes used in combination with hemodialysis when it is termed hemodiafiltration Blood is pumped through the blood compartment of a high flux dialyzer and a high rate of ultrafiltration is used so there is a high rate of movement of water and solutes from blood to dialysate that must be replaced by substitution fluid that is infused directly into the blood line However dialysis solution is also run through the dialysate compartment of the dialyzer The combination is theoretically useful because it results in good removal of both large and small molecular weight solutes citation needed Intermittent vs continuous editThese treatments can be given intermittently or continuously The latter is usually done in an intensive care unit setting There may be little difference in clinical and health economic outcome between the two in the context of acute kidney failure 3 4 On line intermittent hemofiltration IHF or hemodiafiltration IHDF edit Either of these treatments can be given in outpatient dialysis units three or more times a week usually 3 5 hours per treatment IHDF is used almost exclusively with only a few centers using IHF With both IHF or IHDF the substitution fluid is prepared on line from dialysis solution by running dialysis solution through a set of two membranes to purify it before infusing it directly into the blood line In the United States regulatory agencies have not yet approved on line creation of substitution fluid because of concerns about its purity For this reason hemodiafiltration had historically never been used in an outpatient setting in the United States citation needed Continuous hemofiltration or hemodiafiltration CHDF edit Continuous hemofiltration CHF was first described in a 1977 paper by Kramer et al as a treatment for fluid overload 5 Hemofiltration is most commonly used in an intensive care unit setting where it is either given as 8 to 12 hour treatments so called SLEF slow extended hemofiltration or as CHF continuous hemofiltration also sometimes called continuous veno venous hemofiltration CVVH or continuous renal replacement therapy CRRT 6 7 Hemodiafiltration SLED F or CHDF or CVVHDF also is widely used in this fashion In the United States the substitution fluid used in CHF or CHDF is commercially prepared prepackaged and sterile or sometimes is prepared in the local hospital pharmacy avoiding regulatory issues of on line creation of replacement fluid from dialysis solution With slow continuous therapies the blood flow rates are usually in the range of 100 200 ml min and access is usually achieved through a central venous catheter placed in one of the large central veins In such cases a blood pump is used to drive blood flow through the filter Native access for hemodialysis e g AV fistulas or grafts are unsuitable for CHF because the prolonged residence of the access needles required might damage such accesses The length of time before the circuit clots and becomes unusable often referred to as circuit life can vary depending on the medication used to keep blood from clotting Heparin and regional citrate are often used though heparin carries a higher risk of bleeding 8 However a comprehensive analysis of audit data from intensive care units in the UK revealed that compared with heparin citrate based drugs were not associated with fewer deaths among patients with acute kidney injury after 90 days of treatment Citrate based drugs were however associated with a substantially higher cost of treatment 9 10 History of Continuous Renal Replacement Therapy editBefore implementing continuous renal replacement therapy CRRT acute renal failure ARF in critically ill multiple organ failure patients was managed by intermittent hemodialysis and the mortality rate was very high 11 Hemodialysis is effective in clearance and ultrafiltration but it has deleterious effects on hemodynamic stability 12 In 1971 Lee Henderson described the basis for convective transport in blood purification techniques Subsequently in 1974 he described hemodiafiltration combining convection and diffusion These seminal papers represented the basis for the development of chronic hemodiafiltration by Leber and continuous arteriovenous hemofiltration CAVH by Peter Kramer 13 With his team Peter Kramer Died unexpectedly in 1984 had actually first reported the use of continuous hemofiltration in Germany in 1977 14 Peter Kramer in ASAIO presented a paper describing the use of arteriovenous hemofiltration in the management of ARF 15 Kramer tried that as a mean of managing diuretic resistant fluid overload Kramer described his experience of attaching a microporous hemofilter to the femoral artery and vein and flowing blood through it at around 100 ml minuets Liters of plasma filtrate poured out He replaced it with an infusion of electrolyte solution 16 Kramer explained that this could be done continuously avoiding the volume shifts and other problems of intermittent hemodialysis For those in the audience who cared for patients with anuric ARF this was an epiphany of thunderbolt proportions 17 He used a hollow fiber haemofilter that originally designed as an alternative to HD for chronic renal failure and produced 300 600 ml hour of ultrafiltrate by convection The simple pumpless system made use of temporary dialysis catheters sited in the patient s femoral artery and vein and could be rapidly established in critically ill patients 18 Kramer explained that this could be done continuously avoiding the volume shifts and other problems of intermittent hemodialysis For those in the audience who cared for patients with anuric ARF this was an epiphany of thunderbolt proportions 19 He used a hollow fiber haemofilter that originally designed as an alternative to HD for chronic renal failure and produced 300 600 ml hour of ultrafiltrate by convection The simple pumpless system made use of temporary dialysis catheters sited in the patient s femoral artery and vein and could be rapidly established in critically ill patients Using an isotonic salt solution for fluid replacement continuous arteriovenous hemofiltration CAVH was soon extended to the management of ARF In 1982 Kramer presented his experience with its use in more than 150 intensive care patients at a meeting of the American Society for Artificial Internal Organs ASAIO 20 Before that Henderson et al and Knopp had studied hemofiltration in animals and as an alternative to dialysis in chronic renal failure but it was really Peter Kramer s report in ASAIO meeting in 1982 that stimulated many of nephrologists and intensivists to undertake the serious evaluation of CAVH in ARF in the ICU 21 At first in CAVH the prescribed ultrafiltration rate was achieved manually by arranging the filtrate bag at the right height thereby changing the negative pressure caused by the filtrate column The replacement fluid was also regulated manually Few years later CAVH was developed in several centers for managing ARF in critically ill patients with multiple organ failure In 1986 it has been reported that CAVH improve the patient survival from 9 to 38 with full nutrition in ARF 22 Moreover a workshop presented at ASAIO in 1988 summarized the development and role of continuous hemofiltration 23 Since late 1980s continuous renal replacement therapy CRRT has been studied extensively In 1982 the use of CAVH in Vicenza was extended for the first time to a neonate with the application of specific minifilters Two years later CAVH began to be used to treat septic patients burn patients and patients after transplantation and cardiac surgery even with regional citrate anticoagulation 24 In 1986 the term continuous renal replacement therapy was applied to all these continuous approaches 25 The technology and terminology were expanded to include slow continuous ultrafiltration for fluid removal without replacement continuous arteriovenous hemodialysis CAVHD and continuous arteriovenous hemodiafiltration 26 Meanwhile clinical and technical limitations of CAVH spurred new research and the discovery of new treatments leading to the development of continuous veno venous hemofiltration CVVH continuous veno venous hemodialysis CVVHD and continuous veno venous hemodiafiltration CVVHDF The low depurative efficiency was overcome by applying filters with two ports in the dialysate filtrate compartment and through the use of counter current dialysate flow allowing the addition of diffusion and the birth of continuous arteriovenous hemodiafiltration or hemodialysis CAVHDF or CAVHD 27 Development of double lumen venous catheters and peristaltic blood pumps was invented in the mid 1980s when CVVH was proposed The presence of a pump that generated negative pressure in part of the circuit made it necessary to add a device to detect the presence of air and a sensor to monitor the pressure in the circuit to avoid respectively air embolisms and circuit explosion in case of coagulation or obstruction of the venous line Later ultrafiltrate and replacement pumps and a heater were added to the circuit 28 The development of CVVH allows to increase the exchange volumes and subsequently the depurative efficiency The use of counter current dialysate flow led to further improvements and the birth of CVVHD and CVVHDF 29 Now Continuous renal replacement therapy has become the mainstay of management of renal failure for multiple organ failure patients in the ICU 30 Information technology and precision medicine have recently furthered the evolution of CRRT providing the possibility of collecting data in large databases and evaluating policies and practice patterns The application of artificial intelligence and enhanced human intelligence programs to the analysis of big data has further moved the front of research ahead providing the possibility of creating silica trials and finding answers to patients unmet clinical needs The opportunity to evaluate the endophenotype of the patient makes it possible to adjust treatments and techniques by implementing the concept of precision CRRT This allows clinicians to normalize outcomes and results among different populations or individuals and establish optimal and personalized care 31 See also editHemodialysis Renal replacement therapy Extracorporeal therapyReferences edit Cruz D Bellomo R Kellum J de Cal M Ronco C 2008 The future of extracorporeal support Critical Care Medicine 36 Suppl S243 S252 doi 10 1097 CCM 0b013e318168e4f6 PMID 18382201 S2CID 7896249 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint multiple names authors list link Hoffmann JN Faist E 2001 Removal of mediators by continuous hemofiltration in septic patients World Journal of Surgery 25 5 651 659 doi 10 1007 s002680020027 PMID 11369995 S2CID 10197867 Pannu N Klarenbach S Wiebe N Manns B Tonelli M 2008 Renal replacement therapy in patients with acute renal failure JAMA 299 7 793 805 doi 10 1001 jama 299 7 793 PMID 18285591 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint multiple names authors list link Singh Ambrish Hussain Salman Kher Vijay Palmer Andrew J Jose Matthew Antony Benny 2021 A systematic review of cost effectiveness analyses of continuous versus intermittent renal replacement therapy in acute kidney injury Expert Review of Pharmacoeconomics amp Outcomes Research 22 1 1 9 doi 10 1080 14737167 2021 1916471 PMID 33934689 S2CID 233484979 Kramer P Wigger W Rieger J Matthaei D Scheler F 1977 Arteriovenous haemofiltration a new and simple method for treatment of over hydrated patients resistant to diuretics Klinische Wochenschrift 55 22 1121 1122 doi 10 1007 BF01477940 PMID 592681 S2CID 23461753 a href Template Cite journal html title Template Cite journal cite journal a CS1 maint multiple names authors list link Bellomo R Ronco C 1999 Continuous renal replacement therapy in the intensive care unit Intensive Care Medicine 25 8 781 789 doi 10 1007 s001340050953 PMID 10447534 S2CID 33160535 Abdeen O Mehta RL April 2002 Dialysis modalities in the intensive care unit Critical Care Clinics 18 2 223 247 doi 10 1016 s0749 0704 01 00007 0 PMID 12053832 Wu M Hsu Y Bai C Lin Y Wu C Tam K 2012 Regional citrate versus heparin anticoagulation for continuous renal replacement therapy a meta analysis of randomized controlled trials American Journal of Kidney Diseases 59 6 810 818 doi 10 1053 j ajkd 2011 11 030 PMID 22226564 No benefit from citrate anticoagulation for treatment of kidney injury NIHR Evidence 2022 09 22 doi 10 3310 nihrevidence 53421 S2CID 252488546 Retrieved 2022 10 05 Gould Doug W Doidge James Sadique M Zia Borthwick Mark Hatch Robert Caskey Fergus J Forni Lui Lawrence Robert F MacEwen Clare Ostermann Marlies Mouncey Paul R Harrison David A Rowan Kathryn M Young J Duncan Watkinson Peter J February 2022 Heparin versus citrate anticoagulation for continuous renal replacement therapy in intensive care the RRAM observational study Health Technology Assessment 26 13 1 58 doi 10 3310 ZXHI9396 ISSN 1366 5278 PMC 8899910 PMID 35212260 Stott R B Ogg C S Cameron J S Bewick M July 1972 WHY THE PERSISTENTLY HIGH MORTALITY IN ACUTE RENAL FAILURE The Lancet 300 7767 75 79 doi 10 1016 s0140 6736 72 91562 0 ISSN 0140 6736 Manns M Sigler M H Teehan B P March 1996 RENAL FUNCTION CHANGES DURING INTERMITTENT HEMODIALYSIS IHD VERSUS CONTINUOUS HEMODIALYSIS CWHD IN ACUTE RENAL FAILURE ARF ASAIO Journal 42 2 78 doi 10 1097 00002480 199603000 00292 ISSN 1058 2916 Samoni Sara Husain Syed Faeq Villa Gianluca Ronco Claudio 2021 12 29 Continuous Renal Replacement Therapy in the Critically Ill Patient From Garage Technology to Artificial Intelligence Journal of Clinical Medicine 11 1 172 doi 10 3390 jcm11010172 ISSN 2077 0383 PMC 8745413 Kramer P Wigger W Rieger J Matthaei D Scheler F November 1977 Arteriovenous haemofiltration A new and simple method for treatment of over hydrated patients resistant to diuretics Klinische Wochenschrift 55 22 1121 1122 doi 10 1007 bf01477940 ISSN 0023 2173 Schrader J Kaiser H Eisenhauer T Kramer P Kostering H Scheler F 1985 Anticoagulation in Continuous Arteriovenous Hemofiltration Arteriovenous Hemofiltration Berlin Heidelberg Springer Berlin Heidelberg pp 72 83 ISBN 978 3 540 15317 7 retrieved 2023 10 05 Featherstone Peter J Ball Christine M May 2019 A brief history of haemodialysis and continuous renal replacement therapy Anaesthesia and Intensive Care 47 3 220 222 doi 10 1177 0310057x19853391 ISSN 0310 057X Bartlett Robert H May 2018 The Origins of Continuous Renal Replacement Therapy ASAIO Journal 64 3 427 430 doi 10 1097 mat 0000000000000573 ISSN 1058 2916 Featherstone Peter J Ball Christine M May 2019 A brief history of haemodialysis and continuous renal replacement therapy Anaesthesia and Intensive Care 47 3 220 222 doi 10 1177 0310057x19853391 ISSN 0310 057X Bartlett Robert H May 2018 The Origins of Continuous Renal Replacement Therapy ASAIO Journal 64 3 427 430 doi 10 1097 mat 0000000000000573 ISSN 1058 2916 Featherstone Peter J Ball Christine M May 2019 A brief history of haemodialysis and continuous renal replacement therapy Anaesthesia and Intensive Care 47 3 220 222 doi 10 1177 0310057x19853391 ISSN 0310 057X Bartlett Robert H May 2018 The Origins of Continuous Renal Replacement Therapy ASAIO Journal 64 3 427 430 doi 10 1097 mat 0000000000000573 ISSN 1058 2916 Mault J R Bartlett R H 1985 Energy Balance and Survival in Patients with Acute Renal Failure Arteriovenous Hemofiltration Berlin Heidelberg Springer Berlin Heidelberg pp 154 160 ISBN 978 3 540 15317 7 retrieved 2023 10 05 Bartlett R 1986 Nutrition in Acute Renal Failure Treatment Made Possible by Continuous Arteriovenous Hemofiltration CAVH Acute Continuous Renal Replacement Therapy Boston MA Springer US pp 173 183 ISBN 978 1 4612 9422 1 retrieved 2023 10 05 Samoni Sara Husain Syed Faeq Villa Gianluca Ronco Claudio 2021 12 29 Continuous Renal Replacement Therapy in the Critically Ill Patient From Garage Technology to Artificial Intelligence Journal of Clinical Medicine 11 1 172 doi 10 3390 jcm11010172 ISSN 2077 0383 PMC 8745413 Bartlett Robert H May 2018 The Origins of Continuous Renal Replacement Therapy ASAIO Journal 64 3 427 430 doi 10 1097 mat 0000000000000573 ISSN 1058 2916 Ronco Claudio 2017 05 31 Continuous Renal Replacement Therapy Forty year Anniversary The International Journal of Artificial Organs 40 6 257 264 doi 10 5301 ijao 5000610 ISSN 0391 3988 PMC 6159848 Samoni Sara Husain Syed Faeq Villa Gianluca Ronco Claudio 2021 12 29 Continuous Renal Replacement Therapy in the Critically Ill Patient From Garage Technology to Artificial Intelligence Journal of Clinical Medicine 11 1 172 doi 10 3390 jcm11010172 ISSN 2077 0383 PMC 8745413 Henderson Lee W 1985 Discovery and Relative Importance of Continuous Arteriovenous Hemofiltration Arteriovenous Hemofiltration Berlin Heidelberg Springer Berlin Heidelberg pp 1 2 ISBN 978 3 540 15317 7 retrieved 2023 10 05 Samoni Sara Husain Syed Faeq Villa Gianluca Ronco Claudio 2021 12 29 Continuous Renal Replacement Therapy in the Critically Ill Patient From Garage Technology to Artificial Intelligence Journal of Clinical Medicine 11 1 172 doi 10 3390 jcm11010172 ISSN 2077 0383 PMC 8745413 PAGANINI EMIL P SUHOZA KAREN SWANN SAMUEL GOLDING LEONARD NAKAMOTO SATORU July 1986 Continuous Renal Replacement Therapy in Patients with Acute Renal Dysfunction Undergoing Intraaortic Balloon Pump and or Left Ventricular Device Support ASAIO Transactions 32 1 414 417 doi 10 1097 00002216 198609000 00005 ISSN 0889 7190 Samoni Sara Husain Syed Faeq Villa Gianluca Ronco Claudio 2021 12 29 Continuous Renal Replacement Therapy in the Critically Ill Patient From Garage Technology to Artificial Intelligence Journal of Clinical Medicine 11 1 172 doi 10 3390 jcm11010172 ISSN 2077 0383 PMC 8745413 Retrieved from https en wikipedia org w index php title Hemofiltration amp oldid 1193825994, wikipedia, wiki, book, books, library,

article

, read, download, free, free download, mp3, video, mp4, 3gp, jpg, jpeg, gif, png, picture, music, song, movie, book, game, games.