Degrees Brix (symbol °Bx) is a measure of the dissolved solids in a liquid, and is commonly used to measure dissolved sugar content of an aqueous solution.[1] One degree Brix is 1 gram of sucrose in 100 grams of solution and represents the strength of the solution as percentage by mass. If the solution contains dissolved solids other than pure sucrose, then the °Bx only approximates the dissolved solid content. For example, when one adds equal amounts of salt and sugar to equal amounts of water, the degrees of refraction (BRIX) of the salt solution rises faster than the sugar solution. The °Bx is traditionally used in the wine, sugar, carbonated beverage, fruit juice, fresh produce, maple syrup and honey industries. The °Bx is also used for measuring the concentration of a cutting fluid mixed in water for metalworking processes.

Measuring brix and percent acidity of a sudachi

Comparable scales for indicating sucrose content are: the Plato scale (°P), which is widely used by the brewing industry; the Oechsle scale used in German and Swiss wine making industries, amongst others; and the Balling scale, which is the oldest of the three systems and therefore mostly found in older textbooks, but is still in use in some parts of the world.[2]

A sucrose solution with an apparent specific gravity (20°/20 °C) of 1.040 would be 9.99325 °Bx or 9.99359 °P while the representative sugar body, the International Commission for Uniform Methods of Sugar Analysis (ICUMSA), which favours the use of mass fraction, would report the solution strength as 9.99249%. Because the differences between the systems are of little practical significance (the differences are less than the precision of most common instruments) and wide historical use of the Brix unit, modern instruments calculate mass fraction using ICUMSA official formulas but report the result as °Bx.

Background edit

In the early 1800s, Karl Balling, followed by Adolf Brix, and finally the Normal-Commissions under Fritz Plato, prepared pure sucrose solutions of known strength, measured their specific gravities and prepared tables of percent sucrose by mass vs. measured specific gravity. Balling measured specific gravity to 3 decimal places, Brix to 5, and the Normal-Eichungs Kommission to 6 with the goal of the Commission being to correct errors in the 5th and 6th decimal place in the Brix table.

Equipped with one of these tables, a brewer wishing to know how much sugar was in his wort could measure its specific gravity and enter that specific gravity into the Plato table to obtain °Plato, which is the concentration of sucrose by percentage mass. Similarly, a vintner could enter the specific gravity of his must into the Brix table to obtain the °Bx, which is the concentration of sucrose by percent mass. It is important to point out that neither wort nor must is a solution of pure sucrose in pure water. Many other compounds are dissolved as well but these are either sugars, which behave very similarly to sucrose with respect to specific gravity as a function of concentration, or compounds which are present in small amounts (minerals, hop acids in wort, tannins, acids in must). In any case, even if °Bx is not representative of the exact amount of sugar in a must or fruit juice, it can be used for comparison of relative sugar content.

Measurement edit

Specific gravity edit

As specific gravity was the basis for the Balling, Brix and Plato tables, dissolved sugar content was originally estimated by measurement of specific gravity using a hydrometer or pycnometer. In modern times, hydrometers are still widely used, but where greater accuracy is required, an electronic oscillating U-tube meter may be employed. Whichever means is used, the analyst enters the tables with specific gravity and takes out (using interpolation if necessary) the sugar content in percent by mass.

If the analyst uses the Plato tables (maintained by the American Society of Brewing Chemists[3]) they reports in °P. If using the Brix table (the current version of which is maintained by NIST and can be found on their website),[4] they reports in °Bx. If using the ICUMSA tables,[5] they would report in mass fraction (m.f.).

It is not, typically, actually necessary to consult tables as the tabulated °Bx or °P value can be printed directly on the hydrometer scale next to the tabulated value of specific gravity or stored in the memory of the electronic U-tube meter or calculated from polynomial fits to the tabulated data, in fact, the ICUMSA tables are calculated from a best-fit polynomial.

Also note that the tables in use today are not those published by Brix or Plato. Those workers measured true specific gravity reference to water at 4 °C using, respectively, 17.5 °C and 20 °C, as the temperature at which the density of a sucrose solution was measured. Both NBS and ASBC converted to apparent specific gravity at 20 °C/20 °C. The ICUMSA tables are based on more recent measurements on sucrose, fructose, glucose and invert sugar, and they tabulate true density and weight in air at 20 °C against mass fraction.

Refractive index edit

Dissolution of sucrose and other sugars in water changes not only its specific gravity but its optical properties, in particular its refractive index and the extent to which it rotates the plane of linearly polarized light. The refractive index, nD, for sucrose solutions of various percentage by mass has been measured and tables of nD vs. °Bx published. As with the hydrometer, it is possible to use these tables to calibrate a refractometer so that it reads directly in °Bx. Calibration is usually based on the ICUMSA tables,[6] but the user of an electronic refractometer should verify this.

Infrared absorption edit

Sugars also have known infrared absorption spectra and this has made it possible to develop instruments for measuring sugar concentration using mid-infrared (MIR), non-dispersive infrared (NDIR), and Fourier transform infrared (FT-IR) techniques. In-line instruments are available which allow constant monitoring of sugar content in sugar refineries, beverage plants, wineries, etc. As with any other instruments, MIR and FT-IR instruments can be calibrated against pure sucrose solutions and thus report in °Bx, but there are other possibilities with these technologies, as they have the potential to distinguish between sugars and interfering substances. Newer MIR and NDIR instruments have up to five analyzing channels that allow corrections for interference between ingredients.

Tables edit

Specific gravity edit

Approximate values of °Bx can be computed from 231.61 × (SG − 0.9977), where SG is the apparent specific gravity of the solution at 20 °C/20 °C. More accurate values are available from:

 ,

derived from the NBS table with SG as above. This should not be used above SG = 1.17874 (40 °Bx). RMS disagreement between the polynomial and the NBS table is 0.0009 °Bx.

The Plato scale can be approximated with a mean average error of less than 0.02°P with the following equation:[7]

 

or with even higher accuracy (average error less than 0.00053°P with respect to the ASBC tables) from the best-fit polynomial:[7]

 .

The difference between the °Bx and °P as calculated from the respective polynomials is:

 

The difference is generally less than ±0.0005 °Bx or °P with the exception being for weak solutions. As 0 °Bx is approached °P tend towards as much as 0.002 °P higher than the °Bx calculated for the same specific gravity. Disagreements of this order of magnitude can be expected as the NBS and the ASBC used slightly different values for the density of air and pure water in their calculations for converting to apparent specific gravity. It should be clear from these comments that Plato and Brix are, for all but the most exacting applications, the same. Note: all polynomials in this article are in a format that can be pasted directly into a spreadsheet.

The ICUMSA polynomials are generally only published in the form where mass fraction is used to derive the density. As a result, they are omitted from this section.

Refractive index edit

When a refractometer is used, the Brix value can be obtained from the polynomial fit to the ICUMSA table:

 ,

where   is the refractive index measured at the wavelength of the sodium D line (589.3 nm) at 20 °C. Temperature is very important as refractive index changes dramatically with temperature. Many refractometers have built in "Automatic Temperature Compensation" (ATC) which is based on knowledge of the way the refractive index of sucrose changes. For example, the refractive index of a sucrose solution of strength less than 10 °Bx is such that a 1 °C change in temperature would cause the Brix reading to shift by about 0.06 °Bx. Beer, conversely, exhibits a change with temperature about three times this much. It is important, therefore, that users of refractometers either make sure the sample and prism of the instrument are both at very close to 20 °C or, if that is difficult to ensure, readings should be taken at 2 temperatures separated by a few degrees, the change per degree noted and the final recorded value referenced to 20 °C using the Bx vs. Temp slope information.

As solutes other than sucrose may affect the refractive index and the specific gravity differently, this refractive "Brix" value is not interchangeable with the traditional hydrometer Brix unless corrections are applied. The formal term for such a refractive value is "Refractometric Dry Substance" (RDS). See § Brix and actual dissolved solids content below.

Usage edit

The four scales are often used interchangeably since the differences are minor.

Brix is used in the food industry for measuring the approximate amount of sugars in fruits, vegetables, juices, wine, soft drinks and in the starch and sugar manufacturing industry. Different countries use the scales in different industries: In brewing, the UK uses specific gravity X 1000; Europe uses Plato degrees; and the US use a mix of specific gravity, degrees Brix, degrees Baumé, and degrees Plato. For fruit juices, 1.0 degree Brix is denoted as 1.0% sugar by mass. This usually correlates well with perceived sweetness.

Modern optical Brix meters are divided into two categories. In the first are the Abbe-based instruments in which a drop of the sample solution is placed on a prism; the result is observed through an eyepiece. The critical angle (the angle beyond which light is totally reflected back into the sample) is a function of the refractive index and the operator detects this critical angle by noting where a dark-bright boundary falls on an engraved scale. The scale can be calibrated in Brix or refractive index. Often the prism mount contains a thermometer which can be used to correct to 20 °C in situations where measurement cannot be made at exactly that temperature. These instruments are available in bench and handheld versions.

Digital refractometers also find the critical angle, but the light path is entirely internal to the prism. A drop of sample is placed on its surface, so the critical light beam never penetrates the sample. This makes it easier to read turbid samples. The light/dark boundary, whose position is proportional to the critical angle, is sensed by a CCD array. These meters are also available in bench top (laboratory) and portable (pocket) versions. This ability to easily measure Brix in the field makes it possible to determine ideal harvesting times of fruit and vegetables so that products arrive at the consumers in a perfect state or are ideal for subsequent processing steps such as vinification.

Due to higher accuracy and the ability to couple it with other measuring techniques (%CO2 and %alcohol), most soft drink companies and breweries use an oscillating U-tube density meter. Refractometers are still commonly used for fruit juice.

Brix and actual dissolved solids content edit

When a sugar solution is measured by refractometer or density meter, the °Bx or °P value obtained by entry into the appropriate table only represents the amount of dry solids dissolved in the sample if the dry solids are exclusively sucrose. This is seldom the case. Grape juice (must), for example, contains little sucrose but does contain glucose, fructose, acids, and other substances. In such cases, the °Bx value clearly cannot be equated with the sucrose content, but it may represent a good approximation to the total sugar content. For example, an 11.0% by mass D-Glucose ("grape sugar") solution measured 10.9 °Bx using a hand held instrument.[citation needed] For these reasons, the sugar content of a solution obtained by use of refractometry with the ICUMSA table is often reported as "Refractometric Dry Substance" (RDS)[8] which could be thought of as an equivalent sucrose content. Where it is desirable to know the actual dry solids content, empirical correction formulas can be developed based on calibrations with solutions similar to those being tested. For example, in sugar refining, dissolved solids can be accurately estimated from refractive index measurement corrected by an optical rotation (polarization) measurement.[9]

Alcohol has a higher refractive index (1.361) than water (1.333). As a consequence, a refractometer measurement made on a sugar solution once fermentation has begun will result in a reading substantially higher than the actual solids content. Thus, an operator must be certain that the sample they are testing has not begun to ferment. (If fermentation has indeed started, a correction can be made by estimating alcohol concentration from the original, pre-fermentation reading, termed "OG" by homebrewers.)[10] Brix or Plato measurements based on specific gravity are also affected by fermentation, but in the opposite direction; as ethanol is less dense than water, an ethanol/sugar/water solution gives a Brix or Plato reading which is artificially low.

References edit

  1. ^ "Definition of brix".
  2. ^ Hough, J.S., D. E. Briggs, R. Stevens and T. W. Young, Malting and Brewing Science, Vol 2 Hopped Wort and Beer, Chapman & Hall, London,1971
  3. ^ "ASBC Methods of Analysis", ASBC; St. Paul Table 1: Extract in Wort and Beer
  4. ^ Bates, Frederick (1 May 1942). "Polarimetry, Saccharimetry and the Sugars. Table 114: Brix, apparent density, apparent specific gravity, and grams of sucrose per 100 ml of sugar solutions". National Bureau of Standards. p. 632. Retrieved 12 October 2018.
  5. ^ "ICUMSA Methods Book" op. cit. Specification and Standard SPS-4 Densimitry and Tables: Sucrose – Official; Glucose, Fructose and Invert Sugars – Official
  6. ^ "ICUMSA Methods Book", op. cit.; Specification and Standard SPS-3 Refractometry and Tables – Official; Tables A-F
  7. ^ a b Buhl, Josh. "Physical Equations Relating Extract and Relative Density". OSF Preprints. Center for Open Science. Retrieved 13 October 2023.
  8. ^ "ICUMSA Methods Book, op. cit. Method GS4/3/8-13 (2009) "The Determination of Refractometric Dry Substance (RDS %) of Molasses – Accepted and Very Pure Syrups (Liquid Sugars), Thick Juice and Run-off Syrups – Official"
  9. ^ Sgualdino, G.; Vaccari, G.; Mantovani, G. (1982). "Conversion of refractometric dry substance into real dry substance for quentin molasses [Sugar syrups]". Journal of the American Society of Sugar Beet Technologists (USA). ISSN 0003-1216.
  10. ^ "Using your Refractometer Correctly for Maximum Accuracy in Home Brewing - Brewer's Friend". Brewer's Friend. 24 April 2013.

Further reading edit

  • Boulton, Roger; Vernon Singleton; Linda Bisson; Ralph Kunkee (1996). Principles and Practices of Winemaking. Chapman & Hall. ISBN 0-412-06411-1
  • Robert O'Leary BevSense LLC. "Testing Brix and Acid In-Line for the Beverage Industry" (PDF). – O'Leary describes the theory and practice of measuring brix on-line in beverages.
  • Combined laboratory systems for measuring Brix and CO2 in soft drinks and Plato, CO2, % alcohol, pH, and color in beer are available. They can exist both in a lab as a benchtop unit, and also directly in the production piping as an inline unit.

External links edit

  • Brix, Specific Gravity & Sugar Conversions

brix, other, uses, disambiguation, degrees, symbol, measure, dissolved, solids, liquid, commonly, used, measure, dissolved, sugar, content, aqueous, solution, degree, gram, sucrose, grams, solution, represents, strength, solution, percentage, mass, solution, c. For other uses see Brix disambiguation Degrees Brix symbol Bx is a measure of the dissolved solids in a liquid and is commonly used to measure dissolved sugar content of an aqueous solution 1 One degree Brix is 1 gram of sucrose in 100 grams of solution and represents the strength of the solution as percentage by mass If the solution contains dissolved solids other than pure sucrose then the Bx only approximates the dissolved solid content For example when one adds equal amounts of salt and sugar to equal amounts of water the degrees of refraction BRIX of the salt solution rises faster than the sugar solution The Bx is traditionally used in the wine sugar carbonated beverage fruit juice fresh produce maple syrup and honey industries The Bx is also used for measuring the concentration of a cutting fluid mixed in water for metalworking processes Measuring brix and percent acidity of a sudachiComparable scales for indicating sucrose content are the Plato scale P which is widely used by the brewing industry the Oechsle scale used in German and Swiss wine making industries amongst others and the Balling scale which is the oldest of the three systems and therefore mostly found in older textbooks but is still in use in some parts of the world 2 A sucrose solution with an apparent specific gravity 20 20 C of 1 040 would be 9 99325 Bx or 9 99359 P while the representative sugar body the International Commission for Uniform Methods of Sugar Analysis ICUMSA which favours the use of mass fraction would report the solution strength as 9 99249 Because the differences between the systems are of little practical significance the differences are less than the precision of most common instruments and wide historical use of the Brix unit modern instruments calculate mass fraction using ICUMSA official formulas but report the result as Bx Contents 1 Background 2 Measurement 2 1 Specific gravity 2 2 Refractive index 2 3 Infrared absorption 3 Tables 3 1 Specific gravity 3 2 Refractive index 4 Usage 5 Brix and actual dissolved solids content 6 References 7 Further reading 8 External linksBackground editIn the early 1800s Karl Balling followed by Adolf Brix and finally the Normal Commissions under Fritz Plato prepared pure sucrose solutions of known strength measured their specific gravities and prepared tables of percent sucrose by mass vs measured specific gravity Balling measured specific gravity to 3 decimal places Brix to 5 and the Normal Eichungs Kommission to 6 with the goal of the Commission being to correct errors in the 5th and 6th decimal place in the Brix table Equipped with one of these tables a brewer wishing to know how much sugar was in his wort could measure its specific gravity and enter that specific gravity into the Plato table to obtain Plato which is the concentration of sucrose by percentage mass Similarly a vintner could enter the specific gravity of his must into the Brix table to obtain the Bx which is the concentration of sucrose by percent mass It is important to point out that neither wort nor must is a solution of pure sucrose in pure water Many other compounds are dissolved as well but these are either sugars which behave very similarly to sucrose with respect to specific gravity as a function of concentration or compounds which are present in small amounts minerals hop acids in wort tannins acids in must In any case even if Bx is not representative of the exact amount of sugar in a must or fruit juice it can be used for comparison of relative sugar content Measurement editSpecific gravity edit As specific gravity was the basis for the Balling Brix and Plato tables dissolved sugar content was originally estimated by measurement of specific gravity using a hydrometer or pycnometer In modern times hydrometers are still widely used but where greater accuracy is required an electronic oscillating U tube meter may be employed Whichever means is used the analyst enters the tables with specific gravity and takes out using interpolation if necessary the sugar content in percent by mass If the analyst uses the Plato tables maintained by the American Society of Brewing Chemists 3 they reports in P If using the Brix table the current version of which is maintained by NIST and can be found on their website 4 they reports in Bx If using the ICUMSA tables 5 they would report in mass fraction m f It is not typically actually necessary to consult tables as the tabulated Bx or P value can be printed directly on the hydrometer scale next to the tabulated value of specific gravity or stored in the memory of the electronic U tube meter or calculated from polynomial fits to the tabulated data in fact the ICUMSA tables are calculated from a best fit polynomial Also note that the tables in use today are not those published by Brix or Plato Those workers measured true specific gravity reference to water at 4 C using respectively 17 5 C and 20 C as the temperature at which the density of a sucrose solution was measured Both NBS and ASBC converted to apparent specific gravity at 20 C 20 C The ICUMSA tables are based on more recent measurements on sucrose fructose glucose and invert sugar and they tabulate true density and weight in air at 20 C against mass fraction Refractive index edit Dissolution of sucrose and other sugars in water changes not only its specific gravity but its optical properties in particular its refractive index and the extent to which it rotates the plane of linearly polarized light The refractive index nD for sucrose solutions of various percentage by mass has been measured and tables of nD vs Bx published As with the hydrometer it is possible to use these tables to calibrate a refractometer so that it reads directly in Bx Calibration is usually based on the ICUMSA tables 6 but the user of an electronic refractometer should verify this Infrared absorption edit Sugars also have known infrared absorption spectra and this has made it possible to develop instruments for measuring sugar concentration using mid infrared MIR non dispersive infrared NDIR and Fourier transform infrared FT IR techniques In line instruments are available which allow constant monitoring of sugar content in sugar refineries beverage plants wineries etc As with any other instruments MIR and FT IR instruments can be calibrated against pure sucrose solutions and thus report in Bx but there are other possibilities with these technologies as they have the potential to distinguish between sugars and interfering substances Newer MIR and NDIR instruments have up to five analyzing channels that allow corrections for interference between ingredients Tables editSpecific gravity edit Approximate values of Bx can be computed from 231 61 SG 0 9977 where SG is the apparent specific gravity of the solution at 20 C 20 C More accurate values are available from B x 182 4601 S G 3 775 6821 S G 2 1262 7794 S G 669 5622 displaystyle circ Bx 182 4601 SG 3 775 6821 SG 2 1262 7794 SG 669 5622 nbsp derived from the NBS table with SG as above This should not be used above SG 1 17874 40 Bx RMS disagreement between the polynomial and the NBS table is 0 0009 Bx The Plato scale can be approximated with a mean average error of less than 0 02 P with the following equation 7 P 260 4 260 4 S G displaystyle circ P 260 4 frac 260 4 SG nbsp or with even higher accuracy average error less than 0 00053 P with respect to the ASBC tables from the best fit polynomial 7 P 133 5892 S G 3 622 5576 S G 2 1102 9079 S G 613 9427 displaystyle circ P 133 5892 SG 3 622 5576 SG 2 1102 9079 SG 613 9427 nbsp The difference between the Bx and P as calculated from the respective polynomials is P B x 48 8709 S G 3 133 1245 S G 2 159 8715 S G 55 6195 displaystyle circ P circ Bx 48 8709 SG 3 133 1245 SG 2 159 8715 SG 55 6195 nbsp The difference is generally less than 0 0005 Bx or P with the exception being for weak solutions As 0 Bx is approached P tend towards as much as 0 002 P higher than the Bx calculated for the same specific gravity Disagreements of this order of magnitude can be expected as the NBS and the ASBC used slightly different values for the density of air and pure water in their calculations for converting to apparent specific gravity It should be clear from these comments that Plato and Brix are for all but the most exacting applications the same Note all polynomials in this article are in a format that can be pasted directly into a spreadsheet The ICUMSA polynomials are generally only published in the form where mass fraction is used to derive the density As a result they are omitted from this section Refractive index edit When a refractometer is used the Brix value can be obtained from the polynomial fit to the ICUMSA table B x 11758 74 n D 5 88885 21 n D 4 270177 93 n D 3 413145 80 n D 2 318417 95 n D 99127 4536 displaystyle circ Bx 11758 74n D 5 88885 21n D 4 270177 93n D 3 413145 80n D 2 318417 95n D 99127 4536 nbsp where n D displaystyle n D nbsp is the refractive index measured at the wavelength of the sodium D line 589 3 nm at 20 C Temperature is very important as refractive index changes dramatically with temperature Many refractometers have built in Automatic Temperature Compensation ATC which is based on knowledge of the way the refractive index of sucrose changes For example the refractive index of a sucrose solution of strength less than 10 Bx is such that a 1 C change in temperature would cause the Brix reading to shift by about 0 06 Bx Beer conversely exhibits a change with temperature about three times this much It is important therefore that users of refractometers either make sure the sample and prism of the instrument are both at very close to 20 C or if that is difficult to ensure readings should be taken at 2 temperatures separated by a few degrees the change per degree noted and the final recorded value referenced to 20 C using the Bx vs Temp slope information As solutes other than sucrose may affect the refractive index and the specific gravity differently this refractive Brix value is not interchangeable with the traditional hydrometer Brix unless corrections are applied The formal term for such a refractive value is Refractometric Dry Substance RDS See Brix and actual dissolved solids content below Usage editSee also Ripeness in viticulture The four scales are often used interchangeably since the differences are minor Brix is primarily used in fruit juice wine making carbonated beverage industry starch and the sugar industry Plato is primarily used in brewing Balling appears on older saccharimeters and is still used in the South African wine industry and in some breweries Oechsle as direct reading for the sugar content is primary used in wine making in Germany Switzerland and Luxembourg Brix is used in the food industry for measuring the approximate amount of sugars in fruits vegetables juices wine soft drinks and in the starch and sugar manufacturing industry Different countries use the scales in different industries In brewing the UK uses specific gravity X 1000 Europe uses Plato degrees and the US use a mix of specific gravity degrees Brix degrees Baume and degrees Plato For fruit juices 1 0 degree Brix is denoted as 1 0 sugar by mass This usually correlates well with perceived sweetness Modern optical Brix meters are divided into two categories In the first are the Abbe based instruments in which a drop of the sample solution is placed on a prism the result is observed through an eyepiece The critical angle the angle beyond which light is totally reflected back into the sample is a function of the refractive index and the operator detects this critical angle by noting where a dark bright boundary falls on an engraved scale The scale can be calibrated in Brix or refractive index Often the prism mount contains a thermometer which can be used to correct to 20 C in situations where measurement cannot be made at exactly that temperature These instruments are available in bench and handheld versions Digital refractometers also find the critical angle but the light path is entirely internal to the prism A drop of sample is placed on its surface so the critical light beam never penetrates the sample This makes it easier to read turbid samples The light dark boundary whose position is proportional to the critical angle is sensed by a CCD array These meters are also available in bench top laboratory and portable pocket versions This ability to easily measure Brix in the field makes it possible to determine ideal harvesting times of fruit and vegetables so that products arrive at the consumers in a perfect state or are ideal for subsequent processing steps such as vinification Due to higher accuracy and the ability to couple it with other measuring techniques CO2 and alcohol most soft drink companies and breweries use an oscillating U tube density meter Refractometers are still commonly used for fruit juice Brix and actual dissolved solids content editWhen a sugar solution is measured by refractometer or density meter the Bx or P value obtained by entry into the appropriate table only represents the amount of dry solids dissolved in the sample if the dry solids are exclusively sucrose This is seldom the case Grape juice must for example contains little sucrose but does contain glucose fructose acids and other substances In such cases the Bx value clearly cannot be equated with the sucrose content but it may represent a good approximation to the total sugar content For example an 11 0 by mass D Glucose grape sugar solution measured 10 9 Bx using a hand held instrument citation needed For these reasons the sugar content of a solution obtained by use of refractometry with the ICUMSA table is often reported as Refractometric Dry Substance RDS 8 which could be thought of as an equivalent sucrose content Where it is desirable to know the actual dry solids content empirical correction formulas can be developed based on calibrations with solutions similar to those being tested For example in sugar refining dissolved solids can be accurately estimated from refractive index measurement corrected by an optical rotation polarization measurement 9 Alcohol has a higher refractive index 1 361 than water 1 333 As a consequence a refractometer measurement made on a sugar solution once fermentation has begun will result in a reading substantially higher than the actual solids content Thus an operator must be certain that the sample they are testing has not begun to ferment If fermentation has indeed started a correction can be made by estimating alcohol concentration from the original pre fermentation reading termed OG by homebrewers 10 Brix or Plato measurements based on specific gravity are also affected by fermentation but in the opposite direction as ethanol is less dense than water an ethanol sugar water solution gives a Brix or Plato reading which is artificially low References edit Definition of brix Hough J S D E Briggs R Stevens and T W Young Malting and Brewing Science Vol 2 Hopped Wort and Beer Chapman amp Hall London 1971 ASBC Methods of Analysis ASBC St Paul Table 1 Extract in Wort and Beer Bates Frederick 1 May 1942 Polarimetry Saccharimetry and the Sugars Table 114 Brix apparent density apparent specific gravity and grams of sucrose per 100 ml of sugar solutions National Bureau of Standards p 632 Retrieved 12 October 2018 ICUMSA Methods Book op cit Specification and Standard SPS 4 Densimitry and Tables Sucrose Official Glucose Fructose and Invert Sugars Official ICUMSA Methods Book op cit Specification and Standard SPS 3 Refractometry and Tables Official Tables A F a b Buhl Josh Physical Equations Relating Extract and Relative Density OSF Preprints Center for Open Science Retrieved 13 October 2023 ICUMSA Methods Book op cit Method GS4 3 8 13 2009 The Determination of Refractometric Dry Substance RDS of Molasses Accepted and Very Pure Syrups Liquid Sugars Thick Juice and Run off Syrups Official Sgualdino G Vaccari G Mantovani G 1982 Conversion of refractometric dry substance into real dry substance for quentin molasses Sugar syrups Journal of the American Society of Sugar Beet Technologists USA ISSN 0003 1216 Using your Refractometer Correctly for Maximum Accuracy in Home Brewing Brewer s Friend Brewer s Friend 24 April 2013 Further reading editBoulton Roger Vernon Singleton Linda Bisson Ralph Kunkee 1996 Principles and Practices of Winemaking Chapman amp Hall ISBN 0 412 06411 1 Robert O Leary BevSense LLC Testing Brix and Acid In Line for the Beverage Industry PDF O Leary describes the theory and practice of measuring brix on line in beverages Combined laboratory systems for measuring Brix and CO2 in soft drinks and Plato CO2 alcohol pH and color in beer are available They can exist both in a lab as a benchtop unit and also directly in the production piping as an inline unit External links editBrix to Specific Gravity Table Brix Specific Gravity amp Sugar Conversions Brix Plato Balling Specific gravity Retrieved from https en wikipedia org w index php title Brix amp oldid 1191529756, wikipedia, wiki, book, books, library,